Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “diode effects”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Fast-Charging Li 4 Ti 5 O 12 Anode Driven by Light

Lithium-ion batteries with fast charging capabilities are crucial for widespread adoption of electric vehicles, as they will increase acceptance of the technology and reduce range anxiety for drivers. To achieve this, advanced fast charging technologies and alternative methods to enhance the slow electrochemical processes are desperately required. This study applied light-emitting diode (LED) photo-assisted fast charging to Li 4 Ti 5 O 12 (LTO), a large bandgap cubic spinel material, to enhance charging speed through electronic-structure coupling. UV LED-generated light irradiation on to the electrode interface boosted the ion diffusion and lithium cation addition by a factor of 1.3 during electrochemical lithiation, resulting in a 30% decrease in charging time under ambient conditions. Red LED light was not effective in accelerating the reaction as it does not provide sufficient energy. The first-principles calculations support the concept that UV illumination generates charges by overcoming the material’s bandgap and effectively reducing it through the introduction of additional titanium defect states.

25 ENERGY STORAGE↗

High data rate optical transceiver terminal

The objectives of this study were: (1) to design a 400 Mbps optical transceiver terminal to operate from a high-altitude balloon-borne platform in order to permit the quantitative evaluation of a space-qualifiable optical communications system design, (2) to design an atmospheric propagation experiment to operate in conjunction with the terminal to measure the degrading effects of the atmosphere on the links, and (3) to design typical optical communications experiments for space-borne laboratories in the 1980-1990 time frame. As a result of the study, a transceiver package has been configured for demonstration flights during late 1974. The transceiver contains a 400 Mbps transmitter, a 400 Mbps receiver, and acquisition and tracking receivers. The transmitter is a Nd:YAG, 200 Mhz, mode-locked, CW, diode-pumped laser operating at 1.06 um requiring 50 mW for 6 db margin. It will be designed to implement Pulse Quaternary Modulation (PQM). The 400 Mbps receiver utilizes a Dynamic Crossed-Field Photomultiplier (DCFP) detector. The acquisition receiver is a Quadrant Photomultiplier Tube (QPMT) and receives a 400 Mbps signal chopped at 0.1 Mhz.

Clarke, E. S.↗

Computing in the presence of soft bit errors

It is shown that single-event-upsets (SEUs) due to cosmic rays are a significant source of single bit error in spacecraft computers. The physical mechanism of SEU, electron hole generation by means of Linear Energy Transfer (LET), it discussed with reference made to the results of a study of the environmental effects on computer systems of the Galileo spacecraft. Techniques for making software more tolerant of cosmic ray effects are considered, including: reducing the number of registers used by the software; continuity testing of variables; redundant execution of major procedures for error detection; and encoding state variables to detect single-bit changes. Attention is also given to design modifications which may reduce the cosmic ray exposure of on-board hardware. These modifications include: shielding components operating in LEO; removing low-power Schottky parts; and the use of CMOS diodes. The SEU parameters of different electronic components are listed in a table.

Rasmussen, R. D.↗

Digital angular position sensor using wavelength division multiplexing

Future aircraft will use fly-by-light control systems with fiber-linked optical sensors for such measurands as temperature, pressure, and linear and angular position. A digital optical sensor is described which was developed to transmit the angular position of such slowly rotating parts as a throttle of fuel flow control valve on an aircraft. The sensor employs a reflective code plate with ten channels providing a resolution of 0.35 degrees. Two light-emitting diodes with overlapping spectra are used as light sources. A single microoptic multiplexer-demultiplexer composed of a GRIN rod lens and a miniature grating is used to disperse the spectrum and recombine the spectral components from each channel after reflection by the code plate. The results of preliminary environmental tests of this unit are discussed. The sensor has been operated for brief periods of time between -60 C and +125 without adverse effects. Preliminary vibration tests indicate that the unit will work properly at the maximum vibration levels expected in a jet-engine environment.

Fritsch, Klaus↗

Simulation and ground testing with the Advanced Video Guidance Sensor

The Advanced Video Guidance Sensor (AVGS), an active sensor system that provides near-range 6-degree-of-freedom sensor data, has been developed as part of an automatic rendezvous and docking system for the Demonstration of Autonomous Rendezvous Technology (DART). The sensor determines the relative positions and attitudes between the active sensor and the passive target at ranges up to 300 meters. The AVGS uses laser diodes to illuminate retro-reflectors in the target, a solid-state imager to detect the light returned from the target, and image capture electronics and a digital signal processor to convert the video information into the relative positions and attitudes. The development of the sensor, through initial prototypes, final prototypes, and three flight units, has required a great deal of testing at every phase, and the different types of testing, their effectiveness, and their results, are presented in this paper, focusing on the testing of the flight units. Testing has improved the sensor's performance.

Howard, Richard T.↗

Increased magnetic damping of a single domain wall and adjacent magnetic domains detected by spin torque diode in a nanostripe

Spin torque resonance has been used to simultaneously probe the dynamics of a magnetic domain wall and of magnetic domains in a nanostripe magnetic tunnel junction. Due to the large associated resistance variations, we are able to analyze quantitatively the resonant properties of these single nanoscale magnetic objects. In particular, we find that the magnetic damping of both the domains and the domain wall is doubled compared to the damping value of the host magnetic layer. We estimate the contributions to the damping arising from the dipolar couplings between the different layers in the junction and from the intralayer spin pumping effect, and find that they cannot explain the large damping enhancement that we observe. We conclude that the measured increased damping is intrinsic to large amplitudes excitations of spatially localized modes or solitons such as vibrating or propagating domain walls.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Direct observation of electric field-induced magnetism in a molecular magnet

Abstract We report the direct observation of an electrically-induced magnetic susceptibility in the molecular nano- magnet [Fe 3 O(O 2 CPh) 6 (py) 3 ]ClO 4 · py, an Fe 3 trimer. This magnetoelectric effect results from the breaking of spatial inversion symmetry due to the spin configurations of the antiferromagnetic trimer. Both static and very low frequency electric fields were used. Fractional changes of the magnetic susceptibility of 11 ppb $$\pm 2$$ ± 2 per kVm -1 for the temperature range 8 . 5 < T < 13 . 5 K were observed for applied electric fields up to 62 kV m − 1 . The changes in susceptibility were measured using a tunnel diode oscillator operating at liquid helium temperatures while the sample is held at a higher regulated temperature.

30 DIRECT ENERGY CONVERSION↗

Fast External Quantum Efficiency Measurements of Photovoltaic Modules

The external quantum efficiency (EQE) or associated spectral response is widely used to evaluate the performance of photovoltaics, light emitting diodes, photodetectors, photodiodes, semiconductor lasers, laser-induced refrigeration of solids etc. For photovoltaic (PV) devices, The EQE is used to determine the spectral mismatch correction that is used to convert a performance measurement from a non-ideal simulator spectrum to a standard spectrum in PV device calibrations. Moreover, EQE can provide important insight into the physics of a PV device. For instance, the EQE shape can be used to infer mechanisms limiting the performance of the device. However, EQE measurements of full-size PV modules remain a challenge in the PV community due to rare availability of reliable module QE measurement tools worldwide and the size and complexity of module architecture that comprises several cells connected in strings (series or/and parallel). Here, we use a customized nondestructive tool made of high-power light emitting diodes to perform high-throughput EQE measurements on PV modules. Circuit simulations show that the measurement system can safely be used to measure both crystalline silicon and thin film-based PV modules with series connected cells without the risk of damage through reverse bias. In addition, EQE mapping combined with electroluminescence show a strong correlation and provide a way to determine both spatial non-uniformity of the spectral response and defects/degradation effects across the module.

PV module↗

SU-E-T-601: Output Factor Calculation of Irregular Shape Electron Cutout at Extended SSD

Purpose: To calculate the output factor of irregular shape electron beam at extended SSD using modified lateral build-up-ratio method. Methods: Circular cutouts from 2.0cm diameter to maximum possible sizes were prepared for applicator cone size of 15×15cm. In addition, different irregular cutouts were prepared. Percentage depth dose (PDD) curves were measured for each cutout using 6, 9, 12 and 16-MeV at the standard SSD of 100cm. The scanning was done using Multidata system and Scanditronix diodes on 2100SC Varian LINAC. In addition, for each cutout and electron beam energy doses were measured at SSD values of 100, 105, 110, 115cm using EDR2 films and diodes. Results: The measured PDD were normalized to the depth of 1.0mm. The lateral build-up-ratio (LBR) and the lateral scatter parameter (sigma) were calculated for each circular cutout using the open 15X15-cm2 field as the reference field. Taking the linear increase of sigma with cutout size into account, PDD of the irregular cutouts were calculated at 100 cm SSD. Furthermore, using the dose measured at different SSDs, the effective SSD value for each circular cutout and electron beam energy was determined. Employing the LBR and the effective-SSD values of the circular cutouts along with the calculated PDD of the irregular cutouts, the output factors of the irregular cutout at different extended SSD values were calculated. Finally, the calculated output factors were compared with the measured values. Conclusion: In this research, it is shown that output factor of irregular shape electron beam at extended SSD can be determined by using the LBR and the effective SSD values of circular cutouts. The percentage difference of the calculated output factor from the measured output factor for irregular cutouts at extended SSD were within 3.0%.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-388: Evaluation of Electronic Brachytherapy Dose Distributions in Tissue Equivalent Materials

Purpose: To study the measured and calculated dose distributions for electronic brachytherapy (EBT) in various tissue equivalent homogenous materials. Methods: Calculated dose distributions in water were generated using published TG-43 parameters in Varian BrachyVision software for a 50 kVp, 50 cm Xoft source. Dose distributions were measured within a 3D-scanning tank using dosimeters including: PTW 0.125 cc, pin-point, and parallel-plate ion chambers, Sun Nuclear “Edge” diode and Gafchromic EBT3 film. Multi-channel film dosimetry was used in film analysis. EBT3 film curves were calibrated via radial dose comparison to both independently measured and published data. The resulting film calibration was utilized to measure dose distributions created by titanium filtered source utilized in clinical brachytherapy applications. Data was collected within homogenous PMMA, vinyl, polystyrene, paraffin, and water-equivalent plastic phantoms. Results: Ion-chamber data was corrected to effective points of measurement and normalized prior to comparison between calculated and measured dose distributions. Measurements made in water and water equivalent materials compared well with results from treatment planning software. The maximum percent differences (relative to water) observed between 1 cm and 3.5 cm depth from source for each of the phantom materials are as follows: PMMA 35%, polystyrene 41%, plastic-water 23%, vinyl 115%, and paraffin 46%. Conclusion: The increased probability of photoelectric interactions occurring within the patient during electronic brachytherapy will emphasize the radiological differences between varying human tissues in dose deposition. These differences can Result in clinically significant dose perturbations and it is therefore recommended to move to a model based dose calculation, as outlined in TG-186, to improve the dosimetric accuracy of low energy EBT.

60 APPLIED LIFE SCIENCES↗

Nitrogen soft and hard X-ray emissions using different shapes of anodes in a 4-kJ plasma focus device

The effect of different anode tip geometries on the intensity of soft and hard X-rays emitted from a 4-kJ plasma focus device is investigated using five different anode tips. The shapes of the uppermost region of these anodes (tips) have been cylindrical-flat, cylindrical-hollow, spherical-convex, cone-flat, and cone-hollow. For time-resolved measurement of the emitted X-rays, several BPX-65 pin diodes covered by different filters and a fast plastic scintillator are used. Experimental results have shown that, the highest intensity of the both soft and hard X-ray is recorded in cone-flat, spherical-convex, and cone-hollow tips, respectively. The use of cone-flat anode tip has augmented the emitted X-ray three times.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Observation of Undulator Radiation Generated by a Single Electron Circulating in a Storage Ring and Possible Applications

An experimental study into the undulator radiation, generated by a single electron was carried out at the Integrable Optics Test Accelerator (IOTA) storage ring at Fermilab. The individual photons were detected by a Single Photon Avalanche Diode (SPAD) at an average rate of 1 detection per 300 revolutions in the ring. The detection events were continuously recorded by a picosecond event timer for as long as 1 minute at a time. The collected data were used to test if there is any deviation from the classically predicted Poissonian photostatistics. It was motivated by the observation * of sub-Poissonian statistics in a similar experiment. The observation * could be an instrumentation effect related to low detection efficiency and long detector dead time. In our experiment, the detector (SPAD) has a much higher efficiency (65%) and a much lower dead time. In addition, we show that the collected data (recorded detection times) can be used to study the synchrotron motion of a single electron and infer some parameters of the ring. For example, by comparing the results of simulation and measurement for the synchrotron motion we were able to estimate the magnitude of the RF phase jitter.

43 PARTICLE ACCELERATORS↗

Arrangement for damping the resonance in a laser diode

An arrangement for damping the resonance in a laser diode is described. This arrangement includes an additional layer which together with the conventional laser diode form a structure (35) of a bipolar transistor. Therein, the additional layer serves as the collector, the cladding layer next to it as the base, and the active region and the other cladding layer as the emitter. A capacitor is connected across the base and the collector. It is chosen so that at any frequency above a certain selected frequency which is far below the resonance frequency the capacitor impedance is very low, effectively shorting the base to the collector.

Katz, J.↗

Solar Array System Combined Environmental Effects Tests: Gateway Power and Propulsion Element

The NASA Lunar Orbital Platform-Gateway (LOP-G), a vital component of NASA’s Artemis program, will serve as a multi-purpose outpost orbiting the Moon. A foundational component of LOP-G is the Power and Propulsion Element (PPE). The PPE is a high-power, +60-kilowatt solar electric propulsion spacecraft that will provide power, high-rate communications, attitude control, and orbital transfer capabilities for the Gateway. The solar array system will utilize 4-junction photovoltaic cell technology on a flexible substrate (roll-out solar array or ROSA) in combination with multiple diode assemblies to combine the power of the solar array strings. NASA’s Marshall Space Flight Center, together with the PPE developer, Maxar, are in the midst of completing a rigorous combined environments test campaign of 3 solar array coupons and 1 array blocking diode board coupon. The campaign includes Ultra-Violet Radiation, Charged Particle Radiation, Ion Erosion, Thermal Cycles, and Electrostatic Discharge tests. The environments are applied in 3 separate incremental stages reflecting the various mission phases: 460 days of Earth-to-Lunar Transit, with much of that time through the Van Allen Belts, 5-years in Lunar Near-Rectilinear Halo Orbit (NRHO) at the Moon, and finally 15-years in Lunar NRHO, which represents the end of the design life. This paper will report on the state of the testing for each coupon, and brief look at the array performance, including some unexpected sensitivities of array blocking diodes.

Gateway↗

Development of Fast-Pulse Neutron Generation Capability by Beam-Target Interaction on HERMES-III for Radiation Effects Testing (Final Report)

The goal of this project is to produce an intense neutron pulse on HERMES III using the beam-target method with an intense proton beam. The potential advantage of proton use is that the generated neutron spectrum contains significantly more high-energy neutrons than that produced by electron-beam generated photoneutrons using the same facility. And compared to (D,T) facilities such as NIF, no tritium (or deuterium) is required for this process. To achieve the mid ~10 10 neutrons/cm 2 at a test object location listed as the goal in the Proposal, it was proposed that a radial ion diode previously developed and fielded at the 6 MeV - level be extended in performance to the full-power level on HERMES, with proton energies in the neighborhood of 15 MeV. This Report details the successful development of the radial ion diode at full power, which required more durable hardware which could be fielded at a one shot/day basis with minimal debris and activation (an important concern), and which could be substituted quickly into the normal negative-polarity bremsstrahlung source experiments without compromising the main HERMES validation mission. As direct measurement of proton beam characteristics proved challenging, the Project relied on an extensive series of simulations, LSP for beam dynamics and MCNP to characterize neutron output. Simulation results will be discussed, including the conclusion that neutron measurements made are consistent with an MCNP-predicted proton beam of 16 MeV peak energy, and 200 kA peak current. This Project also contributes to physics understanding of the use of inductive voltage adder (IVA) platforms to drive diode loads. Since such diodes operate independently of the physics of IVAs, the IVA-diode coupling requires matching of the MITL flow to the requirements of ion diode operation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Photochemical Internalization of Bleomycin Before External-Beam Radiotherapy Improves Locoregional Control in a Human Sarcoma Model

Purpose: The aim of this study was to explore the tumor growth response of the combination photochemical internalization and external-beam radiotherapy. Photochemical internalization is a technology to improve the utilization of therapeutic macromolecules in cancer therapy by photochemical release of endocytosed macromolecules into the cytosol. Methods and Materials: A human sarcoma xenograft TAX-1 was inoculated subcutaneously into nude mice. The photosensitizer AlPcS{sub 2a} and bleomycin were intraperitoneally administrated 48 h and 30 min, respectively, before diode laser light exposure at 670 nm (20 J/cm{sup 2}). Thirty minutes or 7 days after photochemical treatment, the animals were subjected to 4 Gy of ionizing radiation. Results: Using photochemical internalization of bleomycin as an adjunct to ionizing radiation increased the time to progression for the tumors from 17 to 33 days as compared with that observed with photodynamic therapy combined with ionizing radiation as well as for radiochemotherapy with bleomycin. The side effects observed when photochemical internalization of bleomycin was given shortly before ionizing radiation were eliminated by separating the treatment modalities in time. Conclusion: Photochemical internalization of bleomycin combined with ionizing radiation increased the time to progression and showed minimal toxicity and may therefore reduce the total radiation dose necessary to obtain local tumor control while avoiding long-term sequelae from radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Demonstration of efficient spin injection and detection in various systems using Fe{sub 3}O{sub 4} based spin injectors

Half-metal based spin injector devices for spin injection and detection application have proven to be efficient owing to their enhanced injection and detection efficiency. In this study, we extend the all-electrical spin injection and detection studies into different systems like Si and GaAs using half-metal Fe{sub 3}O{sub 4} as a spin injector in the presence and absence of tunnel barrier MgO. Injection into GaAs is verified using conventional Fe/MgO/GaAs devices. Room temperature spin injection into both p-type and n-type Si is achieved and the spin injection could be observed down to 100 K. Obtained spin relaxation time for these n-type and p-type Si at different temperatures agree well with the existing reports. Further, the temperature dependent spin injection and detection is also successfully achieved in Fe{sub 3}O{sub 4}/GaAs (n-type) Schottky devices, and a comparison study of the results with control experiment using Fe/MgO/GaAs (n-type) devices confirm the relaxation to be similar in the GaAs substrate, as expected. Hence, even Fe{sub 3}O{sub 4} material can be effectively used as an efficient spin injector as well as detector, making it an attractive candidate for the room temperature spintronics device applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

N+CPT clock resonance

In a typical compact atomic time standard a current modulated semiconductor laser is used to create the optical fields that interrogate the atomic hyperfine transition. A pair of optical sidebands created by modulating the diode laser become the coherent population trapping (CPT) fields. At the same time, other pairs of optical sidebands may contribute to other multiphoton resonances, such as three-photon N-resonance [Phys. Rev. A 65, 043817 (2002)]. We analyze the resulting joint CPT and N-resonance (hereafter N+CPT) analytically and numerically. Analytically we solve a four-level quantum optics model for this joint resonance and perturbatively include the leading ac Stark effects from the five largest optical fields in the laser's modulation comb. Numerically we use a truncated Floquet solving routine that first symbolically develops the optical Bloch equations to a prescribed order of perturbation theory before evaluating. This numerical approach has, as input, the complete physical details of the first two excited-state manifolds of {sup 87}Rb. We test these theoretical approaches with experiments by characterizing the optimal clock operating regimes.

74 ATOMIC AND MOLECULAR PHYSICS↗

Refine your search to explore more results.