Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “detector simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Observation of double electron-positron pair production by {gamma} rays reexamined

An experiment was conducted to observe triple- and quadruple-escape peaks, at a photon energy equal to 6.128 MeV, in the spectra recorded with a high-purity Ge detector working in coincidence with six bismuth germanate detectors. The peak intensities may be explained having recourse to only the bremsstrahlung cascade process of consecutive electron-positron pair creation; i.e., the contribution of simultaneous double pair formation (and other cascade effects) is much smaller. The experimental peak areas are in reasonably good agreement with those predicted by Monte Carlo simulations done with the general-purpose radiation-transport code PENELOPE.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Response of LiF:Mg,Ti thermoluminescent dosimeters at photon energies relevant to the dosimetry of brachytherapy (<1 MeV)

Purpose: High energy photon beams are used in calibrating dosimeters for use in brachytherapy since absorbed dose to water can be determined accurately and with traceability to primary standards in such beams, using calibrated ion chambers and standard dosimetry protocols. For use in brachytherapy, beam quality correction factors are needed, which include corrections for differences in mass energy absorption properties between water and detector as well as variations in detector response (intrinsic efficiency) with radiation quality, caused by variations in the density of ionization (linear energy transfer (LET) -distributions) along the secondary electron tracks. The aim of this work was to investigate experimentally the detector response of LiF:Mg,Ti thermoluminescent dosimeters (TLD) for photon energies below 1 MeV relative to {sup 60}Co and to address discrepancies between the results found in recent publications of detector response. Methods: LiF:Mg,Ti dosimeters of formulation MTS-N Poland were irradiated to known values of air kerma free-in-air in x-ray beams at tube voltages 25-250 kV, in {sup 137}Cs- and {sup 60}Co-beams at the Swedish Secondary Standards Dosimetry Laboratory. Conversions from air kerma free-in-air into values of mean absorbed dose in the dosimeters in the actual irradiation geometries were made using EGSnrc Monte Carlo simulations. X-ray energy spectra were measured or calculated for the actual beams. Detector response relative to that for {sup 60}Co was determined at each beam quality. Results: An increase in relative response was seen for all beam qualities ranging from 8% at tube voltage 25 kV (effective energy 13 keV) to 3%-4% at 250 kV (122 keV effective energy) and {sup 137}Cs with a minimum at 80 keV effective energy (tube voltage 180 kV). The variation with effective energy was similar to that reported by Davis et al.[Radiat. Prot. Dosim. 106, 33-43 (2003)] with our values being systematically lower by 2%-4%. Compared to the results by Nunn et al.[Med. Phys. 35, 1861-1869 (2008)], the relative detector response as a function of effective energy differed in both shape and magnitude. This could be explained by the higher maximum read-out temperature (350 deg. C) used by Nunn et al.[Med. Phys. 35, 1861-1869 (2008)], allowing light emitted from high-temperature peaks with a strong LET dependence to be registered. Use of TLD-100 by Davis et al.[Radiat. Prot. Dosim. 106, 33-43 (2003)] with a stronger super-linear dose response compared to MTS-N was identified as causing the lower relative detector response in this work. Conclusions: Both careful dosimetry and strict protocols for handling the TLDs are required to reach solid experimental data on relative detector response. This work confirms older findings that an over-response relative to {sup 60}Co exists for photon energies below 200-300 keV. Comparison with the results from the literature indicates that using similar protocols for annealing and read-out, dosimeters of different makes (TLD-100, MTS-N) differ in relative detector response. Though universality of the results has not been proven and further investigation is needed, it is anticipated that with the use of strict protocols for annealing and read-out, it will be possible to determine correction factors that can be used to reduce uncertainties in dose measurements around brachytherapy sources at photon energies where primary standards for absorbed dose to water are not available.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Machine learning and LHC event generation

First-principle simulations are at the heart of the high-energy physics research program. They link the vast data output of multi-purpose detectors with fundamental theory predictions and interpretation. This review illustrates a wide range of applications of modern machine learning to event generation and simulation-based inference, including conceptional developments driven by the specific requirements of particle physics. New ideas and tools developed at the interface of particle physics and machine learning will improve the speed and precision of forward simulations, handle the complexity of collision data, and enhance inference as an inverse simulation problem.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Using Quantum Sensors to Probe the Quasiparticle Excess in Quantum Circuits due to Ionizing Radiation

This project quantified natural ionizing radiation as a source of excess quasiparticles in superconducting quantum circuits. Thermal Kinetic Inductance Detectors (TKIDs) were developed and deployed to measure event‑by‑event energy deposition in silicon substrates at millikelvin temperatures. Measurements and radiation transport simulations showed strong agreement across keV–MeV energies, providing validated background models and design guidance to mitigate radiation‑induced decoherence in superconducting qubits and detectors.

97 MATHEMATICS AND COMPUTING↗

Recoil-proton track imaging as a new way for neutron spectrometry measurements

In this paper, recoil-proton track imaging (RPTI) is an attractive technique to optically record the tracks of recoil protons in scintillation gas by using realtime imaging devices. For the first time, its use as an online nuclear track detector for neutron spectrometry measurements (NSM) is explored. Based on the RPTI methodology for NSM, a very basic detector system is designed, consisting of the neutron-to-proton recoil system and proton track imaging system. Satisfactory performance of the RPTI neutron spectrometer has been examined with a series of Monte Carlo simulations. Moreover, using well-defined line-proton sources from a tandem accelerator, the capability of the detector for imaging proton tracks at the single-particle level in real time has been validated in preliminary experiments. From the clear single proton tracks in the images, the proton ranges were easily distinguished, and precise proton energy spectra were unfolded, laying a solid experimental foundation for the future implementation of NSM.

47 OTHER INSTRUMENTATION↗

High Momentum Transfer Nucleon Elastic Electromagnetic Form Factor Measurements Using Super BigBite Spectrometer at Jefferson Lab

The nucleons - protons and neutrons - are the basic building blocks of atomic nuclei. We now know that the nucleon consists of fundamental particles called quarks and gluons. The quarks interact with each other by exchanging gluons via the strong interaction. Understanding the quark-gluon structure of the nucleon, especially the confinement of quarks within the nucleon in its ground state, remains one of the main unsolved puzzles of particle physics. The nucleon electromagnetic form factors are directly related to the internal structure of the nucleon. A new generation of high precision experiments, GEp-V, GEn-II, GEn-RP, and GMn, measuring the ground state nucleon space-like electro-magnetic form factor at high momentum transfer is underway at Jefferson Lab experimental Hall-A as part of the Super Bigbite Spectrometer (SBS) program. This series of experiments will provide a new level of understanding of the nucleon structure. These experiments are highly demanding due to the extremely fast drop off of the elastic cross section with the increasing four-momentum transfer squared(Q2). This thesis provides an overview of the SBS physics program and reports on the extensive R&D program carried out to achieve the high rate running conditions essential for carrying out the SBS experiments. SBS will provide an intermediate solid angle of approximately 35 msr, which is significantly larger than the solid angle of other dipole based spectrometers at Jefferson lab. Of course, there are much larger acceptance spectrometers at Jefferson Lab, CLAS12 for example. What is special about SBS is that it provides a sizable acceptance while operating at the highest possible luminosity at Jefferson Lab. With this combination of medium acceptance and the highest available luminosity, SBS provides an unparalleled opportunity to explore the nucleon in its ground state with unprecedented resolution. The relatively large acceptance of SBS is achieved by using a large gap dipole magnet and placing it close to the target. An unavoidable consequence of this is that the SBS GEM trackers and other detectors have a clear line-of-sight view of the target and a portion of the beam-line. As a result, the background hit rate in the SBS front GEM trackers is expected to be up to 500 kHz/cm2, over the entire active area of 6000 cm2. To the best of our knowledge, this extremely high rate over such a large area is unprecedented in any particle tracking system used anywhere in the world before. Correctly reconstructing the particle tracks of interest in this very high background environment is achieved by using especially adapted high rate techniques at every step of the tracking process: optimizing the GEM module and tracker design at the hardware level, using high bandwidth electronics and real time Field Programmable Gate Array (FPGA) based background suppression techniques at the Data Acquisition (DAQ) level, and developing highly specialized tracking algorithms to pick out the signal hits from among the vast amount of background hits. In order to ensure a smooth start and running of the SBS experiments, it is extremely crucial that these techniques are developed, implemented, and tested under realistic conditions well before the actual start of the SBS experimental program. A detailed Geant4 simulation of the experiment was combined with a digitization package to generate the detector level pseudodata similar to what is expected in the actual experiments. The digitization procedures were calibrated against actual GEM data from cosmic-ray runs, X-ray tests, beam test runs in experimental Hall-A, and the PRad experiment in Hall B. Then, optimized tracking algorithms were developed and implemented in an analysis program used to analyze these pseudo-data and to extract expected high-level parameters. These extracted quantities were then compared with the input parameters from the simulation to verify and determine the performance characteristics for the SBS tracker. From this work, a final tracking efficiency of 69% at 25% occupancy was achieved, with the required reconstruction accuracy, for the GMn experiment, the first experiment in the SBS program, with background level at 100 kHz/cm2. These demonstrated parameters are adequate for the successful running of not only the GMn experiment but as well as for GEn-RP and GEn-II experiments, the second and third experiments in the program. This work builds the solid ground to further improve the tracking performance for these experiments and achieve similar conditions for the running of the GEp-V experiment, the most demanding experiment in the SBS program, with an expected background level at 500 kHz/cm2.

Di, Danning↗

Two-photon fluorescence microscopy signal formation in highly scattering media: theoretical and numerical simulation

Using the radiative transfer theory and Monte Carlo simulations, we analyse the effect of scattering in a medium and of the size of the detector pinhole on the formation of the fluorescent signal in standard two-photon fluorescence microscopy (TPFM) systems. The theoretical analysis is based on a small-angle diffusion approximation of the radiative transfer equation, adapted to calculate the propagation of focused infrared radiation in media similar to the biological tissues in their optical properties. The accuracy of the model is evaluated by comparing the calculated excitation intensity in a highly scattering medium with the results of Monte Carlo simulations. To simulate a tightly focused Gaussian beam by the Monte Carlo method, the so called 'ray-optics' approach that correctly takes into account the finite size and shape of the beam waist is applied. It is shown that in the combined confocal and two-photon scanning microscopy systems not equipped with an external 'nondescanned' detector, the scattering significantly affects both the nonlinear excitation efficiency in the medium and the fluorescence collection efficiency of the system. In such systems, the rate of the useful TPFM signal in-depth decay is 1.5 - 2 times higher than in systems equipped with a 'nondescanned' detector. (application of lasers and laser-optical methods in life sciences)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Radio frequency cavity analysis, measurement, and calibration of absolute Dee voltage for K-500 superconducting cyclotron at VECC, Kolkata

Variable Energy Cyclotron Centre has commissioned a K-500 superconducting cyclotron for various types of nuclear physics experiments. The 3-phase radio-frequency system of superconducting cyclotron has been developed in the frequency range 9-27 MHz with amplitude and phase stability of 100 ppm and {+-}0.2{sup 0}, respectively. The analysis of the RF cavity has been carried out using 3D Computer Simulation Technology (CST) Microwave Studio code and various RF parameters and accelerating voltages ('Dee' voltage) are calculated from simulation. During the RF system commissioning, measurement of different RF parameters has been done and absolute Dee voltage has been calibrated using a CdTe X-ray detector along with its accessories and known X-ray source. The present paper discusses about the measured data and the simulation result.

43 PARTICLE ACCELERATORS↗

Beam Dynamics Challenges in the Muon g-2 Experiment

The muon&s;s anomalous magnetic moment $a_{\mu}$ has hinted at physics beyond the standard model for nearly 20 years. The Muon $g-2$ experiment at Fermilab aims to measure $a_{\mu}$ to 140 parts per billion (ppb) precision. The 460 ppb result from its first data run (Run-1), released in 2021, agreed with the previous 2006 Brookhaven Muon $g-2$ result. The experimental average stands in tension with the standard model theory $a_{\mu}$ prediction by $4.2 \sigma$. The result of Run-2/3 data analysis is set be released in summer 2023, and will improve on the Run-1 precision by a factor of two. With the data collected in all six runs, the experiment is on track to produce a 140 ppb measurement of $a_{\mu}$. If the experiment and theory central values are both unchanged, the tension would exceed $5 \sigma$. The measurement is accomplished by injecting muons into a magnetic storage ring and precisely measuring two observable frequencies: $\omega_a$, the muons&s; anomalous precession frequency, and $\tilde{\omega}&s;_p$, the precession frequency of protons which determines the magnetic field strength experienced by the muons. This thesis presents a selection of muon beam dynamics effects which are critical for reaching the experiment precision goal. A system of detectors assists with the challenging beam injection into the storage ring, and a measurement of the injected beam provides input for simulating the stored beam dynamics. A new method is introduced to reduce a critical systemic caused by time dependence in the stored beam momentum, enabled by a detector which directly profiles the stored beam. Finally the analysis of $\tilde{\omega}&s;_p$, the muon-weighted magnetic field, for the Run-2/3 result is presented. Systematics of $\tilde{\omega}&s;_p$ due to beam effects are evaluated in detail, and shown to be sub-dominant.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neutron angular distribution in plutonium-240 spontaneous fission

Nuclear safeguards applications require accurate fission models that exhibit prompt neutron anisotropy. We observed an anisotropic neutron angular distribution, in the laboratory reference frame, because prompt fission neutrons carry momentum from fully accelerated fission fragments. Furthermore, a liquid organic scintillation detector array was used with pulse shape discrimination techniques to produce neutron-neutron cross-correlation time distributions and angular distributions from spontaneous fission in a 252 Cf, a 0.84 g 240 Pu eff metal, and a 1.63 g 240 Pu eff metal sample. The effect of cross-talk, estimated with MCNPX-PoliMi simulations, is removed from neutron-neutron coincidences as a function of the angle between detector pairs. Fewer coincidences were observed at detector angles near 90°, relative to higher and lower detector angles. As light output threshold increases, the observed anisotropy increases due to spectral effects arising from fission fragment momentum transfer to emitted neutrons. Stronger anisotropy was observed in Cf-252 spontaneous fission prompt neutrons than in Pu-240 neutrons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Resolving the mass hierarchy with atmospheric neutrinos using a liquid argon detector

We explore the potential offered by large-mass liquid argon detectors for determination of the sign of {delta}m{sub 31}{sup 2}, or the neutrino mass hierarchy, through interactions of atmospheric neutrinos. We give results for a 100 kT sized magnetized detector which provides separate sensitivity to {nu}{sub {mu}}, {nu}{sub {mu}} and, over a limited energy range, to {nu}{sub e}, {nu}{sub e}. We also discuss the sensitivity for the unmagnetized version of such a detector. After including the effect of smearing in neutrino energy and direction and incorporating the relevant statistical, theoretical, and systematic errors, we perform a binned {chi}{sup 2} analysis of simulated data. The {chi}{sup 2} is marginalized over the presently allowed ranges of neutrino parameters and determined as a function of {theta}{sub 13}. We find that such a detector offers superior capabilities for hierarchy resolution, allowing a >4{sigma} determination for a 100 kT detector over a 10-year running period for values of sin{sup 2}2{theta}{sub 13}{>=}0.05. For an unmagnetized detector, a 2.5{sigma} hierarchy sensitivity is possible for sin{sup 2}2{theta}{sub 13}=0.04.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Combined SM Higgs Limits at the Tevatron

We combine results from CDF and D{sup 0} on direct searches for a standard model (SM) Higgs boson (H) in p{bar p} collisions at the Fermilab Tevatron at {radical}s = 1.96 TeV. Compared to the previous Higgs Tevatron combination, more data and new channels WH {yields} {tau}{nu}b{bar b}, VH {yields} {tau}{tau}b{bar b}/jj{tau}{tau}, VH {yields} jjb{bar b}, t{bar t}H {yields} t{bar t}b{bar b} have been added. Most previously used channels have been reanalyzed to gain sensitivity. We use the latest parton distribution functions and gg {yields} H theoretical cross sections when comparing our limits to the SM predictions. With 2.0-3.6 fb{sup -1} of data analyzed at CDF, and 0.9-4.2 fb{sup -1} at D{sup 0}, the 95% C.L. upper limits on Higgs boson production are a factor of 2.5 (0.86) times the SM cross section for a Higgs boson mass of m{sub H} = 115 (165) GeV/c{sup 2}. Based on simulation, the corresponding median expected upper limits are 2.4 (1.1). The mass range excluded at 95% C.L. for a SM Higgs has been extended to 160 < m{sub H} < 170 GeV/c{sup 2}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measuring neutron star radius with second and third generation gravitational wave detector networks

The next generation of ground-based interferometric gravitational wave detectors will observe mergers of black holes and neutron stars throughout cosmic time. A large number of the binary neutron star merger events will be observed with extreme high fidelity, and will provide stringent constraints on the equation of state of nuclear matter. In this paper, we investigate the systematic improvement in the measurability of the equation of state with increase in detector sensitivity by combining constraints obtained on the radius of a 1.4 M ⊙ neutron star from a simulated source population. Since the measurability of the equation of state depends on its stiffness, we consider a range of realistic equations of state that span the current observational constraints. We show that a single 40 km Cosmic Explorer detector can pin down the neutron star radius for a soft, medium and stiff equation of state with a precision of 10 m within a decade, whereas the current generation of ground-based detectors like the Advanced LIGO-Virgo network would take $\mathcal{O}(10_5)$ years to do so for a soft equation of state.

79 ASTRONOMY AND ASTROPHYSICS↗

A high efficiency veto to increase the sensitivity of ZEPLIN-III, a WIMP detector

An active veto detector to complement the ZEPLIN-III two phase Xenon, direct dark matter device is described. The proposed design consists of 52 plastic scintillator segments, individually read out by high efficiency photomultipliers, coupled to a Gd loaded passive polypropylene shield. Experimental work was performed to determine the plastic scintillator characteristics which were used to inform a complete end-to-end Monte Carlo simulation of the expected performance of the new instrument, both operating alone and as an active veto detector for ZEPLIN-III. The veto device will be capable of tagging over 65% of coincident nuclear recoil events in the energy range of interest in ZEPLIN-III, and over 12% for gamma ray rejection, while contributing no significant additional background. In addition it will also provide valuable diagnostic capabilities. The inclusion of the veto to ZEPLIN-III will aid to significantly improve the sensitivity to spin independent WIMP-nucleon cross sections below 10{sup -8} pb.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Digital pile-up rejection for plutonium experiments with solution-grown stilbene

A solution-grown stilbene detector was used in several experiments with plutonium samples including plutonium oxide, mixed oxide, and plutonium metal samples. Neutrons from different reactions and plutonium isotopes are accompanied by numerous gamma rays especially by the 59-keV gamma ray of 241Am. Identifying neutrons correctly is important for nuclear nonproliferation applications and makes neutron/gamma discrimination and pile-up rejection necessary. Each experimental dataset is presented with and without pile-up filtering using a previously developed algorithm. The experiments were simulated using MCNPX-PoliMi, a Monte Carlo code designed to accurately model scintillation detector response. Collision output from MCNPX-PoliMi was processed using the specialized MPPost post-processing code to convert neutron energy depositions event-by-event into light pulses. The model was compared to experimental data after pulse-shape discrimination identified waveforms as gamma ray or neutron interactions. We show that the use of the digital pile-up rejection algorithm allows for accurate neutron counting with stilbene to within 2% even when not using lead shielding

Bourne, M. M.↗

Impact of Changes in ENDF/B-VII.1 and ENDF/B-VIII.0 235U Nuclear Data Indicated by NDSE Studies on LLNL Pulsed Sphere Simulations

A recent journal article by J.A. Gomez et al. measured gamma-ray die-off curves of three subcritical static highly-enriched uranium (HEU) assemblies driven by an external neutron source with a new detector system. This new detector system was developed for being used in dynamically driven subcritical assemblies as part of the Neutron Diagnosed Subcritical Experiments (NDSE) program. Simulations of these die-off curves with various nuclear data and comparison to experimental data indicated that a decrease of the ENDF/B-VII.1 235 U(n,inl) cross section by a factor 0.8 and 0.85 for ENDF/B-VIII.0 would lead to better predictions of experimental data. Here, we test the proposed changes with another type of measurement response, namely neutron-leakage spectra emitted in LLNL pulsed sphere measurements. These spheres were pulsed by 14-MeV neutrons produced via the D+T reaction in their center. The proposed changes in nuclear data have a distinctly smaller impact on predicting pulsed-sphere neutron-leakage spectra than for the die-off curves; they lead to a worsened prediction of the inelastic valley of LLNL pulsed-sphere neutron spectra indicating that the proposed change could constitute a compensating error. Changes in the inelastic angular distributions along with the cross section might be worthwhile to study

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Realistic training scenario simulations and simulation techniques

In one embodiment, a system includes a signal generator operatively coupleable to one or more detectors; and a controller, the controller being both operably coupled to the signal generator and configured to cause the signal generator to: generate one or more signals each signal being representative of at least one emergency event; and communicate one or more of the generated signal(s) to a detector to which the signal generator is operably coupled. In another embodiment, a method includes: receiving data corresponding to one or more emergency events; generating at least one signal based on the data; and communicating the generated signal(s) to a detector.

99 GENERAL AND MISCELLANEOUS↗

Refine your search to explore more results.