Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “correspondence”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Dosimetric evaluation of a three-phase adaptive radiotherapy for nasopharyngeal carcinoma using helical tomotherapy

Adaptive radiotherapy (ART) has been introduced to correct the radiation-induced anatomic changes in head and neck cases during a treatment course. This study evaluated the potential dosimetric benefits of applying a 3-phase adaptive radiotherapy protocol in nasopharyngeal carcinoma (NPC) patients compared with the nonadaptive single-phase treatment protocol. Ten NPC patients previously treated with this 3-phase radiation protocol using Hi-Art Tomotherapy were recruited. Two new plans, PII-ART and PIII-ART, were generated based on the up-to-date computed tomography (CT) images and contours and were used for treatment in phase two (PII; after 25th fraction) and phase three (PIII; after 35th fraction), respectively. To simulate the situation of no replanning, 2 hybrid plans denoted as PII-NART and PIII-NART were generated using the original contours pasted on the PII- and PIII-CT sets by CT-CT fusion. Dosimetric comparisons were made between the NART plans and the corresponding ART plans. In both PII- and PIII-NART plans, the doses to 95% of all the target volumes (D{sub 95}) were increased with better dose uniformity, whereas the organs at risk (OARs) received higher doses compared with the corresponding ART plans. Without replanning, the total dose to 1% of brainstem and spinal cord (D{sub 1}) significantly increased 7.87 {+-} 7.26% and 10.69 {+-} 6.72%, respectively (P = 0.011 and 0.001, respectively), in which 3 patients would have these structures overdosed when compared with those with two replannings. The total maximum doses to the optic chiasm and pituitary gland and the mean doses to the left and right parotid glands were increased by 10.50 {+-} 10.51%, 8.59 {+-} 6.10%, 3.03 {+-} 4.48%, and 2.24 {+-} 3.11%, respectively (P = 0.014, 0.003, 0.053, and 0.046, respectively). The 3-phase radiotherapy protocol showed improved dosimetric results to the critical structures while keeping satisfactory target dose coverage, which demonstrated the advantages of ART in helical tomotherapy of NPC.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetric influences of rotational setup errors on head and neck carcinoma intensity-modulated radiation therapy treatments

The purpose of this work is to investigate the dosimetric influence of the residual rotational setup errors on head and neck carcinoma (HNC) intensity-modulated radiation therapy (IMRT) with routine 3 translational setup corrections and the adequacy of this routine correction. A total of 66 kV cone beam computed tomography (CBCT) image sets were acquired on the first day of treatment and weekly thereafter for 10 patients with HNC and were registered with the corresponding planning CT images, using 2 3-dimensional (3D) rigid registration methods. Method 1 determines the translational setup errors only, and method 2 determines 6-degree (6D) setup errors, i.e., both rotational and translational setup errors. The 6D setup errors determined by method 2 were simulated in the treatment planning system and were then corrected using the corresponding translational data determined by method 1. For each patient, dose distributions for 6 to 7 fractions with various setup uncertainties were generated, and a plan sum was created to determine the total dose distribution through an entire course and was compared with the original treatment plan. The average rotational setup errors were 0.7°± 1.0°, 0.1°±1.9°, and 0.3°±0.7° around left-right (LR), anterior-posterior (AP), and superior-inferior (SI) axes, respectively. With translational corrections determined by method 1 alone, the dose deviation could be large from fraction to fraction. For a certain fraction, the decrease in prescription dose coverage (V{sub p}) and the dose that covers 95% of target volume (D{sub 95}) could be up to 15.8% and 13.2% for planning target volume (PTV), and the decrease in V{sub p} and the dose that covers 98% of target volume (D{sub 98}) could be up to 9.8% and 5.5% for the clinical target volume (CTV). However, for the entire treatment course, for PTV, the plan sum showed that the average V{sub p} was decreased by 4.2% and D{sub 95} was decreased by 1.2 Gy for the first phase of IMRT with a prescription dose of 50 Gy. For CTV, the plan sum showed that the average V{sub p} was decreased by 0.8% and D{sub 98}, relative to prescription dose, was not decreased. Among these 10 patients, the plan sum showed that the dose to 1-cm{sup 3} spinal cord (D{sub 1cm{sup 3}}) increased no more than 1 Gy for 7 patients and more than 2 Gy for 2 patients. The average increase in D{sub 1cm{sup 3}} was 1.2 Gy. The study shows that, with translational setup error correction, the overall CTV V{sub p} has a minor decrease with a 5-mm margin from CTV to PTV. For the spinal cord, a noticeable dose increase was observed for some patients. So to decide whether the routine clinical translational setup error correction is adequate for this HNC IMRT technique, the dosimetric influence of rotational setup errors should be evaluated carefully from case to case when organs at risk are in close proximity to the target.

61 RADIATION PROTECTION AND DOSIMETRY↗

Radiobiologic comparison of helical tomotherapy, intensity modulated radiotherapy, and conformal radiotherapy in treating lung cancer accounting for secondary malignancy risks

The aim of the present study is to examine the importance of using measures to predict the risk of inducing secondary malignancies in association with the clinical effectiveness of treatment plans in terms of tumor control and normal tissue complication probabilities. This is achieved by using radiobiologic parameters and measures, which may provide a closer association between clinical outcome and treatment delivery. Overall, 4 patients having been treated for lung cancer were examined. For each of them, 3 treatment plans were developed based on the helical tomotherapy (HT), multileaf collimator-based intensity modulated radiation therapy (IMRT), and 3-dimensional conformal radiation therapy (CRT) modalities. The different plans were evaluated using the complication-free tumor control probability (p{sub +}), the overall probability of injury (p{sub I}), the overall probability of control/benefit (p{sub B}), and the biologically effective uniform dose (D{sup ¯¯}). These radiobiologic measures were used to develop dose-response curves (p-D{sup ¯¯} diagram), which can help to evaluate different treatment plans when used in conjunction with standard dosimetric criteria. The risks for secondary malignancies in the heart and the contralateral lung were calculated for the 3 radiation modalities based on the corresponding dose-volume histograms (DVHs) of each patient. Regarding the overall evaluation of the different radiation modalities based on the p{sub +} index, the average values of the HT, IMRT, and CRT are 67.3%, 61.2%, and 68.2%, respectively. The corresponding average values of p{sub B} are 75.6%, 70.5%, and 71.0%, respectively, whereas the average values of p{sub I} are 8.3%, 9.3%, and 2.8%, respectively. Among the organs at risk (OARs), lungs show the highest probabilities for complications, which are 7.1%, 8.0%, and 1.3% for the HT, IMRT, and CRT modalities, respectively. Similarly, the biologically effective prescription doses (D{sub B}{sup ¯¯}) for the HT, IMRT, and CRT modalities are 64.0, 60.9, and 60.8 Gy, respectively. Regarding the risk for secondary cancer, for the heart, the lowest average risk is produced by IMRT (0.10%) compared with the HT (0.17%) and CRT (0.12%) modalities, whereas the 3 radiation modalities show almost equivalent results regarding the contralateral lung (0.8% for HT, 0.9% for IMRT, and 0.9% for CRT). The use of radiobiologic parameters in the evaluation of different treatment plans and estimation of their expected clinical outcome is shown to provide very useful clinical information. The radiobiologic analysis of the response probabilities showed that different radiation modalities appear to be more effective in different patient geometries and target sizes and locations. Furthermore, there is not a clear pattern between the plans that appear to be more effective for the treatment and the risk of secondary malignancy. It seems that radiobiologically based treatment planning taking into account the risk of secondary cancer can be established as an effective clinical tool for a more clinically relevant treatment optimization.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetric comparison of two arc-based stereotactic body radiotherapy techniques for early-stage lung cancer

To compare the dosimetric and delivery characteristics of two arc-based stereotactic body radiotherapy (SBRT) techniques for early-stage lung cancer treatment. SBRT treatment plans for lung tumors of different sizes and locations were designed using a single-isocenter multisegment dynamic conformal arc technique (SiMs-arc) and a volumetric modulated arc therapy technique (RapidArc) for 5 representative patients treated previously with lung SBRT. The SiMs-arc plans were generated with the isocenter located in the geometric center of patient's axial plane (which allows for collision-free gantry rotation around the patient) and 6 contiguous 60° arc segments spanning from 1° to 359°. 2 RapidArc plans, one using the same arc geometry as the SiMs-arc and the other using typical partial arcs (210°) with the isocenter inside planning target volume (PTV), were generated for each corresponding SiMs-arc plan. All plans were generated using the Varian Eclipse treatment planning system (V10.0) and were normalized with PTV V{sub 100} to 95%. PTV coverage, dose to organs at risk, and total monitor units (MUs) were then compared and analyzed. For PTV coverage, the RapidArc plans generally produced higher PTV D{sub 99} (by 1.0% to 3.3%) and higher minimum dose (by 2.7% to 12.7%), better PTV conformality index (by 1% to 8%), and less volume of 50% dose outside 2 cm from PTV (by 0 to 20.8 cm{sup 3}) than the corresponding SiMs-arc plans. For normal tissues, no significant dose differences were observed for the lungs, trachea, chest wall, and heart; RapidArc using partial arcs produced lowest maximum dose to spinal cord. For dose delivery, the RapidArc plans typically required 50% to 90% more MUs than SiMs-arc plans to deliver the same prescribed dose. The additional intensity modulation afforded by variable gantry speed and dose rate and by overlapping arcs enabled RapidArc plans to produce dosimetrically improved plans for lung SBRT, but required more MUs (by a factor > 1.5) to deliver. The dosimetric improvements, most notably in PTV minimum dose and in dose conformality for irregularly shaped PTVs, may outweigh the increased MUs in using RapidArc. For small and peripherally located tumors, SiMs-arc produces comparable dosimetric quality and could be more efficient in both treatment planning and dose delivery.

61 RADIATION PROTECTION AND DOSIMETRY↗

Method of predicting the mean lung dose based on a patient's anatomy and dose-volume histograms

The aim of this study was to propose a method to predict the minimum achievable mean lung dose (MLD) and corresponding dosimetric parameters for organs-at-risk (OAR) based on individual patient anatomy. For each patient, the dose for 36 equidistant individual multileaf collimator shaped fields in the treatment planning system (TPS) was calculated. Based on these dose matrices, the MLD for each patient was predicted by the homemade DosePredictor software in which the solution of linear equations was implemented. The software prediction results were validated based on 3D conformal radiotherapy (3D-CRT) and volumetric modulated arc therapy (VMAT) plans previously prepared for 16 patients with stage III non–small-cell lung cancer (NSCLC). For each patient, dosimetric parameters derived from plans and the results calculated by DosePredictor were compared. The MLD, the maximum dose to the spinal cord (D{sub max} {sub cord}) and the mean esophageal dose (MED) were analyzed. There was a strong correlation between the MLD calculated by the DosePredictor and those obtained in treatment plans regardless of the technique used. The correlation coefficient was 0.96 for both 3D-CRT and VMAT techniques. In a similar manner, MED correlations of 0.98 and 0.96 were obtained for 3D-CRT and VMAT plans, respectively. The maximum dose to the spinal cord was not predicted very well. The correlation coefficient was 0.30 and 0.61 for 3D-CRT and VMAT, respectively. The presented method allows us to predict the minimum MLD and corresponding dosimetric parameters to OARs without the necessity of plan preparation. The method can serve as a guide during the treatment planning process, for example, as initial constraints in VMAT optimization. It allows the probability of lung pneumonitis to be predicted.

61 RADIATION PROTECTION AND DOSIMETRY↗

Comparison between DVH-based doses and ICRU point-based doses to the rectum and the bladder using CT-based high-dose rate brachytherapy to the cervix

Traditionally, doses to the bladder and the rectum were quantified using the bladder and rectal reference points defined by the International Commission on Radiation Units and Measurements (ICRU) in Report No. 38. In this study, we compared the 0.1-, 1.0-, 2.0-cc doses to the bladder and the rectum with the corresponding ICRU point doses using computed tomography (CT)-based planning in the intracavitary brachytherapy of carcinoma of the cervix. CT datasets of 136 consecutive intracavitary brachytherapy insertions between January and May 2015 were analyzed. The bladder and the rectum were contoured on consecutive CT slices as per Groupe Europeen de Curietherapie and the European Socie Ty for Radiotherapy and Oncology recommendations. Dose volume histograms were generated and doses of 0.1, 1.0, and 2.0 cc to the bladder and the rectum were recorded. ICRU bladder and rectal points were identified in the treatment plan. Mean doses of 0.1, 1.0, and 2.0 cc to the bladder was found to be 2.02, 1.57, and 1.35 times the ICRU point dose, respectively. The maximum dose received by the bladder was found to be 5.83 times the average ICRU point dose. Mean doses of 0.1, 1.0, and 2.0 cc to the rectum were found to be 1.12, 0.90, and 0.78 times the ICRU rectal point dose, respectively. The maximum dose received by the rectum was 4.79 times the average ICRU point dose. The Pearson correlation coefficient value (r) was found to be 0.639 for D2cc and ICRU bladder point values. The Pearson correlation coefficient value was found to be 0.752 for D2cc and ICRU rectal point values. Our results show that the ICRU bladder points underestimated the dose to the bladder, which is in agreement with other studies. ICRU rectal point doses were higher than the corresponding D2cc doses. However, there was a good correlation between D2cc and ICRU point doses for both the bladder and the rectum.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optical spectroscopy of molten fluorides: Methods, electronic and vibrational data, structural interpretation, and relevance to radiative heat transfer

In this study, to help address the need for predicting radiative heat transfer (RHT) behavior of molten salts, we conducted a comprehensive review of methods and data from optical spectroscopic measurements on molten fluoride salts. Transmittance, reflectance, and trans-reflectance experimental methods are discussed, along with the corresponding data reduction methodology and the limitations of each technique. Optical spectroscopy is a convenient indirect probe for changes in structural parameters with temperature and composition. Electronic and vibrational absorption data for transition-metal, lanthanide, and actinide solutes and vibrational absorption data for alkali and alkaline earth fluoride solvents are compiled, and the corresponding structural interpretation is discussed and compared with other experimental and theoretical work. We find that solvent and solute vibrational absorption can be significant in the mid-infrared, resulting in near-infrared edges of significance to RHT. Extrapolation and averaging of existing edge data leads to estimated gray absorption coefficient values at 700 °C of 546 m —1 for FLiBe and 276 m —1 for FLiNaK, both within the range of 1 – 6000 m —1 identified to be of engineering relevance for radiative heat transfer analysis.

36 MATERIALS SCIENCE↗

Interaction of the cesium cation with calix[4]arene-bis(t-octylbenzo-18-crown-6): Extraction and DFT study

From extraction experiments and c-activity measurements, the extraction constant corresponding to the equilibrium Cs+ (aq) + I (aq) + 1 (org),1Cs+ (org) + I (org) taking place in the two-phase water-phenyltrifluoromethyl sulfone (abbrev. FS 13) system (1 = calix[4]arene-bis(t-octylbenzo-18-crown-6); aq = aqueous phase, org = FS 13 phase) was evaluated as logKex (1Cs+, I) = 2.1 0.1. Further, the stability constant of the 1Cs+ complex in FS 13 saturated with water was calculated for a temperature of 25 C: log borg (1Cs+) = 9.9 0.1. Finally, by using quantum mechanical DFT calculations, the most probable structure of the cationic complex species 1Cs+ was derived. In the resulting 1Cs+ complex, the central cation Cs+ is bound by eight bond interactions to six oxygen atoms of the respective 18-crown-6 moiety and to two carbons of the corresponding two benzene rings of the parent ligand 1 via cation p interaction.

cesium cation↗

A chiral alkali metal capped Ni 4 cubane complex: Synthesis, structure, magnetic and catalytic bromination studies

A new chiral NaO 2 Ni 4 O 2 N 2 cluster has been developed with a distorted capped cubane-type structure. The structure was determined by single crystal X-ray diffraction. The tetradentate Schiff-base ligand was synthesized by the condensation of o-vanillin and $\textit{D}$-(-)–threo-2-amino-1-(4-nitrophenyl)-1,3-propanediol. X-ray structure reveals that the complex possesses a Ni 4 cubane cluster where sodium ion is anchored on the face of the cubane structure. Continuous shape measurement studies revealed that all the Ni centres are in distorted octahedral geometry and sodium ion adopts the spherical square pyramidal geometry. Further structural exploration reveals that the complex shows local distortions of the coordination geometries at each metal site, and these distortions govern the magnetic anisotropy associated with each Ni II ion. For the present case, an elongation ($d_{str}$ > 0) of the octahedral coordination sphere results in a local easy-plane anisotropy, with a positive $D_{Ni(II)}$ parameter. Temperature dependant magnetization measurements showed a predominant ferromagnetic interaction amongst the four Ni centres. This complex is also catalytically active towards bromination of aromatic phenolic compounds. Initial catalytic activity was verified with the conversion of phenol red to bromophenol blue. Different phenolic substances show good conversion to their corresponding bromo derivatives. The complex showed good catalytic activity towards bromination of aromatic phenolic compounds, offering up to 99% conversion with 100% selectively to their corresponding bromo derivatives.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of aging temperature on phase decomposition and mechanical properties in cast duplex stainless steels

The microstructure and mechanical properties in unaged and thermally aged (at 280 oC, 320 oC, 360 oC, and 400 oC to 4300 h) CF–3 and CF–8 cast duplex stainless steels (CDSS) are investigated. The unaged CF–8 steel has Cr-rich M23C6 carbides located at the δ–ferrite/γ– austenite heterophase interfaces that were not observed in the CF–3 steel and this corresponds to a difference in mechanical properties. Both unaged steels exhibit incipient spinodal decomposition into Fe-rich α–domains and Cr-rich α’–domains. During aging, spinodal decomposition progresses and the mean wavelength (MW) and mean amplitude (MA) of the compositional fluctuations increase as a function of aging temperature. Additionally, G–phase precipitates form between the spinodal decomposition domains in CF–3 at 360 oC and 400 oC and in CF–8 at 400 oC. The microstructural evolution is correlated to changes in mechanical properties.

atom probe tomography↗

The in-depth residual strain heterogeneities due to an indentation and a laser shock peening for Ti-6Al-4V titanium alloy

In this paper, heterogeneity of the through-thickness residual strain due to the laser shock peening (LSP) in comparison with that due to the indentation was studied in Ti-6Al-4V alloy samples. The latter is almost a quasi-static process while the former features extremely high strain-rate deformation. The synchrotron based high-energy X-ray diffraction was employed to investigate the through-thickness residual strain distribution. The studied two samples after the two processing procedures share the following features: (i) the pressure affected depths are both ~2 mm and (ii) the largest magnitudes of the compressive residual strains parallel to the surface are ~4,000 με. However, the pit depth for the indentation sample is ~9 times larger than that for the LSP. The position featuring the largest magnitude of the compressive residual strain is in the sub-surface for the indentation while it is in the surface for the LSP. Results of the elastic-visco-plastic finite element simulation for the indentation indicate that the position featuring the maximum accumulative plastic shear as defined in this paper corresponds to the location with the largest magnitude of compressive residual strain. To validate this finding, full width at half maximum (FWHM) of the X-ray diffraction profile, which is proportional to the level of the plastic deformation, is also studied. Finally, it is found that positions with the largest FWHM indeed correspond to the largest magnitude of compressive residual strain for both tests.

36 MATERIALS SCIENCE↗

Characterization of precipitation in gradient Inconel 718 superalloy

Inconel 718 (IN718) superalloy is a well-established material for the application of aircraft engine and power generator due to its excellent performance at high temperatures. The outstanding mechanical properties of IN718 are largely determined by the precipitates. Here, we investigated the precipitation behaviors and the corresponding mechanical properties of the heat-treated gradient IN718 alloy. The microscopy studies reveal that high-density hexagonal η phase with chemistry of Ni 3 (Al,Ti,Nb) formed in the nanograined IN718 alloy after annealing at 700 °C. Additionally, the compressive stress introduced during severe plastic deformation may have prohibited the formation of γ” phase while accelerated the precipitation of γ’ phase, consequently favoring the precipitation of η phase. The corresponding evolution of mechanical behavior of gradient IN718 alloy is investigated.

36 MATERIALS SCIENCE↗

Concentric core-shell tracks and spectroscopic properties of SrTiO 3 under intense electronic excitation

A deeper understanding of the intrinsic link between the irradiation-induced microstructures and the corresponding spectroscopic properties is becoming increasingly attractive for the research fields of materials science, physics, and information technology. In this work, the structural damage response, spectroscopic features, and associated physical mechanisms of SrTiO 3 single crystals under swift heavy ion irradiation were comparatively analyzed using a combination of experimental and theoretical approaches. Corresponding to 0.11–5.00 MeV/u ion irradiation with electronic energy loss ranging from 4.0 to 29.3 keV/nm, the inelastic thermal spike calculations combined with molecular dynamics simulations are compared with the experimental observations, revealing the track fine structures (individual spherical defects with a disordered region, and discontinuous and continuous tracks consisting of an amorphous core and a disordered outer shell) and demonstrating the dominant effects of the deposition energy and lattice temperature on track damage formation and evolution; thus, two essential thresholds for defect formation of ~0.60 eV/atom and amorphous region formation of ~1.81 eV/atom were identified to better describe the concentric core-shell track structure. The enhanced nanohillock formation in the surface region is attributed to the combined action of kinetic and potential energy depositions, and the fluence dependence in regulating the hillock dimensions is also presented. The measured refractive index profiles along different crystal axes further indicate the anisotropy of irradiation-induced lattice expansion. With increasing ion fluence and damage level, the intrinsic bandgap gradually decreased, and the concentration of additional radiative recombination centers (1.81 eV, 2.31 eV, and 2.42 eV) accordingly increased in the SrTiO 3 crystal, providing the possibility of regulating related defects to achieve tunable/selective photon emission for more critical technological applications.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Preliminary Evaluation and Uncertainty Quantification of the Prompt Fission Neutron Spectrum of {sup 239}Pu

Low evaluated uncertainties were obtained in a previous evaluation of the {sup 239}Pu prompt fission neutron spectrum and associated covariances for incident neutrons of 0.5 MeV, which were enlarged a-posteriori before being incorporated into ENDF/B-VII.1. These low evaluated uncertainties triggered an in-depth study and improved estimate of experimental as well as model uncertainties. Here, we will summarize these efforts and show that the improved estimate of experimental and model uncertainties leads to corresponding evaluated uncertainties in good agreement with uncertainties obtained in a statistical analysis based primarily on experimental information.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nuclear Data Sheets for A = 70

Spectroscopic data for all nuclei with mass number A = 70 have been evaluated, and the corresponding level schemes from radioactive decay and reaction studies are presented. Since the previous evaluation, the half-life of {sup 70}Mn has been measured and excited states in {sup 70}Fe observed for the first time. Excited states in {sup 70}Ni have been more extensively studied while Coulomb excitation and collinear laser spectroscopy measurements in {sup 70}Cu have allowed for firm Jπ assignments. Despite new measurements, there remain some discrepancies in half-lives of low lying states in {sup 70}Zn. New measurements have extended the knowledge of high-spin band structures in {sup 70}Ge and {sup 70}As. This evaluation supersedes the prior A = 70 evaluation of 2004Tu09.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Recommended Nuclear Data for the Production of Selected Therapeutic Radionuclides

Increasing interest in the treatment of human disease by means of targeted radionuclide-based therapies requires an accurate understanding of achievable yields and quantification of realisable degrees of purity. Important studies within a more extensive Coordinated Research Project of the International Atomic Energy Agency (IAEA CRP) have included in-depth assessments and evaluations of all available measured cross-section data for ten nuclear reactions leading to the formation of 131 Cs, 131 Ba, 225 Ac, 225 Ra, 227 Th, 227 Ac, 230 U and 230 Pa for various on-going and proposed therapeutic applications in nuclear medicine. Equivalent studies were also undertaken of possible reactions to produce the 178W /low-spin 178m Ta generator system that has been clinically applied in diagnosis by means of SPECT - these particular cross-section studies and recommendations are included in this paper for completeness. All available measured data have been critically reviewed and assessed to produce statistically consistent datasets. Selected datasets have been fitted by a least-squares method with Padé approximations of variable order to evaluate the production cross sections and corresponding uncertainties. New measurements have been made in some instances, and reported data have been adjusted to accommodate new nuclear decay or monitor reaction data which altered the original reported quantities adversely. Insufficient measured data are available in many cases to permit a reliable evaluation of cross sections, and these instances are discussed. Finally, recommended therapeutic radionuclide production reaction data and their uncertainties are available on the Web page of the IAEA Nuclear Data Section at www-nds.iaea.org/radionuclides/ and also at the IAEA medical portal www-nds.iaea.org/medportal/.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Design considerations for a higher-order-mode dielectric-loaded power extractor set for millimeter-wave generation.

The design of an electron-beam excited device for millimeter-wave generation is presented. Referred to as a dielectric-loaded power extractor, it is based on the higher-order-mode operation of a dielectric-loaded waveguide. With a matching transition, the unit can deliver power to the output waveguide at one of two frequencies, 20.8 and 35.1 GHz, corresponding to the TM{sub 02} and TM{sub 03} modes, respectively. By properly choosing the thickness of the dielectric lining, both modes are tuned to synchronize with an ultra-relativistic electron beam traversing the unit so that the wakefield generated by the beam is excited at these modes, chosen to be at 20.8 and 35.1 GHz, respectively, both corresponding to a harmonic of the 1.3 GHz operating frequency at an accelerator facility. Power generated in the unintended TM{sub 01} mode is effectively suppressed for bunch train operation by a novel technique. The device consists of a dielectric-loaded decelerating structure and two changeable output couplers to deliver the millimeter-wave power to a standard waveguide. For a drive beam with 50 nC of charge per bunch, power levels of 90.4 and 8.68 MW are expected to be delivered by the device at 20.8 and 35.1 GHz, respectively.

36 MATERIALS SCIENCE↗

Yield, variance and spatial distribution of electron–hole pairs in CsI

A Monte Carlo (MC) method previously developed has been applied to simulate the interaction of photons, with energies ranging from 50 eV to ~ 1 MeV, with CsI and the subsequent electron cascades. The MC model has been employed to compute nano-scale spatial distributions of electron-hole pairs and important intrinsic properties, including W, the mean energy per electron-hole pair, and the Fano factor, F. W exhibits discontinuities at the shell edges that follow the photoionization cross sections and decreases with increasing photon energy (from ~19 to 15 eV), with an asymptotic value of 15.2 eV at high energy. This decrease may contribute the initial rise in relative light yield with incident energy observed experimentally for CsI, thus suggesting that nonlinearity may be associated with intrinsic properties of the material at low energies. F is calculated to increase with increasing energy and has an asymptotic value of 0.28. A significant number of electron-hole pairs are produced through the different ionization channels of core shells and corresponding relaxation processes, which may explain why F is larger for CsI than for Si or Ge. Finally, the calculated spatial distributions show that the electron-hole pairs are primarily distributed along fast electron tracks. These spatial distributions constitute important input for large-scale simulations of electron-hole pair transport.

CsI.↗

Refine your search to explore more results.