Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “continuous”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Enabling technologies for the continuous electrically driven conversion of CO 2 and water to multi-carbon products at high current densities

Here, we demonstrate greatly improved conversion of CO 2 using a gas diffusion electrode (GDE) with flowing electrolyte configuration for CO 2 gas delivery in combination with a high surface area nickel phosphide electrocatalyst. This configuration achieves 40–50% selectivity for total carbon products over H 2 formation (HER) at total current densities ranging from 50 to 300 mA cm -2 . We developed a soft-templating method using CTAB detergent micelles for synthesis of phase-pure Ni 2 P, achieving a 260-fold larger surface area (BET) and porous sponge-like morphology that produces stable currents. This catalyst produces mainly one C-product, methylglyoxal (MG, C 3 H 4 O 2 ) with 38–47% overall selectivity, the highest reported selectivity for a 12-electron reduction product. The versatile soft-templating method for electrocatalyst synthesis uses low-temperature (185 °C) that is permissive for incorporation of co-catalysts that are otherwise destroyed by the high temperatures used in traditional solid-state synthesis (SSS). The non-porous Ni 2 P-SSS catalyst produces mainly H 2 at these current densities. Achieving these high currents and C/H selectivity benefits from use of hydrophobic polymers as co-catalyst binders (cationic = Nafion, anionic = PFAEM and neutral = PTFE) to improve CO 2 conversion. PFAEM is the better ionomer for the CO 2 RR at high current density, postulated as due to suppressing CO 2 conversion to inactive bicarbonate. Precipitation of the carbon products as a polycarbonate polymer occurs at high currents.

36 MATERIALS SCIENCE↗

Continuous flow photochemical synthesis of metal–ceramic composite microparticles

We developed a UV-assisted microfluidic system to synthesize FeCrAl–Al 2 O 3 composite microparticles for additive manufacturing. Here, the system ensures precise particle size, morphology, and elemental distribution control. Increasing the dispensing pressure while keeping the oil flow rate constant resulted in larger microparticles. Laser fusing revealed FeCrAl and Al 2 O 3 phases, showing their potential as feedstocks for 3D printed heterogeneous materials such as FeCrAl/Al 2 O 3 bi-phase materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Structures of the low frequency Alfven continuous spectrum and their consequences on MHD and micro-turbulence

We briefly discuss the unified theoretical framework that allows explaining a variety of experimental observations with one single 'fishbone-like' dispersion relation. We also point out the relationship of MHD and shear Alfven waves in the kinetic thermal ion frequency gap with microturbulence, Zonal Flows and Geodesic Acoustic Modes, emphasizing its importance in determining long time scale dynamic behaviors in burning plasmas.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The continued development of the Spallation Neutron Source external antenna H{sup -} ion source

The U.S. Spallation Neutron Source (SNS) is an accelerator-based, pulsed neutron-scattering facility, currently in the process of ramping up neutron production. In order to ensure that the SNS will meet its operational commitments as well as provide for future facility upgrades with high reliability, we are developing a rf-driven, H{sup -} ion source based on a water-cooled, ceramic aluminum nitride (AlN) plasma chamber. To date, early versions of this source have delivered up to 42 mA to the SNS front end and unanalyzed beam currents up to {approx}100 mA (60 Hz, 1 ms) to the ion source test stand. This source was operated on the SNS accelerator from February to April 2009 and produced {approx}35 mA (beam current required by the ramp up plan) with availability of {approx}97%. During this run several ion source failures identified reliability issues, which must be addressed before the source re-enters production: plasma ignition, antenna lifetime, magnet cooling, and cooling jacket integrity. This report discusses these issues, details proposed engineering solutions, and notes progress to date.

43 PARTICLE ACCELERATORS↗

Continuous gas discharge plasma with 200 K electron temperature

A very cold and collisional hot-filament discharge plasma is created in a vacuum chamber with an inner wall cooled by liquid nitrogen. The inner chamber (16.5 cm diameterx30 cm) has two negatively biased tungsten filaments for plasma generation and a Langmuir probe on axis for diagnostic measurements. With the wall at 140 K, 0.5-16 mA filament emission, and 1.6 mTorr carbon monoxide as the working gas, probe data give electron temperatures of 17-28 meV (197-325 K) with corresponding densities of 10{sup 8}-10{sup 9} cm{sup -3}. With He, Ar, H{sub 2}, and N{sub 2} at 140 K, the electron temperatures are >500 K. The lower electron temperature with CO is attributed to the asymmetric CO molecule having a larger cross section for electron excitation of rotational modes as a consequence of its dipole moment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Continuous-Discontinuous Model for Ductile Fracture

In this contribution, a continuum-dicontinuum model for ductile failure is presented. The degradation of material properties trough deformation is described by Continuum Damage Mechanics in a non-local integral formulation to avoid mesh dependence. In the final stage of failure, the damaged zone is replaced by a cohesive macro crack and subsequent traction-free macro crack for a more realistic representation of the phenomenon. The inclusion of the discontinuity surfaces is performed by the XFEM and Level Set Method and avoids the spurious damage growth typical of this class of models.

36 MATERIALS SCIENCE↗

A compact and continuously driven supersonic plasma and neutral source

A compact and repetitively driven plasma source has been developed by utilizing a magnetized coaxial plasma gun (MCPG) for diagnostics requiring deep penetration of a large amount of neutral flux. The system consists of a MCPG 95mm in length with a DN16 ConFlat connection port and an insulated gate bipolar transistor (IGBT) inverter power unit. The power supply consists of an array of eight IGBT units and is able to switch the discharge on and off at up to 10 kV and 600 A with a maximum repetitive frequency of 10 kHz. Multiple short duration discharge pulses maximize acceleration efficiency of the plasmoid. In the case of a 10 kHz operating frequency, helium-plasmoids in the velocity range of 20 km/s can be achieved.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Note: A helical velocity selector for continuous molecular beams

We report on a modern realization of the classic helical velocity selector for gas phase particle beams. The device operates stably under high vacuum conditions at rotational frequencies limited only by commercial dc motor capabilities. Tuning the rotational frequency allows selective scanning over a broad velocity band. The width of the selected velocity distributions at full-width-half-maximum is as narrow as a few percent of the selected mean velocity and independent of the rotational speed of the selector. The selector generates low vibrational noise amplitudes comparable to mechanically damped state-of-the-art turbo-molecular pumps and is therefore compatible with vibration sensitive experiments like molecule interferometry.

43 PARTICLE ACCELERATORS↗

Direct writing of ferroelectric domains on the x- and y-faces of lithium niobate using a continuous wave ultraviolet laser

Ferroelectric domain reversal has been achieved by scanning a tightly focused, strongly absorbed ultraviolet laser beam across the x- and y-faces of lithium niobate crystals. The domains were investigated by piezoresponse force microscopy. The emergence and width of any domain was found to depend on the scanning direction of the irradiating laser beam with respect to the polar z-axis. Full width and half width domains or no domain formation at all could be achieved for scanning along specific directions. We interpret the results by a direct correlation between the local temperature gradient and the resulting polarization direction.

36 MATERIALS SCIENCE↗

Continuous and discrete effective nuclear physics

We report on the recent developments of chiral effective field theory for nuclear physics based on Weinberg's power counting. Continuum calculations for deuteron photodisintegration, pion production in neutron-proton fusion and baryon-baryon interactions with strangeness S = -3 and S = -4 are discussed. The lattice formulation of the nuclear forces offers the possibility to study the nuclear many-problem. First results of this approach and some estimates for future simulations are shown.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Thermoforming of Continuous Fibre Reinforced Thermoplastic Composites

The introduction of new materials, particularly for aerospace products, is not a simple, quick or cheap task. New materials require extensive and expensive qualification and must meet challenging strength, stiffness, durability, manufacturing, inspection and maintenance requirements. Growth in industry acceptance for fibre reinforced thermoplastic composite systems requires the determination of whole life attributes including both part processing and processed part performance data. For thermoplastic composite materials the interactions between the processing parameters, in-service structural performance and end of life recyclability are potentially interrelated. Given the large number and range of parameters and the complexity of the potential relationships, understanding for whole life design must be developed in a systematic building block approach. To assess and demonstrate such an approach this article documents initial coupon level thermoforming trials for a commercially available fibre reinforced thermoplastic laminate, identifying the key interactions between processing and whole life performance characteristics. To examine the role of the thermoforming process parameters on the whole life performance characteristics of the formed part requires a series of manufacturing trials combined with a series of characterisation tests on the manufacturing trial output. Using a full factorial test programme and considering all possible process parameters over a range of potential magnitudes would result in a very large number of manufacturing trials and accompanying characterisation tests. Such an approach would clearly be expensive and require significant time to complete, therefore failing to address the key requirement for a future design methodology capable of rapidly generating design knowledge for new materials and processes. In this work the role of mould tool temperature and blank forming temperature on the thermoforming of a commercially available thermoplastic based composite laminate is investigated followed by post processed part characterization. Key findings include an optimized composite processing window, and the influence of raw material blank forming temperature and mould tool temperature on part crystallinity and flexural strength. This process study forms one element of a major project structure which has been designed to address the gap between design, analysis and manufacturing, using at its core, a digital framework for the creation and management of performance parameters related to the lifecycle performance of thermoplastic composite structures.

36 MATERIALS SCIENCE↗

Optimizing a microwave gas ion source for continuous-flow accelerator mass spectrometry

A 2.45 GHz microwave ion source coupled with a magnesium charge exchange canal (C x C) has been successfully adapted to a large acceptance radiocarbon accelerator mass spectrometry system at the National Ocean Sciences Accelerator Mass Spectrometry (AMS) Facility, Woods Hole Oceanographic Institution. CO{sub 2} samples from various preparation sources are injected into the source through a glass capillary at 370 {mu}l/min. Routine system parameters are about 120-140 {mu}A of negative {sup 12}C current after the C x C, leading to about 400 {sup 14}C counts per second for a modern sample and implying a system efficiency of 0.2%. While these parameters already allow us to perform high-quality AMS analyses on large samples, we are working on ways to improve the output of the ion source regarding emittance and efficiency. Modeling calculations suggest modifications in the extraction triode geometry, shape, and size of the plasma chamber could improve emittance and, hence, ion transport efficiency. Results of experimental tests of these modifications are presented.

43 PARTICLE ACCELERATORS↗

Refine your search to explore more results.