Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “adaptive imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Soot Imaging and Measurement

Soot, sometimes referred to as smoke, is made up primarily of the carbon particles generated by most combustion processes. For example, large quantities of soot can be seen issuing from the exhaust pipes of diesel-powered vehicles. Heated soot also is responsible for the warm orange color of candle flames, though that soot is generally consumed before it can exit the flame. Research has suggested that heavy atmospheric soot concentrations aggravate conditions such as pneumonia and asthma, causing many deaths each year. To understand the formation and oxidation of soot, NASA Lewis Research Center scientists, together with several university investigators, are investigating the properties of soot generated in reduced gravity, where the absence of buoyancy allows more time for the particles to grow. The increased time allows researchers to better study the life cycle of these particles, with the hope that increased understanding will lead to better control strategies. To quantify the amount of soot present in a flame, Lewis scientists developed a unique imaging technique that provides quantitative and qualitative soot data over a large field of view. There is significant improvement over the single-point methods normally used. The technique is shown in the sketch, where light from a laser is expanded with a microscope objective, rendered parallel, and passed through a flame where soot particles reduce the amount of light transmitted to the camera. A filter only allows light at the wavelength of the laser to pass to the camera, preventing any extraneous signals. When images of the laser light with and without the flame are compared, a quantitative map of the soot concentration is produced. In addition to that data, a qualitative image of the soot in the flame is also generated, an example of which is displayed in the photo. This technique has the potential to be adapted to real-time process control in industrial powerplants.

Source record↗

Quality Assessment of Landsat Surface Reflectance Products Using MODIS Data

Surface reflectance adjusted for atmospheric effects is a primary input for land cover change detection and for developing many higher level surface geophysical parameters. With the development of automated atmospheric correction algorithms, it is now feasible to produce large quantities of surface reflectance products using Landsat images. Validation of these products requires in situ measurements, which either do not exist or are difficult to obtain for most Landsat images. The surface reflectance products derived using data acquired by the Moderate Resolution Imaging Spectroradiometer (MODIS), however, have been validated more comprehensively. Because the MODIS on the Terra platform and the Landsat 7 are only half an hour apart following the same orbit, and each of the 6 Landsat spectral bands overlaps with a MODIS band, good agreements between MODIS and Landsat surface reflectance values can be considered indicators of the reliability of the Landsat products, while disagreements may suggest potential quality problems that need to be further investigated. Here we develop a system called Landsat-MODIS Consistency Checking System (LMCCS). This system automatically matches Landsat data with MODIS observations acquired on the same date over the same locations and uses them to calculate a set of agreement metrics. To maximize its portability, Java and open-source libraries were used in developing this system, and object-oriented programming (OOP) principles were followed to make it more flexible for future expansion. As a highly automated system designed to run as a stand-alone package or as a component of other Landsat data processing systems, this system can be used to assess the quality of essentially every Landsat surface reflectance image where spatially and temporally matching MODIS data are available. The effectiveness of this system was demonstrated using it to assess preliminary surface reflectance products derived using the Global Land Survey (GLS) Landsat images for the 2000 epoch. As surface reflectance likely will be a standard product for future Landsat missions, the approach developed in this study can be adapted as an operational quality assessment system for those missions.

Landsat↗

Land Surface Reflectances from Geostationary Sensors

GEONEX is a processing pipeline that produces a suite of satellite land surface products using data streams from the latest geostationary (GEO) sensors including the GOES016/ABI and the Himawari-8/AHI. The suite, created collaboratively by scientists from NASA and NOAA, includes top-of-atmosphere (TOA) reflectances, land surface reflectances (LSRs), vegetation indices, LAI/fPAR, and other downstream products. As a key component of the GEONEX product processing, we have adapted the Multi-Angle Implementation of Atmospheric Correction (MAIAC) algorithm to produce LSRs from the TOA data. Because the algorithm depends on building "stacks" of images, we first run internal geo-registration checks to ensure geo-spatial accuracy and consistency of the input (L1B) data before transferring them from the geostationary projection into a tile system in geographic grids. Scan-time is inferred from metadata and applied to calculate the sun-sensor angles for each grid cell. The MAIAC algorithm is run to detect clouds/shadows, estimate aerosol optical thickness (AOT), perform atmospheric corrections, and generate LSRs. We have processed 18-months (from 2016/04 onward) of AHI data over East Asia and Oceania at a 10-minute time step and 10-months (from 2018/01 onward) of ABI data over North and South Americas at a 15-minute time step. As a verification measure, we compare the GEONEX (AHI/ABI) surface reflectances with the standard MODIS products (MOD09GA) and the MODIS MAIAC products over pixels that have similar sun-view geometries. The results indicate general linear relationships between GEONEX and corresponding MODIS LSRs. In particular, the RMSEs between GEONEX and MOD09 data are comparable to those between MOD09 and MODIS MAIAC products, suggesting that the uncertainties of GEONEX LSRs fall into an acceptable range. However, direct comparisons of LSRs over pixels with different sun-view angles are not as straightforward and require more modeling efforts to correct the directional effects. Evaluation of such angular influences on the downstream products (e.g., vegetation indices) is also under investigation.

Geostationary satellite; Remote Sensing; Atmospher↗

The SMAP Level-4 ECO Product - Phase 1: Improving Vegetation Simulations Through Observation-Driven Parameter Estimation

Simulations of hydrological fields as well as water, energy and carbon fluxes from the land surface to the atmosphere are crucial for a wide range of applications, including agricultural advisories, forecasts of (short-term) atmospheric behavior and seasonal weather predictions including forecasts of extreme events, such as heatwaves or droughts. The NASA Soil Moisture Active Passive (SMAP) mission Level-4 (L4) Eco-Hydrology (ECO) project aims to improve modeled estimates of the terrestrial water, energy and carbon fluxes and states by developing a fully-coupled hydrology-vegetation data assimilation (DA) algorithm. The DA system is developed for the NASA Goddard Earth Observing System version 5 (GEOS-5) Catchment-CN land surface model, which combines land hydrology components of the GEOS-5 Catchment model with dynamic vegetation components of the Community Land Model version 4. Catchment-CN fully couples the terrestrial water, energy and carbon cycles, allowing feedbacks from the land hydrology to the biosphere and vice versa. For SMAP L4 ECO a calibration of the Catchment-CN vegetation parameterization against observations of the fraction of absorbed photosynthetically active radiation (FPAR) from the Moderate Resolution Imaging Spectroradiometer (MODIS) is implemented to improve the model's standalone skill. Next, the DA algorithm used to produce the SMAP L4 soil moisture product is adapted to Catchment-CN to assimilate SMAP brightness temperatures and inform the model's land hydrology component. The DA system is further extended to assimilate MODIS FPAR observations in order to constrain the model's dynamic vegetation component. In this presentation, we demonstrate that the Catchment-CN parameter calibration leads to more realistic vegetation simulations and reduces the root mean squared error between modeled and observed vegetation states across the model's various plant functional types. We also show that the assimilation of SMAP observations is able to improve the average correlation, bias and unbiased RMSE between the modeled surface and root zone soil moisture estimates, and ground observations from the SMAP core validation sites.

Kolassa, J.↗

Limitations and Feasibility of Mini X-Ray Devices in Space Environments

LIMITATIONS AND FEASIBILITY OF MINI X-RAY DEVICES IN SPACE ENVIRONMENTS As space exploration advances toward long-duration missions, reliable medical diagnostic tools become increasingly critical. The miniature x-ray (XR) technology demonstrations by the Exploration Medical Capability (ExMC) and the Exploration Medical Integrated Product Team (XMIPT) aim to assess the feasibility and utility of miniature XR devices in spaceflight. This abstract explores the limitations of current miniature XR systems, the challenges of training crew members, the potential role of clinical decision support systems (CDSS), and the feasibility of ground-based image interpretation. We also propose the integration of miniature XR into other ExMC efforts aimed at identifying the capabilities and resources needed for future exploration class missions. One of the primary challenges with miniature XR devices is the ability to achieve specific anatomical views, particularly in the confined and weightless conditions of a spacecraft. Operators may struggle to acquire diagnostic-quality images when space is limited for proper patient positioning and the volume of the imaging device. Since space radiation and detector limitations may further impact image quality, the flexibility of the operating procedures of these devices will be critical for their success in space applications. CHALLENGES IN TRAINING CREW TO OPERATE IMAGING DEVICES Training in the skills necessary to acquire diagnostic-quality scans may be a barrier for non-clinician crewmembers. The curriculum developed for crew medical officers (CMOs) will require simplification and adaptation to fit into the highly truncated pre-flight training period. Therefore, hands-on familiarization and simulation, both pre-flight and just-in-time training during missions, will be crucial to ensuring the crew can operate the devices in real-life situations. The ability to adjust acquisition parameters must be simplified or made automatic through exam selections on equipment user interfaces, and subject and operator positioning should be assisted with laser guidance and pictorial guides. POTENTIAL FOR CDSS OR ARTIFICIAL INTELLIGENCE (AI)-ASSISTED CDSS CDSS and AI-assisted CDSS offer significant promise in assisting crew members with limited medical training. These systems could provide real-time feedback on image quality and interpretation, helping to mitigate the risks of human error during space missions. Integrating procedural guidance tools, such as virtual and augmented reality, will support crewmembers in accurately positioning patients and obtaining high-quality images. However, the success of such systems will depend on the development of robust training datasets, integration with spaceflight-rated hardware, and the medical decision-making capabilities of operators. FEASIBILITY OF GROUND INTERPRETATION AND DATA TRANSMISSION Reliance on ground-based interpretation may prove difficult for acute care during exploration class-missions due to delays in transmission with increasing distance from Earth or complete communication blackout periods. In such instances where immediate interpretation for clinical intervention is required, crew must be able to interpret the images independently or utilize AI-based assistance to do so. File sizes for XR exams can also be large if numerous images are acquired and bandwidth constraints may limit data transmissions for both radiography and ultrasound exams. FUTURE WORK AND INTEGRATION INTO THE EVIDENCE LIBRARY Future work proposes integrating miniature XR devices into NASA’s Evidence Library to address medical conditions identified as significant contributors to crew morbidity and mortality. The possibility of combining miniature XR with other imaging modalities, such as ultrasound devices, is also under investigation. In conclusion, while miniature XR technology holds potential for extraterrestrial medical systems, there are significant challenges to overcome. Training, integration of AI tools, dedicated exam protocols for microgravity, and improved data transmission systems will be key to realizing the full benefits of miniature XR technology in space.

A M Nelson↗

Web Exploration Tools for a Fast Federated Optical Survey Database

We implemented several new web-based tools to improve the efficiency and versatility of access to the APS Catalog of the POSS I (Palomar Observatory-National Geographic Sky Survey) and its associated image database. The most important addition was a federated database system to link the APS Catalog and image database into one Internet-accessible database. With the FDBS, the queries and transactions on the integrated database are performed as if it were a single database. We installed Myriad the FDBS developed by Professor Jaideep Srivastava and members of his group in the University of Minnesota Computer Science Department. It is the first system to provide schema integration, query processing and optimization, and transaction management capabilities in a single framework. The attached figure illustrates the Myriad architecture. The FDBS permits horizontal access to the data, not just vertical. For example, for the APS, queries can be made not only by sky position, but also by any parameter present in either of the databases. APS users will be able to produce an image of all the blue galaxies and stellar sources for comparison with x-ray source error ellipses from AXAF (X Ray Astrophysics Facility) (Chandra) for example. The FDBS is now available as a beta release with the appropriate query forms at our web site. While much of our time was occupied with adapting Myriad to the APS environment, we also made major changes in Star Base, our DBMS for the Catalog, at the web interface to improve its efficiency for issuing and processing queries. Star Base is now three times faster for large queries. Improvements were also made at the web end of the image database for faster access; although work still needs to be done to the image database itself for more efficient return with the FDBS. During the past few years, we made several improvements to the database pipeline that creates the individual plate databases queries by StarBase. The changes include improved positions especially for galaxies, using a new median centroider and integrated magnitudes for galaxies with an improved density-to-intensity calibration with a "sky" background subtraction. In the original version of StarBase the object classification fainter than 19.5-20.0 mag., was an extrapolation of the networks trained on brighter objects. We have used a new catalog of galaxies at the NGP to train a neural network on objects fainter than 20th mag. This improved classification is used in the new version of StarBase. We have also added a FITS table option for the returned data from queries on the object catalog. The APS image database includes images in both colors so we have added a tool for querying the image database in both colors simultaneously. The images can be displayed in parallel or blinked for comparison.

Humphreys, Roberta M.↗

A Fast Implementation of the ISOCLUS Algorithm

Unsupervised clustering is a fundamental tool in numerous image processing and remote sensing applications. For example, unsupervised clustering is often used to obtain vegetation maps of an area of interest. This approach is useful when reliable training data are either scarce or expensive, and when relatively little a priori information about the data is available. Unsupervised clustering methods play a significant role in the pursuit of unsupervised classification. One of the most popular and widely used clustering schemes for remote sensing applications is the ISOCLUS algorithm, which is based on the ISODATA method. The algorithm is given a set of n data points (or samples) in d-dimensional space, an integer k indicating the initial number of clusters, and a number of additional parameters. The general goal is to compute a set of cluster centers in d-space. Although there is no specific optimization criterion, the algorithm is similar in spirit to the well known k-means clustering method in which the objective is to minimize the average squared distance of each point to its nearest center, called the average distortion. One significant feature of ISOCLUS over k-means is that clusters may be merged or split, and so the final number of clusters may be different from the number k supplied as part of the input. This algorithm will be described in later in this paper. The ISOCLUS algorithm can run very slowly, particularly on large data sets. Given its wide use in remote sensing, its efficient computation is an important goal. We have developed a fast implementation of the ISOCLUS algorithm. Our improvement is based on a recent acceleration to the k-means algorithm, the filtering algorithm, by Kanungo et al.. They showed that, by storing the data in a kd-tree, it was possible to significantly reduce the running time of k-means. We have adapted this method for the ISOCLUS algorithm. For technical reasons, which are explained later, it is necessary to make a minor modification to the ISOCLUS specification. We provide empirical evidence, on both synthetic and Landsat image data sets, that our algorithm's performance is essentially the same as that of ISOCLUS, but with significantly lower running times. We show that our algorithm runs from 3 to 30 times faster than a straightforward implementation of ISOCLUS. Our adaptation of the filtering algorithm involves the efficient computation of a number of cluster statistics that are needed for ISOCLUS, but not for k-means.

Memarsadeghi, Nargess↗

Universal crossed beam imaging studies of polyatomic reaction dynamics

The marriage between high level quantum calculations and experimental advances in laser technology, quantum state control, and detection techniques have opened the door to the study of molecular collision dynamics at a new level of detail. However, one current challenge lies in adapting these powerful strategies to address questions beyond the scope of the small ground state systems that have largely been the focus of reaction dynamics investigations to-date. For molecules with intermediate or large size (more than 6 atoms), lack of spectroscopic information and spectral congestion limit quantum state preparation, control and detection for experiment, and the large number of degrees of freedom of the system makes accurate quantum dynamics calculations prohibitively expensive. Nevertheless, studies of the chemical dynamics of such systems can reveal novel aspects of reactivity not anticipated based upon the behavior of smaller model systems. This Perspective will highlight applications of soft vacuum ultraviolet photoionization at 157 nm as a universal probe in combination with crossed beams and DC slice velocity map ion imaging to study bimolecular reaction dynamics of molecules of intermediate or large size, illuminated with support of high-level ab initio calculations. In this work, we report on the chemical dynamics of atomic oxygen or chlorine reactions with organic compounds: propanol isomers, alkylamines (N(CH 3 ) 3 and NH(CH 3 ) 2 ), and isobutene ((CH 3 ) 2 CCH 2 ) studied using this approach. The polyatomic radical products from the hydrogen abstraction process have been detected by 157 nm photoionization and their slice ion images embody translational energy and angular information that directly reflect the underlying collision dynamics. Various reaction mechanisms (such as direct abstraction and addition–elimination) along with the involvement of roaming dynamics and novel intersystem crossing pathways are presented. These demonstrate the power of this technique to reveal fundamentally new aspects of reaction dynamics that arise in larger reaction systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Final Report for Subcontract# B539681

This report summarizes the work performed under subcontract B539681. The scope of work described in the subcontract encompasses studies of fundamental research for fast ignition. The work statement from the from the original subcontract and the subsequent extension can be summarized in three major components: modeling of electron transport in experimental targets, development of diagnostics, and experimental implementation and analysis. All three of these areas have been addressed during the subcontract period, although the tasks detailed in the original subcontract were adapted to research conditions with guidance from the technical contact. The work performed in each of these areas is described. (1) Modeling of electron transport in experimental targets - Electron transport and x-ray generation in experimental targets were modeled with the Monte Carlo code Integrated Tiger Series 3.0 (ITS 3.0). This code package was also used to model the response of Bremsstrahlung spectrometer described in the paper. The modeling helped with target and spectrometer designs and was also used to interpret the measured data from the experiments. this work is coupled to the diagnostic development and experimental analysis and is described in the deliverable of the report. (2) Diagnostic Development - During the subcontract period a filter-stack Bremsstrahlung spectrometer using image plate dosimeters was developed, tested, and calibrated. The spectrometer design and sample data taken with the spectrometer was presented at the High Temperature Plasma Diagnostics conference (Albuquerque, NM 2008). The information was also subsequently published in the peer-reviewed conference proceedings (rev. Sci. Instrum. 79:10E305 (2008)). The diagnostic was fielded on over 10 experiments at the Jupiter Laser Facility at Lawrence Livermore and was also adapted for use on OMEGA EP, was discussed in the subcontract extension. A composition study of the image plate dosimeters was also disseminated as an internal LLNL technical memo. In addition, research was performed into two other diagnostics. Single Photon Counting using a CCD (Single Hit Spectrometer) is a well-established technique in the literature. The subcontractor assisted with implementation and calibration of the Single Hit Spectrometer and developed general use software for analysis of the output data. This software is currently being used by a number of collaborators at Lawrence Livermore. The development of a Single Hit Imager was also initially explored at the beginning of the subcontract period but, under direction of the technical contact, not further pursued in order to focus on the other priorities. (3) Experimental Implementation and Analysis - The subcontractor participated in over 10 separate 2-8 week experiments at the Jupiter Laser Facility at Lawrence Livermore. On many of these experiments, the diagnostics described above were fielded to take x-ray measurements for different physics goals, including those described in the original subcontract and for studies of diagnostic related issues for the National Ignition Facility. A series of experiments were carried out on planar foil targets to study the electrons generated in the relativistic laser plasma interaction under fast ignition relevant conditions. The data was analyzed with the Monte Carlo modeling described above.

42 ENGINEERING↗

Sequence length scaling in vision transformers for scientific images on frontier

Vision Transformers (ViTs) are pivotal for foundational models in scientific imagery, including Earth science applications, due to their capability to process large sequence lengths. While transformers for text have inspired scaling sequence lengths in ViTs, adapting these for ViTs introduces unique challenges. We develop distributed sequence parallelism for ViTs, enabling them to handle up to 1M tokens. Our approach, leveraging DeepSpeed-Ulysses and Long-Sequence-Segmentation with model sharding, is the first to apply sequence parallelism in ViT training, achieving a 94% batch scaling efficiency on 2,048 AMD-MI250X GPUs. Evaluating sequence parallelism in ViTs, particularly in models up to 10B parameters, highlighted substantial bottlenecks. We countered these with hybrid sequence, pipeline, and flash attention strategies, to scale beyond single GPU memory limits. Our method significantly enhances climate modeling accuracy by 20% in temperature predictions, marking the first training of a vision transformer model to convergence with a sequence length of 188K tokens, using full self-attention.

Tsaris, Aristeidis (aris) [ORNL] (ORCID:0000000277↗

Adaptive temperature profile control of a multizone crystal growth furnace

An intelligent measurement system is described which is used to assess the shape of a crystal while it is growing inside a multizone transparent furnace. A color video imaging system observes the crystal in real time, and determines the position and the shape of the interface. This information is used to evaluate the crystal growth rate, and to analyze the effects of translational velocity and temperature profiles on the shape of the interface. Creation of this knowledge base is the first step to incorporate image processing into furnace control.

Batur, C.↗

Feasibility study of real-time planning for stereotactic radiosurgery

Purpose: 3D rotational setup errors in radiotherapy are often ignored by most clinics due to inability to correct or simulate them accurately and efficiently. There are two types of rotation-related problems in a clinical setting. One is to assess the affected dose distribution in real-time if correction is not applied and the other one is to correct the rotational setup errors prior to the initiation of the treatment. Here, the authors present the analytical solutions to both problems. Methods: (1) To assess the real-time dose distribution, eight stereotactic radiosurgery (SRS) cases were used as examples. For each plan, two new sets of beams with different table, gantry, and collimator angles were given in analytical forms as a function of patient rotational errors. The new beams simulate the rotational effects of the patient during the treatment setup. By using one arbitrary set of beams, SRS plans were recomputed with a series of different combinations of patient rotational errors, ranging from (-5 Degree-Sign , -5 Degree-Sign , -5 Degree-Sign ) to (5 Degree-Sign , 5 Degree-Sign , 5 Degree-Sign ) (roll, pitch, and yaw) with an increment of 1 Degree-Sign and compared with those without rotational errors. For each set of rotational errors, its corresponding equivalent beams were computed using the analytical solutions and then used for dose calculation. (2) To correct for the rotational errors, two new sets of table, gantry, and collimator angles were derived analytically to validate the previously published derivation. However, in the derivation, a novel methodology was developed and two sets of table, gantry, and collimator angles were obtained in analytical forms. The solutions provide an alternative approach to rotational error correction by rotating the couch, gantry, and collimator rather than the patient. Results: For demonstration purpose, the above-derived new beams were implemented in a treatment planning system (TPS) to study the rotational effects on the SRS cases. For each case, the authors have generated ten additional plans that accounted for different rotations of the patient. They have found that rotations have an insignificant effect on the minimal, maximum, mean doses, and V{sub 80%} of the planning target volume (PTV) when the rotations were relatively small. This was particularly true for the small and near-spherical targets. They, however, did change V{sub 95%} significantly when the rotations approached 5 Degree-Sign . The theory has been validated with clinical SRS cases and proven to be practical and viable. The preliminary results demonstrate that the rotational effects are patient-specific and depend on several important factors, such as the PTV size, the PTV location, and the beam configuration. The solutions given in this paper are of great potential values in clinical applications. Conclusions: They have derived the analytical solutions to a new set of table, gantry, and collimator angles for a given treatment beam configuration as a function of patient rotational errors. One solution was used to assess the dosimetric effects of an imperfect patient setup and the other one was used to correct for the setup errors without rotating the patient. Compared to the widely adopted method of rotation effect assessment by importing the rotational CT images into TPS, the equivalent beam approach is simple and accurate. The analytical solutions to correcting for rotational setup errors prior to treatment were also derived. Based on the initial clinical investigations, they firmly believe that clinically viable real-time treatment planning and adaptive radiation therapy are feasible with this novel method.

60 APPLIED LIFE SCIENCES↗

Position detection accuracy of a novel linac-mounted intrafractional x-ray imaging system

Purpose: The authors have developed a system that monitors intrafractional target motion perpendicular to the treatment beam with the aid of radioopaque markers by means of separating kV image and megavoltage (MV) treatment field on a single flat-panel detector. Methods: They equipped a research Siemens Artiste linear accelerator (linac) with a 41 x 41 cm{sup 2} a-Si flat-panel detector underneath the treatment head. The in-line geometry allows kV (imaging) and MV (treatment) beams to share closely aligned beam axes. The kV source, usually mounted directly across from the flat-panel imager, was retracted toward the gantry by 13 cm to intentionally misalign kV and MV beams, resulting in a geometric separation of MV treatment field and kV image on the detector. Two consecutive images acquired within 140 ms (the first with MV-only and the second with kV and MV signal) were subtracted to generate a kV-only image. The images were then analyzed ''online'' with an automated threshold-based marker detection algorithm. They employed a 3D and a 4D phantom equipped with either a single radioopaque marker or three Calypso beacons to mimic respiratory motion. Measured room positions were either cross-referenced with a phantom voltage signal (single marker) or the Calypso system. The accuracy of the back-projection (from detected marker positions into room coordinates) was verified by a simulation study. Results: A phantom study has demonstrated that the imaging framework is capable of automatically detecting marker positions and sending this information to the tracking tool at an update rate of 7.14 Hz. The system latency is 86.9 {+-} 1.0 ms for single marker detection in the absence of MV radiation. In the presence of a circular MV field of 5 cm diameter, the latency is 87.1 {+-} 0.9 ms. The total RMS position detection accuracy is 0.20 mm (without MV radiation) and 0.23 mm (with MV). Conclusions: Based on the evaluated motion patterns and MV field size, the positional accuracy and system latency indicate that this system is suitable for real-time adaptive applications.

60 APPLIED LIFE SCIENCES↗

SU-E-T-784: Using MLC Log Files for Daily IMRT Delivery Verification

Purpose: To verify daily intensity modulated radiation therapy (IMRT) treatments using multi-leaf collimator (MLC) log files. Methods: The MLC log files from a NovalisTX Varian linear accelerator were used in this study. The MLC files were recorded daily for all patients undergoing IMRT or volumetric modulated arc therapy (VMAT). The first record of each patient was used as reference and all records for subsequent days were compared against the reference. An in house MATLAB software code was used for the comparisons. Each MLC log file was converted to a fluence map (FM) and a gamma index (γ) analysis was used for the evaluation of each daily delivery for every patient. The tolerance for the gamma index was set to 2% dose difference and 2mm distance to agreement while points with signal of 10% or lower of the maximum value were excluded from the comparisons. Results: The γ between each of the reference FMs and the consecutive daily fraction FMs had an average value of 99.1% (ranged from 98.2 to 100.0%). The FM images were reconstructed at various resolutions in order to study the effect of the resolution on the γ and at the same time reduce the time for processing the images. We found that the comparison of images with the highest resolution (768×1024) yielded on average a lower γ (99.1%) than the ones with low resolution (192×256) (γ 99.5%). Conclusion: We developed an in-house software that allows us to monitor the quality of daily IMRT and VMAT treatment deliveries using information from the MLC log files of the linear accelerator. The information can be analyzed and evaluated as early as after the completion of each daily treatment. Such tool can be valuable to assess the effect of MLC positioning on plan quality, especially in the context of adaptive radiotherapy.

60 APPLIED LIFE SCIENCES↗

Surface Remeshing with Robust High-Order Reconstruction

Remeshing is an important problem in variety of applications, such as finite element methods and geometry processing. Surface remeshing poses some unique challenges, as it must deliver not only good mesh quality but also good geometric accuracy. For applications such as finite elements with high-order elements (quadratic or cubic elements), the geometry must be preserved to high-order (third-order or higher) accuracy, since low-order accuracy may undermine the convergence of numerical computations. The problem is particularly challenging if the CAD model is not available for the underlying geometry, and is even more so if the surface meshes contain some inverted elements. We describe remeshing strategies that can simultaneously produce high-quality triangular meshes, untangling mildly folded triangles and preserve the geometry to high-order of accuracy. Our approach extends our earlier works on high-order surface reconstruction and mesh optimization by enhancing its robustness with a geometric limiter for under-resolved geometries. We also integrate high-order surface reconstruction with surface mesh adaptation techniques, which alter the number of triangles and nodes. We demonstrate the utilization of our method to meshes for high-order finite elements, biomedical image-based surface meshes, and complex interface meshes in fluid simulations.

Ray, Navamita↗

HiCIAO: A High-contrast Instrument for the Next Generation Subaru Adaptive Optics

HiCIAO (the High-Contrast Instrument with Adaptive Optics) is a high-contrast instrument for the 8.2-meter Subaru Telescope. The instrument is a near-infrared camera which benefits from a new adaptive optics (AO) system on the Subaru Telescope (AO188). The instrument realizes the high contrast with a help of AO188, a classical Lyot coronagraph, and three differential imaging techniques (polarimetric, spectral, and angular). Besides the differential imaging modes, HiCIAO also offers a normal imaging mode which covers 20''x20'' FOV with 0.''01 pixel{sup -1} resolution, and a pupil viewing mode for a precise alignment of the Lyot stop on the pupil image. The expected contrasts are 10{sup 5.5} at 1.''0 separation and 10{sup 4} at 0.''1 separation from a central star in the spectral differential imaging mode. The instrument is currently in its commissioning phase after the first-light observation in December 2008. This paper is an introductory review of the instrument.

79 ASTRONOMY AND ASTROPHYSICS↗

X-ray grating interferometer for materials-science imaging at a low-coherent wiggler source

X-ray phase-contrast radiography and tomography enable to increase contrast for weakly absorbing materials. Recently, x-ray grating interferometers were developed that extend the possibility of phase-contrast imaging from highly brilliant radiation sources like third-generation synchrotron sources to non-coherent conventional x-ray tube sources. Here, we present the first installation of a three grating x-ray interferometer at a low-coherence wiggler source at the beamline W2 (HARWI II) operated by the Helmholtz-Zentrum Geesthacht at the second-generation synchrotron storage ring DORIS (DESY, Hamburg, Germany). Using this type of the wiggler insertion device with a millimeter-sized source allows monochromatic phase-contrast imaging of centimeter sized objects with high photon flux. Thus, biological and materials-science imaging applications can highly profit from this imaging modality. The specially designed grating interferometer currently works in the photon energy range from 22 to 30 keV, and the range will be increased by using adapted x-ray optical gratings. Our results of an energy-dependent visibility measurement in comparison to corresponding simulations demonstrate the performance of the new setup.

43 PARTICLE ACCELERATORS↗

CHARACTERIZING COMPLEXITY IN SOLAR MAGNETOGRAM DATA USING A WAVELET-BASED SEGMENTATION METHOD

The multifractal nature of solar photospheric magnetic structures is studied using the two-dimensional wavelet transform modulus maxima (WTMM) method. This relies on computing partition functions from the wavelet transform skeleton defined by the WTMM method. This skeleton provides an adaptive space-scale partition of the fractal distribution under study, from which one can extract the multifractal singularity spectrum. We describe the implementation of a multiscale image processing segmentation procedure based on the partitioning of the WT skeleton, which allows the disentangling of the information concerning the multifractal properties of active regions from the surrounding quiet-Sun field. The quiet Sun exhibits an average Hoelder exponent {approx}-0.75, with observed multifractal properties due to the supergranular structure. On the other hand, active region multifractal spectra exhibit an average Hoelder exponent {approx}0.38, similar to those found when studying experimental data from turbulent flows.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Refine your search to explore more results.