Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “X-ray diffraction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Self‐Strain Suppression of the Metal‐to‐Insulator Transition in Phase‐Change Oxide Devices

Strongly correlated materials exhibiting phase transitions which can be controlled through external stimuli, such as electric fields, are promising for future computing technologies beyond conventional semiconductor transistors. Devices that take advantage of structural phase transitions have inherent built‐in memory, reminiscent of synapses and neurons, and are thus natural candidates for neuromorphic computing. Of particular interest are phase‐change oxides, which allow for control over the metal‐to‐insulator transition. Here, X‐ray nano‐diffraction structural imaging of micro‐devices fabricated with the archetypal phase‐change material vanadium sesquioxide (V 2 O 3 ) is reported. The devices contain a Ga ion‐irradiated region where the metal‐to‐insulator transition critical temperature is lowered, a useful feature for controlling neuron‐like spiking behavior. Results show that strain, induced by crystal lattice mismatch between the pristine and irradiated material, leads to a suppression of the metal‐to‐insulator‐transition. Suppression occurs within the irradiated region or along its edges, depending on the defect‐distribution and the size of the region. The observed self‐straining effect can extend to other phase‐change oxides and dominate as device dimensions are reduced and become too small to dissipate strain within the irradiated region. The findings are important for phase engineering in phase‐change devices and highlight the necessity to study phase transitions at the nanoscale.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Neutrons in Structural Biology: Challenges and Opportunities (Workshop Report)

Gaining a thorough understanding of biological systems requires building our knowledge about biological processes from the level of atoms and electrons, and up to whole organisms. Such comprehensive knowledge will allow for a predictive understanding of complex biological systems behavior. It will guide us in the design and development of novel therapeutics and vaccines to tackle existing health threats and to prepare for future pandemics, and it will provide information necessary to create new biomaterials and bio-inspired technologies through manipulation of biological macromolecules, their assemblies, single cells and even microorganisms. Reaching these goals will require a synergistic combination of multiple experimental techniques with molecular calculations and predictive simulations, and the design and development of new techniques and capabilities that bridge current knowledge and technology gaps. Neutron scattering provides unique information about the biomacromolecular structure and function and can play a major role in achieving these goals. A workshop was held to engage the scientific community in identifying pressing challenges in biochemistry, structural biology, enzymology and structure-guided drug design not solved with the current neutron scattering technologies or utilizing other structural biology techniques such as X-ray crystallography, NMR, and cryo-EM. The workshop brought together structural biology, biochemistry and computational experts, as well as early career researchers and students, creating a forum for discussing scientific advancement and collaboration. The workshop included a one-day satellite training workshop where graduate students and postdoctoral researchers were educated in the application of neutron crystallography and small-angle scattering in structural biology. Furthermore, the Instrument Scientific Advisory Board (ISAB) for the development of a macromolecular neutron diffractometer at ORNL’s Second Target Station was introduced at the workshop. The major outcome was that neutrons can provide atomic-level understanding of biomacromolecular structure, function and dynamics which is of paramount importance for addressing the identified challenges. Neutron crystallography, in particular, can resolve long-standing biochemical issues regarding enzyme function by delineating the underlying chemistry and can have a major impact on the design of small-molecule therapeutics, especially in combination with molecular computation (quantum chemistry and molecular dynamics simulations) and the emerging artificial intelligence (AI)-assisted drug design technologies. The unique properties of neutrons, including their high sensitivity to hydrogen and their non-destructive nature, make them ideal probes of biological matter. There is a palpable need in the scientific community to expand and enhance the impact of neutron sciences on biology. Neutron crystallography is the only structural biology method capable of determining positions of all hydrogen atoms in proteins, nucleic acids and their complexes at near-physiological temperatures and of unstable species at cryogenic temperatures. Moreover, neutron analysis is non-ionizing, non-destructive and does not perturb the structure or redox chemistry of active site metal centers and clusters in proteins, which can be invaluable for studying radiation-sensitive metalloprotein complexes. Further, neutron energies used in scattering applications are similar to atomic motions, permitting neutron spectroscopies to characterize the dynamics of biomacromolecules on the picosecond to microsecond timescales. The different sensitivities of neutrons to protium (H) and deuterium (D) isotopes of hydrogen allow enhanced visibility of specific parts of biological complexes through isotopic labeling. The impact of neutrons will be most powerful when neutron scattering is combined with complementary experimental techniques that use photons and electrons, and with high-performance computing. The interconnection and mutuality of the experimental and theoretical capabilities will drive discoveries in biological and health sciences to generate more complete picture of complex biological systems. The major limitation in the field of biological neutron crystallography has been signal-to-noise, demanding large samples that are difficult to produce for the majority of biomacromolecules and limiting the applicability of this technique in biological sciences. A neutron crystallography instrument at the Second Target Station will revolutionize biological science with neutrons by engaging a large scientific community of structural biologists, enabling successful neutron diffraction experiments from radically smaller biomacromolecular crystals, resolving unanswered biochemical questions, and meaningfully contributing to rational drug design. The meeting highlighted 10 grand challenges that will be addressed with this advanced capability over the next decade and beyond, and the recommendations required to help address them are given below.

59 BASIC BIOLOGICAL SCIENCES↗

Variable Bragg x-ray beam splitters

Beam splitters are utilized in a variety of advanced x-ray instruments and are essential for extending quantum optics techniques to x rays. A new fabrication method has produced thinned Bragg diffracting silicon devices with variable reflectivity and transmission coefficients and negligible absorption losses. Diffraction measurements confirm that silicon continues to exhibit perfect crystal diffraction even for thicknesses below two microns. Devices are machined from standard wafers, with the thinned regions contained within the robust frame of an unperturbed crystal for ease of handling.

Powers, L. T. (ORCID:000900047481248X)↗

First use of an InSb crystal for x-ray imaging spectroscopy of highly ionized tungsten in the Wendelstein 7-X stellarator

Advances in time and space resolved measurements of highly charged states of tungsten (W) through x-ray imaging spectroscopy have enabled investigation of impurity transport in the Wendelstein 7-X (W7-X) stellarator. The high-resolution x-ray imaging spectrometer (HR-XIS) system on W7-X utilizes the Bragg diffraction properties of a set of multiple crystals to measure a range of impurity emission lines within sections of the 1–7 Å wavelength range, including transitions of W. A new indium–antimonide crystal has been installed on the HR-XIS system to allow viewing of the 5.5–6.2 Å region focusing on emissions of W. Consequently, many bright W emission lines from W 40+ to W 47+ were observed in this wavelength range, both in plasmas with injected W and in those with only intrinsic W impurity sources, showing the high sensitivity of the diagnostic. Three W 46+ emissions correspond in wavelength and intensity with calculated photon emissivity coefficients and can be exploited for W transport and concentration applications in plasmas with T e ≳ 2.1 keV. Here, an estimate of the core W density behavior in two separate turbulence-reduced ‘high-performance’ (HP) discharges on W7-X is done using the 5.6893 Å W 46+ line. The n W behavior in HP scenarios can be explained by previous experimental results and neoclassical predictions.

XICS↗

Collaborative R&D with REEL Solar Inc (REEL) to Understand and Overcome Performance Limitations in CdTe Solar Cells: Cooperative Research and Development (Final Report)

This CRADA will focus on processing, advanced characterization, and testing of photovoltaic materials and devices to understand and improve REEL CdTe solar technology. This will include examining process variations and different buffer, absorber, and contact layers from REEL and NLR to maximize performance. The unique and diverse advanced characterization tools at NLR, such as time-resolved photoluminescence, capacitance-voltage measurements, electron beam scattered diffraction, cathodoluminescence, electron microscopy, TOF-SIMS, and other measurements will be applied to characterize REEL processing to improve understanding and guide experimental directions. Accelerated stability and potential induced degradation tests will be used to analyze metastability, short-and-long term degradation, and improve bankability. A second and major thrust this period will be joint development of Si/CdTe tandem solar cells to overcome industry wide terrestrial solar efficiency limits with the two lowest cost and manufacturable solar materials today. This will include developing novel transparent back contacts that can be incorporated into tandem structures and other novel solar applications, detailed analysis of designs and configurations for CdTe/Si tandem modules, and prototyping REEL CdTe Technology with Si bottom cells in tandem structures.

14 SOLAR ENERGY↗

Specimen Holder Design Improves Accuracy of X-Ray Powder Analysis

Specimen holder for X ray diffraction analysis presents the specimen to the incident X rays in a curvature. This permits the use of an X ray beam having a larger divergence angle, the beam intensity is increased, and the statistical accuracy of analysis is improved.

Mack, M.↗

Ray-tracing the convex curved crystal X-ray spectrograph

The convex curved crystal X-ray spectrograph has recently seen increasing use for the spectral analysis of transient plasmas. The present paper describes the calculation of ray paths through the spectrograph for both localized and extended sources. The method traces a ray from any given source point to its point of diffraction by the curved crystal and then to the imaging circle, where the image point is obtained. Application of the ray tracing method is made to some actual experimental configurations to obtain resolution values and source sizes. Wavelength calibrations are obtainable with the ray tracing method in advance of instrument construction.

Kastner, S. O.↗

Echelle spectrographs at grazing incidence

It is shown that by using the conical diffraction mount, existing echelle gratings can be used at grazing incidence to achieve high spectral resolution in the extreme UV and soft X rays. Design considerations for grazing incidence echelle spectrographs are examined, and two sample designs are discussed. The first, for use in the extreme UV, has a primary mirror and an entrance slit to the spectrograph. The system has a resolution of 10,000, operates at any wavelength longward of 100 A, and covers 30% of the spectrum at a single setting. The X-ray spectrograph uses objective gratings to obtain spectral resolution of 28,000 over any factor of 2 in. wavelength. It operates to wavelengths as short as 4 A.

Cash, W.↗

High efficiency spectrographs for the EUV and soft X-rays

The use of grazing incidence optics and reflection grating designs is shown to be a method that improves the performance of spectrographs at wavelengths shorter than 1200 A. Emphasis is laid on spectroscopic designs for X ray and EUV astronomy, with sample designs for an objective reflection grating spectrograph (ORGS) and an echelle spectrograph for wavelengths longer than 100 A. Conical diffraction allows operations at grazing incidence in the echelle spectrograph. In ORGS, the extreme distance of X ray objects aids in collimating the source radiation, which encounters conical diffraction within the instrument, proceeds parallel to the optical axis, and arrives at the detector. A series of gratings is used to achieve the effect. A grazing echelle is employed for EUV observations, and offers a resolution of 20,000 over a 300 A bandpass.

Cash, W.↗

Grazing incidence optics; Proceedings of the Meeting, Orlando, FL, Apr. 3, 4, 1986

Papers are presented on the diffraction-limited performance of grazing incidence optical systems; transverse ray aberrations of Wolter type 1 telescopes; hybrid X-ray telescope systems; surface characterization of grazing incidence optics in the extreme UV and X-ray regions; and the surface roughness properties of synchrotron radiation optics. Topics discussed include the simulation of free-abrasive grinding of grazing incidence mirrors with vertical-honing and flexible blades; mirrors for the Extreme Ultraviolet Explorer; the design and development of conical X-ray imaging mirrors; thermal loading considerations for synchrotron radiation mirrors; and grazing incidence optics for synchrotron radiation insertion-device beams. Consideration is given to the interpretation of glancing incidence scattering measurements; damage processes in short wavelength coated FEL optics; the replication of grain incidence optics; and the assembly and alignment of the Technology Mirror Assembly.

Osantowski, John F.↗

Design of an imaging microscope for soft X-ray applications

An imaging soft X-ray microscope with a spatial resolution of 0.1 micron and normal incidence multilayer optics is discussed. The microscope has a Schwarzschild configuration, which consists of two concentric spherical mirrors with radii of curvature which minimize third-order spherical aberration, coma, and astigmatism. The performance of the Stanford/MSFC Cassegrain X-ray telescope and its relevance to the present microscope are addressed. A ray tracing analysis of the optical system indicates that diffraction-limited performance can be expected for an object height of 0.2 mm.

Hoover, Richard B.↗

Organometallic chemical vapor deposition and characterization of ZnGe(1-x)Si(x)P2-Ge alloys on GaP substrates

In this paper, we report the epitaxial growth of ZnGe(1-x)Si(x)P2-Ge alloys on GaP substrates by open tube OMCVD. The chemical composition of the alloys characterized by energy dispersive X-ray spectroscopy shows that alloys with x up to 0.13 can be deposited on (001) GaP. Epitaxial growth with mirror smooth surface morphology has been achieved for x less than or equals to 0.05. Selected area electron diffraction pattern of the alloy shows that the epitaxial layer crystallizes in the chalcopyrite structure with relatively weak superlattice reflections indicating certain degree of randomness in the cation sublattice. Hall measurements show that the alloys are p-type, like the unalloyed films; the carrier concentration, however, dropped about 10 times from 2 x 10 exp 18 to 2 x 10 exp 17/cu cm. Absorption measurements indicate that the band tailing in the absorption spectra of the alloy has been shifted about 0.04 eV towards shorter wavelength as compared to the unalloyed material.

Xing, G. C.↗

Organometallic chemical vapor deposition and characterization of ZnGe(1-x)Si(x)P2-Ge alloys on GaP substrates

The epitaxial growth of ZnGe(1-x)Si(x)P2-Ge alloys on GaP substrates by open tube organometallic chemical vapor deposition (OMCVD) is reported. The chemical composition of the alloys characterized by energy dispersive X-ray spectroscopy shows that alloys with x up to 0.13 can be deposited on (001) GaP. Epitaxial growth with mirror smooth surface morphology was achieved for x less than or equal to 0.05. Transmission electron microscopy (TEM) micrographs of these alloys show specular epitaxy and the absence of microstructural defects indicating a defect density of less than 10(exp 7) cm(sup -2). Selected area electron diffraction pattern of the alloy shows that the epitaxial layer crystallizes in the chalcopyrite structure with relatively weak superlattice reflections indicating certain degree of randomness in the cation sublattice. Hall measurements show that the alloys are p-type, like the unalloyed films; the carrier concentration, however, dropped about 10 times from 2 x 10(exp 18) to 2 x 10(exp 17) cm(sup -3). Absorption measurements indicate that the band tailing in the absorption spectra of the alloy was shifted about 0.04 eV towards shorter wavelength as compared to the unalloyed material. Diodes fabricated from the n(+)-GaP/p-ZnSiP2-ZnGeP2-Ge heterostructure at x = 0.05 have a reverse break-down voltage of -10.8 V and a reverse saturation current density of approximately 6 x 10(exp -8) A/sq cm.

Xing, G. C.↗

Graded Multilayers not Required for Hard X-ray Imaging!

For a given X ray optic, a graded-multilayer coating extends the energy response to higher energies. However, this does not imply that graded multilayers are required for efficient hard X ray focusing. Indeed, smaller X ray optics using conventional coatings provide advantages -- namely, greater effective area per unit mass, less diffractive scattering by surface micro-roughness, and demonstrated feasibility - over larger optics coated with multilayers.

Weisskopf, M. C.↗

Refine your search to explore more results.