At least 1,801 records · Page 100

Feasibility of Lettuce Growth at Hypoxic and Sub-Ambient Total Gas Pressures

Lettuce (Lactuca saliva L. cv. 'Waldmann's Green') plants were grown (1) either from seed to 5 days old to study the effect of low atmospheric pressure (70 kPa) on their germination and early growth, or (2) until maturity at 30 days old to determine any long-term growth effects. The data were compared to plants grown in a second matching chamber which was maintained at ambient pressure (101 kPa) that served as a control. In other experiments, plants were grown at ambient pressure until maturity and then subjected to low atmospheric pressure for periods of 24 hours to determine possible effects of intermittent low pressure. The O2 and CO2 partial pressures in the low pressure chamber were adjusted to levels equal to those in the ambient pressure chamber to prevent differences in plant response which would have resulted from differences in the partial pressure of those gasses. The O2 partial pressure in the ambient chamber was maintained at 21 kPa and provision was made for additional CO2 during the fight phase. The germination rate and early seedling growth were insensitive to a low pressure environment. The rate of root elongation of plants grown at 70 kPa and at 101 kPa was also approximately the same. The rate of net carbon assimilation (per unit leaf area) of plants grown at low atmospheric pressure was unaffected at all growth stages even though plants grown at 70 kPa had slightly greater fresh and dry weights. There were consistent differences in assimilate partitioning, as shown by higher root/shoot ratios of plants grown at low pressure. Transpiration rates of plants grown until maturity under either constant or intermittent low pressure were reduced. Dark respiration rates of plants grown until maturity under either constant or intermittent low pressure were approximately 20% higher than the control plants.

Hoffman, Anne↗

Design and Fabrication of a Dielectric Total Internal Reflecting Solar Concentrator and Associated Flux Extractor for Extreme High Temperature (2500K) Applications

The Analex Corporation, under contract to the NASA Lewis Research Center (LeRC), Cleveland, Ohio, recently evaluated the feasibility of utilizing refractive secondary concentrators for solar heat receivers operating at temperatures up to 2500K. The feasibility study pointed out a number of significant advantages provided by solid single crystal refractive devices over the more conventional hollow reflective compound parabolic concentrators (CPCs). In addition to the advantages of higher concentration ratio and efficiency, the refractive concentrator, when combined with a flux extractor rod, provides for flux tailoring within the heat receiver cavity. This is a highly desirable, almost mandatory, feature for solar thermal propulsion engine designs presently being considered for NASA and Air Force thermal applications. Following the feasibility evaluation, the NASA-LeRC, NASA-Marshall Space Flight Center (MSFC), and Analex Corporation teamed up to design, fabricate, and test a refractive secondary concentrator/flux extractor system for potential use in the NASA-MSFC "Shooting Star" flight experiment. This paper describes the advantages and technical challenges associated with the design methodologies developed and utilized and the material and fabrication limitations encountered.

Soules, Jack A.↗

Comparison of Calculated and Experimental Total-Pressure Loss and Airflow Distribution in Tubular Turbojet Combustors with Tapered Liners

Incompressible-flow calculations were performed to determine the effects of combustor geometric and operating variables on pressure loss and airflow distribution in a tubular combustor with a tapered liner. The calculations include the effects of momentum transfer between annulus and liner gas streams, annulus wall friction, heat release, and discharge coefficients of liner air-entry holes. Generalized curves are presented which show the effects of liner-wall inclination, liner open hole area, and temperature rise across the combustor on pressure loss and airflow distribution for a representative parabolic liner hole distribution. A comparison of the experimental data from 12 tapered liners with the theoretical calculations indicates that reasonable design estimates can be made from the generalized curves. The calculated pressure losses of the tapered liners are compared with those previously reported for tubular liners.

Grobman, Jack S.↗

Evaluations of an Enhanced Total Hydrocarbon Analyzer With Complex Mixtures of Volatile Organic Compounds

From the earliest manned missions, the volatile organic compound (VOC) content of spacecraft air has been a concern because of a much greater potential for contamination than air in most terrestrial settings. First, the volume of air is small compared to the mass of man- made materials comprising the interior furnishings of the spacecraft. These man-made materials offgas VOCs trapped during manufacture. Second, the nitrogen fraction of the air is recycled. Any VOCs not scrubbed out with charcoal filters or aqueous condensate (mainly water expired by the crew) will accumulate in the air. Third, the crew emits metabolic VOCs. Fourth, experimental payloads can also offgas or accidentally release a VOC; in fact a major organic constituent of the atmosphere is the disinfectant isopropanol released from swabs used in medical experiments.

Cross, John H.↗

An Evaluation of Total Solar Reflectance and Spectral Band Ratioing Techniques for Estimating Soil Water Content

For several days in March of 1975, reflected solar radiation measurements were obtained from smooth and rough surfaces of wet, drying, and continually dry Avondale loam at Phoenix, Arizona, with pyranometers located 50 cm above the ground surface and a multispectral scanner flown at a 300-m height. The simple summation of the different band radiances measured by the multispectral scanner proved equally as good as the pyranometer data for estimating surface soil water content if the multispectral scanner data were standardized with respect to the intensity of incoming solar radiation or the reflected radiance from a reference surface, such as the continually dry soil. Without this means of standardization, multispectral scanner data are most useful in a spectral band ratioing context. Our results indicated that, for the bands used, no significant information on soil water content could be obtained by band ratioing. Thus the variability in soil water content should insignificantly affect soil-type discrimination based on identification of type-specific spectral signatures. Therefore remote sensing, conducted in the 0.4- to 1.0-micron wavelength region of the solar spectrum, would seem to be much More suited to identifying crop and soil types than to estimating of soil water content.

Reginato, R. J.↗

Total Lightning and Radar Storm Characteristics Associated with Severe Storms in Central Florida

This paper examines the three dimensional characteristics of lightning flashes and severe storms observed in Central Florida during 1997-1998. The lightning time history of severe and tornadic storms were captured during the on-going ground validation campaign supporting the Lightning Imaging Sensor (LIS) experiment on the Tropical Rainfall Measuring Mission (TRMM). The ground validation campaign is a collaborative experiment that began in 1997 and involves scientists at the Global Hydrology and Climate Center, MIT/Lincoln Laboratories, and the NWS Forecast Office at Melbourne, FL. Lightning signatures that may provide potential early warning of severe storms are being evaluated by the forecasters at the NWS/MLB office. Severe storms with extreme flash rates sometimes exceeding 300 per minute and accompanying rapid increases in flash rate prior to the onset of the severe weather (hall, damaging winds, tornadoes) have been reported by Hodanish et al. and Williams et al. (1998-this conference). We examine the co-evolving changes in storm structure (mass, echo top, shear, latent heat release) and kinematics associated with these extreme and rapid flash rate changes over time. The flash frequency and density are compared with the three dimensional radar reflectivity structure of the storm to help interpret the possible mechanisms producing the extreme and rapidly increasing flash rates. For two tornadic storms examined thus far, we find the burst of lightning is associated with the development of upper level rotation in the storm. In one case, the lightning burst follows the formation of a bounded weak echo region (BWER). The flash rates diminish with time as the rotation develops to the ground in conjunction with the decent of the reflectivity core. Our initial findings suggest the dramatic increase of flash rates is associated with a sudden and dramatic increase in storm updraft intensity which we hypothesize is stretching vertical vorticity as well as enhancing the development of the mixed phase region of the storm. We discuss the importance of these factors in producing both the observed extreme flash rates and the severe weather that follows in these storms and others to be presented.

Goodman, Steven J↗

Intercomparisons of Total Precipitable Water from Satellite and Other Long Term Data Sets

Global water vapor data sets from satellite (NVAP) and reanalysis (NCEP and DAO) are intercompared for a 5 year period (1988-1992). Global average indicates that the NCEP and DAO reanalyses are dryer than NVAP over much of the period. Spatial patterns of the NCEP/NVAP and DAO/NVAP differences show regional variations in the 60 month climatogical fields. For example, in the Eastern Pacific just south of the equator NVAP is much dryer than the NCEP and more moist than DAO. Rather large discrepancies exist in other regions as well. North Africa, Saudi Arabia, India, and Australia show that NVAP TPW values are more moist than the NCEP and DAO model analyses by 4-8 mm. In general, the NCEP and DAO exhibits a tendency to be dryer than NVAP over the tropical ocean region. Over the Americas little differences exist except over the west coast. The shapes of the differences fields over the Eastern Pacific region are significantly different between NCEP/NVAP and DAO/NVAP differences. Over South America and Central Africa, DAO TPW values are significantly higher than those of NVAP. These difference fields show monthly and seasonal variability as well. These results will be highlighted in the paper and on the poster.

Chang, Fong-Chiau↗

Development of the Double Etalon Fabry-Perot Interferometer for Determining Total and Tropospheric Ozone Concentrations

Measuring and understanding the distribution of ozone through the lower levels of Earth's atmosphere are high priorities in global change and climate research. Of particular interest now is the global distribution of ozone in the upper troposphere and lower stratosphere. Global coverage of the stratospheric ozone is feasible only via remote sensing instruments on a space-based platform. And though extensive monitoring tropospheric ozone is possible using instruments flown aboard conventional aircraft, a space-based system would be significantly less costly and provide information over a much broader area and produce more uniform coverage. Here we describe the prototype of an instrument being developed to monitor, from an orbiting spacecraft, the ozone found in Earth's upper troposphere and lower stratosphere. Our new spectrometer is an infrared Fabry-Perot interferometer which uses two synchrounously tuned etalons: a high resolution narrow band device and a lower resolution broader band filtering etalon. The prototype is a scanning device making use of nearly collimated input radiation and a single element detector. As presently configured, it is capable of providing a resolution better than 0.07/cm with a spectral band width approximately 5/cm wide and centered at 1054.7/cm. For the future space-based emission device a modification of the the prototype was to be made to employ innovative circle-to-line detector optics, those developed or in development at UM/SPRL, and a focal plane array detector. These enhancements would enable a simultaneous recording of the entire spectral range of interest, but with simple detection electronics and a significant gain in signal-to-noise over that of the scanning version.

Cook, William↗

Application of a Chemiluminescence Detector for the Measurement of Total Oxides of Nitrogen and Ammonia in the Atmosphere

By means of the thermal conversion of nitrogen dioxide to the nitric oxide, the chemiluminescent nitric oxide monitor, based on the nitric oxide plus ozone reaction, may be used for monitoring nitrogen dioxide plus nitric oxide (NO(x)). Under conditions previously described, ammonia is also converted to nitric oxide and therefore interferes. A metal surface, gold wool or stainless steel, operated at two different temperatures has been used to convert only nitrogen dioxide or nitrogen dioxide plus ammonia. Quantitative conversion of nitrogen dioxide to nitric oxide has been obtained at temperatures as low as 200 C. Conversion of ammonia is effected at temperatures of 300 C or higher. By the addition of a converter the basic nitric oxide monitor may be used for measuring NO(x) or NO(x) plus ammonia. As an alternate mode, for a fixed high temperature, a specific scrubber is described for removing NH3 without affecting NO2 concentrations.

Hodgeson, J. A.↗

Analysis, Repair, and Management of the Total Ozone Mapping Spectrometer Database

In the ensuing period we were able to demonstrate that the origin of these filamentous patterns resulted from the action of synoptic-scale vortical velocity field on the global-scale background gradient of ozone concentration in the meridional direction. Hyperbolic flow patterns between long-lived atmospheric vortices bring together air parcels from different latitudes, thus creating large gradients along the separatrices leaving the hyperbolic (stagnation) point. This result is further confirmed by the KL analysis of the ozone field in the equatorial region, where the background concentration gradient vanishes. The spectral slope in this region has been found to lie close to -1, in agreement with Batchelor's prediction. Another outcome of this result is that it at least provides indirect evidence about the kinetic energy spectrum of the atmospheric turbulence in the range of scales approximately 200 to 2000 km. Namely, Batchelor's analysis is based on the assumption that the velocity field is large-scale, that is the kinetic energy spectrum decays as O(k(sup -3)) or steeper. Since the scalar spectrum is confirmed, this also supports this form of the kinetic energy spectrum. The study of equatorial regions of TOMS data revealed the efficiency of the KL method is in detecting and separating a wave-like measurement artifact inherently present in the dataset due to the non-perfect correction for cross-track bias. Just two to three eigenfunctions represent the error, which makes it possible to enhance the data by reconstituting it from the data by eliminating the subspace of artifactual eigenfunctions. This represents a highly efficient means for achieving an improved rendering of the data. This has been implemented on the database. A wide range of techniques and algorithms have been developed for the repair and extension of the TOMS database.

Sirovich, Lawrence↗

Outgassing Total Mass Loss Obtained with Micro-CVCM and other Vacuum Systems

Several instruments including the Cahn Microbalance the Knudsen Cell, the micro-CVCM, and the vacuum Thermogravimetric Analyzer (TGA) were used in the testing of a graphite epoxy (GR/EP) composite that is proposed for use as a rigidizing element of an inflatable deployment system. This GR/EP will be cured in situ. The purpose of this testing is to estimate the gaseous production resulting from the curing of the GR/EP composite, to predict the resulting pressure, and to calculate the required venting. Every test was conducted under vacuum at 125 C for 24 hours. Upon comparison of the results, the ASTM E-595 was noted to have given readings that were consistently lower than those obtained using the other instruments, which otherwise provided similar results. The GR/EP was tested using several different geometric arrangements. This paper describes the analysis evaluating the molecular and continuum flow of the outgassing products issuing from the exit port of the ASTM E-595 system. The effective flow conductance provided by the physical dimensions of the vent passage of the ASTM E-595 system and that of the material sample among other factors were investigated to explain the reduced amount of outgassing released during the 24-hour test period

Scialdone, John J.↗

Material Total Mass Loss in Vacuum Obtained From Various Outgassing Systems

Several instruments including the Cahn Microbalance, the Knudsen Cell, the micro-CVCM, and the vacuum Thermogravimetric Analyzer (TGA) were used in the testing of a graphite/epoxy (GR/EP) composite that is proposed for use as a rigidizing element of an inflatable deployment system. This GR/EP will be cured in situ. The purpose of this testing is to estimate the gaseous production resulting from the curing of the GR/EP composite, to predict the resulting pressure, and to calculate the required venting. Every test was conducted under vacuum at 125 degrees C for 24 hours. Upon comparison of the results, the ASTM E-595 was noted to have given readings that were consistently lower than those obtained using the other instruments, which otherwise provided similar results. The GR/EP was tested using several different geometric arrangements. This paper describes the analysis evaluating the molecular and continuum flow of the outgassing products issuing from the exit port of the ASTM E-595 system. The effective flow conductance provided by the physical dimensions of the vent passage of the ASTM E-595 system and that of the material sample among other factors were investigated to explain the reduced amount of outgassing released during the 24-hour test period.

Scialdone, John↗

Highly Effective, Low Toxicity, Low Environmental Impact Total Flooding Fire Suppressants

Halon 1301 (CF3Br) has been used for decades as the primary fire suppression agent for areas where powder agents cannot be used because of concerns for sensitive equipment. Halon 1301 is an excellent extinguishing agent, effective at about 3% in air and quite non-toxic. It has an effective exposure limit much greater than its extinguishing concentration, so it can be used in normally occupied areas. The ability of a chemical to destroy stratospheric ozone is its ozone-depletion potential (ODP). ODP is the amount of ozone destroyed per pound of a chemical, relative to the standard CFC-11 with an ODP = 1.0. Because halons have been implicated in stratospheric ozone depletion, their production was stopped at the end of 1995 under the provisions of the Montreal Protocol plus later amendments. In the US, the Clean Air Act Amendments of 1990, Presidential directives, and DoD Directive 6050.9 implemented this phaseout. These regulations and penalties have provided strong incentives for US businesses to decrease CFC use. The Omnibus Budget Reconciliation Act of 1989 mandates high Federal taxes on CFCs and halons, designed to price them out of the market. The taxes also capture for the government the windfall profits that would otherwise go to producers as scarcity drives up prices. Several replacements have been developed for Halon 1301. One is carbon dioxide, which has been used as a firefighting agent for many years. However, a high concentration of carbon dioxide is necessary to inert fuels. The effective concentration for inerting with carbon dioxide is approximately 29%, which is above the concentration lethal to humans. HFC-227ea is being used extensively to replace Halon 1301 systems in nominally occupied areas and some normally unoccupied areas. However, since the effective concentration of HFC-227ea is about three to four times that of Halon 1301 the extinguishing systems have to be larger and new extinguishing systems have to be installed. HFC-125 is also being sold as an extinguishing agent (Nimitz). It has problems similar to HFC-227ea, with a greater concentration needed for effectiveness and the need to use a larger system. This is a particularly onerous penalty in aircraft and spacecraft, where weight and space are extremely important, and substitution is often impossible in existing aircraft due to space limitations.

Glass, S. M.↗

Total Optical Depth Analysis for NO2, O3 and Aerosols by a Multi-Filter Shadowband Radiometer

The main focus of this research is the retrieval of tropospheric aerosol information using a Multi-filter Rotating Shadowband Radiometer, Model MFR-7, placed on the roof of the Science Building at Medgar Evers College. This instrument makes precise measurements of atmospheric extinction of the direct solar beam simultaneously at six wavelengths (475, 500, 615, 670, 840 and 940 nm) at one minute intervals throughout the day. We are interested in measuring the changes in the optical depth of ambient aerosols, mass, effective particle size, aerosol size distribution, and chemical composition of ambient particulate matter in the Greater New York City Area. Results will be compared with data obtained by A. Lacis, B. Carlson and B. Cairns at the NASA Goddard Institute for Space Studies.

Williamson, Lorenzo↗

Outgassing Total Mass Loss Obtained with Micro-CVCM and Other Vacuum Systems

Several instruments including the Cahn Microbalance, the Knudsen Cell, the micro-CVCM, and the vacuum Thermogravimetric Analyzer (TGA) were used in the testing of a graphite epoxy (GR/EP) composite that is proposed for use as a rigidizing element of an inflatable deployment system. This GR/EP will be cured in situ. The purpose of this testing is to estimate the gaseous production resulting from the curing of the GR/EP composite, to predict the resulting pressure, and to calculate the required venting. Every test was conducted under vacuum at 125 C for 24 hours. Upon comparison of the results, the ASTM E-595 was noted to have given readings that were consistently lower than those obtained using the other instruments, which otherwise provided similar results. The GR/EP was tested using several different geometric arrangements. This paper describes the analysis evaluating the molecular and continuum flow of the outgassing products issuing from the exit port of the ASTM E-595 system. The effective flow conductance provided by the physical dimensions of the vent passage of the ASTM E-595 system and that of the material sample among other factors were investigated to explain the reduced amount of outgassing released during the 24-hour test period,

Scialdone, John↗

Absence of Change in Total Daily Energy Expenditure (EE(sub TD)) in Young and Mature Rats During 14 Days of Hypergravity

Effect of age on the response of EE(sub TD) to an increase in gravity was assessed in young (Y; 1.5 month old) and mature (M; 8 month old) Sprague-Dawley rats. Rats were implanted with transmitters to monitor activity, and metabolism was determined by the double labeled water technique. Daily food intake was measured. For each age, rats (n=8 per treatment) were exposed to centrifugation at 2G, or remained at 1G. There was a difference in EE(sub TD) between age groups, 182 plus or minus 11 and 143 plus or minus 5 kcal/kg/day in Y and M, respectively. This difference was attributed in part to a lower activity level in M animals, 48% of Y rats. After day 6 there was no effect on EE(sub TD) of exposure to 2G, or on food intake per 100g BW. Prior studies show a 20% increase in resting EE with hypergravity. In our study the level of activity was reduced to 41% of 1G in both age groups during 2G. For Y at 1G resting EE accounted for 78% of the EE(sub TD) and activity 22%, while at 2G resting EE was 96% of EE(sub TD) and activity 4%. M rats had similar changes. Independent of age, with exposure to hypergravity EE(sub TD) is maintained by behavioral changes.

Wade, C. E.↗

Annular and Total Solar Eclipses of 2003

On Saturday, 2003 May 31, an annular eclipse of the Sun will be visible from a broad corridor that traverses the North Atlantic. The path of the Moon's antumbral shadow begins in northern Scotland, crosses Iceland and central Greenland, and ends at sunrise in Baffin Bay (Canada). A partial eclipse will be seen within the much broader path of the Moon's penumbral shadow, which includes most of Europe, the Middle East, central and northern Asia, and northwestern North America. The trajectory of the Moon's shadow is quite unusual during this event. The shadow axis passes to the far north where it barely grazes Earth's surface. In fact, the northern edge of the antumbra actually misses Earth so that one path limit is defined by the day/night terminator rather than by the shadow's upper edge. As a result, the track of annularity has a peculiar "D" shape that is nearly 1200 kilometers wide. Since the eclipse occurs just three weeks prior to the northern summer solstice, Earth's northern axis is pointed sunwards by 22.8 deg. As seen from the Sun, the antumbral shadow actually passes between the North Pole and the terminator. As a consequence of this extraordinary geometry, the path of annularity runs from east to west rather than the more typical west to east. The event transpires near the Moon's ascending node in Taurus five degrees north of Aldebaran. Since apogee occurs three days earlier (May 28 at 13 UT), the Moon's apparent diameter (29.6 arc-minutes) is still too small to completely cover the Sun (31.6 arc-minutes) resulting in an annular eclipse.

Espenak, Fred↗

Total Ionizing Dose Effects in MOS Oxides and Devices

The development of military and space electronics technology has traditionally been heavily influenced by the commercial semiconductor industry. The development of MOS technology, and particularly CMOS technology, as dominant commercial technologies has occurred entirely within the lifetime of the NSREC. For this reason, it is not surprising that the study of radiation interactions with MOS materials, devices and circuits has been a major theme of this conference for most of its history. The basic radiation problem in a MOS transistor is illustrated. The application of an appropriate gate voltage causes a conducting channel to form between the source and drain, so that current flows when the device is turned on. In Fig. lb, the effect of ionizing radiation is illustrated. Radiation-induced trapped charge has built up in the gate oxide, which causes a shift in the threshold voltage (that is, a change in the voltage which must be applied to turn the device on). If this shift is large enough, the device cannot be turned off, even at zero volts applied, and the device is said to have failed by going depletion mode.

Oldham, Timothy R.↗