Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Thermal Storage System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Thermal conversion of unsolvated Mg(B3H8)2 to BH4- in the presence of MgH2

In the search for energy storage materials, metal octahydrotriborates, M(B3H8)n, n=1,2, are promising candidates but their synthesis suffers from residual solvents which tend to interact and greatly alter their decomposition mechanism. Therefore, we studied the thermal conversion of unsolvated Mg(B3H8)2 to BH4 -: as synthesized, and in the presence of MgH2. The conversion of our unsolvated Mg(B3H8)2 starts at ~100°C and yields ~22 wt% of BH4 - along with the formation of (closo-hydro)borates and volatile boranes. This loss of boron (B) is a sign of poor cyclability of the system. However, the addition of MgH2 to unsolvated Mg(B3H8)2 drastically increases the thermal conversion to 85-88wt% of BH4 - while simultaneously decreasing the amounts of B-losses. Our results strongly indicate that the presence of activated MgH2 substantially decreases the formation of (closohydro) borates and provides the necessary H2 for the B3H8-to-BH4 conversion. This is the first report of a metal octahydrotriborate system to selectively convert to BH4 - under moderate conditions of temperature (200°C) in less than 1h, making the MgB3H8-MgH2 system very promising for energy storage applications.

Gigante, Angelina↗

Overcharge investigation of large format lithium-ion pouch cells with Li(Ni 0.6 Co 0.2 Mn 0.2 )O 2 cathode for electric vehicles: Thermal runaway features and safety management method

The overcharge-induced thermal runaway features of large format commercial lithium-ion batteries with Li(Ni 0.6 Co 0.2 Mn 0.2 )O 2 (NCM622) cathode for electric vehicles under different current rates (C-rates) have been systematically studied at ambient temperature. The overcharge process is characterized as four stages. The temperature rise and the maximum temperature of the battery surface don't increase in proportion to the applied C-rates. However, with the increase of C-rates, the crest voltage of voltage curve rises linearly. When the voltage reaches approximately 5.1 V, a new voltage plateau appears in the cases below 2C. It is not sufficient that the temperature sensor is placed only near the terminal tab for most battery packs of EVs. In addition, the accumulated heat analysis demonstrates that side reactions dominate the temperature rise and contribute to most of the accumulated heat before thermal runaway. To mitigate the impact of overcharge and avoid the thermal runaway risk, a safety management method is proposed. Furthermore, the sharp drop in voltage before thermal runaway also provides a feasible approach to forewarn the users of the impending risk. These results are important for building safer batteries and providing information for the safety monitoring function of the battery management system (BMS).

25 ENERGY STORAGE↗

Stabilization and control of topological magnetic solitons via magnetic nanopatterning of exchange bias systems

Stabilizing and manipulating topological magnetic quasiparticles in thin films is of great interest for potential applications in data storage and information processing. Here, we present a strategy for stabilizing magnetic vortices and Bloch lines with controlled position, vorticity, and chirality in a continuous exchange bias system. By tailoring vectorially the unidirectional anisotropy of the system at the nanoscale, via thermally assisted magnetic scanning probe lithography, we show experimentally and via micromagnetic simulations the non-volatile creation of vortex-antivortex pairs. In addition, we demonstrate the deterministic stabilization of cross and circular Bloch lines within patterned Néel magnetic domain walls. This work enables the implementation of complex functionalities based on the control of tailored topological spin-textures in spintronic and magnonic nanodevices.

Magnetic ordering↗

Mechanical, Dynamic Mechanical and Thermal Properties of Banana Fiber/Recycled High Density Polyethylene Biocomposites Filled with Flyash Cenospheres

This study presents the preparation of Natural fiber-reinforced biocomposites based on Recycled High Density Polyethylene (RHDPE)/Banana Fiber (BF)/Fly ash Cenospheres (FACS) and aims to increase the economic value of these waste materials. Maleic anhydride grafted HDPE (MA-g-HDPE) was used as a compatibilizer to increase the dispersion of fibers into the polymer matrix as well as to increase the compatibility between the matrix and fillers. Variation in mechanical, thermal and dynamic mechanical properties with the addition of FACS in RHDPE/BF composites was investigated. It was observed that 7.5 wt% FACS, 30 wt% BF and 3 wt% MA-g-HDPE within RHDPE matrix resulted in an increase in tensile strength to 17%, tensile modulus to 188%, flexural strength to 38%, flexural modulus to 159% and hardness to 37% as compared with the RHDPE matrix. Significant enhancement in the thermal stability of the RHDPE/BF biocomposites was also observed in presence of FACS under thermogravimetric analysis. The morphology of the prepared biocomposites has been examined by using scanning electron microscopy. Dynamic mechanical analysis tests revealed an increase in storage and loss modulus of the biocomposite system. The use of such recycled material, agricultural and industrial wastes increased the properties of the final product suggesting their use to be a good alternative in the production of polymeric composites.

36 MATERIALS SCIENCE↗

New High-Strength Ni-based Alloys for High Temperature Service in Liquid Fluoride Salt Environments

The ever-increasing demand for higher system thermal efficiency necessitates the operation of power generation cycles and heat conversion systems for chemical processes at progressively higher temperatures. As the system operating temperature increases, fewer and fewer materials are available with the required mechanical properties and environmental compatibility. This dearth of materials is particularly acute in structural applications at temperatures above 700°C in liquid Fluoride Salt Cooled High-Temperature Reactors (FHRs) and Concentrated Solar Power (CSP) systems where liquid fluoride and/or liquid chloride salts are used for their high thermal capacity and low thermal conductivity to store and transport heat. It has been shown that fluorides and chlorides can degrade the properties of the material used for storage and transport due to corrosive effects thus affecting the performance and lifetime characteristics. Thus, materials used for storage and transport for fluoride/chloride-salt must at the minimum have good compatibility with the salt by exhibiting low corrosion rates at the required temperatures. In addition, since many of the components will be subject to stresses in service, they need to have sufficient strength to resist plastic deformation, and the resistance to time dependent creep deformation at these temperatures, and stress levels. Achieving the combination of these properties required for higher temperatures is particularly challenging considering traditionally, the expected lifetime of some of the components used in these systems are from 30 years (CSP) to 80 years (FHRs). Although 316 stainless steel and associated redox corrosion reduction techniques are being considered for use in the first generational systems, use of 316SS is limited to operating temperatures up to ~ 650°C, thereby resulting in lower reactor efficiencies. Hastelloy ® N, developed at ORNL in the 1950s-60s for molten salt service is currently the leading candidate FHR structural alloy but has inadequate creep properties at high temperatures. Using a computationally-guided approach, Oak Ridge National Laboratory had developed new high strength alloys strengthened by γ’ precipitates (about 2X the strength of Hastelloy ® N) in small laboratory-scale heats that show good resistance to corrosion by fluorides and improved creep rupture life at temperatures up to 850°C (U.S. Patent Application No. 13/833,357 entitled “High Strength Alloys for High Temperature Service in Liquid-Salt Cooled Energy Systems”- granted U. S. Patent No. 9,540,714).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A phenomenological force model of Li-ion battery packs for enhanced performance and health management

A 1-D phenomenological force model of a Li-ion battery pack is proposed to enhance the control performance of Li-ion battery cells in pack conditions for efficient performance and health management. The force model accounts for multiple swelling sources under the operational environment of electric vehicles to predict swelling-induced forces in pack conditions, i.e. mechanically constrained. The proposed force model not only incorporates structural nonlinearities due to Li-ion intercalation swelling, but also separates the overall range of states of charge into three ranges to account for phase transitions. Additionally an approach to study cell-to-cell variations in pack conditions is proposed with serial and parallel combinations of linear and nonlinear stiffness, which account for battery cells and other components in the battery pack. The model is shown not only to accurately estimate the reaction force caused by swelling as a function of the state of charge, battery temperature and environmental temperature, but also to account for cell-to-cell variations due to temperature variations, SOC differences, and local degradation in a wide range of operational conditions of electric vehicles. Considering that the force model of Li-ion battery packs can account for many possible situations in actual operation, the proposed approach and model offer potential utility for the enhancement of current battery management systems and power management strategies.

25 ENERGY STORAGE↗

A Safe Response to Renewable Energy Hazards

The International Association of Fire Fighters (IAFF) and Underwriters Laboratories, LLC (UL) in conjunction with UL Solutions initiated a joint project in 2022 under an agreement with the United States Department of Energy-Office of Energy Efficiency and Renewable Energy (DOE-EERE). This project focused on two separate and important initiatives related to energy efficiency in residential buildings. Initiative 1: Fire Performance on Energy Efficient Exterior Walls. Initiative 2: Firefighting Tactics in Residential Properties with Building Energy Storage Systems (BESS). The project’s first initiative addresses concerns surrounding new technologies with enhanced, energy-efficient exterior walls installed on residential properties. The concerns of fire rapidly traveling vertically up the exterior of these walls were examined. This addressed a growing concern from the first responder community that many times, the fires on the exterior of residential buildings have already evolved into an attic fire by the time of arrival – making it problematic to address the fire scenario. The test plan for Initiative 1 incorporated a modified version of an American Society for Testing and Materials (ASTM) test method, ASTM E2707, Standard Test Method for Determining Fire Penetration of Exterior Wall Assemblies Using a Direct Flame Impingement Exposure, as the foundation of the research. The test method involved a wall structure intended to represent retrofit construction to evaluate how fire would spread vertically or laterally. The second aspect of the UL-IAFF Project focuses on the fire service response to Residential Battery Energy Storage System (RBESS) incidents. These simulation tests were constructed in the large-scale fire test facility at UL Solutions’ Northbrook, IL campus. A baseline test was conducted that involved a test structure with no batteries—shelving units populated with standardized commodities, representing a typical garage with cellulosic and plastic contents. Three additional tests have been conducted to generate data with the contribution of energy storage system (ESS) batteries to compare fire and explosion hazards against the baseline test. Through this work, fire service tactical considerations can be explored. From the data, the team can determine 1) the visual indicators of a residential fire that has involved an RBESS (or, potentially, other large batteries) and 2) the impact of fire service-initiated ventilation of the structure on the fire conditions and explosion risks.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Heat pipes and their use in technology

Heat pipes may be employed as temperature regulators, heat diodes, transformers, storage batteries, or utilized for transforming thermal energy into mechanical, electric, or other forms of energy. General concepts were established for the analysis of the transfer process in heat pipes. A system of equations was developed to describe the thermodynamics of steam passage through a cross section of a heat pipe.

Vasilyev, L.↗

Phase 1 of the First Solar Small Power System Experiment (experimental System No. 1). Volume 3: Appendix E - N

The design of a solar electric power plant for a small community is reported. Topics covered include: (1) control configurations and interface requirements for the baseline power system; (2) annual small power system output; (3) energy requirements for operation of the collectors and control building; (4) life cycle costs and reliability predictions; (5) thermal conductivities and costs of receiver insulation materials; (6) transient thermal modelling for the baseline receiver/thermal transport system under normal and inclement operating conditions; (7) high temperature use of sodium; (8) shading in a field of parabolic collectors; and (9) buffer storage materials.

Clark, T. B.↗

International Space Station Evolution Data Book: Evolution Concepts - Volume 2

This report provides a focused and in-depth look at the opportunities and drivers for the enhancement and evolution of the International Space Station (ISS) during assembly and beyond the assembly complete stage. These enhancements would expand and improve the current baseline capabilities of the ISS and help to facilitate the commercialization of the ISS by the private sector. Volume 1 provides the consolidated overview of the ISS baseline systems; information on the current facilities available for pressurized and unpressurized payloads; and information on current plans for crew availability and utilization, resource timelines and margin summaries including power, thermal, and storage volumes; and an overview of the vehicle traffic model. Volume 2 includes discussions of advanced technologies being investigated for use on the ISS and potential commercial utilization activities being examined including proposed design reference missions (DRM's) and the technologies being assessed by the Pre-planned Program Improvement (P(sup 3) I) Working Group. This information is very high level and does not provide the relevant information necessary for detailed design efforts. This document is meant to educate readers on the ISS and to stimulate the generation of ideas for enhancement and utilization of the ISS, either by or for the government, academia, and commercial industry.

Jorgensen, Catherine A.↗

Comparison of Demand Response Performance with an EnergyPlus Model in a Low Energy Campus Building

We have studied a low energy building on a campus of the University of California. It has efficient heating, ventilation, and air conditioning (HVAC) systems, consisting of a dual-fan/dual-duct variable air volume (VAV) system. As a major building on the campus, it was included in two demand response (DR) events in the summers of 2008 and 2009. With chilled water supplied by thermal energy storage in the central plant, cooling fans played a critical role during DR events. In this paper, an EnergyPlus model of the building was developed and calibrated. We compared both whole-building and HVAC fan energy consumption with model predictions to understand why demand savings in 2009 were much lower than in 2008. We also used model simulations of the study building to assess pre-cooling, a strategy that has been shown to improve demand saving and thermal comfort in many types of building. This study indicates a properly calibrated EnergyPlus model can reasonably predict demand savings from DR events and can be useful for designing or optimizing DR strategies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Overview of Proposed ISRU Technology Development

ISRU involves any hardware or operation that harnesses and utilizes in-situ resources (natural and discarded) to create products and services for robotic and human exploration: Assessment of physical, mineral chemical, and volatile water resources, terrain, geology, and environment (orbital and local). Production of replacement parts, complex products, machines, and integrated systems from feedstock derived from one or more processed resources. Civil engineering, infrastructure emplacement, and structure construction using materials produced from in situ resources. Radiation shields, landing pads, roads, berms, habitats, etc. Generation and storage of electrical, thermal, and chemical energy with in situ derived materials. Solar arrays, thermal wadis, chemical batteries, etc. ISRU is a disruptive capability: Enables more affordable exploration than todays paradigm. Allows more sustainable architectures to be developed. Understand the ripple effect in the other Exploration Elements: MAV: propellant selection, higher rendezvous altitude (higher DV capable with ISRU propellants). EDL: significantly reduces required landed mass. Life Support: reduce amount of ECLSS closure, reduce trash mass carried through propulsive maneuvers. Power: ISRU drives electrical requirements, reactant and regeneration for fuel cells for landers, rovers, and habitat backup. Every Exploration Element except ISRU has some flight heritage (power, propulsion, habitats, landers, life support, etc.) ISRU will require a flight demonstration mission on Mars before it will be included in the critical path. Mission needs to be concluded at least 10 years before first human landed mission to ensure lessons learned can be incorporated into final design. ISRU Formulation team has generated a (still incomplete) list of over 75 technical questions on more than 40 components and subsystems that need to be answered before the right ISRU system will be ready for this flight demo.

Mars exploration↗

Study of radioisotope safety devices for electric propulsion system, Volume 1: Summary report

A new reference design was prepared for the 5 kW(e) thermionic power supply. The safety equipment in this design is a passive containment system which does not rely on the operation of any mechanisms such as a launch escape rocket or deployment of parachutes. It includes: (1) a blast shield to protect against the explosion of the launch vehicle; (2) a combination of refractory thermal insulation and heat storage material to protect against a sustained launch pad fire; (3) a reentry body with a spherical nose and a large conical flare at the aft end to stabilize the reentry attitude and lower the terminal velocity in air; (4) composite graphite thermal protection to sustain the reentry heat pulse; (5) crushable honeycomb behind the nose to limit the deceleration of the radioisotope source due to impact on land at terminal velocity; (6) a double-walled secondary containment vessel surrounding the isotopic capsules; (7) neutron shielding to reduce external dose rates; (8) an auxiliary cooling system employing redundant heat pipes to remove the radioactive decay heat from the heat source and reject it to the surroundings or to a forced convection loop.

Bradshaw, G. B.↗

Techno-Economic Assessment of Residential Heat Pump Integrated with Thermal Energy Storage

Phase change material (PCM)-based thermal energy storage (TES) can provide energy and cost savings and peak demand reduction benefits for grid-interactive residential buildings. Researchers established that these benefits vary greatly depending on the PCM phase change temperature (PCT), total TES storage capacity, system configuration and location and climate of the building. In this study, preliminary techno-economic performance is reported for a novel heat pump (HP)-integrated TES system using an idealized approach. A simplified HP-TES was modeled for 1 year of space heating and cooling loads for a residential building in three different climates in the United States. The vapor compression system of the HP was modified to integrate with TES, and all heat transfer to and from the TES was mediated by the HP. A single PCM was used for heating and cooling, and the PCT and TES capacity were varied to observe their effects on the building’s energy consumption, peak load shifting and cost savings. The maximum reduction in electric consumption, utility cost and peak electric demand were achieved at a PCT of 30 °C for New York City and 20 °C for Houston and Birmingham. Peak energy consumption in Houston, New York City, and Birmingham was reduced by 47%, 53%, and 70%, respectively, by shifting peak load using a time-of-use utility schedule. TES with 170 MJ storage capacity allowed for maximum demand shift from on-peak to off-peak hours, with diminishing returns once the TES capacity equaled the daily building thermal loads experienced during the most extreme ambient conditions.

25 ENERGY STORAGE↗

Fiber Optic Sensing Technologies for Battery Management Systems and Energy Storage Applications

Applications of fiber optic sensors to battery monitoring have been increasing due to the growing need of enhanced battery management systems with accurate state estimations. The goal of this review is to discuss the advancements enabling the practical implementation of battery internal parameter measurements including local temperature, strain, pressure, and refractive index for general operation, as well as the external measurements such as temperature gradients and vent gas sensing for thermal runaway imminent detection. A reasonable matching is discussed between fiber optic sensors of different range capabilities with battery systems of three levels of scales, namely electric vehicle and heavy-duty electric truck battery packs, and grid-scale battery systems. The advantages of fiber optic sensors over electrical sensors are discussed, while electrochemical stability issues of fiber-implanted batteries are critically assessed. This review also includes the estimated sensing system costs for typical fiber optic sensors and identifies the high interrogation cost as one of the limitations in their practical deployment into batteries. Finally, future perspectives are considered in the implementation of fiber optics into high-value battery applications such as grid-scale energy storage fault detection and prediction systems.

25 ENERGY STORAGE↗

Low‐cost, Long Duration Electrical Energy Storage Using a CO 2 ‐based Pumped Thermal Energy Storage

The increasing deployment of non‐dispatchable, intermittent renewable energy generation sources to address climate change is placing pressure upon electrical grids’ ability to match supply with demand. The need to deploy large quantities of long duration energy storage assets is rapidly approaching, and innovative methods of energy storage that are low cost, efficient, safe and environmentally benign are needed urgently. CO 2 ‐based Pumped Thermal Energy Storage (PTES) is a low cost, efficient and environmentally safe energy storage technology. PTES uses an electrically‐driven CO 2 heat pump to charge thermal reservoirs that are later used as resources to generate electricity using a CO 2 heat engine. In this program, Echogen and collaborators refined the design of a utility‐scale CO 2 PTES system and demonstrated key technologies that will be required for successful commercial development in a laboratory‐scale system. Component and system‐level performance was evaluated over multiple charge/discharge cycles, with favorable results. Echogen is continuing to develop and commercialize this technology at utility scale.

25 ENERGY STORAGE↗

Abuse Response of 18650 Li-Ion Cells with Different Cathodes Using EC:EMC/LiPF6 and EC:PC:DMC/LiPF6 Electrolytes

We report Lithium-Ion batteries are being considered as a high-energy density replacement for Nickel Metal Hydride (NiMH) batteries in Hybrid Electric Vehicles (HEVs) and in the new Plug-In Hybrids (PHEVs). Although these cells can result in significant reduction in weight and volume, they have several safety related issues that still need to be addressed. We report here on the thermal response of Li-ion cells specifically assembled in our laboratory to test new materials, electrolytes and additives. Finally, improvements in the thermal abuse tolerance of cells are reported and discussed in terms of the need for overall battery system safety.

25 ENERGY STORAGE↗

Thermal Cycle and Capacitance Testing of Mezzo Industries Phase Changer Material Heat Capacitor

Effective Thermal management is essential for the safety and performance of human spacecraft, especially during long-duration missions with fluctuating heat loads. Phase Change Material (PCM) heat exchangers offer a compact, efficient solution by storing and releasing thermal energy through latent heat during phase transitions. This allows PCM systems to buffer transient thermal loads without immediate heat rejection, reducing the need for oversized radiators – particularly critical during ascent and re-entry when radiators are stowed. By maintaining stable temperatures in crew cabins and equipment bays, PCM technology enhances crew comfort, protects sensitive systems, and supports long-term mission sustainability with minimal mass and volume impact. A phase change material heat capacitor prototype, designed and built under a NASA Small Business Innovation Research grant by Mezzo Technologies, utilizes a laser welding microtube manufacturing process that promises increased reliability and performance over current manufacturing methods like brazing. This heat exchanger was tested through coolant thermal cycling within the expected flow rates and temperature range of the Orion spacecraft, the crewed spacecraft taking NASA astronauts to the moon under the Artemis Program. The useful heat storage capacitance was measured and compared to Orion spacecraft requirements.

Active Thermal Control Systems↗

Refine your search to explore more results.