Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Technology data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

UNH TDP - Voltsys Raw Data and Processing Scripts - Fall 2021

This submission contains raw Voltsys rectifier data and processing scripts associated with MHKDR submission 394 (UNH TDP - Concurrent Measurements of Inflow, Power Performance, and Loads for a Grid-Synchronized Vertical Axis Cross-Flow Turbine Operating in a Tidal Estuary, DOI: 10.15473/1973860) from the University of New Hampshire and Atlantic Marine Energy Center (AMEC) turbine deployment platform. The user is directed to the MHKDR submission 394 for relevant context and detail of this deployment; see link below. The 394_READ_ME file here provides the description from that submission for quick reference. The READ_ME file for this specific instrument from the 394 submission is also available here. This submission contains a zipped folder structure containing raw data in its original format and MATLAB (2019a) processing scripts used to process and manipulate the data into its final form. The final data products are submitted in the 394 submission.

16 TIDAL AND WAVE POWER↗

TEAMER - AquaHarmonics High Fidelity WEC Sim PTO and Control Model Validation, Test Logs and Results

Collaborative effort between AquaHarmonics, Sandia National Laboratories (SNL), and the National Renewable Energy Laboratory (NREL) to revise and validate Aquaharmonics' full wave to wire model, allowing for reduced uncertainty and increased understanding of design requirements of a utility scale wave energy converter (WEC). SNL and NREL in collaboration with AquaHarmonics, will set up and run WEC Simulator (WEC-Sim) models of the AquaHarmonics WEC, building off past model developments for inclusion of custom PTO (power take-off) dynamics. The intent is to review, update, and verify or validate a new WEC-Sim model against wave tank experimental data. Furthermore, the WEC-Sim model will be coupled to an energy storage system model to better understand the wave-to-wire functionality. This data set is described in the "Test Log" excel file. Please refer to that document for details on each specific test date/time, constraint parameters and model hardware setup details. Sim model can be found in the associated MHKDR link below.

16 TIDAL AND WAVE POWER↗

Ocean Energy Sandia TEAMER WEC Simulation Results

Computational fluid simulations for wave energy converters and supporting materials from Ocean Energy's WEC Buoy TEAMER project in collaboration with Sandia National Laboratories. Each file includes images and video of simulation along with the simulation files for the case. The videos and images include air and water simulations of the buoy in 2D and 3D views. Data spreadsheets of the simulation outputs are also included in the files. The data are represented as different cases in which the wave height(Hs) and peak period(Tp) were different.

16 TIDAL AND WAVE POWER↗

MASK4 Test Campaign for Sandia WaveBot Device

This data and report details the findings from a wave tank test focused on production of useful work of a wave energy converter (WEC) device. The experimental system and test were specifically designed to validate models for power transmission throughout the WEC system. Additionally, the validity of co-design informed changes to the power take-off (PTO) were assessed and shown to provide the expected improvements in system performance. These data describe the "MASK4" wave tank test of the Sandia WaveBot device. The WaveBot device has been tested a number of times in different permutations at the US Navy's Maneuvering and Sea Keeping (MASK) basin. Each test in this series is referred to as MASK1, MASK2, etc. The WaveBot device was first tested in one degree of freedom (heave) in 2016. This MASK1 test focused primarily on system identification and modeling. After MASK1, major modifications were performed to improve the overall real-time control and measurement system, improve the heave drive train, and add surge and pitch degrees of freedom. The second set of testing, which was broken up in to two stages: MASK2A and MASK2B, focused on bench testing and closed-loop control performance as well as nonlinear modeling. MASK3 then focused on multi-input, multi-output modeling and control for maximization of electrical power. The attached report presents the results from MASK4, which focuses on detailed modeling of the power conversion chain and validation co-design principles by way of the introduction of a magnetic spring. The test log, report, and data from the MASK4 test of the WaveBot augmented with a tunable magnetic spring. Processing codes can be found at the Github link below.

16 TIDAL AND WAVE POWER↗

MBARI-WEC September and October 2022 Field Data

This data is needed to simulate a model of the MBARI-WEC (Monterey Bay Aquarium Research Institute, Wave Energy Converter device) in a simulation environment (e.g. Gazebo) for 56 observation dates in the time between September and October 2022, and to compare the simulation outputs to the corresponding field data of the physical MBARI-WEC. There were 50 observations chosen in Sept and 6 observations in Oct. To help understand terms below, a summary of the system can be found at the github link in the downloads section below. The Gazebo MBARI-WEC model is also provided, should users wish to simulate using this platform. There are 4 *mat files included. ................................................................................................................................................................................................................................... Spectrum and Simulation Inputs: September2022_spectrum_siminputs.mat and October2022_spectrum_siminputs.mat has data needed for simulation inputs in table format. These include the ocean spectrum for an observation and operating parameters of the MBARI-WEC during that observation. They are organized as rows representing an observation and columns representing data. For example, for the September *mat there are 50 rows. The first 7 columns are Datetime, sig_waveheight, peak_period, mean_period, heaveconedoor_status, pistonpos_mean, and scale_factor: - Datetime is the date and time the observation occurred in PST - sig_waveheight is the significant wave height of the ocean spectrum during that observation in meters - peak_period is the peak period of the ocean spectrum during that observation in seconds - mean_period is the mean period of the ocean spectrum during that observation in seconds - heaveconedoor_status is the status of the heave cone doors where 0 represents the doors are open and 1 represents they are closed - pistonpos_mean is the mean position of the PTO ram (piston) in meters - scale_factor is an additional factor of 0.5 --1.4 applied to a default damping relationship The next columns are data needed to represent the ocean spectrum. First are the frequencies [Hz] labeled as "f0-f38", then the variance density [m2/Hz] labeled as "vardens0-vardens38". October2022_spectrum_siminputs.mat follows as a similar format as above, but includes a larger amount of ocean spectrum frequencies and variance density elements. ................................................................................................................................................................................................................................... Field data: The field data is found in MBARIWEC_septdata.mat and MBARIWEC_octdata.mat for the observations of September and October, respectively. These contain data in a struct format. The struct contains the following fields for each observation: PC_BattCurr, PC_LoadCurr, PC_RPM, PC_Voltage, SC_Range, SC_Velocity, DateTime, where: - PC_BattCurr is the current flowing to or from the onboard batteries in Amps - PC_LoadCurr is the current flowing to the load dump in Amps - PC_RPM is the electric/hydraulic motor shaft speed (directly coupled) in RPM - PC_Voltage is the bus voltage at the power converter in Volts - SC_Range is the PTO ram (piston) position in meters where 0 is fully retracted and 2.03 is fully extended - SC_Velocity is the PTO ram (piston) velocity in meters/sec - DateTime is the date and time of the sampled field data in each observation in PST - Electric Power is equal to: PC_Voltage*(PC_BattCurr + PC_LoadCurr) in Watts For example, upon loading MBARIWEC_octdata.mat, the aforementioned fields would be loaded, each with {6x1} cells for the 6 observations chosen in October. Within the first cell of e.g. SC_Range would be sampled data representing the field data of the MBARIWEC PTO piston position for say, one hour, of the first October observation. The corresponding field DateTime would...

16 TIDAL AND WAVE POWER↗

TEAMER: Biofouling Analysis for Wave Energy Piston Design - Load Cell Data

Biofouling and corrosion are a major concern for all ocean-deployed components, especially when mechanical motion is involved. Triton has developed the concept of a biofouling mitigation seal as part of the piston sealing assembly for the Triton Wave Energy Converter (TSI-WEC). This mitigation seal has the purpose of preventing the formation of a biofilm on the inside of the piston cylinder. It is hypothesized that the prevention of a biofilm will reduce the amount of macro-biofouling that can occur in the piston assembly. The mitigation seal can also reduce the wear on the main dynamic seal, helping to maintain smooth operation and water-tightness. The cylinder is made from a thermoset composite epoxy, which is resistant to corrosion. However, no studies have researched the material's performance with biofouling. Triton placed two prototype Power Take-Off (PTO) assemblies in a PNNL biofouling tank, one with a biofouling mitigation seal and one without, allowing for an evaluation of seal effectiveness at the prevention of biofouling. In actual WEC operation, wave action would react against the piston, which would drive the linear actuator and electric generator, providing electrical power. In the test setup, this was reversed; a linear actuator was powered to drive the piston in a consistent motion within the cylinder. There are two assemblies: one has a biofouling mitigation seal, the other (control) does not. The following data encompasses a 4 month test period, with load cells being used to monitor piston friction force. Results from this testing will be used to improve seal design and material selection, mitigating risk of premature failure during open water testing and evaluation. This project is part of the TEAMER RFTS 3 (request for technical support) program.

16 TIDAL AND WAVE POWER↗

Coldstream 1MH Well

Computed tomography scans and core log data obtained at the National Energy Technology Laboratory. Complimentary to 'Computed Tomography Scanning and Geophysical Measurements of Core from the Coldstream 1MH Well" Technical Report Series, 2018

CT Scans↗

Tippens 6HS Well

Computed tomography scans and core log data obtained at the National Energy Technology Laboratory. Complimentary to 'CT Scanning and Geophysical Measurements of the Marcellus Formation from the Tippens 6HS Well" Technical Report Series, 2018

CT Scans↗

Herrick Well

Data generated at the National Energy Technology Laboratory, Morgantown WV from the Herrick 3HM well. API 34-111-2-4401-00-00 Lat/Long = 39.6572 N/80.9847W Monroe County, Ohio Core obtained by Eclipse Resources. Please see the following report for additional details: Brown, S.; Crandall, D.; Moore, J.; Mackey, P.; Carr, T.; Panetta, B. CT Scanning and Geophysical Measurements of the Utica Formation from the Herrick 3H Well; NETL-TRS-X-2018; NETL Technical Report Series; U.S. Department of Energy, National Energy Technology Laboratory: Morgantown, WV, 2018; p 94.

Computed Tomography↗

Using Unmanned Helicopters to Assess Vegetation Cover in Sagebrush Steppe Ecosystems

Evaluating vegetation cover is an important factor in understanding the sustainability of many ecosystems. Methods that have sufficient accuracy and improved cost efficiency could dramatically alter how biotic resources are monitored on both public and private lands. This will be of interest to land managers because there are rarely enough resource specialists or funds available for comprehensive ground evaluations. In this project, unmanned helicopters were used to collect still-frame imagery to assess vegetation cover during May, June, and July in 2005. The images were used to estimate percent cover for six vegetative cover classes (shrub, dead shrub, grass, forbs, litter, and bare ground). The field plots were located on the INL site west of Idaho Falls, Idaho. Ocular assessments of digital imagery were performed using a software program called SamplePoint, and the results were compared against field measurements collected using a point-frame method to assess accuracy. The helicopter imagery evaluation showed a high degree of agreement with field cover class values for litter, bare ground, and grass, and reasonable agreement for dead shrubs. Shrub cover was often overestimated and forbs were generally underestimated. The helicopter method took 45% less time than the field method to set plots and collect and analyze data. This study demonstrates that UAV technology provides a viable method for monitoring vegetative cover on rangelands in less time and with lower costs. Tradeoffs between cost and accuracy are critical management decisions that are important when managing vegetative conditions across vast sagebrush ecosystems throughout the Intermountain West.

54 ENVIRONMENTAL SCIENCES↗

Calcined Waste Storage at the Idaho Nuclear Technology and Engineering Center

This comprehensive report provides definitive volume, mass, and composition (chemical and radioactivity) of calcined waste stored at the Idaho Nuclear Technology and Engineering Center. Calcine composition data are required for regulatory compliance (such as permitting and waste disposal), future treatment of the caline, and shipping the calcine to an off-Site-facility (such as a geologic repository). This report also contains a description of the calcine storage bins. The Calcined Solids Storage Facilities (CSSFs) were designed by different architectural engineering firms and built at different times. Each CSSF has a unique design, reflecting varying design criteria and lessons learned from historical CSSF operation. The varying CSSF design will affect future calcine retrieval processes and equipment. Revision 4 of this report presents refinements and enhancements of calculations concerning the composition, volume, mass, chemical content, and radioactivity of calcined waste produced and stored within the CSSFs. The historical calcine samples are insufficient in number and scope of analysis to fully characterize the entire inventory of calcine in the CSSFs. Sample data exist for all the liquid wastes that were calcined. This report provides calcine composition data based on liquid waste sample analyses, volume of liquid waste calcined, calciner operating data, and CSSF operating data using several large Microsoft Excel (Microsoft 2003) databases and spreadsheets that are collectively called the Historical Processing Model. The calcine composition determined by this method compares favorably with historical calcine sample data.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Decision Insight into Stakeholder Conflict for ERN

Participatory modeling has become an important tool in facilitating resource decision making and dispute resolution. Approaches to modeling that are commonly used in this context often do not adequately account for important human factors. Current techniques provide insights into how certain human activities and variables affect resource outcomes; however, they do not directly simulate the complex variables that shape how, why, and under what conditions different human agents behave in ways that affect resources and human interactions related to them. Current approaches also do not adequately reveal how the effects of individual decisions scale up to have systemic level effects in complex resource systems. This lack of integration prevents the development of more robust models to support decision making and dispute resolution processes. Development of integrated tools is further hampered by the fact that collection of primary data for decision-making modeling is costly and time consuming. This project seeks to develop a new approach to resource modeling that incorporates both technical and behavioral modeling techniques into a single decision-making architecture. The modeling platform is enhanced by use of traditional and advanced processes and tools for expedited data capture. Specific objectives of the project are: (1) Develop a proof of concept for a new technical approach to resource modeling that combines the computational techniques of system dynamics and agent based modeling, (2) Develop an iterative, participatory modeling process supported with traditional and advance data capture techniques that may be utilized to facilitate decision making, dispute resolution, and collaborative learning processes, and (3) Examine potential applications of this technology and process. The development of this decision support architecture included both the engineering of the technology and the development of a participatory method to build and apply the technology. Stakeholder interaction with the model and associated data capture was facilitated through two very different modes of engagement, one a standard interface involving radio buttons, slider bars, graphs and plots, while the other utilized an immersive serious gaming interface. The decision support architecture developed through this project was piloted in the Middle Rio Grande Basin to examine how these tools might be utilized to promote enhanced understanding and decision-making in the context of complex water resource management issues. Potential applications of this architecture and its capacity to lead to enhanced understanding and decision-making was assessed through qualitative interviews with study participants who represented key stakeholders in the basin.

97 MATHEMATICS AND COMPUTING↗

Fuel Cell Backup Power Geographical Visualization Map (Fact Sheet)

This NREL Hydrogen and Fuel Cell Technical Highlight describes a time-lapse geographical visualization map of early market use of fuel cells for telecommunications backup power. The map synthesizes data being analyzed by NREL's Technology Validation team for the U.S. Department of Energy (DOE) Fuel Cell Technologies Program with DOE's publicly available annual summaries of electric disturbance events.

08 HYDROGEN↗

HIgh Rate X-ray Fluorescence Detector

The purpose of this project was to develop a compact, modular multi-channel x-ray detector with integrated electronics. This detector, based upon emerging silicon drift detector (SDD) technology, will be capable of high data rate operation superior to the current state of the art offered by high purity germanium (HPGe) detectors, without the need for liquid nitrogen. In addition, by integrating the processing electronics inside the detector housing, the detector performance will be much less affected by the typically noisy electrical environment of a synchrotron hutch, and will also be much more compact than current systems, which can include a detector involving a large LN2 dewar and multiple racks of electronics. The combined detector/processor system is designed to match or exceed the performance and features of currently available detector systems, at a lower cost and with more ease of use due to the small size of the detector. In addition, the detector system is designed to be modular, so a small system might just have one detector module, while a larger system can have many you can start with one detector module, and add more as needs grow and budget allows. The modular nature also serves to simplify repair.

47 OTHER INSTRUMENTATION↗

Data Release Report for Source Physics Experiments 2 and 3 (SPE-2 and SPE-3) Nevada National Security Site

The second Source Physics Experiment shot (SPE-2) was conducted in Nevada on October 25, 2011, at 1900:00.011623 Greenwich Mean Time (GMT). The explosive source was 997 kilograms (kg) trinitrotoluene (TNT) equivalent of sensitized heavy ammonium fuel oil (SHANFO) detonated at a depth of 45.7 meters (m). The third Source Physics Experiment shot (SPE-3) was conducted in Nevada on July 24, 2012, at 1800:00.44835 GMT. The explosive source was 905 kg TNT equivalent of SHANFO detonated at a depth of 45.8 m. Both shots were recorded by an extensive set of instrumentation that includes sensors both at near-field (less than 100 m) and far-field (100 m or greater) distances. The near-field instruments consisted of three-component accelerometers deployed in boreholes at 15, 46, and 55 m depths around the shot and a set of single-component vertical accelerometers on the surface. The far-field network was composed of a variety of seismic and acoustic sensors, including short-period geophones, broadband seismometers, three-component accelerometers, and rotational seismometers at distances of 100 m to 25 kilometers. This report coincides with the release of these data for analysts and organizations that are not participants in this program. This report describes the second and third Source Physics Experiment shots and the various types of near-field and far-field data that are available.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Balancing energy conservation and occupant needs in ventilation rate standards for Big Box stores and other commercial buildings in California. Issues related to the ASHRAE 62.1 Indoor Air Quality Procedure

This report considers the question of whether the California Energy Commission should incorporate the ASHRAE 62.1 ventilation standard into the Title 24 ventilation rate (VR) standards, thus allowing buildings to follow the Indoor Air Quality Procedure. This, in contrast to the current prescriptive standard, allows the option of using ventilation rate as one of several strategies, which might include source reduction and air cleaning, to meet specified targets of indoor air concentrations and occupant acceptability. The research findings reviewed in this report suggest that a revised approach to a ventilation standard for commercial buildings is necessary, because the current prescriptive ASHRAE 62.1 Ventilation Rate Procedure (VRP) apparently does not provide occupants with either sufficiently acceptable or sufficiently healthprotective air quality. One possible solution would be a dramatic increase in the minimum ventilation rates (VRs) prescribed by a VRP. This solution, however, is not feasible for at least three reasons: the current need to reduce energy use rather than increase it further, the problem of polluted outdoor air in many cities, and the apparent limited ability of increasing VRs to reduce all indoor airborne contaminants of concern (per Hodgson (2003)). Any feasible solution is thus likely to include methods of pollutant reduction other than increased outdoor air ventilation; e.g., source reduction or air cleaning. The alternative 62.1 Indoor Air Quality Procedure (IAQP) offers multiple possible benefits in this direction over the VRP, but seems too limited by insufficient specifications and inadequate available data to provide adequate protection for occupants. Ventilation system designers rarely choose to use it, finding it too arbitrary and requiring use of much non-engineering judgment and information that is not readily available. This report suggests strategies to revise the current ASHRAE IAQP to reduce its current limitations. These strategies, however, would make it more complex and more prescriptive, and would require substantial research. One practical intermediate strategy to save energy would be an alternate VRP, allowing VRs lower than currently prescribed, as long as indoor VOC concentrations were no higher than with VRs prescribed under the current VRP. This kind of hybrid, with source reduction and use of air cleaning optional but permitted, could eventually evolve, as data, materials, and air-cleaning technology allowed gradual lowering of allowable concentrations, into a fully developed IAQP. Ultimately, it seems that VR standards must evolve to resemble the IAQP, especially in California, where buildings must achieve zero net energy use within 20 years.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High Temperature Gas-Cooled Test Reactor Point Design: Summary Report

A point design has been developed for a 200-MW high-temperature gas-cooled test reactor. The point design concept uses standard prismatic blocks and 15.5% enriched uranium oxycarbide fuel. Reactor physics and thermal-hydraulics simulations have been performed to characterize the capabilities of the design. In addition to the technical data, overviews are provided on the technology readiness level, licensing approach, and costs of the test reactor point design.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

High Temperature Gas-Cooled Test Reactor Point Design: Summary Report

A point design has been developed for a 200-MW high-temperature gas-cooled test reactor. The point design concept uses standard prismatic blocks and 15.5% enriched uranium oxycarbide fuel. Reactor physics and thermal-hydraulics simulations have been performed to characterize the capabilities of the design. In addition to the technical data, overviews are provided on the technology readiness level, licensing approach, and costs of the test reactor point design.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Refine your search to explore more results.