Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TIME SIGNAL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

System for producing chroma signals

A method for obtaining electronic chroma signals with a single scanning-type image device is described. A color multiplexed light signal is produced using an arrangement of dichroic filter stripes. In the particular system described, a two layer filter is used to color modulate external light which is then detected by an image pickup tube. The resulting time division multiplexed electronic signal from the pickup tube is converted by a decoder into a green color signal, and a single red-blue multiplexed signal, which is demultiplexed to produce red and blue color signals. The three primary color signals can be encoded as standard NTSC color signals.

Vorhaben, K. H.↗

A study of aluminum-lithium alloy solidification using acoustic emission techniques

Physical phenomena associated with the solidification of an aluminum lithium alloy was characterized using acoustic emission (AE) techniques. It is shown that repeatable patterns of AE activity may be correlated to microstructural changes that occur during solidification. The influence of the experimental system on generated signals was examined in the time and frequency domains. The analysis was used to show how an AE signal from solidifying aluminum is changed by each component in the detection system to produce a complex waveform. Conventional AE analysis has shown that a period of high AE activity occurs in pure aluminum, an Al-Cu alloy, and the Al-Li alloy, as the last fraction of solid forms. A model attributes this to the internal stresses of grain boundary formation. An additional period of activity occurs as the last fraction of solid forms, but only in the two alloys. A model attributes this to the formation of interdendritic porosity which was not present in the pure aluminum. The AE waveforms were dominated by resonant effects of the waveguide and the transducer.

Henkel, Daniel P.↗

Mars 2020 Entry, Descent, and Landing as Observed by Radio Science Techniques at UHF and X-band Frequencies

On February 18, 2021, NASA’s Mars 2020 Rover “Perseverance” conducted the Entry, Descent, and Landing (EDL) sequence to land safely on the surface of Mars at Jezero Crater. Due to the criticality of the EDL sequence, redundant telecommunications strategies were utilized to observe the event. The rover transmitted an X-band (8.4 GHz) signal encoded with Multiple Frequency Shift Keying tones direct-to-Earth and a UHF (401.5 MHz) signal with 8 kbps encoded telemetry to orbiters, which relayed the signal back to Earth at X-band. NASA’s Deep Space Network complexes at Goldstone, California and Madrid, Spain received the direct-to-Earth X-band signal. Two of the largest steerable radio telescopes in the world, the 100-meter Green Bank Telescope in West Virginia and the Effelsberg 100-meter Radio Telescope in Germany also received the UHF carrier signal on Earth. During the EDL event, full spectrum recordings of the UHF and X-band signals were captured at these observatories using open-loop receivers. Real-time and post-processing signal analysis to determine power level, received frequency, and Doppler shift allowed determination of the spacecraft’s health and safety state during critical sequences, including event detection such as atmospheric entry, plasma blackouts, and parachute deployment. Simultaneous observations of the UHF and X-band radio links allow for redundancy in the event of a fault and greatly improve confidence in Doppler event detection.

Gladden, Roy↗

RHESSI TESTS OF QUASI-THERMAL GAMMA-RAY BURST SPECTRAL MODELS

Prompt gamma-ray burst (GRB) spectra evolve on short timescales, suggesting that time-resolved spectral fits may help diagnose the still unknown prompt emission mechanism. We use broadband gamma-ray data from the Ramaty High-Energy Solar Spectroscopic Imager spacecraft to test quasi-thermal models with high signal-to-noise time-resolved spectra of nine bright GRBs. In contrast to results reported in more narrow energy bands, the quality of the fits of quasi-thermal models is poor in relation to fits of the phenomenological Band function. Moreover, the best-fit parameters for the simplest quasi-thermal model, a blackbody plus a nonthermal power law, show significant dependence on the fit band. Models that replace the power law with more complicated nonthermal functions are not robust for the data considered here and decrease the physical relevance of the fit blackbody.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time Distribution Using SpaceWire in the SCaN Testbed on ISS

A paper describes an approach for timekeeping and time transfer among the devices on the CoNNeCT project s SCaN Testbed. It also describes how the clocks may be synchronized with an external time reference; e.g., time tags from the International Space Station (ISS) or RF signals received by a radio (TDRSS time service or GPS). All the units have some sort of counter that is fed by an oscillator at some convenient frequency. The basic problem in timekeeping is relating the counter value to some external time standard such as UTC. With SpaceWire, there are two approaches possible: one is to just use SpaceWire to send a message, and use an external wire for the sync signal. This is much the same as with the RS- 232 messages and l pps line from a GPS receiver. However, SpaceWire has an additional capability that was added to make it easier - it can insert and receive a special "timecode" word in the data stream.

Lux, James P.↗

X-Ray Detection and Processing Models for Spacecraft Navigation and Timing

The current primary method of deepspace navigation is the NASA Deep Space Network (DSN). High-performance navigation is achieved using Delta Differential One-Way Range techniques that utilize simultaneous observations from multiple DSN sites, and incorporate observations of quasars near the line-of-sight to a spacecraft in order to improve the range and angle measurement accuracies. Over the past four decades, x-ray astronomers have identified a number of xray pulsars with pulsed emissions having stabilities comparable to atomic clocks. The x-ray pulsar-based navigation and time determination (XNAV) system uses phase measurements from these sources to establish autonomously the position of the detector, and thus the spacecraft, relative to a known reference frame, much as the Global Positioning System (GPS) uses phase measurements from radio signals from several satellites to establish the position of the user relative to an Earth-centered fixed frame of reference. While a GPS receiver uses an antenna to detect the radio signals, XNAV uses a detector array to capture the individual xray photons from the x-ray pulsars. The navigation solution relies on detailed xray source models, signal processing, navigation and timing algorithms, and analytical tools that form the basis of an autonomous XNAV system. Through previous XNAV development efforts, some techniques have been established to utilize a pulsar pulse time-of-arrival (TOA) measurement to correct a position estimate. One well-studied approach, based upon Kalman filter methods, optimally adjusts a dynamic orbit propagation solution based upon the offset in measured and predicted pulse TOA. In this delta position estimator scheme, previously estimated values of spacecraft position and velocity are utilized from an onboard orbit propagator. Using these estimated values, the detected arrival times at the spacecraft of pulses from a pulsar are compared to the predicted arrival times defined by the pulsar s pulse timing model. A discrepancy provides an estimate of the spacecraft position offset, since an error in position will relate to the measured time offset of a pulse along the line of sight to the pulsar. XNAV researchers have been developing additional enhanced approaches to process the photon TOAs to arrive at an estimate of spacecraft position, including those using maximum-likelihood estimation, digital phase locked loops, and "single photon processing" schemes that utilize all available time data associated with each photon. Using pulsars from separate, non-coplanar locations provides range and range-rate measurements in each pulsar s direction. Combining these different pulsar measurements solves for offsets in position and velocity in three dimensions, and provides accurate overall navigation for deep space vehicles.

Sheikh, Suneel↗

Radial profile measurements of plasma pressure-like fluctuations with the heavy ion beam diagnostic on the tokamak ISTTOK

The Heavy Ion Beam Diagnostic (HIBD) on the tokamak ISTTOK (Instituto Superior Técnico TOKamak) has been modified, in terms of signal conditioning, to measure the local fluctuations of the n{sub e}σ{sub 1,2}(T{sub e}) product (plasma density times the effective ionization cross-section) along the tokamak minor diameter, in 12 sample volumes in the range of −0.7a < r < 0.7a, with a maximum delay time of 1 μs. The corresponding signals show high correlation with the magnetic Mirnov coils in the characteristic MHD frequency range of ISTTOK plasmas and enable the identification of tearing modes. This paper describes the HIBD signal conditioning system and presents a preliminary analysis of the radial profile measurements of local n{sub e}σ{sub 1,2}(T{sub e}) fluctuations.

43 PARTICLE ACCELERATORS↗

Intracavity laser spectroscopy by using a Fe{sup 2+}:ZnSe laser

A Fe{sup 2+}:ZnSe laser emitting in the spectral range between 3.77 and 5.05 {mu}m is used for the first time for intracavity laser spectroscopy. The intracavity absorption spectra of methane in the 4.1-{mu}m region are recorded at different instants of lasing (0-80 {mu}s) and the dynamics of spectral holes during lasing is investigated. It is found that an intracavity absorption signal linearly increases with time during lasing in the time range from 0 to 80 {mu}s, which provides the effective absorption length up to 24 km. (laser spectroscopy)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

WE-FG-206-05: New Arterial Spin Labeling Method for Simultaneous Estimation of Arterial Cerebral Blood Volume, Cerebral Blood Flow and Arterial Transit Time

Purpose: To demonstrate the feasibility of a novel Arterial Spin Labeling (ASL) method for simultaneously measuring cerebral blood flow (CBF), arterial transit time (ATT), and arterial cerebral blood volume (aCBV) without the use of a contrast agent. Methods: A series of multi-TI ASL images were acquired from one healthy subject on a 3T Siemens Skyra, with the following parameters: PCASL labeling with variable TI [300, 400, 500, 600, 700, 800, 900, 1000, 1500, 2000, 2500, 3000, 3500, 4000] ms, labeling bolus 1400 ms when TI allows, otherwise 100 ms less than TI, TR was minimized for each TI, two sinc shaped pre-saturation pulses were applied in the imaging plane immediately before 2D EPI acquisition. 64×64×24 voxels, 5 mm slice thickness, 1 mm gap, full brain coverage, 6 averages per TI, no crusher gradients, 11 ms TE, scan time of 4:56. The perfusion weighted time-series was created for each voxel and fit to a novel model. The model has two components: 1) the traditional model developed by Buxton et al., accounting for CBF and ATT, and 2) a box car function characterizing the width of the labeling bolus, with variable timing and height in proportion to the aCBV. All three parameters were fit using a nonlinear fitting routine that constrained all parameters to be positive. The main purpose of the high-temporal resolution TI sampling for the first second of data acquisition was to precisely estimate the blood volume component for better detection of arrival time and magnitude of signal. Results: Whole brain maps of CBF, ATT, and aCBV were produced, and all three parameters maps are consistent with similar maps described in the literature. Conclusion: Simultaneous mapping of CBF, ATT, and aCBV is feasible with a clinically tractable scan time (under 5 minutes).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A decision model applied to alcohol effects on driver signal light behavior

A decision model including perceptual noise or inconsistency is developed from expected value theory to explain driver stop and go decisions at signaled intersections. The model is applied to behavior in a car simulation and instrumented vehicle. Objective and subjective changes in driver decision making were measured with changes in blood alcohol concentration (BAC). Treatment levels averaged 0.00, 0.10 and 0.14 BAC for a total of 26 male subjects. Data were taken for drivers approaching signal lights at three timing configurations. The correlation between model predictions and behavior was highly significant. In contrast to previous research, analysis indicates that increased BAC results in increased perceptual inconsistency, which is the primary cause of increased risk taking at low probability of success signal lights.

Schwartz, S. H.↗

Respiratory modulation of human autonomic rhythms

We studied the influence of three types of breathing [spontaneous, frequency controlled (0.25 Hz), and hyperventilation with 100% oxygen] and apnea on R-R interval, photoplethysmographic arterial pressure, and muscle sympathetic rhythms in nine healthy young adults. We integrated fast Fourier transform power spectra over low (0.05-0.15 Hz) and respiratory (0.15-0.3 Hz) frequencies; estimated vagal baroreceptor-cardiac reflex gain at low frequencies with cross-spectral techniques; and used partial coherence analysis to remove the influence of breathing from the R-R interval, systolic pressure, and muscle sympathetic nerve spectra. Coherence among signals varied as functions of both frequency and time. Partialization abolished the coherence among these signals at respiratory but not at low frequencies. The mode of breathing did not influence low-frequency oscillations, and they persisted during apnea. Our study documents the independence of low-frequency rhythms from respiratory activity and suggests that the close correlations that may exist among arterial pressures, R-R intervals, and muscle sympathetic nerve activity at respiratory frequencies result from the influence of respiration on these measures rather than from arterial baroreflex physiology. Most importantly, our results indicate that correlations among autonomic and hemodynamic rhythms vary over time and frequency, and, thus, are facultative rather than fixed.

Non-NASA Center↗

Detection of Ocean Reflected GPS Signals: Theory and Experiment

A number of advanced applications of the Global Positioning System (GPS) have been proposed which use the signal reflected from a smooth ocean surface. The viability of these concepts hinges upon the ability to acquire and code track the reflected signal for an extended period of time over a variety of sea states. The analytical theory of specularly and diffusely reflected radio frequency radiation from a rough surface is reviewed. Experiments to demonstrate tracking of a reflected signal were performed on three aircraft flights over the Chesapeake Bay and the Eastern Shore of Virginia. The experimental hardware consisted of two of-the-shelf receivers configured so that one received the GPS signal in the conventional manner using a right hand circularly polarized (RHCP) antenna on top of the fuselage and the other could receive the reflected signal using a left hand circularly polarized (LHCP) antenna on the bottom of the fuselage. Three tests were performed on the data to verify that the signals received in the bottom antenna were viewed as sea surface reflections; Pseudorange double differences were compared against predicted geometric range double differences; Characteristics of a signal reflected from a random surface were observed in the carrier to noise ratio; Predicted specular points were plotted which demonstrate reflection only from wet areas. These tests indicated tracking of reflected signals for extended periods of time at altitudes of up to 5500 m and sporadic signal acquisition at higher altitudes. The duration of the continuous signal tracking was limited by the receiver's need to maintain carrier tracking.

Garrison, James L.↗

A novel approach for identifying the true temperature sensitivity from soil respiration measurements

We propose a novel approach, called the localized ratio fitting (LRF), to estimating the true temperature sensitivity from soil respiration measurements, a task crucial to modeling terrestrial carbon cycle and climate but so far hindered by the inadequate conventional regression approach. LRF takes advantage of the different timescales of the pool dynamics Cinduced and environmental variation Cinduced changes in soil CO2 efflux. It first transforms the expression for soil respiration into a form suppressing the influence of soil carbon pool dynamics and then uses the transformed expression to infer the parameters of environmental sensitivities. LRF works best for high-frequency soil respiration measurements and thus is particularly suitable for analyzing time series produced by automated soil chambers and from soil incubation experiments. We evaluated the validity of LRF with both simulated (with a multipool soil organic carbon model driven by realistic plant litter input scenarios) and measured (with automated soil chambers) time series of soil respiration. LRF accurately retrieved the true temperature sensitivity from the simulated heterotrophic soil respiration while the conventional approach failed to do so. The simulation also revealed that LRF performed better than the conventional approach when a direct photosynthetic signal existed in the time series of soil respiration although even LRF could not completely eliminate the interference of photosynthetic contribution for estimating the true temperature sensitivity. Importantly, the simulation on the photosynthetic influence reproduced a typical seasonal pattern of apparent temperature sensitivity reported in the literature: higher sensitivity in winter (dormant season) and lower sensitivity in summer (growing season). Such pattern has been interpreted as an indication of temperature acclimation of soil respiration by previous studies. Our simulation now indicated that that interpretation may be incorrect. The validation with actual soil chamber data showed that the use of LRF led to more consistent estimates of temperature and moisture sensitivities from observations, indicating its better robustness against compounding effects of parallel processes on soil respiration. It was demonstrated that once the true environmental controls were properly accounted for, soil respiration measurements could be used to infer effects of biological processes on soil respiration.

54 ENVIRONMENTAL SCIENCES↗

Imaging of transition charge densities involving carbon core excitations by all X-ray sum-frequency generation

X-ray diffraction signals from the time-evolving molecular charge density induced by selective core excitation of chemically inequivalent carbon atoms are calculated. A narrowband X-ray pulse selectively excites the carbon K-edge of the –CH 3 or –CH 2 F groups in fluoroethane (CH 3 –CH 2 F). Each excitation creates a distinct core coherence which depends on the character of the electronic transition. Direct propagation of the reduced single-electron density matrix, using real-time time-dependent density functional theory, provides the time-evolving charge density following interactions with external fields. Here, the interplay between partially filled valence molecular orbitals upon core excitation induces characteristic femtosecond charge migration which depends on the core–valence coherence, and is monitored by the sum-frequency generation diffraction signal.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Graphene metamaterial modulator for free-space thermal radiation

We proposed and demonstrated a new metamaterial architecture capable of high speed modulation of free-space space thermal infrared radiation using graphene. Our design completely eliminates channel resistance, thereby maximizing the electrostatic modulation speed, while at the same time effectively modulating infrared radiation. Experiment results verify that our device with area of 100 × 120 µm 2 can achieve a modulation speed as high as 2.6 GHz. We further highlight the utility of our graphene metamaterial modulator by reconstructing a fast infrared signal using an equivalent time sampling technique. The graphene metamaterial modulator demonstrated here is not only limited to the thermal infrared, but may be scaled to longer infrared and terahertz wavelengths. Our work provides a path forward for realization of frequency selective and all-electronic high speed devices for infrared applications.

36 MATERIALS SCIENCE↗

Robust low-frequency spread-spectrum navigation system

Methods and apparatus are described for a navigation system. A process includes providing a plurality of transmitters distributed throughout a desired coverage area; locking the plurality of transmitters to a common timing reference; transmitting a signal from each of the plurality of transmitters. An apparatus includes a plurality of transmitters distributed throughout a desired coverage area; wherein each of the plurality of transmitters comprises a packet generator; and wherein the plurality of transmitters are locked to a common timing reference.

47 OTHER INSTRUMENTATION↗

Refine your search to explore more results.