Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Simulation Software”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Coupled Electro-Thermal Analysis of Permanent Magnet Synchronous Motor for Electric Vehicles

Permanent magnet synchronous motors (PMSM) are extensively used in electric vehicles. However, high internal heat generation and inefficient heat dissipation often limit the operational reliability, and longevity of the PMSM. Therefore, proper quantification of heat generation in electric motor and advanced embedded motor cooling techniques remain topics of immense interest. In order to accurately predict electro-magnetic performance, i.e., efficiency, component-wise heat losses and the corresponding temperature distribution of a jacket cooled machine, this paper presents a two-way iteratively coupled electro-thermal modeling framework. Finite element based software Motor-CAD has been utilized for electro-magnetic performance calculation of BMW i3 PMSM. Finite volume based computational fluid dynamics/heat transfer (CFD/HT) software ANSYS® FLUENT® has been employed to simulate the temperature distribution of the PMSM, using the electro-magnetic losses as heat input. Computed heat losses, stator, winding, rotor, and magnet temperatures are utilized as coupling parameters between the electro-magnetic and thermal models. A conventional one-way coupling algorithm has also been developed and compared to the newly proposed two-way coupling algorithm. Numerical results confirm that at high current density, one-way coupling algorithm significantly over-predicts the motor temperature compared to the two-way algorithm. A comprehensive analysis has been carried out to characterize the influences of current density, speed, and forced convection heat transfer coefficient on the heat losses, overall efficiency, and maximum temperature of the PMSM. Lastly, an efficiency map has been interpreted from the coupled electro-magnetic simulation.

42 ENGINEERING↗

A domain-specific compiler for a parallel multiresolution adaptive numerical simulation environment

This paper describes the design and implementation of a layered domain-specific compiler to support MADNESS---Multiresolution ADaptive Numerical Environment for Scientific Simulation. MADNESS is a high-level software environment for the solution of integral and differential equations in many dimensions, using adaptive and fast harmonic analysis methods with guaranteed precision. MADNESS uses k-d trees to represent spatial functions and implements operators like addition, multiplication, differentiation, and integration on the numerical representation of functions. The MADNESS runtime system provides global namespace support and a task-based execution model including futures. MADNESS is currently deployed on massively parallel supercomputers and has enabled many science advances. Due to the highly irregular and statically unpredictable structure of the k-d trees representing the spatial functions encountered in MADNESS applications, only purely runtime approaches to optimization have previously been implemented in the MADNESS framework. This paper describes a layered domain-specific compiler developed to address some performance bottlenecks in MADNESS. The newly developed static compile-time optimizations, in conjunction with the MADNESS runtime support, enable significant performance improvement for the MADNESS framework.

Rajbhandari, Samyam↗

Full-System Linearization for Floating Offshore Wind Turbines in OpenFAST

The wind engineering community relies on multiphysics engineering software to run nonlinear time-domain simulations (e.g., for design-standards-based loads analysis). Although most physics involved in wind energy are nonlinear, linearization of the underlying nonlinear system equations is often advantageous to understand the system properties and exploit well-established methods and tools for analyzing linear systems. This paper presents the development of the new linearization functionality of the open-source engineering tool OpenFAST for floating offshore wind turbines, as well as the concepts and mathematical background needed to understand and apply it.

17 WIND ENERGY↗

Effects of breathing variation on gating window internal target volume in respiratory gated radiation therapy

Purpose: To investigate the effects of breathing variation on gating window internal target volume (ITV{sub GW}) in respiratory gated radiation therapy. Method and Materials: Two-dimensional dynamic MRI (dMRI) of lung motion was acquired in ten volunteers and eight lung cancer patients. Resorted dMRI using 4DCT acquisition method (RedCAM) was generated for selected subjects by simulating the image rebinning process. A dynamic software generated phantom (dSGP) was created by moving a solid circle (to mimic the ''tumor'') with dMRI-determined motion trajectories. The gating window internal target area (ITA{sub GW}, 2D counterpart of ITV{sub GW}) was determined from both RedCAM and dSGP/dMRI. Its area (A), major axis (L1), minor axis (L2), and similarity (S) were calculated and compared. Results: In the phantom study of 3 cm tumor, measurements of the ITA{sub GW} from dSGP (A=10.0{+-}1.3 cm{sup 2}, L1=3.8{+-}0.4 cm, and L2=3.3{+-}0.1 cm) are significantly (p<0.001) greater than those from RedCAM (A=8.5{+-}0.7 cm{sup 2}, L1=3.5{+-}0.2 cm, and L2=3.1{+-}0.1 cm). Similarly, the differences are significantly greater (p<0.001) for the 1 cm tumor (A=1.9{+-}0.5 cm{sup 2}, L1=1.9{+-}0.4 cm, and L2=1.3{+-}0.1 cm in dSGP; A=1.3{+-}0.1 cm{sup 2}, L1=1.5{+-}0.2 cm, and L2=1.1{+-}0.1 cm in RedCAM). In patient studies, measurements of the ITA{sub GW} from dMRI (A=15.5{+-}8.2 cm{sup 2}, L1=5.0{+-}1.1 cm, and L2=3.8{+-}1.2 cm) are also significantly greater (p<0.05) than those from RedCAM (A=13.2{+-}8.5 cm{sup 2}, L1=4.3{+-}1.4 cm, and L2=3.7{+-}1.2 cm). Similarities were 0.9{+-}0.1, 0.8{+-}0.1, and 0.8{+-}0.1 in the 3 cm tumor phantom, 1 cm tumor phantom, and patient studies, respectively. Conclusion: ITV{sub GW} can be underestimated by 4DCT due to breathing variations. An additional margin may be needed to account for this potential error in generating a PTV{sub GW}. Cautions need to be taken when generating ITV{sub GW} from 4DCT in respiratory gated radiation therapy, especially for small tumors (<3 cm) with a large motion range (>1 cm).

60 APPLIED LIFE SCIENCES↗

TU-F-CAMPUS-I-01: Investigation of the Effective Dose From Bolus Tracking Acquisitions at Different Anatomical Locations in the Chest for CT

Purpose: Stationary table acquisitions (Bolus tracking) in X-ray Computed Tomography (CT) can Result in dose length products (DLP) comparable to spiral scans. It is today unclear whether or not the effective dose (E) for Bolus Tracking can be approximated using target region specific conversion factors (E/DLP). The purpose of this study was to investigate how E depends on the anatomical location of the Bolus Tracking in relation to Chest CT scans with the same DLP. Methods: Effective doses were approximated for the ICRP 110 adult Reference Male (AM) and adult Reference Female (FM) computational voxel phantoms using software for CT dose approximations (pre-simulated MC data). The effective dose was first approximated for a Chest CT scan using spiral technique and a CTDIvol (32 cm) of 6 mGy. The effective dose from the spiral scan was then compared to E approximated for contiguous Bolus Tracking acquisitions (1 cm separation), with a total collimation of 1 cm, over different locations of the chest of the voxel phantoms. The number of rotations used for the Bolus Tracking acquisitions was adjusted to yield the same DLP (32 cm) as the spiral scan. Results: Depending on the anatomical location of the Bolus Tracking, E ranged by factors of 1.3 to 6.8 for the AM phantom and 1.4 to 3.3 for the AF phantom, compared to the effective dose of the spiral scans. The greatest E for the Bolus Tracking acquisitions was observed for anatomical locations coinciding with breast tissue. This can be expected as breast tissue has a high tissue weighting factor in the calculation of E. Conclusion: For Chest CT scans, the effective dose from Bolus Tracking is highly dependent on the anatomical location where the scan is administered and will not always accurately be represented using target region specific conversion factors.

60 APPLIED LIFE SCIENCES↗

SU-F-I-27: Measurement of SAR and Temperature Elevation During MRI Scans

Purpose: The poor reliability and repeatability of the manufacturer-reported SAR values on clinical MRI systems have been acknowledged. The purpose of this study is to not only measure SAR values, but also RF-induced temperature elevation at 1.5 and 3T MRI systems. Methods: SAR measurement experiment was performed at 1.5 and 3T. Three MRI RF sequences (T1w TSE, T1w inversion recovery, and T2w TSE) with imaging parameters were selected. A hydroxyl-ethylcelluose (HEC) gelled saline phantom mimicking human body tissue was made. Human torso phantom were constructed, based on Korean adult standard anthropometric reference data (Fig.1). FDTD method was utilized to calculate the SAR distribution using Sim4Life software. Based on the results of the simulation, 4 electrical field (E-field) sensors were located inside the phantom. 55 Fiber Bragg Grating (FBG) temperature sensors (27 sensors in upper and lower cover lids, and one sensor located in the center as a reference) were located inside the phantom to measure temperature change during MRI scan (Fig.2). Results: Simulation shows that SAR value is 0.4 W/kg in the periphery and 0.001 W/kg in the center (Fig.2). One 1.5T and one of two 3T MRI systems represent that the measured SAR values were lower than MRI scanner-reported SAR values. However, the other 3T MRI scanner shows that the averaged SAR values measured by probe 2, 3, and 4 are 6.83, 7.59, and 6.01 W/kg, compared to MRI scanner-reported whole body SAR value (<1.5 W/kg) for T2w TSE (Table 1). The temperature elevation measured by FBG sensors is 5.2°C in the lateral shoulder, 5.1°C in the underarm, 4.7°C in the anterior axilla, 4.8°C in the posterior axilla, and 4.8°C in the lateral waist for T2w TSE (Fig.3). Conclusion: It is essential to assess the safety of MRI system for patient by measuring accurate SAR deposited in the body during clinical MRI.

60 APPLIED LIFE SCIENCES↗

MO-FG-CAMPUS-IeP3-01: Evaluation of Specific Absorption Rate and Temperature Increase Induced by Artificial Medical Implants During MRI Scan

Purpose: Heating of patients or burning of biological tissues around medical implants by RF power during MRI scan is a significant patient safety concern. The purpose of this study is to not only measure SAR values, but also RF-induced temperature elevation due to artificial hip joints during MRI scans. Methods: SAR measurement experiment was performed on three discrete manufacturers at 1.5 and 3T. Three MRI RF sequences (T1w TSE, T2w inversion recovery, and T2w TSE) with imaging parameters were selected. A gelled saline phantom mimicking human body tissue was made (Fig.1). FDTD method was utilized to calculate the SAR distribution using Sim4Life software. Based on the results of the simulation, 4 electrical field (E-field) sensors were located around two artificial hip joints inside the phantom. 56 Fiber Bragg Grating (FBG) temperature sensors (28 sensors on each artificial hip joint) were located on both left and right artificial hip joints to measure temperature change during MRI scan (Fig.1). Both E-field and FBG temperature sensors were calibrated with traceability at Korea Research Institute of Standards and Science (KRISS). Results: Simulation shows that high SAR values occur in the head and tail of the implanted artificial hip joints (Fig.1 lower right). 3T MRI scanner shows that the local averaged-SAR values measured by probe 1, 2, and 3 are 2.30, 2.77, and 1.68 W/kg, compared to MRI scanner-reported whole body SAR value (≤1.5 W/kg) for T1w TSE and T2w-IR (Table 1). The maximum temperature elevation measured by FBG sensors is 1.49°C at 1.5 T, 2.0°C at 3 T, and 2.56°C at 3 T for T1w TSE, respectively (Table 2). Conclusion: It is essential to assess the safety of MRI system for patient with medical implant by measuring not only accurate SAR deposited in the body, but also temperature elevation due to the deposited SAR during clinical MRI.

60 APPLIED LIFE SCIENCES↗

CryoModule On Chip (CMOC) v1.0

The software, titled Cryomodule-On-Chip (CMOC), simulates a cryomodule used for low-level RF acceleration in superconducting cavities. The model includes a state-space model of the accelerating fields inside the cavity, the mechanical resonances inside a cryomodule, and their interactions.

Pareja, CarlosSerrano↗

HPCGraph v. 0.1

Graphs occur in several places in real world from road networks, social networks and scientific simulations. HPC Graph is a graph analysis software to analyze the properties such as connectivity, communities etc in extreme scale graphs.

Slota, George↗

Learning Planar Ising Models Software

Learning Planar Ising Models is a software package written in Matlab for learning relationships among variable in a dataset using graphical models. The software package implements a generally-applicable algorithm for learning planar Ising models from any multivariate dataset. The code provides an algorithm for learning the best planar Ising model to approximate an arbitrary collection of binary random variables (possibly from sample data). Given the set of all pairwise correlations among variables, we select a planar graph and optimal planar Ising model defined on this graph to best approximate that set of correlations. The software includes demonstrations of the algorithm in simulations and for applications on publicly available datasets. Details of the algorithm, demonstration simulations, and applications are given in Johnson, et al; 2016. Reference: Johnson, J. K., Oyen, D., Chertkov, M., and Netrapalli, P. (2016). Learning planar Ising models. Journal of Machine Learning Research.

Oyen, Diane↗

Flash-X

Flash-X is a highly composable multiphysics software system that can be used to simulate physical phenomena in several scientific domains. It is derived from FLASH, which has been a community code for several communities over the last 20 years. The Flash-X architecture has been redesigned to be compatible with increasingly heterogeneous hardware platforms. A part of the redesign is a utilizing a newly designed performance portability layer that is language agnostic.

Dubey, Anshu [Argonne National Laboratory (ANL), A↗

Code for Experiment in Publication “Sensitivity Analysis in the Presence of Intrinsic Stochasticity for Discrete Fracture Network Simulations”

Following the Open Research requirements for AGU journals, we must release the code used to perform the experiment described in our recent publication, posted at (https://arxiv.org/abs/2312.04722). This code fits a joint emulator to data from a Discrete Fracture Network (DFN) simulation, performed using the open-source software DFNworks (https://dfnworks.lanl.gov/). All code to be released implements existing methods; there are no novel algorithms nor any major innovations to existing software.

Murph, Alexander↗

Code for Experiment in Publication “Determining the dominant factors for carbon-1 mineralization in three-dimensional fracture networks”

We plan to release the code used to perform the experiment described in our recent publication, entitled “Determining the dominant factors for carbon-1 mineralization in three-dimensional fracture networks.” This code fits a joint emulator to data from several Discrete Fracture Network (DFN) simulations, performed using the open-source software DFNworks (https://dfnworks.lanl.gov/). All code to be released implements existing methods; there are no novel algorithms nor any major innovations to existing software.

Murph, Alexander↗

Flexible Resource Scheduler for FAST-DERMS (FRS-FASTDERMS) v0.9

The Flexible Resource Scheduler is a hierarchical controller that manages the distributed energy resources in a distribution substation or distribution feeder to provide a firm commitment of power flow at the substation or feeder head to be scheduled in transmission-level markets as an aggregated demand resource. It is the reference controller for the FAST-DERMS Architecture, developed in tandem with the architecture under the DOE FAST-DERMS project. It is comprised of a day-ahead stochastic optimization, which schedules substation power flow and reserves, a intra-hour MPC, which generates dispatch base points for DER, and a real-time PID controller maintaining that dispatches DER to maintain the substation power around the base points. The repository also includes a representative aggregator controller, and all of the necessary components to run a simulation using PNNL's GridAPPS-D software with the controller.

MacDonald, Jason [Lawrence Berkeley National Labor↗

Simulate_PCR for amplicon prediction and annotation from multiplex, degenerate primers and probes

Background: Pairing up primers to amplify desired targets and avoid undesired cross reactions can be a combinatorial challenge. Effective prediction of specificity and inclusivity from multiplexed primers and TaqMan®/ Luminex® probes is a critical step in PCR design. Results: Code is described to identify all primer and probe combinations from a list of unpaired, unordered candidates that should produce a product. It predicts and extracts all amplicon sequences in a large sequence database from a list of primers and probes, allowing degenerate bases and user-specified levels of primer-target mismatch tolerance. Amplicons hit by TaqMan®/Luminex® probes are indicated, and products may be annotated with gene information from NCBI. Fragment length distributions are calculated to predict electrophoretic gel banding patterns. Conclusions: Simulate_PCR is the only freely available software that can be run from the command line for high throughput applications which can calculate all products from large lists of primers and probes compared to a large sequence database such as nt. It requires no prior knowledge of how primers should be paired. Degenerate bases are allowed and entire amplicon sequences are extracted and annotated with gene information. Examples are provided for sets of TaqMan®/Luminex® PCR signatures predicted to amplify all HIV-1 genomes, all Coronaviridae genomes, and a group of antibiotic resistance genes. The software is a command line perl script freely available as open source.

59 BASIC BIOLOGICAL SCIENCES↗

Development of a high-fidelity multi-cycle model of the NuScale small modular reactor using VERA

With growing renewables penetration, there is increased interest in flexible power operation for nuclear reactors. For multi-unit SMRs, in particular the NuScale SMR, which is an integral pressurized water reactor, there are opportunities to optimize flexible power operation across multiple units to limit the degradation of structural and control components. Here, we focus on degradation of in-core components, specifically the control rods and reactor pressure vessel. To perform these studies a high-fidelity, multi-cycle representation of the NuScale SMR is required, with a detailed representation of the structural and control components. To this end, the NuScale SMR has been modelled using the Virtual Environment for Reactor Applications (VERA) software. The entire transition to equilibrium is simulated, from Cycle 1 through to the equilibrium cycle. The equilibrium cycle model shows a good agreement with the NuScale design certification application (DCA) results, with differences attributable to a combination of using public domain data for the present study, and methodological differences. K-effective, power distributions, reactivity coefficients, and boron letdown curves are compared and all found to closely match. This shows that the VERA model is suitable for further studies. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Ultrahigh energy resolution focusing monochromator for inelastic x-ray scattering spectrometer

A further development of a focusing monochromator concept for X-ray energy resolution of 0.1 meV and below is presented. Theoretical analysis of several optical layouts based on this concept was supported by numerical simulations performed in the “Synchrotron Radiation Workshop” software package using the physical-optics approach and careful modeling of partially-coherent synchrotron (undulator) radiation. Along with the energy resolution, the spectral shape of the energy resolution function was investigated. It was shown that under certain conditions the decay of the resolution function tails can be faster than that of the Gaussian function.

36 MATERIALS SCIENCE↗

A theory manual for multi-physics code coupling in LIME.

The Lightweight Integrating Multi-physics Environment (LIME) is a software package for creating multi-physics simulation codes. Its primary application space is when computer codes are currently available to solve different parts of a multi-physics problem and now need to be coupled with other such codes. In this report we define a common domain language for discussing multi-physics coupling and describe the basic theory associated with multiphysics coupling algorithms that are to be supported in LIME. We provide an assessment of coupling techniques for both steady-state and time dependent coupled systems. Example couplings are also demonstrated.

99 GENERAL AND MISCELLANEOUS↗

Refine your search to explore more results.