Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Signal Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

System and method for generating micro-seismic events and characterizing properties of a medium with non-linear acoustic interactions

A method and system includes generating a first coded acoustic signal including pulses each having a modulated signal at a central frequency; and a second coded acoustic signal each pulse of which includes a modulated signal a central frequency of which is a fraction d of the central frequency of the modulated signal for the corresponding pulse in the first plurality of pulses. A receiver detects a third signal generated by a non-linear mixing process in the mixing zone and the signal is processed to extract the third signal to obtain an emulated micro-seismic event signal occurring at the mixing zone; and to characterize properties of the medium or creating a 3D image of the properties of the medium, or both, based on the emulated micro-seismic event signal.

58 GEOSCIENCES↗

Characterization of Hamamatsu VUV4 SiPM Performance for Liquid Argon Scintillation

Detection of light signals is crucial to a wide range of particle detectors. In particular, efficient detection of vacuum ultraviolet (VUV) light will provide new opportunities for some novel detectors currently being developed, but is technically challenging. In this article, we characterized the performance of Hamamatsu VUV4 silicon photomultipliers (SiPMs) for detecting VUV argon scintillation light without wavelength shifting. Here, using a customized cryogenic amplifier design, we operated two models of VUV4 SiPMs inside liquid argon and thoroughly examined their direct sensitivities to liquid argon scintillation. In addition to describing their cryogenic performance, we measured a photon detection efficiency of 14.7+1.1–2.4% and 17.2+1.6–3.0% at 128 nm for these two VUV4 models for operation at 4 V of overvoltage, with the main uncertainty arising from the SiPM reflectivity for VUV light.

Pershing, Teal↗

Constraints on the Fundamental String Coupling from B-Mode Experiments

We study signatures of cosmic superstring networks containing strings of multiple tensions and Y junctions, on the cosmic microwave background (CMB) temperature and polarization spectra. Focusing on the crucial role of the string coupling constant g{sub s}, we show that the number density and energy density of the scaling network are dominated by different types of string in the g{sub s}{approx}1 and g{sub s}<<1 limits. This can lead to an observable shift in the position of the B-mode peak--a distinct signal leading to a direct constraint on g{sub s}. We forecast the joint bounds on g{sub s} and the fundamental string tension {mu}{sub F} from upcoming and future CMB polarization experiments, as well as the signal to noise in detecting the difference between B-mode signals in the limiting cases of large and small g{sub s}. We show that such a detectable shift is within reach of planned experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Decision-directed detector for overlapping PCM/NRZ signals.

A decision-directed (DD) technique for the detection of overlapping PCM/NRZ signals in the presence of white Gaussian noise is investigated. The performance of the DD detector is represented by probability of error Pe versus input signal-to-noise ratio (SNR). To examine how much improvement in performance can be achieved with this technique, Pe's with and without DD feedback are evaluated in parallel. Further, analytical results are compared with those found by Monte Carlo simulations. The results are in good agreement.

Wang, C. D.↗

Block Island Acoustic Data Analysis and Peak Detection Tools

This dataset contains acoustic signal analysis tools and processed datasets for pile driving noise characterization during Block Island Wind Farm construction (October 25, 2015), including peak detection algorithms, signal extraction methods, and visualization products for multi-channel hydrophone array data.

17 WIND ENERGY↗

A coherent method for the detection and parameter estimation of continuous gravitational wave signals using a pulsar timing array

The use of a high precision pulsar timing array is a promising approach to detecting gravitational waves in the very low frequency regime (10{sup –6}-10{sup –9} Hz) that is complementary to ground-based efforts (e.g., LIGO, Virgo) at high frequencies (∼10-10{sup 3} Hz) and space-based ones (e.g., LISA) at low frequencies (10{sup –4}-10{sup –1} Hz). One of the target sources for pulsar timing arrays is individual supermassive black hole binaries which are expected to form in galactic mergers. In this paper, a likelihood-based method for detection and parameter estimation is presented for a monochromatic continuous gravitational wave signal emitted by such a source. The so-called pulsar terms in the signal that arise due to the breakdown of the long-wavelength approximation are explicitly taken into account in this method. In addition, the method accounts for equality and inequality constraints involved in the semi-analytical maximization of the likelihood over a subset of the parameters. The remaining parameters are maximized over numerically using Particle Swarm Optimization. Thus, the method presented here solves the monochromatic continuous wave detection and parameter estimation problem without invoking some of the approximations that have been used in earlier studies.

79 ASTRONOMY AND ASTROPHYSICS↗

The X-Ray Spectrum of WZ Sagittae

We carried out an Advanced Satellite for Cosmology and Astrophysics (ASCA) observation of WZ Sagittae, to obtain the first X-ray spec- trum and to search for an X-ray counterpart near the well-known optical signal of 27.87 s. At around the same epoch, we carried out a similar search in ultraviolet radiation with the Faint Object Spectrograph (FOS) aboard the Hubble Space Telescope (HST). These experiments were done to test the hypothesis that the signal arises from rapid white dwarf rotation. The result generally confirmed that hypothesis, because signals were apparently detected at 27.87 s in both UV and hard X-ray light. But the detailed results were somewhat confusing, not exactly as simple as we dreamed in the proposal. The X-ray signal only emerges with fairly subtle methods of data analysis: either a "period-biased" search, or a sorting of X-ray photons into hard/soft - thus the detections are slightly marred by the taint of a posterz'ori reasoning. The UV data suffer a different but also worrisome problem: although 27.87 s is definitely detected, it's weaker than two other signals, at 28.22 and 29.69 s. That's quite surprising - we expected that the UV power spectrum would be simple, on the grounds that the UV flux distribution is nearly a pure white dwarf. Considered in isolation, such behavior from a white dwarf should be considered evidence for the pulsation hypothesis. The X-ray spectrum was interesting, mostly by virtue of what it did not show. It was essentially a pure thermal bremsstrahlung with kT = 5 keV, with only a very weak Fe K complex. This probably signifies origin near the central white dwarf and heating from accretion (propellor heating farther out would give lower densities and more cooling by emission lines). We published a paper reporting most of these details (Patterson et al. (1998), PASP, 110, 403), Much of the world accepts now that WZ Sge contains a rapidly spinning white dwarf - the fastest spin of any accreting white dwarf.

Patterson, Joseph↗

Correlation between human observer performance and model observer performance in differential phase contrast CT

Purpose: With the recently expanding interest and developments in x-ray differential phase contrast CT (DPC-CT), the evaluation of its task-specific detection performance and comparison with the corresponding absorption CT under a given radiation dose constraint become increasingly important. Mathematical model observers are often used to quantify the performance of imaging systems, but their correlations with actual human observers need to be confirmed for each new imaging method. This work is an investigation of the effects of stochastic DPC-CT noise on the correlation of detection performance between model and human observers with signal-known-exactly (SKE) detection tasks.Methods: The detectabilities of different objects (five disks with different diameters and two breast lesion masses) embedded in an experimental DPC-CT noise background were assessed using both model and human observers. The detectability of the disk and lesion signals was then measured using five types of model observers including the prewhitening ideal observer, the nonprewhitening (NPW) observer, the nonprewhitening observer with eye filter and internal noise (NPWEi), the prewhitening observer with eye filter and internal noise (PWEi), and the channelized Hotelling observer (CHO). The same objects were also evaluated by four human observers using the two-alternative forced choice method. The results from the model observer experiment were quantitatively compared to the human observer results to assess the correlation between the two techniques.Results: The contrast-to-detail (CD) curve generated by the human observers for the disk-detection experiments shows that the required contrast to detect a disk is inversely proportional to the square root of the disk size. Based on the CD curves, the ideal and NPW observers tend to systematically overestimate the performance of the human observers. The NPWEi and PWEi observers did not predict human performance well either, as the slopes of their CD curves tended to be steeper. The CHO generated the best quantitative agreement with human observers with its CD curve overlapping with that of human observer. Statistical equivalence between CHO and humans can be claimed within 11% of the human observer results, including both the disk and lesion detection experiments.Conclusions: The model observer method can be used to accurately represent human observer performance with the stochastic DPC-CT noise for SKE tasks with sizes ranging from 8 to 128 pixels. The incorporation of the anatomical noise remains to be studied.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fast and sensitive detection of an oscillating charge

We investigate the high-frequency operation of a percolation field effect transistor to monitor microwave excited single trapped charge. Readout is accomplished by measuring the effect of the polarization field associated with the oscillating charge on the AC signal generated in the channel due to charge pumping. This approach is sensitive to the relative phase between the polarization field and the pumped current, which is different from the conventional approach relying on the amplitude only. Therefore, despite the very small influence of the single oscillating trapped electron, a large signal can be detected. Experimental results show large improvement in both signal-to-noise ratio and measurement bandwidth.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nowcasting Earthquakes: Imaging the Earthquake Cycle in California With Machine Learning

We propose a new machine learning-based method for nowcasting earthquakes to image the time-dependent earthquake cycle. The result is a timeseries that may correspond to the process of stress accumulation and release. The timeseries are constructed by using principal component analysis of regional seismicity. The patterns are found as eigenvectors of the cross-correlation matrix of a collection of seismicity timeseries in a coarse grained regional spatial grid (pattern recognition via unsupervised machine learning). The eigenvalues of this matrix represent the relative importance of the various eigenpatterns. Using the eigenvectors and eigenvalues, we compute the weighted correlation timeseries of the regional seismicity. This timeseries has the property that the weighted correlation generally decreases prior to major earthquakes in the region, and increases suddenly just after a major earthquake occurs. As in a previous paper, we find that this method produces a nowcasting timeseries that resembles the hypothesized regional stress accumulation and release process characterizing the earthquake cycle. We then address the problem of whether the timeseries contain information regarding future large earthquakes. For this, we compute a receiver operating characteristic and determine the decision thresholds for several future time periods of interest (optimization via supervised machine learning). We find that signals can be detected that can be used to characterize the information content of the timeseries. These signals may be useful in assessing present and near-future seismic hazards.

58 GEOSCIENCES↗

Neutrino signals from dark matter decay

We investigate different neutrino signals from the decay of dark matter particles to determine the prospects for their detection, and more specifically if any spectral signature can be disentangled from the background in present and future neutrino observatories. If detected, such a signal could bring an independent confirmation of the dark matter interpretation of the dramatic rise in the positron fraction above 10 GeV recently observed by the PAMELA satellite experiment and offer the possibility of distinguishing between astrophysical sources and dark matter decay or annihilation. In combination with other signals, it may also be possible to distinguish among different dark matter decay channels.

79 ASTRONOMY AND ASTROPHYSICS↗

Servo-controlled intravital microscope system

A microscope system is described for viewing an area of a living body tissue that is rapidly moving, by maintaining the same area in the field-of-view and in focus. A focus sensing portion of the system includes two video cameras at which the viewed image is projected, one camera being slightly in front of the image plane and the other slightly behind it. A focus sensing circuit for each camera differentiates certain high frequency components of the video signal and then detects them and passes them through a low pass filter, to provide dc focus signal whose magnitudes represent the degree of focus. An error signal equal to the difference between the focus signals, drives a servo that moves the microscope objective so that an in-focus view is delivered to an image viewing/recording camera.

Mansour, M. N.↗

Self-referenced continuous-variable quantum key distribution

Various technologies for continuous-variable quantum key distribution without transmitting a transmitter's local oscillator are described herein. A receiver on an optical transmission channel uses an oscillator signal generated by a light source at the receiver's location to perform interferometric detection on received signals. An optical reference pulse is sent by the transmitter on the transmission channel and the receiver computes a phase offset of the transmission based on quadrature measurements of the reference pulse. The receiver can then compensate for the phase offset between the transmitter's reference and the receiver's reference when measuring quadratures of received data pulses.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

ALMA Observations of α Centauri First Detection of Main-Sequence Stars at 3 mm Wavelength

The precise mechanisms that provide the non-radiative energy for heating the chromosphere and the corona of the Sun and those of other stars constitute an active field of research. By studying stellar chromospheres one aims at identifying the relevant physical processes. Defining the permittable extent of the parameter space can also serve as a template for the Sun-as-a-star. This feedback will probably also help identify stars that potentially host planetary systems that are reminiscent of our own. Earlier observations with Herschel and APEX have revealed the temperature minimum of Alpha Cen, but these were unable to spatially resolve the binary into individual components. With the data reported in this Letter, we aim at remedying this shortcoming. Furthermore, these earlier data were limited to the wavelength region between 100 and 870 um. In the present context, we intend to extend the spectral mapping (SED) to longer wavelengths, where the contrast between stellar photospheric and chromospheric emission becomes increasingly evident. The Atacama Large Millimeter submillimeter Array (ALMA) is particularly suited to point sources, such as unresolved stars. ALMA provides the means to achieve our objectives with both its high sensitivity of the collecting area for the detection of weak signals and the high spatial resolving power of its adaptable interferometer for imaging close multiple stars. This is the first detection of main-sequence stars at a wavelength of 3 mm. Furthermore, the individual components of the binary Alpha CenAB are clearly detected and spatially well resolved at all ALMA wavelengths. The high signal-to-noise ratios of these data permit accurate determination of their relative flux ratios, i.e., S(sub y(sup B)) / S(sub y(sup A))> = 0.54 +/- 0.04 at 440 μm, = 0.46 +/- 0.01 at 870 μm, and = 0.47 +/- 0.006 at 3.1 mm, respectively.. The previously obtained flux ratio of 0.44+/-0.18, which was based on measurements in the optical and at 70 μm, is consistent with the present ALMA results, albeit with a large error bar. The observed 3.1 mm emission greatly exceeds what is predicted from the stellar photospheres, and undoubtedly arises predominantly as free-free emission in the ionized chromospheric plasmas of both stars. Given the distinct difference in their cyclic activity, the similarity of their submm SEDs appears surprising.

Herschel↗

Non-contact optical system for detecting ultrasound waves from a surface

A system for detecting pressure, acoustic or ultrasound waves within an entity having a surface including the steps of attaching a signal converting material to the surface. The waves are generated by direct ejection from the surface, generation via energy deposition on the surface, generated spontaneously or, generated by directing light energy to the light absorbing target. The absorbing target subsequently generates acoustic pressure waves. The acoustic waves propagate to the surface of the entity and the signal converting material, wherein the acoustic pressure waves create vibrations in the signal converting material; and detecting the waves in the signal converting material with an optical detection system. Information about the absorbing target is obtained by the absorbing target reflecting the waves. The signal converting material can be a gel-like material containing optical elements, a multi-layer patch, or other material.

Demos, Stavros G.↗

Failure detection with uncertain models

In this paper the author considers the issue of robust failure detection. In one way or another all failure detection methods generate signals which tend to highlight the presence of particular failures if they have actually occurred. However, if any model uncertainties have effects on the observables which are at all like those of one or more of the failure modes, these will also be accentuated. Consequently the problem of robust failure detection is concerned with generating signals which are maximally sensitive to some effects (failures) and minimally sensitive to other (model errors). Previously announced in STAR as N83-32417

Lou, X.-C.↗

Characterizations of PAPR-Constrained Radar Waveforms for Optimal Target Detection

We propose to design a peak-to-average power ratio (PAPR) constrained transmit waveform that achieves the optimal performance (following the Neyman Pearson lemma) in detecting a target in the presence of signal-dependent interference. The direct time-domain approach allows straightforward characterizations of the correlation and PAPR properties of the designed signals, which are critically important to analyze the system performance in the presence of multiple targets and to assess the transmitter power-utilization, respectively. Therefore, instead of designing a transmit signal only for the optimal detection performance, we solve a biobjective Pareto-optimization problem, subjecting to the PAPR and total energy constraints, in order to simultaneously optimize the detection and cross-correlation performances. With extensive numerical examples, we demonstrate that PAPR-constrained signals produce nearly optimum detection performance even with a strict PAPR requirement, and also highlight the conflicting behavior of the detection and correlation performances.

Sen, Satyabrata↗

TU-FG-BRB-08: Challenges, Limitations and Future Outlook Towards Clinical Translation of Proton Acoustic Range Verification

Purpose: To report our investigations of proton acoustic imaging, including computer simulations and preliminary experimental studies at clinical facilities. The ultimate achievable accuracy, sensitivity and clinical translation challenges are discussed. Methods: The acoustic pulse due to pressure rise was estimated using finite element model. Since the ionoacoustic pulse is highly dependent on the proton pulse width and energy, multiple pulse widths were studied. Based on the received signal spectrum at piezoelectric ultrasound transducer with consideration of random thermal noise, maximum spatial resolution of the proton-acoustic imaging modality was calculated. The simulation studies defined the design specifications of the system to detect proton acoustic signal from Hitachi and Mevion clinical machines. A 500 KHz hydrophone with 100 dB amplification was set up in a water tank placed in front of the proton nozzle A 40 MHz data acquisition was synchronized by a trigger signal provided by the machine. Results: Given 30–800 mGy dose per pulse at the Bragg peak, the minimum number of protons detectable by the proton acoustic technique was on the order of 10×10^6 per pulse. The broader pulse widths produce signal with lower acoustic frequencies, with 10 µs pulses producing signals with frequency less than 100 kHz. As the proton beam pulse width increases, a higher dose rate is required to measure the acoustic signal. Conclusion: We have established the minimal detection limit for protonacoustic range validation for a variety of pulse parameters. Our study indicated practical proton-acoustic range verification can be feasible with a pulse shorter than 10 µs, 5×10^6 protons/pulse, 50 nA beam current and a highly sensitive ultrasonic transducer. The translational challenges into current clinical machines include proper magnetic shielding of the measurement equipment, providing a clean trigger signal from the proton machine, providing a shorter proton beam pulse and higher dose per pulse.

60 APPLIED LIFE SCIENCES↗

Refine your search to explore more results.