Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sensitivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Energy sensitization of acceptors and donors in organic photovoltaics

Disclosed herein are organic photosensitive optoelectronic devices comprising acceptor and/or donor sensitizers to increase absorption and photoresponse of the photoactive layers of the devices. In particular, devices herein include at least one acceptor layer and at least one donor layer, wherein the acceptor layer may comprise a mixture of an acceptor material and at least one sensitizer, and the donor layer may comprise a mixture of a donor material and at least one sensitizer. Methods of fabricating the organic photosensitive optoelectronic devices are also disclosed.

14 SOLAR ENERGY↗

Enhancing the sensitivity of the LUX-ZEPLIN (LZ) dark matter experiment to low energy signals

Two-phase xenon detectors, such as that at the core of the forthcoming LZ dark matter experiment, use photomultiplier tubes to sense the primary (S1) and secondary (S2) scintillation signals resulting from particle interactions in their liquid xenon target. This paper describes a simulation study exploring two techniques to lower the energy threshold of LZ to gain sensitivity to low-mass dark matter and astrophysical neutrinos, which will be applicable to other liquid xenon detectors. The energy threshold is determined by the number of detected S1 photons; typically, these must be recorded in three or more photomultiplier channels to avoid dark count coincidences that mimic real signals. To lower this threshold: a) we take advantage of the double photoelectron emission effect, whereby a single vacuum ultraviolet photon has a $\sim20\%$ probability of ejecting two photoelectrons from a photomultiplier tube photocathode; and b) we drop the requirement of an S1 signal altogether, and use only the ionization signal, which can be detected more efficiently. For both techniques we develop signal and background models for the nominal exposure, and explore accompanying systematic effects, including the dependence on the free electron lifetime in the liquid xenon. When incorporating double photoelectron signals, we predict a factor of $\sim 4$ sensitivity improvement to the dark matter-nucleon scattering cross-section at $2.5$ GeV/c$^2$, and a factor of $\sim1.6$ increase in the solar $^8$B neutrino detection rate. Dropping the S1 requirement may allow sensitivity gains of two orders of magnitude in both cases. Finally, we apply these techniques to even lower masses by taking into account the atomic Migdal effect; this could lower the dark matter particle mass threshold to $80$ MeV/c$^2$.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhancing the sensitivity of the LUX-ZEPLIN (LZ) dark matter experiment to low energy signals

Two-phase xenon detectors, such as that at the core of the forthcoming LZ dark matter experiment, use photomultiplier tubes to sense the primary (S1) and secondary (S2) scintillation signals resulting from particle interactions in their liquid xenon target. This paper describes a simulation study exploring two techniques to lower the energy threshold of LZ to gain sensitivity to low-mass dark matter and astrophysical neutrinos, which will be applicable to other liquid xenon detectors. The energy threshold is determined by the number of detected S1 photons; typically, these must be recorded in three or more photomultiplier channels to avoid dark count coincidences that mimic real signals. To lower this threshold: a) we take advantage of the double photoelectron emission effect, whereby a single vacuum ultraviolet photon has a $\sim20\%$ probability of ejecting two photoelectrons from a photomultiplier tube photocathode; and b) we drop the requirement of an S1 signal altogether, and use only the ionization signal, which can be detected more efficiently. For both techniques we develop signal and background models for the nominal exposure, and explore accompanying systematic effects, including the dependence on the free electron lifetime in the liquid xenon. When incorporating double photoelectron signals, we predict a factor of $\sim 4$ sensitivity improvement to the dark matter-nucleon scattering cross-section at $2.5$ GeV/c$^2$, and a factor of $\sim1.6$ increase in the solar $^8$B neutrino detection rate. Dropping the S1 requirement may allow sensitivity gains of two orders of magnitude in both cases. Finally, we apply these techniques to even lower masses by taking into account the atomic Migdal effect; this could lower the dark matter particle mass threshold to $80$ MeV/c$^2$.

Akerib, DS↗

Enabling Computation on Sensitive Data in International Safeguards with Privacy-Preserving Encryption Techniques

Privacy-preserving machine learning is a field of study that explores how to protect and preserve the privacy of sensitive data while allowing the data to be used by machine learning algorithms. This field has had substantial industry investment due to heightened concerns about privacy in the technology industry, with a focus in two broad application areas: financial services and healthcare. Numerous privacy-preserving methods have also been proposed for international safeguards, but they have been difficult to enact because the data they require is con- sidered sensitive or proprietary by the nuclear facility operator. This work examines how current privacy-preserving approaches might be used to enable the International Atomic Energy Agency (IAEA) to use that data to contribute to a safeguards conclusion about a state while giving nuclear operators confidence that their sensitive data is adequately protected. This paper begins by exploring several broad categories of privacy-preserving techniques including homomorphic encryption, secure multiparty computation, secure enclaves, and zero-knowledge proofs. Then we discuss some of the security considerations related to using these methods, potential use cases, and a conceptual system design for applying privacy-preserving methods in international safeguards.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Development of a New Fixed-source Sensitivity Tally Capability in the MCNP® code [Abstract]

The development of a new fixed-source sensitivity tally capability is currently underway in the MCNP code. In recent research and development efforts that utilize machine learning to both seek problematic nuclear data as well as design experiments optimized to improve the nuclear data, the adjoint-weighted k-eigenvalue sensitivity tally capabilities have been heavily essential. In this paper, the motivation to expand the sensitivity tally capabilities beyond k-eigenvalues toward diverse fixed-source problems along with preliminary results and verification will be discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

CHERENKOV CONVERTER FOR LARGE DYNAMIC RANGE, HIGH SENSITIVITY DETECTORS FOR USE ON WIRE-SCANNERS

We are developing a wire-scanner with a dynamic range of 1e+6 or larger. In addition to the large dynamic range (LDR), high sensitivity is very desirable so that measurements can be made with a small amount of beam or small duty cycle beam. This high sensitivity requirement makes photo multiplier tubes (PMT) with low background levels, the preferred detector. Low dark current PMTs have maximum quantum efficiency in the visible wavelength range. We describe a converter where Cherenkov radiation (CR) is used to generate visible photons from electrons and positrons that are present due to wire-beam interaction. An optical system used to collect and couple the CR into an optical fiber is also described. The high directivity of the CR is used in such a way that, when CR in the radiating medium is generated by particles not directed from the wire-beam interaction point to the converter, the CR is not coupled into the optical fiber and therefore does not create background for the wire-scanner measurements. It is envisioned that the optical fiber will be used to deliver the visible photons to the PMT located outside of the accelerator tunnel to further reduce the background level. Sensitivities to the refractive index of the radiating medium, alignment and mechanical fabrication tolerances are also presented. *Work supported by US DOE office of Basic Energy Sciences under the early career program; DOE award number FWP#JLAB-BES11-05

Gubeli, Joseph↗

Model Sensitivities in the Extraction of Qw(p) from PVES Data

As the Qweak collaboration prepares to unblind our final result, studies have been performed to quantify the sensitivities of the fit used to extract the proton's weak charge Qw(p) from the body of existing parity-violating electron scattering (PVES) data. The results of these sensitivity studies will be used to freeze choices associated with the fitting procedure before unblinding. Under study are the effects of including PVES data on D2 and He targets in the fit, and restrictions on the angular and Q2 range of the data in the fit. The impact of different electromagnetic form factor (EM FF) fits, and the separate impact of the uncertainties associated with the EM FF fits themselves on the fit used to extract Qw(p) from the body of (mostly) e? p data have been studied. The impact of recent lattice QCD calculations of charge symmetry effects on our fit result will be assessed. A comparison will be made using recent lattice calculations of ?s and ?s in our Qw(p) determination, or floating these parameters in our fit. The dipole mass sensitivity in the strange and axial FFs will be assessed. The impact of floating the isoscalar and/or isovector axial FFs to theory or floating them freely in the fit will also be studied.

Smith, Gregory↗

Large active-area superconducting microwire detector array with single-photon sensitivity in the near-infrared

Superconducting nanowire single photon detectors (SNSPDs) are the highest-performing technology for time-resolved single-photon counting from the UV to the near-infrared. The recent discovery of single-photon sensitivity in micrometer-scale superconducting wires is a promising pathway to explore for large active area devices with application to dark matter searches and fundamental physics experiments. We present 8-pixel $1 mm^2$ superconducting microwire single photon detectors (SMSPDs) with $1\,\mathrm{\mu m}$-wide wires fabricated from WSi and MoSi films of various stoichiometries using electron-beam and optical lithography. Devices made from all materials and fabrication techniques show saturated internal detection efficiency at 1064 nm in at least one pixel, and the best performing device made from silicon-rich WSi shows single-photon sensitivity in all 8 pixels and saturated internal detection efficiency in 6/8 pixels. This detector is the largest reported active-area SMSPD or SNSPD with near-IR sensitivity published to date, and the first report of an SMSPD array. By further optimizing the photolithography techniques presented in this work, a viable pathway exists to realize larger devices with $cm^2$-scale active area and beyond.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Particle-image Velocimetry Sensitivity through Automatic Differentiation

A commonly encountered difficulty in modern experimental fluid dynamics experiments is the need for full-flow visualization and measurement; traditional techniques such as hot-wire probes and laser Doppler velocimetry cannot provide such information without difficult scanning procedures. Particle-image velocimetry (PIV) is a measurement technique which can overcome this spatial limitation to provide real-time three-dimensional fluid velocity vectors for an entire plane within the flow, as opposed to a single point that is provided by other measurement techniques. To accomplish this, a PIV system seeds the fluid flow with tracer particles; these must have nearly the same density as that of the fluid and a high drag coefficient to ensure that they follow the fluid flow without deviation. A laser is sent through optics to expand its beam into a sheet which illuminates the plane of interest in the fluid. The particles reflect more light than the fluid, and their image is recorded using a high speed camera. Due to limitations in bandwidth, video cannot be taken fast enough to be useful, and instead pairs of images are captured with a known separation in time. The illuminated particles will move between the two images taken by the camera, and their relative motion can be used to compute the fluid velocity at that point. When a single camera is used, only two-dimensional velocity vectors can be computed, but with the addition of another camera this can be improved to full three-dimensional vectors. The flow's time evolution can be measured by taking series of image pairs and processing each pair to get the velocity field at the time between each image pair. Only the two-dimensional version will be considered in this work. To compute the velocity vectors of the flow, the images are broken up into interrogation regions, usually in a uniform grid. In the most basic PIV algorithm, corresponding regions in the image pairs are cross-correlated to compute the most likely displacement from one image to the next. This is used since the cross correlation will achieve a maximum value when the two interrogation regions line up the best. The location of the peak in the correlation map and scaling information for the optical setup is used to compute the particle displacement from one image to the next. This process is similar to holding two semi-transparent images and moving one until they match as well as possible. Sub-pixel displacements between images can be obtained by fitting a Gaussian function to the correlation peak. Knowing the displacement vector for each set of interrogation regions in the image pair, it is a simple matter to divide by the time gap between the two images to compute the fluid velocity at the point in time and space. Since there are many interrogation regions in each image pair, the velocity field for a sheet is sampled according to the arrangement of the interrogation regions. The sensitivity of the final computed vector to the input images is difficult to compute, and has led most considerations of uncertainty in the PIV field to apply Monte Carlo methods and correlations to quantify the systematic and random errors which result from application of various PIV algorithms. In this work, automatic differentiation (AD) has been used to trace the dependence of velocity vectors computed using the correlation-peak PIV algorithm back to the input values given to an artificial image generator. These initial results form the foundation for continued work in the application of AD to algorithms in PIV. They demonstrate that AD methods can be successfully applied to PIV algorithms without undue complexity. The derivatives of each individual vector with regard to the coefficients of the velocity field used to create the artificial images can be computed and the statistics of them considered collectively, or correlated between each other to quantify the effectiveness of a PIV algorithm. With the initial implementation complete, adding extra algorithms is relatively simple and considerable data can be generated for analysis. It is hoped that application of these methods can lead to improved PIV algorithms which demonstrate better sensitivity to small variations in particle displacement. While these methods can be used as an analysis tool for refinement of new algorithms, computation of actual resultant vector sensitivities to input images' individual pixels is the next logical step of this work. Such information will be analyzed with experimental data to produce a better understanding of how output vectors' uncertainty relates to the actual image pairs, and lead to automatic bad vector removal. (authors)

42 ENGINEERING↗

Analytic Sensitivity Coefficients for General Multigroup Infinite Medium k-Eigenvalue Problems

The general multigroup infinite medium k-eigenvalue neutron transport equation is used to derive analytic expressions for the infinite medium k-eigenvalue, the scalar neutron flux and adjoint, and the sensitivity of $k$ ∞ to perturbations in the multigroup nuclear data of a single species isotropic elastic scattering material. In the appendix, we present the multigroup nuclear data for U-235 and U-238 along with the corresponding k-eigenvalue, flux, adjoint, and sensitivity profiles, which include the sensitivity of $k$ ∞ to the total, fission, capture, and scattering macroscopic cross sections as well as to the group-to-group scattering cross section matrix, group neutron production, and the unconstrained and constrained fission neutron energy distribution.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Simulating Alpha Particles Incident on MKID Chips for Quantum Sensitivity Analysis

Superconducting quantum devices, such as microwave kinetic inductance detectors (MKIDs), are highly sensitive instruments used in quantum computing and advanced sensing technologies. However, their extreme sensitivity also makes them vulnerable to background noise from natural sources like radiation. One significant contributor to this noise is alpha particles emitted by 210Po, a radon decay daughter that accumulates on surfaces near the detector. This project investigates how alpha particles emitted from 210Po interact with MKID chips. These particles can deposit energy on the detector surface, disrupting its operation and generating false signals. Understanding the energy and behavior of these particles is crucial for improving the design and reliability of quantum devices. To explore this, we first modeled the decay chain starting from 210Pb to 210Po using differential equations. This allowed us to predict how the activity of alpha-emitting isotopes changes over time, reaching a steady state after about two years. Next, we simulated alpha particle interactions with the MKID chip using the Geant4 software toolkit. We built a detailed computer model of the detector housing, including the copper lid where alpha particles originate, the silicon chip, and a thin aluminum sensor layer. Alpha particles were emitted isotropically from just beneath the copper lid’s surface, mimicking natural decay conditions. The simulation tracked how these particles deposit energy on the chip, generating electron-hole pairs and phonons. The results provide insight into the behavior of the resultant electron-hole pairs and phonons, giving us a clear understanding of the energy deposition distribution on the chip. This work supports efforts to mitigate background noise in superconducting sensors, advancing their use in quantum computing and sensitive physics experiments.

Hall, Matthew [Fermilab; UCLA]↗

Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme

The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector. *************************************** AUTHOR = Slater, Bethany University of Liverpool b.slater2@liverpool.ac.uk TITLE = Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme PAGES = 218 NOTE = Ph.D. University of Liverpool March 2026 ABSTRACT = The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector.

Slater, Bethany [Liverpool U.]↗

Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme

The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector. *************************************** AUTHOR = Slater, Bethany University of Liverpool b.slater2@liverpool.ac.uk TITLE = Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme PAGES = 218 NOTE = Ph.D. University of Liverpool March 2026 ABSTRACT = The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector.

Slater, Bethany [Liverpool U.]↗

Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme

The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector. *************************************** AUTHOR = Slater, Bethany University of Liverpool b.slater2@liverpool.ac.uk TITLE = Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme PAGES = 218 NOTE = Ph.D. University of Liverpool March 2026 ABSTRACT = The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector.

Slater, Bethany [Liverpool U.]↗

Sensitivity of Next-Generation CMB Surveys to Neutrinos and Other Light Relics

Neutrinos and other light relics leave characteristic imprints in the cosmic microwave background anisotropies, making their observation a sensitive probe of the particle content and thermal history of the early universe. The energy density in these relativistic species is parameterized by their effective number $N_\mathrm{eff}$. Measuring this parameter at the percent level, which is a long-standing science goal of CMB-S4 and other experiments, would test a wide range of well-motivated physics within and beyond the Standard Model of particle physics. In this paper, we present Fisher-matrix forecasts of the projected sensitivity to $N_\mathrm{eff}$ of several CMB-S4 survey configurations considered during its extensive design phase. The conceptual design reaches $σ(N_\mathrm{eff}) < 0.03$ over its seven-year observing period, while the revised configuration achieves the same precision over a longer timescale. We complement these results with a cosmic-variance-limited survey over the same multipole range to quantify the room for improvement accessible with additional instrumental, observational, and theoretical efforts. Finally, we discuss the broad implications of precise $N_\mathrm{eff}$ measurements for the radiation sector, big bang nucleosynthesis, light thermal relics, and other early-universe physics. The forecasts presented in this work are performed with the publicly released DRAFT (Dark Radiation Anisotropy Flowdown Team) tool. It provides an end-to-end pipeline from simulated foreground maps and component separation to delensing and projected sensitivities for any cosmological parameter, and it can be directly applied to other cosmic microwave background survey designs.

Trendafilova, Cynthia [Case Western Reserve U., CE↗

Refined Sensitivity Estimates for Single-Molecule Magnet Dark Matter Detectors

We revisit the sensitivity of Single Molecule Magnet (SMM) crystals as detectors for low-mass dark matter. In previous work, we established the concept of the ``magnetic bubble chamber'', where energy deposited by dark matter triggers a magnetic avalanche in a metastable crystal. The original sensitivity estimates relied on a conservative criterion requiring the spin relaxation time to be strictly shorter than the thermal diffusion time. Here, we demonstrate that this criterion effectively ignores the stochastic nature of spin relaxation. We derive a refined analytic estimate which accounts for the fraction of spins that relax even when diffusion is fast. We show that the Zeeman energy released by this fraction contributes to local heating, significantly lowering the energy threshold for avalanche formation. We present simulation results confirming this effect and report on experimental verification of the assumed low-temperature thermal properties of two representative SMM crystals, Mn$_{12}$-acetate and Mn$_{32}$. Together, these efforts extend this pathfinder program toward the realization of SMM-based detectors with controlled material properties and enhanced dark matter sensitivity.

Eberhardt, Andrew [Tokyo U., IPMU]↗

Beyond $Δm^2$: Absolute Mass Sensitivity in Neutrino Oscillations

Conventional wisdom says that neutrino oscillations measure only mass-squared differences and not the absolute neutrino mass scale. This is true, however, only at leading order in the expansion parameters $m_i/E$, the ratios of the neutrino masses $m_i$ ($i=1,2,3$) to the neutrino energy $E$. At next-to-leading order, the oscillation phase includes terms proportional to $m_i^4-m_j^4 = Δm^2_{ij}(m_i^2+m_j^2)$, and is therefore sensitive to the absolute mass scale. In this paper, we derive the next-to-leading-order corrections using a wave-packet treatment and taking into account the neutrino-production kinematics. We then apply this result to reactor antineutrinos and find that the JUNO experiment is sensitive to neutrino masses of a few hundred keV. While not competitive with existing bounds from beta decay, electron capture, and cosmology, neutrino oscillations provide a novel, complementary probe of the neutrino mass scale, with sensitivity to a different combination of neutrino masses.

Alves, Gustavo F.S. [Fermilab; Argonne; Northweste↗

Aryl Bridged 1-Hydroxypyridin-2-one: Effect of the Bridge on the Eu(III) Sensitization Process

The efficiency of Eu3+ luminescence by energy transfer from an antenna ligand can be strongly dependent on the metal ion coordination geometry. The geometric component of the Eu(III) sensitization has been probed using series of tetradentate 1,2-HOPO derivatives that are connected by bridges of varying length and geometry. The ligands are N,N'-(1,2-phenylene)bis(1-hydroxy-6-oxo-1,6-dihydropyridine-2-carboxamide) for the ligand (L{sup 1}), 1-hydroxy-N-(2-(1-hydroxy-6-oxo-1,6-dihydropyridine-2-carboxamido)benzyl)-6-oxo-1,6-dihydropyridine-2-carboxamide (L{sup 2}) and N,N'-(1,2-phenylenebis(methylene))bis(1-hydroxy-6-oxo-1,6-dihydropyridine-2-carboxamide) (L{sup 3}). Spectroscopic characterization of both the Gd(III) and Eu(III) metal complexes, TD-DFT analysis of model compounds and evaluation of the kinetic parameters for the europium emission were completed. Some striking differences were observed in the luminescence quantum yield by altering the bridging unit. The [Eu(L{sup 2}){sub 2}]{sup -} derivative shows efficient sensitization coupled with good metal centered emission. For [Eu(L{sup 3}){sub 2}]{sup -}, the large quenching of the luminescence quantum yield compared to [Eu(L{sup 2}){sub 2}]{sup -} is primarily a result of one inner sphere water molecule bound to the europium cation while for [Eu(L{sup 1}){sub 2}]{sup -}, the low luminescence quantum yield can be attributed to inefficient sensitization of the europium ion.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Refine your search to explore more results.