Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sample”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Structural investigation and applications of glassy sodium phosphate including the kinetics of dissolution rates and spectral analysis of the prepared samples with a focus on their effects on water treatment

This paper discuss the preparation of the binary system of Phosphate Based Glass (PBG) xP{sub 2}O{sub 5}–(100 − x) Na{sub 2}O mol% and investigates the compositions that form glassy matrix. It is found that x in the range between x = 40–60 mol% and divided in to 5 glass samples (x = 40, 45, 50, 55, 60) and for compositions of 40 > x > 60 no glassy matrix is formed. The intensities of the peak centers of the IR spectra of sodium phosphate glasses and the suggested vibrational modes of structural phosphate chains, terminal groups and tabulated data imply a shift in absorption bands with increasing the Na{sub 2}O mol% content. The amount of bridging phosphorous, shows a maximum value for the glass containing 60 mol% Na{sub 2}O due to the depolymerization of the phosphate matrix with increasing Na{sub 2}O content from 40 to 60 mol% via a breakdown of some terminal bonds (P=O) in the glass network which decreases the bond strength, consequently the peak center is shifted towards lower wave number. Essentially, five compositions of glassy samples were investigated: (x = 40, 45, 50, 55, and 60) mol%. The kinetics of dissolution rate were investigated by two ways: 1—the weight loss data and 2—electrical properties of the solution (pH, Electrical Conductivity) leached by the glass sample in to the deionized water. It is found that with increasing the Na{sub 2}O% content, the pH values, the dissolution rate and the solubility are increasing. It could be noticed that the ionic levels increased with the immersion time and were directly related to the solubility of the glasses. The highest in solubility (x = 40) is the highest in EC and pH values caused by high Na{sub 2}O%. By studying the effect of PBG on the real water medium physical characteristics the following results were achieved: Softening of (Treated drinking water, Nile raw water) by removal of hardness (Ca, Mg) by x = 50; 50% P{sub 2}O{sub 5}–50% Na{sub 2}O, Sequestering and agglomerating of (groundwater, wastewater) of some heavy metals as (Fe, Mn) up to 100% removal by x = 60; 60% P{sub 2}O{sub 5}–40% Na{sub 2}O and the electrical properties (pH, EC) were discussed. Results are assuring the possibility of applying PBG for groundwater treatment of high Fe and Mn content. The data show that municipal groundwater supplies become acceptable according to the guidelines of American Chemistry Council for safe drinking water by using of polyphosphates for water treatment.

54 ENVIRONMENTAL SCIENCES↗

Ferromagnetism and Persistent Currents in Finely Dispersed Highly Oriented Pyrolytic Graphite Samples

Synthesis of finely dispersed graphite powders is described and results of their investigations by the methods of electron microscopy and magnetometry are presented. The samples have been prepared from crystal highly oriented pyrolytic graphite by grinding in an inert atmosphere for a long time with subsequent annealing at 400°C for 24 h in air or in vacuum. It is demonstrated that annealing of the powder in vacuum leads to a considerable increase in the ferromagnetic component associated with the formation of edge defects of zigzag type. The phenomenon of magnetic flux trapping is manifested in the samples annealed both in air and in vacuum upon cooling down to 10 K in a magnetic field that is indicative of the formation of superconducting regions in the samples.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The Integration of Plant Sample Analysis, Laboratory Studies, and Thermodynamic Modeling to Predict Slag-Matte Equilibria in Nickel Sulfide Converting

The Kalgoorlie Nickel Smelter (KNS) produces low Fe, low Cu nickel matte in its Peirce–Smith converter operations. To inform process development in the plant, new fundamental data are required on the effect of CaO in slag on the distribution of arsenic between slag and matte. A combination of plant sample analysis, high-temperature laboratory experiments, and thermodynamic modeling was carried out to identify process conditions in the converter and to investigate the effect of slag composition on the chemical behavior of the system. The high-temperature experiments involved re-equilibration of industrial matte-slag-lime samples at 1498 K (1225 °C) and P(SO{sub 2}) = 0.12 atm on a magnetite/quartz substrate, rapid quenching in water, and direct measurement of phase compositions using electron probe X-ray microanalysis (EPMA) and laser ablation–inductively coupled plasma–mass spectrometry (LA-ICP-MS). A private thermodynamic database for the Ca-Cu-Fe-Mg-Ni-O-S-Si-(As) system was used together with the FactSage software package to assist in the analysis. Thermodynamic predictions combined with plant sample characterization and the present experimental data provide a quantitative basis for the analysis of the effect of CaO fluxing on the slag-matte thermochemistry during nickel sulfide converting, in particular on the spinel liquidus and the distribution of elements between slag and matte as a function of CaO addition.

36 MATERIALS SCIENCE↗

Relationship between Grain Size and Sample Thickness on the Creep-Rupture Performance of Thin Metallic Sheets of INCONEL Alloy 740H

A study was conducted on INCONEL® alloy 740H® to examine the role of grain size and sheet thickness on the alloy’s creep-rupture behavior. Three different starting sheet thicknesses were utilized and multiple heat-treatment conditions anticipated for compact heat exchanger (CHX) manufacturing were applied to produce a range of grain sizes. Creep-rupture testing was conducted at 750 °C for times up to about 6000 h and the results were compared to wrought databases. The data show that both creep strength and ductility were important factors in the overall creep performance of the sheets. Reductions in performance were observed due either to accelerated creep when grain size was fine or loss of rupture ductility when grain sizes approached the sheet thickness. Some combinations of heat-treatment and thickness were able to produce typical expected wrought creep properties. Historically a ‘rule-of-thumb’ requirement for creep testing suggests 3-5 grains per sample minimum dimension to ensure homogeneous behavior. This research shows that to ensure representative wrought creep performance (i.e. no effect of sample size), the sample minimum cross-section should be 10 times the average ASTM grain size. Statistical analysis of the microstructures suggests the population of larger grains as a controlling feature in creep failure.

14 SOLAR ENERGY↗

Adaptive sampling quasi-Newton methods for zeroth-order stochastic optimization

Here, we consider unconstrained stochastic optimization problems with no available gradient information. Such problems arise in settings from derivative-free simulation optimization to reinforcement learning. We propose an adaptive sampling quasi-Newton method where we estimate the gradients using finite differences of stochastic function evaluations within a common random number framework. We develop modified versions of a norm test and an inner product quasi-Newton test to control the sample sizes used in the stochastic approximations and provide global convergence results to the neighborhood of a locally optimal solution. We present numerical experiments on simulation optimization problems to illustrate the performance of the proposed algorithm. When compared with classical zeroth-order stochastic gradient methods, we observe that our strategies of adapting the sample sizes significantly improve performance in terms of the number of stochastic function evaluations required.

97 MATHEMATICS AND COMPUTING↗

Use of an Open Port Sampling Interface Coupled to Electrospray Ionization for the On-Line Analysis of Organic Aerosol Particles

A simple design for an open port sampling interface coupled to electrospray ionization (OPSI-ESI) is presented for the analysis of organic aerosols. The design uses minimal modifications to a Bruker electrospray (ESI) emitter to create a continuous flow, self-aspirating open port sampling interface. Considerations are presented for introducing aerosol to the open port sampling interface including aerosol gas flow and solvent flow rates. The device has been demonstrated for use with an aerosol of nicotine as well as aerosol formed in the pyrolysis of biomass. Upon comparison with extractive electrospray ionization (EESI), this device has similar sensitivity with increased reproducibility by nearly a factor of three. The device has the form factor of a standard Bruker/Agilent ESI emitter and can be used without any further instrument modifications. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Initial Benchmarking of the Liquid Sampling-Atmospheric Pressure Glow Discharge-Orbitrap System Against Traditional Atomic Mass Spectrometry Techniques for Nuclear Applications

The integration of the liquid sampling-atmospheric pressure glow discharge (LS-APGD) ion source with Orbitrap mass spectrometers has resulted in new opportunities in the field of isotope ratio mass spectrometry. In a field that has been dominated by thermal ionization mass spectrometry (TIMS) and inductively coupled plasma mass spectrometry (ICP-MS) on quadrupole and scanning-mode sector field analyzer platforms for highly accurate and precise measurements, the LS-APGD-Orbitrap system offers a benchtop instrument capable of meeting the rigorous International Target Values for measurement uncertainty for uranium (U). In order to benchmark the LS-APGD-Orbitrap, a series of U certified reference materials with increasing {sup 235}U isotopic composition were analyzed. By using U samples ranging in enrichment from 1 to 80%, the ability of the system to measure isotope ratios over a wide range is demonstrated. This analysis represents the first time that the LS-APGD-Orbitrap system has been used to analyze highly enriched U samples, allowing for the measurement of each of the U isotopes, including {sup 234}U and {sup 236}U-related species, which had not been achieved previously. Ultimately, the LS-APGD-Orbitrap system was able to measure CRM U-800 (assayed as {sup 235}U / {sup 238}U = 4.265622) as 4.266922, with a combined uncertainty, (u{sub c}), of 0.040%. These results are compared to those obtained using traditional elemental mass spectrometers including TIMS and ICP-MS-based instruments. The effectiveness of the LS-APGD-Orbitrap MS system for measuring U isotopes shows excellent promise in nuclear forensics, safeguards, and other nuclear weapon-based applications. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Grain growth competition during thin-sample directional solidification of dendritic microstructures: A phase-field study

Here we present the results of a comprehensive phase-field study of columnar grain growth competition in bi-crystalline samples in two dimensions (2D) and in three dimensions (3D) for small sample thicknesses allowing a single row of dendrites to form. We focus on the selection of grain boundary (GB) orientation during directional solidification in the steady-state dendritic regime, and study its dependence upon the orientation of two competing grains. In 2D, we map the entire orientation range for both grains, performing several simulations for each configuration to account for the stochasticity of GB orientation selection and to assess the average GB behavior. We find that GB orientation selection depends strongly on whether the primary dendrite growth directions have lateral components (i.e. components perpendicular to the axis of the temperature gradient) that point in the same or opposite directions in the two grains. Here, we identify a range of grain orientations in which grain selection follows the classical description of Walton and Chalmers. We also identify conditions that favor unusual overgrowth of favorably-oriented dendrites at a converging GB. We propose a simple analytical description that reproduces the average GB orientation selection from 2D simulations within statistical fluctuations of a few degrees. In 3D, we find a similar GB orientation selection as in 2D when secondary branches grow in planes parallel and perpendicular to the sample walls. Remarkably, quasi-2D behavior is also observed even when those perpendicular sidebranching planes are rotated by a finite azimuthal angle about the primary dendrite growth axis as long as the absolute values of those azimuthal angles are equal in both grains. In contrast, when the absolute values of those azimuthal angles differ markedly, we find that unusual overgrowth events at a converging GB are promoted by a high azimuthal angle in the least-favorably-oriented grain. We also find that diverging GBs can be strongly affected by those azimuthal angles, while converging GBs exhibit a weak dependence on those angles. Finally, for diverging GBs, GB orientation is also strongly affected by the relative signs of the lateral components of the primary dendrite growth directions in both grains.

36 MATERIALS SCIENCE↗

Analysis of new measurements of Calvert Cliffs spent fuel samples using SCALE 6.2

High quality experimental data for isotopic compositions in irradiated fuel are important to spent fuel applications, including nuclear safeguards, spent fuel storage, transportation, and final disposal. The importance of these data has been increasingly recognized in recent years, particularly as countries like Finland and Sweden plan to open the world’s first two spent fuel geological repositories in 2020s, while other countries, including the United States, are considering extended dry fuel storage options. Destructive and nondestructive measurements of a spent fuel rod segment from a Combustion Engineering 14 × 14 fuel assembly of the Calvert Cliffs Unit 1 nuclear reactor have been recently performed at Oak Ridge National Laboratory (ORNL). These ORNL measurements included two samples selected from adjacent axial locations of a fuel rod with initial enrichment of 3.038 wt% 235 U, which achieved burnups close to 43.5 GWd/MTU. More than 50 different isotopes of 16 elements were measured using high precision measurement methods. Various investigations have assessed the quality of the new ORNL measurement data, including comparison to previous measurements and to calculation results. Previous measurement data for samples from the same fuel rod measured at ORNL are available from experiments performed at Pacific Northwest National Laboratory in the United States and the Khoplin Radium Institute in Russia. Detailed assembly models were developed using the newly released SCALE 6.2 code package to simulate depletion and decay of the measured fuel samples. Furthermore, results from this work show that the new ORNL measurements provide a good quality radiochemical assay data set for spent fuel with relatively high burnup and long cooling time, and they can serve as good benchmark data for nuclear burnup code validation and spent fuel studies.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Effectiveness of multi-stage cooling processes in improving the CH 4 -hydrate saturation uniformity in sandy laboratory samples

Laboratory-created samples of methane hydrate (MH)-bearing media are a necessity because of the rarity and difficulty of obtaining naturally-occurring samples. The hypothesis that the inevitable heterogeneity in the phase saturations of the laboratory samples may lead to unreliable and non-repeatable results provided the impetus for us to undertake this study, which aimed to determine the conditions under which maximum uniformity can be achieved. To that end, we designed four experiments involving different multi-stage cooling regimes (in terms of their duration and number of stages) to induce MH formation under excess-water conditions. In the absence of direct visualization capabilities, we analysed the experimental results by means of numerical simulation, which provided high-resolution predictions of the spatial distributions of the phase saturations in the cores and enabled the estimation of the parameters controlling the kinetic MH-formation behaviour through history-matching. Analysis of the numerical results indicated that, under the conditions of the experiments and with the design of the reactor, significant heterogeneities in phase saturation distributions were observed in all cases, leading to the conclusion that it is not possible to obtain cores with uniform phase saturation. Additionally, contrary to expectations, heterogeneities increased with the number of cooling stages and the duration of cooling, and this was attributed to imperfect insulation of the upper part of the reactor. A set of simulations involving perfect insulation of the reactor top confirmed the validity of this assumption: (a) predicting the formation of high-uniformity MH-bearing cores that became more homogeneous as the number of cooling stages and the length of the cooling period increased; and (b) providing important information for the improvement of the standard design of the experimental apparatus for the laboratory creation of MH-bearing cores using the excess water method.

42 ENGINEERING↗

Direct observation of unstained wet biological samples by scanning-electron generation X-ray microscopy

Analytical tools of nanometre-scale resolution are indispensable in the fields of biology, physics and chemistry. One suitable tool, the soft X-ray microscope, provides high spatial resolution of visible light for wet specimens. For biological specimens, X-rays of water-window wavelength between carbon (284 eV; 4.3 nm) and oxygen (540 eV; 2.3 nm) absorption edges provide high-contrast imaging of biological samples in water. Among types of X-ray microscope, the transmission X-ray microscope using a synchrotron radiation source with diffractive zone plates offers the highest spatial resolution, approaching 15-10 nm. However, even higher resolution is required to measure proteins and protein complexes in biological specimens; therefore, a new type of X-ray microscope with higher resolution that uses a simple light source is desirable. Here we report a novel scanning-electron generation X-ray microscope (SGXM) that demonstrates direct imaging of unstained wet biological specimens. We deposited wet yeasts in the space between two silicon nitride (Si{sub 3}N{sub 4}) films. A scanning electron beam of accelerating voltage 5 keV and current 1.6 nA irradiates the titanium (Ti)-coated Si{sub 3}N{sub 4} film, and the soft X-ray signal from it is detected by an X-ray photodiode (PD) placed below the sample. The SGXM can theoretically achieve better than 5 nm resolution. Our method can be utilized easily for various wet biological samples of bacteria, viruses, and protein complexes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of sex, age, sampling time, and season on thyroid-stimulating hormone concentrations: A retrospective study

Highlights: • Serum TSH concentrations in women were significantly higher than in men. • TSH concentrations decreased during the summer while increased during the winter. • TSH concentrations decreased from 7 a.m. to 1 p.m. while increased from 1 p.m. to 4 p.m. • Sex, age, season, and sampling time affected serum TSH concentrations. • Sampling time was the major factor affecting serum TSH concentrations. Measuring thyroid-stimulating hormone (TSH) is essential for diagnosing and monitoring thyroid diseases. The aim of this study was to evaluate the effect of sex, age, sampling time and season on TSH in a large Chinese population and to determine which factor had the greatest impact on TSH measurement results.

60 APPLIED LIFE SCIENCES↗

Determining the water-cement ratio, cement content, water content and degree of hydration of hardened cement paste: Method development and validation on paste samples

We propose a new method to estimate the initial cement content, water content and free water/cement ratio (w/c) of hardened cement-based materials made with Portland cements that have unknown mixture proportions and degree of hydration. This method first quantifies the composition of the hardened cement paste, i.e. the volumetric fractions of capillary pores, hydration products and unreacted cement, using high-resolution field emission scanning electron microscopy (FE-SEM) in the backscattered electron (BSE) mode and image analysis. From the obtained data and the volumetric increase of solids during cement hydration, we compute the initial free water content and cement content, hence the free w/c ratio. The same method can also be used to calculate the degree of hydration. The proposed method has the advantage that it is quantitative and does not require comparison with calibration graphs or reference samples made with the same materials and cured to the same degree of hydration as the tested sample. This paper reports the development, assumptions and limitations of the proposed method, and preliminary results from Portland cement pastes with a range of w/c ratios (0.25-0.50) and curing ages (3-90 days). We also discuss the extension of the technique to mortars and concretes, and samples made with blended cements.

36 MATERIALS SCIENCE↗

A nonlinear data-driven reduced order model for computational homogenization with physics/pattern-guided sampling

Developing an accurate nonlinear reduced order model from simulation data has been an outstanding research topic for many years. For many physical systems, data collection is very expensive and the optimal data distribution is not known in advance. Thus, maximizing the information gain remains a grand challenge. In a recent paper, Bhattacharjee and Matouš (2016) proposed a manifold-based nonlinear reduced order model for multiscale problems in mechanics of materials. Expanding this work here, we develop a novel sampling strategy based on the physics/pattern-guided data distribution. Our adaptive sampling strategy relies on enrichment of sub-manifolds based on the principal stretches and rotational sensitivity analysis. This novel sampling strategy substantially decreases the number of snapshots needed for accurate reduced order model construction (i.e., ~5 x reduction of snapshots over Bhattacharjee and Matouš (2016)). Moreover, we build the nonlinear manifold using the displacement rather than deformation gradient data. We provide rigorous verification and error assessment. We demonstrate both localization and homogenization of the multiscale solution on a large particulate composite unit cell.

97 MATHEMATICS AND COMPUTING↗

Accelerating Markov Chain Monte Carlo sampling with diffusion models

Global fits of physics models require efficient methods for exploring high-dimensional and/or multimodal posterior functions. We introduce a novel method for accelerating Markov Chain Monte Carlo (MCMC) sampling by pairing a Metropolis-Hastings algorithm with a diffusion model that can draw global samples with the aim of approximating the posterior. We briefly review diffusion models in the context of image synthesis before providing a streamlined diffusion model tailored towards low-dimensional data arrays. We then present our adapted Metropolis-Hastings algorithm which combines local proposals with global proposals taken from a diffusion model that is regularly trained on the samples produced during the MCMC run. Our approach leads to a significant reduction in the number of likelihood evaluations required to obtain an accurate representation of the Bayesian posterior across several analytic functions, as well as for a physical example based on a global fit of parton distribution functions. Our method is extensible to other MCMC techniques, and we briefly compare our method to similar approaches based on normalising flows. A code implementation can be found at https://github.com/NickHunt-Smith/MCMC-diffusion.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Effect of the sample work function on alkali metal dosing induced electronic structure change

Alkali metal dosing (AMD) has been widely used as a way to control doping without chemical substitution. This technique, in combination with angle resolved photoemission spectroscopy (ARPES), often provides an opportunity to observe unexpected phenomena. However, the amount of transferred charge and the corresponding change in the electronic structure vary significantly depending on the material. Here, we report study on the correlation between the sample work function and alkali metal induced electronic structure change for three iron-based superconductors: FeSe, Ba(Fe 0.94 Co 0.06 ) 2 As 2 and NaFeAs which share a similar Fermi surface topology. Electronic structure change upon monolayer of alkali metal dosing and the sample work function were measured by ARPES. In this work, our results show that the degree of electronic structure change is proportional to the difference between the work function of the sample and Mulliken's absolute electronegativity of the dosed alkali metal. This finding provides a possible way to estimate the AMD induced electronic structure change.

36 MATERIALS SCIENCE↗

Resolution of rare earth element interferences in fossil energy by-product samples using sector-field ICP-MS

Here, the supply and price of rare earth elements (REEs) have become a concern to many countries in the world, which has led to renewed interest in exploration and recovery of REEs from secondary or waste sources. Potential high REE waste sources that are of particular interest are coal mining, preparation, combustion, and other fossil energy by-products, including those from natural gas production. In this work, we have examined a set of five solid samples from the treatment of produced and flowback water containing elevated concentrations of barium. In order to confirm the correct concentrations of Eu, we studied these materials using sector field inductively coupled plasma mass spectrometry (SF-ICP-MS), which is capable of resolving species of nearly identical masses, including Eu and BaO. While the use of quadrupole inductively coupled plasma mass spectrometry (Q-ICP-MS) for the REE analysis of most geological sample matrices should pose no problem, the presence of large amounts of Ba, as encountered in water treatment solids from natural gas produced and flowback samples may require SF-ICP-MS for accurate determination of all REEs.

20 FOSSIL-FUELED POWER PLANTS↗

Molybdenum in basalt-hosted seafloor hydrothermal systems: Experimental, theoretical, and field sampling approaches

Here, seafloor hydrothermal vents represent potential sources of Mo and other biologically relevant transition metals to the global ocean, complementing continental runoff. Here, we use a combination of experimental, theoretical, and field-sampling approaches to investigate the behavior of Mo in basalt-hosted seafloor hydrothermal systems to provide insight into the processes controlling Mo concentrations in hydrothermal fluids and to derive estimates of vent fluid Mo concentrations and fluxes. Results of this study demonstrate that reaction fluids generated from 350°C, 500 bar hydrothermal basalt alteration experiments contain 775–801 nmol/kg Mo and are thus comparable to a recently collected time series of natural seafloor vent fluids that contained 200–220 nmol/kg Mo at 302°C and 29–30 nmol/kg at 281–282°C (Evans et al., 2023). Synchrotron-based analyses of experimentally altered basalt produced in this study and additional natural samples of altered oceanic crust originally collected from Pito Deep Rift reveal the presence of Mo-rich particles consistent with trace molybdenite. Comparisons of Mo:Cu ratios in natural vent fluids and near-vent sediment trap samples from Main Endeavour Field indicate that vent fluid Mo is readily incorporated into buoyant plume particles and advected out of the near-vent field, analogous to previous mass balance studies of Cu in this region. Thermodynamic calculations of molybdenite solubility in the context of mineral-buffered hydrothermal fluids and comparisons with natural and experimental hydrothermal fluids suggest that high-temperature vent fluids contain 30–1500 nmol/kg Mo. While a minor component of the modern Mo budget, hydrothermal Mo fluxes are estimated to have constituted 0.3–200× the contemporaneous continental weathering fluxes prior to the ~2.4 Ga ago “Great Oxidation Event” and widespread oxidative continental weathering. Overall, identification of hydrothermal vents as a source of Mo-rich plume particles with potential for dispersal into the wider marine environment has significant implications for hypotheses regarding the co-evolution of Life and Earth’s environments, specifically the form and availability of Mo in anoxic Archean-Eon oceans, where Mo-dependent enzymatic pathways are thought to have emerged and subsequently evolved.

58 GEOSCIENCES↗

Refine your search to explore more results.