Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “REACTOR INSTRUMENTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Strategy for the absolute neutron emission measurement on ITER

Accuracy of 10% is demanded to the absolute fusion measurement on ITER. To achieve this accuracy, a functional combination of several types of neutron measurement subsystem, cross calibration among them, and in situ calibration are needed. Neutron transport calculation shows the suitable calibration source is a DT/DD neutron generator of source strength higher than 10{sup 10} n/s (neutron/second) for DT and 10{sup 8} n/s for DD. It will take eight weeks at the minimum with this source to calibrate flux monitors, profile monitors, and the activation system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tetrafluoroethane (R134a) hydrate formation within variable volume reactor accompanied by evaporation and condensation

Vast size hydrate formation reactors with fast conversion rate are required for the economic implementation of seawater desalination utilizing gas hydrate technology. The commercial target production rate is order of thousand tons of potable water per day per train. Various heat and mass transfer enhancement schemes including agitation, spraying, and bubbling have been examined to maximize the production capacities in scaled up design of hydrate formation reactors. The present experimental study focused on acquiring basic knowledge needed to design variable volume reactors to produce tetrafluoroethane hydrate slurry. Test vessel was composed of main cavity with fixed volume of 140 ml and auxiliary cavity with variable volume of 0 ∼ 64 ml. Temperatures at multiple locations within vessel and pressure were monitored while visual access was made through front window. Alternating evaporation and condensation induced by cyclic volume change provided agitation due to density differences among water and vapor, liquid and hydrate R134a as well as extended interface area, which improved hydrate formation kinetics coupled with latent heat release and absorption. Influences of coolant temperature, piston stroke/speed, and volume change period on hydrate formation kinetics were investigated. Suggestions of reactor design improvement for future experimental study are also made.

42 ENGINEERING↗

Characterization of Fissile Assemblies Using Low-Efficiency Detection Systems

Here, we have investigated the possibility that the amount, chemical form, multiplication, and shape of the fissile material in an assembly can be passively assayed using scintillator detection systems by only measuring the fast neutron pulse height distribution and distribution of time intervals Δt between fast neutrons. We have previously demonstrated that the alpha-ratio can be obtained from the observed pulse height distribution for fast neutrons. In this paper we report that we report that when the distribution of time intervals is plotted as a function of logΔt, the position of the correlated neutron peak is nearly independent of detector efficiency and determines the internal relaxation rate for fast neutrons. If this information is combined with knowledge of the alpha-ratio, then the position of the minimum between the correlated and uncorrelated peaks can be used to rapidly estimate the mass, multiplication, and shape of fissile material. This method does not require a priori knowledge of either the efficiency for neutron detection or the alpha-ratio. Although our method neglects 3-neutron correlations, we have used previously obtained experimental data for metallic and oxide forms of Pu to demonstrate that our method yields good estimates for multiplications as large as 2, and that the only constraint on detector efficiency/observation time is that a peak in the interval time distribution due to correlated neutrons is visible.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

OECD MCCI Project: Small-Scale Water Ingression and Crust Strength Tests (SSWICS), SSWICS-12 Design Report

The Melt Attack and Coolability Experiments (MACE) program at Argonne National Laboratory addressed the issue of the ability of water to cool and thermally stabilize a molten core/concrete interaction (MCCI) when the reactants are flooded from above. These experiments provided unique, and for the most part repeatable, indications of heat transfer mechanisms that could provide long term debris cooling. The tests provided data regarding the nature of corium interactions with concrete, the heat transfer rates from the melt to the overlying water pool, and the role of noncondensable gases in the mixing processes that contribute to melt quenching. However, due to the integral nature of the tests, several questions regarding the crust freezing behavior could not be adequately resolved. SSWICS-12 will be similar in many respects to the preceding tests, e.g., fully oxidized melt with concrete constituents, 30 cm melt diameter, inert basemat, quench at 1 bar, and condensation of steam with collection of the condensate to measure gross cooling rate. The major departure from previous tests is the addition of water injection nozzles cast within the basemat. Each injection line will have its own water supply and flow rate sensor. The melt will be partitioned into quadrants using metal plates to create, in effect, four independent and simultaneous injection tests. Each nozzle is to have a different driving head. The purpose of this experiment is to determine the following: 1) the minimum driving head required to ensure water injection into the melt, 2) the water flow rate to each nozzle, 3) the cooling rate of each melt quadrant, 4) the effect of water injection on crust morphology. The melt depth will be 30 cm (versus 15 cm for all previous tests) so that it is closer to the 20-30 cm depth expected in a plant. The remainder of this report describes the test apparatus, instrumentation, test procedure, and data reduction.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development and Deployment Assessment of a Melt-Down Proof Modular Micro Reactor (MDP-MMR)

The objective of this project is to perform feasibility assessment and technology gap analysis and establish a development roadmap for an innovative and highly compact Micro Modular Reactor (MMR) concept that integrates power production, power conversion and electricity generation in a single unit. The MMR is envisioned to use fully ceramic micro-encapsulated (FCM) fuel, a particularly robust form of TRISO fuel, and to be gas-cooled (e.g., He or CO 2 ) and capable of generating power in the range of 10 to 40 MW-thermal. It is designed to be absolutely melt-down proof (MDP) under all circumstances including complete loss of coolant scenarios with no possible release of radioactive material, to be factory produced, to have a cycle length of greater than 20 years, and to be highly proliferation resistant. In addition, it will be transportable, retrievable and suitable for use in remote areas. As such, the MDP-MMR will represent a versatile reactor concept that is suitable for use in various applications including electricity generation, process heat utilization and propulsion.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ICP-MS For Analysis of Lithium Isotopic Ratios in Materials Highly Enriched in 7 Li (CRADA 626) Final Report

The intent of this project was to determine appropriate methodologies for analysis of lithium isotopes for 1) quasi-online monitoring of isotope separations, and 2) high-precision characterization of end-products, including lithium fluoride and lithium-beryllium fluoride (FLiBe). Traditionally, isotopic analysis requires the use of expensive, sophisticated instrumentation with often relatively long analytical timelines. We determined that the use of cheaper, smaller, and easier-to-operate instruments are sufficient for rapid analysis of lithium isotopes to monitor isotope separation efficiencies. In addition, we found that the analytical precision afforded by these lower-cost instruments is comparable to the more sophisticated (i.e., more expensive) instrumentation when the isotopic composition of lithium becomes highly depleted in 6Li. This finding will ultimately help lower costs of manufacturing of depleted lithium that is required for operation of certain designs of Generation IV nuclear reactors.

07 ISOTOPE AND RADIATION SOURCES↗

Guidance for Human-system Interfaces to Automatic Systems

Automation is ubiquitous in modern complex systems, and commercial nuclear- power plants are no exception. Automation is applied to a wide range of functions, including monitoring and detection, situation assessment, response planning, and response implementation. Automation has become a 'team player' supporting personnel in nearly all aspects of system operation. In light of its increasing use and importance in new- and future-plants, guidance is needed to conduct safety reviews of the operator's interface with automation. The objective of this research was to develop such guidance. We first characterized the important HFE aspects of automation, including six dimensions: Levels, functions, processes, modes, flexibility, and reliability. Next, we reviewed literature on the effects of all of these aspects of automation on human performance, and on the design of human-system interfaces (HSIs). Then, we used this technical basis established from the literature to identify general principles for human-automation interaction and to develop review guidelines. The guidelines consist of the following seven topics: Automation displays, interaction and control, automation modes, automation levels, adaptive automation, error tolerance and failure management, and HSI integration.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Center for Advanced Modeling and Simulation Intern

Some interns just copy papers and seal envelopes. Not at INL! Check out how Vanessa Gertman, an INL intern working at the Center for Advanced Modeling and Simulation, spent her summer working with some intense visualization software. Lots more content like this is available at INL's facebook page http://www.facebook.com/idahonationallaboratory.

47 OTHER INSTRUMENTATION↗

Log-N/Period Sensitivity Analysis

The Log-N/Period system utilizes a compensated ion chamber to measure neutron radiation in the reactor core. This analysis focuses on determining a more accurate value for the sensitivity of the installed compensated ion chambers for the Log-N/Period system at the ATR. Using calibration procedures a formula for indirectly calculating the sensitivity of the chambers was derived. Using historical data from approximately ten reactor cycles a new average sensitivity for both channels of the Log-N/Period system was determined.

42 ENGINEERING↗

Modeling Predictive Maintenance for NuScale’s Condensate and Feedwater System Using EMRALD

Event Modeling Risk Assessment using Linked Diagrams (EMRALD) is used to model of NuScale’s feedwater and condenser system to capture component degradation and repairing process. To model the reliability of the components, a three-stage failure rate is used contrary to a constant rate leading to component failure. Results from EMRALD will be used to compare different maintenance strategies to reduce system downtime. The outcome of the project will assist in maximizing remaining useful life of the overall system and increasing the availability and revenue of the plant.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Establishing a Cyber Security Culture for the Nuclear Industry

This paper explores the development of a Cyber Security Culture that deploys the appropriate technological and Human Performance tools using the key tenets of INPO's Nuclear Safety Culture program as a basis. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Space- and time-resolved resistive measurements of liquid metal wall thickness

In a fusion reactor internally coated with liquid metal, it will be important to diagnose the thickness of the liquid at various locations in the vessel, as a function of time, and possibly respond to counteract undesired bulging or depletion. The electrical conductance between electrodes immersed in the liquid metal can be used as a simple proxy for the local thickness. Here a matrix of electrodes is shown to provide spatially and temporally resolved measurements of liquid metal thickness in the absence of plasma. First a theory is developed for m × n electrodes, and then it is experimentally demonstrated for 3 × 1 electrodes, as the liquid stands still or is agitated by means of a shaker. The experiments were carried out with Galinstan, but are easily extended to lithium or other liquid metals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of plutonium in spent nuclear fuel by self-induced x-ray fluorescence

Direct measurement of the plutonium content in spent nuclear fuel is a challenging problem in non-destructive assay. The very high gamma-ray flux from fission product isotopes overwhelms the weaker gamma-ray emissions from plutonium and uranium, making passive gamma-ray measurements impossible. However, the intense fission product radiation is effective at exciting plutonium and uranium atoms, resulting in subsequent fluorescence X-ray emission. K-shell X-rays in the 100 keV energy range can escape the fuel and cladding, providing a direct signal from uranium and plutonium that can be measured with a standard germanium detector. The measured plutonium to uranium elemental ratio can be used to compute the plutonium content of the fuel. The technique can potentially provide a passive, non-destructive assay tool for determining plutonium content in spent fuel. In this paper, we discuss recent non-destructive measurements of plutonium X-ray fluorescence (XRF) signatures from pressurized water reactor spent fuel rods. We also discuss how emerging new technologies, like very high energy resolution microcalorimeter detectors, might be applied to XRF measurements.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Design and installation of a ferromagnetic wall in tokamak geometry

Low-activation ferritic steels are leading material candidates for use in next-generation fusion development experiments such as a prospective component test facility and DEMO power reactor. Understanding the interaction of plasmas with a ferromagnetic wall will provide crucial physics for these facilities. In order to study ferromagnetic effects in toroidal geometry, a ferritic wall upgrade was designed and installed in the High Beta Tokamak–Extended Pulse (HBT-EP). Several material options were investigated based on conductivity, magnetic permeability, vacuum compatibility, and other criteria, and the material of choice (high-cobalt steel) is characterized. Installation was accomplished quickly, with minimal impact on existing diagnostics and overall machine performance, and initial results demonstrate the effects of the ferritic wall on plasma stability.

42 ENGINEERING↗

High Temperature Irradiation-Resistant Thermocouple Performance Improvements

Traditional methods for measuring temperature in-pile degrade at temperatures above 1100 ºC. To address this instrumentation need, the Idaho National Laboratory (INL) developed and evaluated the performance of a high temperature irradiation-resistant thermocouple (HTIR-TC) that contains alloys of molybdenum and niobium. Data from high temperature (up to 1500 ºC) long duration (up to 4000 hours) tests and on-going irradiations at INL’s Advanced Test Reactor demonstrate the superiority of these sensors to commercially-available thermocouples. However, several options have been identified that could further enhance their reliability, reduce their production costs, and allow their use in a wider range of operating conditions. This paper presents results from on-going Idaho National Laboratory (INL)/University of Idaho (UI) efforts to investigate options to improve HTIR-TC ductility, reliability, and resolution by investigating specially-formulated alloys of molybdenum and niobium and alternate diameter thermoelements (wires). In addition, on-going efforts to evaluate alternate fabrication approaches, such as drawn and loose assembly techniques will be discussed. Efforts to reduce HTIR-TC fabrication costs, such as the use of less expensive extension cable will also be presented. Finally, customized HTIR-TC designs developed for specific customer needs will be summarized to emphasize the varied conditions under which these sensors may be used.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

νSTORM - Neutrinos from STORed Muons: Letter of Intent to the Fermilab Physics Advisory Committee

The results of LSND and MiniBooNE, along with the recent papers on a possible reactor neutrino flux anomaly give tantalizing hints of new physics. Models beyond the neutrino-SM have been developed to explain these results and involve one or more additional neutrinos that are non-interacting or 'sterile.' Neutrino beams produced from the decay of muons in a racetrack-like decay ring provide a powerful way to study this potential new physics. In this Letter of Intent, we describe a facility, νSTORM, 'Neutrinos from STORed Muons,' and an appropriate far detector for neutrino oscillation searches at short baseline. We present sensitivity plots that indicated that this experimental approach can provide over 10 sigma confirmation or rejection of the LSND/MinBooNE results. In addition we indicate how the facility can be used to make precision neutrino interaction cross section measurements important to the next generation of long-baseline neutrino oscillation experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A decision support system prototype including human factors based on the TOGA meta-theory approach

The human contribution to the risk of operation of complex technological systems is often not negligible and sometimes tends to become significant, as shown by many reports on incidents and accidents occurred in the past inside Nuclear Power Plants (NPPs). An error of a human operator of a NPP can derive by both omission and commission. For instance, complex commission errors can also lead to significant catastrophic technological accidents, as for the case of the Three Mile Island accident. Typically, the problem is analyzed by focusing on the single event chain that has provoked the incident or accident. What is needed is a general framework able to include as many parameters as possible, i.e. both technological and human factors. Such a general model could allow to envisage an omission or commission error before it can happen or, alternatively, suggest preferred actions to do in order to take countermeasures to neutralize the effect of the error before it becomes critical. In this paper, a preliminary Decision Support System (DSS) based on the so-called (-) TOGA meta-theory approach is presented. The application of such a theory to the management of nuclear power plants has been presented in the previous ICAPP 2011. Here, a human factor simulator prototype is proposed in order to include the effect of human errors in the decision path. The DSS has been developed using a TRIGA research reactor as reference plant, and implemented using the LabVIEW programming environment and the Finite State Machine (FSM) model The proposed DSS shows how to apply the Universal Reasoning Paradigm (URP) and the Universal Management Paradigm (UMP) to a real plant context. The DSS receives inputs from instrumentation data and gives as output a suggested decision. It is obtained as the result of an internal elaborating process based on a performance function. The latter, describes the degree of satisfaction and efficiency, which are dependent on the level of responsibility related to each professional role. As an application, we present the simulation of the discussed error, e.g. the unchecked extraction of the control rods during a power variation maneuver and we show how the effect of human errors can affect the performance function, giving rise to different countermeasures which could call different operator figures into play, potentially not envisaged in the standard procedure. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Refine your search to explore more results.