Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Protection & Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Control of extended high-voltage electric discharges in atmospheric air by UV KrF-laser radiation

Experiments in the commutation of extended ({approx}1-m long) high-voltage (up to 390 kV) electric discharges were carried out with the aid of 100-ns long UV pulses of the GARPUN KrF laser, in which we demonstrated a one-and-a-half-fold lengthening of the discharge gap broken down in the presence of laser illumination. Total control of discharge trajectory along the direction of the laser beam was observed for a radiation energy of {approx}300 mJ (the corresponding intensity I = 5x10{sup 8} W cm{sup -2} and its attendant initial electron density Ne {approx} 10{sup 11} cm{sup -3}) and partial control for an energy of 40 mJ (I = 7x10{sup 7} W cm{sup -2}, Ne {approx} 8x10{sup 9} cm{sup -3}) with a 100% probability of breakdown. We discuss the advantages of employing a UV laser for active lightning protection in comparison with IR lasers and ultrashort-pulse laser systems. (interaction of laser radiation with matter)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The feasibility of a piecewise-linear dynamic bowtie filter

Purpose: The prepatient attenuator (or 'bowtie filter') in CT is used to modulate the flux as a function of fan angle of the x-ray beam incident on the patient. Traditional, static bowtie filters are tailored only for very generic scans and for the average patient. The authors propose a design for a dynamic bowtie that can produce a time-dependent piecewise-linear attenuation profile. This dynamic bowtie may reduce dynamic range, dose or scatter, but in this work they focus on its ability to reduce dynamic range, which may be particularly important for systems employing photon-counting detectors. Methods: The dynamic bowtie is composed of a set of triangular wedges. Each wedge is independently moved in order to produce a time-dependent piecewise-linear attenuation profile. Simulations of the bowtie are conducted to estimate the dynamic range reduction in six clinical datasets. The control of the dynamic bowtie is determined by solving a convex optimization problem, and the dose is estimated using Monte Carlo techniques. Beam hardening artifacts are also simulated. Results: The dynamic range is reduced by factors ranging from 2.4 to 27 depending on the part of the body studied. With a dynamic range minimization objective, the dose to the patient can be reduced from 6% to 33% while maintaining peak image noise. Further reduction in dose may be possible with a specific dose reduction objective. Beam hardening artifacts are suppressed with a two-pass algorithm. Conclusions: A dynamic bowtie producing a time-dependent, piecewise-linear attenuation profile is possible and can be used to modulate the flux of the scanner to the imaging task. Initial simulations show a large reduction in dynamic range. Several other applications are possible.

60 APPLIED LIFE SCIENCES↗

Protection against dexamethasone-induced muscle atrophy is related to modulation by testosterone of FOXO1 and PGC-1{alpha}

Research highlights: {yields} In rat gastrocnemius muscle, dexamethasone reduced PGC-1{alpha} cellular and nuclear levels without altering mRNA levels for this factor. {yields} Dexamethasone reduced phosphorylating of p38 MAPK, which stabilizes PGC-1{alpha} and promotes its nuclear entry. {yields} Co-administration of testosterone with dexamethasone increased cellular and nuclear levels of PGC-1{alpha} protein without changing its mRNA levels. {yields} Co-administration of testosterone restored p38 MAPK levels to those of controls. -- Abstract: Glucocorticoid-induced muscle atrophy results from muscle protein catabolism and reduced protein synthesis, associated with increased expression of two muscle-specific ubiquitin ligases (MAFbx and MuRF1), and of two inhibitors of protein synthesis, REDD1 and 4EBP1. MAFbx, MuRF1, REDD1 and 4EBP1 are up-regulated by the transcription factors FOXO1 and FOXO3A. The transcriptional co-activator PGC-1{alpha} has been shown to attenuate many forms of muscle atrophy and to repress FOXO3A-mediated transcription of atrophy-specific genes. Dexamethasone-induced muscle atrophy can be prevented by testosterone, which blocks up-regulation by dexamethasone of FOXO1. Here, an animal model of dexamethasone-induced muscle atrophy was used to further characterize effects of testosterone to abrogate adverse actions of dexamethasone on FOXO1 levels and nuclear localization, and to determine how these agents affect PGC-1{alpha}, and its upstream activators, p38 MAPK and AMPK. In rat gastrocnemius muscle, testosterone blunted the dexamethasone-mediated increase in levels of FOXO1 mRNA, and FOXO1 total and nuclear protein. Dexamethasone reduced total and nuclear PGC-1{alpha} protein levels in the gastrocnemius; co-administration of testosterone with dexamethasone increased total and nuclear PGC-1{alpha} levels above those present in untreated controls. Testosterone blocked dexamethasone-induced decreases in activity of p38 MAPK in the gastrocnemius muscle. Regulation of FOXO1, PGC-1{alpha} and p38 MAPK by testosterone may represent a novel mechanism by which this agent protects against dexamethasone-induced muscle atrophy.

60 APPLIED LIFE SCIENCES↗

MO-AB-207-02: ACR Update in MR

A goal of an imaging accreditation program is to ensure adequate image quality, verify appropriate staff qualifications, and to assure patient and personnel safety. Currently, more than 35,000 facilities in 10 modalities have been accredited by the American College of Radiology (ACR), making the ACR program one of the most prolific accreditation options in the U.S. In addition, ACR is one of the accepted accreditations required by some state laws, CMS/MIPPA insurance and others. Familiarity with the ACR accreditation process is therefore essential to clinical diagnostic medical physicists. Maintaining sufficient knowledge of the ACR program must include keeping up-to-date as the various modality requirements are refined to better serve the goals of the program and to accommodate newer technologies and practices. This session consists of presentations from authorities in four ACR accreditation modality programs, including magnetic resonance imaging, computed tomography, nuclear medicine, and mammography. Each speaker will discuss the general components of the modality program and address any recent changes to the requirements. Learning Objectives: To understand the requirements of the ACR MR Accreditation program. The discussion will include accreditation of whole-body general purpose magnets, dedicated extremity systems well as breast MRI accreditation. Anticipated updates to the ACR MRI Quality Control Manual will also be reviewed. To understand the requirements of the ACR CT accreditation program, including updates to the QC manual as well as updates through the FAQ process. To understand the requirements of the ACR nuclear medicine accreditation program, and the role of the physicist in annual equipment surveys and the set up and supervision of the routine QC program. To understand the current ACR MAP Accreditation requirement and present the concepts and structure of the forthcoming ACR Digital Mammography QC Manual and Program.

60 APPLIED LIFE SCIENCES↗

High performance III-V photoelectrodes for solar water splitting via synergistically tailored structure and stoichiometry

Abstract Catalytic interface of semiconductor photoelectrodes is critical for high-performance photoelectrochemical solar water splitting because of its multiple roles in light absorption, electrocatalysis, and corrosion protection. Nevertheless, simultaneously optimizing each of these processes represents a materials conundrum owing to conflicting requirements of materials attributes at the electrode surface. Here we show an approach that can circumvent these challenges by collaboratively exploiting corrosion-resistant surface stoichiometry and structurally-tailored reactive interface. Nanoporous, density-graded surface of ‘black’ gallium indium phosphide (GaInP 2 ), when combined with ammonium-sulfide-based surface passivation, effectively reduces reflection and surface recombination of photogenerated carriers for high efficiency photocatalysis in the hydrogen evolution half-reaction, but also augments electrochemical durability with lifetime over 124 h via strongly suppressed kinetics of corrosion. Such synergistic control of stoichiometry and structure at the reactive interface provides a practical pathway to concurrently enhance efficiency and durability of semiconductor photoelectrodes without solely relying on the development of new protective materials.

14 SOLAR ENERGY↗

Hanford External Dosimetry Technical Basis Manual PNL-MA-842

The Hanford External Dosimetry Technical Basis Manual PNL-MA-842 documents the design and implementation of the external dosimetry system used at the U.S. Department of Energy (DOE) Hanford site. The manual describes the dosimeter design, processing protocols, dose calculation methodology, radiation fields encountered, dosimeter response characteristics, limitations of dosimeter design under field conditions, and makes recommendations for effective use of the dosimeters in the field. The manual describes the technical basis for the dosimetry system in a manner intended to help ensure defensibility of the dose of record at Hanford and to demonstrate compliance with requirements of 10 CFR 835, the DOE Laboratory Accreditation Program, the DOE Richland Operations Office, DOE Office of River Protection, DOE Pacific Northwest Office of Science, and Hanford’s DOE contractors. The dosimetry system is operated by the Pacific Northwest National Laboratory (PNNL) Hanford External Dosimetry Program which provides dosimetry services to PNNL and all Hanford contractors. The primary users of this manual are DOE and DOE contractors at Hanford using the dosimetry services of PNNL. Development and maintenance of this manual is funded directly by DOE and DOE contractors. Its contents have been reviewed and approved by DOE and DOE contractors at Hanford through the Hanford Personnel Dosimetry Advisory Committee which is chartered and chaired by DOE-RL and serves as means of coordinating dosimetry practices across contractors at Hanford. This manual was established in 1996. Since its inception, it has been revised many times and maintained by PNNL as a controlled document with controlled distribution. The first revision to be released through PNNL’s Electronic Records & Information Capture Architecture database was designated Revision 0. Revision numbers that are whole numbers reflect major revisions typically involving significant changes to all chapters in the document. Revision numbers that include a decimal fraction reflect minor revisions, usually restricted to selected chapters or selected pages in the document. Maintenance and distribution of controlled hard copies of the manual by PNNL was discontinued beginning with Revision 0.2.

61 RADIATION PROTECTION AND DOSIMETRY↗

Hypoxia in the Northern Gulf of Mexico

Since 1985, scientists have been documenting a hypoxic zone in the Gulf of Mexico each year. The hypoxic zone, an area of low dissolved oxygen that cannot support marine life, generally manifests itself in the spring. Since marine species either die or flee the hypoxic zone, the spread of hypoxia reduces the available habitat for marine species, which are important for the ecosystem as well as commercial and recreational fishing in the Gulf. Since 2001, the hypoxic zone has averaged 16,500 km{sup 2} during its peak summer months, an area slightly larger than the state of Connecticut, and ranged from a low of 8,500 km{sup 2} to a high of 22,000 km{sup 2}. To address the hypoxia problem, the Mississippi River/Gulf of Mexico Watershed Nutrient Task Force (or Task Force) was formed to bring together representatives from federal agencies, states, and tribes to consider options for responding to hypoxia. The Task Force asked the White House Office of Science and Technology Policy to conduct a scientific assessment of the causes and consequences of Gulf hypoxia through its Committee on Environment and Natural Resources (CENR). In 2000 the CENR completed An Integrated Assessment: Hypoxia in the Northern Gulf of Mexico (or Integrated Assessment), which formed the scientific basis for the Task Force's Action Plan for Reducing, Mitigating, and Controlling Hypoxia in the Northern Gulf of Mexico (Action Plan, 2001). In its Action Plan, the Task Force pledged to implement ten management actions and to assess progress every 5 years. This reassessment would address the nutrient load reductions achieved, the responses of the hypoxic zone and associated water quality and habitat conditions, and economic and social effects. The Task Force began its reassessment in 2005. In 2006 as part of the reassessment, USEPA's Office of Water, on behalf of the Task Force, requested that the U.S. Environmental Protection Agency (USEPA) Science Advisory Board (SAB) convene an independent panel to evaluate the state-of-the-science regarding hypoxia in the Northern Gulf of Mexico and potential nutrient mitigation and control options in the Mississippi-Atchafalaya River basin (MARB). The Task Force was particularly interested in scientific advances since the Integrated Assessment and posed questions in three areas: characterization of hypoxia; nutrient fate, transport and sources; and the scientific basis for goals and management options. The Hypoxia Study Group began its deliberations in September of 2006 and completed its report in August of 2007 while operating under the 'sunshine' requirements of the Federal Advisory Committee Act, which include providing public access to advisory meetings and opportunities for public comment. This Executive Summary summarizes the Hypoxia Study Group's major findings and recommendations.

54 ENVIRONMENTAL SCIENCES↗

A controlled statistical study to assess measurement variability as a function of test object position and configuration for automated surveillance in a multicenter longitudinal COPD study (SPIROMICS)

Purpose: A test object (phantom) is an important tool to evaluate comparability and stability of CT scanners used in multicenter and longitudinal studies. However, there are many sources of error that can interfere with the test object-derived quantitative measurements. Here the authors investigated three major possible sources of operator error in the use of a test object employed to assess pulmonary density-related as well as airway-related metrics. Methods: Two kinds of experiments were carried out to assess measurement variability caused by imperfect scanning status. The first one consisted of three experiments. A COPDGene test object was scanned using a dual source multidetector computed tomographic scanner (Siemens Somatom Flash) with the Subpopulations and Intermediate Outcome Measures in COPD Study (SPIROMICS) inspiration protocol (120 kV, 110 mAs, pitch = 1, slice thickness = 0.75 mm, slice spacing = 0.5 mm) to evaluate the effects of tilt angle, water bottle offset, and air bubble size. After analysis of these results, a guideline was reached in order to achieve more reliable results for this test object. Next the authors applied the above findings to 2272 test object scans collected over 4 years as part of the SPIROMICS study. The authors compared changes of the data consistency before and after excluding the scans that failed to pass the guideline. Results: This study established the following limits for the test object: tilt index ≤0.3, water bottle offset limits of [−6.6 mm, 7.4 mm], and no air bubble within the water bottle, where tilt index is a measure incorporating two tilt angles around x- and y-axis. With 95% confidence, the density measurement variation for all five interested materials in the test object (acrylic, water, lung, inside air, and outside air) resulting from all three error sources can be limited to ±0.9 HU (summed in quadrature), when all the requirements are satisfied. The authors applied these criteria to 2272 SPIROMICS scans and demonstrated a significant reduction in measurement variation associated with the test object. Conclusions: Three operator errors were identified which significantly affected the usability of the acquired scan images of the test object used for monitoring scanner stability in a multicenter study. The authors’ results demonstrated that at the time of test object scan receipt at a radiology core laboratory, quality control procedures should include an assessment of tilt index, water bottle offset, and air bubble size within the water bottle. Application of this methodology to 2272 SPIROMICS scans indicated that their findings were not limited to the scanner make and model used for the initial test but was generalizable to both Siemens and GE scanners which comprise the scanner types used within the SPIROMICS study.

60 APPLIED LIFE SCIENCES↗

Results of The Excreta Bioassay Quality Control Program For April 1, 2008 through March 31, 2009

A total of 62 urine samples and 6 spiked fecal samples were submitted during the report period (April 1, 2008 through March 31, 2009) to General Engineering Laboratories, South Carolina by the Hanford Internal Dosimetry Program (IDP) to check the accuracy, precision, and detection levels of their analyses. Urine analyses for Sr, 238Pu, 239Pu, 241Am, 243Am 235U, 238U, elemental uranium and fecal analyses for 241Am, 238Pu and 239Pu were tested this year. The number of QC urine samples submitted during the report period represented 1.3% of the total samples submitted. In addition to the samples provided by IDP, GEL was also required to conduct their own QC program, and submit the results of analyses to IDP. About 34% of the analyses processed by GEL during the third year of this contract were quality control samples. GEL tested the performance of 21 radioisotopes, all of which met or exceeded the specifications in the Statement of Work within statistical uncertainty. IDP concluded that GEL was performing well for all analyses tested, and concerns identified earlier were satisfactorily resolved (see section on Follow-up on Concerns During the Fourth Contract Year).

61 RADIATION PROTECTION AND DOSIMETRY↗

A path to stable low-torque plasma operation in ITER with test blanket modules

New experiments in the low-torque ITER Q = 10 scenario on DIII-D demonstrate that n = 1 magnetic fields from a single row of ex-vessel control coils enable operation at ITER performance metrics in the presence of applied non-axisymmetric magnetic fields from a test blanket module (TBM) mock-up coil. With n = 1 compensation, operation below the ITER-equivalent injected torque is successful at three times the ITER equivalent toroidal magnetic field ripple for a pair of TBMs in one equatorial port, whereas the uncompensated TBM field leads to rotation collapse, loss of H-mode and plasma current disruption. In companion experiments at high plasma beta, where the n = 1 plasma response is enhanced, uncorrected TBM fields degrade energy confinement and the plasma angular momentum while increasing fast ion losses; however, disruptions are not routinely encountered owing to increased levels of injected neutral beam torque. In this regime, n = 1 field compensation leads to recovery of a dominant fraction of the TBM-induced plasma pressure and rotation degradation, and an 80% reduction in the heat load to the first wall. These results show that the n = 1 plasma response plays a dominant role in determining plasma stability, and that n = 1 field compensation alone not only recovers most of the impact on plasma performance of the TBM, but also protects the first wall from potentially damaging heat flux. Despite these benefits, plasma rotation braking from the TBM fields cannot be fully recovered using standard error field control. Lastly, given the uncertainty in extrapolation of these results to the ITER configuration, it is prudent to design the TBMs with as low a ferromagnetic mass as possible without jeopardizing the TBM mission.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Deactivation and Demolition (D and D) of the Toxic Substance Control Act (TSCA) Incinerator Oak Ridge, Tennessee - 19184

UCOR, an AECOM-led partnership with Jacobs, manages the cleanup of the 2,200-acre East Tennessee Technology Park for its client, the U.S. Department of Energy (DOE), in Oak Ridge, Tennessee. The site was contaminated with radioactive, hazardous and industrial wastes generated by more than 40 years of national defense and energy missions. In 1989, the U.S. Environmental Protection Agency (EPA) added the Oak Ridge Reservation to the National Priorities List of sites and facilities that pose a sufficient threat to human health or the environment to warrant cleanup. The U.S. Department of Energy is cleaning up the Oak Ridge Reservation under a Federal Facility Agreement with the EPA and the Tennessee Department of Environment and Conservation. Many types of waste have been managed and disposed as part of the multi-decade cleanup effort. One unique facility, the Toxic Substance Control Act (TSCA) Incinerator, was constructed at the Department of Energy's Est Tennessee Technology Park (ETTP) in Oak Ridge, Tennessee. The Incinerator was constructed in the mid-1980's and underwent a series of test burns and readiness reviews to obtain the necessary environmental permits and operating approvals from state and federal regulatory agencies. With these in place, the incinerator began routine operations in 1991. It was designed and permitted for receiving, sorting, storing, preparing, and thermally destroying low-level radioactive and RCRA mixed waste contaminated with PCBs. The incinerator was named after a law passed in 1976 that provides the U.S. Environmental Protection Agency with authority to require reporting, record-keeping, testing, and restrictions relating to chemical substances and/or mixtures. During its operating lifetime, the one-of-a-kind thermal treatment facility burned materials regulated under TSCA and the Resource Conservation and Recovery Act (RCRA), most notably radiologically-contaminated polychlorinated biphenyls (PCBs). The TSCA Incinerator met or exceeded environmental regulations and DOE requirements for the treatment of these types of wastes. After more than 18 years of operation and more than 35 million pounds of waste safely incinerated, the TSCA Incinerator shut down operations on December 2, 2009. The TSCA Incinerator has been called a national resource for DOE sites from coast to coast. As the only U.S. facility permitted to incinerate specialized types of wastes, it not only accepted material from the Oak Ridge Reservation but also other facilities across the nationwide DOE complex. Over the years, a dynamic team of hard working and talented people operated and maintained the facility under the most stringent environmental permits and site requirements. The facility has played a key role in the treatment of radioactive PCB and hazardous wastes (mixed wastes) from the Oak Ridge Reservation, as well as from other facilities across the DOE complex. Through its support to over 20 sites in the DOE complex, environmental waste from past and ongoing operations has been safely and permanently treated. In the years since it was shut down, deactivation workers have been preparing TSCA for demolition. This work scope included triple cleaning, rinsing of all production equipment and tanks to RCRA clean criteria, filling sumps, encapsulating PCB and radioactive contamination, removal of universal waste (asbestos. lead and mercury), draining and disposal of residual water in tanks and transfer piping, and removing and disposing of carbon vessels, which were part of the water management system. In 2018, the facility was successfully deactivated and demolished, permanently removing one of the most unique facilities in the DOE complex. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

MO-DE-BRA-01: Flipped Physics Courses Within a Radiologic Technologist Program: Video Production and Long Term Outcomes

Purpose: To determine if the flipped class format has an effect on examination results for a radiologic technologist (RT) program and discuss benefits from creating video resources. Methods: From 2001–2015, students had taken both a radiological physics and quality control (QC) class as a part of their didactic training. In 2005/2006, the creation of videos of didactic lectures and QC test demonstrations allowed for a flip where content was studied at home while exercises and reviews were done in-class. Final examinations were retrospectively reviewed from this timeframe. 12 multiple choice physics questions (MCP) and 5 short answer QC questions (SAQC) were common to pre and post flip exams. The RT program’s ARRT exam scores were also obtained and compared to national averages. Results: In total, 36 lecture videos and 65 quality control videos were created for the flipped content. Data was ∼2.4GB and distributed to students via USB or CD media. For MCP questions, scores improved by 7.9% with the flipped format and significance (Student’s t-test, p<0.05) was found for 3 of the 12 questions. SAQC questions showed improvement by 14.6% and significance was found for 2 of the 5 questions. Student enrollment increased from ∼14 (2001–2004) to ∼23 students (2005–15). Content was continuously added post-flip due to the efficiency of delivery. The QC class in 2003 covered 45 test setups in-class while 65 were covered with video segments in 2014. Flipped materials are currently being repurposed. In 2015, this video content was restructured into an ARRT exam review guide and in 2016, the content was reorganized for fluoroscopy training for physicians. Conclusion: We believe that flipped classes can improve efficiency of content delivery and improve student performance even with an increase in class size. This format allows for flexibility in learning as well as re-use in multiple applications.

07 ISOTOPE AND RADIATION SOURCES↗

On the Limits of EM Based Detection of Control Logic Injection Attacks In Noisy Environments

The difficulty in applying traditional security mechanisms in Industrial Control System (ICS) environments makes a large portion of these mission-critical assets vulnerable to cyber attacks. Therefore, there is a dire need for the development of novel security mechanisms specifically designed to protect such critical systems. Recently a lot of attention has been given to mechanisms that exploit the EM emanations of devices for defense purposes. Such practices may lead to the development of robust external and non-intrusive anomaly detection systems. Nevertheless, the majority of current work in the area neglects to consider the implications of real-life environments, particularly environmental noise. In this work, we explore the limits of EM-based anomaly detection towards identifying injection attacks in control logic software in noisy environments. Our study conducted upon both synthetically generated and real signals identified that indeed environmental noise might significantly degrade the accuracy of the anomaly detection process. Experiments done upon synthetic data indicated that assuming that signals are captured with high sampling rates, even minor code injections can be detected with above-90% accuracy in noisy environments where SNR is up to -2dB. This is true even if naive detection methods are considered. Moreover, experiments done using a real-life testbed attest that even single-instruction injections can be detected with near-perfect accuracy in relatively clean environments. Finally, noise-elimination techniques can drastically improve the reliability of the detection mechanism even in noisy environments.

97 MATHEMATICS AND COMPUTING↗

The circulating immunoglobulins negatively impact on the parasite clearance in the liver of Leishmania donovani-infected mice via dampening ROS activity

Highlights: • Mice with the absence of circulating immunoglobulins are resistant to Leishmania donovani infection. • The clearance of parasites in liver of these mice occurs from the early stage of infection. • This rapid clearance is independent of interferon gamma. • Reactive oxygen species pathway is involved in this rapid clearance. • Circulating immunoglobulins dampens reactive oxygen species pathway in the liver of Leishmania donovani-infected mice. Visceral leishmaniasis, the most severe form of leishmaniasis, is caused by Leishmania donovani and L. infantum. Immunity to Leishmania infection has been shown to depend on the development of Th1 cells; however, the roles of B cells and antibodies during infection remain unclear. In the present study, we showed that AID and μs double-deficient mice (DKO), which have B cells but not circulating immunoglobulins (cIgs), became resistant to L. donovani infection, whereas μs or AID single-deficient mice did not. This resistance in DKO mice occurred in the liver from an early stage of the infection. The depletion of IFN-γ did not affect the rapid reduction of parasite burden, whereas NADPH oxidases was up-regulated in the livers of infected DKO mice. The inhibition of the reactive oxygen species pathway in vivo by apocynin, a NADPH oxidase inhibitor, resulted in a significant increase in the parasite burden in DKO mice. These results indicate that a circulating Ig deficiency induces a protective response against L. donovani infection by elevating IFN-γ-independent NADPH oxidase activity, and also that cIgs play a regulatory role in controlling L. donovani infection in mice.

60 APPLIED LIFE SCIENCES↗

SEA screening of voluntary climate change plans: A story of non-compliant discretion

Screening within Strategic Environmental Assessment (SEA) is the first critical stage involving considerations on whether an assessment is carried out or not. Although legislation and guidance offer practitioners a legal and logical approach to the screening process, it is inevitable that discretionary judgement takes place and will impact on the screening decision. This article examines the results of discretion involved in screening of climate change plans (CCPs) in a Danish context. These years voluntary CCPs are developed as a response to the global and local emergence of both mitigation and adaptation, and the voluntary commitment by the local authorities is an indication of an emerging norm of climate change as an important issue. This article takes its point of departure in the observation that SEA is not undertaken for these voluntary CCPs. The critical analysis of this phenomenon rests upon a documentary study of Danish CCPs, interviews with a lawyer and ministerial key person and informal discussions between researchers, practitioners and lawyers on whether climate change plans are covered by SEA legislation and underlying reasons for the present practice. Based on a critical analysis of mandatory SEA and/or obligation to screen CCPs according to significance criteria, the authors find that 18 out of the 48 CCPs are mandatory to SEA and 9 would require a screening of significance and thereby potentially be followed by a SEA. In practice only one plan was screened and one was environmentally assessed. The legal, democratic and environmental consequences of this SEA practice are critically discussed. Hereunder is the missed opportunity to use the broad environmental scope of SEA to avoid a narrow focus on energy and CO{sub 2} in CCPs, and the question whether this practice in Denmark complies with the EU Directive. -- Highlights: ► It is inevitable that discretionary judgement takes place and will impact on the screening decision. ► The article hereby calls for greater awareness of the discretion and judgement involved in SEA screening. ► Practice seemingly reveals a lack of application of SEA within climate change planning and a lack of explicit screening. ► Absence of SEAs of voluntary plans such as CCPs, have legal consequences, as well as democratic and environmental consequences. ► The vague definition of ‘administrative provision’ seems to impose the lacking SEA.

54 ENVIRONMENTAL SCIENCES↗

An ultrafast symmetry switch in a Weyl semimetal

Topological quantum materials exhibit fascinating properties with important applications for dissipationless electronics and fault-tolerant quantum computers. Manipulating the topological invariants in these materials would allow the development of topological switching applications analogous to switching of transistors. Lattice strain provides the most natural means of tuning these topological invariants because it directly modifies the electron–ion interactions and potentially alters the underlying crystalline symmetry on which the topological properties depend. However, conventional means of applying strain through heteroepitaxial lattice mismatch and dislocations are not extendable to controllable time-varying protocols, which are required in transistors. Integration into a functional device requires the ability to go beyond the robust, topologically protected properties of materials and to manipulate the topology at high speeds. Here in this paper we use crystallographic measurements by relativistic electron diffraction to demonstrate that terahertz light pulses can be used to induce terahertz-frequency interlayer shear strain with large strain amplitude in the Weyl semimetal WTe 2 , leading to a topologically distinct metastable phase. Separate nonlinear optical measurements indicate that this transition is associated with a symmetry change to a centrosymmetric, topologically trivial phase. We further show that such shear strain provides an ultrafast, energy-efficient way of inducing robust, well separated Weyl points or of annihilating all Weyl points of opposite chirality. This work demonstrates possibilities for ultrafast manipulation of the topological properties of solids and for the development of a topological switch operating at terahertz frequencies.

36 MATERIALS SCIENCE↗

Determination of Radiation Energy Response for Thermoluminescent Dosimeter TLD-100: Determination of Organ Dose in Diagnostic Radiology

TLD-100 (thermoluminescent dosimeter) cards (chips) were calibrated using X-rays with energies of 25-250 kV produced by a Cs-137 source. The energy responses of lithium fluoride crystals for different energies of X-rays were studied. QA/QC was then performed in the Albanian Ionizing Radiation Metrology Laboratory. Based on the QA/QC results, the chips were used to study the doses to different organs in diagnostic radiology. Organ dose was evaluated after calculation of e dose in air (Kair), using an ionizing chamber.

61 RADIATION PROTECTION AND DOSIMETRY↗

Refine your search to explore more results.