Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Process noise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Encoding an Oscillator into Many Oscillators

An outstanding challenge for quantum information processing using bosonic systems is Gaussian errors such as excitation loss and added thermal noise errors. Thus, bosonic quantum error correction is essential. Most bosonic quantum error correction schemes encode a finite-dimensional logical qubit or qudit into noisy bosonic oscillator modes. In this case, however, the infinite-dimensional bosonic nature of the physical system is lost at the error-corrected logical level. On the other hand, there are several proposals for encoding an oscillator mode into many noisy oscillator modes. However, these oscillator-into-oscillators encoding schemes are in the class of Gaussian quantum error correction. Therefore, these codes cannot correct practically relevant Gaussian errors due to the established no-go theorems that state that Gaussian errors cannot be corrected by using only Gaussian resources. Here, we circumvent these no-go results and show that it is possible to correct Gaussian errors by using Gottesman-Kitaev-Preskill (GKP) states as non-Gaussian resources. In particular, we propose a non-Gaussian oscillator-into-oscillators code, namely the GKP two-mode squeezing code, and demonstrate that it can quadratically suppress additive Gaussian noise errors in both the position and momentum quadratures except for a small sublogarithmic correction. Furthermore, we demonstrate that our GKP two-mode squeezing code is near optimal in the weak noise limit by proving via quantum information theoretic tools that quadratic noise suppression is optimal when we use two physical oscillator modes. Lastly, in this work we show that our non-Gaussian oscillator encoding scheme can also be used to correct excitation loss and thermal noise errors, which are dominant error sources in many realistic bosonic systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evaluation of the OSC-TV iterative reconstruction algorithm for cone-beam optical CT

Purpose: The present work evaluates an iterative reconstruction approach, namely, the ordered subsets convex (OSC) algorithm with regularization via total variation (TV) minimization in the field of cone-beam optical computed tomography (optical CT). One of the uses of optical CT is gel-based 3D dosimetry for radiation therapy, where it is employed to map dose distributions in radiosensitive gels. Model-based iterative reconstruction may improve optical CT image quality and contribute to a wider use of optical CT in clinical gel dosimetry. Methods: This algorithm was evaluated using experimental data acquired by a cone-beam optical CT system, as well as complementary numerical simulations. A fast GPU implementation of OSC-TV was used to achieve reconstruction times comparable to those of conventional filtered backprojection. Images obtained via OSC-TV were compared with the corresponding filtered backprojections. Spatial resolution and uniformity phantoms were scanned and respective reconstructions were subject to evaluation of the modulation transfer function, image uniformity, and accuracy. The artifacts due to refraction and total signal loss from opaque objects were also studied. Results: The cone-beam optical CT data reconstructions showed that OSC-TV outperforms filtered backprojection in terms of image quality, thanks to a model-based simulation of the photon attenuation process. It was shown to significantly improve the image spatial resolution and reduce image noise. The accuracy of the estimation of linear attenuation coefficients remained similar to that obtained via filtered backprojection. Certain image artifacts due to opaque objects were reduced. Nevertheless, the common artifact due to the gel container walls could not be eliminated. Conclusions: The use of iterative reconstruction improves cone-beam optical CT image quality in many ways. The comparisons between OSC-TV and filtered backprojection presented in this paper demonstrate that OSC-TV can potentially improve the rendering of spatial features and reduce cone-beam optical CT artifacts.

60 APPLIED LIFE SCIENCES↗

SU-F-I-47: Optimizing Protocols for Image Quality and Dose in Abdominal CT of Large Patients

Purpose: Newer CT scanners are able to use scout views to adjust mA throughout the scan in order to achieve a given noise level. However, given constraints of radiologist preferences for kVp and rotation time, it may not be possible to achieve an acceptable noise level for large patients. A study was initiated to determine for which patients kVp and/or rotation time should be changed in order to achieve acceptable image quality. Methods: Patient scans were reviewed on two new Emergency Department scanners (Philips iCT) to identify patients over a large range of sizes. These iCTs were set with a limit of 500 mA to safeguard against a failure that might cause a CT scan to be (incorrectly) obtained at too-high mA. Scout views of these scans were assessed for both AP and LAT patient width and AP and LAT standard deviation in an ROI over the liver. Effective diameter and product of the scout standard deviations over the liver were both studied as possible metrics for identifying patients who would need kVp and/or rotation time changed. The mA used for the liver in the CT was compared to these metrics for those patients whose CT scans showed acceptable image quality. Results: Both effective diameter and product of the scout standard deviations over the liver result in similar predictions for which patients will require the kVp and/or rotation time to be changed to achieve an optimal combination of image quality and dose. Conclusion: Two mechanisms for CT technologists to determine based on scout characteristics what kVp, mA limit, and rotation time to use when DoseRight with our physicians’ preferred kVp and rotation time will not yield adequate image quality are described.

60 APPLIED LIFE SCIENCES↗

Monitoring changes in human activity during the COVID-19 shutdown in Las Vegas using infrasound microbarometers

While studies of urban acoustics are typically restricted to the audio range, anthropogenic activity also generates infrasound (<20 Hz, roughly at the lower end of the range of human hearing). Shutdowns related to the COVID-19 pandemic unintentionally created ideal conditions for the study of urban infrasound and low frequency audio (20–500 Hz), as closures reduced human-generated ambient noise, while natural signals remained relatively unaffected. An array of infrasound sensors deployed in Las Vegas, NV, provides data for a case study in monitoring human activity during the pandemic through urban acoustics. The array records a sharp decline in acoustic power following the temporary shutdown of businesses deemed nonessential by the state of Nevada. This decline varies spatially across the array, with stations close to McCarran International Airport generally recording the greatest declines in acoustic power. Further, declines in acoustic power fluctuate with the time of day. As only signals associated with anthropogenic activity are expected to decline, this gives a rough indication of periodicities in urban acoustics throughout Las Vegas. This study's results reflect the city's response to the pandemic and suggest spatiotemporal trends in acoustics outside of shutdowns.

58 GEOSCIENCES↗

Electric-field sensor based on a double quantum dot in a microcavity

A scheme for an optical quantum external-electric-field sensor based on a double quantum dot placed in a high-Q semiconductor microcavity is proposed. A model of the dynamic processes occurring in this system is developed, its spectral characteristics are investigated, and the noise stability of the sensor is examined. It is demonstrated that, owing to design features, the device has a number of advantages, including high sensitivity, the presence of different excitation and measurement channels, and the possibility of accurate determination of the spatial field distribution.

36 MATERIALS SCIENCE↗

Two massive white dwarfs from NGC 2323 and the initial–final mass relation for progenitors of 4–6.5 M{sub ⊙}

We observed a sample of 10 white dwarf candidates in the rich open cluster NGC 2323 (M50) with the Keck Low-Resolution Imaging Spectrometer. The spectroscopy shows eight to be DA white dwarfs, with six of these having high signal-to-noise ratio appropriate for our analysis. Two of these white dwarfs are consistent with singly evolved cluster membership, and both are high mass ∼1.07 M{sub ⊙}, and give equivalent progenitor masses of 4.69 M{sub ⊙}. To supplement these new high-mass white dwarfs and analyze the initial–final mass relation (IFMR), we also looked at 30 white dwarfs from publicly available data that are mostly all high-mass (≳0.9 M{sub ⊙}). These original published data exhibited significant scatter, and to test if this scatter is true or simply the result of systematics, we have uniformly analyzed the white dwarf spectra and have adopted thorough photometric techniques to derive uniform cluster parameters for their parent clusters. The resulting IFMR scatter is significantly reduced, arguing that mass-loss rates are not stochastic in nature and that within the ranges of metallicity and mass analyzed in this work mass loss is not highly sensitive to variations in metallicity. Lastly, when adopting cluster ages based on Y{sup 2} isochrones, the slope of the high-mass IFMR remains steep and consistent with that found from intermediate-mass white dwarfs, giving a linear IFMR from progenitor masses between 3 and 6.5 M{sub ⊙}. In contrast, when adopting the slightly younger cluster ages based on PARSEC isochrones, the high-mass IFMR has a moderate turnover near an initial mass of 4 M{sub ⊙}.

79 ASTRONOMY AND ASTROPHYSICS↗

Data processing method for a weak, moving telemetry signal

Method of processing data from a spacecraft, where the carrier has a low signal-to-noise ratio and wide unpredictable frequency shifts, consists of analogue recording of the noisy signal along with a high-frequency tone that is used as a clock to trigger a digitizer.

Kendall, W. B.↗

Technique minimizes the effects of dropouts on telemetry records

Recorder deficiencies are minimized by using two-channel system to prepare two tapes, each having noise, wow and flutter, and dropout characteristics of channel on which it was made. Processing tapes by computer and combining signals from two channels produce single tape free of dropouts caused by recording process.

Anderson, T. O.↗

NASA gear research and its probable effect on rotorcraft transmission design

The results of the NASA gear research is reviewed as well as those programs which are presently being undertaken. Research programs studying pitting fatigue, gear steels and processing, life prediction methods, gear design and dynamics, elastohydrodynamic lubrication, lubrication methods and gear noise are presented. The impact of advanced gear research technology on rotorcraft transmission design is discussed.

Zaretsky, E. V.↗

NASA gear research and its probable effect on rotorcraft transmission design

The NASA Lewis Research Center devised a comprehensive gear technology research program beginning in 1969, the results of which are being integrated into the NASA civilian Helicopter Transmission System Technology Program. Attention is given to the results of this gear research and those programs which are presently being undertaken. In addition, research programs studying pitting fatigue, gear steels and processing, life prediction methods, gear design and dynamics, elastohydrodynamic lubrication, lubrication methods and gear noise are presented. Finally, the impact of advanced gear research technology on rotorcraft transmission design is discussed.

Zaretsky, E. V.↗

Fast frequency acquisition via adaptive least squares algorithm

A new least squares algorithm is proposed and investigated for fast frequency and phase acquisition of sinusoids in the presence of noise. This algorithm is a special case of more general, adaptive parameter-estimation techniques. The advantages of the algorithms are their conceptual simplicity, flexibility and applicability to general situations. For example, the frequency to be acquired can be time varying, and the noise can be nonGaussian, nonstationary and colored. As the proposed algorithm can be made recursive in the number of observations, it is not necessary to have a priori knowledge of the received signal-to-noise ratio or to specify the measurement time. This would be required for batch processing techniques, such as the fast Fourier transform (FFT). The proposed algorithm improves the frequency estimate on a recursive basis as more and more observations are obtained. When the algorithm is applied in real time, it has the extra advantage that the observations need not be stored. The algorithm also yields a real time confidence measure as to the accuracy of the estimator.

Kumar, R.↗

Fast frequency acquisition via adaptive least squares algorithm

A new least squares algorithm is proposed and investigated for fast frequency and phase acquisition of sinusoids in the presence of noise. This algorithm is a special case of more general, adaptive parameter-estimation techniques. The advantages of the algorithms are their conceptual simplicity, flexibility and applicability to general situations. For example, the frequency to be acquired can be time varying, and the noise can be non-Gaussian, nonstationary and colored. As the proposed algorithm can be made recursive in the number of observations, it is not necessary to have a priori knowledge of the received signal-to-noise ratio or to specify the measurement time. This would be required for batch processing techniques, such as the fast Fourier transform (FFT). The proposed algorithm improves the frequency estimate on a recursive basis as more and more observations are obtained. When the algorithm is applied in real time, it has the extra advantage that the observations need not be stored. The algorithm also yields a real time confidence measure as to the accuracy of the estimator.

Kumar, Rajendra↗

Compensator design for stability enhancement with collocated controllers

A continuum model rather than a finite element model is used. The optimal compensator design is formulated as a stochastic regulator problem and is shown to be solvable by the general infinite-dimensional theory developed by the author despite the lack of exponential stabilizability. Infinite-dimensional steady-state Riccati equations characterizing the feedback control gain and the Kalman filter gain operators can be solved explicitly. The associated performance indexes including the mean-square control-effort are calculated in closed form. As a first approximation, the compensator transfer function can be realized as a bank of bandpass filters in parallel centered at the undamped mode frequencies. Numerical calculations for the gain and bandwidths for a typical configuration are presented. The performance of the compensator is evaluated when in fact in the true model there is no actuator noise. The theoretical problem involved is to show that the infinite-dimensional stochastic process is asymptotically stationary. It is possible to calculate the steady-state covariance in closed form and thereby calculate performance indexes of interest explicitly, facilitating the choice of optimal design parameters.

Balakrishnan, A. V.↗

Comparison of different fractal dimension measuring algorithms for RE-TM M-O films

Noise in magneto-optical recording devices is discussed. In general, it appears that either the divider technique or amplitude spectrum technique may be used interchangeably to measure the fractal dimension (D) in the domain wall structure of ideal images. However, some caveats must be observed for best results. The divider technique is attractive for its simplicity and relatively modest computation requirements. However, it is sensitive to noise, in that noise pixels that touch the domain boundary are interpreted as being part of the boundary, skewing the measurement. Also, it is not useful in measuring nucleation-dominated films or domains that have significant amounts of structure within the interior of the domain wall. The amplitude spectrum method is more complex, and less intuitive than the divider method, and somewhat more expensive to implement computationally. However, since the camera noise tends to be white, the noise can be avoided in the measurement of D by avoiding that portion of the curve that is flat (due to the white noise) when the least squares line is fit to the plot. Also, many image processing software packages include a Fast Fourier Transformation (FFT) facility, while the user will most likely have to write his own edge extraction routine for the divider method. The amplitude spectrum method is a true two dimensional technique that probes the interior of the domain wall, and in fact, can measure arbitrary clusters of domains. It can also be used to measure grey-level images, further reducing processing steps needed to threshold the image.

Bernacki, Bruce E.↗

Convergence characteristics of the multiple input, multiple output LMS algorithm

The convergence characteristics of the multiple input, multiple output LMS algorithm, as applied to active noise and vibration control systems, are examined. The mean square error during the convergence process, as well as the final converged value, are examined analytically and in computer simulation. It is shown that the ratio of number of error sensors to number of control sources has a significant influence upon both the converging and converged value of the mean square error. Other active control system variables, such as the inherent time delays and structural/acoustic transfer functions, are also shown to have a significant influence upon the convergence process.

Snyder, Scott D.↗

The quasi-periodic oscillations and very low frequency noise of Scorpius X-1 as transient chaos - A dripping handrail?

We present evidence that the quasi-periodic oscillations (QPO) and very low frequency noise (VLFN) characteristic of many accretion sources are different aspects of the same physical process. We analyzed a long, high time resolution EXOSAT observation of the low-mass X-ray binary (LMXB) Sco X-1. The X-ray luminosity varies stochastically on time scales from milliseconds to hours. The nature of this variability - as quantified with both power spectrum analysis and a new wavelet technique, the scalegram - agrees well with the dripping handrail accretion model, a simple dynamical system which exhibits transient chaos. In this model both the QPO and VLFN are produced by radiation from blobs with a wide size distribution, resulting from accretion and subsequent diffusion of hot gas, the density of which is limited by an unspecified instability to lie below a threshold.

Scargle, Jeffrey D.↗

Development of nonintrusive, scatter-independent techniques for measurement of liquid density inside dense sprays

A nonintrusive optical technique for measuring the liquid density in sprays used to simulate LOX injector flows is under development. This manuscript is a report on work toward that development which is currently in progress. The technique is a scatter-independent, absorption-based approach which depends on the numerical inversion of a collection of absorption profiles. For the case in which visible radiation passes through liquid-gas interfaces so numerous in sprays, substantial reductions and alterations in the signal result from scattering even in the absence of absorption. To avoid these problems, X-Rays will be used as the absorbed radiation. The experimental process is simulated by integrating the absorption spectrum for a known distribution, adding instrument noise to this 'measurement', creating a projection from the 'measurement', filtering the projection, inverting the projection, and comparing the results with the original prescribed distribution.

Hartfield, Roy↗

Refine your search to explore more results.