Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Precision”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Precision Measurements of Lifetime and $\bf CP$ Violation Phase in the $\bf B^{0}_{s}$ Meson with the DØ Detector

The Standard Model of Partice Physics (SM) is probably the most successful theory, regarding to his predictions. The SM prediction for $CP$ violation is not enough to explain the overwhelming asymmetry among the matter and anti-matter abundance. Measuring some process where $CP$ violation is different to the one predicted by the SM would be a clear signal for Physics Beyond the Standard Model. The SM prediction for the $CP$ violation phase, $\phi_{s}$, in the $B^{0}_{s}$ meson is practically equal to zero for the current experiments. This means that measuring a deviation from zero in $\phi_{s}$ could be an indication for Physics Beyond the SM. On the other hand, the approximation based on the ``heavy quark symmetry'' let approximated calculations of the fundamental quantities of those hadrons containing a heavy quark, $c,b,t$. These calculations are expressed as expansions on inverse powers of the heavy quark mass in such hadron. This formalism is called `` Heavy Quark Effective Theory'' (HQET), and has been successful predicting some properties of the heavy hadrons. The HQET prediction for the lifetime ratio the $B^{0}_{d}$ and $B^{0}_{s}$ is practically equal to one. So, measuring with good precision the $B^{0}_{s}$ lifetime is also a way to test an approximation based on the SM. In this thesis it is detailed presented the method to measure the $\phi_{s}$ and the lifetime ratio of the $B^{0}_{d}$ and $B^{0}_{s}$, among other quantities, with the DØ located in the Fermi National Accelerator Laboratory, in the United States.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Precision Neutrino Oscillation Measurements using Simultaneous High-Power, Low-Energy Project-X Beams

The first phase of the long-baseline neutrino experiment, LBNE10, will use a broadband, high-energy neutrino beam with a 10-kt liquid argon TPC at 1300 km to study neutrino oscillation. In this paper, we describe potential upgrades to LBNE10 that use Project X to produce high-intensity, low-energy neutrino beams. Simultaneous, high-power operation of 8- and 60-GeV beams with a 200-kt water Cerenkov detector would provide sensitivity to nu_mu to nu_e oscillations at the second oscillation maximum. We find that with ten years of data, it would be possible to measure sin2(2theta_13) with precision comparable to that expected from reactor antineutrino disappearance and to measure the value of the CP phase, delta_CP, with an uncertainty of (5-10) degrees. This document is submitted for inclusion in Snowmass 2013.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High Throughput, High Precision Hot Testing Tool for HBLED Wafer Level Testing

The Socrates research effort developed an in depth understanding and demonstrated in a prototype tool new precise methods for teh characterization of color characteristics and flux from individual LEDs for the production of uniform quality lighting. This effort was focused on improving the color quality and consistency of solid state lighting and potentially reducing characterization costs for all LED product types. The patented laser hot testing method was demonstrated to be far more accurate than all current state of the art color and flux characterization methods in use by the solid state lighting industry today. A seperately patented LED grouping method (statistical binning) was demonstrated to be a useful approach to improving utilization of entire lots of large color and flux distributions of manufactured LEDs for high quality color solid-state lighting. At the conclusion of the research in late 2015 the solid-state lighting industry was however generally satisfied with its existing production methods for high quality color products for the small segment of customers that demand it, albeit with added costs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Evaluation of the Single-precision Floatingpoint Vector Add Kernel Using the Intel FPGA SDK for OpenCL

Open Computing Language (OpenCL) is a high-level language that enables software programmers to explore Field Programmable Gate Arrays (FPGAs) for application acceleration. The Intel FPGA software development kit (SDK) for OpenCL allows a user to specify applications at a high level and explore the performance of low-level hardware acceleration. In this report, we present the FPGA performance and power consumption results of the single-precision floating-point vector add OpenCL kernel using the Intel FPGA SDK for OpenCL on the Nallatech 385A FPGA board. The board features an Arria 10 FPGA. We evaluate the FPGA implementations using the compute unit duplication and kernel vectorization optimization techniques. On the Nallatech 385A FPGA board, the maximum compute kernel bandwidth we achieve is 25.8 GB/s, approximately 76% of the peak memory bandwidth. The power consumption of the FPGA device when running the kernels ranges from 29W to 42W.

97 MATHEMATICS AND COMPUTING↗

Precision measurement of quasi-elastic transverse and longitudinal response functions in the range 0.55 GeV/c lte |q-right arrow| lte 1.0 GeV/c

The Coulomb Sum is defined by the quasi-elastic nucleon knock-out process and it is the integration of the longitudinal response function over the energy loss of the incident electron. The Coulomb sum goes to the total charge at large q. The existing measurements of the Coulomb Sum Rule show disagreement with the theoretical calculations for the medium and heavy nuclei. To find the reason behind the disagreement might answer the question of whether the properties of the nucleons are affected by the nuclear medium or not. In order to determine the Coulomb Sum in nuclei, a precision measurement of inclusive electron scattering in the quasi-elastic region was performed at the Thomas Jefferson National Accelerator Facility. Incident electrons with energies ranging from 0.4 GeV to 4 GeV scattered off 4He,12C,56Fe and 208Pb nuclei at four scattering angles (15 deg.; 60 deg.; 90 deg.; 120 deg.) and scattered energies ranging from 0.1 GeV to 4 GeV. The Born cross sections were extracted for the Left High Resolution Spectrometer (LHRS) and the Right High Resolution Spectrometer 56Fe data. The Rosenbluth separation was performed to extract the transverse and longitudinal response functions at 650 MeV three-momentum transfer. The preliminary results of the longitudinal and transverse functions were extracted for 56Fe target at 650 MeV three-momentum transfer.

Atac, Hamza↗

Final Report: Advanced Detector Technologies for Precision Measurement of Inflation, Dark Energy, and Neutrino Masses with the Cosmic Microwave Background

Precision measurements of the Cosmic Microwave Background (CMB) provide unparalleled op- portunities to probe the conditions in the early universe and thereby explore particle physics and gravity at the highest energies yet; measure the number of neutrino species and the sum of the neutrino masses with sensitivity beyond what is achievable with planned terrestrial experiments; improve our knowledge of dark energy; and search for other forms of new physics. The P-5 panel recognized the importance and potential of future CMB observations and recommended the DOE fund a stage four CMB experiment (CMB-S4) under all budget scenarios with construction commencing near the end of this decade. The objective of this proposal is to develop and demonstrate new technologies in time to maximize the science return of CMB-S4. The proposed technologies include: (i) broad band metamaterial antireflection coatings on relevant lenses with negligible absorptive and reflective losses; (ii) filters that reduce out of band optical loading with near perfect in band transmission; (iii) broad-band continuously spinning metamaterial half wave plates that boost the sensitivity to inflationary gravitational waves on large angular scales and mitigate systematics with minimal penalty to the instantaneous sensitivity; and (iv) broad band detectors that will enable excellent foreground discrimination while simultaneously maximizing the sensitivity to the signals from inflation and neutrinos. Together these technologies can realize significant improvements in instrumental sensitivity and control of systematic effects. This improvement in raw sensitivity could be used to reduce costs without sacrificing science by deploying a smaller number of more sensitive detectors, or to improve the sensitivity of CMB-S4 to physics parameters including reducing the error bar on r by the inverse of the mapping speed improvement. Beyond raw sensitivity these technologies address key systematics including polarization mixing and galactic foregrounds and enable CMB-S4 to test the shape of the polarization power spectrum out to larger angular scales further boosting measurements of inflation. In this report we detail the progress that has been made in these technical areas. This includes: (i) a demonstration of 4:1 bandwidth AR coating technology and a detailed understanding of the production challenges, (ii) prototype filters that incorporate absorptive and reflective components into silicon, (iii) a prototype broad band HWP fabricated from metamaterial silicon, and (iv) detector designs spanning 20-350 GHz with an understanding of the difficulties associated with bandwidths greater than one octave.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Photometric and Astrometric Properties of DECam as Enablers of Precision Science [Slide]

Precise and accurate calibration of a wide-field imager with the areal coverage of DECam is not a trivial task. In this talk, I will discuss the astrometric and photometric calibration of individual DECam images, as well as that of DECam surveys, with particular reference to the Dark Energy Survey (DES) and the Blanco Imaging of the Southern Sky (BLISS) survey.

79 ASTRONOMY AND ASTROPHYSICS↗

Precision Timing with Silicon Photomultipliers

• CMS MTD is important for an expanded physics reach : we expect 20- 25% effective luminosity increase in crucial precision Higgs measurements. • Our project is significantly advanced – the sensor performance is close to specification. • We are heavily involved in efforts to ensure 30 ps time resolution for sensors throughout the HL-LHC run.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Precision Measurement of Electron Antineutrino Disappearance in the Daya Bay Experiment

The Daya Bay reactor neutrino experiment studies the disappearance of electron antineutrinos from reactor cores at the Daya Bay Power Plant located in China. Daya Bay has made a precision measurement of one of the parameters describing the quantum mechanical mixing between neutrino flavor states and mass states, the mixing angle $\theta_{13}$. One source of systematic uncertainty in the measurement is due to background induced by cosmic ray muons. The detectors are located underground to minimize the cosmic flux, but the residual backgrounds must be measured. This program will focus on the study and measurement of the cosmic muon-induced backgrounds at Daya Bay with a goal of achieving the lowest possible level of background-related systematics on the disappearance measurement. In addition to providing crucial input to the Daya Bay disappearance analysis, measurements of the muon flux and the production of neutrons and radioactive nuclei by cosmic muons will be of general interest to other underground experiments such as double beta decay and dark matter searches.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Towards New Physics Through Precision Measurements in B$^0_S$ and $\tau$ Decays

Despite the correct and consistent description of the elementary particle interactions, there is evidence that the Standard Model (SM) is an incomplete theory. Solving the issues faced by the SM requires the introduction of new interactions and, if such interactions exist, they can be observed as deviations in the SM predictions or forbidden processes. Particularly of interest for this work are the B$^0_s$ mesons and $\tau$ leptons produced in the DØ and Belle II experiments, respectively, where the luminosity provides the statistics for high precision SM measurements and searches for new physics. In this work, the lifetime measurement of the B$^0_s$ meson in the decay channel $B^0_s \to J/\Psi f_0(980)$ is reported, which is a CP-odd final state. Using 10.4 fb$^{-1}$ of data collected with the DØ detector in Run II of the Tevatron, the lifetime of the CP-odd component of the B$^0_s$ meson is measured to be $\tau(B^0_s)$ = 1.70$\pm$0.14 (stat)$\pm$0.05 (syst) ps. This measurement is closely related to the $B^0_s - \bar{B^0_s}$ mixing and searches for new CP violation mechanisms. Additionally, the $\tau$ lepton physics program of Belle II is reviewed and two sensitivity studies are shown: (i) $\tau^- \to \eta \pi^-\pi^0 \nu_{\tau}$, which in the isospin symmetry limit SU(2) is a cross-check of consistency with the cross section $\sigma(e^+e^- \to \eta \pi^+ \pi^-$) at low energies; (ii) $\tau^- \to \eta \pi^- \nu_{\tau}$, which has never been observed and, given the suppression by G-parity, it allows the searches of scalar and tensor interactions. Estimations from 1 to 20 ab$^{-1}$ are shown, corresponding to the integrated luminosity expected during the first years of operation of Belle II.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Engineering Precisely Controlled Negative and Zero Thermal Expansion Behaviors in Metal-Organic Frameworks

Positive thermal expansion can cause significant stress or even catastrophic device failure in applications where materials are placed in confined environments. At material interfaces such as coatings, thermal expansion effects can also lead to cracking and peeling behavior. The ability to impart controlled thermal expansion properties in an array of designs via additive manufacturing technologies would mitigate such problems and bring significant value to various materials science and engineering challenges. Negative thermal expansion materials are of interest for composite material applications whereby they can compensate for the behavior of a positive thermal expansion matrix. This Truman Fellowship LDRD research project presents complimentary experimental and molecular modeling results towards the fundamental understanding and development of metal-organic framework (MOF) materials with controlled thermal expansion properties. Design strategies for imparting precisely tailored negative, zero, and positive thermal expansion regimes in MOFs are studied and the implications of these design strategies for the use of MOFs as an emergent negative thermal expansion material class are examined. Challenges towards exploiting this nanoscale behavior at length scales relevant to composite material systems are introduced. ACKNOWLEDGEMENTS I will be forever grateful to the Truman Fellowship Selection Committee for providing me with the opportunity to pursue this research project. The unique opportunity to carry out this exciting scientific research with all of the resources and support that Sandia has to offer has been a truly rewarding experience. I would like to especially thank Yolanda Moreno for her endless assistance throughout my time as a Truman Fellow. It is hard to imagine a more supportive and stimulating scientific environment to carry out this research. I would also like to thank all of my colleagues and the individuals that have collaborated with me throughout this Fellowship, both internal and external to Sandia. Many of you appear as co-authors on the publications resulting from this LDRD, including especially fruitful collaborations with researchers at the Georgia Institute of Technology and the University of Amsterdam. I cannot express enough my gratitude for the significant role that you all played in shaping my educational experience and the success during my time at Sandia as a Truman Fellow.

36 MATERIALS SCIENCE↗

Development of Tunable, Precision Permanent Magnet Phase Shifter for X-Ray FEL

In an X-ray free-electron laser (XFEL), a high quality relativistic electron beam from a linear accelerator traverses an array of undulator magnets to generate a high power X-ray beam by allowing the FEL to reach saturation. In many XFELs, phase shifters haven’t been commonly used or included in their designs. The importance of the phase shifter was recognized only recently. A phase shifter can be constructed using either an electromagnet (EM) or a permanent magnet (PM). EM phase shifters are heavy, complex to operate, and take more valuable longitudinal space between the undulators. Compared to EMs, the PMs have several outstanding advantages, including compactness, lighter weights, simple operation, and low maintenance. This project has developed an innovative design of fixed-gap, tunable PM-based compact phase shifter for the XFEL. While keeping the poles and gap fixed, the new design incorporates proven features from the prior work, along with novel field tuning methods, which allow the field strength to be adjusted within a reasonably large range to achieve the desired range of the phase delay control. The PM design without electric currents and power electronics associated with EMs improves reliability by reducing the number of possible points of failure and lowers the operation cost. The compactness makes it possible to use PM phase shifters in the existing XFELs with small gaps between adjacent undulators, as well as in the new XFELs without significantly increasing the FEL length. In Phase I we have accomplished the followings; 1) determined the optimum physics parameters for both weak and strong phase shifters; 2) conducted magnetic design with concrete magnetic and geometrical parameters of actual produced PM materials; 3) provided solutions to achieve precision fine tuning of the magnetic fields with unique methods; 4) elaborated a design based upon ease of manufacturing and cost analysis; and 5) produced rare-earth PM materials, which will be used for prototyping in Phase II. The phase I results provide a foundation for the research and development in the Phase II project, which will aim at building two full-size PM phase shifters and testing at SLAC National Accelerator Laboratory. This project will significantly provide the potential to bring a paradigm change in accelerator technology, replacing conventional electromagnets for many existing accelerator applications and allowing the development of new applications in completely new areas. For example, the PM FEL phase shifters can help significantly improve coherence and power of an XFEL. The proposed use of PM phase shifters will also bring significant cost savings to the construction, operation and maintenance of FEL facilities.

43 PARTICLE ACCELERATORS↗

Precision Measurements of Electron-Proton Elastic Scattering Cross Sections at Large Q2

The electromagnetic form factors are fundamental quantities characterizing the internal structure of the nucleon. Their measurements have provided significant insight into the spatial distribution and interaction of quarks inside the proton. The knowledge of high Q2 form factors proves essential in understanding the properties of quantum chromodynamics in the transition region from non-perturbative to perturbative behavior. It also provides important links to generalized parton distributions, which describe the three-dimensional structure of hadrons at the parton level. In view of the significant theoretical research activities in this field, high quality experimental data are crucial for providing stringent tests and benchmarks to guide and test different models. The form factors can be accessed in experiments by measuring elastic scattering of electrons off a hydrogen target. Experiment E12-07-108, which took place at the Thomas Jefferson National Accelerator Facility, conducted precise measurements of the unpolarized e-p elastic scattering cross section over a Q2 range of 0.6-16.5 GeV2 . This thesis presents the results for 7 kinematic settings with total uncertainties that are 1.5 times smaller than those of the existing data at large Q2 . The proton magnetic form factors were extracted using a parameterization of the form factor ratio obtained from recent polarized e-p scattering experiments. Comparisons to existing global and phenomenological fits are presented.

Ou, Longwu↗

The ETROC Project: Precision Timing ASIC Development for LGAD-based CMS Endcap Timing Layer (ETL) Upgrade

The ETROC (Endcap Timing Readout Chip) is being developed for the LGAD-based CMS Endcap Timing Layer (ETL) at HL-LHC. The ETL on each side of the interaction region will be instrumented with a two-disk system of MIP-sensitive LGAD silicon devices to be read out by ETROCs for precision timing measurement with down to 30 ps timing resolution. The ETROC is designed to handle a 16 x 16 pixel cell matrix, with each pixel cell being 1.3 mm x 1.3 mm to match the LGAD sensor pixel size. Approximately 15% of the sensors near the highest eta region will experience hadron fluence above 1e15 neq/cm² towards end of operation of HL-LHC, resulting in small signal amplitude with LGAD gain reduced to around 10. For this reason, the front-end design for preamplifier and discriminator has been specifically optimized for the reduced LGAD signals, with enough flexibilities to meet the ETL specific needs for time resolution, power budget and radiation profile.

97 MATHEMATICS AND COMPUTING↗

Precision Measurement of the Proton Magnetic Form Factor at High Q2

Elastic electromagnetic form factors characterize the distribution of electric charge and magnetization current inside the nucleon and reflect the internal structure determined by Quantum Chromodynamics. Existing data on the proton magnetic form factor at high Q2 (the 4-momentum transfer squared) have large statistical and systematic uncertainties. The GMp experiment E12-07-108 was one of the first set of experiments to run in Hall A at Jefferson Lab after the 12 GeV upgrade with the goal of this experiment to precisely measure the electron-proton elastic cross section for Q2 up to 17 GeV2 with an accuracy of better than 2% - several times better than existing data in this Q2 range. This will allow further tests of form factor scaling predicted by pQCD and, additionally, will be an important benchmark for many other experiments where elastic electron-proton scattering is used for normalization. Since, GMp data were taken at lower ?(virtual photon polarization) than SLAC data, the measured cross sections recieve a smaller contribution from the electric form factor. This dissertation analyzed the GMp experiment data for five different kinematic settings determining the form factor with total uncertainties nearly two times smaller than the existing data at these Q2. This dissertation also presents the results of all Fall 2016 and Spring 2016 GMp experiment data. The proton magnetic form factors were extracted using both the Rosenbluth separation method and a parameterization of the form factor ratio (?pGpE=GpM) obtained from a fit to the existing cross section data. At the end of this thesis, the extracted GMp form factor data is compared to the existing data. The results for ?pGpE=GpM from Rosenbluth separations are found to be consistent with previous extractions, but with significantly reduced uncertainties, further highlighting the discrepancy with the polarization transfer technique. This data set can provide significant additional constraints on contributions from two-photon exchange.

Narayan Gautam, Thir↗

Precision γ-ray branching ratio measurements for long-lived fission products of importance to nuclear-security applications (TAMU Annual Report 2020)

Continuing with our effort of precisely measuring the branching ratios for long-lived fission products we have collected and measured two radiopure ¹⁵⁶Eu samples. The samples were collected on thin (40 μg/cm²) carbon-foil backings using a low-energy mass-separated beam of A = 156 fission products from CARIBU at Argonne National Laboratory. During collection, a HPGe detector was used to continuously monitor the implantation rate by detecting the characteristic γ rays emitted following the β decay of the shorter-lived fission products. The first sample had measured activity of 375 Bq while the second one had an activity of 700 Bq. The implanted samples were then shipped to Texas A&M University for measurement of the subsequent decay.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Refine your search to explore more results.