Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PV system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Frequency Stability Enhancement in a Fully Solar Power Grid: A Case Study on the Saudi Model

Recently, renewable energy sources (RES) such as solar photovoltaic (PV) have been recognized for their significant potential. Several studies have explored the issue of frequency stability with high RES penetration. A significant observation related to this issue is the decline in the weighted short circuit ratio (WSCR), which has the potential to adversely affect system stability. This research uniquely focuses on the gradual transition of the Saudi Electricity Company (SEC) system to a fully integrated solar PV grid, offering insight and methodology that can be adapted for other power systems. While a variety of mitigation methods are available, synchronous condensers (SC) were used in this study to stabilize grid frequency, and their implementation has been shown to improve the overall performance of the system. In response to the observed decline in WSCR, a comprehensive short circuit analysis was applied across all regions in the Saudi power grid model to evaluate the reduction in short circuit power and highlight areas requiring enhancement. Finally, scenarios illustrating frequency response with a gradual increase in SCR were analyzed, with the objective of establishing a stable, fully solar PV power system that is resilient to sudden power grid disturbances.

14 SOLAR ENERGY↗

Building Scale vs. Community Scale Net-Zero Energy Performance

Many government and industry organizations are focusing building energy-efficiency goals around producing individual net-zero buildings (nZEBs), using photovoltaic (PV) technology to provide on-site renewable energy after substantially improving the energy efficiency of the buildings themselves. Seeking net-zero energy (NZE) at the community scale instead introduces the possibility of using a wider range of renewable energy technologies, such as solar-thermal electricity generation, solar-assisted heating/cooling systems, and wind energy, economically. This paper reports results of a study comparing NZE communities to communities consisting of individual nZEBs. Five scenarios are examined: 1) base case – a community of nZEBs with roof mounted PV systems; 2) NZE communities served by wind turbines on leased land; 3) NZE communities served by wind turbines on owned land; 4) communities served by solar-thermal electric generation; and 5) communities served by photovoltaic farms. All buildings are assumed to be highly efficient, e.g., 70% more efficient than current practice. The scenarios are analyzed for two climate locations (Chicago and Phoenix), and the levelized costs of electricity for the scenarios are compared. The results show that even for the climate in the U.S. most favorable to PV (Phoenix), more cost-effective approaches are available to achieving NZE than the conventional building-level approach (rooftop PV with aggressive building efficiency improvements). The paper shows that by expanding the measurement boundary for NZE, a community can take advantage of economies of scale, achieving improved economics while reaching the same overall energy-performance objective.

17 WIND ENERGY↗

AI & Physics-Based Bad Command/Data Detection in Large Power Electronics Systems: Multi-Port Autonomous Reconfigurable Solar Power Plant (MARS)

Detection of bad data from measurement sensors and bad commands from control centers need to be carried out to avoid instabilities within large power electronics systems. Towards the same, in this paper, model and data driven methods are proposed to identify anomalies in measured data and commands received by large power electronics systems. The large power electronics system considered in this paper is a multi-port autonomous reconfigurable solar power plant (MARS), which consists of photovoltaic (PV) and energy storage systems (ESSs) that connect to high-voltage direct current (HVdc) system and transmission ac power grid. The proposed algorithms in the MARS power plant to detect bad data from measurements and bad commands from control centers are evaluated in simulations and hardware-in-the-loop (HIL) tests. Furthermore, it has been observed that the proposed algorithms are able to detect bad measurements and commands in all the use cases evaluated.

14 SOLAR ENERGY↗

Design and Performance of Solar Decathlon 2011 High-Penetration Microgrid: Preprint

The U.S. Department of Energy Solar Decathlon challenges collegiate teams to design, build, and operate solar-powered houses that are cost-effective, energy-efficient, and attractive. The Solar Decathlon 2011 was held in Washington, D.C., from September 23 to October 2, 2011 . A high-penetration microgrid was designed, installed, and operated for the Solar Decathlon 2011 to grid-connect 19 highlyenergy-efficient, solar-powered competition houses to a single utility connection point. The capacity penetration of this microgrid (defined as maximum PV generation divided by maximum system load over a two-week period) was 74% based on 1-minute averaged data. Temporary, ground-laid conductors and electrical distribution equipment were installed to grid-connect the Solar Decathlon village,which included the houses as well as other electrical loads used by the event organizers. While 16 of the houses were connected to the 60 Hz microgrid, three houses from Belgium, China, and New Zealand were supplied with 50 Hz power. The design of the microgrid, including the connection of the houses powered by 50 Hz and a standby diesel generator, is discussed in this paper. In addition to theutility-supplied net energy meters at each house, a microgrid monitoring system was installed to measure and record energy consumption and PV energy production at 1-second intervals at each house. Bidirectional electronic voltage regulators were installed for groups of competition houses, which held the service voltage at each house to acceptable levels. The design and successful performance ofthis high-penetration microgrid is presented from the house, microgrid operator, and utility perspectives.

14 SOLAR ENERGY↗

Enhanced convection for higher module and system efficiency (Final Technical Report)

The goal of this work is to develop new solar photovoltaic (PV) modules and solar system-scale designs that promote an increase of the convective heat transfer coefficient of at least 40%, reducing the operating temperature of the solar PV panels, and leading to a boost on the annual energy yield by at least 5%. By achieving this goal, we further foresee decreasing solar panel degradation by +0.3%/year, reducing the LCOE by 2.9-4.5¢/kWh. Currently, this question and/or approach is not considered though it is a relevant factor in performance/efficiency. The technology proposed will be at a mature stage by the end of the project and could be aligned to be proven on a full-field test. PV users, installers and manufacturers will be interested in the technology due to the aforementioned benefits. The work was conducted through a suite of wind tunnel experiments, numerical simulations and field experiments. These were then evaluated through a correlation encompassing the entire data set and implementing findings into NREL SAM. The work resulted in eight peer reviewed publications with three others in preparation. The key results of the project are 1.) Showing the capability of increasing the solar farm power production by increasing the heat transfer coefficient; 2.) Providing strategies for achieving this through large scale arrangement manipulation (heights, spacings, angles), flow deflectors and vortex generators; 3.) Demonstrating scalability of results by comparing numerical simulations, wind tunnel experiments and field experiments; 4.) Providing a correlation to be able to capture the various arrangements while exploiting the heat transfer coefficient; and 5.) Proving the feasibility of such strategies and their capacity through a comprehensive techno-economic analysis. For the heat transfer coefficients, gains of 40% were attained and increases in power in the excess of 5% were observed. For heat mitigation strategies, consideration at the PV array scale were inter-panel spacing, panel height and panel angles while at the module level, wind breaks such as solid walls and selected gaps were evaluated as well as vortex generators on the panel. All proposed strategies saw an increase in heat transfer coefficient. For scalability, results were compared against field experiments and a correlation for the heat transfer quantity was attained leading to a parametric understanding of the variations and impact in the heat transfer coefficient independent of tools implemented (wind tunnel/numerical simulations). The strategies were also further assessed by a technoeconomic analysis finding improvements based on LCOE with respect to location (several states with varies atmospheric conditions/geographic locations) yielded different results. Improvements on this end were also observed especially towards the colder climates and when considering bi-facial modules. The quantitative demonstrations of such conclusions are provided in the main portion of this document with complementary results and their narration. Milestones and go/no-go points were successfully met in the project.

14 SOLAR ENERGY↗

Power Hardware-in-the-Loop Testing of a Smart Distribution System

This paper presents the results of the third and final phase of the National Renewable Energy Lab (NREL) INTEGRATE demonstration: Smart Distribution. For this demonstration, high penetrations of solar PV and wind energy systems were simulated in a power hardware-in-the-loop set-up using a smart distribution test feeder. Simulated and real DERs were controlled by a real-time control platform, which manages grid constraints under high clean energy deployment levels. The power HIL testing, conducted at NREL's ESIF smart power lab, demonstrated how dynamically managing DER increases the grid's hosting capacity by leveraging active network management's (ANM) safe and reliable control framework. Results are presented for how ANM's real-time monitoring, automation, and control can be used to manage multiple DERs and multiple constraints associated with high penetrations of DER on a distribution grid. The project also successfully demonstrated the importance of escalating control actions given how ANM enables operation of grid equipment closer to their actual physical limit in the presence of very high levels of intermittent DER.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Floating Photovoltaic System Cost Benchmark: Q1 2021 Installations on Artificial Water Bodies

In this report, we conduct a bottom-up analysis of the installed costs for FPV systems deployed on artificial water bodies under average site conditions (wind load of about 40 m/s, snow load of 20 psf, water depth of 50 m, water level variation of 10 m, and swell height of 1 m). We estimate an installed system cost premium of $\$0.26$/WDC (25%) for 10-MWDC fixed-tilt FPV systems, compared with ground-mounted, fixed-tilt PV installed over bare ground. Higher structural costs related to the floats and anchoring system are the largest contributors to this premium. Currently, site investigation costs are also higher for FPV because of the additional effort needed to plan and design these more complex installations. Our preliminary sensitivity analysis shows that the installed cost of FPV systems is most sensitive to float costs, wind and snow loading, and module efficiency. FPV deployment is in an early stage, and additional experience, best practice development, and new configurations and technologies could help reduce the costs of FPV systems over time.

14 SOLAR ENERGY↗

Space Station Freedom electrical performance model

The baseline Space Station Freedom electric power system (EPS) employs photovoltaic (PV) arrays and nickel hydrogen (NiH2) batteries to supply power to housekeeping and user electrical loads via a direct current (dc) distribution system. The EPS was originally designed for an operating life of 30 years through orbital replacement of components. As the design and development of the EPS continues, accurate EPS performance predictions are needed to assess design options, operating scenarios, and resource allocations. To meet these needs, NASA Lewis Research Center (LeRC) has, over a 10 year period, developed SPACE (Station Power Analysis for Capability Evaluation), a computer code designed to predict EPS performance. This paper describes SPACE, its functionality, and its capabilities.

Hojnicki, Jeffrey S.↗

Q1 2023 U.S. Solar Photovoltaic System and Energy Storage Cost Benchmarks With Minimum Sustainable Price Analysis Data File

The U.S. Department of Energy's (DOE's) Solar Energy Technologies Office (SETO) aims to accelerate the advancement and deployment of solar technology in support of an equitable transition to a decarbonized economy no later than 2050, starting with a decarbonized power sector by 2035. Its approach to achieving this goal includes driving innovations in technology, hardware, and soft cost reductions to make solar affordable and accessible for all. As part of this effort, SETO must track solar cost trends so it can focus its research and development (R&D) on the highest-impact activities. The benchmarks in this report are bottom-up cost estimates of all major inputs to PV and energy storage system installations. Bottom-up costs are based on national averages and do not necessarily represent typical costs in all local markets. Like last year's report, this year's report includes two distinct sets of benchmarks: minimum sustainable price (MSP) benchmarks and modeled market price (MMP) benchmarks. MSP benchmarks can be interpreted as the minimum price a company needs to charge to remain financially solvent in the long term based on the minimum sustainable prices of all inputs including minimum sustainable profit margins. MMP benchmarks can be interpreted as the actual cash sales price a company charges in the given benchmark period. These simplified estimates are useful for tracking technological progress, but they do not reflect all experiences. In fact, no individual estimate under any approach can reflect the diversity of the PV and storage manufacturing and installation industries.

14 SOLAR ENERGY↗

Water Impacts of High Solar PV Electricity Penetration

This analysis provides a detailed national and regional description of the water-related impacts and constraints of high solar electricity penetration scenarios in the U.S. in 2030 and 2050. A modified version of the Regional Energy Deployment System (ReEDS) model that incorporates water resource availability and costs as a constraint in each of its 134 Balancing Area (BA) regions was utilized to explore national and regional differences in water use impacts and solar deployment locations under different solar energy cost and water availability scenarios (Macknick et al. 2015). Water resource availability and cost data are from recently completed research at Sandia National Laboratories (Tidwell et al. 2013a). Scenarios analyzed include two business-as-usual solar energy cost cases, one with and one without considering available water resources, and four solar energy cost cases that meet the SunShot cost goals (i.e., $1/watt for utility-scale PV systems), with varying levels of water availability restrictions. This analysis provides insight into the role solar energy technologies have in the broader electricity sector under scenarios of water constraints.

14 SOLAR ENERGY↗

Risk-Informed Condition Evaluation of Solar-centered Energy Generation and Distribution Networks through Bayesian Learning and Inference

We develop a methodology based on Bayesian inference over Probabilistic Graphical Models (PGMs) to understand and quantify risk in solar-centered grids using targeted measurements and learned system behavior. Being non-prescriptive but, rather, able to infer system behavior and, ultimately, address risk queries from data, our machine learning-type paradigm is tailored for diverse topologies and threat scenarios often associated with distributed energy generation and photovoltaic distributed energy resources (PV-DERs) in particular. We describe algorithmic processes for: (i) learning the structure of PGMs that result from attack-prone PV-DER-proliferated distribution systems, (ii) quantifying cause-effect relationships, and (iii) evaluating risk queries based on diverse evidence. The contributions are illustrated on a residential grid subject to output impairment attacks on its PV-DER infrastructure.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analysis to Inform CA Grid Integration Rules for PV: Final Report on Inverter Settings for Transmission and Distribution System Performance

The fourth solicitation of the California Solar Initiative (CSI) Research, Development, Demonstration and Deployment (RD&D) Program established by the California Public Utilities Commission (CPUC) supported the Electric Power Research Institute (EPRI), National Renewable Energy Laboratory (NREL), and Sandia National Laboratories (SNL) with data provided from Pacific Gas and Electric (PG&E), Southern California Edison (SCE), and San Diego Gas and Electric (SDG&E) conducted research to determine optimal default settings for distributed energy resource advanced inverter controls. The inverter functions studied are aligned with those developed by the California Smart Inverter Working Group (SIWG) and those being considered by the IEEE 1547 Working Group. The advanced inverter controls examined to improve the distribution system response included power factor, volt-var, and volt-watt. The advanced inverter controls examined to improve the transmission system response included frequency and voltage ride-through as well as Dynamic Voltage Support. This CSI RD&D project accomplished the task of developing methods to derive distribution focused advanced inverter control settings, selecting a diverse set of feeders to evaluate the methods through detailed analysis, and evaluating the effectiveness of each method developed. Inverter settings focused on the transmission system performance were also evaluated and verified. Based on the findings of this work, the suggested advanced inverter settings and methods to determine settings can be used to improve the accommodation of distributed energy resources (PV specifically). The voltage impact from PV can be mitigated using power factor, volt-var, or volt-watt control, while the bulk system impact can be improved with frequency/voltage ride-through.

14 SOLAR ENERGY↗

Data-Driven Day-Ahead PV Estimation Using Autoencoder-LSTM and Persistence Model

Inherent variability in photovoltaic (PV) and associated impacts on power systems is a challenging problem for both the PV owners and the grid operators. Existing statistical and machine learning algorithms typically work well for weather conditions similar to historical data. Furthermore, uncertain weather conditions pose a great challenge to the estimation accuracy of the estimation models. With the enhanced integration of intelligent electronic devices and the realization of associated automation in the power grid, renewable energy data is becoming more accessible, which can be utilized by deep learning models and improve the PV power generation estimation accuracy. In this paper, a hybrid deep learning model driven by external weather data is proposed to do day-ahead PV output forecasting at 15-minute-interval. The proposed model is motivated by the recent advancement of Long-Short-Term-Memory (LSTM) networks and AutoEncoder (AE), which estimates uncertainties in sequence while making the prediction for complex weather conditions. Meanwhile, the persistence model (PM) is used to predict continuous sunny weather conditions. The forecasting result is validated with data from multiple locations

42 ENGINEERING↗

Advanced Photovoltaic Inverter Control Development and Validation in a Controller-Hardware-in-the-Loop Test Bed

Penetration of solar photovoltaic (PV) installations into the grid has increased in recent years. In the past, photovoltaic installations have not included grid-support functionality. Grid support functions including Volt-VAR (VVAR), Frequency-Watt (FW), Volt-Watt (VW), frequency/voltage-ride through, as well as other inverter functions such as anti-islanding are recommended by standards such as IEEE 1547 to allow PV inverters to contribute to acceptable operation and stability of distribution systems with high penetrations of PV and to ensure predictable response of the PV inverters. First, low-level and high-level grid support inverter control functions were developed and tested in simulation. The developed controller is able to integrate advanced controller functions in a coordinated approach, avoiding any conflict between the different control objectives. The algorithms were then programmed on an off-the-shelf embedded controller that included a dual-core CPU and FPGA. The details of the high-level grid support function and the lower level switching control will be presented. Second, this programmed controller is tested using a controller-hardware-in-the-loop (CHIL) test bed setup using an FPGA-based real-time simulator. The CHIL setup has the capability to run at a 500 nano-second time-step to accommodate the 20 kHz switching frequency of the developed controller. The advanced control function and CHIL test bed details provided here will aide future researchers to design, implement, and test advanced inverter functions for PV inverters.

14 SOLAR ENERGY↗

InGaP/GaAs Inverted Dual Junction Solar Cells For CPV Applications Using Metal-Backed Epitaxial Lift-Off

The epitaxial lift-off (ELO) technique has been combined with inverted III-V PV cell epitaxial growth with the aim of employing thin film PV cells in HCPV systems. In a stepwise approach to the realization of an inverted triple junction on a MELO platform we have first grown a GaAs single junction PV cell to establish the basic layer release process and cell processing steps followed by the growth, fabrication and test of an inverted InGaP/GaAs dual junction structure.

36 MATERIALS SCIENCE↗

Distributed PV Hosting Capacity Evaluation Considering Equitable PV Accommodation: Preprint

In distribution systems, distributed photovoltaic (DPV) hosting capacity is widely used by system operators to evaluate how much DPV the distribution networks can accommodate without violating operational constraints. With the proliferation of DPV deployment, if managed properly, it offers a great opportunity to mitigate the persistent energy inequity issue in electric grid. Otherwise, energy inequity can be exacerbated with unequal DPV access when hosting capacity improvement plans ignore the equity factor. To consider energy equity in distribution network planning for enhancing DPV accommodation, the hosting capacity evaluation should be improved to consider equity constraints endogenously. In this paper, a DPV hosting capacity evaluation method is proposed considering equitable DPV access among sub-regions of a distribution feeder partitioned by social-economic indicators such as the income levels. The results demonstrate that considering equity in DPV hosting capacity evaluation can provide valuable reference in the equitable energy transition. This work provides a valuable guidance for future distribution network upgrade planning for equitable DPV deployment.

distributed PV↗

A Conservative Approach to Defining Photovoltaic System Hazards to Firefighters

Sandia National Laboratories performed analysis to develop conservative hazard guidelines regarding firefighters working near photovoltaic (PV) arrays. Assuming implementation of NFPA 70 system shutdown requirements, the analysis focused on DC hazards only. Several different PV variables were considered, including system grounding and DC voltage classes. The hazard scenarios considered the contact conditions, current paths through the body, and PPE. Guidelines for the hazard definitions for men and women were based on the IEC TS 60479-1 guidelines. The importance of PPE was illustrated in the results.

14 SOLAR ENERGY↗

Experimental investigation and modeling of a direct-coupled PV/T air collector

Photovoltaic/thermal (PV/T) systems refer to the integration of photovoltaic and solar thermal technologies into one single system, in that both useful heat energy and electricity are produced. The impetus of this paper is to model a direct-coupled PV/T air collector which is designed, built, and tested at a geographic location of Kerman, Iran. In this system, a thin aluminum sheet suspended at the middle of air channel is used to increase the heat exchange surface and consequently improve heat extraction from PV panels. This PV/T system is tested in natural convection and forced convection (with two, four and eight fans operating) and its unsteady results are presented in with and without glass cover cases. A theoretical model is developed and validated against experimental data, where good agreement between the measured values and those calculated by the simulation model were achieved. Comparisons are made between electrical performance of the different modes of operation, and it is concluded that there is an optimum number of fans for achieving maximum electrical efficiency. Also, results show that setting glass cover on photovoltaic panels leads to an increase in thermal efficiency and decrease in electrical efficiency of the system. (author)

14 SOLAR ENERGY↗

Refine your search to explore more results.