Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PHASE ERROR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

An error-controlled adaptive time-stepping method for particle advancement in coupled CFD-DEM simulations

Coupled Computational-Fluid-Dynamics (CFD) and Discrete-Element-Method (DEM) models provide an accurate description of multiphase physical systems where a solid granular particle phase exists in an underlying gaseous continuous medium. The time integration of the granular phase in these simulations is typically handled using an explicit scheme with a constant time-step among all particles that is invariant in time to resolve inter-particle collisions. A locally third-order accurate adaptive time integration technique for particles that employs an embedded locally second-order scheme for error determination is presented in this work. The particle time-step size is dynamically adapted based on solution error, thus leading to significant savings in computational time. The efficacy of our scheme is quantified using four test cases of varying complexity (binary collision, homogeneous cooling system, fluidized bed and hopper discharge). The adaptive time-stepping method exhibits improved performance (~ 2–3 times in most of the cases studied) compared to three commonly used non-adaptive time-step methods (first-order Euler-explicit, second-order Adams-Bashforth and third-order Runge-Kutta schemes), while maintaining the same level of accuracy and parallel scalability.

42 ENGINEERING↗

Clinical benefits of new immobilization system for hypofractionated radiotherapy of intrahepatic hepatocellular carcinoma by helical tomotherapy

Objective: A comprehensive clinical evaluation was conducted, assessing the Body Pro-Lok immobilization and positioning system to facilitate hypofractionated radiotherapy of intrahepatic hepatocellular carcinoma (HCC), using helical tomotherapy to improve treatment precision. Methods: Clinical applications of the Body Pro-Lok system were investigated (as above) in terms of interfractional and intrafractional setup errors and compressive abdominal breath control. To assess interfractional setup errors, a total of 42 patients who were given 5 to 20 fractions of helical tomotherapy for intrahepatic HCC were analyzed. Overall, 15 patients were immobilized using simple vacuum cushion (group A), and the Body Pro-Lok system was used in 27 patients (group B), performing megavoltage computed tomography (MVCT) scans 196 times and 435 times, respectively. Pretreatment MVCT scans were registered to the planning kilovoltage computed tomography (KVCT) for error determination, and group comparisons were made. To establish intrafractional setup errors, 17 patients with intrahepatic HCC were selected at random for immobilization by Body Pro-Lok system, undergoing MVCT scans after helical tomotherapy every week. A total of 46 MVCT re-scans were analyzed for this purpose. In researching breath control, 12 patients, randomly selected, were immobilized by Body Pro-Lok system and subjected to 2-phase 4-dimensional CT (4DCT) scans, with compressive abdominal control or in freely breathing states, respectively. Respiratory-induced liver motion was then compared. Results: Mean interfractional setup errors were as follows: (1) group A: X, 2.97 ± 2.47 mm; Y, 4.85 ± 4.04 mm; and Z, 3.77 ± 3.21 mm; pitch, 0.66 ± 0.62°; roll, 1.09 ± 1.06°; and yaw, 0.85 ± 0.82°; and (2) group B: X, 2.23 ± 1.79 mm; Y, 4.10 ± 3.36 mm; and Z, 1.67 ± 1.91 mm; pitch, 0.45 ± 0.38°; roll, 0.77 ± 0.63°; and yaw, 0.52 ± 0.49°. Between-group differences were statistically significant in 6 directions (p < 0.05). Mean intrafractional setup errors with use of the Body Pro-Lok system were as follows: X, 0.41 ± 0.46 mm; Y, 0.86 ± 0.80 mm; Z, 0.33 ± 0.44 mm; and roll, 0.12 ± 0.19°. Mean liver-induced respiratory motion determinations were as follows: (1) abdominal compression: X, 2.33 ± 1.22 mm; Y, 5.11 ± 2.05 mm; Z, 2.13 ± 1.05 mm; and 3D vector, 6.22 ± 1.94 mm; and (2) free breathing: X, 3.48 ± 1.14 mm; Y, 9.83 ± 3.00 mm; Z, 3.38 ± 1.59 mm; and 3D vector, 11.07 ± 3.16 mm. Between-group differences were statistically different in 4 directions (p < 0.05). Conclusions: The Body Pro-Lok system is capable of improving interfractional and intrafractional setup accuracy and minimizing tumor movement owing to respirations in patients with intrahepatic HCC during hypofractionated helical tomotherapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

A method for simultaneous linear optics and coupling correction for storage rings with turn-by-turn beam position monitor data

We propose a method to simultaneously correct linear optics errors and linear coupling for storage rings using turn-by-turn (TbT) beam position monitor (BPM) data. The independent component analysis (ICA) method is used to isolate the betatron normal modes from the measured TbT BPM data. The betatron amplitudes and phase advances of the projections of the normal modes on the horizontal and vertical planes are then extracted, which, combined with dispersion measurement, are used to fit the lattice model. The fitting results are used for lattice correction. The method has been successfully demonstrated on the NSLS-II storage ring.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Synthesis and Processing by Design of High-Nickel Cathode Materials

The high demand of lightweight, high energy density batteries for energy storage promotes new materials discovery and development. Despite the large number of battery materials being discovered, very few of them have been commercially deployed, mostly bottlenecked by synthesis and processing – namely, making certain phases with the desired structure and properties to meet the multifaceted performance requirements. Alternative to the traditional trial and error, we present here an in situ study aided synthesis- and processing-by-design approach. With specific examples, we illustrate how to use the approach to identify reaction pathways in synthesis and processing of high-Nickel (Ni) cathode materials for next-generation lithium-ion batteries, thereby ensuring precise control of their structure, morphology, and surface properties. Furthermore, perspectives are provided on the wide applicability of the approach to solving critical issues inherent to high-Ni cathodes and the new directions and opportunities in the area.

36 MATERIALS SCIENCE↗

Design of XPM based all optical contention detection circuit at 120 Gbps

This paper presents the design approach of all optical contention detection circuit based on the cross phase modulation interaction between two copropagating signal inside highly nonlinear fiber at the data rate of 120 Gbps. The error free operation has been achieved with the optimized signal power, length and effective area of optical fiber.

42 ENGINEERING↗

Regarding the Main Spectral Lines of a Two-dimensional Two-Electron Atom

The energy of a two-dimensional two-electron atom is calculated in its lowest excited states; together with the previously calculated energy in the ground state, this makes it possible to find the screening constant σ in the lowest excited state and the fundamental frequencies of radiation of such atoms (for example, Не), which can, in principle, be obtained in the Bose condensate phase as has already been done with Na atoms. The possibility of experimental verification of the results is indicated. Errors incurred by other authors in their calculations of σ in the excited state of the two-dimensional He atom are also pointed out.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

CHROMIUM ISOTOPE SYSTEMATICS OF ACHONDRITES: CHRONOLOGY AND ISOTOPIC HETEROGENEITY OF THE INNER SOLAR SYSTEM BODIES

The standard planetary formation models assume that primitive materials, such as carbonaceous chondrites, are the precursor materials of evolved planetesimals. Past chronological studies have revealed that planetesimals of several hundred kilometers in size, such as the Howardite-Eucrite-Diogenite (HED) parent body (Vesta) and angrite parent body, began their differentiation as early as {approx}3 million years of the solar system formation, and continued for at least several million years. However, the timescale of planetesimal formation in distinct regions of the inner solar system, as well as the isotopic characteristics of the reservoirs from which they evolved, remains unclear. Here we present the first report for the precise {sup 53}Mn-{sup 53}Cr ages of monomict ureilites. Chemically separated phases from one monomict ureilite (NWA 766) yielded the Mn-Cr age of 4564.60 {+-} 0.67 Ma, identical within error to the oldest age preserved in other achondrites, such as angrites and eucrites. The {sup 54}Cr isotopic data for this and seven additional bulk ureilites show homogeneous {epsilon}{sup 54}Cr of {approx}-0.9, a value distinct from other achondrites and chondrites. Using the {epsilon}{sup 54}Cr signatures of Earth, Mars, and Vesta (HED), we noticed a linear decrease in the {epsilon}{sup 54}Cr value with the heliocentric distance in the inner region of the solar system. If this trend can be extrapolated into the outer asteroid belt, the {epsilon}{sup 54}Cr signatures of monomict ureilites will place the position of the ureilite parent body at {approx}2.8 AU. These observations imply that the differentiation of achondrite parent bodies began nearly simultaneously at {approx}4565 Ma in different regions of the inner solar system. The distinct {epsilon}{sup 54}Cr value between ureilite and carbonaceous chondrite also implies that a genetic link commonly proposed between the two is unlikely.

79 ASTRONOMY AND ASTROPHYSICS↗

REANALYSIS OF F-STATISTIC GRAVITATIONAL-WAVE SEARCHES WITH THE HIGHER CRITICISM STATISTIC

We propose a new method of gravitational-wave detection using a modified form of higher criticism, a statistical technique introduced by Donoho and Jin. Higher criticism is designed to detect a group of sparse, weak sources, none of which are strong enough to be reliably estimated or detected individually. We apply higher criticism as a second-pass method to synthetic F-statistic and C-statistic data for a monochromatic periodic source in a binary system and quantify the improvement relative to the first-pass methods. We find that higher criticism on C-statistic data is more sensitive by {approx}6% than the C-statistic alone under optimal conditions (i.e., binary orbit known exactly) and the relative advantage increases as the error in the orbital parameters increases. Higher criticism is robust even when the source is not monochromatic (e.g., phase-wandering in an accreting system). Applying higher criticism to a phase-wandering source over multiple time intervals gives a {approx}> 30% increase in detectability with few assumptions about the frequency evolution. By contrast, in all-sky searches for unknown periodic sources, which are dominated by the brightest source, second-pass higher criticism does not provide any benefits over a first-pass search.

79 ASTRONOMY AND ASTROPHYSICS↗

Metal-poor stars observed with the Magellan telescope. II. Discovery of four stars with [Fe/H] ≤ –3.5

We report on the discovery of seven low-metallicity stars selected from the Hamburg/ESO Survey, six of which are extremely metal-poor (EMP, [Fe/H] ≤ –3.0), with four having [Fe/H] ≤ –3.5. Chemical abundances or upper limits are derived for these stars based on high-resolution (R ∼ 35,000) Magellan/MIKE spectroscopy, and are in general agreement with those of other very and extremely metal-poor stars reported in the literature. Accurate metallicities and abundance patterns for stars in this metallicity range are of particular importance for studies of the shape of the metallicity distribution function of the Milky Way's halo system, in particular for probing the nature of its low-metallicity tail. In addition, taking into account suggested evolutionary mixing effects, we find that six of the program stars (with [Fe/H] ≤ –3.35) possess atmospheres that were likely originally enriched in carbon, relative to iron, during their main-sequence phases. These stars do not exhibit overabundances of their s-process elements, and hence may be, within the error bars, additional examples of the so-called CEMP-no class of objects.

79 ASTRONOMY AND ASTROPHYSICS↗

Holographic phase retrieval and reference design

Here, a general mathematical framework and recovery algorithm is introduced for the holographic phase retrieval problem. In this problem, which arises in holographic coherent diffraction imaging, a 'reference' portion of the signal to be recovered via phase retrieval is a priori known from experimental design. A generic formula is additionally derived for the expected recovery error when the measurement data is corrupted by Poisson shot noise. This facilitates an optimization perspective towards reference design and analysis. We employ this optimization perspective towards quantifying the performance of various reference choices.

97 MATHEMATICS AND COMPUTING↗

Accuracy of first-principles interatomic interactions and predictions of ferroelectric phase transitions in perovskite oxides: Energy functional and effective Hamiltonian

While first-principles density functional theory (DFT)-based models have been effective in capturing the physics of ferroelectric phase transitions in BaTiO 3 , PbTiO 3 , and KNbO 3 , quantitative estimates of the transition temperatures (T C ) have errors that are believed to originate from the errors in estimating lattice constants obtained within the local density approximation (LDA) and generalized gradient approximation (GGA) of DFT. The recently developed strongly constrained and appropriately normed (SCAN) meta-GGA functional has been shown to be quite accurate in the estimation of lattice constants. Here, we present a quantitative analysis of the estimates of ferroelectric ground-state properties of eight perovskite oxides and transition temperatures of BaTiO 3 , PbTiO 3 , and KNbO 3 obtained with molecular dynamics simulations using an effective Hamiltonian derived from the SCAN meta-GGA-based DFT. Relative to LDA, we find an improvement in the estimates of T C , which arises from the changes in the calculated strain-phonon, anharmonic coupling constants, and strength of ferroelectric instabilities, i.e., frequencies of the soft modes. We also assess the errors in T C originating from approximately integrating out the high-energy phonons during construction of the model Hamiltonian through estimates of the effects of fourth-order couplings between the soft mode and higher-energy modes of BaTiO 3 , PbTiO 3 , and KNbO 3 . We find that inclusion of these anharmonic couplings results in deeper double-well energy functions of ferroelectric distortions and further improvement in the estimates of transition temperatures. Consistently improved estimates of lattice constants and transition temperatures with the SCAN meta-GGA calculations augur well for their use in simulations of superlattices or heterostructures of perovskite oxides, in which the effects of lattice matching are critical.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Towards Quantum Computing Phase Diagrams of Gauge Theories with Thermal Pure Quantum States

The phase diagram of strong interactions in nature at finite temperature and chemical potential remains largely theoretically unexplored due to inadequacy of Monte-Carlo–based computational techniques in overcoming a sign problem. Quantum computing offers a sign-problem-free approach, but evaluating thermal expectation values is generally resource intensive on quantum computers. To facilitate thermodynamic studies of gauge theories, we propose a generalization of the thermal-pure-quantum-state formulation of statistical mechanics applied to constrained gauge-theory dynamics, and numerically demonstrate that the phase diagram of a simple low-dimensional gauge theory is robustly determined using this approach, including mapping a chiral phase transition in the model at finite temperature and chemical potential. Quantum algorithms, resource requirements, and algorithmic and hardware error analysis are further discussed to motivate future implementations. Thermal pure quantum states, therefore, may present a suitable candidate for efficient thermal simulations of gauge theories in the era of quantum computing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Analysis of phases in the structure determination of an icosahedral virus

The constraints imposed on structure-factor phases by noncrystallographic symmetry (NCS) allow phase improvement, phase extension to higher resolution and hence ab initio phase determination. The more numerous the NCS redundancy and the greater the volume used for solvent flattening, the greater the power for phase determination. In a case analyzed here the icosahedral NCS phasing appeared to have broken down, although later successful phase extension was possible when the envelope around the NCS region was tightened. The phases from the failed phase-determination attempt fell into four classes, all of which satisfied the NCS constraints. These four classes corresponded to the correct solution, opposite enantiomorph, Babinet inversion and opposite enantiomorph with Babinet inversion. These incorrect solutions can be seeded from structure factors belonging to reciprocal-space volumes that lie close to icosahedral NCS axes where the structure amplitudes tend to be large and the phases tend to be 0 or {pi}. Furthermore, the false solutions can spread more easily if there are large errors in defining the envelope designating the region in which NCS averaging is performed.

58 GEOSCIENCES↗

Dosimetric effects of rotational output variation and x-ray target degradation on helical tomotherapy plans

In this study, two potential sources of IMRT delivery error have been identified for helical tomotherapy delivery using the HiART system (TomoTherapy, Inc., Madison, WI): Rotational output variation and target degradation. The HiArt system is known to have output variation, typically about {+-}2%, due to the absence of a dose servo system. On the HiArt system, x-ray target replacement is required approximately every 10-12 months due to target degradation. Near the end of target life, the target thins and causes a decrease in the beam energy and a softening of the beam profile at the lateral edges of the beam. The purpose of this study is to evaluate the dosimetric effects of rotational output variation and target degradation by modeling their effects and incorporating them into recalculated treatment plans for three clinical scenarios: Head and neck, partial breast, and prostate. Models were created to emulate both potential sources of error. For output variation, a model was created using a sine function to match the amplitude ({+-}2%), frequency, and phase of the measured rotational output variation data. A second model with a hypothetical variation of {+-}7% was also created to represent the largest variation that could exist without violating the allowable dose window in the delivery system. A measured beam profile near the end of target life was used to create a modified beam profile model for the target degradation. These models were then incorporated into the treatment plan by modifying the leaf opening times in the delivery sinogram. A new beam model was also created to mimic the change in beam energy seen near the end of target life. The plans were then calculated using a research version of the PLANNED ADAPTIVE treatment planning software from TomoTherapy, Inc. Three plans were evaluated in this study: Head and neck, partial breast, and prostate. The D{sub 50} of organs at risk, the D{sub 95} for planning target volumes (PTVs), and the local dose difference were used to evaluate the changes in the modified treatment plans. Dosimetric effects from rotational variation were found to be low (less than 1%) for a typical variation of {+-}2%. Even using a variation of {+-}7%, DVH values and dose distributions were altered by less than 2% for all scenarios. The dosimetric effects of target degradation were found to be slightly more significant. For a model using data taken just before target failure, dosimetric differences of 2%-4% were observed in the recalculated plans when compared to the original plans. The largest effects (up to 4.5%) were observed for PTVs that were located at deeper depths as seen in the prostate plan. Overall, the recalculated plans show that the dosimetric effects of rotational variation and target degradation are on the order of 1%-4% for helical tomotherapy on the HiART system and do not pose a risk for significant deviations from the original treatment plan.

61 RADIATION PROTECTION AND DOSIMETRY↗

Respiratory effort correction strategies to improve the reproducibility of lung expansion measurements

Purpose: Four-dimensional computed tomography (4DCT) can be used to make measurements of pulmonary function longitudinally. The sensitivity of such measurements to identify change depends on measurement uncertainty. Previously, intrasubject reproducibility of Jacobian-based measures of lung tissue expansion was studied in two repeat prior-RT 4DCT human acquisitions. Difference in respiratory effort such as breathing amplitude and frequency may affect longitudinal function assessment. In this study, the authors present normalization schemes that correct ventilation images for variations in respiratory effort and assess the reproducibility improvement after effort correction.Methods: Repeat 4DCT image data acquired within a short time interval from 24 patients prior to radiation therapy (RT) were used for this analysis. Using a tissue volume preserving deformable image registration algorithm, Jacobian ventilation maps in two scanning sessions were computed and compared on the same coordinate for reproducibility analysis. In addition to computing the ventilation maps from end expiration to end inspiration, the authors investigated the effort normalization strategies using other intermediated inspiration phases upon the principles of equivalent tidal volume (ETV) and equivalent lung volume (ELV). Scatter plots and mean square error of the repeat ventilation maps and the Jacobian ratio map were generated for four conditions: no effort correction, global normalization, ETV, and ELV. In addition, gamma pass rate was calculated from a modified gamma index evaluation between two ventilation maps, using acceptance criterions of 2 mm distance-to-agreement and 5% ventilation difference.Results: The pattern of regional pulmonary ventilation changes as lung volume changes. All effort correction strategies improved reproducibility when changes in respiratory effort were greater than 150 cc (p < 0.005 with regard to the gamma pass rate). Improvement of reproducibility was correlated with respiratory effort difference (R = 0.744 for ELV in the cohort with tidal volume difference greater than 100 cc). In general for all subjects, global normalization, ETV and ELV significantly improved reproducibility compared to no effort correction (p = 0.009, 0.002, 0.005 respectively). When tidal volume difference was small (less than 100 cc), none of the three effort correction strategies improved reproducibility significantly (p = 0.52, 0.46, 0.46 respectively). For the cohort (N = 13) with tidal volume difference greater than 100 cc, the average gamma pass rate improves from 57.3% before correction to 66.3% after global normalization, and 76.3% after ELV. ELV was found to be significantly better than global normalization (p = 0.04 for all subjects, and p = 0.003 for the cohort with tidal volume difference greater than 100 cc).Conclusions: All effort correction strategies improve the reproducibility of the authors' pulmonary ventilation measures, and the improvement of reproducibility is highly correlated with the changes in respiratory effort. ELV gives better results as effort difference increase, followed by ETV, then global. However, based on the spatial and temporal heterogeneity in the lung expansion rate, a single scaling factor (e.g., global normalization) appears to be less accurate to correct the ventilation map when changes in respiratory effort are large.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A0535+26 - Refined position measurement and new pulse period data

The hard, pulsing, transient X-ray source A0535+26 has been observed with SAS 3 on three occasions during 1977-1978. These observations have yielded a precise position measurement (20 arcsec error radius), which renders the identification of A0535+26 with the Be star HDE 245770 virtually certain. The pulse phase was tracked for about 9 days in April 1978 and clearly showed both first and second derivatives in the pulse period. An analysis of these timing data, combined with data from previous observations, leads to the following conclusions: (1) a significant fraction of the observed changes in pulse period is probably intrinsic to the compact X-ray star (e.g., accretion torques on a neutron star), and (2) conservative limits on binary orbital parameters tend to further confirm a long orbital period (at least about 20 days).

Li, F.↗

Terminal area automatic navigation, guidance, and control research using the Microwave Landing System (MLS). Part 2: RNAV/MLS transition problems for aircraft

The problems in navigation and guidance encountered by aircraft in the initial transition period in changing from distance measuring equipment, VORTAC, and barometric instruments to the more precise microwave landing system data type navaids in the terminal area are investigated. The effects of the resulting discontinuities on the estimates of position and velocity for both optimal (Kalman type navigation schemes) and fixed gain (complementary type) navigation filters, and the effects of the errors in cross track, track angle, and altitude on the guidance equation and control commands during the critical landing phase are discussed. A method is presented to remove the discontinuities from the navigation loop and to reconstruct an RNAV path designed to land the aircraft with minimal turns and altitude changes.

Pines, S.↗

Design and Performance of Sampled Data Loops for Subcarrier and Carrier Tracking

Design parameters and resulting performance are presented for the sampled data analogies of continuous time phase locked loops of second and third order containing perfect integrators. Expressions for noise equivalent bandwidth and steady state errors are given. Stability and gain margin are investigated using z plane root loci. Finally, an application is presented for Voyager subcarrier and carrier tracking under the dynamics of the encounters with Uranus and Neptune. For carrier tracking, loop bandwidth narrow enough for satisfactory loop signal to noise ratios can be achieved using third order loops without rate aiding, whereas second order loops would require aiding. For subcarrier tracking, third order loops can be used when the sampling rate is limited to approximately once per second, as in the Baseband Assembly, whereas second order loops sufficiently wide to track the dynamics have stability problems at that sampling rate.

Aguirre, S.↗

Refine your search to explore more results.