Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Off Gas”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Expansion of a Superfluid Fermi Gas Monolayer

A monolayer of superfluid Fermi gas can be prepared within an optical dipole trap using the tight confinement along the chosen direction. In this case, Cooper pairs occupy the lowest state corresponding to the motion in the trapping potential. After switching off the trapping potential, the initially two-dimensional gas expands to the three-dimensional space. In the case of unitary s-wave interactions, the dynamics of Fermi gas expansion is treated in the framework of appropriately modified Gross–Pitaevskii equation. It is found that the superfluid gas expands significantly faster than the normal gas, in contrast to the situation characteristic of the initially three-dimensional gas. The available experimental data [P. Dyke et al., Phys. Rev. A 93, 011603 (2016)] are close to the predictions of the model under study.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The use of partial fuel stratification to enable stable ultra-lean deflagration-based Spark-Ignition engine operation with controlled end-gas autoignition of gasoline and E85

Lean operation of Spark-Ignition engines can provide higher thermal efficiency compared to standard stoichiometric operation. However, for a homogeneous lean mixture, the associated reduction of flame speeds becomes an important issue from the perspective of robust ignition and fast flame spread throughout the charge. This study is focused on the use of a lean partial fuel stratification strategy that can stabilize the deflagration, while sufficiently fast combustion is ensured via the use of end-gas autoignition. The engine has a spray-guided Direct-Injection Spark-Ignition combustion system and was fueled with either a high-octane certification gasoline or E85. Partial fuel stratification was achieved using several fuel injections during the intake stroke in combination with a small pilot-injection concurrent with the Spark-Ignition. The results reveal that partial fuel stratification enables very stable combustion, offering higher thermal efficiency for parts of the load range in comparison to well-mixed lean and stoichiometric combustion. The heat release and flame imaging demonstrate that the combustion often has three distinct stages. The combustion of the pilot-injected fuel, ignited by the normal spark, acts as a “super igniter,” ensuring a very repeatable initiation of combustion, and flame incandescence reveals locally rich conditions. The second stage is mainly composed of blue flame propagation in a well-mixed lean mixture. The third stage is the compression autoignition of a well-mixed and typically very lean end-gas. The end-gas autoignition is critical for achieving high combustion efficiency, high thermal efficiency, and stable combustion. Partial fuel stratification enables very effective combustion-phasing control, which is critical for controlling the occurrence and intensity of end-gas autoignition. Comparing the gasoline and E85 fuels, it is noted that achieving end-gas autoignition for the higher octane E85 requires a more aggressive compression of the end-gas via the use of a more advanced combustion phasing or higher intake-air temperature.

33 ADVANCED PROPULSION SYSTEMS↗

Learning reference governor for cycle-to-cycle combustion control with misfire avoidance in spark-ignition engines at high exhaust gas recirculation–diluted conditions

Cycle-to-cycle feedback control is employed to achieve optimal combustion phasing while maintaining high levels of exhaust gas recirculation by adjusting the spark advance and the exhaust gas recirculation valve position. The control development is based on a control-oriented model that captures the effects of throttle position, exhaust gas recirculation valve position, and spark timing on the combustion phasing. Under the assumption that in-cylinder pressure information is available, an adaptive extended Kalman filter approach is used to estimate the exhaust gas recirculation rate into the intake manifold based on combustion phasing measurements. The estimation algorithm is adaptive since the cycle-to-cycle combustion variability (output covariance) is not known a priori and changes with operating conditions. A linear quadratic regulator controller is designed to maintain optimal combustion phasing while maximizing exhaust gas recirculation levels during load transients coming from throttle tip-in and tip-out commands from the driver. During throttle tip-outs, however, a combination of a high exhaust gas recirculation rate and an overly advanced spark, product of the dynamic response of the system, generates a sequence of misfire events. In this work, an explicit reference governor is used as an add-on scheme to the closed-loop system in order to avoid the violation of the misfire limit. The reference governor is enhanced with model-free learning which enables it to avoid misfires after a learning phase. Experimental results are reported which illustrate the potential of the proposed control strategy for achieving an optimal combustion process during highly diluted conditions for improving fuel efficiency.

42 ENGINEERING↗

Acoustic sensing and autoencoder approach for abnormal gas detection in a spent nuclear fuel canister mock-up

Currently, spent nuclear fuel (SNF) from commercial nuclear power plants is stored in stainless-steel canisters for interim dry storage. To provide an inert environment, these canisters are backfilled with helium after vacuum drying. However, the helium environment may be contaminated during extended storage because of the material degradation. For example, the heavier fission gas xenon may be released from the fuel rods into the canister cavity should the fuel cladding be breached. Other gases such as air and water vapor may also be present as a result of leakage caused by chloride-induced stress corrosion cracking on the canister walls or by insufficient vacuum drying. Therefore, monitoring the gas composition can provide critical information about the health of SNF canisters. In this study, noninvasive testing was conducted on a 2/3-scaled SNF canister mock-up using acoustic sensing. Ultrasonic transducers were placed on the exterior surface of the canister to probe the gas composition. A dataset was collected by sealing the canister mock-up and introducing up to 1.53% argon or 1.29% air into the helium background gas. Three methods were used to detect changes in the gas composition: the time-of-flight (TOF) method, the differential method, and the autoencoder method. Results showed that the TOF method had sufficient resolution to detect abnormal gas concentrations of less than 1.0%. The differential method demonstrated a periodic in-phase and out-of-phase behavior between the benchmark (i.e., pure helium) and abnormal (i.e., with argon or air) state signals. The variational autoencoder (VAE) and the Wasserstein autoencoder (WAE) were trained on the benchmark data and were applied directly to the abnormal state data. It was found that both the unsupervised VAE and the WAE were able to distinguish the benchmark and abnormal states of the canister mock-up based on the reconstruction error.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Offshore Oil and Gas Infrastructure Reuse for CCS: Opportunities and Challenges in the U.S. Gulf of Mexico

The United States Gulf of Mexico has historically been a significant oil and gas producing region and continues to produce hydrocarbons today. As such, significant investments have been made to install oil and gas infrastructure such as pipelines, platforms, and wells. As these assets reach the end of their useful life or production associated with the assets is curtailed, the assets become a liability for both the owner/operators and the U.S. and state governments responsible for regulating the assets. There are costs and risks associated with safely decommissioning the assets, and in some cases, the assets may be abandoned (e.g., the owner is no longer a going concern). In parallel, carbon capture and storage (CCS) technology has developed in the United States and interest and incentives for CCS projects have accelerated in recent years, with many public announcements of CCS projects in development in the U.S. Gulf of Mexico region. The region is particularly well-suited to CCS due to the high density of industry on the coastline (i.e., CO 2 sources) and favorable geology in the near-offshore region. CCS also requires the use of many of the same assets required for oil and gas production (pipelines, platforms, wells) and the oil and gas industry has direct experience with CO 2 transport and injection (i.e., EOR). Therefore, the combination of existing infrastructure in close proximity to potential CCS project sites appears to provide a potential “win-win” solution for re-use of existing oil and gas assets. This paper presents a high-level evaluation of oil and gas infrastructure in the Gulf of Mexico with the goals of identifying the scale of the opportunity (e.g., how much existing infrastructure is realistically re-usable), identifying gaps in knowledge/policy/information required to evaluate existing infrastructure for re-use, and proposing key actions that could be pursued to further the assessment of existing infrastructure re-use for CCS.

Infrastructure, reuse, re-purpose, oil and gas, pi↗

Closures for Course-Grid Simulation of Fluidized Gas-Particle Flows

Gas-particle flows in fluidized beds and riser reactors are inherently unstable, and they manifest fluctuations over a wide range of length and time scales. Two-fluid models for such flows reveal unstable modes whose length scale is as small as ten particle diameters. Yet, because of limited computational resources, gas-particle flows in large fluidized beds are invariably simulated by solving discretized versions of the two-fluid model equations over a coarse spatial grid. Such coarse-grid simulations do not resolve the small-scale spatial structures which are known to affect the macroscale flow structures both qualitatively and quantitatively. Thus there is a need to develop filtered two-fluid models which are suitable for coarse-grid simulations and capturing the effect of the small-scale structures through closures in terms of the filtered variables. The overall objective of the project is to develop validated closures for filtered two-fluid models for gas-particle flows, with the transport gasifier as a primary, motivating example. In this project, highly resolved three-dimensional simulations of a kinetic theory based two-fluid model for gas-particle flows have been performed and the statistical information on structures in the 100-1000 particle diameters length scale has been extracted. Based on these results, closures for filtered two-fluid models have been constructed. The filtered model equations and closures have been validated against experimental data and the results obtained in highly resolved simulations of gas-particle flows. The proposed project enables more accurate simulations of not only the transport gasifier, but also many other non-reacting and reacting gas-particle flows in a variety of chemical reactors. The results of this study are in the form of closures which can readily be incorporated into existing multi-phase flow codes such as MFIX (www.mfix.org). Therefore, the benefits of this study can be realized quickly. The training provided by this project has prepared a PhD student to enter research and development careers in DOE laboratories or chemicals/energy-related industries.

01 COAL, LIGNITE, AND PEAT↗

Flue gas injection control of silica in cooling towers.

Injection of CO{sub 2}-laden flue gas can decrease the potential for silica and calcite scale formation in cooling tower blowdown by lowering solution pH to decrease equilibrium calcite solubility and kinetic rates of silica polymerization. Flue gas injection might best inhibit scale formation in power plant cooling towers that use impaired makeup waters - for example, groundwaters that contain relatively high levels of calcium, alkalinity, and silica. Groundwaters brought to the surface for cooling will degas CO{sub 2} and increase their pH by 1-2 units, possibly precipitating calcite in the process. Recarbonation with flue gas can lower the pHs of these fluids back to roughly their initial pH. Flue gas carbonation probably cannot lower pHs to much below pH 6 because the pHs of impaired waters, once outgassed at the surface, are likely to be relatively alkaline. Silica polymerization to form scale occurs most rapidly at pH {approx} 8.3 at 25 C; polymerization is slower at higher and lower pH. pH 7 fluids containing {approx}220 ppm SiO{sub 2} require > 180 hours equilibration to begin forming scale whereas at pH 8.3 scale formation is complete within 36 hours. Flue gas injection that lowers pHs to {approx} 7 should allow substantially higher concentration factors. Periodic cycling to lower recoveries - hence lower silica concentrations - might be required though. Higher concentration factors enabled by flue gas injection should decrease concentrate volumes and disposal costs by roughly half.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Gas Hydrate Characterization in the GoM using Marine EM Methods

In spite of the importance of gas hydrate as a low-carbon fuel, a possible contributor to rapid climate change, and a significant natural hazard, our current understanding about the amount and distribution of submarine gas hydrate is somewhat poor; estimates of total volume vary by at least an order of magnitude, and commercially useful concentrations of hydrate have remained an elusive target. This is largely because conventional geophysical tools have intrinsic limitations in their ability to quantitatively image hydrate. It has long been known from well logs that gas hydrate is resistive compared to the host sediments, and electrical and electromagnetic methods have been proposed and occasionally used to image hydrates. This project seeks to expand our capabilities to use electromagnetic methods to explore for gas hydrate in the marine environment. An important basic science aspect of our work was to quantify the resistivity of pure gas hydrate as a function of temperature at seafloor pressures. We designed, constructed, and tested a highpressure cell in which hydrate could be synthesized and then subjected to electrical conductivity measurements. Impedance spectroscopy at frequencies between 20 Hz and 2 MHz was used to separate the effect of the blocking electrodes from the intrinsic conductivity of the hydrate. We obtained very reproducible results that showed that pure methane hydrate was several times more resistive than the water ice that seeded the synthesis, 20,000 {Ohm}m at 0{degrees} C, and that the activation energy is 30.6 kJ/mol over the temperature range of -15 to 15{degrees} C. Adding silica sand to the hydrate, however, showed that the addition of the extra phase caused the conductivity of the assemblage to increase in a counterintuitive way. The fact that the increased conductivity collapsed after a percolation threshold was reached, and that the addition of glass beads does not produce a similar increase in conductivity, together suggest that while the surface of the gas hydrate grains are not intrinsically conductive, the presence of sand does increase their conductivity. In the field component of this project, we carried out an 18day cruise on the R.V. Roger Revelle in the Gulf of Mexico from 7th-26th October 2008 to collect controlled-source electromagnetic (CSEM) data over four hydrate prospects; blocks AC 818, WR 313, GC 955, and MC 118. During these surveys we deployed 30 ocean bottom electromagnetic (OBEM) recorders a total of 94 times at four survey areas and towed the Scripps Undersea Electromagnetic Source Instrument (SUESI) a total of 103 hours. SUESI transmission was 200 A on a 50 m dipole antenna at heights of 70-100 m above the seafloor. We also towed a neutrally buoyant 3-axis electric field recorder behind the SUESI antenna at a constant offset of 300 m. The use of a towed receiver that is "flown" above the seafloor allowed us to operate in areas where seafloor infrastructure such as wellheads, pipelines, and installed scientific equipment existed. We reduced the data to apparent resistivity psuedosections. The most compelling results come from the hydrate observatory at MC 118, where a localized resistivity anomaly is clearly identified under the southeast crater in an otherwise uniform 1 {Ohm}m background. The data from MC 118 also show that authigenic carbonate does not necessarily express itself as a confounding resistor, as was feared at the start of this project. While the results from the other prospects are much more complicated, the data are well correlated with known geology, and line to line agreement is good. Although these data are not amenable to 1D inversion as was initially hoped, we expect to use a newly developed 2D CSEM inversion code to continue to get useful information from this rich data set.

03 NATURAL GAS↗

DUS II Soil Gas Sampling and Air Injection Test Results

Soil vapor extraction (SVE) and air injection well testing was performed at the Dynamic Underground Stripping (DUS) site located near the M-Area Settling Basin (referred to as DUS II in this report). The objective of this testing was to determine the effectiveness of continued operation of these systems. Steam injection ended on September 19, 2009 and since this time the extraction operations have utilized residual heat that is present in the subsurface. The well testing campaign began on June 5, 2012 and was completed on June 25, 2012. Thirty-two (32) SVE wells were purged for 24 hours or longer using the active soil vapor extraction (ASVE) system at the DUS II site. During each test five or more soil gas samples were collected from each well and analyzed for target volatile organic compounds (VOCs). The DUS II site is divided into four parcels (see Figure 1) and soil gas sample results show the majority of residual VOC contamination remains in Parcel 1 with lesser amounts in the other three parcels. Several VOCs, including tetrachloroethylene (PCE) and trichloroethylene (TCE), were detected. PCE was the major VOC with lesser amounts of TCE. Most soil gas concentrations of PCE ranged from 0 to 60 ppmv with one well (VEW-22A) as high as 200 ppmv. Air sparging (AS) generally involves the injection of air into the aquifer through either vertical or horizontal wells. AS is coupled with SVE systems when contaminant recovery is necessary. While traditional air sparging (AS) is not a primary component of the DUS process, following the cessation of steam injection, eight (8) of the sixty-three (63) steam injection wells were used to inject air. These wells were previously used for hydrous pyrolysis oxidation (HPO) as part of the DUS process. Air sparging is different from the HPO operations in that the air was injected at a higher rate (20 to 50 scfm) versus HPO (1 to 2 scfm). . At the DUS II site the air injection wells were tested to determine if air sparging affected VOC soil gas concentrations during ASVE. Five (5) SVE wells that were located closest to the air injection wells were used as monitoring points during the air sparging tests. The air sparging tests lasted 48 hours. Soil gas sample results indicate that sparging did not affect VOC concentrations in four of the five sparging wells, while results from one test did show an increase in soil gas concentrations.

54 ENVIRONMENTAL SCIENCES↗

Impact of Natural Gas Appliances on Pollutant Levels in California Homes

This report presents results from the first year of a 2-year study, investigating associations of five air pollutants (CO, NO 2 , NO X , formaldehyde and acetaldehyde) with the presence of natural gas appliances in California homes. From November 2011 to March 2012, pollutant concentration and occupant activity data were collected in 155 homes for 6-day periods. The sample population included both single-family (68%) and multi-family (32%) dwellings, with 87% having at least one gas appliance and 77% having an unvented gas cooking appliance. The geometric mean (GM) NO 2 levels measured in the kitchen, bedroom and outside of homes were similar at values of 15, 12 and 11 ppb, respectively. In contrast, the GM NO X levels measured in the kitchen and bedroom of homes were much higher than levels measured outdoors, at levels of 42 and 41 ppb, compared to 19 ppb, respectively. Roughly 10% of sampled homes had 6-day average NO2 levels that exceeded the outdoor annual average limit set by the California Ambient Air Quality Standards (CAAQS) (30 ppb). The GMs of the highest 1-h and 8-h CO level measured in homes were 2.5 and 1.1 ppm, respectively. Four homes had a 1-h or 8-h concentration that exceeded the outdoor limits set by the CAAQS. The GM formaldehyde and acetaldehyde concentrations measured in homes were 15 and 7 ppb, respectively. Roughly 95% of homes had average formaldehyde levels indoors that exceeded the Chronic Reference Exposure Level set by the California EPA (7 ppb). Concentrations of NO 2 and NO X , and to a lesser extent CO were associated with use of gas appliances, particularly unvented gas cooking appliances. Based on first principles, it is expected that effective venting of cooking pollutant emissions at the source will lead to a reduction of pollutant concentrations. However, no statistical association was detected between kitchen exhaust fan use and pollutant concentrations in homes in this study where gas cooking occurred frequently. The lack of statistical

03 NATURAL GAS↗

Integrating Magnetotellurics, Soil Gas Geochemistry and Structural Analysis to Identify Hidden, High Enthalpy, Extensional Geothermal Systems

Our research group comprising personnel from University of Utah/EGI (UU/EGI), University of Nevada at Reno (UNR) and Lawrence Berkeley National Laboratory (LBNL) has been applying magnetotellurics (MT), diagnostic structural affiliations, and soil gas flux and geochemistry to assist in identifying hidden, high-enthalpy geothermal systems in extensional regimes of the U.S. Great Basin. We are specifically looking for upwelling low-resistivity and geologic structures that can carry fluids from magmatic or high-grade metamorphic conditions in the deep crust upward to exploitable depths, and to verify the nature of the deep sources through soil gas geochemical compositions. The project was motivated by prior MT transect coverage of western and central Nevada centered upon the Dixie Valley geothermal system where such favorable indicators were first recognized. The high-angle structures are taken to be fluidized fault zones connecting deep magmatic/metamorphic activity with the geothermal system but the concept requires verification by testing at other systems. The project was set up with a two-phased organization. Phase I was carried out at the McGinness Hills system, central Nevada, where Ormat’s flagship power facility is located and a considerable amount of pre-existing data was available. Transect MT data also showed a strong low-resistivity upwelling originating from interpreted deep crustal magmatic underplating. Controlling structures on production as indicated by Ormat data and new mapping by UNR were favorable to dilatency being an accommodation zone between major normal faults of opposing dip. A 3D MT survey and inversion confirmed the existence of the steep low-resistivity zone dipping ESE toward the deep crust and placed N-S bounds upon the feature. Ormat personnel cooperated with PI Wannamaker in the field in providing fluid samples from the production intervals for He isotope composition. Elevated 3He was verified through analysis at LBNL confirming that there was a magmatic connection into the producing system. High CO2 soil gas flux including possibly metamorphic 13C and 14C component was measured over the area of dilatent structures. Hence, the triad of indicators posed above was confirmed in Phase I. Subsequently, Phase II of the project proceeded in the greenfield Kumiva-Blackrock Desert district of northwestern Nevada to see if a new system could be identified. Transect MT data also showed a strong low-resistivity upwelling originating from interpreted deep crustal magmatic underplating. However, given that there was no exploitable geothermal system recognized at the outset in the region, the collection of new geoscientific data was required. An areal MT survey of 131 sites over the Kumiva-Blackrock Desert district was completed, and a 3D inversion produced using the in-house, DOE-supported finite element inversion algorithm. Particular MT low resistivity upwellings that received followup study occurred under the west flank of the Seven Troughs Range, under the playa immediately west of the Blue Wing Mountains, and under northern Granite Springs Valley. Structural assessment of the project area by Co-I J. Faulds at UNR provided numerous favorable Quaternary fault settings, which were correlated to the MT upwelling structures. Extensive profiling for CO2 soil gas flux over favorable geophysical and geological structure was performed by LBNL personnel. Soil gas flux anomalies generally were not large but did show correlation with MT upwelling structure and favorably dilatent geological structures. Isotope analyses showed presence of possible inorganic/metamorphic 13C but 14C concentrations did not exceed background values. We view the initial concept of a confluence of MT low-resistivity upwelling, favorably dilatent 3D geological structure, and elevated soil gas flux including 13C component to be supported by the further evidence of this project although the indicators in the Phase II study were more diffuse. The northern Granite Springs Valley structure is receiving followup in the UNR Play Fairway Analysis, being in the southern termination of a major normal fault with silicified soil and warm temperature probe results

15 GEOTHERMAL ENERGY↗

Approaches for Integrating Renewable Energy Technologies in Oil and Gas Operations

Petroleum (including both oil and gas) heats our homes, drives our transportation system, generates electricity and makes modern life possible. Continued demand from developed countries along with growth from developing economies implies demand for oil and gas will likely continue to be robust. Considering the desire to maximize production efficiency and economic returns, there is increased attention to the fact that nearly 10% of oil is consumed in the process of oil production, transportation and refining (Halabi, et al., 2015), and that a quarter of a barrel of oil is used to produce a barrel of heavy oil (Wesoff, 2015). As oil and gas development shifts to secondary and other non-conventional sources, meeting future demand is anticipated to require substantial amounts of energy to produce, transport and refine petroleum. Increasing efficiency of operations and incorporating energy sources that maximize product revenue while simultaneously addressing local environmental concerns as well as reducing overall greenhouse gas emissions has prompted a growing interest in integrating renewable energy technologies in oil and gas operations. Furthermore, due to dramatic declines in the cost of energy generation from renewable sources, integrating renewable energy technology can in many cases reduce operations costs as well. This report provides an overview of where renewable energy technologies can economically be integrated into oil and gas operations.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

High Efficiency Cost Optimized - Spark Ignited Natural Gas Engines (HECO-SING) (Final Report)

The abundance of relatively low cost natural gas in the North American market, along with energy independence, makes natural gas attractive as an alternate fuel. Natural gas also has an advantage over diesel engines in low NOx emissions production. Natural gas does however have some technical challenges in its lower efficiency due to natural gas energy content in comparison to diesel or gasoline, which is also a partial factor in its vehicle storage capacity limitations and thus driving range. In order to address these challenges, the HECO-SING (High-Efficiency Cost-Optimized, Spark Ignited Natural Gas) project was undertaken. The goal was to increase engine efficiency (fuel economy), while still meeting future emissions, in a cost effective manner. In order to achieve these goals, high dilution combustion will be used with focus on advanced ignition systems, optimized aftertreatment selection, and creative engine controls are applied.

03 NATURAL GAS↗

Measurements of fission gas release from nuclear fuel in support of BISON fuel performance analysis

This project established a fuel irradiation and fission gas release (FGR) loop that has been designed for implementation at the PULSTAR reactor of North Carolina State University (NCSU). The FGR loop is capable of analyzing various types of fuel samples including, e.g., uranium dioxide fuel (UO 2 ) and uranium silicide (U 3 Si 2 ) samples. The fuel samples were produced and characterized at Idaho National Laboratory (INL) and shipped NCSU. The samples are ready for irradiation in the FGR loop to a given total thermal neutron fluence and under controlled temperature conditions. An innovative high resolution gamma-ray spectrometry approach and instrumentation have been established to monitor the loop’s sweep gas and perform high accuracy measurements of the gas release rates relative to predicted birth rates to establish the release-to-birth ratio (R/B) for a given radionuclide. In addition, uncertainty minimization is achieved through the formulation of the measurement observables into relative release-to-birth indicators for selected radionuclides. The experimental findings will be utilized to enhance and validate the fission gas release models that are currently implemented in the BISON fuel performance code. The experimentally deduced physical parameters will be incorporated in BISON’s fission gas release models. Atomistic simulations of fuel behavior have been performed to investigate the mechanisms of fission gas migration in the fuel. At this stage, performance of the fuel irradiation experiments awaits licensing approval by the US NRC.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Emission Inventories from Natural Gas Storage Facilities using Regional Frequency Comb Laser Monitoring and Aircraft Flyovers. Final Report

The project centers around a ground-based regional methane sensor developed by the CU/NIST team members under the DOE ARPA-E MONITOR program, and sophisticated aircraft measurement techniques developed by the UCD/Scientific Aviation team (responsible for a recent Science publication quantifying the Aliso Canyon storage field release). The dual frequency-comb spectrometer is an invisible, eye-safe laser capable of measuring atmospheric methane concentrations along beam paths 1+ miles in length with high precision and stability (<1 ppb methane over 1 mile). The CU/NIST team has developed a unique approach to using a single, central spectrometer to locate and size methane emissions as small as 6 scfh from specific gas field structures within the 1+ mile range of the laser. Deployment involves the stationing of small cubic mirrors at strategic locations across the gas storage site. The mirrors direct light from the spectrometer back to a detector, where methane concentrations are recorded based on light absorption at specific wavelengths. The measurements are coupled with high resolution gas transport models based on meteorological measurements (wind, etc.) to determine the precise location and emission rate of methane sources. The calibration-free and continuous nature of dual frequency-comb spectrometer measurements means that a large area can be monitored continuously for temporal variability of emissions over long periods of time. The aircraft measurements involve spiral flights around storage facilities with a sensitive ethane/methane measurement package. Upwind/downwind concentration comparisons and wind data provide total facility emissions data. During this project, a new micrometeorological package was integrated onto the Scientific Aviation aircraft to provide even greater emissions quantification capability. In this project, the ground-based measurement system was deployed for 11 months (to capture seasonal variability) at a West Coast storage facility, together with a campaign of twice monthly aircraft total facility emissions flights. The data from these two modalities was combined to quantify the methane emissions from the facility with first-of-its-kind temporal and spatial detail. Concurrent with this deployment, the aircraft team performed flights to quantify emissions at a wider array of previously un-surveyed storage sites. The ground-based measurement system was then moved to an additional site of differing total storage and delivery capacity. Aircraft mass balance flights continued, repeatedly surveying (twice monthly) this site, as well as surveying a large number of previously un-assessed sites spanning a variety of size, reservoir type and age. Assessment of ground-based, temporally and spatially detailed methane emissions information alongside aircraft-derived methane total facility emissions information led to an improved understanding of emissions, relevant for inventories of the natural gas storage sector. In particular, this work provided temporal detail (seasonal of emissions and frequency of leaks) to stakeholders and personnel responsible for updates to the EPA’s GHGI. The impact of the proposed work has been a dramatic improvement in the temporal, spatial, and site- and type- specific detail and quantification of emissions inventories for the natural gas storage sector. This work directly benefits the EPA’s GHGI, directly ameliorates the environmental impacts and public health and safety of the natural gas storage sector, and aids policymakers and industry to make sound choices with respect to management and regulation.

03 NATURAL GAS↗

Feb. 2021 Electricity Blackouts and Natural Gas Shortages in Texas

An extreme winter storm and extended cold weather event hit Texas and the central United States February 8–19, 2021. This led to both exceptional energy demands and issues with electricity and natural gas supplies over several days. Residential space heating drove the increases in demand, with over 60% of Texas homes using electric heat pumps and 35% using natural gas furnaces. Supply issues were caused by freezing equipment and supply lines, impacting both natural gas supplies and most forms of electricity generation. [1] Natural gas supplies were especially important because natural gas also supplied about 50% of the electricity generating capacity in ERCOT, the primary grid operator in Texas. [2] Due to the supply shortages, wholesale electricity prices were forced to the ERCOT maximum of $\$9,000$ /MWh for over three days (recent range $\$20$–40/MWh), [3] and natural gas prices for physical delivery exceeded $\$400$ /MMBtu in some areas (recent range $\$3$–4/MMBtu). [4]

03 NATURAL GAS↗

Performance and Cost Potential for Exemplar Direct Supercritical Carbon Dioxide Natural Gas Plants

This report presents the techno-economic analysis (TEA) optimization results of natural gas-fired utility-scale power plants based on the direct supercritical carbon dioxide (sCO 2 ) power cycle. To identify optimum plant configuration, the study also considered three different cases (Case A, Case B, Case C) with varying levels of thermal integration with the plant air separation unit (ASU). A fourth case (Case D), which is based on a patent from 8 Rivers, was also considered and includes thermal integration with the ASU as well as compressed recycle carbon dioxide (CO 2 ) gas. The four direct sCO 2 power plants offered similar or slightly higher plant efficiencies than the reference NGCC plants based on an F-class gas turbine with carbon capture and storage (CCS). LCOE of the direct sCO 2 plants is 13.5–17.2 percent higher than the reference NGCC plants with CCS due to higher capital costs associated with the ASU and sCO 2 power block. Recuperators make up over 50 percent of the power cycle costs. Consequently, any research and development (R&D) efforts to reduce the recuperator capital costs will be beneficial for the technology commercialization. The study also investigated the impact of co-firing landfill gas (LFG) and natural gas on plant efficiency, LCOE, and CO 2 emissions. Increasing the LFG co-firing from 0 percent to 50 percent (mass basis), decreased the plant efficiency by 0.3 percentage points and increased the LCOE by 3 percent. Due to high inherent CO 2 capture rates, direct sCO 2 plants have strong potential to achieve net-zero CO 2 emissions with LFG and natural gas co-firing.

03 NATURAL GAS↗

Field Testing of Self-Healing Metallic Coatings for Internal Corrosion Protection of Natural Gas Pipelines

Internal corrosion occurs in natural gas pipelines primarily due to the presence of water, carbon dioxide, and hydrogen sulfide. Internal corrosion can eventually result in leakage, cracks, and rupture of the pipeline. The objective of this work is to mitigate internal corrosion in steel pipelines transporting natural gas using cold spray coatings. The corrosion behavior of carbon steel coated with self-healing zinc chromium (ZnCr) and zinc niobium (ZnNb) cold spray coatings was investigated in a natural gas environment. For comparison purposes, hot-dip galvanized steel (HDGS) was tested under the same conditions as cold spray coatings. The field test was performed at the NW Natural gas storage facility in Mist, Oregon. The field test was conducted in a 6-inch diameter pipe transporting wet natural gas out of an underground storage well at 500 psi and 4.4 °C. The coupons were tested for 15 and 32 days under stagnant and flow conditions, respectively. Weight loss method was used to measure the corrosion rate of metallic coatings. Post-corrosion surface characterization was performed on the specimen using a scanning electron microscopy (SEM) equipped with energy dispersive X-ray spectroscopy (EDS). Crystalline phases were determined by X-ray diffraction (XRD). The field-test results confirmed that the metallic coatings provided corrosion protection of carbon steel exposed to wet natural gas under stagnant and flow conditions. The formation of the ZnCO 3 layer on top of ZnNb and ZnCr coatings led to passivation of the coatings which helps to reduce the self-corrosion. These layers form a barrier for diffusion of corrosive species to the surface.

03 NATURAL GAS↗

Refine your search to explore more results.