Xenon-Doped Liquid Argon TPCs as a Neutrinoless Double Beta Decay Platform

Next-generation large liquid argon time-projection chambers offer an unprecedented amount of active detector mass in a deep location. Modifications to the detector design could enable neutrinoless double beta decay searches, with the possibility of reaching the normal ordering region. These modifications include adding external neutron moderation, filling the detector with argon depleted in Ar42, doping with xenon, and a method to achieve percent-level energy resolution at the MeV scale. One way to achieve this desired level of energy resolution is to introduce a photosensitive dopant into the argon, converting the isotropic scintillation photons into a directional ionization signal. This would enhance the achievable energy resolution in large LArTPCs, and would lead to sizeable improvements to many facets of the broad physics program such a detector could offer.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neutron Yield of Thermo Scientific P385 D-T Neutron Generator vs . Current and Voltage

The Thermo Scientific P385 Neutron Generator is a compact neutron source, producing 14 MeV neutrons through the deuterium-tritium (DT) fusion reaction. It is important to measure and understand the dependence of the neutron production rate on the accelerator current and voltage. In this study we evaluated neutron production with an absolutely calibrated liquid scintillator neutron spectrometer (BTI N-Probe), an absolutely calibrated He-3 detector surrounded by HDPE shells (Detec Nested Neutron Spectrometer, NNS), and two uncalibrated ZnS fast neutron scintillators (EJ-410), for both A3082 and A3083 sealed tubes. Here we also modeled the neutron yield using the TRIM code, which calculates the trajectory and the energy loss of deuterons and tritons within the target. Experimental results showed an essentially linear dependence on beam current, as expected. A 3.59 ±0.08 power law dependence on the operating voltage was measured, in effective agreement with the modeled value of 3.5. A series of absolute NNS and N-Probe measurements, matched against MCNP calculations, showed that the A3083 and A3082 tubes provide a maximum neutron yield of 8.2 × 10 8 n/s and 4.7 × 10 8 n/s respectively, with estimated uncertainty of ±10%.We showed, through modeling, that tritium decay is not a significant consideration for tubes, such as these, with lifetimes of less than 10 years.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Feasibility study to use neutron capture for an ultralow energy nuclear-recoil calibration in liquid xenon

The feasibility of an ultra-low energy nuclear-recoil measurement in liquid xenon using neutron capture is investigated for a small (sub-kilogram) liquid xenon detector that is optimized for a high scintillation gain, and a pulsed neutron source. Further, the measurement uses the recoil energies imparted to xenon nuclei during the de-excitation process following neutron capture, where promptly emitted γ cascades can provide the nuclei with up to 0.3 keV nr of recoil energy due to conservation of momentum. A successful calibration of scintillation photon and ionization electron yields below this energy will contribute to a greater sensitivity for liquid xenon experiments in searches for light WIMPs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High-accuracy {sup 233}U(n,f) cross-section measurement at the white-neutron source n{sub T}OF from near-thermal to 1 MeV neutron energy

The {sup 233}U(n,f) cross section has been measured at the white neutron source n{sub T}OF in a wide energy range with a dedicated fission ionization chamber. We report here the results from {approx}30 meV to 1 MeV neutron energy. The {sup 233}U(n,f) cross section has been determined relative to a reference sample of {sup 235}U(n,f) measured simultaneously with the same detector. The very high instantaneous neutron flux and the intrinsically low background of the n{sub T}OF installation result in an accuracy around 3% in the whole energy range, while the energy resolution of the neutron beam allows for an accurate description of the fission cross section by means of R-matrix analysis over a wide energy range. The results are, in general, in good agreement with the most recent high-accuracy measurement of this fission cross section, over the more limited range of the previous measurements, and indicated that even the latest evaluations underestimate the cross section in the epithermal region. The present high-quality data provide the basis for a more precise evaluation of the {sup 233}U fission cross section and for improving the reliability of databases needed for the design of new energy systems based on the Th/U cycle.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron heating assessment in Minerve reactor by using alanine/ESR dosimetry

In the framework of the ICERR (International Center based on Research Reactors) project, the effect of neutron/gamma irradiation on material and dosimeters has been studied. In this work, we explore the alanine dose-response in the core of the MINERVE research reactor at the CEA Cadarache and we investigate the neutron heating effects in order to evaluate alanine neutron sensitivity. The measured dose of the alanine detector in the mixed gamma-neutron field was estimated by electron spin resonance spectrometry (ESR) with reference to an absorbed dose in water from a 60 Co gamma-ray beam. The experimental sources of uncertainties were reduced by using the optimum conditions of charged-particle equilibrium (CPE), obtained by introducing alanine dosimeters into the aluminum pillbox. Cavity correction factors and dose components were evaluated by the Monte Carlo code MCNP. The calculation showed an underestimated neutron dose with a (C/E) value of about 0.993 +/- 10.83%(k = 1). Results indicate that the fast neutron dose, mainly due to elastic neutron scattering on hydrogen nuclei, represents about 70% of the total dose, while the gamma dose was found to be around 45% of the neutron dose. Additionally, the neutron relative efficiency (REn) to 60 Co gamma-radiation was estimated to be 0.544 +/- 8%(k = 1).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Fast neutron leakage spectra of the EUCLID experiment

Special nuclear material in sub-critical and critical configurations measured in integral experiments are important for validation and adjustment of nuclear data. Many different evaluations of nuclear data exist, and these different evaluations can provide different values for individual cross sections that vary due to the uncertainties in differential experiments or lack of such data. For integral experiments, differences in these individual cross sections can have compensating errors, which lead to the same answer. One example of this is the Jezebel critical assembly, where k eff of the system is correctly computed by both ENDF/B-VIII.0 and JEFF-3.3, despite having substantially different underlying evaluated values for specific reactions (such as elastic and inelastic cross sections). To reduce compensating errors in nuclear data, the Experiments Underpinned by Computational Learning for Improvements in Nuclear Data (EUCLID) project has utilized machine learning to design a set of sub-critical and critical experiments. These experiments include slab- and cube-like configurations of 239 Pu in the form of the ZPPR plates. Six different responses were measured on a total of thirteen different configurations. One of these responses, the neutron leakage spectrum, was measured using an EJ301D detector. Finally, the results of the neutron leakage spectra show good agreement (within 1–2 σ ) with the expected spectrum from simulations and will be used in the subsequent nuclear data adjustment done by the EUCLID team.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NEUTRON MEASUREMENTS AT HANFORD’S PLUTONIUM FINISHING PLANT

The Pacific Northwest National Laboratory (PNNL) conducted neutron measurements at Hanford’s Plutonium Finishing Plant (PFP). The measurements were performed to evaluate the performance of the Hanford Standard Dosimeter (HSD) and the 8816 TLD component of the Hanford Combination Neutron Dosimeter (HCND) in the neutron fields responsible for worker neutron exposures. For this study, TEPC detectors and multisphere spectrometers were used to measure neutron dose equivalent rate, and multispheres were used to measure average neutron energy. Water-filled phantoms holding Hanford dosimeters were positioned at each measurement location. The phantoms were positioned in the same location where a multisphere measurement was taken and TEPCs were also positioned there. Plant survey meters were also used to measure neutron dose rates at all locations. Three measurement locations were chose near the HC-9B glovebox in room 228A of Building 234-5. The multisphere spectrometers measured average neutron energies in the range of 337 to 555 keV at these locations. Personal dose equivalent, Hp(10)n, as measured by the multisphere and TEPC, ranged from 2.7 to 9.7 mrem/h in the three locations. Effective dose assuming a rotational geometry (EROT) was substantially lower than Hp(10), ranging from 1.3 to 3.6 mrem/h. These values were lower than the reported values from dosimeters exposed on a rotating phantom. Effective dose assuming an AP geometry (EAP) was also substantially lower than Hp(10), ranging from 2.3 to 6.5 mrem/h. These values were lower than the reported values from the dosimeters on slab phantoms. Since the effective dose values were lower than reported values from dosimeters, the dosimeters were shown to be conservative estimates of the protection quantities.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neutrinos from SN 1987A and cooling of the nascent neutron star

The implications of the detection of neutrinos from SN 1987A for the cooling of the nascent neutron star are considered. The nu-bar(e) number N, the apparent temperature, the cooling time scale measured by the Kamioka and IMB detectors, and the inferred neutron star apparent radius and binding energy are all found to provide striking verification of current supernova theory.

Lamb, D. Q.↗

Monte Carlo simulation of the Neutrino-4 experiment

Monte Carlo simulation of the two-section reactor antineutrino detector of the Neutrino-4 experiment is carried out. The scintillation-type detector is based on the inverse beta-decay reaction. The antineutrino is recorded by two successive signals from the positron and the neutron. The simulation of the detector sections and the active shielding is performed. As a result of the simulation, the distributions of photomultiplier signals from the positron and the neutron are obtained. The efficiency of the detector depending on the signal recording thresholds is calculated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Processing of the Signals From Plasma Focus Discharge

Recent experiments of D-D reactions at the PF-1000 device in IPPLM Warsaw made possible to determine more exactly the time and energy distribution of produced neutrons due to ten scintillation detectors placed at distances between 7 and 85 m from the neutron source in both axial directions. In this article the de-noising of neutron signal via wavelet transformation is described. The signals were filtered with using the discrete wavelet transformation. The Mallat multiresolution algorithm was used, which divides the signal using decomposition coefficients and a hard. This method was used for filtration of the neutron signals acquired from D-D fusion reaction at the device PF 1000 in IPPLM Warsaw. We present comparison of detected and reconstructed signals and a temporal evolution of neutron energy distribution for shot No. 6573.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Prompt radiation detectors to monitor target conditions

Lessons learned by basic scientists in the study of experimental nuclear physics can often go unnoticed by cyclotron operator's intent on meeting a demanding schedule of tracer production. Prompt neutrons and gammas are the signature that the desired reaction is occurring, providing a robust measure of the expected yield.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Stochastic Template Bank for Gravitational Wave Searches for Precessing Neutron Star-Black Hole Coalescence Events

Gravitational wave searches to date have largely focused on non-precessing systems. Including precession effects greatly increases the number of templates to be searched over. This leads to a corresponding increase in the computational cost and can increase the false alarm rate of a realistic search. On the other hand, there might be astrophysical systems that are entirely missed by non-precessing searches. In this paper we consider the problem of constructing a template bank using stochastic methods for neutron star-black hole binaries allowing for precession, but with the restrictions that the total angular momentum of the binary is pointing toward the detector and that the neutron star spin is negligible relative to that of the black hole. We quantify the number of templates required for the search, and we explicitly construct the template bank. We show that despite the large number of templates, stochastic methods can be adapted to solve the problem. We quantify the parameter space region over which the non-precessing search might miss signals.

gravitational wave↗

Detection of thermal neutrons with a CMOS pixel sensor for a future dosemeter

The RaMsEs group (Radioprotection et Mesures Environnementales) is developing a new compact device for operational neutron dosimetry. The electronic part of the detector is made of an integrated active pixel sensor, originally designed for tracking in particle physics. This device has useful features for neutrons, such as high detection efficiency for charged particles, good radiation resistance, high readout speed, low power consumption and high rejection of photon background. A good response of the device to fast neutrons has already been demonstrated [1]. In order to test the sensibility of the detector to thermal neutrons, experiments have been carried out with a 512 x 512 pixel CMOS sensor on a californium source moderated with heavy water (Cf.D{sub 2}O) on the Van Gogh irradiator at the LMDN, IRSN, Cadarache (France)). A thin boron converter is used to benefit from the significant cross section of the {sup 10}B (n,{alpha}) {sup 7}Li reaction. Results show a high detection efficiency (around 10{sup -3}) of the device to thermal neutrons. Our measurements are in good agreement with GEANT4 Monte Carlo simulations. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Active Activation Diagnostics for High Energy X-ray and Neutron Measurements

Nuclear activation is a vital tool for diagnosing the properties of high-energy particles and photons. We investigate several potential reactions and suitable activation materials that could be used to simultaneously measure both neutrons and high-energy bremsstrahlung x-rays using one detector. Such a diagnostic would be valuable and practical for several facilities capable of creating such high-energy neutrons and x-rays. Laser-generated sources, such as NIF(-ARC) or Omega(-EP), have been shown to be capable of creating high-energy x-rays via high-intensity laser interactions and neutrons via DT fusion reactions. Furthermore, current laser technology is driving the demand for higher repetition rate diagnostics, hence we further constrain reaction/activation selections to accommodate high-repletion rate experiments. Our investigation will concentrate on identifying potential short half-life activation materials associated with high-energy x-ray reactions that could be incorporated into the existing realtime neutron activation detectors (RTNADs), an array of 48 activation detectors positioned around the NIF target chamber used to measure the DT neutron yield isotropy. We have identified two materials, gold and neodymium, that appear to be the best candidates to complement the RTNADs, by adding a new high-energy x-ray measurement capability.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

{gamma}-ray measurements and neutron sensitivity in a fusion environment

A system based on a LaBr{sub 3}(Ce) scintillator and digital data acquisition is discussed in view of {gamma}-ray spectroscopy measurements on a fusion burning plasma. High energy resolution and high rate capability of the system are demonstrated in laboratory tests and in dedicated experiments at nuclear accelerators. Preliminary results on sensitivity of the detector to 14 MeV neutrons are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗