Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Motor Controller”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

System and method for continuous solids slurry depressurization

A continuous slag processing system includes a rotating parallel disc pump, coupled to a motor and a brake. The rotating parallel disc pump includes opposing discs coupled to a shaft, an outlet configured to continuously receive a fluid at a first pressure, and an inlet configured to continuously discharge the fluid at a second pressure less than the first pressure. The rotating parallel disc pump is configurable in a reverse-acting pump mode and a letdown turbine mode. The motor is configured to drive the opposing discs about the shaft and against a flow of the fluid to control a difference between the first pressure and the second pressure in the reverse-acting pump mode. The brake is configured to resist rotation of the opposing discs about the shaft to control the difference between the first pressure and the second pressure in the letdown turbine mode.

36 MATERIALS SCIENCE↗

Collaborative Robots vs. Master/Slaves - 19522

This paper will discuss the feasibility, application, and economy of applying collaborative robots (co-bots) in lieu of traditional through-the-wall tele-operated manipulator systems, traditionally used within hazardous (radioactive) environments. Both fixed facility and mobile applications will be discussed. Both single- and dual-armed co-bot systems will be employed. The six-axis, plus gripper, single-armed co-bots will provide for machine vision enhanced pick-n-place applications within shielded rooms and also include force-reflecting (haptic) teleoperations controls for non-routine materials-handling operations. The dual-armed system will be mounted to a motorized stand with motorized adjustment both vertically and rotationally (around its base). To complement these co-bots, both two-dimensional and three-dimensional vision technologies will be implemented. The vision technologies, in these applications, are used in lieu of traditional radiation shielding windows. two-dimensional video systems will provide for large area viewing, incorporating pan, tilt, and zoom capabilities. Three-dimensional video systems will be mounted to the dual-armed robot stand and provide viewing, including depth-of-perception, to the operator, performing material handling and other tasks, from an operator workstation located outside the hazardous environment. The unique workstation used with the dual-armed systems will also be described. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Two-Armed, Mobile, Sensate Research Robot

The Anthropomorphic Robotic Testbed (ART) is an experimental prototype of a partly anthropomorphic, humanoid-size, mobile robot. The basic ART design concept provides for a combination of two-armed coordination, tactility, stereoscopic vision, mobility with navigation and avoidance of obstacles, and natural-language communication, so that the ART could emulate humans in many activities. The ART could be developed into a variety of highly capable robotic assistants for general or specific applications. There is especially great potential for the development of ART-based robots as substitutes for live-in health-care aides for home-bound persons who are aged, infirm, or physically handicapped; these robots could greatly reduce the cost of home health care and extend the term of independent living. The ART is a fully autonomous and untethered system. It includes a mobile base on which is mounted an extensible torso topped by a head, shoulders, and two arms. All subsystems of the ART are powered by a rechargeable, removable battery pack. The mobile base is a differentially- driven, nonholonomic vehicle capable of a speed >1 m/s and can handle a payload >100 kg. The base can be controlled manually, in forward/backward and/or simultaneous rotational motion, by use of a joystick. Alternatively, the motion of the base can be controlled autonomously by an onboard navigational computer. By retraction or extension of the torso, the head height of the ART can be adjusted from 5 ft (1.5 m) to 6 1/2 ft (2 m), so that the arms can reach either the floor or high shelves, or some ceilings. The arms are symmetrical. Each arm (including the wrist) has a total of six rotary axes like those of the human shoulder, elbow, and wrist joints. The arms are actuated by electric motors in combination with brakes and gas-spring assists on the shoulder and elbow joints. The arms are operated under closed-loop digital control. A receptacle for an end effector is mounted on the tip of the wrist and contains a force-and-torque sensor that provides feedback for force (compliance) control of the arm. The end effector could be a tool or a robot hand, depending on the application.

Engelberger, J. F.↗

A widefield fluorescence microscope with a linear image sensor for image cytometry of biospecimens: Considerations for image quality optimization

Linear image sensors have been widely used in numerous research and industry applications to provide continuous imaging of moving objects. Here, we present a widefield fluorescence microscope with a linear image sensor used to image translating objects for image cytometry. First, a calibration curve was characterized for a custom microfluidic chamber over a span of volumetric pump rates. Image data were also acquired using 15 μm fluorescent polystyrene spheres on a slide with a motorized translation stage in order to match linear translation speed with line exposure periods to preserve the image aspect ratio. Aspect ratios were then calculated after imaging to ensure quality control of image data. Fluorescent beads were imaged in suspension flowing through the microfluidics chamber being pumped by a mechanical syringe pump at 16 μl min{sup −1} with a line exposure period of 150 μs. The line period was selected to acquire images of fluorescent beads with a 40 dB signal-to-background ratio. A motorized translation stage was then used to transport conventional glass slides of stained cellular biospecimens. Whole blood collected from healthy volunteers was stained with 0.02% (w/v) proflavine hemisulfate was imaged to highlight leukocyte morphology with a 1.56 mm × 1.28 mm field of view (1540 ms total acquisition time). Oral squamous cells were also collected from healthy volunteers and stained with 0.01% (w/v) proflavine hemisulfate to demonstrate quantifiable subcellular features and an average nuclear to cytoplasmic ratio of 0.03 (n = 75), with a resolution of 0.31 μm pixels{sup −1}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reliability Improvement by Fault-Tolerant Operation of NPC Inverter for Motor Driving

The high-reliability operation of three-level inverters is crucial to prevent equipment damage, process downtime, and economic losses. This article investigates a three-level neutral-point-clamped inverter under all possible combinations of open-circuit and short-circuit faults and proposes a new postfault operation method without adding extra hardware. This method provides comprehensive solution for operations after single and multiple-device failures, increasing the inverter reliability by 24%. This article classified postfault modulations and uncovered previously unknown fault scenarios that can be addressed using the proposed control method. A new postfault modulation based on space vector modulation with virtual vectors is proposed. The feasibility of the proposed control method is verified by simulation and an experiment for one fault scenario in a three-level neutral-point-clamped inverter with a 3.73 kW motor load. Furthermore, this article contributes to improving the reliability of three-level inverters.

42 ENGINEERING↗

Feasibility Study of an All-Electric 150 Passenger Aircraft

Among the potential future technologies for low-carbon transport aircraft, all-electric concepts stand out environmentally, yet their feasibility and cost-effectiveness at scale remain uncertain. This paper examines the conceptual design of an all-electric 150-passenger aircraft with a range of 840 NM based on assumed future battery cell-level specific energy of1620Wh/kg. The tube and wing design is propelled by open rotors driven by four electric motors per nacelle and utilizes advanced structural materials for weight reduction. Powertrain technology gaps are identified. The conceptual design shows that all-electric aviation could supplant about 30% of current fossil fuel use by transport aircraft and potentially more with air-traffic-control modifications.

electric aircraft↗

Radiotherapy for Patients With Metastases to the Spinal Column: A Review of 603 Patients at Shizuoka Cancer Center Hospital

Purpose: Long- and short-course radiotherapy have similar outcomes in the treatment of spinal metastases. Long-course radiotherapy is recommended for patients with good predicted survival to reduce the risk of in-field recurrence, whereas short-course radiotherapy is used for those with poor predicted survival. Therefore, prediction of prognosis and local control is required for selecting the optimal course of radiotherapy. Methods and Materials: The subjects were 603 patients with spinal metastases who received radiotherapy at the Shizuoka Cancer Center Hospital between September 2002 and February 2007. Factors associated with survival and local control were retrospectively investigated by multivariate analyses. Local recurrence was defined as regrowth within the irradiated field or exacerbation of symptoms such as pain and motor deficits. Results: Of the 603 patients, 555 (92%) were followed for 12 months or until death. The survival rates after 6, 12, and 24 months were 50%, 32%, and 19%, respectively, with a median survival of 6.2 months. The median survival periods after long- and short-course radiotherapy were 7.9 and 1.8 months, respectively. In multivariate analysis, primary tumor site, good performance status, absence of previous chemotherapy, absence of visceral metastasis, single bone metastasis, younger age, and nonhypercalcemia were associated with good survival. The local control rates after 6, 12, and 24 months were 91%, 79%, and 69%, respectively, and non-mass-type tumor, breast cancer, and absence of previous chemotherapy were predictors of good local control. Conclusions: Identification of factors associated with good local control and survival may allow selection of an optimal radiotherapy schedule for patients with spinal metastases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sensorimotor integration in human postural control

It is generally accepted that human bipedal upright stance is achieved by feedback mechanisms that generate an appropriate corrective torque based on body-sway motion detected primarily by visual, vestibular, and proprioceptive sensory systems. Because orientation information from the various senses is not always available (eyes closed) or accurate (compliant support surface), the postural control system must somehow adjust to maintain stance in a wide variety of environmental conditions. This is the sensorimotor integration problem that we investigated by evoking anterior-posterior (AP) body sway using pseudorandom rotation of the visual surround and/or support surface (amplitudes 0.5-8 degrees ) in both normal subjects and subjects with severe bilateral vestibular loss (VL). AP rotation of body center-of-mass (COM) was measured in response to six conditions offering different combinations of available sensory information. Stimulus-response data were analyzed using spectral analysis to compute transfer functions and coherence functions over a frequency range from 0.017 to 2.23 Hz. Stimulus-response data were quite linear for any given condition and amplitude. However, overall behavior in normal subjects was nonlinear because gain decreased and phase functions sometimes changed with increasing stimulus amplitude. "Sensory channel reweighting" could account for this nonlinear behavior with subjects showing increasing reliance on vestibular cues as stimulus amplitudes increased. VL subjects could not perform this reweighting, and their stimulus-response behavior remained quite linear. Transfer function curve fits based on a simple feedback control model provided estimates of postural stiffness, damping, and feedback time delay. There were only small changes in these parameters with increasing visual stimulus amplitude. However, stiffness increased as much as 60% with increasing support surface amplitude. To maintain postural stability and avoid resonant behavior, an increase in stiffness should be accompanied by a corresponding increase in damping. Increased damping was achieved primarily by decreasing the apparent time delay of feedback control rather than by changing the damping coefficient (i.e., corrective torque related to body-sway velocity). In normal subjects, stiffness and damping were highly correlated with body mass and moment of inertia, with stiffness always about 1/3 larger than necessary to resist the destabilizing torque due to gravity. The stiffness parameter in some VL subjects was larger compared with normal subjects, suggesting that they may use increased stiffness to help compensate for their loss. Overall results show that the simple act of standing quietly depends on a remarkably complex sensorimotor control system.

NASA Discipline Neuroscience↗

Design and use of a servo-controlled high pressure window bomb in spectroscopic studies of solid propellant combustion

The feasibility of using a high pressure window bomb as a laboratory scale model of actual motor conditions. The design and operation of a modified high pressure window bomb is discussed. An optical servocontrol mechanism has been designed to hold the burning surface of a propellant strand at a fixed position within the bomb chamber. This mechanism permits the recording of visible and infrared emission spectra from various propellants. Preliminary visible emission spectra of a nonmetalized and metalized propellant are compared with spectra recorded using the modified bomb.

Goetz, F.↗

Commutating Permanent-Magnet Motors At Low Speed

Circuit provides forced commutation during starting. Forced commutation circuit diverts current from inverter SCR's and turns SCR's off during commutation intervals. Silicon controlled rectifier in circuit unnecessary when switch S10 replaced by high-current, high-voltage transistor. At present, high-current, low-voltage device must suffice.

Dolland, C.↗

Head Tilt Posturography to Enhance Balance Control Assessment for Astronauts: A Case Study

For many years, we have used a standard clinical computerized dynamic posturography (CDP) protocol to assess recovery of integrated sensory-motor function in astronauts returning from space flight. The most reliable indications of postflight crew performance capabilities have been obtained from the sensory organization tests (SOTs) within the CDP protocol, particularly SOTs 5 (eyes closed, surface support sway referenced) and 6 (eyes open, surface support and visual surround sway referenced), which are sensitive to changes in availability and/or utilization of vestibular cues. We have observed, however, that some astronauts exhibiting visible signs of incomplete sensory-motor recovery are able to score within clinical norms on standard SOTs 5 and 6 trials, perhaps as a result of cognitive strategies driven by their naturally competitive natures. To improve the sensitivity of the CDP protocol for assessing recovery of integrated sensory-motor function and fitness to return to duties and/or activities of daily living, we have introduced pitch plane head tilt SOT trials to our protocol. In a preliminary study of 5 short duration (~11day missions) astronauts, we showed that they were unable to maintain balance on landing day when performing dynamic head tilt trials, despite scoring within the clinically normal range on the standard SOT trials. The present case report illustrates the advantages of including head tilt trials for assessing sensory-motor recovery in long duration crewmembers.

Hwang, E. Y.↗

Voice Controlled Wheelchair

Michael Condon, a quadraplegic from Pasadena, California, demonstrates the NASA-developed voice-controlled wheelchair and its manipulator, which can pick up packages, open doors, turn a TV knob, and perform a variety of other functions. A possible boon to paralyzed and other severely handicapped persons, the chair-manipulator system responds to 35 one-word voice commands, such as "go," "stop," "up," "down," "right," "left," "forward," "backward." The heart of the system is a voice-command analyzer which utilizes a minicomputer. Commands are taught I to the computer by the patient's repeating them a number of times; thereafter the analyzer recognizes commands only in the patient's particular speech pattern. The computer translates commands into electrical signals which activate appropriate motors and cause the desired motion of chair or manipulator. Based on teleoperator and robot technology for space-related programs, the voice-controlled system was developed by Jet Propulsion Laboratory under the joint sponsorship of NASA and the Veterans Administration. The wheelchair-manipulator has been tested at Rancho Los Amigos Hospital, Downey, California, and is being evaluated at the VA Prosthetics Center in New York City.

Source record↗

Submodule Capacitor Reduction for a 1 MVA SiC-Based Modular Multilevel Converter Motor Drive using High Frequency Common-Mode Voltage Injection

This paper describes a strategy to reduce the size of submodule capacitors of a 1 MVA, 0-1 kHz, 7-level modular multilevel converter (MMC) based medium voltage variable speed drive (MVVSD) using 1.7 kV SiC MOSFETs. Hardware designs of submodules to withstand high dv/dt and capacitor selection based on common mode voltage injection have been presented in literature. The issue with injection is the error in tracking of injected circulation current which results in fundamental frequency fluctuations in the submodule capacitor voltage. This paper presents a strategy for higher frequency sinusoidal common mode voltage based on more accurate tracking of the circulating current; realized through an improved control strategy combined with a higher switching frequency. Using the methods presented in this paper, a smaller submodule capacitance and reduced output current THD of the motor drive is achieved. A loss analysis model is proposed to evaluate the effect of the proposed strategy on the MMC efficiency. This helps balance the reduction in the capacitor against the increase in the losses as a result of increased switching frequency. Simulations and a down-scaled experimental setup are used to demonstrate this concept.

Potty, Karun↗

Design and fabrication of a long-life Stirling cycle cooler for space application. Phase 3: Prototype model

A second-generation, Stirling-cycle cryocooler (cryogenic refrigerator) for space applications, with a cooling capacity of 5 watts at 65 K, was recently completed. The refrigerator, called the Prototype Model, was designed with a goal of 5 year life with no degradation in cooling performance. The free displacer and free piston of the refrigerator are driven directly by moving-magnet linear motors with the moving elements supported by active magnetic bearings. The use of clearance seals and the absence of outgassing material in the working volume of the refrigerator enable long-life operation with no deterioration in performance. Fiber-optic sensors detect the radial position of the shafts and provide a control signal for the magnetic bearings. The frequency, phase, stroke, and offset of the compressor and expander are controlled by signals from precision linear position sensors (LVDTs). The vibration generated by the compressor and expander is cancelled by an active counter balance which also uses a moving-magnet linear motor and magnetic bearings. The driving signal for the counter balance is derived from the compressor and expander position sensors which have wide bandwidth for suppression of harmonic vibrations. The efficiency of the three active members, which operate in a resonant mode, is enhanced by a magnetic spring in the expander and by gas springs in the compressor and counterbalance. The cooling was achieved with a total motor input power of 139 watts. The magnetic-bearing stiffness was significantly increased from the first-generation cooler to accommodate shuttle launch vibrations.

Keung, C.↗

Engineering microbes to produce biofuels

The current biofuels landscape is chaotic. It is controlled by the rules imposed by economic forces and driven by the necessity of finding new sources of energy, particularly motor fuels. The need is bringing forth great creativity in uncovering new candidate fuel molecules that can be made via metabolic engineering. These next generation fuels include long-chain alcohols, terpenoid hydrocarbons, and diesel-length alkanes. Renewable fuels contain carbon derived from carbon dioxide. The carbon dioxide is derived directly by a photosynthetic fuel-producing organism(s) or via intermediary biomass polymers that were previously derived from carbon dioxide. To use the latter economically, biomass depolymerization processes must improve and this is a very active area of research. There are competitive approaches with some groups using enzyme based methods and others using chemical catalysts. With the former, feedstock and end-product toxicity loom as major problems. Advances chiefly rest on the ability to manipulate biological systems. Computational and modular construction approaches are key. For example, novel metabolic networks have been constructed to make long-chain alcohols and hydrocarbons that have superior fuel properties over ethanol. A particularly exciting approach is to implement a direct utilization of solar energy to make a usable fuel. A number of approaches use the components of current biological systems, but re-engineer them for more direct, efficient production of fuels.

Wackett, LP↗

Dynamics of incremental motion devices associated with planetary exploration spacecraft

Incremental motion devices provide accurate and rapid movement of spacecraft science platforms, antennas and related mechanisms. The paper considers the computerized simulation of a stepper motor/gear train/ science platform system that will be launched on the Mariner Jupiter Saturn 1977. It was determined that a smaller stepper motor could be used as the prime mover for the science platform, and it was concluded that the existing digital controller was unable to achieve the required pointing accuracy, and a new controller design was necessary.

Hughes, R. O.↗

Phase Detector for Power-Factor Controller

Positive feedback assures reliable switching. Three Phase Power Factor Controller includes three phase detectors, each produces rectangular waves of duration approximately equal to lag time between line voltage and motor current.

Nola, F. J.↗

Neural networks as a control methodology

While conventional computers must be programmed in a logical fashion by a person who thoroughly understands the task to be performed, the motivation behind neural networks is to develop machines which can train themselves to perform tasks, using available information about desired system behavior and learning from experience. There are three goals of this fellowship program: (1) to evaluate various neural net methods and generate computer software to implement those deemed most promising on a personal computer equipped with Matlab; (2) to evaluate methods currently in the professional literature for system control using neural nets to choose those most applicable to control of flexible structures; and (3) to apply the control strategies chosen in (2) to a computer simulation of a test article, the Control Structures Interaction Suitcase Demonstrator, which is a portable system consisting of a small flexible beam driven by a torque motor and mounted on springs tuned to the first flexible mode of the beam. Results of each are discussed.

Mccullough, Claire L.↗

Refine your search to explore more results.