Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNET SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Horn Location Sensors for LBNF

The Horn Location Sensor (HLS) system—named for the magnetic focusing horns it monitors, along with other critical beamline elements – is a high-precision alignment system developed for the Long-Baseline Neutrino Facility (LBNF) to support the Deep Underground Neutrino Experiment (DUNE). With minimal maintenance, the HLS can operate reliably in environments with high radiation, and it ensures that key components such as the protective baffle, focusing horns, and beam position monitors are aligned correctly – each essential for maintaining one of the world’s most intense muon-neutrino beams. A high-precision hydrostatic level sensor, a linear variable differential transformer, and INVAR rods are all used in the system to monitor vertical motion and tilt with sub-millimeter accuracy. A novel Sweep Tracker interferometer enhances calibration fidelity by correcting for non-linearities in laser wavelength and scan rate in real time. A critical part of DUNE’s precision alignment and flux prediction requirements, the HLS system initially supports beam power of up to 1.2 MW and can be upgraded to 2.4 MW.

Frequency scanning interferometry↗

Observation of dimension dependent magnetic ordering in bismuth ferrite particulate and fiber nanostructures

Nanoparticles and nanofibers of bismuth ferrite were fabricated by sol-gel and electrospinning methods respectively. The structural and morphological analysis was carried out by XRD and FESEM techniques respectively. The magnetic measurements were carried out by SQUID magnetometer. The BFO nanofibers showed an enhanced magnetic property compared to nanoparticles. The observed magnetic properties were found to be associated with their magnetic ordering in the system where the antiferromagnetic/ferromagnetic core/shell like nature and ‘canted’ spin structure ordering was found to be the magnetic origin in the particulate and fiber nanostructures respectively.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Explicit expressions of quantum mechanical rotation operators for spins 1 to 2

Quantum mechanical rotation operators are the subject of quantum mechanics, mathematics and pulsed magnetic resonance spectroscopies, namely NMR, EPR and ENDOR. They are also necessary for spin based quantum information systems. The rotation operators of spin 1/2 are well known and can be found in related textbooks. But rotation operators of other spins greater than 1/2 can be found numerically by evaluating the series expansions of exponential operator obtained from Schrödinger equation, or by evaluating Wigner-d formula or by evaluating recently established expressions in polynomial forms discussed in the text. In this work, explicit symbolic expressions of x, y and z components of rotation operators for spins 1 to 2 are worked out by evaluating series expansion of exponential operator for each element of operators and utilizing linear curve fitting process. The procedures gave out exact expressions of each element of the rotation operators. The operators of spins greater than 2 are under study and will be published in a separate paper.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Confined states in photonic-magnonic crystals with complex unit cell

We have investigated multifunctional periodic structures in which electromagnetic waves and spin waves can be confined in the same areas. Such simultaneous localization of both sorts of excitations can potentially enhance the interaction between electromagnetic waves and spin waves. The system we considered has a form of one dimensional photonic-magnonic crystal with two types of magnetic layers (thicker and thinner ones) separated by sections of the dielectric photonic crystals. We focused on the electromagnetic defect modes localized in the magnetic layers (areas where spin waves can be excited) and decaying in the sections of conventional (nonmagnetic) photonic crystals. We showed how the change of relative thickness of two types of the magnetic layers can influence on the spectrum of spin waves and electromagnetic defect modes, both localized in magnetic parts of the system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Three axis vector atomic magnetometer utilizing polarimetric technique

The three axis vector magnetic field measurement based on the interaction of a single elliptically polarized light beam with an atomic system is described. The magnetic field direction dependent atomic responses are extracted by the polarimetric detection in combination with laser frequency modulation and magnetic field modulation techniques. The magnetometer geometry offers additional critical requirements like compact size and large dynamic range for space application. Further, the three axis magnetic field is measured using only the reflected signal (one polarization component) from the polarimeter and thus can be easily expanded to make spatial array of detectors and/or high sensitivity field gradient measurement as required for biomedical application.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spatial dependence of the super-exchange interactions for transition-metal trimers in graphene

This study examines the magnetic interactions between spatially variable manganese and chromium trimers substituted into a graphene superlattice. Using density functional theory, we calculate the electronic band structure and magnetic populations for the determination of the electronic and magnetic properties of the system. To explore the super-exchange coupling between the transition-metal atoms, we establish the magnetic ground states through a comparison of multiple magnetic and spatial configurations. Through an analysis of the electronic and magnetic properties, we conclude that the presence of transition-metal atoms can induce a distinct magnetic moment in the surrounding carbon atoms as well as produce a Ruderman-Kittel-Kasuya-Yosida-like super-exchange coupling. It is hoped that these simulations can lead to the realization of spintronic applications in graphene through electronic control of the magnetic clusters.

36 MATERIALS SCIENCE↗

Zero-field spin resonance in graphene with proximity-induced spin-orbit coupling

In this work we investigate collective spin excitations in graphene with proximity-induced spin-orbit coupling (SOC) of the Rashba and valley-Zeeman types, as it is the case, e.g., for graphene on transition-metal-dichalcogenide substrates. It is shown that, even in the absence of an external magnetic field, such a system supports collective spin modes, which correspond to coupled oscillations of the uniform and valley-staggered magnetizations. These modes can be detected via both zero-field electron spin resonance (ESR) and zero-field electric-dipole spin resonance (EDSR), with EDSR response arising solely due to Rashba SOC. We analyze the effect of electron-electron interaction within the Fermi-liquid kinetic equation and show that the interaction splits both the ESR and EDSR peaks into two. The magnitude of splitting and the relative weights of the resonances can be used to extract the spin-orbit coupling constants and many-body interaction parameters that may not be accessible by other methods.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Magnetic Field Control of Charge Structures in the Magnetically Disordered Phase of the Multiferroic LuFe2O4

Using neutron diffraction, we have studied the magnetic-field effect on charge structures in the charge-ordered multiferroic material LuFe{sub 2}O{sub 4}. An external magnetic field is able to change the magnitude and correlation lengths of the charge valence order even before the magnetic order sets in. This affects the dielectric and ferroelectric properties of the material and induces a giant magnetoelectric effect. Our results suggest that the magnetoelectric coupling in LuFe{sub 2}O{sub 4} is likely due to magnetic-field effect on local spins, in clear contrast to the case in most other known multiferroic systems where the bulk magnetic order is important.

36 MATERIALS SCIENCE↗

TU-AB-BRA-10: Treatment of Gastric MALT Lymphoma Utilizing a Magnetic Resonance Image-Guided Radiation Therapy (MR-IGRT) System: Evaluation of Gating Feasibility

Purpose: To evaluate the feasibility of real-time, real-anatomy tracking and gating for gastric lymphoma patients treated with magnetic resonance image-guided radiation therapy (MR-IGRT) Methods: Over the last 2 years, 8 patients with gastric lymphoma were treated with 0.3-T, Co-60 MR-IGRT. Post-treatment analysis of real-time cine imaging in the sagittal plane during each patient’s treatment revealed significant motion of the stomach. While this motion was accounted for with generous PTV margins, the system’s capability for real-time, real-anatomy tracking could be used to reduce treatment margins by gating. However, analysis was needed for the feasibility of gating using only the single available sagittal imaging plane. While any plane may be chosen, if the stomach moves differently where it is not being observed, there may potentially be a mistreatment. To that end, imaging with healthy volunteers was done to ascertain stomach motion over 2–4 min by analyzing multiple parallel sagittal and coronal planes 0.75 cm apart. The stomach was contoured on every slice, and the mean displacement between pairs of contour centroids was used to determine the amount of overall motion. Results: The mean displacement of the centroid in the image plane was 4.3 ± 0.7 mm. The greatest observed motion was more medial with respect to the patient, and less motion laterally, which implies that gating on a plane located closer to MRI isocenter will provide the more conservative scenario as it will turn the radiation delivery off when the stomach is observed to move outside a predetermined boundary. Conclusion: The stomach was observed to move relatively uniformly throughout, with maximum extent of motion closer to where most MRI systems have the best spatial integrity (near isocenter). Analysis of possible PTV margins from the healthy volunteer study (coupled with previous patient data on interfraction volumetric stomach deformation) is pending.

60 APPLIED LIFE SCIENCES↗

Magnetocaloric effect in GdCo x Al 2-x system for (0.15 ≤ x ≤ 1) compositions

Structure and magnetic properties of the GdAl 2 -GdCo 2 system including magnetocaloric effect have been investigated for various compositions. The as-cast GdCo x Al 2-x alloys prepared by arc-melting crystallize in the dual-phase structure of cubic MgCu 2 -type and hexagonal MgZn 2 -type phases. All the as-cast dual-phase alloys exhibit only one magnetic phase transition near 77 K even though two ferrimagnetic phases coexist. The magnetic transition was broadened by the continuous transitions of the component phases, which resulted in enhancement of relative cooling power at the expense of the magnetic entropy changes.

36 MATERIALS SCIENCE↗

Conceptual Design of the Interaction Region Magnets for Future Electron-Ion Collider at Jefferson Lab

The Jefferson Lab Electron Ion Collider (JLEIC) is a proposed new machine for nuclear physics research. As proposed, it will deliver between 15 and 65 GeV center of mass energy collisions between electrons and nuclei. It uses the existing CEBAF accelerator as a full energy injector to deliver 3 to 10 GeV electrons into a new electron collider ring. An all new ion accelerator and collider complex will deliver up to 100 GeV protons, or 40 GeV/nucleon ions. The machine will have luminosity goals of above 1033 cm-2 sec-1 in the whole energy range with a maximum of a few 1034 cm-2 sec-1. The two collider rings use a unique figure-of eight layout to deliver a high degree of polarization in both beams. The machine will include room for two interaction regions with only one initially installed. The crossing angle in the primary interaction region will be 50 mrad. The whole detector region including forward detection covers about 80 meters of the JLEIC complex. This paper will describe the requirements and preliminary designs for both the ion and electron beam magnets in the most complex 32 m long interaction region (IR) around the interaction point (IP). The interaction region has over thirty-seven superconducting magnets operating at 4.5K; these include dipoles, quadrupoles, skew-quadrupoles, solenoids, horizontal and vertical correctors and higher order multipole magnets. The paper will also discuss the electromagnetic interaction between these magnets.

Wiseman, Mark (ORCID:0000000179110306)↗

Classical trajectory Monte Carlo code for simulating ion beam focusing or defocusing with magnetic elements modeled as current loops or current lines

A computational tool is described that can be used for designing magnetic focusing or defocusing systems. A fully three-dimensional classical trajectory Monte Carlo simulation has been developed. Ion trajectories are simulated in the presence of magnetic elements that can be modeled as any combination of current loops and current lines. Each current loop or line may be located anywhere in the system and oriented along any of the three coordinate axes. The configuration need not be axisymmetric. The solutions are obtained using normalized parameters, which can be used for easily scaling the results. Examples are provided of the utility of the code.

43 PARTICLE ACCELERATORS↗

The effect of magnetic field on the structure of Coulomb crystal in dusty plasma

A molecular dynamics code is developed to study the formation of dust crystal and phase transition of a three-dimensional dusty plasma system in the presence of magnetic field. Under the influence of the magnetic field, the interaction potential among the grains gets modified and becomes anisotropic. The pair correlation function has been calculated to characterize the structural properties of the dusty plasma for different values of magnetic field strength. The phase diagram in the GAMMA-kappa plane is plotted for the system for different values of magnetic field strength. This diagram shows the existence of three phases: solid (fcc-like), solid (bcc-like), and fluid phases. It is seen that as the value of the magnetic field gets higher, the triple point shifts toward the lower value of the screening constant but higher value of Coulomb coupling parameter.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Scanning tunnelling spectroscopy as a probe of multi-Q magnetic states of itinerant magnets

The combination of electronic correlations and Fermi surfaces with multiple nesting vectors can lead to the appearance of complex multi-Q magnetic ground states, hosting unusual states such as chiral density waves and quantum Hall insulators. Distinguishing single-Q and multi-Q magnetic phases is however a notoriously difficult experimental problem. Here we propose theoretically that the local density of states (LDOS) near a magnetic impurity, whose orientation may be controlled by an external magnetic field, can be used to map out the detailed magnetic configuration of an itinerant system and distinguish unambiguously between single-Q and multi-Q phases. We demonstrate this concept by computing and contrasting the LDOS near a magnetic impurity embedded in three different magnetic ground states relevant to iron-based superconductors—one single-Q and two double-Q phases. Our results open a promising avenue to investigate the complex magnetic configurations in itinerant systems via standard scanning tunnelling spectroscopy, without requiring spin-resolved capability.

36 MATERIALS SCIENCE↗

Site-mixing effect on the XMCD spectrum in double perovskite Bi 2 FeMnO 6

We investigate magnetization in double perovskite multiferroic Bi 2 FeMnO 6 (BFMO) thin film using density functional theory (DFT) simulations, and X-ray magnetic circular dichroism (XMCD) measurements. The exchange interaction between Fe and Mn sites gives rise to a ferrimagnetic ordering in BFMO. When grown without structural defects, distinct XMCD signal is expected from this system. The site resolved magnetization, thus, can be extracted using XMCD sum rules. Although our theoretical calculations are consistent with this expectation for the ideal BFMO system, experimental measurements find evidence of anomalous peak for the L 2 and L 3 edges of XMCD signals, and thus, the XMCD sum rules are no longer valid. We theoretically explain this phenomenon by considering both tetragonal (near interface), and monoclinic (bulk) phases of BFMO system, with Fe and Mn ions interchanged between their respective sites. Such site-mixing between magnetic cations are commonly found during the synthesis process. Our DFT calculations of XMCD for site interchanged Fe and Mn ions in the bulk phase (monoclinic) of BFMO are in good agreement with experimental XMCD signal and reproduce the anomalous peak features at L 2 /L 3 edges.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Misalignment Tolerant Magnetic Coupler Design and Implementation for Wireless Charging of Unmanned Aerial Vehicles (UAVs)

Wireless power transfer technology is getting more attention these days as a part of expanded battery charging infrastructure and network at a wide range of power levels. Charging Unmanned aerial vehicles (UAVs) is one wireless charging application, and charging their batteries can be challenging because they have short flight times and are frequently charged. For wireless charging of UAVs, the misalignment performance of the magnetic coupler pads is critical because landing on a charging pad at a perfectly aligned position is difficult and can be time-consuming. Different coil shapes and system structures have been proposed in the literature to overcome this challenge. A new design with a high misalignment tolerance is needed; therefore, to fill this gap, a wireless power transfer system has been designed for a 250 W UAV battery charging system with a new magnetic coupler design. A 3D model of the proposed design was created, and finite element simulations were performed. To prove the proposed design, the magnetic coupler prototypes were developed, and experimental results are presented herein. The misalignment tolerance of the proposed system was observed for various rotational positions of the secondary coil, from 0° to 360°. The results demonstrate that DC–DC efficiency varies between 80% and 85% within full 360° rotation of the receiver coil. This result enables the proposed system to address the misalignment problem for wireless charging of UAVs.

UAVs↗

Refine your search to explore more results.