Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Low”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Microscopic model versus systematic low-energy effective field theory for a doped quantum ferromagnet

We consider a microscopic model for a doped quantum ferromagnet as a test case for the systematic low-energy effective field theory for magnons and holes, which is constructed in complete analogy to the case of quantum antiferromagnets. In contrast to antiferromagnets, for which the effective field theory approach can be tested only numerically, in the ferromagnetic case, both the microscopic and the effective theory can be solved analytically. In this way, the low-energy parameters of the effective theory are determined exactly by matching to the underlying microscopic model. The low-energy behavior at half-filling as well as in the single- and two-hole sectors is described exactly by the systematic low-energy effective field theory. In particular, for weakly bound two-hole states the effective field theory even works beyond perturbation theory. This lends strong support to the quantitative success of the systematic low-energy effective field theory method not only in the ferromagnetic but also in the physically most interesting antiferromagnetic case.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Surprising loss of three-dimensionality in low-energy spin correlations on approaching superconductivity in Fe 1 + y Te 1 - x Se x

We report inelastic neutron scattering measurements of low-energy ( ℏ ω ≲ 10 meV) magnetic excitations in the “11” system Fe 1+y Te 1-x Se x . The spin correlations are two-dimensional (2D) in the superconducting samples at low temperature, but appear much more three-dimensional (3D) when the temperature rises well above T c ~ 15 K, with a clear increase of the (dynamic) spin correlation length perpendicular to the Fe planes. This behavior is extremely unusual; typically, the suppression of thermal fluctuations at low temperature would favor the enhancement of 3D correlations, or even ordering, and the reversion to 2D cannot be naturally explained when only the spin degree of freedom is considered. Our results suggest that the low temperature physics in the 11 system, in particular the evolution of low-energy spin excitations towards superconducting pairing, intrinsically involves changes in orbital correlations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Low-energy collective modes of deformed superfluid nuclei within the finite-amplitude method

The major challenge for nuclear theory is to describe and predict global properties and collective modes of atomic nuclei. Of particular interest is the response of the nucleus to a time-dependent external field that impacts the low-energy multipole and β -decay strength, as well as individual nuclear excitations. We propose a method to compute low-lying collective modes in deformed nuclei within the finite-amplitude method (FAM) based on the quasiparticle random-phase approximation (QRPA). By using the analytic property of the response function, we find the QRPA amplitudes by computing the residua of the FAM amplitudes by means of a contour integration around the QRPA poles in a complex frequency plane. We use superfluid nuclear density functional theory with Skyrme energy density functionals, the FAM-QRPA approach, and the conventional matrix formulation of the QRPA. We demonstrate that the complex-energy FAM-QRPA method reproduces low-lying collective states obtained within the conventional matrix formulation of the QRPA theory. Illustrative calculations are performed for the isoscalar monopole strength in deformed 24 Mg and for low-lying $K = 0$ quadrupole vibrational modes of deformed Yb and Er isotopes. The proposed FAM-QRPA approach, in addition to providing a quick estimate of various strength functions, allows one to efficiently calculate the individual QRPA amplitudes of the low-lying collective modes in spherical and deformed nuclei throughout the entire nuclear landscape, in particular shape-vibrational and pairing-vibrational modes and β -decay rates. It can also be employed in microscopic approaches to large-amplitude nuclear collective motion based on the adiabatic self-consistent collective coordinate method.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Energetic ion, atom, and molecule reactions and excitation in low-current H{sub 2} discharges: Spatial distributions of emissions

Spatial distributions of H{sub {alpha}}, H{sub {beta}}, and the near-uv continuum emission from the H{sub 2} a {sup 3}{sigma}{sub g}{sup +} state are measured and compared with a model for low-current electrical discharges in H{sub 2} at high E/N and low Nd, where E is the spatially uniform electric field, N is the gas density, and d is the electrode separation. Data are analyzed for 300 Td<E/N<45 kTd, d=0.04 m, and 2x10{sup 21}<N<2.6x10{sup 22} m{sup -3}. (1 Td=10{sup -21} V m{sup 2}) The excitation is produced by electrons and by hydrogen atoms and molecules with mean energies from 5 to 1500 eV. Electron-induced emission, dominant at low E/N and low pressures, is distinguished by its buildup toward the anode. Excitation of H{sub {alpha}} by fast H atoms dominates at high E/N and increases toward the cathode. The observed H{sub {alpha}} emission at low E/N is normalized to previous experiments to yield absolute experimental excitation coefficients for all E/N and Nd. Small adjustments of model parameters yield good agreement with H{sub {alpha}} data. Cross sections are derived for excitation of the H{sub 2} near-uv continuum by H atoms. Spatial and pressure dependencies of H{sub {alpha}} and H{sub 2} near-uv emissions agree well with a model in which reactions of H{sub 2}{sup +}, H{sub 3}{sup +}, and H{sup +} ions with H{sub 2} lead to fast H atoms and H{sub 2} molecules, which then excite H atoms or H{sub 2} molecules.

74 ATOMIC AND MOLECULAR PHYSICS↗

Avalanche statistics from data with low time resolution

Extracting avalanche distributions from experimental microplasticity data can be hampered by limited time resolution. We compute the effects of low time resolution on avalanche size distributions and give quantitative criteria for diagnosing and circumventing problems associated with low time resolution. We show that traditional analysis of data obtained at low acquisition rates can lead to avalanche size distributions with incorrect power-law exponents or no power-law scaling at all. Furthermore, we demonstrate that it can lead to apparent data collapses with incorrect power-law and cutoff exponents. We propose new methods to analyze low-resolution stress-time series that can recover the size distribution of the underlying avalanches even when the resolution is so low that naive analysis methods give incorrect results. We test these methods on both downsampled simulation data from a simple model and downsampled bulk metallic glass compression data and find that the methods recover the correct critical exponents.

97 MATHEMATICS AND COMPUTING↗

Low-Energy Supernovae Severely Constrain Radiative Particle Decays

The hot and dense core formed in the collapse of a massive star is a powerful source of hypothetical feebly interacting particles such as sterile neutrinos, dark photons, axionlike particles (ALPs), and others. Radiative decays such as a→2γ deposit this energy in the surrounding material if the mean free path is less than the radius of the progenitor star. For the first time, we use a supernova (SN) population with particularly low explosion energies as the most sensitive calorimeters to constrain this possibility. These SNe are observationally identified as low-luminosity events with low ejecta velocities and low masses of ejected 56 Ni. Their low energies limit the energy deposition from particle decays to less than about 0.1 B, where 1 B(bethe) = 10 51 erg. For 1–500 MeV-mass ALPs, this generic argument excludes ALP-photon couplings G aγγ in the 10 -10 -10 -8 GeV -1 range.

79 ASTRONOMY AND ASTROPHYSICS↗

Deformable elastic network refinement for low-resolution macromolecular crystallography

An overview of applications of the deformable elastic network (DEN) refinement method is presented together with recommendations for its optimal usage. Crystals of membrane proteins and protein complexes often diffract to low resolution owing to their intrinsic molecular flexibility, heterogeneity or the mosaic spread of micro-domains. At low resolution, the building and refinement of atomic models is a more challenging task. The deformable elastic network (DEN) refinement method developed previously has been instrumental in the determinion of several structures at low resolution. Here, DEN refinement is reviewed, recommendations for its optimal usage are provided and its limitations are discussed. Representative examples of the application of DEN refinement to challenging cases of refinement at low resolution are presented. These cases include soluble as well as membrane proteins determined at limiting resolutions ranging from 3 to 7 Å. Potential extensions of the DEN refinement technique and future perspectives for the interpretation of low-resolution crystal structures are also discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Low-temperature high-mobility amorphous IZO for silicon heterojunction solar cells

Parasitic absorption in the transparent conductive oxide (TCO) front electrode is one of the limitations of silicon heterojunction (SHJ) solar cells efficiency. To avoid such absorption while retaining high conductivity, TCOs with high electron mobility are preferred over those with high carrier density. Here, we demonstrate improved SHJ solar cell efficiencies by applying high-mobility amorphous indium zinc oxide (a-IZO) as the front TCO. We sputtered a-IZO at low substrate temperature and low power density and investigated the optical and electrical properties, as well as subband tail formation-quantified by the Urbach energy (E U )-as a function of the sputtering oxygen partial pressure. We obtain an E U as low as 128 meV for films with the highest Hall mobility of 60 cm 2 /Vs. When comparing the performance of a-IZO films with indium tin oxide (ITO) and hydrogenated indium oxide (IO:H), we find that IO:H (115 cm 2 /Vs) exhibits a similar E U of 130 meV, while ITO (25 cm 2 /Vs) presents a much larger E U of up to 270 meV. The high film quality, indicated by the low E U , the high mobility, and low free carrier absorption of the developed a-IZO electrodes, result in a significant current improvement, achieving conversion efficiencies over 21.5%, outperforming those with standard ITO.

14 SOLAR ENERGY↗

A Custom Low-Noise Silicon Photodiode Detector Designed for Use With X-Ray Capillary Optics

We present the first results of a custom low-noise silicon photodiode detector designed for use with X-ray capillary optics. This system is intended to perform as a smaller, lighter, and low-powered alternative to currently existing X-ray telescope technologies. The detector has an active area with a diameter of 100 μm, and its small size leads to a low capacitance of well under 1 pF and a leakage current of 1 pA or less at the depletion voltage. We tested the detector with both a discrete preamp and an ultralow-noise front-end application-specific integrated circuit (ASIC). The front-end ASIC, developed at Brookhaven National Laboratory, was designed for low-capacitance detectors but had not been previously tested with a detector. Here, we discuss the detector design, the experimental setup, and the resulting detector performance. Using radioactive laboratory sources, we measure a full-width at half-maximum (FWHM) of 211 ± 8 eV at 5.9 keV with the ASIC and are able to set the threshold as low as 0.6 keV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-level regulation of the chloroplast ATP synthase: the chloroplast NADPH thioredoxin reductase C (NTRC) is required for redox modulation specifically under low irradiance

The chloroplast ATP synthase is known to be regulated by redox modulation of a disulfide bridge on thec-subunit through the ferredoxin–thioredoxin regulatory system. We show that a second enzyme, therecently identified chloroplast NADPH thioredoxin reductase C (NTRC), plays a role specifically at low irradi-ance. Arabidopsis mutants lacking NTRC (ntrc) displayed a striking photosynthetic phenotype in which feed-back regulation of the light reactions was strongly activated at low light, but returned to wild-type levels asirradiance was increased. This effect was caused by an altered redox state of the c-subunit under low, butnot high, light. The low light-specific decrease in ATP synthase activity in ntrc resulted in a buildup of thethylakoid proton motive force with subsequent activation of non-photochemical quenching and downregu-lation of linear electron flow. We conclude that NTRC provides redox modulation at low light using the rela-tively oxidizing substrate NADPH, whereas the canonical ferredoxin–thioredoxin system can take over athigher light, when reduced ferredoxin can accumulate. Based on these results, we reassess previous modelsfor ATP synthase regulation and propose that NTRC is most likely regulated by light. We also find that ntrcis highly sensitive to rapidly changing light intensities that probably do not involve the chloroplast ATP syn-thase, implicating this system in multiple photosynthetic processes, particularly under fluctuating environ-mental conditions.

59 BASIC BIOLOGICAL SCIENCES↗

Low-temperature ({<=}200 Degree-Sign C) plasma enhanced atomic layer deposition of dense titanium nitride thin films

Titanium nitride (TiN) has been widely used in the semiconductor industry for its diffusion barrier and seed layer properties. However, it has seen limited adoption in other industries in which low temperature (<200 Degree-Sign C) deposition is a requirement. Examples of applications which require low temperature deposition are seed layers for magnetic materials in the data storage (DS) industry and seed and diffusion barrier layers for through-silicon-vias (TSV) in the MEMS industry. This paper describes a low temperature TiN process with appropriate electrical, chemical, and structural properties based on plasma enhanced atomic layer deposition method that is suitable for the DS and MEMS industries. It uses tetrakis-(dimethylamino)-titanium as an organometallic precursor and hydrogen (H{sub 2}) as co-reactant. This process was developed in a Veeco NEXUS Trade-Mark-Sign chemical vapor deposition tool. The tool uses a substrate rf-biased configuration with a grounded gas shower head. In this paper, the complimentary and self-limiting character of this process is demonstrated. The effects of key processing parameters including temperature, pulse time, and plasma power are investigated in terms of growth rate, stress, crystal morphology, chemical, electrical, and optical properties. Stoichiometric thin films with growth rates of 0.4-0.5 A/cycle were achieved. Low electrical resistivity (<300 {mu}{Omega} cm), high mass density (>4 g/cm{sup 3}), low stress (<250 MPa), and >85% step coverage for aspect ratio of 10:1 were realized. Wet chemical etch data show robust chemical stability of the film. The properties of the film have been optimized to satisfy industrial viability as a Ruthenium (Ru) preseed liner in potential data storage and TSV applications.

36 MATERIALS SCIENCE↗

Effect of UV curing time on physical and electrical properties and reliability of low dielectric constant materials

This study comprehensively investigates the effect of ultraviolet (UV) curing time on the physical, electrical, and reliability characteristics of porous low-k materials. Following UV irradiation for various periods, the depth profiles of the chemical composition in the low-k dielectrics were homogeneous. Initially, the UV curing process preferentially removed porogen-related CH{sub x} groups and then modified Si-CH{sub 3} and cage Si-O bonds to form network Si-O bonds. The lowest dielectric constant (k value) was thus obtained at a UV curing time of 300 s. Additionally, UV irradiation made porogen-based low-k materials hydrophobic and to an extent that increased with UV curing time. With a short curing time (<300 s), porogen was not completely removed and the residues degraded reliability performance. A long curing time (>300 s) was associated with improved mechanical strength, electrical performance, and reliability of the low-k materials, but none of these increased linearly with UV curing time. Therefore, UV curing is necessary, but the process time must be optimized for porous low-k materials on back-end of line integration in 45 nm or below technology nodes.

36 MATERIALS SCIENCE↗

Side-by-side evaluation of the outgassing rate and ultimate pressure achieved inside tubes made of low-carbon and stainless steel

The hydrogen outgassing rate of a vacuum chamber made of AISI 1020 low-carbon steel was found to be notably smaller than a similar chamber made of AISI 316L stainless steel following heat treatment at 150 °C. When the chambers were baked at 400 °C, the outgassing rate of the 1020 low-carbon steel chamber was approximately 2000 times smaller than that of the 316L stainless-steel chamber. After quantifying hydrogen outgassing rates, vacuum chambers made of 1020 low-carbon steel and 316L stainless steel were heated for a prescribed duration and then pumped with an ion pump and nonevaporable getter pump to reach “ultimate pressure.” The 1020 low-carbon steel chamber reached lower pressures than the 316L stainless-steel chamber. Monte Carlo simulation predictions using the measured hydrogen outgassing rates are in good agreement with the ultimate pressure measurements. Finally, our measurements indicate that low-carbon steel can provide pressures within the extreme high vacuum range (<7.5 × 10 -13 Torr) if care is taken to minimize the surface area contribution from stainless steel.

36 MATERIALS SCIENCE↗

Outgassing measurements of bare and magnetite-coated low-carbon steel vacuum chambers

The outgassing properties of bare and magnetite-coated AISI 1020 low-carbon steel vacuum chambers were evaluated to establish material selection criteria for extreme high vacuum applications, namely, to explore the possibility of using these materials to build next-generation spin-polarized photoelectron guns. Water outgassing measurements using the throughput method revealed that the magnetite-coated chamber exhibited five times lower outgassing at room temperature prior to baking, but this advantage disappears after 80 °C baking. Hydrogen outgassing measurements demonstrated significant differences after intensive heat treatment: the bare low-carbon steel vacuum chamber achieved a specific outgassing rate of 9.6 × 10 −16 Torr L s −1 cm −2 after 400 °C/50 h bake plus additional heat treatment at lower temperatures, 25 times lower than the magnetite-coated low-carbon steel chamber. Residual gas analysis showed >99% hydrogen composition after heat treatment for both materials, with carbon species below detection limits for bare low-carbon steel versus 0.8% for magnetite-coated surfaces. These measurements indicate that properly conditioned bare low-carbon steel can achieve the <10 −12 Torr pressures required for next-generation spin-polarized photogun applications. In conclusion, the paper includes various analysis techniques intended to explain observed behaviors: isotherm analysis of pump-down plots, Arrhenius analysis of hydrogen outgassing rate data, and residual gas composition tracking.

Adsorption isotherm↗

Cherenkov photon background for low-noise silicon detectors in space

Future space observatories dedicated to direct imaging and spectroscopy of extra-solar planets will require ultra-low-noise detectors that are sensitive over a broad range of wavelengths. Silicon charge-coupled devices (CCDs), such as EMCCDs, Skipper CCDs, and Multi-Amplifier Sensing CCDs, have demonstrated the ability to detect and measure single photons from ultra-violet to near-infrared wavelengths, making them candidate technologies for this application. In this context, we study a relatively unexplored source of low-energy background coming from Cherenkov radiation produced by energetic charged particles traversing a silicon detector. In the intense radiation environment of space, energetic cosmic rays produce high-energy tracks and more extended halos of low-energy Cherenkov photons, which are detectable with ultra-low-noise detectors. We present a model of this effect that is calibrated to laboratory data, and we use this model to characterize the residual background rate for ultra-low noise silicon detectors in space. We find that the rate of cosmic-ray-induced Cherenkov photon production is comparable to other detector and astrophysical backgrounds that have previously been considered.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of scatter rejection and low-contrast performance of scan equalization digital radiography (SEDR), slot-scan digital radiography, and full-field digital radiography systems for chest phantom imaging

Purpose: To investigate and compare the scatter rejection properties and low-contrast performance of the scan equalization digital radiography (SEDR) technique to the slot-scan and conventional full-field digital radiography techniques for chest imaging. Methods: A prototype SEDR system was designed and constructed with an a-Se flat-panel (FP) detector to improve image quality in heavily attenuating regions of an anthropomorphic chest phantom. Slot-scanning geometry was used to reject scattered radiation without attenuating primary x rays. The readout scheme of the FP was modified to erase accumulated scatter signals prior to image readout. A 24-segment beam width modulator was developed to regulate x-ray exposures regionally and compensate for the low x-ray flux in heavily attenuating regions. To measure the scatter-to-primary ratios (SPRs), a 2 mm thick lead plate with a 2-D array of aperture holes was used to measure the primary signals, which were then subtracted from those obtained without the lead plate to determine scatter components. A 2-D array of aluminum beads (3 mm in diameter) was used as the low-contrast objects to measure the contrast ratios (CRs) and contrast-to-noise ratios (CNRs) for evaluating the low-contrast performance in chest phantom images. A set of two images acquired with the same techniques were subtracted from each other to measure the noise levels. SPRs, CRs, and CNRs of the SEDR images were measured in four anatomical regions of chest phantom images and compared to those of slot-scan images and full-field images acquired with and without antiscatter grid. Results: The percentage reduction of SPR (percentage of SPRs reduced with scatter removal/rejection methods relative to that for nongrid full-field imaging) averaged over four anatomical regions was measured to be 80%, 83%, and 71% for SEDR, slot-scan, and full-field with grid, respectively. The average CR over four regions was found to improve over that for nongrid full-field imaging by 259%, 279%, and 145% for SEDR, slot-scan, and full-field with grid, respectively. The average CNR over four regions was found to improve over that for nongrid full-field imaging by 201% for SEDR as compared to 133% for the slot-scan technique and 14% for the antiscatter grid method. Conclusions: Both SEDR and slot-scan techniques outperformed the antiscatter grid method used in standard full-field radiography. For imaging with the same effective exposure, the SEDR technique offers no advantage over the slot-scan method in terms of SPRs and CRs. However, it improves CNRs significantly, especially in heavily attenuating regions. The improvement of low-contrast performance may help improve the detection of the lung nodules or other abnormalities and may offer SEDR the potential for dose reduction in chest radiography.

60 APPLIED LIFE SCIENCES↗

Radiochromic film calibration for low-energy seed brachytherapy dose measurement

Purpose: Radiochromic film dosimetry is typically performed for high energy photons and moderate doses characterizing external beam radiotherapy (XRT). The purpose of this study was to investigate the accuracy of previously established film calibration procedures used in XRT when applied to low-energy, seed-based brachytherapy at higher doses, and to determine necessary modifications to achieve similar accuracy in absolute dose measurements. Methods: Gafchromic EBT3 film was used to measure radiation doses upwards of 35 Gy from 75 kVp, 200 kVp, 6 MV, and (∼28 keV) I-125 photon sources. For the latter irradiations a custom phantom was built to hold a single I-125 seed. Film pieces were scanned with an Epson 10000XL flatbed scanner and the resulting 48-bit RGB TIFF images were analyzed using both FilmQA Pro software andMATLAB. Calibration curves relating dose and optical density via a rational functional form for all three color channels at each irradiation energy were determined with and without the inclusion of uncertainties in the measured optical densities and dose values. The accuracy of calibration curve variations obtained using piecewise fitting, a reduced film measurement area for I-125 irradiation, and a reduced number of dose levels was also investigated. The energy dependence of the film lot used was also analyzed by calculating normalized optical density values. Results: Slight differences were found in the resulting calibration curves for the various fitting methods used. The accuracy of the calibration curves was found to improve at low doses and worsen at high doses when including uncertainties in optical densities and doses, which may better represent the variability that could be seen in film optical density measurements. When exposing the films to doses > 8 Gy, two-segment piecewise fitting was found to be necessary to achieve similar accuracies in absolute dose measurements as when using smaller dose ranges. When reducing the film measurement area for the I-125 irradiations, the accuracy of the calibration curve was degraded due to the presence of localized film heterogeneities. No degradation in the calibration curves was found when reducing the number of calibration points down to only 4, but with piecewise fitting, 6 calibration points as well as a blank film are required. Variations due to photon energy in film optical density of up to 3% were found above doses of 2 Gy. Conclusions: A modified procedure for performing EBT3 film calibration was established for use with low-energy brachytherapy seeds and high dose exposures. The energy dependence between 6 MV and I-125 photons is significant such that film calibrations should be done with an appropriately low-energy source when performing low-energy brachytherapy dose measurements. Two-segment piecewise fitting with the inclusion of errors in measured optical density as well as dose was found to result in the most accurate calibration curves. Above doses of 1 Gy, absolute dose measurements can be made with an accuracy of 1.6% for 6 MV beams and 5.7% for I-125 seed exposures if using the I-125 source for calibration, or 2.3% if using the 75 kVp photon beam for calibration.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-389: Effect of Interfractional Shoulder Motion On Low Neck Nodal Targets for Patients Treated Using Volume Modulated Arc Therapy (VMAT)

Purpose: To quantify the dosimetric impact of interfractional shoulder motion on targets in the low neck for head and neck patients treated with volume modulated arc therapy (VMAT). Methods: Three patients with head and neck cancer were selected. All three required treatment to nodal regions in the low neck in addition to the primary tumor. The patients were immobilized during simulation and treatment with a custom thermoplastic mask covering the head and shoulders. One VMAT plan was created for each patient utilizing two full 360° arcs. A second plan was created consisting of two superior VMAT arcs matched to an inferior static AP supraclavicular field. A CT-on-rails alignment verification was performed weekly during each patient's treatment course. The weekly CT images were registered to the simulation CT and the target contours were deformed and applied to the weekly CT. The two VMAT plans were copied to the weekly CT datasets and recalculated to obtain the dose to the low neck contours. Results: The average observed shoulder position shift in any single dimension relative to simulation was 2.5 mm. The maximum shoulder shift observed in a single dimension was 25.7 mm. Low neck target mean doses, normalized to simulation and averaged across all weekly recalculations were 0.996, 0.991, and 1.033 (Full VMAT plan) and 0.986, 0.995, and 0.990 (Half-Beam VMAT plan) for the three patients, respectively. The maximum observed deviation in target mean dose for any individual weekly recalculation was 6.5%, occurring with the Full VMAT plan for Patient 3. Conclusion: Interfractional variation in dose to low neck nodal regions was quantified for three head and neck patients treated with VMAT. Mean dose was 3.3% higher than planned for one patient using a Full VMAT plan. A Half-Beam technique is likely a safer choice when treating the supraclavicular region with VMAT.

60 APPLIED LIFE SCIENCES↗

Refine your search to explore more results.