Analysis of turbulent liquid-metal heat transfer in channels with heat sources in the fluid power-law velocity profile
Heat transfer characteristics for turbulent flow of heat generating liquid metals between parallel plates with wall heat transfer
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Heat transfer characteristics for turbulent flow of heat generating liquid metals between parallel plates with wall heat transfer
Background: Extracellular vesicles released by prostate cancer present in seminal fluid, urine, and blood may represent a non-invasive means to identify and prioritize patients with intermediate risk and high risk of prostate cancer. We hypothesize that enumeration of circulating prostate microparticles (PMPs), a type of extracellular vesicle (EV), can identify patients with Gleason Score≥4+4 prostate cancer (PCa) in a manner independent of PSA. Patients and Methods: Plasmas from healthy volunteers, benign prostatic hyperplasia patients, and PCa patients with various Gleason score patterns were analyzed for PMPs. We used nanoscale flow cytometry to enumerate PMPs which were defined as submicron events (100-1000nm) immunoreactive to anti-PSMA mAb when compared to isotype control labeled samples. Levels of PMPs (counts/µL of plasma) were also compared to CellSearch CTC Subclasses in various PCa metastatic disease subtypes (treatment naïve, castration resistant prostate cancer) and in serially collected plasma sets from patients undergoing radical prostatectomy. Results: PMP levels in plasma as enumerated by nanoscale flow cytometry are effective in distinguishing PCa patients with Gleason Score≥8 disease, a highrisk prognostic factor, from patients with Gleason Score≤7 PCa, which carries an intermediate risk of PCa recurrence. PMP levels were independent of PSA and significantly decreased after surgical resection of the prostate, demonstrating its prognostic potential for clinical follow-up. CTC subclasses did not decrease after prostatectomy and were not effective in distinguishing localized PCa patients from metastatic PCa patients. Conclusions: PMP enumeration was able to identify patients with Gleason Score ≥8 PCa but not patients with Gleason Score 4+3 PCa, but offers greater confidence than CTC counts in identifying patients with metastatic prostate cancer. CTC Subclass analysis was also not effective for post-prostatectomy follow up and for distinguishing metastatic PCa and localized PCa patients. Nanoscale flow cytometry of PMPs presents an emerging biomarker platform for various stages of prostate cancer.
A numerical analysis is presented for the overall performance of heat pipes with single or multiple heat sources. The analysis includes the heat conduction in the wall and liquid-wick regions as well as the compressibility effect of the vapor inside the heat pipe. The two-dimensional elliptic governing equations in conjunction with the thermodynamic equilibrium relation and appropriate boundary conditions are solved numerically. The solutions are in agreement with existing experimental data for the vapor and wall temperatures at both low and high operating temperatures.
General equations are derived for the approximate solution of the flow of a heavy infinite depth about a submerged circular cylinder where the center of the cylinder is submerged 1.5 diameter or greater. Then by replacing the cylinder by a dipole of a certain strength an equation is derived for the wave resistance of a circular cylinder moving in a fluid of finite depth.
Numerical methods are used to study thermally/gravitationally induced convection during solidification. The primary object is aimed at understanding the flow field in the liquid metal pool due to convection. An Al-0.5Fe weight percent alloy is assumed to fill a small scale vertical rectangular enclosure model for this study. The Alternating Direction Implicit method and Successive Overrelaxation method are employed to solve these equations, which include the energy balance equation coupled with the mass and momentum equations. Both transient and steady state conditions under 1 g and low gravity (0.001 g) are investigated. The solutions for the two-dimensional isotherms and streamlines under 1 g conditions are graphically presented. The quantitative results show that the convection which occurs in the liquid metal pool is very small and is likely to have a negligible effect on the solute redistribution ahead of the solid-liquid interface.
The natural world provides many examples of multiphase transport and reaction processes that have been optimized by evolution. These phenomena take place at multiple length and time scales and typically include gas–liquid–solid interfaces and capillary phenomena in porous media. Many biological and living systems have evolved to optimize fluidic transport. However, living things are exceptionally complex and very difficult to replicate, and human-made microfluidic devices (which are typically planar and enclosed) are highly limited for multiphase process engineering. In this paper, we introduce the concept of cellular fluidics: a platform of unit-cell-based, three-dimensional structures—enabled by emerging 3D printing methods—for the deterministic control of multiphase flow, transport and reaction processes. We show that flow in these structures can be ‘programmed’ through architected design of cell type, size and relative density. We demonstrate gas–liquid transport processes such as transpiration and absorption, using evaporative cooling and CO 2 capture as examples. We design and demonstrate preferential liquid and gas transport pathways in three-dimensional cellular fluidic devices with capillary-driven and actively pumped liquid flow, and present examples of selective metallization of pre-programmed patterns. Our results show that the design and fabrication of architected cellular materials, coupled with analytical and numerical predictions of steady-state and dynamic behaviour of multiphase interfaces, provide deterministic control of fluidic transport in three dimensions. Cellular fluidics may transform the design space for spatial and temporal control of multiphase transport and reaction processes.
Nuclear waste at Savannah River Site (SRS) waste tanks consists of three different types of waste forms. They are the lighter salt solutions referred to as supernate, the precipitated salts as salt cake, and heavier fine solids as sludge. The sludge is settled on the tank floor. About half of the residual waste radioactivity is contained in the sludge, which is only about 8 percentage of the total waste volume. Mixing study to be evaluated here for the Salt Disposition Integration (SDI) project focuses on supernate preparations in waste tanks prior to transfer to the Salt Waste Processing Facility (SWPF) feed tank. The methods to mix and blend the contents of the SRS blend tanks were evalutaed to ensure that the contents are properly blended before they are transferred from the blend tank such as Tank 50H to the SWPF feed tank. The work consists of two principal objectives to investigate two different pumps. One objective is to identify a suitable pumping arrangement that will adequately blend/mix two miscible liquids to obtain a uniform composition in the tank with a minimum level of sludge solid particulate in suspension. The other is to estimate the elevation in the tank at which the transfer pump inlet should be located where the solid concentration of the entrained fluid remains below the acceptance criterion (0.09 wt% or 1200 mg/liter) during transfer operation to the SWPF. Tank 50H is a Waste Tank that will be used to prepare batches of salt feed for SWPF. The salt feed must be a homogeneous solution satisfying the acceptance criterion of the solids entrainment during transfer operation. The work described here consists of two modeling areas. They are the mixing modeling analysis during miscible liquid blending operation, and the flow pattern analysis during transfer operation of the blended liquid. The modeling results will provide quantitative design and operation information during the mixing/blending process and the transfer operation of the blended liquid in the Salt Disposition Integration (SDI) facility. The results will also help validate the anticipated performance of the pump vendor's design.
The development of contactless flow meters is an important issue for monitoring and controlling of processes in different application fields, like metallurgy, liquid metal casting, or cooling systems for nuclear reactors and transmutation machines. Shercliff described in his book “The Theory of Electromagnetic Flow Measurement, Cambridge University Press, 1962” a simple and robust device for contact-less measurements of liquid metal flow rates which is known as magnetic flywheel. The sensor consists of several permanent magnets attached on a rotatable soft iron plate. This arrangement will be placed closely to the liquid metal flow to be measured, so that the field of the permanent magnets penetrates into the fluid volume. The flywheel will be accelerated by a Lorentz force arising from the interaction between the magnetic field and the moving liquid. Steady rotation rates of the flywheel can be taken as a measure for the mean flow rate inside the fluid channel. The present paper provides a detailed theoretical description of the sensor in order to gain a better insight into the functional principle of the magnetic flywheel. Theoretical predictions are confirmed by corresponding laboratory experiments. For that purpose, a laboratory model of such a flow meter was built and tested on a GaInSn-loop under various test conditions.
The fuel bundles of both PWR and BWR reactors require spacers to maintain the integrity and spacing of the slender fuel rods. These spacers can provide benefits such as increased mixing and turbulence, which increases heat distribution, leading to better Departure from Nucleate Boiling (DNB) conditions in PWRs. They also enhance the critical power ratios by increasing the thickness of the liquid layer in BWRs. However, the spacers also cause a pressure drop which must be engineered into the performance and operation. The flow within a rod bundle involves a number of complicated factors, such as cross flow, (de)entrainment of liquid layer, bubble or droplet break up/join. This requires specialized 3 dimensional computational fluid dynamics for the complete flow, however, most of the newly developed models have been accomplished by industry, so they are proprietary and in addition require extensive programming and cost to implement. In the public domain, a number of 1 dimensional equations have been developed that could benefit in initial design and decision making, if the equations are valid in the new and different applications the models are used. In 2002, an OECD/NRC BFBT benchmark workshop determined the variables used in the development of models, to predict flow within nuclear fuel bundles, had not been updated with technological advances to replace general theory and characteristics. If those properties could be identified and modeled, they could be applied to a wider range of conditions. This study utilizes NUPEC BFBT tests' measured data, on an average spacer over a range of pressure and flows, which was determined to be the most detailed measured data available. The focus is to describe the mathematical models of spacer grids and validate them with experimental results. This study consists of compiling and comparing available and established single phase equations and models computations. While these models may not have the desired degree of accuracy for final decisions, they may be accurate enough for the initial phases of design. No conclusion on a universal equation that fits all boundary conditions accurately or detailed effect of properties was determined. However, by using the BFBT experimental data, boundary conditions where the spacer grid models can be useful were identified. (authors)
Computational investigation of the countercurrent flows in an additively manufactured (AM) column packed with triply periodic minimal surface (TPMS) is challenging. Multiphase flow simulations using the volume of fluid (VOF) method can explain the column’s hydrodynamic characteristics, including interfacial area, liquid holdup, pressure drop, flow regime, etc. The interfacial area is a key factor dictating the mass transfer via the absorption process, and thereby the overall efficiency of the column. The impacts of a solvent's physical properties, liquid and gas loads, and contact angle on the hydrodynamics are extensively explored. The solvents include traditional solvent (monoethanolamine [MEA]) used in industry as well as a water-lean solvent (EEMPA) as prospective solvents for carbon capture. As expected, interfacial area and liquid holdup increase with increasing liquid loads (q L ). The EEMPA exhibits higher values for the interfacial area and liquid holdup compared to those for the MEA. The dry and wet pressure drops per unit length in the column at different gas loads (F G ) are calculated and further compared with the empirical correlations for traditional packings. At low gas loads, i.e., in the preloading regime, the predicted values of the wet and dry pressure drops match well with the corresponding values calculated from available correlations. The gas load has a marginal impact on the interfacial area at its lower value, but the higher value of F G (>2.18 $\sqrt{Pa}$) causes flooding in the column. The effect of varying contact angles on the interfacial area and liquid holdup in the preloading regime is also studied. Both interfacial area and liquid holdup decrease with the increase in the value of the contact angle. Altogether, the effect of the contact angle on interfacial area is more pronounced than other parameters influencing the interfacial area.
During the course of this investigation, the following two topics were studied theoretically: (1) forced convection and sedimentation past a flat plate, and (2) the effect of rain on airfoil performance. The prototype of the first topic is that of air flowing past the wing section of an aircraft under heavy rain and high windshear. The long-range objective of this project was to identify the various factors determining the dynamics of the flow and then to develop a theoretical framework for modeling such systems. The second topic focused on the idea that the presence of the gas-liquid interface (being the air flow around the airfoil and the thin liquid film created by the rain) accelerates flow separation and thus induces performance losses.
Vortex amplifier for controlling secondary flow for thrust vector control of liquid rocket engine
The development of instrumentation for the support of research in two-phase flow in simulated microgravity conditions was performed. The funds were expended in the development of a technique for characterizing the motion and size distribution of small liquid droplets dispersed in a flowing gas. Phenomena like this occur in both microgravity and normal earth gravity situations inside of conduits that are carrying liquid-vapor mixtures at high flow rates. Some effort to develop a conductance probe for the measurement of liquid film thickness was also expended.
We developed an integrated Computational Fluid Dynamics (CFD) model to simulate the multi-physics coupled cooling process of mixed gas by cold water within a Direct Contact Cooler (DCC) equipped with a rotating packing bed (RPB). The model captures the interactions between fluid dynamics, heat transfer, mass transport, and phase transitions, while accounting for key operational variables such as RPB rotational speed and the mass flow rates of both liquid and gas. The CFD model has been validated using experimental data, specifically by comparing predicted outflow gas and liquid temperatures to measured results. Our findings demonstrate the significant effects of RPB rotational speed and mass flow rates on cooling performance, providing valuable insights for optimizing DCC efficiency in industrial applications.
The effects of nozzle design on dispersed, two-phase flows of the steel-argon system in a slab mold are studied using a water-air model with particle image velocimetry and ultrasound probe velocimetry techniques. Three nozzle designs were tested with the same bore size and different port geometries, including square (S), special bottom design with square ports (U), and circular (C). The meniscus velocities of the liquid increase two- or threefold in two-phase flows regarding one-phase flows using low flow rates of the gas phase. This effect is due to the dragging effects on bubbles by the liquid jets forming two-way coupled flows. Liquid velocities (primary phase) along the narrow face of the mold also are higher for two-phase flows. Flows using nozzle U are less dependent on the effects of the secondary phase (air). The smallest bubble sizes are obtained using nozzle U, which confirms that bubble breakup is dependent on the strain rates of the fluid and dissipation of kinetic energy in the nozzle bottom and port edges. Through dimensionless analysis, it was found that the bubble sizes are inversely proportional to the dissipation rate of the turbulent kinetic energy, ε{sup 0.4}. A simple expression involving ε, surface tension, and density of metal is derived to scale up bubble sizes in water to bubble sizes in steel with different degrees of deoxidation. The validity of water-air models to study steel-argon flows is discussed. Prior works related with experiments to model argon bubbling in steel slab molds under nonwetting conditions are critically reviewed.
Two-phase flows were investigated by using high velocity nitrogen gas streams to atomize small-diameter liquid jets. Tests were conducted primarily in the acceleration-wave regime for liquid jet atomization, where it was found that the loss of droplets due to vaporization had a marked effect on drop size measurements. In addition, four identically designed two-fluid atomizers were fabricated and tested for similarity of spray profiles. A scattered-light scanner was used to measure a characteristic drop diameter, which was correlated with nitrogen gas flowrate. The exponent of 1.33 for nitrogen gas flowrate is identical to that predicted by atomization theory for liquid jet breakup in the acceleration-wave regime. This is higher than the value of 1.2 which was previously obtained at a sampling distance of 4.4 cm downstream of the atomizer. The difference is attributed to the fact that drop-size measurements obtained at a 2.2 cm sampling distance are less effected by vaporization and dispersion of small droplets and therefore should give better agreement with atomization theory. Profiles of characteristic drop diameters were also obtained by making at least five line-of-sight measurements across the spray at several horizontal positions above and below the center line of the spray.
Two-phase flows were investigated by using high velocity nitrogen gas streams to atomize small-diameter liquid jets. Tests were conducted primarily in the acceleration-wave regime for liquid jet atomization, where it was found that the loss of droplets due to vaporization had a marked effect on drop-size measurements. In addition, four identically designed two-fluid atomizers were fabricated and tested for similarity of spray profiles. A scattered-light scanner was used to measure a characteristic drop diameter, which was correlated with nitrogen gas flowrate. The exponent of 1.33 for nitrogen gas flowrate is identical to that predicted by atomization theory for liquid jet breakup in the acceleration-wave regime. This is higher than the value of 1.2 which was previously obtained at a smapling distance of 4.4 cm downstream of the atomizer. The difference is attributed to the fact that drop-size measurements obtained at a 2.2 cm sampling distance are less affected by vaporization and dispersion of small droplets and therefore should give better agreement with atomization theory. Profiles of characteristic drop diameters were also obtained by making at least five line-of-sight measurements across the spray at several horizontal positions above and below the center line of the spray.
We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with one of the flat walls of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the microwave resonant frequency, which can be detected with a spectrum analyzer. We have performed a preliminary proof-of-principle test of flow sensing in high temperature liquid sodium in environment. The liquid sodium setup consists of a cylindrical vessel with a center feed line, where a transducer inserted through the top cap of the vessel measures velocity of the impinging liquid jet. For this test, we have developed a cylindrical resonator, which was machined from stainless steel 316 and electroplated with silver on the interior surfaces. Inner diameter of the cylindrical cavity is 22.2 mm, and the thin wall is approximately 200µm thick. The cavity was excited through a WR-42 waveguide through a subwavelength hole on the side of the wall of the cylinder in the TE 011 mode with resonant frequency f ≈ 17.8GHz. Sodium flow rate sensing study was performed in a liquid sodium vessel at 340°C temperature and ambient pressure. The flow rate was changed by varying sodium pump power, and a frequency shift of several hundred KHz was observed. From the measurements, we observed significant scatter in high temperature liquid sodium at low flow velocity values. Our hypothesis is that this is caused by temperature drift in the liquid, which results in thermal expansion of the cavity and a drift in the resonator frequency. In this report, we investigate temperature dependence of the resonant frequency through development of analytic models and preliminary analysis of experimental data. In addition, we develop a procedure for compensation for temperature drift during flow sensing.
Refine your search to explore more results.