Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Linearization error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Building America Case Study: Predicting Envelope Leakage in Attached Dwellings (Fact Sheet)

'The cost for blower testing is high, because it is labor intensive, and it may disrupt occupants in multiple units. This high cost and disruption deters program participants, and dissuades them from pursuing energy improvements that would trigger air leakage testing, such as improvements to the building envelope.' This statement found in a 2012 report by Heschong Mahone Group emphasizes the importance of reducing the cost and complexity of blower testing in multifamily buildings. Energy efficiency opportunities are being bypassed. The cost of single blower testing is on the order of $300. The cost for guarded blower door testing, the more appropriate test for assessing energy savings opportunities, could easily be six times that and that's only if you have the equipment and simultaneous access to multiple apartments. Thus, the proper test is simply not performed. The objective of the 2013 research project was to develop the model for predicting fully guarded test results (FGT), using unguarded test data and specific building features of apartment units. The model developed has a coefficient of determination R2 value of 0.53 with a root mean square error (RMSE) of 0.13. Both statistical metrics indicate that the model is relatively strong. When tested against data that was not included in the development of the model, prediction accuracy was within 19%, which is reasonable given that seasonal differences in blower door measurements can vary by as much as 25%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of Lobe Power Calculator and Indication System with Physics and Cycle Based Models

The Advanced Test Reactor (ATR) at INL measures reactor power through two methods, thermal and Nitrogen-16 (N-16) activity. Water power calculator (WPC) is a thermal power system that measures flow and temperature to determine the thermal quadrant powers. The N-16 system utilizes a beta chamber detector that outputs reactivity levels to calculate lobe power through an algorithm called lobe power calculation and indication system (LPCIS). The LPCIS utilizes the N-16 system and the WPC system to determine reactor core power levels. The WPC provides accurate calculations of quadrant and total reactor thermal power. With the use of WPC measurements, thermal-to-N-16 (T2N) power ratios are produced to determine if the two indication systems agree on core power. Relative magnitude equations are used to utilize N-16 coefficients and multipliers to improve the indications of the LPCIS. This is crucial for maintaining safety limits. Currently, the LPCIS system uses linear equations and matrices to calculate lobe power through multipliers and coefficients. Advancements in technology and system upgrades have assisted system engineers at INL with the objective to reach a more dynamic system. In return the system demonstrates an increase in the accuracy of power reading while maintaining safety margins. The new proposed coefficient and multiple method implements a cycle specific, and a physics-based model intended for changing coefficients during operation. This calibration experiment focuses on power splitting, outer shim and neck shim, as well as fuel burning into the RDAS weighting factors. Results show that the Physics learning method yields a smaller error margin inside of the desired power range for the data set 166-A. This proved true for both constrained and unconstrained testing. This is most likely due to the physics data fitting approach that resulted in favorable coefficients and multipliers for 166-A. Continuing to improve the physics-based model will help improve the power accuracy of the LPCIS system.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Evidence for B+ -> K*0bar K*+

We present measurements of the branching fraction and fraction of longitudinal polarization for the decay B{sup +} {yields} {bar K}*{sup 0} K*{sup +} with a sample of 467 {+-} 5 million B{bar B} pairs collected with the BABAR detector at the PEP-II asymmetric-energy e{sup +}e{sup -} collider at the SLAC National Accelerator Laboratory. We obtain the branching fraction {Beta}(B{sup +} {yields} {bar K}*{sup 0} K*{sup +}) = (1.2 {+-} 0.5 {+-} 0.1) x 10{sup ?6} with a significance of 3.7 standard deviations including systematic uncertainties. We measure the fraction of longitudinal polarization f{sub L} = 0.75{sub -0.26}{sup +0.16} {+-} 0.03. The first error quoted is statistical and the second is systematic.

43 PARTICLE ACCELERATORS↗

Quantum simulation of second-quantized Hamiltonians in compact encoding

We describe methods for simulating general second-quantized Hamiltonians using the compact encoding, in which qubit states encode only the occupied modes in physical occupation number basis states. These methods apply to second-quantized Hamiltonians composed of a constant number of interactions, i.e., linear combinations of ladder operator monomials of fixed form. Compact encoding leads to qubit requirements that are optimal up to logarithmic factors. Here, we show how to use sparse Hamiltonian simulation methods for second-quantized Hamiltonians in compact encoding, give explicit implementations for the required oracles, and analyze the methods. We also describe several example applications including the free boson and fermion theories, the φ 4 -theory, and the massive Yukawa model, all in both equal-time and light-front quantization. Our methods provide a general-purpose tool for simulating second-quantized Hamiltonians, with optimal or near-optimal scaling with error and model parameters.

97 MATHEMATICS AND COMPUTING↗

Performance of methods for SARS-CoV-2 variant detection and abundance estimation within mixed population samples

The accurate identification of SARS-CoV-2 (SC2) variants and estimation of their abundance in mixed population samples (e.g., air or wastewater) is imperative for successful surveillance of community level trends. Assessing the performance of SC2 variant composition estimators (VCEs) should improve our confidence in public health decision making. Here, we introduce a linear regression based VCE and compare its performance to four other VCEs: two re-purposed DNA sequence read classifiers (Kallisto and Kraken2), a maximum-likelihood based method (Lineage deComposition for Sars-Cov-2 pooled samples (LCS)), and a regression based method (Freyja). We simulated DNA sequence datasets of known variant composition from both Illumina and Oxford Nanopore Technologies (ONT) platforms and assessed the performance of each VCE. We also evaluated VCEs performance using publicly available empirical wastewater samples collected for SC2 surveillance efforts. Bioinformatic analyses were performed with a custom NextFlow workflow (C-WAP, CFSAN Wastewater Analysis Pipeline). Relative root mean squared error (RRMSE) was used as a measure of performance with respect to the known abundance and concordance correlation coefficient (CCC) was used to measure agreement between pairs of estimators. Based on our results from simulated data, Kallisto was the most accurate estimator as it had the lowest RRMSE, followed by Freyja. Kallisto and Freyja had the most similar predictions, reflected by the highest CCC metrics. We also found that accuracy was platform and amplicon panel dependent. For example, the accuracy of Freyja was significantly higher with Illumina data compared to ONT data; performance of Kallisto was best with ARTICv4. However, when analyzing empirical data there was poor agreement among methods and variations in the number of variants detected (e.g., Freyja ARTICv4 had a mean of 2.2 variants while Kallisto ARTICv4 had a mean of 10.1 variants). This work provides an understanding of the differences in performance of a number of VCEs and how accurate they are in capturing the relative abundance of SC2 variants within a mixed sample (e.g., wastewater). Such information should help officials gauge the confidence they can have in such data for informing public health decisions.

60 APPLIED LIFE SCIENCES↗

Projection-Based linear constrained estimation and fusion over long-haul links

We study estimation and fusion with linear dynamics in long-haul sensor networks, wherein a number of sensors are remotely deployed over a large geographical area for performing tasks such as target tracking, and a remote fusion center serves to combine the information provided by these sensors in order to improve the overall tracking accuracy. In reality, the motion of a dynamic target might be subject to certain constraints, for instance, those defined by a road network. We explore the accuracy performance of projection-based constrained estimation and fusion methods that is affected by information loss over the long-haul links. We use an example to compare the tracking errors under various implementations of centralized and distributed projection-based estimation and fusion methods and demonstrate the effectiveness of using projection-based methods in these settings.

Rao, Nageswara S↗

Evaluating Photocatalysts Using Gamma Radiation

A large amount of attention has been given to photocatalysts using UV radiation as the source of excitation; however, little work has been done to study photocatalysis using higher energy excitation sources, such as gamma or x-rays. During excitation, the photocatalyst absorbs light to produce electron-hole pairs (excitons). These excitons can react with absorbed species to yield reactive radical species that can degrade compounds or induce redox (oxidation-reduction) reactions. Common examples of semiconductor photocatalysts include: TiO{sub 2}, ZnO, Fe{sub 2}O{sub 3}, ZrO{sub 2}, and SnS. This project was conducted to investigate the photocatalytic oxidation of iron using gamma irradiation and several different semiconductor photocatalysts. Photometric Measurements: Photometric determination of Fe{sup II} and Fe{sup III} were made using a Cary 60 UV-Vis Spectrometer over a range of 800 - 200 nm at a scan rate of 60 nm/sec. Ferric (Fe{sup III}) ions have no detectable UV-vis spectrum, thus the absence of a peak in iron-based samples was taken as evidence of Fe{sup III} formation. Solution Preparation: Iron II (Fe{sup II}) standards were made by dissolving FeCl{sub 2}.6H{sub 2}O in deionized water using a sonicator. A solution of 1,10- phenanthroline was made by adding 40 mg of 1,10-phenanthroline to 20 mL of deionized water and sonicating for 60 minutes until a clear solution was obtained. Gamma Radiation Tests: Irradiated samples were exposed to Co-60 gamma radiation (1.17 MeV gamma) at a dose rate of ∼1 x 10{sup 5} Rad/hr Co-60. All samples were irradiated in glass scintillation vials. The presence of 30 mg of SnS reduces the amount of Fe{sup II} in solutions under gamma irradiation relative to samples with no SnS added. Fe{sup II} concentration decreases as irradiation time increases. This effect is enhanced when SnS is present. Fe{sup II} appears to decrease linearly with time. We found that the addition of SnS semiconductor, when combined with gamma radiation, oxidized more Fe{sup II} in the FeCl{sub 2} solution than gamma radiation alone. This suggests that SnS can be used as a photocatalyst using gamma radiation as the excitation source, although more detailed experiments are needed to confirm this belief. The next phase of this project would be to refine the preliminary results by determining exact quantities of SnS semiconductor and gamma radiation that induce sufficient redox. Repeated experiments with more samples could also give more data points for a chance at more representative and accurate data with error bars and standard deviations. Also, other semiconductors could possibly be tested to see how their effect on redox chemistry compares to that of SnS. The scope of this project could also be extended to include other metal or organic solutions to see if similar redox could be obtained.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Energy-Charge-conserving, Implicit, Electrostatic Particle-in-Cell Algorithm

This paper discusses a novel fully implicit formulation for a one-dimensional electrostatic particle-in-cell (PIC) plasma simulation approach. Unlike earlier implicit electrostatic PIC approaches (which are based on a linearized Vlasov-Poisson formulation), ours is based on a nonlinearly converged Vlasov-Ampere (VA) model. By iterating particles and fields to a tight nonlinear convergence tolerance, the approach features superior stability and accuracy properties, avoiding most of the accuracy pitfalls in earlier implicit PIC implementations. In particular, the formulation is stable against temporal (Courant-Friedrichs-Lewy) and spatial (aliasing) instabilities. It is charge- and energy-conserving to numerical round-off for arbitrary implicit time steps (unlike the earlier ''energy-conserving'' explicit PIC formulation, which only conserves energy in the limit of arbitrarily small time steps). While momentum is not exactly conserved, errors are kept small by an adaptive particle sub-stepping orbit integrator, which is instrumental to prevent particle tunneling (a deleterious effect for long-term accuracy). The VA model is orbit-averaged along particle orbits to enforce an energy conservation theorem with particle sub-stepping. As a result, very large time steps, constrained only by the dynamical time scale of interest, are possible without accuracy loss. Algorithmically, the approach features a Jacobian-free Newton-Krylov solver. A main development in this study is the nonlinear elimination of the new-time particle variables (positions and velocities). Such nonlinear elimination, which we term particle enslavement, results in a nonlinear formulation with memory requirements comparable to those of a fluid computation, and affords us substantial freedom in regards to the particle orbit integrator. Numerical examples are presented that demonstrate the advertised properties of the scheme. In particular, long-time ion acoustic wave simulations show that numerical accuracy does not degrade even with very large implicit time steps, and that significant CPU gains are possible.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Mechanisms for the convergence of time-parallelized, parareal turbulent plasma simulations

Parareal is a recent algorithm able to parallelize the time dimension in spite of its sequential nature. It has been applied to several linear and nonlinear problems and, very recently, to a simulation of fully-developed, two-dimensional drift wave turbulence. The mere fact that parareal works in such a turbulent regime is in itself somewhat unexpected, due to the characteristic sensitivity of turbulence to any change in initial conditions. This fundamental property of any turbulent system should render the iterative correction procedure characteristic of the parareal method inoperative, but this seems not to be the case. In addition, the choices that must be made to implement parareal (division of the temporal domain, election of the coarse solver and so on) are currently made using trial-and-error approaches. Here, we identify the mechanisms responsible for the convergence of parareal of these simulations of drift wave turbulence. We also investigate which conditions these mechanisms impose on any successful parareal implementation. The results reported here should be useful to guide future implementations of parareal within the much wider context of fully-developed fluid and plasma turbulent simulations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-D-206-07: CBCT Scatter Correction Based On Rotating Collimator

Purpose: Scatter correction in cone-beam computed tomography (CBCT) has obvious effect on the removal of image noise, the cup artifact and the increase of image contrast. Several methods using a beam blocker for the estimation and subtraction of scatter have been proposed. However, the inconvenience of mechanics and propensity to residual artifacts limited the further evolution of basic and clinical research. Here, we propose a rotating collimator-based approach, in conjunction with reconstruction based on a discrete Radon transform and Tchebichef moments algorithm, to correct scatter-induced artifacts. Methods: A rotating-collimator, comprising round tungsten alloy strips, was mounted on a linear actuator. The rotating-collimator is divided into 6 portions equally. The round strips space is evenly spaced on each portion but staggered between different portions. A step motor connected to the rotating collimator drove the blocker to around x-ray source during the CBCT acquisition. The CBCT reconstruction based on a discrete Radon transform and Tchebichef moments algorithm is performed. Experimental studies using water phantom and Catphan504 were carried out to evaluate the performance of the proposed scheme. Results: The proposed algorithm was tested on both the Monte Carlo simulation and actual experiments with the Catphan504 phantom. From the simulation result, the mean square error of the reconstruction error decreases from 16% to 1.18%, the cupping (τcup) from 14.005% to 0.66%, and the peak signal-to-noise ratio increase from 16.9594 to 31.45. From the actual experiments, the induced visual artifacts are significantly reduced. Conclusion: We conducted an experiment on CBCT imaging system with a rotating collimator to develop and optimize x-ray scatter control and reduction technique. The proposed method is attractive in applications where a high CBCT image quality is critical, for example, dose calculation in adaptive radiation therapy. We want to thank Dr. Lei Xing and Dr. Yong Yang in the Stanford University School of Medicine for this work. This work was jointly supported by NSFC (61471226), Natural Science Foundation for Distinguished Young Scholars of Shandong Province (JQ201516), and China Postdoctoral Science Foundation (2015T80739, 2014M551949).

60 APPLIED LIFE SCIENCES↗

Projection-Based Linear Constrained Estimation and Fusion over Long-Haul Links

In this work, we study estimation and fusion with linear dynamics in long-haul sensor networks, wherein a number of sensors are remotely deployed over a large geographical area for performing tasks such as target tracking, and a remote fusion center serves to combine the information provided by these sensors in order to improve the overall tracking accuracy. In reality, the motion of a dynamic target might be subject to certain constraints, for instance, those defined by a road network. We explore the accuracy performance of projection-based constrained estimation and fusion methods that is affected by information loss over the long-haul links. We use a tracking example to compare the tracking errors under various implementations of centralized and distributed projection-based estimation and fusion methods.

Rao, Nageswara S↗

SU-D-210-05: The Accuracy of Raw and B-Mode Image Data for Ultrasound Speckle Tracking in Radiation Therapy

Purpose: For ultrasound speckle tracking there is some evidence that the envelope-detected signal (the main step in B-mode image formation) may be more accurate than raw ultrasound data for tracking larger inter-frame tissue motion. This study investigates the accuracy of raw radio-frequency (RF) versus non-logarithmic compressed envelope-detected (B-mode) data for ultrasound speckle tracking in the context of image-guided radiation therapy. Methods: Transperineal ultrasound RF data was acquired (with a 7.5 MHz linear transducer operating at a 12 Hz frame rate) from a speckle phantom moving with realistic intra-fraction prostate motion derived from a commercial tracking system. A normalised cross-correlation template matching algorithm was used to track speckle motion at the focus using (i) the RF signal and (ii) the B-mode signal. A range of imaging rates (0.5 to 12 Hz) were simulated by decimating the imaging sequences, therefore simulating larger to smaller inter-frame displacements. Motion estimation accuracy was quantified by comparison with known phantom motion. Results: The differences between RF and B-mode motion estimation accuracy (2D mean and 95% errors relative to ground truth displacements) were less than 0.01 mm for stable and persistent motion types and 0.2 mm for transient motion for imaging rates of 0.5 to 12 Hz. The mean correlation for all motion types and imaging rates was 0.851 and 0.845 for RF and B-mode data, respectively. Data type is expected to have most impact on axial (Superior-Inferior) motion estimation. Axial differences were <0.004 mm for stable and persistent motion and <0.3 mm for transient motion (axial mean errors were lowest for B-mode in all cases). Conclusions: Using the RF or B-mode signal for speckle motion estimation is comparable for translational prostate motion. B-mode image formation may involve other signal-processing steps which also influence motion estimation accuracy. A similar study for respiratory-induced motion would also be prudent. This work is support by Cancer Research UK Programme Grant C33589/A19727.

60 APPLIED LIFE SCIENCES↗

Short-Term Forecasting of Electric Loads Using Nonlinear Autoregressive Artificial Neural Networks with Exogenous Vector Inputs

Short-term load forecasting is crucial for the operations planning of an electrical grid. Forecasting the next 24 h of electrical load in a grid allows operators to plan and optimize their resources. The purpose of this study is to develop a more accurate short-term load forecasting method utilizing non-linear autoregressive artificial neural networks (ANN) with exogenous multi-variable input (NARX). The proposed implementation of the network is new: the neural network is trained in open-loop using actual load and weather data, and then, the network is placed in closed-loop to generate a forecast using the predicted load as the feedback input. Unlike the existing short-term load forecasting methods using ANNs, the proposed method uses its own output as the input in order to improve the accuracy, thus effectively implementing a feedback loop for the load, making it less dependent on external data. Using the proposed framework, mean absolute percent errors in the forecast in the order of 1% have been achieved, which is a 30% improvement on the average error using feedforward ANNs, ARMAX and state space methods, which can result in large savings by avoiding commissioning of unnecessary power plants. The New England electrical load data are used to train and validate the forecast prediction.

30 DIRECT ENERGY CONVERSION↗

A fast and robust computational modeling approach for density and shape predictions in powder metallurgy hot isostatic pressing

Powder metallurgy hot isostatic pressing (PM-HIP) is an advanced manufacturing process that produces near-net-shape parts with high material utilization and uniform microstructures. PM-HIP is frequently used for producing small-scale parts with complicated geometries and is potentially economical for producing large-scale parts. However, excessive post-HIP shape distortions can reduce its effectiveness and economic advantage, especially for larger parts. A PM-HIP computational model can predict and help mitigate these distortions. However, due to complex deformation mechanisms and thermo-mechanical coupling present in PM-HIP processes, these non-linear computational models sometimes become numerically unstable. The numerical instabilities in these models can lead to very slow convergence or no convergence at all, which often translates to slow and unreliable models. These limitations are more pronounced in large models with complicated geometries. Hence, in this work, an alternative modeling approach is presented that improves numerical stability and computational performance. The presented approach achieves these improvements through approximating the fully coupled thermo-mechanical PM-HIP model as a decoupled model and adding inertial damping to the model’s mechanical part. In conclusion, a comparison with the fully coupled model indicated a slight dip in prediction accuracy (<5% error) but significant improvements in numerical stability (>20 times larger time step size) and computational performance (5-10 times speed-up with less computational resource usage) when using the presented approach.

Hot isostatic pressing↗

Bathymetric Influences on Antarctic Ice-Shelf Melt Rates

Ocean bathymetry exerts a strong control on ice sheet-ocean interactions within Antarctic ice-shelf cavities, where it can limit the access of warm, dense water at depth to the underside of floating ice shelves. However, ocean bathymetry is challenging to measure within or close to ice-shelf cavities. It remains unclear how uncertainty in existing bathymetry datasets affect simulated sub-ice-shelf melt rates. In this work, we infer linear sensitivities of ice-shelf melt rates to bathymetric shape with grid-scale detail by means of the adjoint of an ocean general circulation model. Both idealized and realistic-geometry experiments of sub-ice-shelf cavities in West Antarctica reveal that bathymetry has a strong impact on melt in localized regions such as topographic obstacles to flow. Moreover, response of melt to bathymetric perturbation is found to be non-monotonic, with deepening leading to either increased or decreased melt depending on location. Our computational approach provides a comprehensive way of identifying regions, where refined knowledge of bathymetry is most impactful, and also where bathymetric errors have relatively little effect on modeled ice sheet-ocean interactions.

54 ENVIRONMENTAL SCIENCES↗

Neural network based fast prediction of β N limits in HL-2M

Artificial neural networks (NNs) are trained, based on the numerical database, to predict the no-wall and ideal-wall β N limits, due to onset of the n = 1 ( n is the toroidal mode number) ideal external kink instability, for the HL-2M tokamak. The database is constructed by toroidal computations utilizing both the equilibrium code CHEASE (Lütjens et al 1992 Comput. Phys. Commun. 69 287) and the stability code MARS-F (Liu et al 2000 Phys. Plasmas 7 3681). The stability results show that (1) the plasma elongation generally enhances both β N limits, for either positive or negative triangularity plasmas; (2) the effect is more pronounced for positive triangularity plasmas; (3) the computed no-wall β N limit linearly scales with the plasma internal inductance, with the proportionality coefficient ranging between 1 and 5 for HL-2M; (4) the no-wall limit substantially decreases with increasing pressure peaking factor. Furthermore, both the NN model and the convolutional neural network (CNN) model are trained and tested, producing consistent results. The trained NNs predict both the no-wall and ideal-wall limits with as high as 95% accuracy, compared to those directly computed by the stability code. Additional test cases, produced by the Tokamak Simulation Code (Jardin et al 1993 Nucl. Fusion 33 371), also show reasonable performance of the trained NNs, with the relative error being within 10%. The constructed database provides effective references for the future HL-2M operations. The trained NNs can be used as a real-time monitor for disruption prevention in the HL-2M experiments, or serve as part of the integrated modeling tools for ideal kink stability analysis.

Physics↗

Advanced Quantum Poisson Solver in the NISQ era

The Poisson equation has many applications across the broad areas of science and engineering. Most quantum algorithms for the Poisson solver presented so far, either suffer from lack of accuracy and/or are limited to very small sizes of the problem, and thus have no practical usage. Here we present an advanced quantum algorithm for solving the Poisson equation with high accuracy and dynamically tunable problem size. After converting the Poisson equation to the linear systems through the finite difference method, we adopt the Harrow-Hassidim-Lloyd (HHL) algorithm as the basic framework. Particularly, in this work we present an advanced circuit that ensures the accuracy of the solution by implementing non-truncated eigenvalues through eigenvalue amplification as well as by increasing the accuracy of the controlled rotation angular coefficients, which are the critical factors in the HHL algorithm. We show that our algorithm not only increases the accuracy of the solutions, but also composes more practical and scalable circuits by dynamically controlling problem size in the NISQ devices. We present both simulated and experimental results, and discuss the sources of errors. Finally, we conclude that overall results on the quantum hardware are dominated by the error in the CNOT gates.

Robson, Walter↗

MO-FG-303-02: BEST IN PHYSICS (THERAPY): Cherenkov Emission Dosimetry: Feasibility for Electron Radiotherapy

Purpose: To investigate from first principles, corroborated by Monte Carlo simulations and experimental measurements, the feasibility of developing a relative Cherenkov emission (CE) dosimetry protocol for electron beam radiotherapy. Methods: Monte Carlo (MC) simulations of mono-energetic electrons incident on water were carried out in Geant4. Percent depth Cherenkov emission (PDCE) and dose (PDD) distributions were scored for incidence energies of 4, 6, 9, 12, 15, and 18 MeV. PDCE-to-PDD analytical conversion models were developed from least-squares data fits generated for PDD as a function of PDCE at the same depth and at different depths. Experimental techniques for validation of these models are examined. Results: Same-depth PDD versus PDCE data fits indicate that although the relationship is linear to first order (correlation r > 0.9 for all energies), it is much more accurately approximated by separate linear and quadratic models for the build-up and drop-off regions, respectively (r > 0.999), which is theoretically underpinned. To understand the source of this relationship and its basis for developing robust conversion models, an approximate quadratic first-principles model was derived and found in agreement with MC/measured data (20% deviation at worst). Conversely, data fits of PDD versus different-depth PDCE unveiled a depth-invariant effective point of measurement of 1.5–2.1 mm downstream with 4–18 MeV incidence, respectively (r > 0.999 in the drop-off region). We present an analytical first-principles justification for this shift. This method led to errors of <1% in drop-off region PDD (<2% for PDD<20% with 4 MeV incidence) and <0.2 mm in practical range prediction. Conclusion: We present robust quantitative prediction models, derived from first-principles and supported by simulation and measurement, for relative dose from Cherenkov emission by high-energy electrons. This constitutes a major step towards development of protocols for routine clinical quality assurance as well as real-time in vivo Cherenkov dosimetry in radiotherapy. The authors acknowledge partial support by Fonds de recherche du Quebec - Nature et technologies (FRQNT), CREATE Medical Physics Research Training Network grant of the Natural Sciences and Engineering Research Council of Canada (NSERC), CREATE Integrated Sensor Systems grant of NSERC, the Canadian Institutes of Health Research (CIHR), and NSERC.

60 APPLIED LIFE SCIENCES↗

Refine your search to explore more results.