Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Image Reconstruction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Reconstruction of the Hubble Space Telescope mirror figure from out-of-focus stellar images

Both the amplitude and the phase of the incoming wave front viewed from the focal plane are reconstructed from the illumination recorded in defocused stellar images taken in flight by the HST. The reconstructed wavefront surface shows very little aberration. Compared to geometrical optics methods, the technique produces high spatial resolution wavefront maps with images taken closer to the telescope's focal plane. For the HST, the quality of the wavefront reconstruction is limited by the telescope jitter. The technique cannot be applied to ground-based telescopes at optical wavelength where the image is heavily blurred by the atmosphere. It is argued to be promising as a diagnostic tool for optical telescopes in space.

Roddier, C.↗

X-ray scatter correction method for dedicated breast computed tomography

Purpose: To improve image quality and accuracy in dedicated breast computed tomography (BCT) by removing the x-ray scatter signal included in the BCT projections. Methods: The previously characterized magnitude and distribution of x-ray scatter in BCT results in both cupping artifacts and reduction of contrast and accuracy in the reconstructions. In this study, an image processing method is proposed that estimates and subtracts the low-frequency x-ray scatter signal included in each BCT projection postacquisition and prereconstruction. The estimation of this signal is performed using simple additional hardware, one additional BCT projection acquisition with negligible radiation dose, and simple image processing software algorithms. The high frequency quantum noise due to the scatter signal is reduced using a noise filter postreconstruction. The dosimetric consequences and validity of the assumptions of this algorithm were determined using Monte Carlo simulations. The feasibility of this method was determined by imaging a breast phantom on a BCT clinical prototype and comparing the corrected reconstructions to the unprocessed reconstructions and to reconstructions obtained from fan-beam acquisitions as a reference standard. One-dimensional profiles of the reconstructions and objective image quality metrics were used to determine the impact of the algorithm. Results: The proposed additional acquisition results in negligible additional radiation dose to the imaged breast ({approx}0.4% of the standard BCT acquisition). The processed phantom reconstruction showed substantially reduced cupping artifacts, increased contrast between adipose and glandular tissue equivalents, higher voxel value accuracy, and no discernible blurring of high frequency features. Conclusions: The proposed scatter correction method for dedicated breast CT is feasible and can result in highly improved image quality. Further optimization and testing, especially with patient images, is necessary to characterize its impact on clinical performance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Field of view extension and truncation correction for MR-based human attenuation correction in simultaneous MR/PET imaging

Purpose: In quantitative PET imaging, it is critical to accurately measure and compensate for the attenuation of the photons absorbed in the tissue. While in PET/CT the linear attenuation coefficients can be easily determined from a low-dose CT-based transmission scan, in whole-body MR/PET the computation of the linear attenuation coefficients is based on the MR data. However, a constraint of the MR-based attenuation correction (AC) is the MR-inherent field-of-view (FoV) limitation due to static magnetic field (B{sub 0}) inhomogeneities and gradient nonlinearities. Therefore, the MR-based human AC map may be truncated or geometrically distorted toward the edges of the FoV and, consequently, the PET reconstruction with MR-based AC may be biased. This is especially of impact laterally where the patient arms rest beside the body and are not fully considered. Methods: A method is proposed to extend the MR FoV by determining an optimal readout gradient field which locally compensates B{sub 0} inhomogeneities and gradient nonlinearities. This technique was used to reduce truncation in AC maps of 12 patients, and the impact on the PET quantification was analyzed and compared to truncated data without applying the FoV extension and additionally to an established approach of PET-based FoV extension. Results: The truncation artifacts in the MR-based AC maps were successfully reduced in all patients, and the mean body volume was thereby increased by 5.4%. In some cases large patient-dependent changes in SUV of up to 30% were observed in individual lesions when compared to the standard truncated attenuation map. Conclusions: The proposed technique successfully extends the MR FoV in MR-based attenuation correction and shows an improvement of PET quantification in whole-body MR/PET hybrid imaging. In comparison to the PET-based completion of the truncated body contour, the proposed method is also applicable to specialized PET tracers with little uptake in the arms and might reduce the computation time by obviating the need for iterative calculations of the PET emission data beyond those required for reconstructing images.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Wideband Fractal Antennas for Holographic Imaging and Rectenna Applications

At Pacific Northwest National Laboratory, wideband antenna arrays have been successfully used to reconstruct three-dimensional images at microwave and millimeter-wave frequencies. Applications of this technology have included portal monitoring, through-wall imaging, and weapons detection. Fractal antennas have been shown to have wideband characteristics due to their self-similar nature (that is, their geometry is replicated at different scales). They further have advantages in providing good characteristics in a compact configuration. We discuss the application of fractal antennas for holographic imaging. Simulation results will be presented. Rectennas are a specific class of antennas in which a received signal drives a nonlinear junction and is retransmitted at either a harmonic frequency or a demodulated frequency. Applications include tagging and tracking objects with a uniquely-responding antenna. It is of interest to consider fractal rectenna because the self-similarity of fractal antennas tends to make them have similar resonance behavior at multiples of the primary resonance. Thus, fractal antennas can be suited for applications in which a signal is reradiated at a harmonic frequency. Simulations will be discussed with this application in mind.

42 ENGINEERING↗

PyPhase – a Python package for X-ray phase imaging

X-ray propagation-based imaging techniques are well established at synchrotron radiation and laboratory sources. However, most reconstruction algorithms for such image modalities, also known as phase-retrieval algorithms, have been developed specifically for one instrument by and for experts, making the development and diffusion of such techniques difficult. Here, PyPhase, a free and open-source package for propagation-based near-field phase reconstructions, which is distributed under the CeCILL license, is presented. PyPhase implements some of the most popular phase-retrieval algorithms in a highly modular framework supporting its deployment on large-scale computing facilities. This makes the integration, the development of new phase-retrieval algorithms, and the deployment on different computing infrastructures straightforward. Its capabilities and simplicity are presented by application to data acquired at the synchrotron source MAX IV (Lund, Sweden).

36 MATERIALS SCIENCE↗

Optical boundary reconstruction of tokamak plasmas for feedback control of plasma position and shape

A new diagnostic is developed to reconstruct the plasma boundary using visible wavelength images. Exploiting the plasma's edge localized and toroidally symmetric emission profile, a new coordinate transform is presented to reconstruct the plasma boundary from a poloidal view image. The plasma boundary reconstruction is implemented in MATLAB and applied to camera images of Mega-Ampere Spherical Tokamak discharges. The optically reconstructed plasma boundaries are compared to magnetic reconstructions from the offline reconstruction code EFIT, showing very good qualitative and quantitative agreement. Average errors are within 2 cm and correlation is high. In the current software implementation, plasma boundary reconstruction from a single image takes 3 ms. The applicability and system requirements of the new optical boundary reconstruction, called OFIT, for use in both feedback control of plasma position and shape and in offline reconstruction tools are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optical-property coefficient estimation of bulky medium in experiments with a succinctly analytical calculation

Diffuse optical imaging enables to reconstruct distribution of optical properties, absorption and scattering coefficients, in tissue for breast cancer detection based on diffusion equation with the help of the initial guess obtained from measured data. To estimate the initial guess of the optical-property coefficients, an analytical solution of diffusion equation can be used and compared with the measured data. The analytical solution for a homogeneous infinite medium can be obtained in the frequency domain, expressing that the photon intensity and the phase lag relative to the distance between source and detector in a linear relationship. In this study, a succinct calculation using the trigonometric relation is proposed to estimate the optical-property coefficients. A tank-type and a cylinder Lipovenoes phantoms with two concentrations of 1.25% and 2.5% are employed and measured for verification. It is found that the method proposed here shows better results and results in estimation errors of 0–14.81% for μ{sub a} and 20–42% for μ{sub s}′.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Compared vulnerabilities to small cardiac motions between different cameras used for myocardial perfusion imaging

This phantom-based study was aimed to determine whether cardiac CZT-cameras, which provide an enhanced spatial resolution and image contrast compared to Anger cameras, are similarly affected by small cardiac motions. Translations of a left ventricular (LV) insert at half-SPECT acquisitions through six possible orthogonal directions and with 5- or 10-mm amplitude were simulated on the Discovery NM-530c and DSPECT CZT-cameras and on an Anger Symbia T2 camera equipped with an astigmatic (IQ.SPECT) or conventional parallel-hole collimator (Conv.SPECT). SPECT images were initially reconstructed as currently recommended for clinical routine. The heterogeneity in recorded activity from the 17 LV segments gradually increased between baseline and motions simulated at 5- and 10-mm amplitudes with all cameras, although being higher for Anger- than CZT-cameras at each step and resulting in a higher mean number of artifactual abnormal segments (at 10-mm amplitude, Conv.SPECT: 3.7; IQ.SPECT: 1.8, Discovery: 0.7, DSPECT: 0). However, this vulnerability to motion was markedly (1) decreased for Conv.SPECT reconstructed without the recommended Resolution Recovery algorithm and (2) increased for DSPECT reconstructed without the recommended cardiac model. CZT-cameras and especially the DSPECT appear less vulnerable to small cardiac motions than Anger-cameras although these differences are strongly dependent on reconstruction parameters.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A crystal plasticity-based study of the relationship between microstructure and ultra-high-cycle fatigue life in nickel titanium alloys

Nickel Titanium (NiTi) alloys are often used in biomedical devices where failure due to mechanical fatigue is common. For other alloy systems, computational models have proven an effective means of determining the relationship between microstructural features and fatigue life. This work will extend the subset of those models which were based on crystal plasticity to examine the relationship between microstructure and fatigue life in NiTi alloys. It will explore the interaction between a spherical inclusion and the material’s free surface along with several NiTi microstructures reconstructed from 3D imaging. This work will determine the distance at which the free surface interacts with an inclusion and the effect of applied strain of surface-inclusion interaction. The effects of inclusion-inclusion interaction, matrix voiding, and matrix strengthening are explored and ranked with regards to their influence on fatigue life.

36 MATERIALS SCIENCE↗

Dynamic Collimator Angle Adjustments During Volumetric Modulated Arc Therapy to Account for Prostate Rotations

Purpose: Rotations of the prostate gland induce considerable geometric uncertainties in prostate cancer radiation therapy. Collimator and gantry angle adjustments can correct these rotations in intensity modulated radiation therapy. Modern volumetric modulated arc therapy (VMAT) treatments, however, include a wide range of beam orientations that differ in modulation, and corrections require dynamic collimator rotations. The aim of this study was to implement a rotation correction strategy for VMAT dose delivery and validate it for left-right prostate rotations. Methods and Materials: Clinical VMAT treatment plans of 5 prostate cancer patients were used. Simulated left-right prostate rotations between +15° and −15° were corrected by collimator rotations. We compared corrected and uncorrected plans by dose volume histograms, minimum dose (D{sub min}) to the prostate, bladder surface receiving ≥78 Gy (S78) and rectum equivalent uniform dose (EUD; n=0.13). Each corrected plan was delivered to a phantom, and its deliverability was evaluated by γ-evaluation between planned and delivered dose, which was reconstructed from portal images acquired during delivery. Results: On average, clinical target volume minimum dose (D{sub min}) decreased up to 10% without corrections. Negative left-right rotations were corrected almost perfectly, whereas D{sub min} remained within 4% for positive rotations. Bladder S78 and rectum EUD of the corrected plans matched those of the original plans. The average pass rate for the corrected plans delivered to the phantom was 98.9% at 3% per 3 mm gamma criteria. The measured dose in the planning target volume approximated the original dose, rotated around the simulated left-right angle, well. Conclusions: It is feasible to dynamically adjust the collimator angle during VMAT treatment delivery to correct for prostate rotations. This technique can safely correct for left-right prostate rotations up to 15°.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Machine learning-assisted upscaling analysis of reservoir rock core properties based on micro-computed tomography imagery

Optimum solutions for geologic modeling and reservoir simulation in industries such as oil and gas recovery and carbon capture and storage require accurate characterization of reservoir properties, which are often heterogeneous. In this study, high-quality micro-computed tomography (CT) images (1.475-μm/pixel resolution) of a sandstone core acquired from the Bell Creek oil field, USA, were used to provide nondestructive analysis of pore- and core-scale heterogeneity across measurement scales of 94–566 μm. In addition to characterizing the as-received sample, the core sample was flooded with brine to evaluate the capacity of the core sample to receive injected fluids. The micro-CT images were systematically segmented into pore spaces and grains via machine learning (ML) steps including image preprocessing, label creation using a traditional ML method based on limited manual image annotation, and finally U-Net segmentation. The segmented image stacks were reconstructed into digital cubes of various scales of voxel lengths. The 3D porosity values were calculated for all the digital cubes, and the fractal dimensions of the cubes were estimated using a box-counting method. The results showed that smaller cubes had greater heterogeneity and that the porosity values could be accurately estimated by fractal dimension and voxel lengths using ML models. For the core sample with brine flooding, the ratio of pores filled by brine to the total pore space was related to the porosity and could also be accurately estimated by porosity, fractal dimension, and voxel lengths using ML models. In conclusion, the results of this study demonstrate that the concept of fractal dimension can be a useful vector to perform upscaling analysis of sandstone rock heterogeneity from the pore to core scale and that fractal dimensions can be used to estimate porosity values and pore space-filling capacity across those scales.

58 GEOSCIENCES↗

Removing Stripes, Scratches, and Curtaining with Nonrecoverable Compressed Sensing

Highly-directional image artifacts such as ion mill curtaining, mechanical scratches, or image striping from beam instability degrade the interpretability of micrographs. These unwanted, aperiodic features extend the image along a primary direction and occupy a small wedge of information in Fourier space. Deleting this wedge of data replaces stripes, scratches, or curtaining, with more complex streaking and blurring artifacts—known within the tomography community as “missing wedge” artifacts. Here, we overcome this problem by recovering the missing region using total variation minimization, which leverages image sparsity-based reconstruction techniques—colloquially referred to as compressed sensing (CS)—to reliably restore images corrupted by stripe-like features. Our approach removes beam instability, ion mill curtaining, mechanical scratches, or any stripe features and remains robust at low signal-to-noise. In conclusion, the success of this approach is achieved by exploiting CS's inability to recover directional structures that are highly localized and missing in Fourier Space.

47 OTHER INSTRUMENTATION↗

3D Volumetric Structural Hierarchy Induced by Colloidal Polymerization of a Quantum-Dot Ionic Liquid Monomer Conjugate

Hierarchically structured emissive quantum dot (CdS/CdSe) poly(ionic liquid) composites are synthesized through colloidal polymerization within a lyotropic liquid crystal, yielding a solvent-responsive nanoparticle (NP) composite possessing four ordered structural motifs. The composite is prepared by coassembling an amphiphilic ionic liquid (IL) monomer, 3-decyl-1-vinylimidazolium chloride, [C 10 VIm + ][Cl - ], and IL monomer, 3-(10-mercaptodecyl)-1-vinylimidazolium bromide surface-functionalized quantum dots, QD-[SC 10 VIm + ][Br - ], in 30 wt % water. Photo (UV)-initiated free radical polymerization serves to form a colloidal copolymer that collimates pairs of QDs within the core of large cylinders (average diameter = 21 nm and length = 422 nm), as evidenced by ultrasmall-angle X-ray scattering (USAXS). As revealed by continuous wave terahertz multispectral reconstructive 3-D imaging, the subsurface structure along the cylinder axis undergoes dynamic rearrangement between 2D hexagonal and cubic packing. The polymerized ionic liquid sheath surrounding the QDs is composed of concentric hexagonally perforated lamellae (HPL) with an interlamellar repeat distance of 3 nm, as determined by small-angle X-ray scattering (SAXS). The encapsulated QDs retain crystallinity (TEM and WAXS) and emission characteristics (photoluminescence spectroscopy, lambda(EM) = 638 nm). Phenomenological time-dependent Ginzburg-Landau calculations verify the mesoscale cylinders arise from the topological constraints imposed by the in-plane perforations of the polymerized ionic liquid as it wraps around the hard (unmalleable) spherical QDs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Complete Strain Mapping of Nanosheets of Tantalum Disulfide

Quasi-two-dimensional (quasi-2D) materials hold promise for future electronics because of their unique band structuresthat result in electronic and mechanical properties sensitive to crystal strains in all three dimensions. Quantifying crystal strain is a prerequisite to correlating it with the performance of the device, and calls for high resolution but spatially resolved rapid characterization methods. Here we show that using fly-scan nano X-ray diffraction we can accomplish a tensile strain sensitivity below 0.001% with a spatial resolution of better than 80 nm over a spatial extent of 100 µm on quasi 2D flakes of 1T-TaS2. Coherent diffraction patterns were collected from a ~100 nm thick sheet of 1T-TaS2 by scanning 12keV focused X-ray beam across and rotating the sample. We demonstrate that the strain distribution around micron and sub-micron sized ‘bubbles’ that are present in the sample may be reconstructed from these images. The experiments use state of the art synchrotron instrumentation, and will allow rapid and non-intrusive strain mapping of thin film samples and electronic devices based on quasi 2D materials.

nano X-ray diffraction↗

Near-field examination of perovskite-based superlenses and superlens-enhanced probe-object coupling

A planar slab of negative-index material works as a superlens with sub-diffraction-limited resolution, as propagating waves are focused and, moreover, evanescent waves are reconstructed in the image plane. Here we demonstrate a superlens for electric evanescent fields with low losses using perovskites in the mid-infrared regime. The combination of nearfield microscopy with a tunable free-electron laser allows us to address precisely the polariton modes, which are critical for super-resolution imaging. We spectrally study the lateral and vertical distributions of evanescent waves around the image plane of such a lens, and achieve imaging resolution of λ/14 at the superlensing wavelength. Interestingly, at certain distances between the probe and sample surface, we observe a maximum of these evanescent fields. Comparisons with numerical simulations indicate that this maximum originates from an enhanced coupling between probe and object, which might be applicable for multifunctional circuits, infrared spectroscopy and thermal sensors.

36 MATERIALS SCIENCE↗

Improved sliced velocity map imaging apparatus optimized for H photofragments

Time-sliced velocity map imaging (SVMI), a high-resolution method for measuring kinetic energy distributions of products in scattering and photodissociation reactions, is challenging to implement for atomic hydrogen products. We describe an ion optics design aimed at achieving SVMI of H fragments in a broad range of kinetic energies (KE), from a fraction of an electronvolt to a few electronvolts. In order to enable consistently thin slicing for any imaged KE range, an additional electrostatic lens is introduced in the drift region for radial magnification control without affecting temporal stretching of the ion cloud. Time slices of {approx}5 ns out of a cloud stretched to Greater-Than-Or-Slanted-Equal-To 50 ns are used. An accelerator region with variable dimensions (using multiple electrodes) is employed for better optimization of radial and temporal space focusing characteristics at each magnification level. The implemented system was successfully tested by recording images of H fragments from the photodissociation of HBr, H{sub 2}S, and the CH{sub 2}OH radical, with kinetic energies ranging from <0.4 eV to >3 eV. It demonstrated KE resolution Less-Than-Or-Equivalent-To 1%-2%, similar to that obtained in traditional velocity map imaging followed by reconstruction, and to KE resolution achieved previously in SVMI of heavier products. We expect it to perform just as well up to at least 6 eV of kinetic energy. The tests showed that numerical simulations of the electric fields and ion trajectories in the system, used for optimization of the design and operating parameters, provide an accurate and reliable description of all aspects of system performance. This offers the advantage of selecting the best operating conditions in each measurement without the need for additional calibration experiments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Inversion of infrared imaging bolometer based on one-dimensional and three-dimensional modeling in HL-2A

Linear regularization has been applied to the HL-2A infrared imaging bolometer to reconstruct local plasma emission with one-dimensional (1D) and three-dimensional (3D) modeling under the assumption of toroidal symmetry. In the 3D modeling, a new method to calculate the detector point response function is introduced. This method can be adapted to an arbitrarily shaped pinhole. With the full 3D treatment of the detector geometry, up to 50% of the mean-squared error is reduced compared with the 1D modeling. This is attributed to the effects of finite detector size being taken into account in the 3D modeling. Meanwhile, the number of the bolometer pixels has been optimized to 20 × 20 by making a trade-off between the number of bolometer pixels and the sensitivity of the system. The plasma radiated power density distributions have been calculated as a demonstration using 1D modeling and 3D modeling, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Refine your search to explore more results.