Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Image Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

A Global Analysis of Wildfire Smoke Injection Heights Derived from Space-Based Multi-Angle Imaging

We present an analysis of over 23,000 globally distributed wildfire smoke plume injection heights derived from Multi-angle Imaging SpectroRadiometer (MISR) space-based, multi-angle stereo imaging. Both pixel-weighted and aerosol optical depth (AOD)-weighted results are given, stratified by region, biome, and month or season. This offers an observational resource for assessing first-principle plume-rise modelling, and can provide some constraints on smoke dispersion modelling for climate and air quality applications. The main limitation is that the satellite is in a sun-synchronous orbit, crossing the equator at about 10:30 a.m. local time on the day side. Overall, plumes occur preferentially during the northern mid-latitude burning season, and the vast majority inject smoke near-surface. However, the heavily forested regions of North and South America, and Africa produce the most frequent elevated plumes and the highest AOD values; some smoke is injected to altitudes well above 2 km in nearly all regions and biomes. Planetary boundary layer (PBL) versus free troposphere injection is a critical factor affecting smoke dispersion and environmental impact, and is affected by both the smoke injection height and the PBL height; an example assessment is made here, but constraining the PBL height for this application warrants further work.

Val Martin, Maria↗

Coronal fine structure as seen in the Skylab white light coronagraph

The white light coronograph (WLC) on Skylab provided an opportunity to study the corona at high spatial and temporal resolution. The spatial resolution of the instrument was approximately 25 cm with images taken approximately one per min. One set of images taken over a 10 min period was digitized, providing ten high spatial resolution images for analysis. The progress in data processing techniques available at the time was not sufficient to permit a reliable study of the fine structure in these images. Using current techniques an investigation of the sizes and lifetimes of the smallest scale features in the data was carried out. A preliminary analysis of an area between 2 and 3 Ro was completed. The results show that very narrow rays extend from at least 2 to 3 Ro. The narrowest of these rays has a thickness of approximately 75 cm. The contrast is so low that they are very close to the noise limit of the data. Most of the rays observed become unrecognizable after 10 min, although some remain visible over the entire time. Some notion seems to be detectable in the fine structure rays, but analysis of more frames will be needed to quantify these results.

Poland, Arthur I.↗

STEM Characterization of Dislocation Loops in Irradiated FCC Alloys

In this study, we demonstrate the methodology systematically developed for dislocation loop (perfect and faulted loops) imaging and analysis in irradiated face-centered-cubic (FCC) alloys using scanning transmission electron microscopy (STEM). On-zone [001] STEM imaging was identified as the preferred choice for its accuracy and effectiveness based on the comparison with other dislocation loop imaging techniques including: (i) on-zone STEM imaging using other major low-index zone axes, (ii) kinematic two-beam conditions bright field imaging near the [001] zone axis in conventional TEM (CTEM) mode, and (iii) Rel-Rod CTEM dark-field (DF) imaging near the [011] zone axis. The effect of STEM collection angle on the contrast formation of dislocation loops was also investigated. The developed method was confirmed by imaging all populations of perfect and faulted loops of types a/2$\langle$110$\rangle${110} and a/3$\langle$111$\rangle${111} found in an ion irradiated Ni40Fe40Cr20 alloy. The proposed STEM-based technique can easily identify said loops with a size greater than 10 nm without any assumptions such as those commonly made using the conventional Rel-Rod CTEM-DF technique. The recommended methodology in this study is developed as a quick and convenient tool that can be generally applied to irradiated FCC-based materials due to their common crystallography.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Image quality comparison between single energy and dual energy CT protocols for hepatic imaging

Purpose: Multi-detector computed tomography (MDCT) enables volumetric scans in a single breath hold and is clinically useful for hepatic imaging. For simple tasks, conventional single energy (SE) computed tomography (CT) images acquired at the optimal tube potential are known to have better quality than dual energy (DE) blended images. However, liver imaging is complex and often requires imaging of both structures containing iodinated contrast media, where atomic number differences are the primary contrast mechanism, and other structures, where density differences are the primary contrast mechanism. Hence it is conceivable that the broad spectrum used in a dual energy acquisition may be an advantage. In this work we are interested in comparing these two imaging strategies at equal-dose and more complex settings. Methods: We developed numerical anthropomorphic phantoms to mimic realistic clinical CT scans for medium size and large size patients. MDCT images based on the defined phantoms were simulated using various SE and DE protocols at pre- and post-contrast stages. For SE CT, images from 60 kVp through 140 with 10 kVp steps were considered; for DE CT, both 80/140 and 100/140 kVp scans were simulated and linearly blended at the optimal weights. To make a fair comparison, the mAs of each scan was adjusted to match the reference radiation dose (120 kVp, 200 mAs for medium size patients and 140 kVp, 400 mAs for large size patients). Contrast-to-noise ratio (CNR) of liver against other soft tissues was used to evaluate and compare the SE and DE protocols, and multiple pre- and post-contrasted liver-tissue pairs were used to define a composite CNR. To help validate the simulation results, we conducted a small clinical study. Eighty-five 120 kVp images and 81 blended 80/140 kVp images were collected and compared through both quantitative image quality analysis and an observer study. Results: In the simulation study, we found that the CNR of pre-contrast SE image mostly increased with increasing kVp while for post-contrast imaging 90 kVp or lower yielded higher CNR images, depending on the differential iodine concentration of each tissue. Similar trends were seen in DE blended CNR and those from SE protocols. In the presence of differential iodine concentration (i.e., post-contrast), the CNR curves maximize at lower kVps (80–120), with the peak shifted rightward for larger patients. The combined pre- and post-contrast composite CNR study demonstrated that an optimal SE protocol has better performance than blended DE images, and the optimal tube potential for SE scan is around 90 kVp for a medium size patients and between 90 and 120 kVp for large size patients (although low kVp imaging requires high x-ray tube power to avoid photon starvation). Also, a tin filter added to the high kVp beam is not only beneficial for material decomposition but it improves the CNR of the DE blended images as well. The dose adjusted CNR of the clinical images also showed the same trend and radiologists favored the SE scans over blended DE images. Conclusions: Our simulation showed that an optimized SE protocol produces up to 5% higher CNR for a range of clinical tasks. The clinical study also suggested 120 kVp SE scans have better image quality than blended DE images. Hence, blended DE images do not have a fundamental CNR advantage over optimized SE images.

60 APPLIED LIFE SCIENCES↗

Segmentation of tomography datasets using 3D convolutional neural networks

Dendritic microstructures are ubiquitous in nature and are the primary solidification morphologies in metallic materials. Techniques such as X-ray computed tomography (XCT) have provided new insights into dendritic phase transformation phenomena. However, manual identification of dendritic morphologies in microscopy data can be both labor intensive and potentially ambiguous. The analysis of 3D datasets is particularly challenging due to their large sizes (terabytes) and the presence of artifacts scattered within the imaged volumes. Here, in this study, we trained 3D convolutional neural networks (CNNs) to segment 3D datasets. Three CNN architectures were investigated, including a new version of FCDenseNet which we extended to 3D. We show that using hyperparameter optimization (HPO) and fine-tuning techniques, both 2D and 3D CNN architectures outperform the previous state of the art. The 3D U-Net architecture trained in this study produced the best segmentations according to quantitative metrics (intersection-over-union of 95.56% and a boundary displacement error of 0.58 pixels), while 3D FCDense produced the smoothest boundaries and best segmentations according to visual inspection. The trained 3D CNNs are able to segment entire 852 × 852 × 250 voxel 3D volumes in only ~60 s, thus hastening the progress towards a deeper understanding of phase transformation phenomena such as dendritic solidification.

36 MATERIALS SCIENCE↗

Health-Related Quality of Life in Locally Advanced Cervical Cancer Patients After Definitive Chemoradiation Therapy Including Image Guided Adaptive Brachytherapy: An Analysis From the EMBRACE Study

Purpose: This study analyzed functioning and symptom scores for longitudinal quality of life (QoL) from patients with locally advanced cervical cancer who underwent definitive chemoradiation therapy with image guided adaptive brachytherapy in the EMBRACE study. Methods and Materials: In total, 744 patients at a median follow-up of 21 months were included. QoL was prospectively assessed using European Organization for Research and Treatment of Cancer Quality of Life core module 30 (EORTC QLQ-C30) and EORTC cervical cancer module 24 (CX24) questionnaires at baseline, then every 3 months during the first year, every 6 months in the second and third years, and finally yearly thereafter in patients with no evidence of disease. Outcomes were evaluated over time and compared to those from an age-matched female reference population. Results: General QoL and emotional and social functioning were impaired at baseline but improved during the first 6 months after treatment, to reach a level comparable to that of the reference population, whereas cognitive functioning remained impaired. Both social and role functioning showed the lowest scores at baseline but which increased after treatment to reach a plateau at 6 months and then declined slightly at 3 and 4 years. The overall symptom experience was elevated at baseline and decreased to a level within the range of that of the reference population. Similarly, tumor-related symptoms (eg, pain, appetite loss, and constipation), which were present before treatment, decreased substantially at the first follow-up after treatment. Several treatment-related symptoms developed either immediately after and persisted over time (diarrhea, menopausal symptoms, peripheral neuropathy, and sexual functioning problems) or developed gradually after treatment (lymphedema and dyspnea). Conclusions: This longitudinal prospective QoL analysis showed that patients' general QoL and functioning were impaired before treatment compared to those of reference data. Several tumor-related symptoms resolved after treatment, and functioning and general QoL returned to that of the level of the reference population, indicating a transient impact of diagnosis and treatment. However, several treatment-related symptoms and problems did develop and persist, either immediately or gradually after treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Information-Theoretic Exploration of Multivariate Time-Varying Image Databases

Modern scientific simulations produce very large datasets, making interactive exploration of such data computationally prohibitive. An increasingly common data reduction technique is to store visualizations and other data extracts in a database. The Cinema project is one such approach, storing visualizations in an image database for post hoc exploration and interactive image-based analysis. This work focuses on developing efficient algorithms that can quantify various types of multivariate dependencies existing within multi-variable datasets. It applies specific mutual information measures for the quantification of salient regions from multivariate image data. Here, using such information measures, the opacity of the images is modulated so that the salient regions are automatically highlighted and the domain scientists can interactively explore the most relevant regions for scientific discovery.

97 MATHEMATICS AND COMPUTING↗

Quantification of morphological change in materials based on image data utilizing machine learning techniques

Computed tomography (CT) resolution has become high enough to monitor morphological changes due to aging in materials in long-term applications. We explored the utility of the critic of a generative adversarial network (GAN) to automatically detect such changes. The GAN was trained with images of pristine Pharmatose, which is used as a surrogate energetic material. It is important to note that images of the material with altered morphology were only used during the test phase. The GAN-generated images visually reproduced the microstructure of Pharmatose well, although some unrealistic particle fusion was seen. Calculated morphological metrics (volume fraction, interfacial line length, and local thickness) for the synthetic images also showed good agreement with the training data, albeit with signs of mode collapse in the interfacial line length. While the critic exposed changes in particle size, it showed limited ability to distinguish images by particle shape. The detection of shape differences was also a more challenging task for the selected morphological metrics that related to energetic material performance. We further tested the critic with images of aged Pharmatose. Subtle changes due to aging are difficult for the human analyst to detect. Both critic and morphological metrics analysis showed image differentiation.

36 MATERIALS SCIENCE↗

Utilization of the Critic Subnetwork of a Generative Adversarial Network as Detector of Morphological Material Change in Image Data

The resolution of computed tomography (CT) has become high enough to monitor morphological changes due to aging in materials in long-term applications. For this work, we explored the utility of the critic of a generative adversarial network (GAN) to automatically detect such changes. The GAN was trained with images of pristine Pharmatose, which is used as a surrogate energetic material. It is important to note that images of the material with altered morphology were only used during the test phase. The GAN-generated images reproduced the microstructure of Pharmatose well, although some unrealistic particle fusion was seen. Calculated morphological metrics (volume fraction, interfacial line length, and local thickness) for the synthetic images also showed good agreement with the training data, albeit with signs of mode collapse in the interfacial line length. While the critic exposed changes in particle size, it showed limited ability to distinguish images by particle shape. The detection of shape differences was also a more challenging task for the selected morphological metrics that related to energetic material performance. We further tested the critic with images of aged Pharmatose. Subtle changes due to aging are difficult for the human analyst to detect; but both critic and morphological metrics analysis showed image differentiation.

36 MATERIALS SCIENCE↗

The performance of additively manufactured Haynes 282 in supercritical CO 2

The use of supercritical carbon dioxide (sCO 2 ) as a working fluid is garnering interest in next generation power production systems due to the possibility of increased operational efficiencies and lower associated costs. Its implementation requires alloys with excellent high temperature strength and corrosion resistance, which makes Haynes 282® (H282) a suitable candidate. With increasing adoption of additive manufacturing (AM) in the energy industry, there is a need to investigate long-term sCO2 exposure on AM produced materials. Additively manufactured H282 (AM-H282) samples built using laser powder bed fusion in two different orientations were analyzed through imaging, gravimetric analysis, and room-temperature tensile testing before and after 1000-h exposure to CO 2 at 750 °C and 20 MPa. Performed imaging included observation of the sample surfaces and of the material bulk (cross sections) through means of Scanning Electron Microscopy (SEM) and optical microscopy. In comparison to wrought H282, it was found that the exposed material exhibited a similar Cr 2 O 3 oxide protective layer about 2 μm in thickness with additional top-surface TiO 2 oxide and carbon-rich precipitates. It was also similarly observed that internal oxidation was present but limited to a depth of 20 μm, and a 1–3 μm γ’ denuded region appeared to surround all internal and surface oxidation. Thermal aging effects were noted with the precipitation of needle-like structures in the γ/γ’ matrix and a coarsening of the γ’ precipitates from 28 nm to 73 nm. Mass measurements analyzing oxide precipitation revealed a larger increase compared to wrought, representing an approximate 20% difference. Tensile testing results showed similar behavior to wrought with a slight increase in yield strength and a large reduction in elongation in the exposed samples.

36 MATERIALS SCIENCE↗

Measurement of Transport Properties of Woody Biomass Feedstock Particles Before and After Pyrolysis by Numerical Analysis of X-Ray Tomographic Reconstructions

Lignocellulosic biomass has a complex, species-specific microstructure that governs heat and mass transport during conversion processes. A quantitative understanding of the evolution of pore size and structure is critical to optimize conversion processes for biofuel and bio-based chemical production. Further, improving our understanding of the microstructure of biochar coproduct will accelerate development of its myriad applications. This work quantitatively compares the microstructural features and the anisotropic permeabilities of two woody feedstocks, red oak and Douglas fir, using X-ray computed tomography (XCT) before and after the feedstocks are subjected to pyrolysis. Quantitative analysis of the three-dimensional (3D) reconstructions allows for direct calculations of void fractions, pore size distributions and tortuosity factors. Next, 3D images are imported into an immersed boundary based finite volume solver to simulate gas flow through the porous structure and to directly calculate the principal permeabilities along longitudinal, radial, and tangential directions. The permeabilities of native biomass are seen to differ by three to four orders of magnitude in the different principal directions, but we find that this anisotropy is substantially reduced in the biochar formed during pyrolysis. The quantitative transport properties reported here enhance the ability of pyrolysis simulations to account for feedstock-specific effects and thereby provide a useful touchstone for the biorefining community.

09 BIOMASS FUELS↗

Software techniques for image processing

The present paper describes several software techniques that can be used to get the 'most' out of an image without destroying or adding any information. A simple overview is given of a general image-processing system, a number of systems in current use are listed, and three types of processing tasks are delineated: image diagnostics, subjective enhancement, and quantitative restoration. Examples of each of these types are discussed in some detail, including histogram, differences, and Fourier analysis for image diagnostics; contrast stretching, edge enhancement, and pseudocolor displays for subjective enhancement; and photometric correction, contouring, and geometric correction for quantitative restoration.

Klinglesmith, D. A.↗

WE-G-204-07: Automated Characterization of Perceptual Quality of Clinical Chest Radiographs: Improvements in Lung, Spine, and Hardware Detection

Purpose: To develop and validate more robust methods for automated lung, spine, and hardware detection in AP/PA chest images. This work is part of a continuing effort to automatically characterize the perceptual image quality of clinical radiographs. [Y. Lin et al. Med. Phys. 39, 7019–7031 (2012)] Methods: Our previous implementation of lung/spine identification was applicable to only one vendor. A more generalized routine was devised based on three primary components: lung boundary detection, fuzzy c-means (FCM) clustering, and a clinically-derived lung pixel probability map. Boundary detection was used to constrain the lung segmentations. FCM clustering produced grayscale- and neighborhood-based pixel classification probabilities which are weighted by the clinically-derived probability maps to generate a final lung segmentation. Lung centerlines were set along the left-right lung midpoints. Spine centerlines were estimated as a weighted average of body contour, lateral lung contour, and intensity-based centerline estimates. Centerline estimation was tested on 900 clinical AP/PA chest radiographs which included inpatient/outpatient, upright/bedside, men/women, and adult/pediatric images from multiple imaging systems. Our previous implementation further did not account for the presence of medical hardware (pacemakers, wires, implants, staples, stents, etc.) potentially biasing image quality analysis. A hardware detection algorithm was developed using a gradient-based thresholding method. The training and testing paradigm used a set of 48 images from which 1920 51×51 pixel{sup 2} ROIs with and 1920 ROIs without hardware were manually selected. Results: Acceptable lung centerlines were generated in 98.7% of radiographs while spine centerlines were acceptable in 99.1% of radiographs. Following threshold optimization, the hardware detection software yielded average true positive and true negative rates of 92.7% and 96.9%, respectively. Conclusion: Updated segmentation and centerline estimation methods in addition to new gradient-based hardware detection software provide improved data integrity control and error-checking for automated clinical chest image quality characterization across multiple radiography systems.

60 APPLIED LIFE SCIENCES↗

Characterization of the Martinsburg Formation using Computed Tomography and Geophysical Logging Techniques

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) Morgantown site were used to characterize 9 different core sections of Upper Ordovician black shale from the Eastern Panhandle of West Virginia. The samples are representative of the upper Ordovician Martinsburg Formation, a Utica Shale equivalent, which is a carbonaceous black shale in the Appalachian Basin. The primary impetus of this work was to develop a standardized methodology for the rapid and detailed characterization of chemical composition, physical characteristics, and internal micro structure of lithologic samples with the NETL core characterization equipment. Having a standardized methodology combining these innovative techniques allows large, rapidly produced data sets to be available for multiple researchers and allows collaborative studies. The resultant data sets are presented as part of this report as well and can be accessed from NETL's Energy Data eXchange (EDX) online system (https://edx.netl.doe.gov) using the following link: https://edx.netl.doe.gov/dataset/martinsburg-formation-ct-data. All equipment and techniques used were non-destructive, enabling future examinations to be performed on these cores with the additional information gathered through these tests. None of the equipment used was suitable for direct visualization of the shale pore space, though fractures and discontinuities were visible and detectable with all methods tested. High resolution CT imagery with the NETL industrial CT scanner was a powerful and insightful way to examine the details of fractures, discontinuities, minerals, and large crystals within the shale, but was time consuming both in image capture and analysis. As such, only a small percentage of the core was scanned at high resolution. Low resolution CT imagery with the NETL medical CT scanner was performed on the entire core. Qualitative analysis of the medical CT images, coupled with the measurements from the multi-sensor core logger (including x-ray fluorescence, XRF, measurements) were very useful in identifying zones of interest for more detailed analysis and fractured zones. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of all methods used provided a multi-scale analysis of this core and provided both a macro and micro description of the core that is relevant for many subsurface energy related examinations of core that have traditionally been performed at NETL.

47 OTHER INSTRUMENTATION↗

SU-D-201-06: Remote Dosmetric Auditing of VMAT Deliveries for Clinical Trials Using EPID

Purpose: To develop a method for remote dosimetric auditing the delivery of VMAT using EPID which allows for simple, inexpensive and time efficient dosimetric credentialing for clinical trials. Methods: Remote centers are provided with CT datasets and planning guidelines to produce VMAT plans for a head and neck and a post-prostatectomy treatment. Plans are transferred in the planning system to two virtual water equivalent phantoms, one flat and one cylindrical. Cine images are acquired during VMAT delivery to the EPID in air with gantry angle recorded in image headers. Centers also deliver provided calibration plans to enable EPID signal to dose conversion, determination of the central axis, and correction of EPID sag prior to analysis. EPID images and planned doses are sent to the central site. EPID cine images are converted to dose in the virtual phantoms using an established backprojection method (King et al., Med.Phys. 2012) with EPID backscatter correction. Individual arcs (with gantry angles collapsed to zero) are evaluated at 10 cm depth in the flat phantom using 2D gamma, and total doses are evaluated in the cylindrical phantom using 3D gamma. Results are reported for criteria of 3%,3mm, 3%,2mm and 2%,2mm for all points greater than 10% of global maximum. Results: The pilot study for Varian centers has commenced, and three centers have been audited for head and neck plans and two for post-prostatectomy plans to date. The mean pass rate for arc-by-arc 2D analysis at 3%,3mm is 99.5% and for 3D analysis is 95.8%. A method for Elekta linacs using an inclinometer for gantry angle information is under development. Conclusion: Preliminary results for this new method are promising. The method takes advantage of EPID equipment available at most centers and clinically established software to provide a feasible, low cost solution to credentialing centers for clinical trials. Funding has been provided from Calvary Mater Newcastle Department of Radiation Oncology, TROG Cancer Research and the University of Newcastle. Kimberley Legge is the recipient of an Australian Postgraduate Award. Narges Miri is a recipient of a University of Newcastle postgraduate scholarship.

60 APPLIED LIFE SCIENCES↗

Potential of VIIRS Time Series Data for Aiding the USDA Forest Service Early Warning System for Forest Health Threats: A Gypsy Moth Defoliation Case Study

This report details one of three experiments performed during FY 2007 for the NASA RPC (Rapid Prototyping Capability) at Stennis Space Center. This RPC experiment assesses the potential of VIIRS (Visible/Infrared Imager/Radiometer Suite) and MODIS (Moderate Resolution Imaging Spectroradiometer) data for detecting and monitoring forest defoliation from the non-native Eurasian gypsy moth (Lymantria dispar). The intent of the RPC experiment was to assess the degree to which VIIRS data can provide forest disturbance monitoring information as an input to a forest threat EWS (Early Warning System) as compared to the level of information that can be obtained from MODIS data. The USDA Forest Service (USFS) plans to use MODIS products for generating broad-scaled, regional monitoring products as input to an EWS for forest health threat assessment. NASA SSC is helping the USFS to evaluate and integrate currently available satellite remote sensing technologies and data products for the EWS, including the use of MODIS products for regional monitoring of forest disturbance. Gypsy moth defoliation of the mid-Appalachian highland region was selected as a case study. Gypsy moth is one of eight major forest insect threats listed in the Healthy Forest Restoration Act (HFRA) of 2003; the gypsy moth threatens eastern U.S. hardwood forests, which are also a concern highlighted in the HFRA of 2003. This region was selected for the project because extensive gypsy moth defoliation occurred there over multiple years during the MODIS operational period. This RPC experiment is relevant to several nationally important mapping applications, including agricultural efficiency, coastal management, ecological forecasting, disaster management, and carbon management. In this experiment, MODIS data and VIIRS data simulated from MODIS were assessed for their ability to contribute broad, regional geospatial information on gypsy moth defoliation. Landsat and ASTER (Advanced Spaceborne Thermal Emission and Reflection Radiometer) data were used to assess the quality of gypsy moth defoliation mapping products derived from MODIS data and from simulated VIIRS data. The project focused on use of data from MODIS Terra as opposed to MODIS Aqua mainly because only MODIS Terra data was collected during 2000 and 2001-years with comparatively high amounts of gypsy moth defoliation within the study area. The project assessed the quality of VIIRS data simulation products. Hyperion data was employed to assess the quality of MODIS-based VIIRS simulation datasets using image correlation analysis techniques. The ART (Application Research Toolbox) software was used for data simulation. Correlation analysis between MODIS-simulated VIIRS data and Hyperion-simulated VIIRS data for red, NIR (near-infrared), and NDVI (Normalized Difference Vegetation Index) image data products collectively indicate that useful, effective VIIRS simulations can be produced using Hyperion and MODIS data sources. The r(exp 2) for red, NIR, and NDVI products were 0.56, 0.63, and 0.62, respectively, indicating a moderately high correlation between the 2 data sources. Temporal decorrelation from different data acquisition times and image misregistration may have lowered correlation results. The RPC experiment also generated MODIS-based time series data products using the TSPT (Time Series Product Tool) software. Time series of simulated VIIRS NDVI products were produced at approximately 400-meter resolution GSD (Ground Sampling Distance) at nadir for comparison to MODIS NDVI products at either 250- or 500-meter GSD. The project also computed MODIS (MOD02) NDMI (Normalized Difference Moisture Index) products at 500-meter GSD for comparison to NDVI-based products. For each year during 2000-2006, MODIS and VIIRS (simulated from MOD02) time series were computed during the peak gypsy moth defoliation time frame in the study area (approximately June 10 through July 27). Gypsy moth defoliation mapping products from simated VIIRS and MOD02 time series were produced using multiple methods, including image classification and change detection via image differencing. The latter enabled an automated defoliation detection product computed using percent change in maximum NDVI for a peak defoliation period during 2001 compared to maximum NDVI across the entire 2000-2006 time frame. Final gypsy moth defoliation mapping products were assessed for accuracy using randomly sampled locations found on available geospatial reference data (Landsat and ASTER data in conjunction with defoliation map data from the USFS). Extensive gypsy moth defoliation patches were evident on screen displays of multitemporal color composites derived from MODIS data and from simulated VIIRS vegetation index data. Such defoliation was particularly evident for 2001, although widespread denuded forests were also seen for 2000 and 2003. These visualizations were validated using aforementioned reference data. Defoliation patches were visible on displays of MODIS-based NDVI and NDMI data. The viewing of apparent defoliation patches on all of these products necessitated adoption of a specialized temporal data processing method (e.g., maximum NDVI during the peak defoliation time frame). The frequency of cloud cover necessitated this approach. Multitemporal simulated VIIRS and MODIS Terra data both produced effective general classifications of defoliated forest versus other land cover. For 2001, the MOD02-simulated VIIRS 400-meter NDVI classification produced a similar yet slightly lower overall accuracy (87.28 percent with 0.72 Kappa) than the MOD02 250-meter NDVI classification (88.44 percent with 0.75 Kappa). The MOD13 250-meter NDVI classification had a lower overall accuracy (79.13 percent) and a much lower Kappa (0.46). The report discusses accuracy assessment results in much more detail, comparing overall classification and individual class accuracy statistics for simulated VIIRS 400-meter NDVI, MOD02 250-meter NDVI, MOD02-500 meter NDVI, MOD13 250-meter NDVI, and MOD02 500-meter NDMI classifications. Automated defoliation detection products from simulated VIIRS and MOD02 data for 2001 also yielded similar, relatively high overall classification accuracy (85.55 percent for the VIIRS 400-meter NDVI versus 87.28 percent for the MOD02 250-meter NDVI). In contrast, the USFS aerial sketch map of gypsy moth defoliation showed a lower overall classification accuracy at 73.64 percent. The overall classification Kappa values were also similar for the VIIRS (approximately 0.67 Kappa) versus the MOD02 (approximately 0.72 Kappa) automated defoliation detection product, which were much higher than the values exhibited by the USFS sketch map product (overall Kappa of approximately 0.47). The report provides additional details on the accuracy of automated gypsy moth defoliation detection products compared with USFS sketch maps. The results suggest that VIIRS data can be effectively simulated from MODIS data and that VIIRS data will produce gypsy moth defoliation mapping products that are similar to MODIS-based products. The results of the RPC experiment indicate that VIIRS and MODIS data products have good potential for integration into the forest threat EWS. The accuracy assessment was performed only for 2001 because of time constraints and a relative scarcity of cloud-free Landsat and ASTER data for the peak defoliation period of the other years in the 2000-2006 time series. Additional work should be performed to assess the accuracy of gypsy moth defoliation detection products for additional years.The study area (mid-Appalachian highlands) and application (gypsy moth forest defoliation) are not necessarily representative of all forested regions and of all forest threat disturbance agents. Additional work should be performed on other inland and coastal regions as well as for other major forest threats.

Spruce, Joseph P.↗

Analysis research for earth resource information systems - Where do we stand

Discussion of the state of the technology of earth resources information systems relative to future operational implementation. The importance of recognizing the difference between systems with image orientation and systems with numerical orientation is illustrated in an example concerning the effect of noise on multiband multispectral data obtained in an agricultural experiment. It is suggested that the data system hardware portion of the total earth resources information system be designed in terms of a numerical orientation; it is argued, however, that this choise is entirely compatible with image-oriented analysis tasks. Some aspects of interfacing such an advanced technology with an operational user community in such a way as to accommodate the user's need for flexibility and yet provide the services needed on a cost-effective basis are discussed.

Landgrebe, D. A.↗

A study of the Io-associated plasma and neutral sodium cloud

Narrow-band interference filter images were obtained for the Io torus at the S II wavelengths of 6716, 6731 and at the wavelenght of the S III, 9532 spectrum. The purpose of these observations is to study the short term temporal behavior of the torus and to gain a better understanding of the systematic morphology of the torus. From these images, estimates were obtained for the electron and ion densities and ion temperatures as a function of longitude, latitude, radius from Jupiter, and time. From the analysis of images taken in 1983 and 1984, extremely sharp longitudinal variations in plasma density were detected, subcorotational velocities were measures in the torus plasma, the presence of an optical east-west brightness asymmetry was confirmed in the ion emissions, and longitudinal variations were detected in torus ion temperatures.

Pilcher, Carl B.↗

Refine your search to explore more results.