Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IONIZATION CHAMBER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

ANALYSIS OF X-RAY SPECTRA EMITTED FROM THE VENUS ECR ION SOURCE

The Versatile Electron Cyclotron resonance ion source for Nuclear Science (VENUS), located at Lawrence Berkeley National Lab’s 88-inch cyclotron, extracts ion beams from a plasma created by ionizing a gas with energetic electrons. Liquid-helium cooled superconducting coils produce magnetic fi elds that confi ne the plasma and high microwave frequencies heat the electrons enough to allow for successive ionizations of the neutral gas atoms. The combination of strong plasma confi nement and high microwave frequencies results in VENUS’ production of record breaking ion beam currents and high charge state distributions. While in operation, VENUS produces signifi cant quantities of bremsstrahlung, in the form of x-rays, primarily through two processes: 1) electron-ion collisions within the plasma, and 2) electrons are lost from the plasma, collide with the plasma chamber wall, and radiate bremsstrahlung due to their sudden deceleration. The bremsstrahlung deposited into the plasma chamber wall is absorbed by the cold mass used to maintain superconductivity in the magnets and poses an additional heat load on the cryostat. In order for VENUS to reach its maximum operating potential of 10 kW of 28 GHz microwave heating frequency, the heat load posed by the emitted bremsstrahlung must be understood. In addition, studying the bremsstrahlung under various conditions will help further our understanding of the dynamics within the plasma. A code has been written, using the Python programming language, to analyze the recorded bremsstrahlung spectra emitted from the extraction end of VENUS. The code outputs a spectral temperature, which is relatively indicative of the temperature of the hot electrons, and total integrated count number corresponding to each spectra. Bremsstrahlung spectra are analyzed and compared by varying two parameters: 1) the heating frequency, 18 GHz and 28 GHz, and 2) the ratio between the minimum magnetic fi eld and the resonant magnetic fi eld, .44 and .70, at the electron resonant zone.

Benitez, J↗

Design, characterization and installation of the NEXT-100 cathode and electroluminescence regions

NEXT-100 is currently being constructed at the Laboratorio Subterráneo de Canfranc in the Spanish Pyrenees and will search for neutrinoless double beta decay using a high-pressure gaseous time projection chamber (TPC) with 100 kg of xenon. Charge amplification is carried out via electroluminescence (EL) which is the process of accelerating electrons in a high electric field region causing secondary scintillation of the medium proportional to the initial charge. The NEXT-100 EL and cathode regions are made from tensioned hexagonal meshes of 1 m diameter. This paper describes the design, characterization, and installation of these parts for NEXT-100. Simulations of the electric field are performed to model the drift and amplification of ionization electrons produced in the detector under various EL region alignments and rotations. Measurements of the electrostatic breakdown voltage in air characterize performance under high voltage conditions and identify breakdown points. Furthermore, the electrostatic deflection of the mesh is quantified and fit to a first-principles mechanical model. Measurements were performed with both a standalone test EL region and with the NEXT-100 EL region before its installation in the detector. Finally, we describe the parts as installed in NEXT-100, following their deployment in Summer 2023.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time calibration and synchronization of the scintillation light detection system in ICARUS-T600

The ICARUS-T600 Liquid Argon (LAr) Time Projection Chamber (TPC) is presently used as a far detector of the Short Baseline Neutrino (SBN) program at Fermilab (USA) to search for a possible LSND-like sterile neutrino signal at $\Delta m^2 \approx 1 eV^2$ with the Booster Neutrino Beam (BNB). A light detection system, based on 360 large area Photo-Multiplier Tubes (PMTs), has been realized for ICARUS-T600 to detect VUV photons produced after the passage of ionizing particles in LAr. This system is fundamental for the TPC operation, providing an efficient trigger and contributing to the 3D reconstruction of events. Moreover, since the detector is exposed to a huge flux of cosmic rays due to its shallow depths operations, the light detection system allows for the time reconstruction of events, contributing to the identification and to the selection of neutrino interactions within the BNB spill gate. The correct time reconstruction of events requires the precise knowledge of the delay of each PMT channel and a good synchronization of recording electronics, this last based on fast sampling digitizers.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performance and long-term stability of the ICARUS-T600 scintillation light detection system

The ICARUS-T600 Liquid Argon (LAr) Time Projection Chamber (TPC) is presently used as a far detector of the Short Baseline Neutrino (SBN) program at Fermilab (USA) to search for a possible LSND-like sterile neutrino signal at $\Delta m^2 \sim 1 eV^2$ with the Booster Neutrino Beam (BNB). A light detection system, based on 360 large area Photo-Multiplier Tubes (PMTs), has been realized for ICARUS-T600 to detect VUV photons produced after the passage of ionizing particles in LAr. This system is fundamental for the TPC operation, providing an efficient trigger and contributing to the 3D reconstruction of events. Moreover, since the detector is exposed to a huge flux of cosmic rays due to its shallow depths operations, the light detection system allows for the time reconstruction of events, contributing to the identification and to the selection of neutrino interactions within the BNB spill gate. Long-term behavior of PMT gains and timing resolution, demonstrate the robustness and reliability of the ICARUS scintillation light detection system and provide valuable input for the design and operation of future large-scale liquid argon detectors.

Raselli, Gian Luca [INFN, Perugia] (ORCID:00000002↗

Validation and applications of the POLAR code

The Potentials of Large Objects in the Auroral Region (POLAR) code was written to model the charging of large spacecraft by auroral electrons in low polar orbit. It has also proven to be a powerful tool for analysis of active and voltage-plasma interactions. POLAR combines 3-D object definition, direct solution to Poisson's equation, space charge transport, and surface charge computation. Physical effects treated by POLAR include the plasma wake and ram, the geomagnetic field, ionization, sheath and barrier formation, and photo and secondary electron generation and transport. Polar development is complete and it is now available to the aerospace community. The methodology of POLAR is reviewed but concentration is on the applications of POLAR to physical problems and observations with the intent of demonstrating both the code's capabilities, and its limitations. These applications include the Space Shuttle, the Defense Meteorological Satellite Program (DMSP) satellites, sounding rockets, plasma chamber experiments, and things not yet flown.

Cooke, David L.↗

Environmental Testbed Development to Evaluate Power Distribution Materials in Electrified Aircraft (EA)

NASA is pursuing the development of electrified propulsion (EP) technologies to improve air transportation in terms of efficiency, affordability, and sustainability. The power requirements are expected to reach 20 megawatts for large EP commercial airliners. A key challenge is transmission and distribution of the high voltage (20 kilovolts) needed for some EP systems. This is a challenge because the risk of electrical failure in aircraft at high altitude (low pressure) due to corona discharge and other forms of partial discharge increases significantly when voltages exceed 327 V. Corona discharge is a form of partial discharge in which gaseous molecules are ionized by strong electric fields. Corona discharge leads to aging in power transmission lines. Aging is a leading cause of electrical failure in electrical insulation materials. In particular, aging from electrical, vibrational, and thermal stresses decrease the performance life of insulation materials. There are currently no test standards or equipment that can effectively age materials under high altitude, voltage and frequency conditions. This poster proposes a design for a test system including an environmental chamber that can simulate the environment of future EP systems for material and component aging tests.

Materials Test chamber Design↗

Aqueous Photochemistry of Secondary Organic Aerosol of α-Pinene and α-Humulene Oxidized with Ozone, Hydroxyl Radical, and Nitrate Radical

Formation of secondary organic aerosols (SOA) from biogenic volatile organic compounds 13 (BVOC) occurs via O 3 - and OH-initiated reactions during the day and reactions with NO 3 during the 14 night. We explored the effect of these three oxidation conditions on the molecular composition and 15 aqueous photochemistry of model SOA prepared from two common BVOC. A common monoterpene, α- 16 pinene, and sesquiterpene, α-humulene, were used to form SOA in a smog chamber via BVOC + O 3 , 17 BVOC + NO 3 , and BVOC + OH + NOx oxidation. Samples of SOA were collected, extracted in water, 18 and photolyzed in an aqueous solution in order to simulate the photochemical cloud processing of SOA. 19 The extent of change in the molecular level composition of SOA over 4 hours of photolysis (roughly 20 equivalent to 64 hours of photolysis under ambient conditions) was assessed with high-resolution 21 electrospray ionization mass spectrometry. The analysis revealed significant differences in the molecular 22 composition between monoterpene and sesquiterpene SOA formed by the different oxidation pathways. 23 The composition further evolved during photolysis with the most notable change corresponding to the 24 nearly-complete removal of nitrogen-containing organic compounds. Hydrolysis of SOA compounds also 25 occurred in parallel with photolysis. The preferential loss of larger SOA compounds during photolysis 26 and hydrolysis made the SOA compounds more volatile on average. This study suggests that cloud- and 27 fog-processing may under certain conditions lead to a reduction in the SOA loading as opposed to an 28 increase in SOA loading commonly assumed in the literature.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Glow discharge based device for solving mazes

A glow discharge based device for solving mazes has been designed and tested. The device consists of a gas discharge chamber and maze-transformer of radial-azimuth type. It allows changing of the maze pattern in a short period of time (within several minutes). The device has been tested with low pressure air. Once switched on, a glow discharge has been shown to find the shortest way through the maze from the very first attempt, even if there is a section with potential barrier for electrons on the way. It has been found that ionization waves (striations) can be excited in the maze along the length of the plasma channel. The dependancy of discharge voltage on the length of the optimal path through the maze has been measured. A reduction in discharge voltage with one or two potential barriers present has been found and explained. The dependency of the magnitude of discharge ignition voltage on the length of the optimal path through the maze has been measured. The reduction of the ignition voltage with the presence of one or two potential barriers has been observed and explained.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Observables for recoil identification in high-definition Gas Time Projection Chambers

Directional detection of nuclear recoils is broadly desirable in nuclear and particle physics. At low recoil energies, this capability may be used to confirm the cosmological origin of a dark matter signal, to penetrate the so-called neutrino floor, or to distinguish between different neutrino sources. Gas Time Projection Chambers (TPCs) can enable directional recoil detection if the readout granularity is sufficiently high, as is the case when micro-pattern gaseous detectors (MPGDs) are utilized. A key challenge in such detectors is identifying and rejecting background electron recoil events caused by gamma rays from radioactive contaminants in the detector materials and the environment. We define new observables that can distinguish electron and nuclear recoils, even at keV-scale energies, based on the simulated ionization's topology. Here we perform a simulation study that shows these observables outperform the traditionally used discriminant, dE/dx, by up to three orders of magnitude. Furthermore, these new observables work well even at ionization energies well below 10keV and remain robust even in the regime where directionality fails.

79 ASTRONOMY AND ASTROPHYSICS↗

Experiment and theoretical study of the propagation of high power microwave pulse in air breakdown environment

In the study of the propagation of high power microwave pulse, one of the main concerns is how to minimize the energy loss of the pulse before reaching the destination. In the very high power region, one has to prevent the cutoff reflection caused by the excessive ionization in the background air. A frequency auto-conversion process which can lead to reflectionless propagation of powerful EM pulses in self-generated plasmas is studied. The theory shows that under the proper conditions the carrier frequency, omega, of the pulse will indeed shift upward with the growth of plasma frequency, omega(sub pe). Thus, the plasma during breakdown will always remain transparent to the pulse (i.e., omega greater than omega(sub pe)). A chamber experiment to demonstrate the frequency auto-conversion during the pulse propagation through the self-generated plasma is then conducted in a chamber. The detected frequency shift is compared with the theoretical result calculated y using the measured electron density distribution along the propagation path of the pulse. Good agreement between the theory and the experiment results is obtained.

Kuo, S. P.↗

Remeasurement of the 239 Pu(n,f)/ 235 U(n,f) Cross-Section Ratio with the NIFFTE fission Time Projection Chamber Using Vapor-deposited Targets

The NIFFTE fission Time Projection Chamber (fissionTPC) has been used to measure the 239 Pu(n,f)/ 235 U(n,f) cross-section ratio for neutron-induced fission in the range of 0.1–100 MeV, with high precision. A white neutron source was provided by the Los Alamos Neutron Science Center, where the experiment was conducted as a remeasurement to evaluate a roughly 2% discrepancy of the previous fissionTPC results with ENDF/B-VIII.0. Further, a detailed accounting of measurement uncertainties was performed, based on the fissionTPC's novel ability to provide three-dimensional reconstruction of fission-fragment ionization profiles. Current results obtained using a vapor-deposited, highly uniform 239 Pu target, in comparison to the measurement published in 2021, where a 239 Pu electroplated target was used, are presented and discussed. The remeasurement presented here is in agreement with the previous fissionTPC result within measurement uncertainties.

235U↗

Micro cavity fission chamber radiation detection system

A radiation detector to monitor the neutron flux of a nuclear reactor or other high-radiation environment, that can withstand the high temperatures and radiation fields of such environment, is provided. A small dielectric substrate with a low neutron-activation cross section is provided. The substrate is coated with a neutron conversion material, such as uranium oxide or thorium oxide. One or more substrates form a micro-sized detection cavity that is filled with a detection gas. A voltage is provided across anode and cathode wires in the detection cavity. A neutron absorbed in the conversion material may release reaction products into the gas, causing ionization of the gas which then produces a current or voltage signal. The small detector volume minimizes energy deposition into the detection gas by competing particles such as gamma rays, fast electrons, and beta particles, and therefore minimizes false counts while retaining large signals from neutron interactions.

McGregor, Douglas S.↗

Extending the dynamic range of electronics in a Time Projection Chamber

When Time Projection Chambers (TPCs) are used in low to intermediate heavy ion collisions, the mass and momentum range of the emitted particles cover a wide range in energy losses. Many TPC readout electronics currently only have a single gain output with a fixed dynamic range. In a recent set of experiments using the SAMURAI Pion-Reconstruction and Ion-Tracker (StrRIT) TPC, it was important to simultaneously measure relativistic pions and heavy ion tracks from the same collisions. As the ionization from a track's energy loss is collected and multiplied by the anode wires, a distribution of image charges is induced on the TPC read-out pads. If the avalanche on a wire is large enough, the charge collected by pads directly underneath will saturate the readout electronics; pads farther away in the distribution will not be saturated. Using these unsaturated pads and the known pad distribution function, we can estimate the charge on saturated pads, increasing the dynamic range by a factor of 5.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Proton Transfer Time-of-Flight Mass Spectrometer

The Proton Transfer Reaction Mass Spectrometer (PTRMS) measures gas-phase compounds in ambient air and headspace samples before using chemical ionization to produce positively charged molecules, which are detected with a time-of-flight (TOF) mass spectrometer. This ionization method uses a gentle proton transfer reaction method between the molecule of interest and protonated water, or hydronium ion (H 3 O + ), to produce limited fragmentation of the parent molecule. The ions produced are primarily positively charged with the mass of the parent ion, plus an additional proton. Ion concentration is determined by adding the number of ions counted at the molecular ion’s mass-to-charge ratio to the number of air molecules in the reaction chamber, which can be identified according to the pressure levels in the reaction chamber. The PTRMS allows many volatile organic compounds in ambient air to be detected at levels from 10–100 parts per trillion by volume (pptv). The response time is 1 to 10 seconds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microinhomogeneities in Semi-Insulating Cd(Zn)Te

Here, we investigated the temperature dependences (TDs) in the range of 290-423 K for the Hall constant R H and the Hall carrier mobility μn (σ R H ) in semi-insulating Cd 0.9 Zn 0.1 Te:In (CZT) crystals. As-grown, CZT material has nonequilibrium distributions of native and impurity-related defects. Thus, before taking any measurements, the samples were kept inside the test chamber in the dark at 423 K to reach an equilibrium state at T <; 423 K. For all the tested samples, the R H TD could be described by two activation energies. At the transitional point, the TD of the carrier mobility also changes from “normal” at high temperatures to “exponential” at low temperatures. The latter is a result of the collective effect of drift barriers due to microinhomogeneity. Therefore, only the high-temperature activation energies can be assigned to the ionization energies of the compensated deep donors (ε D ). For different samples, the values for ε D 0 (at absolute zero) were found to be in the range of 0.50-0.78 eV, and the degree of donor compensation [D + ]/[D] is between 0.3 and 0.98. The low-temperature region, where there are strong effects of crystal microinhomogeneities, cannot be used to characterize the ionization energy of donors. Therefore, we describe the activation energy as ε 1 = ε D - αε b , where ε b is the drift barrier height found from the TD of the carrier mobility and α takes a value close to unity. Values of ε b for our studied samples lie within (0.05-0.35) eV.

36 MATERIALS SCIENCE↗

Reaching High-Yield Fusion with a Slow Plasma Liner Compressing a Magnetized Target

Dynamics of the compression of a magnetized plasma target by a heavy liner made of partially ionized high high-Z material is discussed. A 'soft-landing' (shockless) mode of the liner deceleration is analyzed. Conclusion is drawn that such mode is possible for the liners whose thickness at the time of the first contact with the target is smaller than, roughly, 10% of the initial (un-compressed) target radius. A combination of the plasma liner with one or two glide cones allows for a direct access to the area near the center of the reactor chamber. One can then generate plasma target inside the plasma liner at the optimum time. The other advantage of the glide cones is that they can be used to deliver additional fuel to the center of the target near the point of a maximum compression and thereby increase the fusion yield.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Measurement of the Attenuation of Drifting Electrons in the MicroBooNE LArTPC

MicroBooNE, an 85-ton active mass liquid-argon time-projection chamber (LArTPC) detector located on the Fermilab’s Booster Neutrino Beamline (BNB), is designed to both probe neutrino physics phenomena and further develop the LArTPC detector technology. MicroBooNE, the largest currently operating LArTPC detector in the world, began collecting data in fall 2015. The exceptional imaging capabilities of LArTPCs allow unprecedented study of neutrino interactions. A fundamental requirement for the performance of such detectors is to maintain electronegative contaminants such as oxygen and water at extremely low concentrations, which otherwise can capture the ionization electrons. This note presents a first measurement of the electron attenuation as a function of drift time, using cosmic ray muon data collected by MicroBooNE. The observed electron attenuation indicates that during stable purity period, the lowest electron drift-lifetime observed is 18.0 ms which corresponds to a charge loss of 12% over the full drift distance at an electric field of 0.273 kV/cm and an O 2 equivalent contamination of 17 ppt. This is an indication that the argon purification and recirculation system of MicroBooNE is performing successfully.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Desorbed Gas Molecular Ionization Mechanism for Arcing Onset in Solar Arrays Immersed in a Low-Density Plasma

Previous experimental studies have hypothesized that the onset of Solar Array Arc (SAA) initiation in low-density space plasmas is caused by a desorbed gas molecular ionization mechanism. Indeed past investigations performed at the NASA Glenn Plasma Interaction Facility tend to not only support the desorbed gas molecular ionization mechanism, but have gone as far as identifying the crucial molecular species that must be present for molecular ion dominated process to occur. When electrical breakdown occurs at a triple junction site on a solar array panel, a quasi-neutral plasma cloud is ejected. Assuming the main component of the expelled plasma cloud by weight is due to water vapor, the fastest process available is due to HO molecules and OH(+) ions, or more succinctly, dissociative molecular-ion dominated recombination processes: H2O(+) + e(-) yields H* + OH*. Recently published spectroscopic observations of solar array arc spectra in ground tests have revealed the well-known molecular OH band (302 to 309nm), as well as the molecular SiH band (387nm peak), and the molecular CH band (432nm peak). Note that the OH band is observed in emission arcs where water vapor is present. Strong atomic lines were also observed for H(sub beta) at 486nm and H(sub alpha) at 656.3nm in prior ground testing. Independent supporting evidence of desorbed gas molecular ionization mechanisms also come from measurements of arc current pulse widths at different capacitances. We will revisit an earlier first order approximation demonstrating the dependence of arc current pulse widths on the square root of the capacitance. The simple arc current pulse width model will be then be used to estimate the temperature of the arc plasma (currently believed to be somewhere in the range of 3 to 5 eV). The current paper then seeks to extend the outlined work by including numerous vacuum chamber measurements obtained with a quadrupole mass spectrometer. A small solar array was mounted inside the vacuum chamber. A plasma source, also mounted inside the vacuum chamber, is used to simulate a low-density plasma environment. The solar array is then biased to a high negative potential and allowed to arc while a mass spectrometer is used to record the partial pressure of H2O and to track other significant changes in mass (1 to 150) AMU.

Galofaro, J.↗

Refine your search to explore more results.