Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IMPLANTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

A preliminary evaluation of immune stimulation following exposure to metal particles and ions using the mouse popliteal lymph node assay

The objective of this preliminary study was to evaluate the threshold for immune stimulation in mice following local exposure to metal particles and ions representative of normal-functioning cobalt-chromium (CoCr) metal-on-metal (MoM) hip implants. The popliteal lymph node assay (PLNA) was used in this study to assess immune responses in BALB/c mice following treatment with chromium-oxide (Cr{sub 2}O{sub 3}) particles, metal salts (CoCl{sub 2}, CrCl{sub 3} and NiCl{sub 2}), or Cr{sub 2}O{sub 3} particles together with metal salts using single-dose exposures representing approximately 10 days (0.000114 mg), 19 years (0.0800 mg), and 40 years (0.171 mg) of normal implant wear. The immune response elicited following treatment with Cr{sub 2}O{sub 3} particles together with metal salts was also assessed at four additional doses equivalent to approximately 1.5 months (0.0005 mg), 0.6 years (0.0025 mg), 2.3 years (0.01 mg), and 9.3 years (0.04 mg) of normal implant wear. Mice were injected subcutaneously (50 μL) into the right hind foot with the test article, or with the relevant vehicle control. The proliferative response of the draining lymph node cells (LNC) was measured four days after treatment, and stimulation indices (SI) were derived relative to vehicle controls. The PLNA was negative (SI < 3) for all Cr{sub 2}O{sub 3} particle doses, and was also negative at the lowest dose of the metal salt mixture, and the lowest four doses of the Cr{sub 2}O{sub 3} particles with metal salt mixture. The PLNA was positive (SI > 3) at the highest two doses of the metal salt mixture and the highest three doses of the Cr{sub 2}O{sub 3} particles with the metal salt mixture. The provisional NOAEL and LOAEL values identified in this study for immune activation corresponds to Co and Cr concentrations in the synovial fluid approximately 500 and 2000 times higher than that reported for normal-functioning MoM hip implants, respectively. Overall, these results indicate that normal wear conditions are unlikely to result in immune stimulation in individuals not previously sensitized to metals. - Highlights: • Immune responses in mice were assessed following treatment with Cr2O3 particles with metal salts. • The PLNA was negative (SI < 3) for all Cr2O3 particle doses. • A LOAEL for immune activation was identified at 0.04 mg of metal particles with metal salts. • A NOAEL for immune activation was identified at 0.01 mg of metal particles with metal salts.

60 APPLIED LIFE SCIENCES↗

Surface Mechanoengineering of a Zr-based Bulk Metallic Glass via Ar-Nanobubble Doping to Probe Cell Sensitivity to Rigid Materials

In this paper, a new materials platform, utilizing the amorphous microstructure of bulk metallic glasses (BMGs) and the versatility of ion implantation, was developed for the fundamental investigation of cell responses to substrate-rigidity variations in the gigapascal modulus range, which was previously unattainable with polymeric materials. The surface rigidity of a Zr-Al- Ni-Cu-Y BMG was modulated with low-energy Ar-ion implantation owing to the impartment of Ar nanobubbles into the amorphous matrix. Surface softening was achieved due to the formation of nanobubble-doped transitional zones in the Zrbased BMG substrate. Bone-forming cell studies on this newly designed platform demonstrated that mechanical cues, accompanied with the potential effects of other surface properties (i.e. roughness, morphology, and chemistry), contributed to modulating cell behaviors. Cell adhesion and actin filaments were found to be less established on less stiff surfaces, especially on the surface with an elastic modulus of 51 GPa. Cell growth appeared to be affected by surface mechanical properties. A lower stiffness was generally related to a higher growth rate. Findings in this study broadened our fundamental understanding concerning the mechanosensing of bone cells on stiff substrates. It also suggests that surface mechano-engineering of metallic materials could be a potential strategy to promote osseointegration of such materials for bone-implant applications. Further investigations are proposed to fine tune the ion implantation variables in order to further distinguish the surface-mechanical effect on bone-forming cell activities from the contributions of other surface properties.

36 MATERIALS SCIENCE↗

Modeling of plasma-target interaction during reactive magnetron sputtering of TiN

The nitrogen incorporation at the target during reactive magnetron sputtering of TiN is described by a simple stationary global model of the magnetron plasma, in combination with an analytical two-layer stationary surface model or dynamic collisional computer simulation (TRIDYN) of the surface processes. Results are shown for different nitrogen gas additions in Ar/N{sub 2} and Xe/N{sub 2} gas mixtures at a total pressure of 0.3 Pa and a magnetron current of 0.3 A. The nitrogen incorporation predicted by the analytical model is significantly less than obtained from computer simulation. The computer simulation yields nitrogen depth profiles which extend to about 2.5 nm, exhibiting a quasirectangular shape in case of stoichiometric saturation with an integrated nitrogen areal density of {approx}1.25x10{sup 16} N/cm{sup 2}. The stationary-state nitrogen incorporation results from the balance of surface adsorption in connection with recoil implantation, direct ion implantation, and resputtering. The most relevant species are nitrogen gas molecules for adsorption, molecular nitrogen ions for implantation, and inert gas ions for recoil implantation and sputtering. The model results are in good agreement with experiment provided that nonzero sticking of nitrogen gas molecules is assumed on the unsaturated surface. The analytical surface model is preferable, which favors the picture of a continuous transition to bulk and surface saturation rather than discrete local saturation which is inherent in TRIDYN. Also the relative nitrogen incorporation for Xe/N{sub 2} versus Ar/N{sub 2} gas mixtures is well described.

36 MATERIALS SCIENCE↗

Comprehensive model of damage accumulation in silicon

Ion implantation induced damage accumulation is crucial to the simulation of silicon processing. We present a physically based damage accumulation model, implemented in a nonlattice atomistic kinetic Monte Carlo simulator, that can simulate a diverse range of interesting experimental observations. The model is able to reproduce the ion-mass dependent silicon amorphous-crystalline transition temperature of a range of ions from C to Xe, the amorphous layer thickness for a range of amorphizing implants, the superlinear increase in damage accumulation with dose, and the two-layered damage distribution observed along the path of a high-energy ion. In addition, this model is able to distinguish between dynamic annealing and post-cryogenic implantation annealing, whereby dynamic annealing is more effective in removing damage than post-cryogenic implantation annealing at the same temperature.

36 MATERIALS SCIENCE↗

SIMS/ARXPS - A New Technique of Retained Dopant Dose and Profile Measurement of Low Energy Doping Processes

A newly-developed surface analysis technique, which combines Secondary Ion Mass Spectrometry (SIMS) with Angle-Resolved X-ray Photoelectron Spectroscopy (ARXPS), was used to achieve more accurate results of the retained impurity doses and profiles for ultra-low energy implants, including conventional beam-line implant and plasma immersion ion implantation (PIII). Using this method, it has been found that the B{sub 2}H{sub 6}(Diborane) PIII demonstrates thicker native oxide and much more B dose loss during RTP and surface clean treatments than conventional beam-line ion implantation, due to the higher surface B concentration. In order to match the electrical parameters of the device, PIII must consider higher nominal dose to compensate the B loss.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Formation of Ultra-Shallow Junctions by Advanced Plasma Doping Techniques

The fabrication of advanced CMOS devices calls for production worthy doping solutions to address requirements for increasingly shallow and abrupt junctions, while maintaining high dopant activation to meet series resistance requirements. Plasma Doping (PLAD), which has already been adopted in high volume manufacturing in the ultra high dose, low energy regime for advanced DRAM technology nodes, is now being investigated for source drain extension (SDE) implants, where precise and repeatable dopant placement is critical for maintaining control over device parameters. In this article, we investigate the process performance of SDE implants carried out in a VIISta registered PLAD system using p- type dopant precursors. Key metrics, such as junction depth, profile abruptness and sheet resistance are reported for as-implanted junctions, as well as samples processed with low thermal budget anneal techniques. Device performance data demonstrating the feasibility of the approach are presented. The advanced control features in the PLAD system are critical in enabling the process performance required for SDE implants.

36 MATERIALS SCIENCE↗

Local Resistance Profiling of Ultra Shallow Junction Annealed with Combination of Spike Lamp and Laser Annealing Processes using Scanning Spreading Resistance Microscope

Local resistance profiles of ultra shallow boron and arsenic implanted into silicon with energies of 2.0 and 4.0 keV and doses of 2.0x10{sup 15} and 1.0x10{sup 15} ions/cm{sup 2} activated by a combination of conventional spike lamp and laser annealing processes were measured by scanning spreading resistance microscope (SSRM) with a depth resolution of less than 10 nm. The lowest local resistance at the low resistance region in 2.0 keV boron implanted silicon with 1050 deg. C spike lamp annealing followed by 0.35 kW/mm{sup 2} laser annealing was half of that without laser annealing. The lowest local resistance at the low resistance region in the arsenic implanted silicon activated by 1050 deg. C spike lamp annealing followed by 0.39 kW/mm{sup 2} laser annealing was 74% lower than that followed by 0.36 kW/mm{sup 2} laser annealing. The lowest local resistances at the low resistance regions in the arsenic implanted silicon with 0.36 and 0.39 kW/mm{sup 2} laser annealing followed by 1050 deg. C spike lamp annealing were 41 and 33% lower than those with spike lamp annealing followed by laser annealing. Laser annealing followed by spike lamp annealing could suppress the diffusion of the impurities and was suitable for making the ultra shallow and low resistance regions.

36 MATERIALS SCIENCE↗

Surface Characteristics of Titanium during ECM Process for Biomedical Applications

Electrochemical machining is described as the controlled removal of metal by anodic dissolution of the workpiece in electrolyte cell. Titanium is extensively used in aerospace, defence, biomedical applications. The human response to implanted titanium parts strongly related to the implant surface conditions. The aim of this paper is to present experimental investigation on electrochemically machined surface characteristics acquired on titanium, utilizing developed cross flow electrolyte system. It is observed that applied voltage and electrolyte flow rate are the some of the persuading parameter to attain desired surface characteristics on machined surface. Attempt has made to develop surface along with self-generated oxide layer, which facilitates in improving the corrosion and chemical resistance of titanium implant in biomedical application. The surface roughness of oxide layered machined surface obtained within 2.4 {mu}m to 2.93 {mu}m, which is within acceptable value for functional attachment between bone and implant.

36 MATERIALS SCIENCE↗

Defect mitigation by ion induced amorphousization and solid-phase epitaxy

Ion implantation is a common technique in the semiconductor industry used to modify the electrical properties of materials, usually silicon. Some dopant ions are sufficiently light, such as boron, that they do not create a continuous amorphous layer in silicon over the range of the ions. In the presence of such a layer, most of the ioninduced damage can be removed by solid-phase epitaxy growth (SPEG), which results in recrystallization of the amorphous damage. However, end-of-range defects at the amorphous-crystal interface give rise to threading dislocations during SPEG that degrade the quality of the recrytallized Si. We have studied the end of range defects in silicon with three different implantations. The first was with 80 keV {sup 30}Si with a dose of 3 Multiplication-Sign 10{sup 15} Si/cm{sup 2}, and the second was with 100 keV {sup 72}Ge at a dose of 1 Multiplication-Sign 10{sup 15} Ge/cm{sup 2}, and the third was a double implant of 100 keV {sup 72}Ge at a dose of 1 Multiplication-Sign 10{sup 15} Ge/cm{sup 2} followed by 340 keV {sup 28}Si at a dose of 3 Multiplication-Sign 10{sup 14} Si/cm{sup 2}. SPEG was done at 650 Degree-Sign C to recrystalize the implanted samples, and the end of range defects were studied using channeled Rutherford Backscattering Spectrometry (RBS-c). The effects of photon-assisted hydrogenation on amorphization and recrystallization were also studied.

36 MATERIALS SCIENCE↗

Controlled synthesis of buried delta-layers of Ag nanocrystals for near-field plasmonic effects on free surfaces

We report on the shallow synthesis by low energy ion implantation of delta-layers of Ag nanocrystals in SiO{sub 2} at few nanometers under its free surface. Transmission electron microscopy observations, ballistic simulations, and reflectance measurements are coupled to define the conditions for which the synthesis is fully controlled and when, on the contrary, this control is lost. We show that low dose implantation leads to the formation of a well-defined single plane of nanocrystals, while for larger doses, sputtering and diffusion effects limit the control of the size, position, and volume amount of these nanocrystals. This paper provides the experimental evidence of the incorporated dose saturation predicted in the literature when implanting metal ions at high doses in glass matrices. Its consequences on the particle population and the plasmonic optical response of the composite layers are carefully analyzed. We show here that this saturation phenomenon is underestimated in standard simulation predictions due to diffusion of metal atoms towards the surface and nanocrystal nucleation during the implantation process.

36 MATERIALS SCIENCE↗

Creation of deep blue light emitting nitrogen-vacancy center in nanosized diamond

This paper reports on the formation of complex defect centers related to the N3 center in nanosized diamond by employing plasma immersion and focused ion beam implantation methods. He{sup +} ion implantation into nanosized diamond “layer” was performed with the aim of creating carbon atom vacancies in the diamond structure, followed by the introduction of molecular N{sub 2}{sup +} ion and heat treatment in vacuum at 750 °C to initiate vacancy diffusion. To decrease the sp{sup 2} carbon content of nanosized diamond formed during the implantation processes, a further heat treatment at 450 °C in flowing air atmosphere was used. The modification of the bonding properties after each step of defect creation was monitored by Raman scattering measurements. The fluorescence measurements of implanted and annealed nanosized diamond showed the appearance of an intensive and narrow emission band with fine structures at 2.98 eV, 2.83 eV, and 2.71 eV photon energies.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Tuning the ferromagnetic-antiferromagnetic interfaces of granular Co-CoO exchange bias systems by annealing

The low-temperature magnetic behavior of granular Co-CoO exchange bias systems, prepared by oxygen ion implantation in Co thin films and subsequent annealing, is addressed. The thermal activation effects lead to an O migration which results in virtually pure Co areas embedded in a structurally relaxed and nearly stoichiometric CoO phase. This yields decreased training and exchange bias shifts, while the blocking temperature significantly increases, coming close to the Néel temperature of bulk CoO for samples implanted to a fluence above 1 × 10{sup 17} ions/cm{sup 2} (15% O). The dependence of the exchange bias shift on the pristine O-implanted content is analogous to that of the antiferromagnetic thickness in most ferromagnetic/antiferromagnetic systems (i.e., an increase in the exchange bias shift up to a maximum followed by a decrease until a steady state is reached), suggesting that, after annealing, the enriched Co areas might be rather similar in size for samples implanted above 1 × 10{sup 17} ions/cm{sup 2}, whereas the corresponding CoO counterparts become enlarged with pristine O content (i.e., effect of the antiferromagnet size). This study demonstrates that the magnetic properties of granular Co-CoO systems can be tailored by controllably modifying the local microstructure through annealing treatments.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Atomistic simulation of damage accumulation and amorphization in Ge

Damage accumulation and amorphization mechanisms by means of ion implantation in Ge are studied using Kinetic Monte Carlo and Binary Collision Approximation techniques. Such mechanisms are investigated through different stages of damage accumulation taking place in the implantation process: from point defect generation and cluster formation up to full amorphization of Ge layers. We propose a damage concentration amorphization threshold for Ge of ∼1.3 × 10{sup 22} cm{sup −3} which is independent on the implantation conditions. Recombination energy barriers depending on amorphous pocket sizes are provided. This leads to an explanation of the reported distinct behavior of the damage generated by different ions. We have also observed that the dissolution of clusters plays an important role for relatively high temperatures and fluences. The model is able to explain and predict different damage generation regimes, amount of generated damage, and extension of amorphous layers in Ge for different ions and implantation conditions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ion beam synthesis of ZrC{sub x}O{sub y} nanoparticles in cubic zirconia

{110}-oriented yttria-stabilized zirconia single crystals have been implanted with low-energy C ions in an axial direction, at room temperature and at 550 °C. Room temperature ion implantation generated a damage layer that contains the expected dislocation loop clusters. Strikingly, the high temperature implantation produced zirconium oxycarbide nanoparticles (ZrC{sub x}O{sub y}) at a shallow depth in the yttria-stabilized cubic zirconia crystal, with a diameter in the range of 4–10 nm. Moreover, in the high concentration region of implanted C ions, between 100 and 150 nm below the surface, a number of large precipitates, up to 20 nm, were observed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Helium solubility in SON68 nuclear waste glass

Helium behavior in a sodium borosilicate glass (SON68) dedicated to the immobilization of high-level nuclear waste is examined. Two experimental approaches on nonradioactive glass specimens are implemented: pressurized helium infusion experiments and {sup 3}He ion implantation experiments. The temperature variation of helium solubility in SON68 glass was determined and analyzed with the harmonic oscillator model to determine values of the energy of interaction E(0) at the host sites (about -4000 J/mol), the vibration frequency (about 1.7 x 10{sup 11} s{sup -1}), and the density of solubility sites (2.2 x 10{sup 21} sites cm{sup -3}). The implantation experiments show that a non diffusive transport phenomenon (i.e., athermal diffusion) is involved in the material when the helium concentration exceeds 2.3 x 10{sup 21} He cm{sup -3}, and thus probably as soon as it exceeds the density of solubility sites accessible to helium in the glass. We propose that this transport mechanism could be associated with the relaxation of the stress gradient induced by the implanted helium profile, which is favored by the glass damage. Microstructural characterization by TEM and ESEM of glass specimens implanted with high helium concentrations showed a homogeneous microstructure free of bubbles, pores, or cracking at a scale of 10 nm. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Incorporation of hydrogen in CuInSe{sub 2}: Improvements of the structure

CuInSe{sub 2} single crystals were ion implanted with a dose of 3 x 10{sup 16} cm{sup -2} by 2.5 keV H{sup +} at 150 and 250 deg. C Before and after the implantation the crystals were analyzed by Rutherford backscattering/channeling (RBS/C) along the <112> axis using 2 MeV He{sup +}. The RBS/C spectra indicate that the implantation at 150 deg. C introduces a layer of radiation damage, whereas after the implantation at 250 deg. C no structural deterioration of the lattice can be seen. Quite the contrary, the RBS/C spectra reveal a considerable decrease in the dechanneling parameters suggesting improvements in the lattice structural quality attributed to the incorporation of hydrogen.

36 MATERIALS SCIENCE↗

Reconstruction of brachytherapy seed positions and orientations from cone-beam CT x-ray projections via a novel iterative forward projection matching method

Purpose: To generalize and experimentally validate a novel algorithm for reconstructing the 3D pose (position and orientation) of implanted brachytherapy seeds from a set of a few measured 2D cone-beam CT (CBCT) x-ray projections. Methods: The iterative forward projection matching (IFPM) algorithm was generalized to reconstruct the 3D pose, as well as the centroid, of brachytherapy seeds from three to ten measured 2D projections. The gIFPM algorithm finds the set of seed poses that minimizes the sum-of-squared-difference of the pixel-by-pixel intensities between computed and measured autosegmented radiographic projections of the implant. Numerical simulations of clinically realistic brachytherapy seed configurations were performed to demonstrate the proof of principle. An in-house machined brachytherapy phantom, which supports precise specification of seed position and orientation at known values for simulated implant geometries, was used to experimentally validate this algorithm. The phantom was scanned on an ACUITY CBCT digital simulator over a full 660 sinogram projections. Three to ten x-ray images were selected from the full set of CBCT sinogram projections and postprocessed to create binary seed-only images. Results: In the numerical simulations, seed reconstruction position and orientation errors were approximately 0.6 mm and 5 deg., respectively. The physical phantom measurements demonstrated an absolute positional accuracy of (0.78{+-}0.57) mm or less. The {theta} and {phi} angle errors were found to be (5.7{+-}4.9) deg. and (6.0{+-}4.1) deg., respectively, or less when using three projections; with six projections, results were slightly better. The mean registration error was better than 1 mm/6 deg. compared to the measured seed projections. Each test trial converged in 10-20 iterations with computation time of 12-18 min/iteration on a 1 GHz processor. Conclusions: This work describes a novel, accurate, and completely automatic method for reconstructing seed orientations, as well as centroids, from a small number of radiographic projections, in support of intraoperative planning and adaptive replanning. Unlike standard back-projection methods, gIFPM avoids the need to match corresponding seed images on the projections. This algorithm also successfully reconstructs overlapping clustered and highly migrated seeds in the implant. The accuracy of better than 1 mm and 6 deg. demonstrates that gIFPM has the potential to support 2D Task Group 43 calculations in clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Monte Carlo investigation of I-125 interseed attenuation for standard and thinner seeds in prostate brachytherapy with phantom validation using a MOSFET

Purpose: In permanent seed implant prostate brachytherapy the actual dose delivered to the patient may be less than that calculated by TG-43U1 due to interseed attenuation (ISA) and differences between prostate tissue composition and water. In this study the magnitude of the ISA effect is assessed in a phantom and in clinical prostate postimplant cases. Results are compared for seed models 6711 and 9011 with 0.8 and 0.5 mm diameters, respectively. Methods: A polymethyl methacrylate (PMMA) phantom was designed to perform ISA measurements in a simple eight-seed arrangement and at the center of an implant of 36 seeds. Monte Carlo (MC) simulation and experimental measurements using a MOSFET dosimeter were used to measure dose rate and the ISA effect. MC simulations of 15 CT-based postimplant prostate treatment plans were performed to compare the clinical impact of ISA on dose to prostate, urethra, rectum, and the volume enclosed by the 100% isodose, for 6711 and 9011 seed models. Results: In the phantom, ISA reduced the dose rate at the MOSFET position by 8.6%-18.3% (6711) and 7.8%-16.7% (9011) depending on the measurement configuration. MOSFET measured dose rates agreed with MC simulation predictions within the MOSFET measurement uncertainty, which ranged from 5.5% to 7.2% depending on the measurement configuration (k= 1, for the mean of four measurements). For 15 clinical implants, the mean ISA effect for 6711 was to reduce prostate D90 by 4.2 Gy (3%), prostate V100 by 0.5 cc (1.4%), urethra D10 by 11.3 Gy (4.4%), rectal D2cc by 5.5 Gy (4.6%), and the 100% isodose volume by 2.3 cc. For the 9011 seed the mean ISA effect reduced prostate D90 by 2.2 Gy (1.6%), prostate V100 by 0.3 cc (0.7%), urethra D10 by 8.0 Gy (3.2%), rectal D2cc by 3.1 Gy (2.7%), and the 100% isodose volume by 1.2 cc. Differences between the MC simulation and TG-43U1 consensus data for the 6711 seed model had a similar impact, reducing mean prostate D90 by 6 Gy (4.2%) and V100 by 0.6 cc (1.8%). Conclusions: ISA causes the delivered dose in prostate seed implant brachytherapy to be lower than the dose calculated by TG-43U1. MC simulation of phantom seed arrangements show that dose at a point can be reduced by up to 18% and this has been validated using a MOSFET dosimeter. Clinical simulations show that ISA reduces DVH parameter values, but the reduction is less for thinner seeds.

60 APPLIED LIFE SCIENCES↗

Refine your search to explore more results.