Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Hydro”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Long-term thermal effects on injectivity evolution during CO 2 storage

Carbon dioxide (CO 2 ) is likely to reach the bottom of injection wells at a colder temperature than that of the storage formation, causing cooling of the rock. This cooling, together with overpressure, tends to open up fractures, which may enhance injectivity. Here, we investigate cooling effects on injectivity enhancement by modeling the In Salah CO 2 storage site and a theoretical, long-term injection case. We use stress-dependent permeability functions that predict an increase in permeability as the effective stress acting normal to fractures decreases. Normal effective stress can decrease either due to overpressure or cooling. We calibrate our In Salah model, which includes a fracture zone perpendicular to the well, obtaining a good fitting with the injection pressure measured at KB-502 and the rapid CO 2 breakthrough that occurred at the observation well KB-5 located 2 km away from the injection well. CO 2 preferentially advances through the fracture zone, which becomes two orders of magnitude more permeable than the rest of the reservoir. Nevertheless, the effect of cooling on the long-term injectivity enhancement is limited in pressure dominated storage sites, like at In Salah, because most of the permeability enhancement is due to overpressure. But, thermal effects enhance injectivity in cooling dominated storage sites, which may decrease the injection pressure by 20%, saving a significant amount of compression energy all over the duration of storage projects. Overall, our simulation results show that cooling has the potential to enhance injectivity in fractured reservoirs.

58 GEOSCIENCES↗

Bio-inspired alula-based winglet design for enhanced heat transfer in high temperature fin-and-tube heat exchangers

Fin-and-tube heat exchangers (FTHEs) are widely used for high-temperature flue-gas heat recovery, but their performance is often limited by wake regions and non-uniform fin-surface temperatures. This study proposes and numerically evaluates four bio-inspired longitudinal vortex generator (VG) configurations in a high-temperature FTHE with flue-gas inlet temperature ∼1230 K: double-delta, curved double-delta, alula, and a new curved-alula geometry. The reference fin is not hydraulically plain; it already incorporates leading-edge separation columns and convex protrusions, so the alula-type winglets are assessed as downstream add-ons acting on a strongly disturbed flow. In a second step, perforations (one, two and three circular holes) are introduced into the curved-alula VGs to further tailor the flow field. Three-dimensional simulations with the Shear Stress Transpor (SST) $k - ω$ model, temperature-dependent flue-gas properties and conjugate conduction are carried out for gas-side Reynolds numbers $Re_g ≈ 8.0$ x $10^2 - 3.6$ x $10^3$ (mass flow rates 0.5 – 2.5 g/s), and the designs are compared in terms of surface heat flux, Nusselt number, friction factor and hydrothermal performance factor (HTPF). For this already-promoted fin, the additional downstream winglets provide moderate, incremental hydrothermal gains. At the highest Reynolds number, the best non-perforated design (curved-alula) increases surface heat flux from 1630.9 to 1794.7 kW/m² (∼ 10 % gain) and the Nusselt number from 227.6 to 242.6 (∼ 7 % gain), while the friction factor rises from 0.26 to about 0.30, yielding HTPF values close to unity (∼ 0.9 – 1.0). Introducing circular perforations into the curved-alula winglets acts mainly as a wake-bleeding refinement: the three-hole configuration provides a heat flux of 1824.7 kW/m² and a pressure drop of 127.9 Pa, with HTPF in the range ∼ 1.03 – 1.14 and a small (∼ 1 – 3 %) improvement over the solid curved-alula design. Flow-field analysis shows that the perforated curved-alula VGs shrink tube-wake regions, thin the thermal boundary layer and homogenize the fin-surface temperature (outlet-gas temperature ∼ 510 – 520 K and fin-surface temperature ∼ 420 – 421 K for the three-hole case). An optimal flue-gas mass flow rate of ∼ 1 g/s ($Re_g ≈ 1.5$ x $10^3$) is identified, beyond which additional heat-transfer gains are offset by rapidly increasing pressure losses. Overall, the results highlight that initial fin geometry and VG placement are as important as VG shape: alula-based winglets are expected to yield larger relative gains on simpler flat-fin layouts or when positioned closer to the fin leading edge and tube

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impact of hydrogen SAE J2601 fueling methods on fueling time of light-duty fuel cell electric vehicles

Hydrogen fuel cell electric vehicles (HFCEVs) are zero-emission vehicles (ZEVs) that can provide drivers a similar experience to conventional internal combustion engine vehicles (ICEVs), in terms of fueling time and performance (i.e. power and driving range). The Society of Automotive Engineers (SAE) developed fueling protocol J2601 for light-duty HFCEVs to ensure safe vehicle fills while maximizing fueling performance. This study employs a physical model that simulates and compares the fueling performance of two fueling methods, known as the “lookup table” method and the “MC formula” method, within the SAE J2601 protocol. Both the fueling methods provide fast fueling of HFCEVs within minutes, but the MC formula method takes advantage of active measurement of precooling temperature to dynamically control the fueling process, and thereby provides faster vehicle fills. Here, the MC formula method greatly reduces fueling time compared to the lookup table method at higher ambient temperatures, as well as when the precooling temperature falls on the colder side of the expected temperature window for all station types. Although the SAE J2601 lookup table method is the currently implemented standard for refueling hydrogen fuel cell vehicles, the MC formula method provides significant fueling time advantages in certain conditions; these warrant its implementation in future hydrogen refueling stations for better customer satisfaction with fueling experience of HFCEVs.

13 HYDRO ENERGY↗

Rapid high density cryogenic pressure vessel filling to 345 bar with a liquid hydrogen pump

Cryogenic pressurized hydrogen (H 2 ) vessels promise maximum storage density with potential to enabling practical H 2 vehicles with maximum driving autonomy and minimum cost of ownership. This paper adds a more complete evaluation of the benefits of cryogenic vessel technology by establishing a methodology for evaluating fill density for any initial vessel thermodynamic state. This is accomplished by assessing 24 cryogenic pressure vessel fill experiments with a liquid hydrogen (LH 2 ) pump manufactured by Linde and installed at the Lawrence Livermore National Laboratory (Livermore, CA) campus. The LH 2 piston pump takes LH 2 from the station Dewar at near ambient pressure (3 bar) and very low temperature (24.6 K) and pressurizes it to the vessel pressure in two stages of compression, up to 875 bar, although the rating of the cryogenic vessel used for these experiments limits fill pressure to 345 bar. Experiments spanned initial vessel temperatures from ambient to 22 K, enabling pump testing over a broad range of conditions. Experimental results validate many of the virtues that make LH 2 pumping a promising technology for H 2 dispensing, both for filling cryogenic as well as ambient temperature vessels: high throughput (1.67 kg/min, 100 kg/h), unlimited capacity for back to back refueling, low electricity consumption at the station due to high density of LH 2 minimizing compression work, and highest fill density, up to 80 g/L (estimated) when dispensing cryogenic hydrogen at 700 + bar. Analysis of the experiments shows that fill density can be predicted with reasonable accuracy (±0.7 g/L) by assuming 10 kJ/kg K cryogenic vessel inlet entropy (pump delivery hose outlet entropy). Fill lines are finally generated on a H 2 phase diagram, producing charts that can be used for rapidly determining fill density for any vessel condition at the moment of fill initiation.

08 HYDROGEN↗

The fill density of automotive cryo-compressed hydrogen vessels

Cryo-compressed hydrogen storage promises to deliver highest system storage density leading to fundamental cost and safety advantages. Yet, cryogenic vessels are complex systems, continuously drifting in thermodynamic space depending on use patterns, insulation performance, vessel characteristics, liquid hydrogen pump performance, and para-H 2 to ortho-H 2 conversion. This paper reflects a comprehensive evaluation of all factors affecting cryogenic vessel fill density, in an effort to evaluate system performance vs. operational parameters over a broad range of conditions. The results validate previous experiments and models indicating that cryogenic vessels have maximum fill density of all available storage technologies, and fill density is most sensitive to daily driving distance and insulation performance. It is lastly predicted that para-H 2 to ortho-H 2 conversion will affect most automobiles, increasing fill density by up to 5.3%. In a future world dominated by cryogenic H 2 fueled vehicles, para-H 2 to ortho-H 2 conversion inside the vessel will be the closest contact an average person will have with quantum mechanics outside of consumer electronics.

08 HYDROGEN↗

The storage performance of automotive cryo-compressed hydrogen vessels

Cryo-compressed hydrogen storage promises to deliver the highest system storage density leading to practical vehicles with range comparable to today's gasoline vehicles and fundamental cost and safety advantages. Yet, cryogenic vessels are complex systems, continuously drifting in thermodynamic space depending on use patterns, insulation performance, vessel characteristics, liquid hydrogen pump performance, and para-H 2 to ortho-H 2 conversion. In this paper, cryogenic vessel fill density results from a previous publication are extended to calculate system storage performance, including volumetric (gH 2 /L), gravimetric (H 2 weight fraction), and vent losses over a broad range of conditions. The results validate previous experiments and models indicating that cryogenic pressure vessels have maximum system density of all available storage technologies while avoiding vent losses in all but the most extreme situations. Design pressures in the range 250–350 bar seem most advantageous due to high system density and low weight and cost, although determining an optimum pressure demands a complete economic and functional analysis. Future insulation, vessel, and liquid hydrogen pump improvements are finally analyzed that, while not experimentally exhibited to date, show promise of being feasible in the future as their level of technical maturity increases, leading to maximum H 2 storage performance for cryo-compressed storage. If proven feasible and incorporated into future cryogenic vessels, these improvements will enable 50 + gH 2 /L system density at 10+% H 2 weight fraction.

08 HYDROGEN↗

Design and permitting considerations of a floating hydrogen production and dispensing Barge for the Port of San Francisco

This paper reports on the design of a Floating Hydrogen Production and Dispensing Barge destined for the Port of San Francisco (SF). The H 2 Barge is designed to produce renewable H 2 at the rate of ∼530 kg/day, storing 512 kg of hydrogen at 517-bar, allowing fast refueling of hydrogen fuel cell vessels and land-side hydrogen delivery trailers for distribution into the nascent SF hydrogen ecosystem. The broader considerations that impacted H 2 Barge design are also described. An account is given of a new review process formulated by the United States Coast Guard (USCG) to review this first-of-its-kind maritime implementation of hydrogen technology. Furthermore, the immediate goals of the H 2 Barge Project are to 1) demonstrate the feasibility, viability and methods of hydrogen production, storage and fueling in a maritime context, 2) help shape (where needed) and navigate the required local, state and federal regulatory gauntlet and 3) catalyze a “green hydrogen ecosystem” (both marine and landside) with locally produced renewable hydrogen at the San Francisco waterfront.

08 HYDROGEN↗

Numerical simulations of a horizontal axis water turbine designed for underwater mooring platforms

In order to extend the operational life of Underwater Moored Platforms (UMPs), a horizontal axis water turbine is designed to supply energy for the UMPs. The turbine, equipped with controllable blades, can be opened to generate power and charge the UMPs in moored state. Three-dimensional Computational Fluid Dynamics (CFD) simulations are performed to study the characteristics of power, thrust and the wake of the turbine. Particularly, the effect of the installation position of the turbine is considered. Simulations are based on the Reynolds Averaged Navier-Stokes (RANS) equations and the shear stress transport k-ω turbulent model is utilized. The numerical method is validated using existing experimental data. The simulation results show that this turbine has a maximum power coefficient of 0.327 when the turbine is installed near the tail of the UMP. The flow structure near the blade and in the wake are also discussed.

13 HYDRO ENERGY↗

Levelized cost of energy for a Backward Bent Duct Buoy

The Reference Model Project, supported by the U.S. Department of Energy, was developed to provide publically available technical and economic benchmarks for a variety of marine energy converters. The methodology to achieve these benchmarks is to develop public domain designs that incorporate power performance estimates, structural models, anchor and mooring designs, power conversion chain designs, and estimates of the operations and maintenance, installation, and environmental permitting required. The reference model designs are intended to be conservative, robust, and experimentally verified. The Backward Bent Duct Buoy (BBDB) presented in this paper is one of three wave energy conversion devices studied within the Reference Model Project. Comprehensive modeling of the BBDB in a Northern California climate has enabled a full levelized cost of energy (LCOE) analysis to be completed on this device.

marine hydrokinetic energy development↗

Multi-mode evaluation of power-maximizing cross-flow turbine controllers

A general method for predicting and evaluating the performance of three candidate cross-flow turbine power-maximizing controllers is presented in this paper using low-order dynamic simulation, scaled laboratory experiments, and full-scale field testing. For each testing mode and candidate controller, performance metrics quantifying energy capture (ability of a controller to maximize power), variation in torque and rotation rate (related to drive train fatigue), and variation in thrust loads (related to structural fatigue) are quantified for two purposes. First, for metrics that could be evaluated across all testing modes, we considered the accuracy with which simulation or laboratory experiments could predict performance at full scale. Second, we explored the utility of these metrics to contrast candidate controller performance. For these turbines and set of candidate controllers, energy capture was found to only differentiate controller performance in simulation, while the other explored metrics were able to predict performance of the full-scale turbine in the field with various degrees of success. Finally, effects of scale between laboratory and full-scale testing are considered, along with recommendations for future improvements to dynamic simulations and controller evaluation.

13 HYDRO ENERGY↗

A comparison of control strategies for wave energy converters

In this study, we employ a numerical model to compare the performance of a number of wave energy converter control strategies. The controllers selected for evaluation span a wide range in their requirements for implementation. Each control strategy is evaluated using a single numerical model with a set of sea states to represent a deployment site off the coast of Newport, OR. A number of metrics, ranging from power absorption to kinematics, are employed to provide a comparison of each control strategy’s performance that accounts for both relative benefits and costs. The results show a wide range of performances from the different controllers and highlight the need for a holistic design approach which considers control design as a parallel component within the larger process WEC design.

13 HYDRO ENERGY↗

A geospatial model for the analysis of time-dependent land subsidence induced by reservoir depletion

Land subsidence due to fluid depletion is an outcome of physical processes operating across a wide range of time and length scales. Although geomechanical models are crucial to simulate reservoir compaction and predict its long-term fate, their use across large regions often bears prohibitive computational costs. To overcome this obstacle, this paper proposes a simplified modelling framework consisting of (i) a near-field numerical solver simulating the coupling between fluid flow and rock deformation with reference to a simplified one-dimensional geometry and (ii) a far-field geospatial algorithm mapping ground settlements across a region through the superposition of poroelastic computations at multiple wells. The model computes the delay between depletion history and reservoir compaction in proximity of a producing well by assuming basal depletion of a fluid-saturated deformable disk, while the Geertsma solution of nucleus of strain is used to extrapolate the impact of such time-varying reservoir compaction around the well. This approach has been used to back-analyze the spatio-temporal progression of subsidence at the Groningen gas field. The results are compared against measurements collected over 50 year of production at 25 benchmark locations scattered over an area of 900 km 2 . It is shown that coupled simulations based on average values of rock compressibility and permeability lead to nonlinear trends of subsidence evolution in good agreement with field measurements, while uncoupled analyses overpredict settlements by more than 70%. Lastly, synthetic forecasts based on different rates of depletion were provided. The results suggest that slower depletion rates lead to lower subsidence at a given time, and that residual subsidence may continue to develop for several decades after interruption of production activities.

58 GEOSCIENCES↗

Development and Validation of a Prognostic Model Using Blood Biomarker Information for Prediction of Survival of Non-Small-Cell Lung Cancer Patients Treated With Combined Chemotherapy and Radiation or Radiotherapy Alone (NCT00181519, NCT00573040, and NCT00572325)

Purpose: Currently, prediction of survival for non-small-cell lung cancer patients treated with (chemo)radiotherapy is mainly based on clinical factors. The hypothesis of this prospective study was that blood biomarkers related to hypoxia, inflammation, and tumor load would have an added prognostic value for predicting survival. Methods and Materials: Clinical data and blood samples were collected prospectively (NCT00181519, NCT00573040, and NCT00572325) from 106 inoperable non-small-cell lung cancer patients (Stages I-IIIB), treated with curative intent with radiotherapy alone or combined with chemotherapy. Blood biomarkers, including lactate dehydrogenase, C-reactive protein, osteopontin, carbonic anhydrase IX, interleukin (IL) 6, IL-8, carcinoembryonic antigen (CEA), and cytokeratin fragment 21-1, were measured. A multivariate model, built on a large patient population (N = 322) and externally validated, was used as a baseline model. An extended model was created by selecting additional biomarkers. The model's performance was expressed as the area under the curve (AUC) of the receiver operating characteristic and assessed by use of leave-one-out cross validation as well as a validation cohort (n = 52). Results: The baseline model consisted of gender, World Health Organization performance status, forced expiratory volume, number of positive lymph node stations, and gross tumor volume and yielded an AUC of 0.72. The extended model included two additional blood biomarkers (CEA and IL-6) and resulted in a leave-one-out AUC of 0.81. The performance of the extended model was significantly better than the clinical model (p = 0.004). The AUC on the validation cohort was 0.66 and 0.76, respectively. Conclusions: The performance of the prognostic model for survival improved markedly by adding two blood biomarkers: CEA and IL-6.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prognostic Cell Biological Markers in Cervical Cancer Patients Primarily Treated With (Chemo)radiation: A Systematic Review

The aim of this study was to systematically review the prognostic and predictive significance of cell biological markers in cervical cancer patients primarily treated with (chemo)radiation. A PubMed, Embase, and Cochrane literature search was performed. Studies describing a relation between a cell biological marker and survival in {>=}50 cervical cancer patients primarily treated with (chemo)radiation were selected. Study quality was assessed, and studies with a quality score of 4 or lower were excluded. Cell biological markers were clustered on biological function, and the prognostic and predictive significance of these markers was described. In total, 42 studies concerning 82 cell biological markers were included in this systematic review. In addition to cyclooxygenase-2 (COX-2) and serum squamous cell carcinoma antigen (SCC-ag) levels, markers associated with poor prognosis were involved in epidermal growth factor receptor (EGFR) signaling (EGFR and C-erbB-2) and in angiogenesis and hypoxia (carbonic anhydrase 9 and hypoxia-inducible factor-1{alpha}). Epidermal growth factor receptor and C-erbB-2 were also associated with poor response to (chemo)radiation. In conclusion, EGFR signaling is associated with poor prognosis and response to therapy in cervical cancer patients primarily treated with (chemo)radiation, whereas markers involved in angiogenesis and hypoxia, COX-2, and serum SCC-ag levels are associated with a poor prognosis. Therefore, targeting these pathways in combination with chemoradiation may improve survival in advanced-stage cervical cancer patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High Stromal Carbonic Anhydrase IX Expression Is Associated With Decreased Survival in p16-Negative Head-and-Neck Tumors

Purpose: Head-and-neck squamous cell carcinoma (HNSCC) is the fifth most common malignancy worldwide. Alcohol use and tobacco use are the most established risk factors; however, human papilloma virus (HPV) infection is a major risk factor for a subset of HNSCCs. Although HPV-positive tumors typically present at a more advanced stage at diagnosis, they are associated with a better prognosis. Tumor hypoxia confers poor prognosis and treatment failure, but direct tumor oxygen measurement is challenging. Endogenous markers of hypoxia (EMHs) have been proposed but have not replicated the prognostic utility of direct oxygen measurement. The expression of endogenous markers of hypoxia may be influenced by oxygen-independent factors, such as the HPV status of the tumor. Methods and Materials: Consecutive cases of locally advanced HNSCC, treated with a uniform regimen of combined radiotherapy and chemotherapy, were identified. Tissue microarrays were assembled from triplicate 0.6-mm cores of archived tumor tissue. HPV status was inferred from semiquantitative p16 immunostaining and directly measured by use of HPV-specific chromogenic in situ hybridization and polymerase chain reaction. Automated quantitative fluorescent immunohistochemistry was conducted to measure epithelial and stromal expression of carbonic anhydrase IX (CAIX) and glucose transporter 1 (GLUT1). Results: High stromal CAIX expression was associated with significantly reduced overall survival (p = 0.03) in patients with p16-negative tumors. Conclusions: This is the first study to use quantitative immunohistochemistry to examine endogenous markers of hypoxia stratified by tumor p16/HPV status. Assessment of CAIX expression in p16-negative HNSCC could identify patients with the least favorable prognosis and inform therapeutic strategies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Refine your search to explore more results.