Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heating systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Report on Year-3 of Water NSTF Matrix Testing: Two-Phase Parametric Test Series

The Natural convection Shutdown heat removal Test Facility (NSTF) is large scale test facility constructed at Argonne National Laboratory to generate NQA-1 qualified validation data for passive decay heat removal systems in advanced reactor concepts. With support from the Department of Energy (DOE) offices of Advanced Reactor Technologies (ART) and Advanced Reactors Regulatory Development (RD), this facility reflects key features of a ½ scale, water-based, Reactor Cavity Cooling System (RCCS) and is intended to study the behavior, bound performance, and ultimately guide design decisions for passive decay heat removal systems. Since the facility also retains all aspects common to a fundamental boiling water thermosiphon, the generated experimental data sets are well poised to advance the understanding of fundamental natural circulation boiling and two-phase flow phenomena.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Clemson Hydrogen Combined Heat and Power Storage System

The objective of this project named H2 Orange, was to develop a conceptual design including a technoeconomic study, technology gap assessment and maturation plan, and commercialization plan of a nominal 50-megawatt hours (MWh) hydrogen energy storage system. The project investigated how to optimally size, design and integrate the hydrogen energy storage system with an existing 14.3-megawatt (MW) gas turbine fossil asset supplying thermal power at the Clemson University Combined Heat & Power (CHP) plant.

03 NATURAL GAS↗

Waste-Heat-Driven Cooling Using Complex Compound Sorbents

Improved complex-compound sorption pumps are undergoing development for use as prime movers in heat-pump systems for cooling and dehumidification of habitats for humans on the Moon and for residential and commercial cooling on Earth. Among the advantages of sorption heat-pump systems are that they contain no moving parts except for check valves and they can be driven by heat from diverse sources: examples include waste heat from generation of electric power, solar heat, or heat from combustion of natural gas. The use of complex compound sorbents in cooling cycles is not new in itself: Marketing of residential refrigerators using SrCl2 was attempted in the 1920s and 30s and was abandoned because heat- and mass-transfer rates of the sorbents were too low. Addressing the issue that gave rise to the prior abandonment of complex compound sorption heat pumps, the primary accomplishment of the present development program thus far has been the characterization of many candidate sorption media, leading to large increases in achievable heat- and mass-transfer rates. In particular, two complex compounds (called "CC260-1260" and "CC260-2000") were found to be capable of functioning over the temperature range of interest for the lunar-habitat application and to offer heat- and mass-transfer rates and a temperature-lift capability adequate for that application. Regarding the temperature range: A heat pump based on either of these compounds is capable of providing a 95-K lift from a habitable temperature to a heat-rejection (radiator) temperature when driven by waste heat at an input temperature .500 K. Regarding the heat- and mass-transfer rates or, more precisely, the power densities made possible by these rates: Power densities observed in tests were 0.3 kilowatt of cooling per kilogram of sorbent and 2 kilowatts of heating per kilogram of sorbent. A prototype 1-kilowatt heat pump based on CC260-2000 has been built and demonstrated to function successfully.

Rocketfeller, Uwe↗

High-Temperature Heat Transfer Fluid Circulator for Concentrating Solar Power Systems

A high temperature Heat Transfer Fluid circulator compressor with wide turn down ratio aerodynamic performance was designed, fabricated and tested for application with high pressure super Critical CO2 fluid capable of temperatures and pressures to >750°C and 25 MPa respectively. The modular system decoupled the drive motor system from an independent compressor shaft to provide thermal isolation between the high temperature compressor shaft and the lower temperature capable motor elements. While the thermal management approach appears to be viable there are potential losses in the secondary cooling flows that need to be taken into account and fine-tuned during operation in order to achieve desired overall system efficiencies. The system was also shown to be viable and dynamically stable throughout the entire operating speed range, thereby validating the overall system configuration and structural design approach used. Finally, while it was not possible to achieve specific PTC-10 test points, the compressor performance tests provide sufficient data to indicate that the compressor has the ability to achieve the required performance in practice. The two key factors affecting compressor design and cost are the maximum expected temperature and pressure. The maximum allowable temperatures for current state-of-the-art (SOA) motor driven compressor technology is limited to of approximately 150-200°C, but inlet temperatures >750 °C may be encountered. While the optimal efficiency of compression is in the transcritical region, some concepts require inlet pressures to 225 bar.

14 SOLAR ENERGY↗

Solar-powered Rankine heat pump for heating and cooling

The design, operation and performance of a familyy of solar heating and cooling systems are discussed. The systems feature a reversible heat pump operating with R-11 as the working fluid and using a motor-driven centrifugal compressor. In the cooling mode, solar energy provides the heat source for a Rankine power loop. The system is operational with heat source temperatures ranging from 155 to 220 F; the estimated coefficient of performance is 0.7. In the heating mode, the vapor-cycle heat pump processes solar energy collected at low temperatures (40 to 80 F). The speed of the compressor can be adjusted so that the heat pump capacity matches the load, allowing a seasonal coefficient of performance of about 8 to be attained.

Rousseau, J.↗

Progress in Fast Modular Reactor Conceptual Design

The Fast Modular Reactor (FMR) is a 100-MW(thermal) gas-cooled fast reactor being developed by General Atomics Electromagnetic System with the goal of developing a FMR for flexible and dispatchable power to the U.S. electricity market in the mid-2030s. The conceptual design aims to develop and verify simplified design features. These include an inert helium gas coolant, pellet-loaded fuel rods, installations with air cooling as ultimate heat sink, and small and passive heat removal systems. The goal is to ensure the development of a safe, maintainable, cost-effective, and distributed nuclear energy-generating station. The baseline technologies selected to achieve this goal are a helium coolant that is an inert gas with no chemical reaction with structural components, not activated, single phase, enabling high-temperature operation and a high thermal efficiency Brayton cycle; conventional uranium dioxide (UO 2 ) fuel, which is the most widely used and well-known fuel material, capable of high burnup (100 MWd/kg) and a long fuel life; and silicon carbide composite (SiGA®) cladding and internal structures that are chemically inert in the helium environment, exceptionally radiation tolerant, and being derisked by accident tolerant fuel technology development. Further, the reactor was specifically designed with passive safety features, including high-temperature in-core materials and a reactor vessel cooling system consisting of cooling panels of naturally circulating water. The passive safety of the core was confirmed for the depressurized loss-of–forced cooling accident, which showed the peak cladding temperature at ~1600°C during the transient, which is below the current design limit of 1800°C. The conceptual design of the FMR has been conducted for the reactor system, vessel system, generator and turbomachine, instrumentation and control, residual heat removal system, plant service system, and containment, as well as pre-application licensing documents.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Investigation of ventilation-coupled high energy density sensible thermal energy storage

Low-cost energy storage will play an important role in supporting the decarbonization of the energy sector. Here, a novel approach to thermal energy storage for buildings is proposed, in which a tank of antifreeze liquid can be used to heat outdoor air in mechanical ventilation systems. If heated to a high enough temperature, the fluid can potentially undergo temperature swings of nearly 100°C during discharge in cold climates. Because the energy density of sensible storage systems scales proportionally to the system temperature change, this concept has the potential to offer higher energy densities than other liquid-based sensible storage devices used in building applications. A one-dimensional numerical model of the storage system was developed and experimentally validated using 30 wt% (wt%) potassium acetate as an aqueous antifreeze solution. Using a commercial hot water tank, energy densities of 47.0 kW-hour per cubic meter (kWh/m 3 ) were demonstrated in a laboratory setting. Material energy densities of approximately 74.7 (kWh/m 3 ) were measured. Design improvements may boost this energy storage density even further. Because of the system's relative simplicity, ventilation-coupled sensible storage has the potential to be an easily deployable, low-cost energy storage solution for building systems.

25 ENERGY STORAGE↗

Life characteristics assessment of the communications technology satellite transmitter experiment package

The performance characteristics of the transmitter experiment package (TEP) aboard the Communications Technology Satellite (CTS) measured during its first 2 years in orbit are presented. The TEP consists of a nominal 200 watt output stage tube (OST), a supporting power processing system (PPS), and a variable conductance heat pipe system (VCHPS). The OST, a traveling wave tube augmented with a 10 stage depressed collector has an overall saturated average efficiency of 51.5 percent and an average saturated radio frequency (rf) output power at center band frequency of 240 watts. The PPS operated with a measured efficiency of 86.5 to 88.5 percent. The VCHPS, using three pipes to conduct heat from the PPS and the OST to a 52 by 124 centimeter radiator fin, maintained the PPS baseplate temperature below 50 C for all operating conditions. The TEP performance characteristics presented include frequency response, rf output power, thermal performance, and efficiency. Communications characteristics were evaluated by using both video and audio modulated signals. On four occasions, the TEP experienced temporary thermal control system malfunctions. The anomalies were terminated safely, and the problem was investigated because of the potential for TEP damage due to the signficant temperature increases. Safe TEP operating procedures were established.

Smetana, J.↗

Central Data Processing System (CDPS) user's manual: Solar heating and cooling program

The software and data base management system required to assess the performance of solar heating and cooling systems installed at multiple sites is presented. The instrumentation data associated with these systems is collected, processed, and presented in a form which supported continuity of performance evaluation across all applications. The CDPS consisted of three major elements: communication interface computer, central data processing computer, and performance evaluation data base. Users of the performance data base were identified, and procedures for operation, and guidelines for software maintenance were outlined. The manual also defined the output capabilities of the CDPS in support of external users of the system.

Source record↗

A Universal Refrigerant Charge Fault Detection and Diagnostics Method Based on Pump Down Operation

The performance of the heat pump system varies greatly depending on the refrigerant charge amount. Improving the refrigerant charge fault detection and diagnostics (FDD) method of vapor compression systems have the potential for increasing energy efficiency and reducing service cost. Previous studies to predict refrigerant charge amount are mostly empirical methods which require significant amount of experimental data for high accuracy. The primary goal of this research is to develop a universal charge fault detection method which requires only a few experimental data with high prediction accuracy.Currently, pump down operations are typical practices by HVAC technicians when they need to open the refrigerant circuit to make a repairment. In addition, compressors have a built-in low-pressure cut-off protection function, and the compressor performance maps are commonly available from manufacturers. The proposed method innovatively utilizes the typical pump down operation, the compressor low-pressure cut-off protection, and the compressor performance map. It does not require any geometry information of heat exchangers, refrigerant lines, or charge buffers.The new charge prediction method is firstly formulated through theoretical analysis, then verified and calibrated by a quasi-steady-state simulation of the pump down process for a residential heat pump system. The quasi steady-state simulation uses an HVAC system simulation framework driven by DOE/ORNL Heat Pump Design Model (HPDM). Preliminary experiment validations with heat pump refrigerant leakage tests demonstrate the deviation of the proposed charge prediction method compared with measurement is within 8%. This technology makes refrigerant charge amount available at the technician’s fingertips and leads to shorter maintenance time and fewer site visits.

Li, Zhenning↗

Linear dynamic analysis of the Space Station Freedom thermal/environmental control system

A methodology for dynamic analysis of the Space Station Freedom thermal/environmental control system is described which uses linear system analysis techniques to determine the ability of the system to accommodate thermal load transients. A nonlinear integrated model of the system as it exists at Stage 6, Man Tended Capability (MTC), is described which encompasses the cabin air cooling system, avionics air cooling system, internal and external thermal control systems. The nonlinear model is linearized at an assumed design operating point, and the linear model is evaluated by comparison with the nonlinear model. Transfer functions are derived to determine the response of the heat rejection system to time-varying thermal loads applied at various points in the heat acquisition system. The frequency response calculated from the transfer functions is used to determine allowable operating envelopes of thermal load magnitude and frequency for each point of application of thermal load. The dynamic operating envelopes provide a quantitative indication of the degree and duration of peak loads which the thermal/environmental system is able to transport and reject.

Tandler, John↗

Europa Clipper Thermal Control Design

This paper details the design developments of the Europa Clipper spacecraft thermal control system and its primary element the Heat Redistribution System (HRS). The Europa Clipper spacecraft will launch in the early 2020s and will have multiple flybys of Jupiter’s icy moon, Europa. The HRS, which utilizes a Mechanically Pumped Fluid Loop (MPFL) to reclaim waste heat from an avionics vault module and redistribute it to the propulsion module and radiator, has become an integral part of the spacecraft architecture both in terms of mechanical configuration and spacecraft operations capability. A walkthrough on the planned implementation of the HRS on the primary spacecraft modules is provided along with a description on thermal control of spacecraft hardware not located on the HRS vault, where thermal isolation and tolerance to extreme thermal environment drives the hardware designs.

Bhandari, Pradeep↗

Waste Heat Recapture from Supermarket Refrigeration Systems

The objective of this project was to determine the potential energy savings associated with improved utilization of waste heat from supermarket refrigeration systems. Existing and advanced strategies for waste heat recovery in supermarkets were analyzed, including options from advanced sources such as combined heat and power (CHP), micro-turbines and fuel cells.

30 DIRECT ENERGY CONVERSION↗

The pre-conceptual design of the nuclear island of ASTRID

The CEA is involved in a substantial effort on the ASTRID (Advanced Sodium Technological Reactor for Industrial Demonstration) pre-conceptual design in cooperation with EDF, as experienced Sodium-cooled Fast Reactor (SFR) operator, AREVA, as experienced SFR Nuclear Island engineering company and components designer, ALSTOM POWER as energy conversion system designer and COMEX NUCLEAIRE as mechanical systems designer. The CEA is looking for other partnerships, in France and abroad. The ASTRID preliminary design is based on a sodium-cooled pool reactor of 1500 MWth generating about 600 MWe, which is required to guarantee the representativeness of the reactor core and the main components with regard to future commercial reactors. ASTRID lifetime target is 60 years. Two Energy Conversion Systems are studied in parallel until the end of 2012: Rankine steam cycle or Brayton gas based energy conversion cycle. ASTRID design is guided by the following major objectives: improved safety, simplification of structures, improved In Service Inspection and Repair (ISIR), improved manufacturing conditions for cost reduction and increased quality, reduction of risks related to sodium fires and water/sodium reaction, and improved robustness against external hazards. The core is supported by a diagrid, which lay on a strong back to transfer the weight to the main vessel. AREVA is involved in a substantial effort in order to improve the core support structure in particular regarding the ISIR and the connection to primary pump. In the preliminary design, the primary system is formed by the main vessel and the upper closure comprising the reactor roof, two rotating plugs - used for fuel handling - and the components plugs located in the roof penetrations. The Above Core Structure deflects the sodium flow in the hot pool and provides support to core instrumentation and guidance of the control rod drive mechanisms. The number of the major components in the main vessel, primary pumps, Intermediate Heat Exchangers, and Decay Heat Exchangers are now under consideration. Under normal conditions, power release is achieved using the steam/water plant (in case of Rankine steam cycle) or the gas plant (in case of Brayton gas cycle). The diverse design and operating modes of Decay Heat Removal systems provide protection against common cause failures. A Decay Heat Removal system through the reactor vault is in particular studied with the objective to complement Direct Reactor Cooling systems. At this stage of the studies, the secondary system comprises four independent sodium loops (two and three sodium loops configurations are also investigated). Each loop includes one mechanical pump (or a large capacity Annular Linear Induction Electromagnetic Pump), and three modular Steam Generator Units characterized by once through straight tube units with a ferritic tube bundle; nevertheless, helical coil steam generator with tubes made of Alloy 800, and inverted type steam generator with a ferritic tube bundle are also investigated. The limited power of each modular Steam Generator Unit allows the whole secondary loop to withstand a large water/sodium reaction consecutive to the postulated simultaneous rupture of all the heat exchange tubes of one module. The arrangement of the components is based on the 'Regain' concept, in which the secondary pump is situated at a low level in the circuit; conventional arrangement, as SUPERPHENIX type, is a back-up option. Alternative arrangements based on gas cycles are also studied together with Na-gas heat exchanger design. This paper presents a status of the ASTRID pre-conceptual design. The most promising options are highlighted as well as less risky and back-up options. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Refine your search to explore more results.