Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heat”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Prioritizing urban heat adaptation infrastructure based on multiple outcomes: Comfort, health, and energy

Globally, cities face increasing extreme heat, impacting comfort, health, and energy consumption. Infrastructure-based heat adaptation strategies can improve these outcomes, but each strategy has a unique mix of benefits and drawbacks. Here, we apply an urbanized meteorological model (WRF) with the newly integrated multilayer BEP-Tree street tree model to dynamically downscale Earth System Model projections and a 3-D microclimate model (TUF-Pedestrian) to simulate the street-scale radiation environment impacting pedestrians. We evaluate the performance of five heat adaptation strategies (street trees, cool roofs, green roofs, rooftop photovoltaics (PV), and reflective pavements) during extreme heat events in three cities with contrasting background climates (Toronto, Phoenix, and Miami), under contemporary and end-of-century projected climates, based on three metrics: outdoor heat stress, air conditioning (AC) energy use, and ventilation of vehicular air pollution. No single adaptation strategy improves all three outcomes. While street trees inhibit ventilation, they reduce outdoor heat stress four times more effectively than the next best strategy via shade provision, fully offsetting heat stress increases under a high-emissions end-of-century climate scenario in all cities studied. Cool roofs and green roofs moderately reduce heat stress and energy use. Alternatively, rooftop PV with energy storage can generate sufficient power for space cooling but have marginal effects on heat stress. Reflective pavements are the least effective across metrics. Where the ventilation of street-level emissions is of less concern, our results clearly support the combination of street trees and rooftop PV as a highly complementary and effective means of adaptive mitigation across different climates and neighborhood densities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

PLASMA HEATING DURING A CORONAL MASS EJECTION OBSERVED BY THE SOLAR AND HELIOSPHERIC OBSERVATORY

We perform a time-dependent ionization analysis to constrain plasma heating requirements during a fast partial halo coronal mass ejection (CME) observed on 2000 June 28 by the Ultraviolet Coronagraph Spectrometer (UVCS) aboard the Solar and Heliospheric Observatory (SOHO). We use two methods to derive densities from the UVCS measurements, including a density sensitive O V line ratio at 1213.85 and 1218.35 A, and radiative pumping of the O VI {lambda}{lambda}1032, 1038 doublet by chromospheric emission lines. The most strongly constrained feature shows cumulative plasma heating comparable to or greater than the kinetic energy, while features observed earlier during the event show plasma heating of order or less than the kinetic energy. SOHO Michelson Doppler Imager observations are used to estimate the active region magnetic energy. We consider candidate plasma heating mechanisms and provide constraints when possible. Because this CME was associated with a relatively weak flare, the contribution from flare energy (e.g., through thermal conduction or energetic particles) is probably small; however, the flare may have been partially behind the limb. Wave heating by photospheric motions requires heating rates to be significantly larger than those previously inferred for coronal holes, but the eruption itself could drive waves that heat the plasma. Heating by small-scale reconnection in the flux rope or by the CME current sheet is not significantly constrained. UVCS line widths suggest that turbulence must be replenished continually and dissipated on timescales shorter than the propagation time in order to be an intermediate step in CME heating.

79 ASTRONOMY AND ASTROPHYSICS↗

PHOTOCHEMICAL HEATING OF DENSE MOLECULAR GAS

Photochemical heating is analyzed with an emphasis on the heating generated by chemical reactions initiated by the products of photodissociation and photoionization. The immediate products are slowed down by collisions with the ambient gas and then heat the gas. In addition to this direct process, heating is also produced by the subsequent chemical reactions initiated by these products. Some of this chemical heating comes from the kinetic energy of the reaction products and the rest from collisional de-excitation of the product atoms and molecules. In considering dense gas dominated by molecular hydrogen, we find that the chemical heating is sometimes as large, if not much larger than, the direct heating. In very dense gas, the total photochemical heating approaches 10 eV per photodissociation (or photoionization), competitive with other ways of heating molecular gas.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hydronic Heating Coil Versus Propane Furnace, Rehoboth Beach, Delaware (Fact Sheet)

Insight Homes constructed two houses in Rehoboth Beach, Delaware, with identical floor plans and thermal envelopes but different heating and domestic hot water (DHW) systems. Each house is 1,715-ft 2 with a single story, three bedrooms, two bathrooms, and the heating, ventilation, and air conditioning (HVAC) systems and ductwork located in conditioned crawlspaces. The standard house, which the builder offers as its standard production house, uses an air source heat pump (ASHP) with supplemental propane furnace heating. The Building America test house uses the same ASHP unit with supplemental heat provided by the DHW heater (a combined DHW and hydronic heating system, where the hydronic heating element is in the air handler). Both houses were occupied during the test period. Results indicate that efficiency of the two heating systems was not significantly different. Three issues dominate these results; lower system design performance resulting from the indoor refrigerant coil selected for the standard house, an incorrectly functioning defrost cycle in the standard house, and the low resolution of the natural gas monitoring equipment. The thermal comfort of both houses fell outside the ASHRAE Standard 55 heating range but was within the ACCA room-to-room temperature range when compared to the thermostat temperature. The monitored DHW draw schedules were input into EnergyPlus to evaluate the efficiency of the tankless hot water heater model using the two monitored profiles and the Building America House Simulation Protocols. The results indicate that the simulation is not significantly impacted by the draw profiles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Evaluation and Costs of a Combined Ground Source Heat Pump and Solar Photovoltaic Storage System in an Extreme Cold Climate

This report outlines the effectiveness and economics of a ground source heat pump system installed together with solar photovoltaic panels and a battery storage system in a local community building situated in a cold climate. The community building is a tribal building located in Ruby, Alaska. Power from solar photovoltaic panels is supplemented by electricity purchased from the local community microgrid. A ground source heat pump was commissioned three years after the building was occupied, and supplements the heat generated by a boiler for both heat and domestic hot water. Data collected over the 2021-2022 heating season shows that the heat pump is providing heat to the building about 19% of the time with an average coefficient of performance of 2.68, ranging from below 2.5 in winter to above 3.0 in summer. The solar photovoltaic panels provided 4,700 kWh of power used within the building and an additional 2,900 kWh exported to the microgrid. The solar-produced power used within the building nearly offsets the estimated annual electrical draw of the heat pump of 5,700 kWh. Due to the very high costs for shipping and installation to remote locations, projects such as this, while not economically feasible if self-funded, can save the community an estimated $76,051 over a period of 20-years. Fuel prices increasing by more than 25%, or subsidized electricity prices decreasing by more than 25%, make the ground source heat pump a more viable option economically. Unsubsidized electricity prices increasing by 25% or more make a solar photovoltaic system with battery storage nearly economically viable after a 20-year period for commercial or school buildings that are not eligible for Alaska's Power Cost Equalization program.

14 SOLAR ENERGY↗

Experimental Investigation of the Heat Transfer between Finned Tubes and a Bubbling Fluidized Bed with Horizontal Sand Mass Flow

The sandTES technology utilizes a fluidized bed counter current heat exchanger for thermal energy storage applications. Its main feature is an imposed horizontal flow of sand (SiO2) particles fluidized by a vertical air flow across a heat exchanger consisting of several horizontal rows of tubes. Past international research on heat transfer in dense fluidized beds has focused on stationary (stirred tank) systems, and there is little to no information available on the impact of longitudinal or helical fins. Previous pilot plant scale experiments at TU Wien led to the conclusion that the currently available correlations for predicting the heat transfer coefficient between the tube surface and the surrounding fluidized bed are insufficient for the horizontal sand flow imposed by the sandTES technology. Therefore, several smaller test rigs were designed in this study to investigate the influence of different tube arrangements and flow conditions on the external convective heat transfer coefficient and possible improvements by using finned tubes. It could be shown that helically finned tubes in a transversal arrangement, where the horizontal sand flow is perpendicular to the tube axes, allows an increase in the heat transfer coefficient per tube length (i.e., the virtual heat transfer coefficient) by a factor of 3.5 to about 1250 W/m2K at ambient temperature. Based on the literature, this heat transfer coefficient is expected to increase at higher temperatures. The new design criteria allow the design of compact, low-cost heat exchangers for thermal energy storage applications, in particular electro-thermal energy storage.

25 ENERGY STORAGE↗

Thermal performance of a multi-evaporator loop heat pipe with thermal masses and thermal electrical coolers

This paper describes thermal performance of a loop heat pipe (LHP) with two evaporators and two condensers in ambient testing. Each evaporator has an outer diameter of 15mm and a length of 76mm, and has an integral compensation chamber (CC). An aluminum mass of 500 grams is attached to each evaporator to simulate the instrument mass. A thermal electric cooler (TEC) is installed on each CC to provide heating as well as cooling for CC temperature control. A flow regulator is installed in the condenser section to prevent vapor from going back to the evaporators in the event that one of condenser is fully utilized. Ammonia was used ad the working fluid. Tests conducted included start-up, power cycle, heat load sharing, sink temperature cycle, operating temperature control with TECs, and capillary limit tests. Experimental data showed that the loop could start with a heat load of less than 1OW even with added thermal masses. The loop operated stably with even and uneven evaporator heat loads, and even and uneven condenser sink temperatures. The operating temperature could be controlled within +/-0.5K of the set point temperature using either or both TECs, and the required TEC control heater power was less than 2W under most test conditions. Heat load sharing between the two evaporators was also successfully demonstrated. The loop had a heat transport capability of 120W to 140W, and could recover from a dry-out when the heat load was reduced. The 500-gram aluminum mass on each evaporator had a negligible effect on the loop operation. Existing LHPs servicing the orbiting spacecraft have a single evaporator with an outer diameter of about 25mm. Important performance characteristics demonstrated by this LHP included: 1) Operation of an LHP with 15mm diameter evaporators; 2) Robustness and reliability of an LHP with multiple evaporators and multiple condensers under various test conditions; 3) Heat load sharing among LHP evaporators; 4) Effectiveness of TECs in controlling the LHP operating temperature; and 5) Effectiveness of the flow regulator in preventing vapor from going back the evaporators.

loop heat pipes↗

Examining Runner’s Outdoor Heat Exposure Using Urban Microclimate Modeling and GPS Trajectory Mining

It is important to quantify human heat exposure in order to evaluate and mitigate the negative impacts of heat on human well-being in the context of global warming. This study proposed a human-centric framework to examine human personal heat exposure based on anonymous GPS trajectories data mining and urban microclimate modeling. The mean radiant temperature (Tmrt) that represents the human body’s energy balance was used to indicate human heat exposure. The meteorological data and high-resolution 3D urban model generated from multispectral remotely sensed images and LiDAR data were used as inputs in urban microclimate modeling to map the spatio-temporal distribution of the Tmrt in the Boston metropolitan area. The anonymous human GPS trajectory data collected from fitness Apps was used to map the spatiotemporal distribution of human outdoor activities. By overlaying the anonymous GPS trajectories on the generated spatio-temporal maps of Tmrt, this study further examined the heat exposure of runners in different age-gender groups in the Boston area. Results show that there is no significant difference in terms of heat exposure for female and male runners. The female runners in the age of 45-54 are exposed to more heat than female runners of 18-24 and 25-34, while there is no significant difference among male runners. This study proposed a novel method to estimate human heat exposure, which would shed new light on mitigating the negative impacts of heat on human health.

Personal heat exposure↗

New Whole-House Solutions Case Study: Testing Ductless Heat Pumps in High-Performance Affordable Housing, the Woods at Golden Given - Tacoma, Washington

The Woods is a 30-home, high- performance, energy efficient sustainable community built by Habitat for Humanity (HFH). With Support from Tacoma Public Utilities, Washington State University (part of the Building America Partnership for Improved Residential Construction) is researching the energy performance of these homes and the ductless heat pumps (DHP) they employ. This project provides Building America with an opportunity to: field test HVAC equipment, ventilation system air flows, building envelope tightness, lighting, appliance, and other input data that are required for preliminary Building Energy Optimization (BEopt™) modeling and ENERGY STAR® field verification; analyze cost data from HFH and other sources related to building-efficiency measures that focus on the DHP/hybrid heating system and heat recovery ventilation system; evaluate the thermal performance and cost benefit of DHP/hybrid heating systems in these homes from the perspective of homeowners; compare the space heating energy consumption of a DHP/electric resistance (ER) hybrid heating system to that of a traditional zonal ER heating system; conduct weekly "flip-flop tests" to compare space heating, temperature, and relative humidity in ER zonal heating mode to DHP/ER mode.

Appliance↗

Experimental Studies of Particle Acceleration and Heating During Magnetic Reconnection

Energy conversion from magnetic energy to particle energy during magnetic reconnection is studied in the collisionless plasma of the Magnetic Reconnection Experiment (MRX). The plasma is in the two-fluid regime, where the ion motion is decoupled from that of the electron within the so-called ion diffusion region. For ion heating and acceleration, the role of the in-plane (Hall) electric field is emphasized. The in-plane potential responsible for the Hall electric field is established by electrons that are accelerated near the small electron diffusion region. The in-plane electrostatic potential profile shows a well structure along the direction normal to the reconnection current sheet that becomes deeper and wider downstream as its boundary expands along the separatrices where the in-plane electric field is strongest. Since the Hall electric field is 3--4 times larger than the reconnection electric field, unmagnetized ions obtain energy mostly from the in-plane electric field, especially near the separatrices. The Hall electric field ballistically accelerates ions near the separatrices toward the outflow direction. After ions are accelerated, they are heated as they travel into the high pressure downstream region. This downstream ion heating cannot be explained by classical, unmagnetized transport theory, which suggests that the magnetic field should be important due to an effect called re-magnetization. Electrons are also significantly heated during reconnection. The electron temperature sharply increases across the separatrices and peaks just outside of the electron diffusion region. Unlike ions, electrons acquire energy mostly from the reconnection electric field and the energy gain is localized near the X-point. However, the electron bulk flow energy increase remains negligible. These observations support the assertion that efficient electron heating mechanisms exist around the electron diffusion region and that the generated heat is quickly transported along the magnetic field due to the high parallel thermal conductivity of electrons. Classical Ohmic dissipation based on the perpendicular Spitzer resistivity is too small to compensate the heat flux, indicating the presence of anomalous electron heating. Finally, a total energy inventory is calculated based on analysis of the Poynting, enthalpy, flow energy, and heat flux in the measured diffusion layer. More than half of the incoming magnetic energy is converted to particle energy during collisionless reconnection. Unlike in the Sweet-Parker model, the outgoing Poynting flux is not negligible, which is due to considerable Hall fields, i.e., the quadrupole out-of-plane magnetic field and the in-plane electric field. The total ion energy gain during reconnection is larger than that of electrons, since the energy gain occurs over a broader region. The total ion thermal energy gain is larger than the increase of the ion flow energy. Finally, the electron thermal energy gain is comparable to the ion thermal energy gain, while the electron flow energy remains insignificant.

electron heating↗

Design and Development of a Residential Gas-Fired Heat Pump

Heating, ventilating, and air-conditioning equipment consumes 43% of the total primary energy consumption in U.S. households. Presently, conventional gas furnaces have maximum heating efficiencies of 98%. Electric air conditioners used in association with the furnace for cooling have a minimum seasonal energy efficiency ratio (SEER) of 14.0. A residential gas-fired heat pump (RGHP) was developed and tested under standard rating conditions, resulting in a significant increase in heating efficiency of over 40% versus conventional natural gas furnaces. The associated efficiency of the RGHP in cooling mode is comparable in efficiency to an electric air conditioner (14.0 SEER) when compared on a primary energy basis. The RGHP is similar in nature to a conventional heat pump but with two main differences. First, the primary energy savings are higher, based on a site versus source comparison, as the result of using natural gas to supply shaft power to the compressor rather than an electric motor. Second, waste heat is recovered from the engine to supplement space heating and reduce the energy input. It can also be used to provide supplemental water heating. The system utilizes a programmable logic controller that allows variable-speed operation to achieve improved control to meet building loads. RGHPs significantly reduce peak electric use during periods of high demand, especially peak summer loads, as well as peak winter loads in regions with widespread use of electric heating. This contributes to leveling year-round gas loads, with the potential to increase annual gas demand in some regions. The widespread adoption of RGHPs will contribute to significant reductions in primary energy consumption and carbon emissions through improved efficiencies.

energy efficiency↗

Building America Case Study: Indoor Heat Pump Water Heaters During Summer in a Hot-Dry Climate, Redding, California

Heat pump water heaters offer a significant opportunity to improve water heating performance for the over 40% of U.S. households that heat domestic hot water using electric resistance storage water heaters. Numerous field studies have also been completed documenting performance in a variety of climates and applications. More recent evaluation efforts have focused attention on the performance of May through September 2014, with ongoing winter monitoring being sponsored by California utility partners. Summer results show favorable system performance with extrapolated annual water heating savings of 1,466 to 2,300 kWh per year, based on the observed hot water loads. Additional summer space cooling benefits savings of 121 to 135 kWh per year were projected, further increasing the water heating savings by 5-9%. Given the project schedule for 2014 completion, no heating season impacts were able to be monitored. May through September 2014, with ongoing winter monitoring being sponsored by California utility partners. Summer results show favorable system performance with extrapolated annual water heating savings of 1,466 to 2,300 kWh per year, based on the observed hot water loads. Additional summer space cooling benefits savings of 121 to 135 kWh per year were projected, further increasing the water heating savings by 5-9%. Given the project schedule for 2014 completion, no heating season impacts were able to be monitored.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Techno-Economic Analysis for a Potential Geothermal District Heating System in Tuttle, Oklahoma: Preprint

Geothermal deep direct use (DDU) has potential across a wide swath of the United States but is underutilized due to challenging project economics associated with developing a deep geothermal resource for a large-scale and variable heat demand. The National Renewable Energy Laboratory (NREL) and University of Oklahoma evaluated the feasibility of a geothermal district heating (GDH) and cooling system in two schools and 250 houses by utilizing existing oil and gas (O&G) wells in Tuttle, Oklahoma. Heating and cooling demand in the two schools and a typical single-family house were modeled using EnergyPlus building energy simulation software. The modeling results indicated that annual heating demand in two schools and 250 houses is approximately 2.61 GWhth, and cooling demand in the two schools is approximately 2.65 GWhth. In this scope, the techno-economic analysis (TEA) was conducted using the GEOPHIRES tool combined with the TOUGH2 reservoir simulator. The reservoir performance, including geothermal heat production capacity, was modeled by the reservoir simulator TOUGH2. Then, levelized cost of heat (LCOH) was calculated using GEOPHIRES version 3.0, which includes new features such as hourly heat load optimization and peak performance evaluation. Geothermal reservoir temperature was estimated as 90.5 degrees C at a total depth of 3.3 km by the regional average temperature gradient of 22.8 degrees C/km and validated by cation geothermometer calculations. Four production scenarios with two different well configurations and two different heat load profiles have been developed for well flow rates ranging between 3.1 kg/s and 9.3 kg/s. The LCOH of the district heating and cooling system was calculated between $95 and $210/MWh ($28/MMBtu to $62/MMBtu) for four different production scenarios. Typical natural gas prices for residential customers in Oklahoma have ranged from 9 to 19 $/MMBtu over the past decade, which indicates a challenge for deployment of such a GDH system.

deep direct-use↗

Study of the influence of heat sources on the out-of-pile calibration curve of calorimetric cells used for nuclear energy deposition quantification

At present the Jules Horowitz Reactor is under construction in Cadarache research center of CEA 'French Alternative Energies and Atomic Energy Commission' center located in the south-east of France. This new Material Testing Reactor (MTR) will be operational in late 2019 and will allow the generation of a new experimental potential (up to 20 irradiation devices simultaneously) and new harsh conditions such as higher neutron fluxes (5.10{sup 14} n.cm{sup -2}.s{sup -1} for E≥1 MeV), faster material ageing and higher nuclear heating (up to 20 W/g for nominal capacity of 100 MW). In nuclear research field, the control and the measurement of the nuclear heating (energy deposition rate per mass unit induced by the interactions of radiations with matter) is crucial to carry out accurate studies on ageing of materials and on the behavior of nuclear fuels under irradiation. Several experiments need to know precisely this key parameter in order to establish dedicated thermal conditions. The measurement of the nuclear heating inside MTRs is realized by three kinds of sensors: single-cell calorimeter, differential calorimeter and gamma thermometer. One scientific objective of the IN-CORE program, between CEA and Aix-Marseille University in 2009, is to improve the nuclear heating measurement. In this context a new multi-sensor device, called CARMEN, was made. This device contains in particular a differential calorimeter which was designed to measure the nuclear heating in the periphery of OSIRIS reactor (a MTR located at Saclay, France) up to 2 W/g and tested during two irradiation campaigns. Results obtained during these campaigns showed that temperatures reached inside the calorimeter are higher than ones obtained during the preliminary out-of-pile calibration experiments. For instance for 1.74 W/g, the in-pile temperature of the calorimeter rod is equal to 305 deg. C against 225 deg. C in laboratory conditions by simulating the nuclear heating by Joule Effect inside the calorimeter cell head. This discrepancy is higher than in previous experiments because the calorimeter owns a high sensitivity. Consequently, a new prototype was created and instrumented by other heat sources in order to impose an energy deposition on the calorimetric cell structure (in particular in the base) and to improve the calibration step in out-of-pile conditions. In this paper, on the first part a detailed description of the new calorimetric sensor will be given. On the second part, the experimental response of the sensor obtained for several internal heating conditions will be shown. The influence of these conditions on the calibration curve will be discussed. Then the response of this prototype will be also presented for different external cooling fluid conditions (in particular flow temperature). In this part, the comparison between the in-pile and out-of-pile experimental results will be performed. On the last part, these out-of-pile experiments will be completed by 2D axisymmetrical thermal simulations with the CEA code CAST3M using Finite Elements Method. After a comparison between experimental and numerical works, improvements of the sensor prototype will be studied (new heat sources). (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Techno-Economic Analysis for a Potential Geothermal District Heating System in Tuttle, Oklahoma

Geothermal deep direct use (DDU) has potential across a wide swath of the United States but is underutilized due to challenging project economics associated with developing a deep geothermal resource for a large-scale and variable heat demand. The National Renewable Energy Laboratory (NREL) and University of Oklahoma evaluated the feasibility of a geothermal district heating (GDH) and cooling system in two schools and 250 houses by utilizing existing oil and gas (O&G) wells in Tuttle, Oklahoma. Heating and cooling demand in the two schools and a typical single-family house were modeled using EnergyPlus building energy simulation software. The modeling results indicated that annual heating demand in two schools and 250 houses is approximately 2.61 GWhth, and cooling demand in the two schools is approximately 2.65 GWhth. In this scope, the techno-economic analysis (TEA) was conducted using the GEOPHIRES tool combined with the TOUGH2 reservoir simulator. The reservoir performance, including geothermal heat production capacity, was modeled by the reservoir simulator TOUGH2. Then, levelized cost of heat (LCOH) was calculated using GEOPHIRES version 3.0, which includes new features such as hourly heat load optimization and peak performance evaluation. Geothermal reservoir temperature was estimated as 90.5 degrees C at a total depth of 3.3 km by the regional average temperature gradient of 22.8 degrees C/km and validated by cation geothermometer calculations. Four production scenarios with two different well configurations and two different heat load profiles have been developed for well flow rates ranging between 3.1 kg/s and 9.3 kg/s. The LCOH of the district heating and cooling system was calculated between $95 and $210/MWh ($28/MMBtu to $62/MMBtu) for four different production scenarios. Typical natural gas prices for residential customers in Oklahoma have ranged from 9 to 19 $/MMBtu over the past decade, which indicates a challenge for deployment of such a GDH system.

deep direct-use↗

The process heat applications of HTGR in petroleum refining industry: adaptability and economy - 18425

High Temperature Gas Cooled Reactor (HTGR) is considered as a kind of potential heat producer for industry. Since the industrial heat utilization takes 60% of heat supply in China, the process heat of HTGR is more suitable for industrial manufacturing as high temperature heat source. In this article, the adaptabilities of HTGR for heat supply to petroleum refining industry are analyzed and it is found that the joint of process heat of HTGR and chemical industry is most predictable in the near future. For case study, technical and economic analysis of process heat-supply proposal in a typical refinery in China is finished and it is shown that though there is some technical and conceptual challenge, the application of process heat of HTGR in petroleum refining industry is feasible and competitive in economics. (authors)

02 PETROLEUM↗

TORCHE - Toolbox for Reactor Cross-Flow Heat Exchangers

As interest within the scientific community for the development of small modular reactors (SMRs) grows, utilizing compact and cross-flow heat exchangers present many design advantages. Cross-flow configurations of tube bundles allow water, liquid metal, or a molten salt to be contained within the tube side or shell side in an efficient spatial arrangement. The goal of this project is to provide the user with an easy-to-use set of tools for cross-flow heat exchanger design. The tools are intended to require little to no geometric set-up like meshing in a CFD code in order to enable rapid preliminary design and optimization. With this set of simple Python scripts, the user can determine the necessary quantities and correctional factors in order to assess the heat exchanger characteristics. The two characteristics used in designing novel and efficient heat exchangers incorporated into this work currently are pressure drop and heat transfer coefficients. In support of these efforts, the literature has been scoured for sources of experimental data and proposed methods for calculating pressure drop and heat transfer in cross-flow tube banks. Several empirical correlations and methodologies for calculating pressure drop and heat transfer incorporated into the Toolbox for Reactor Cross-Flow Heat Exchangers (TORCHE). TORCHE is an expansion on the cross-flow pressure drop scripts reported by Haefner et al.. Presented in this summary is a synopsis of the empirical correlations and methodologies of pressure drops and heat transfer coefficient. A validation effort of these models is also presented to provide confidence in the implementation. For this validation of TORCHE, experimental data has been gathered and extracted from graphs in the literature. Error bars were not reported in the experimental data used in this summary and therefore is not included in the analysis.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Finite element solution of MHD power-law fluid with slip velocity effect and non-uniform heat source/sink

The laminar steady boundary layer flow of an incompressible MHD Power-law fluid past a continuously moving surface is investigated numerically. The study involves the influence of surface slip and non-uniform heat source/sink on the flow and heat transfer. The governing boundary layer flow equations are transformed into non-dimensional, non-linear coupled ordinary differential equations with the help of suitable similarity transformations. The Galerkin finite element method is implemented to crack the resulting system. The impact of different involved physical parameters is exhibited on the dimensionless velocity profile, temperature distributions and rate of heat transfer in graphical and tabular forms for pseudoplastic and dilatant fluids. The local Nusselt number is found to be the decreasing function of slip parameter, temperature and space-dependent heat sink parameter whereas it increases with increasing values of temperature and space dependent heat source parameter. The problem has important application in attaining the sustainable heat transfer rate for the cooling of fluids, especially in heat exchangers used frequently in chemical industry, in order to increase the trustworthiness of a system, as it removes high heat loads from these systems.

97 MATHEMATICS AND COMPUTING↗

Refine your search to explore more results.