Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GAMMA FUNCTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Utility of DF-1 for Radioprotection in Lymphocytes

The development of degenerative changes in the vasculature, such as atherosclerosis, is a known consequence of exposure to ionizing radiation, and is thus a concern for astronaut health following long duration space flight. Cellular damage caused by radiation is due to free radical generation and DNA damage. The goal of this project was to assess the ability of a C60-derivative, DF-1, to mitigate cellular damage resulting from radiation exposure in primary human lymphocytes. DF-1 is a water-soluble C60 fullerene encapsulated in dendrimeric functional groups that is proposed to exhibit antioxidant properties. Human lymphocytes are radiosensitive and travel throughout the body potentially causing bystander effects in any tissues they contact. These cells were subjected to varying doses of gamma radiation in the presence or absence of DF-1. Cells were collected at 48 hours post-irradiation for chromosomal aberration studies and at 72 hours post-irradiation for micronuclei studies. These studies showed that the irradiated cells contained more chromosomal aberrations and micronuclei than the control cells. Addition of the DF-1 reduced the amount of observed DNA damage in the irradiated cells. Growth curves were measured for the lymphocytes exposed to 0 and 4 Gray gamma irradiations, and we observed less growth in the cells irradiated at 4 Gy. 2,7-dichlorofluorescein diacetate was used to detect reactive oxygen species production, and increased production of ROS was observed in the irradiated lymphocytes. Human lymphocytes were subjected to varying doses of gamma or photon radiation in the presence and absence of DF-1 and a known radioprotectant, amifostine. After irradiation, the production of reactive oxygen species, growth curves and cell viability were measured. These cells were also collected to quantify chromosomal aberrations and micronuclei formation. We predict that irradiated cells will show the most damage and that DF-1 will provide protective effects similar to those of amifostine, an established radioprotectant.

Reynolds, Julia↗

Changes in Liver Metabolic Gene Expression from Radiation Exposure

Increased exposure to radiation is one physiological stressor associated with spaceflight. While known to alter normal physiological function, how radiation affects metabolism of administered medications is unclear. Crew health could be affected if the actions of medications used in spaceflight deviated from expectations formed during terrestrial medication use. Three different doses of gamma radiation (50 mGy - 6.05 Gy) and a sham were administered to groups of 6 mice each, and after various intervals of recovery time, liver gene expression was measured with RT-qPCR arrays for drug metabolism and DNA repair enzymes. Results indicated approx.65 genes of the 190 tested were significantly affected by at least one of the radiation doses. Many of the affected genes are involved in the metabolism of drugs with hydrophobic or steroid-like structures, maintenance of redox homeostasis and repair of DNA damage. Most affected genes returned to near control expression levels by 7 days post-treatment. With 6 Gy exposure, metallothionein expression was 132-fold more than control at the 4 hr time point, and fell at each later time point (11-fold at 24 hrs, and 8-fold at 7 days). In contrast, Cyp17a1 showed a 4-fold elevation at 4 hrs after exposure and remained constant for 7 days.

Peters, C. P.↗

The electron injection spectrum determined by anomalous excesses in cosmic ray, gamma ray, and microwave data

Recent cosmic ray, gamma ray, and microwave signals observed by Fermi, PAMELA, and WMAP indicate an unexpected primary source of e{sup +}e{sup -} at 10-1000 GeV. We fit these data to 'standard backgrounds' plus a new source, assumed to be a separable function of position and energy. For the spatial part, we consider three cases: annihilating dark matter, decaying dark matter, and pulsars. In each case, we use GALPROP to inject energy in log-spaced energy bins and compute the expected cosmic ray and photon signals for each bin. We then fit a linear combination of energy bins, plus backgrounds, to the data. We use a nonparametric fit, with no prior constraints on the spectrum except smoothness and non-negativity. In addition, we consider arbitrary modifications to the energy spectrum of the ordinary primary source function, fixing its spatial part, finding this alone to be inadequate to explain the PAMELA or WMAP signals. We explore variations in the fits due to choice of magnetic field, primary electron injection index, spatial profiles, propagation parameters, and fit regularization method. Dark matter annihilation fits well, where our fit finds a mass of {approx}1 TeV and a boost factor times energy fraction of {approx}70. While it is possible for dark matter decay and pulsars to fit the data, unconventionally high magnetic fields and radiation densities are required near the Galactic center to counter the relative shallowness of the assumed spatial profiles. We also fit to linear combinations of these three scenarios, though the fit is much less constrained.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Depletion of Securin Induces Senescence After Irradiation and Enhances Radiosensitivity in Human Cancer Cells Regardless of Functional p53 Expression

Purpose: Radiotherapy is one of the best choices for cancer treatment. However, various tumor cells exhibit resistance to irradiation-induced apoptosis. The development of new strategies to trigger cancer cell death besides apoptosis is necessary. This study investigated the role of securin in radiation-induced apoptosis and senescence in human cancer cells. Methods and Materials: Cell survival was determined using clonogenic assays. Western blot analysis was used to analyze levels of securin, caspase-3, PARP, p53, p21, Rb, gamma-H2AX, and phospho-Chk2. Senescent cells were analyzed using a beta-galactosidase staining assay. A securin-expressed vector (pcDNA-securin) was stably transfected into securin-null HCT116 cells. Securin gene knockdown was performed by small interfering RNA and small hairpin RNA in HCT116 and MDA-MB-231 cells, respectively. Results: Radiation was found to induce apoptosis in securin wild type HCT116 cells but induced senescence in securin-null cells. Restoration of securin reduced senescence and increased cell survival in securin-null HCT116 cells after irradiation. Radiation-induced gamma-H2AX and Chk2 phosphorylation were induced transiently in securin-wild-type cells but exhibited sustained activation in securin-null cells. Securin gene knockdown switches irradiation-induced apoptosis to senescence in both HCT116 p53-null and MDA-MB-231 cells. Conclusions: Our results demonstrated that the level of securin expression plays a determining role in the radiosensitivity and fate of cells. Depletion of securin impairs DNA repair after irradiation, increasing DNA damage and promoting senescence in the residual surviving cells regardless of functional p53 expression. The knockdown of securin may contribute to a novel radiotherapy protocol for the treatment of human cancer cells that are resistant to irradiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Performance parameters of a liquid filled ionization chamber array

Purpose: In this work, the properties of the two-dimensional liquid filled ionization chamber array Octavius 1000SRS (PTW-Freiburg, Germany) for use in clinical photon-beam dosimetry are investigated.Methods: Measurements were carried out at an Elekta Synergy and Siemens Primus accelerator. For measurements of stability, linearity, and saturation effects of the 1000SRS array a Semiflex 31013 ionization chamber (PTW-Freiburg, Germany) was used as a reference. The effective point of measurement was determined by TPR measurements of the array in comparison with a Roos chamber (type 31004, PTW-Freiburg, Germany). The response of the array with varying field size and depth of measurement was evaluated using a Semiflex 31010 ionization chamber as a reference. Output factor measurements were carried out with a Semiflex 31010 ionization chamber, a diode (type 60012, PTW-Freiburg, Germany), and the detector array under investigation. The dose response function for a single detector of the array was determined by measuring 1 cm wide slit-beam dose profiles and comparing them against diode-measured profiles. Theoretical aspects of the low pass properties and of the sampling frequency of the detector array were evaluated. Dose profiles measured with the array and the diode detector were compared, and an intensity modulated radiation therapy (IMRT) field was verified using the Gamma-Index method and the visualization of line dose profiles.Results: The array showed a short and long term stability better than 0.1% and 0.2%, respectively. Fluctuations in linearity were found to be within ±0.2% for the vendor specified dose range. Saturation effects were found to be similar to those reported in other studies for liquid-filled ionization chambers. The detector's relative response varied with field size and depth of measurement, showing a small energy dependence accounting for maximum signal deviations of ±2.6% from the reference condition for the setup used. The σ-values of the Gaussian dose response function for a single detector of the array were found to be (0.72 ± 0.25) mm at 6 MV and (0.74 ± 0.25) mm at 15 MV and the corresponding low pass cutoff frequencies are 0.22 and 0.21 mm{sup −1}, respectively. For the inner 5 × 5 cm{sup 2} region and the outer 11 × 11 cm{sup 2} region of the array the Nyquist theorem is fulfilled for maximum sampling frequencies of 0.2 and 0.1 mm{sup −1}, respectively. An IMRT field verification with a Gamma-Index analysis yielded a passing rate of 95.2% for a 3 mm/3% criterion with a TPS calculation as reference.Conclusions: This study shows the applicability of the Octavius 1000SRS in modern dosimetry. Output factor and dose profile measurements illustrated the applicability of the array in small field and stereotactic dosimetry. The high spatial resolution ensures adequate measurements of dose profiles in regular and intensity modulated photon-beam fields.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Observation of the Crab Nebula with the HAWC Gamma-Ray Observatory

The Crab Nebula is the brightest TeV gamma-ray source in the sky and has been used for the past 25 years as a reference source in TeV astronomy, for calibration and verification of new TeV instruments. The High Altitude Water Cherenkov Observatory (HAWC), completed in early 2015, has been used to observe the Crab Nebula at high significance across nearly the full spectrum of energies to which HAWC is sensitive. HAWC is unique for its wide field of view, nearly 2 sr at any instant, and its high-energy reach, up to 100 TeV. HAWC’s sensitivity improves with the gamma-ray energy. Above ∼1 TeV the sensitivity is driven by the best background rejection and angular resolution ever achieved for a wide-field ground array. We present a time-integrated analysis of the Crab using 507 live days of HAWC data from 2014 November to 2016 June. The spectrum of the Crab is fit to a function of the form ϕ(E)=ϕ{sub 0}(E/E{sub 0}){sup −α−β⋅ln(E/E{sub 0})}. The data is well fitted with values of α = 2.63 ± 0.03, β = 0.15 ± 0.03, and log{sub 10}(ϕ{sub 0} cm{sup 2} s TeV)=−12.60±0.02 when E {sub 0} is fixed at 7 TeV and the fit applies between 1 and 37 TeV. Study of the systematic errors in this HAWC measurement is discussed and estimated to be ±50% in the photon flux between 1 and 37 TeV. Confirmation of the Crab flux serves to establish the HAWC instrument’s sensitivity for surveys of the sky. The HAWC all-sky survey will be the deepest survey of the northern sky ever conducted in the multi-TeV band.

79 ASTRONOMY AND ASTROPHYSICS↗

Signs of magnetic acceleration and multizone emission in GRB 080825C

One of the major results from the study of gamma-ray bursts with the Fermi Gamma-ray Space Telescope has been the confirmation that several emission components can be present in the energy spectrum. In this paper, we reanalyse the spectrum of GRB 080825C using data from the Fermi-Large Area Telescope (LAT) and Gamma-ray Burst Monitor instruments. Although fairly weak, it is the first gamma-ray burst detected by the Fermi-LAT. We improve on the original analysis by using the LAT Low Energy events covering the 30–100 MeV band. We find evidence of an additional component above the main emission peak (modelled using a Band function) with a significance of 3.5σ in two out of the four time bins. The component is well fitted by a Planck function, but shows unusual behaviour: the peak energy increases in the prompt emission phase, reaching energies of several MeV. This is the first time such a trend has been seen, and implies that the origin of this component is different from those previously detected. We suggest that the two spectral components likely arise in different regions of the outflow, and that strong constraints can be achieved by assuming one of them originates from the photosphere. Finally, the most promising model appears to be that the high-energy peak is the result of photospheric emission in a Poynting flux dominated outflow where the magnetization increases with time.

79 ASTRONOMY AND ASTROPHYSICS↗

Equipartition gamma-ray blazars and the location of the gamma-ray emission site in 3C 279

Blazar spectral models generally have numerous unconstrained parameters, leading to ambiguous values for physical properties like Doppler factor δ{sub D} or fluid magnetic field B'. To help remedy this problem, a few modifications of the standard leptonic blazar jet scenario are considered. First, a log-parabola function for the electron distribution is used. Second, analytic expressions relating energy loss and kinematics to blazar luminosity and variability, written in terms of equipartition parameters, imply δ{sub D}, B', and the peak electron Lorentz factor γ{sub pk}{sup ′}. The external radiation field in a blazar is approximated by Lyα radiation from the broad-line region (BLR) and ≈0.1 eV infrared radiation from a dusty torus. When used to model 3C 279 spectral energy distributions from 2008 and 2009 reported by Hayashida et al., we derive δ{sub D} ∼ 20-30, B' ∼ few G, and total (IR + BLR) external radiation field energy densities u ∼ 10{sup –2}-10{sup –3} erg cm{sup –3}, implying an origin of the γ-ray emission site in 3C 279 at the outer edges of the BLR. This is consistent with the γ-ray emission site being located at a distance R ≲ Γ{sup 2} ct {sub var} ∼ 0.1(Γ/30){sup 2}(t {sub var}/10{sup 4} s) pc from the black hole powering 3C 279's jets, where t {sub var} is the variability timescale of the radiation in the source frame, and at farther distances for narrow-jet and magnetic-reconnection models. Excess ≳ 5 GeV γ-ray emission observed with Fermi LAT from 3C 279 challenges the model, opening the possibility of a second leptonic component or a hadronic origin of the emission. For low hadronic content, absolute jet powers of ≈10% of the Eddington luminosity are calculated.

79 ASTRONOMY AND ASTROPHYSICS↗

Gamma-Ray Simulated Spectrum Deconvolution of a LaBr₃ 1-in. x 1-in. Scintillator for Nondestructive ATR Fuel Burnup On-Site Predictions

A deconvolution method for a LaBr₃ 1"x1" detector for nondestructive Advanced Test Reactor (ATR) fuel burnup applications was developed. The method consisted of obtaining the detector response function, applying a deconvolution algorithm to 1”x1” LaBr₃ simulated, data along with evaluating the effects that deconvolution have on nondestructively determining ATR fuel burnup. The simulated response function of the detector was obtained using MCNPX as well with experimental data. The Maximum-Likelihood Expectation Maximization (MLEM) deconvolution algorithm was selected to enhance one-isotope source-simulated and fuel- simulated spectra. The final evaluation of the study consisted of measuring the performance of the fuel burnup calibration curve for the convoluted and deconvoluted cases. The methodology was developed in order to help design a reliable, high resolution, rugged and robust detection system for the ATR fuel canal capable of collecting high performance data for model validation, along with a system that can calculate burnup and using experimental scintillator detector data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of the Forward-Backward Charge Asymmetry($A_{FB}$) using $p\bar{p}\rightarrow Z/\gamma*\rightarrow e^+e^-$ events in $\sqrt{S} = 1.96$ TeV

This dissertation describes a measurement of the forward-backward asymmetry(A FB ) in p$\bar{p}$ → Z/γ* → ee events using 5.0 fb -1 data collected by the D0 detector at the Fermilab Tevatron. The AFB is measured as a function of the invariant mass of the electron-positron pair. Along with obtaining normalized differential cross section 1/σ x dσ/dM and Z to light quark couplings, we measured the Standard Model(SM) fundamental parameter, the effective weak mixing angle sin 2 θ$lept\atop{eff}$, with an unprecedented precise in light quark sector, namely the single D0 measurement has surpassed the LEP combination of four experiment results of inclusive hadronic charge asymmetry.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Results for aliovalent doping of CeBr{sub 3} with Ca{sup 2+}

Despite the outstanding scintillation performance characteristics of cerium tribromide (CeBr{sub 3}) and cerium-activated lanthanum tribromide, their commercial availability and application are limited due to the difficulties of growing large, crack-free single crystals from these fragile materials. This investigation employed aliovalent doping to increase crystal strength while maintaining the optical properties of the crystal. One divalent dopant (Ca{sup 2+}) was used as a dopant to strengthen CeBr{sub 3} without negatively impacting scintillation performance. Ingots containing nominal concentrations of 1.9% of the Ca{sup 2+} dopant were grown, i.e., 1.9% of the CeBr{sub 3} molecules were replaced by CaBr{sub 2} molecules, to match our target replacement of 1 out of 54 cerium atoms be replaced by a calcium atom. Precisely the mixture was composed of 2.26 g of CaBr{sub 2} added to 222.14 g of CeBr{sub 3}. Preliminary scintillation measurements are presented for this aliovalently doped scintillator. Ca{sup 2+}-doped CeBr{sub 3} exhibited little or no change in the peak fluorescence emission for 371 nm optical excitation for CeBr{sub 3}. The structural, electronic, and optical properties of CeBr{sub 3} crystals were studied using the density functional theory within the generalized gradient approximation. Calculated lattice parameters are in agreement with the experimental data. The energy band structures and density of states were obtained. The optical properties of CeBr{sub 3}, including the dielectric function, were calculated.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The DNA glycosylases OGG1 and NEIL3 influence differentiation potential, proliferation, and senescence-associated signs in neural stem cells

Highlights: Black-Right-Pointing-Pointer DNA glycosylases OGG1 and NEIL3 are required for neural stem cell state. Black-Right-Pointing-Pointer No effect on cell viability by OGG1 or NEIL3 knockdown in neural stem cells. Black-Right-Pointing-Pointer OGG1 or NEIL3 RNA knockdown result in decreased proliferation and differentiation. Black-Right-Pointing-Pointer Increased HP1{gamma} immunoreactivity after NEIL3 knockdown suggests premature senescence. -- Abstract: Embryonic neural stem cells (NSCs) exhibit self-renewal and multipotency as intrinsic characteristics that are key parameters for proper brain development. When cells are challenged by oxidative stress agents the resulting DNA lesions are repaired by DNA glycosylases through the base excision repair (BER) pathway as a means to maintain the fidelity of the genome, and thus, proper cellular characteristics. The functional roles for DNA glycosylases in NSCs have however remained largely unexplored. Here we demonstrate that RNA knockdown of the DNA glycosylases OGG1 and NEIL3 decreased NSC differentiation ability and resulted in decreased expression of both neuronal and astrocytic genes after mitogen withdrawal, as well as the stem cell marker Musashi-1. Furthermore, while cell survival remained unaffected, NEIL3 deficient cells displayed decreased cell proliferation rates along with an increase in HP1{gamma} immunoreactivity, a sign of premature senescence. Our results suggest that DNA glycosylases play multiple roles in governing essential neural stem cell characteristics.

60 APPLIED LIFE SCIENCES↗

A2111: A z= 0.23 Butcher-Oemler Cluster with a Non-Isothermal Atmosphere and Normal Metallicity

We report results from an x-ray spectral study of the z=0.23 Abell 2111 galaxy cluster using the Advanced Satellite for Astrophysics and Cosmology and the ROSAT Position Sensitive Proportional Counter. By correcting for the energy-dependent point-spread function of the instruments, we have examined the temperature structure of the cluster. The cluster's core within 3 is found to have a temperature of 5.4 +/- 0.5 keV, significantly higher than 2.8 +/-0.7 keV in the surrounding region of r = 3-6. This radially decreasing temperature structure can be parameterized by a polytropic index of gamma less than 1.4. Furthermore, the intracluster medium appears clumpy on scales less than 1. Early studies have revealed that the x-ray centroid of the cluster shifts with spatial scale and the overall optical and x-ray morphology is strongly elongated. These results together suggest that A2111 in undergoing a merger, which is likely responsible for the high fraction of blue galaxies observed in the cluster. We have further measured the abundance of the medium as 0.25 +/- 0.14 solar. This value is similar to those of nearby clusters which do not show a large blue galaxy function, suggesting that star formation in disk galaxies and subsequent loss to the intracluster medium do not drastically alter the average abundance of a cluster since z=0.23.

Wang, Q. Daniel↗

Implementation of EPID transit dosimetry based on a through-air dosimetry algorithm

Purpose: A method to perform transit dosimetry with an electronic portal imaging device (EPID) by extending the commercial implementation of a published through-air portal dose image (PDI) prediction algorithm Van Esch et al.[Radiother. Oncol. 71, 223-234 (2004)] is proposed and validated. A detailed characterization of the attenuation, scattering, and EPID response behind objects in the beam path is used to convert through-air PDIs into transit PDIs. Methods: The EPID detector response beyond a range of water equivalent thicknesses (0-35 cm) and field sizes (3x3 to 22.2x29.6 cm{sup 2}) was analyzed. A constant air gap between the phantom exit surface and the EPID was utilized. A model was constructed that accounts for the beam's attenuation along the central axis, the presence of phantom scattered radiation, the detector's energy dependent response, and the difference in EPID off-axis pixel response relative to the central pixel. The efficacy of the algorithm was verified by comparing predicted and measured PDIs for IMRT fields delivered through phantoms of increasing complexity. Results: The expression that converts a through-air PDI to a transit PDI is dependent on the object's thickness, the irradiated field size, and the EPID pixel position. Monte Carlo derived narrow-beam linear attenuation coefficients are used to model the decrease in primary fluence incident upon the EPID due to the object's presence in the beam. This term is multiplied by a factor that accounts for the broad beam scatter geometry of the linac-phantom-EPID system and the detector's response to the incident beam quality. A 2D Gaussian function that models the nonuniformity of pixel response across the EPID detector plane is developed. For algorithmic verification, 49 IMRT fields were repeatedly delivered to homogeneous slab phantoms in 5 cm increments. Over the entire set of measurements, the average area passing a 3%/3mm gamma criteria slowly decreased from 98% for no material in the beam to 96.7% for 35 cm of material in the beam. The same 49 fields were delivered to a heterogeneous slab phantom and on average, 97.1% of the pixels passed the gamma criteria. Finally, a total of 33 IMRT fields were delivered to the anthropomorphic phantom and on average, 98.1% of the pixels passed. The likelihood of good matches was independent of anatomical site. Conclusions: A prediction of the transit PDI behind a phantom or patient can be created for the purposes of treatment verification via an extension of the Van Esch through-air PDI algorithm. The results of the verification measurements through phantoms indicate that further investigation through patients during their treatments is warranted.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coded-aperture imaging in nuclear medicine

Coded-aperture imaging is a technique for imaging sources that emit high-energy radiation. This type of imaging involves shadow casting and not reflection or refraction. High-energy sources exist in x ray and gamma-ray astronomy, nuclear reactor fuel-rod imaging, and nuclear medicine. Of these three areas nuclear medicine is perhaps the most challenging because of the limited amount of radiation available and because a three-dimensional source distribution is to be determined. In nuclear medicine a radioactive pharmaceutical is administered to a patient. The pharmaceutical is designed to be taken up by a particular organ of interest, and its distribution provides clinical information about the function of the organ, or the presence of lesions within the organ. This distribution is determined from spatial measurements of the radiation emitted by the radiopharmaceutical. The principles of imaging radiopharmaceutical distributions with coded apertures are reviewed. Included is a discussion of linear shift-variant projection operators and the associated inverse problem. A system developed at the University of Arizona in Tucson consisting of small modular gamma-ray cameras fitted with coded apertures is described.

Smith, Warren E.↗

AdS Black Disk Model for Small-x Deep Inelastic Scattering

Using the approximate conformal invariance of QCD at high energies we consider a simple anti-de Sitter black disk model to describe saturation in deep inelastic scattering. Deep inside saturation the structure functions have the same power law scaling, F{sub T}{approx}F{sub L}{approx}x{sup -{omega}}, where {omega} is related to the expansion rate of the black disk with energy. Furthermore, the ratio F{sub L}/F{sub T} is given by the universal value (1+{omega}/3+{omega}), independently of the target. For {gamma}*-{gamma}* scattering at high energies we obtain explicit expressions and ratios for the total cross sections of transverse and longitudinal photons in terms of the single parameter {omega}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Finding A Minimally Informative Dirichlet Prior Using Least Squares

In a Bayesian framework, the Dirichlet distribution is the conjugate distribution to the multinomial likelihood function, and so the analyst is required to develop a Dirichlet prior that incorporates available information. However, as it is a multiparameter distribution, choosing the Dirichlet parameters is less straightforward than choosing a prior distribution for a single parameter, such as p in the binomial distribution. In particular, one may wish to incorporate limited information into the prior, resulting in a minimally informative prior distribution that is responsive to updates with sparse data. In the case of binomial p or Poisson \lambda, the principle of maximum entropy can be employed to obtain a so-called constrained noninformative prior. However, even in the case of p, such a distribution cannot be written down in the form of a standard distribution (e.g., beta, gamma), and so a beta distribution is used as an approximation in the case of p. In the case of the multinomial model with parametric constraints, the approach of maximum entropy does not appear tractable. This paper presents an alternative approach, based on constrained minimization of a least-squares objective function, which leads to a minimally informative Dirichlet prior distribution. The alpha-factor model for common-cause failure, which is widely used in the United States, is the motivation for this approach, and is used to illustrate the method. In this approach to modeling common-cause failure, the alpha-factors, which are the parameters in the underlying multinomial model for common-cause failure, must be estimated from data that are often quite sparse, because common-cause failures tend to be rare, especially failures of more than two or three components, and so a prior distribution that is responsive to updates with sparse data is needed.

99 GENERAL AND MISCELLANEOUS↗

Refine your search to explore more results.