At least 1,801 records · Page 100

A Deep Neural Network for Simultaneous Estimation of b Jet Energy and Resolution

We describe a method to obtain point and dispersion estimates for the energies of jets arising from b quarks produced in proton–proton collisions at an energy of $\sqrt{s}=13\,\text {TeV} $ at the CERN LHC. The algorithm is trained on a large sample of simulated b jets and validated on data recorded by the CMS detector in 2017 corresponding to an integrated luminosity of 41 $\,\text {fb}^{-1}$. A multivariate regression algorithm based on a deep feed-forward neural network employs jet composition and shape information, and the properties of reconstructed secondary vertices associated with the jet. The results of the algorithm are used to improve the sensitivity of analyses that make use of b jets in the final state, such as the observation of Higgs boson decay to $\hbox {b}\bar{\hbox {b}}$.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Variable-angle high-angle annular dark-field imaging: application to three-dimensional dopant atom profiling

Variable-angle high-angle annular dark-field (HAADF) imaging in scanning transmission electron microscopy is developed for precise and accurate determination of three-dimensional (3D) dopant atom configurations. Gd-doped SrTiO3 films containing Sr columns containing zero, one, or two Gd dopant atoms are imaged in HAADF mode using two different collection angles. Variable-angle HAADF significantly increases both the precision and accuracy of 3D dopant profiling. Using image simulations, it is shown that the combined information from the two detectors reduces the uncertainty in the dopant depth position measurement and can uniquely identify certain atomic configurations that are indistinguishable with a single detector setting. Additional advances and applications are discussed.

Science & Technology - Other Topics↗

Multipurpose furnace for in situ studies of polycrystalline materials using synchrotron radiation

We report a multipurpose furnace designed for studies using synchrotron radiation on polycrystalline materials, namely, metals, ceramics, and (semi)crystalline polymers. The furnace has been designed to carry out three-dimensional (3D) x-ray diffraction measurements but can also be used for other types of synchrotron radiation research. The furnace has a very low thermal gradient across the specimen (<0.2 degree sign C/mm). Accurate determination of the temperature can be carried out by welding a thermocouple to the specimen. The furnace can be rotated over an angle of 90 degree sign in order to determine the crystallographic orientation of each individual grain. It is possible to follow growth kinetics of all grains in the illuminated volume of the specimen. The specimen environment can be controlled varying from vacuum (up to 10{sup -5} mbar) to gas or air filled. The maximum temperature of operation is 1500 degree sign C, with the possibility of achieving high heating (up to 20 deg. C/s) and cooling rates (up to 30 deg. C/s without quenching gas). 3D maps of the microstructure of the specimen can be generated at elevated temperatures by bringing the high-resolution detector close to the specimen. We show an example of a simulation of the heat affected zone during the thermal cycle of a weld in a transformation-induced plasticity steel carried out using the furnace. The unique characteristics of the furnace open possibility of new fields in materials research using synchrotron radiation.

36 MATERIALS SCIENCE↗

Temperature trends and correlation between SQUID superparamagnetic relaxometry and dc-magnetization on model iron-oxide nanoparticles

Structural properties of iron-oxide nanoparticles deeply affect their magnetic performance in many applications such as with superparamagnetic relaxometry, when employed as cell-targeted magnetic nanoparticles for in vivo diagnostics. In this work, we present a detailed characterization of model nanoparticles for this application, with an average size of ~25 nm and a narrow size dispersion (σ < 7%). Considering the intrinsic structural properties of these model nanoparticles, the study of temperature dependence and correlation between dc-magnetization and superconducting quantum interference detector-relaxometry are discussed based on known theoretical predictions and computer simulations of the magnetic dipole moment and characteristic decay constants. Furthermore, computer simulations provide support in clarifying how important the overall collective magnetization is affected by particle size dispersion, which has a direct role on sustaining the magnetic relaxation signal in the temperature range required in preclinical and clinical settings.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Elastic depths for detecting shape anomalies in functional data

This this paper, we propose a new family of depth measures called the elastic depths that can be used to greatly improve shape anomaly detection in functional data. Shape anomalies are functions that have considerably different geometric forms or features from the rest of the data. Identifying them is generally more difficult than identifying magnitude anomalies because shape anomalies are often not distinguishable from the bulk of the data with visualization methods. The proposed elastic depths use the recently developed elastic distances to directly measure the centrality of functions in the amplitude and phase spaces. Measuring shape outlyingness in these spaces provides a rigorous quantification of shape which, in turn, gives the elastic depths a strong theoretical and practical advantage over other methods in detecting shape anomalies. A simple boxplot and thresholding method are introduced to identify shape anomalies using the elastic depths. We assess the elastic depth's detection skill on simulated shape outlier scenarios and compare them against popular shape anomaly detectors. Finally, bond yields, image outlines, and hurricane trajectories are used to demonstrate our method's applicability to functional data observed on three different manifolds.

97 MATHEMATICS AND COMPUTING↗

Practical considerations for measuring global spin density matrix elements of vector mesons in heavy-ion collisions

The STAR Collaboration has reported a significant 𝜙-meson global spin alignment (𝜌 00 ) signal in Au+Au collisions at $\sqrt{s_{NN}}$ ≤ 62 GeV by measuring the polar angle distribution of 𝜙-meson daughters with respect to the orbital angular momentum direction of the collision system. Here, in this paper, a new method is explored for studying vector-meson global spin alignment in heavy-ion collisions by examining the two-dimensional (2D) polar and azimuthal angle distribution. This method allows simultaneous extraction of 𝜌 00 and off-diagonal spin density matrix elements (SDMEs), providing unique access to local quark-antiquark spin correlations and spin hydrodynamics in quark-gluon plasma. The new 2D method also removes potential biases from nonzero off-diagonal SDMEs on 𝜌 00 with the 1D method. A detailed procedure to correct for detector acceptance and resolution effects is also presented and validated by simulation studies.

Wilks, Gavin [University of Illinois, Chicago, IL ↗

Characterizing a supernova’s standing accretion shock instability with neutrinos and gravitational waves

Here, we perform a novel multi-messenger analysis for the identification and parameter estimation of the Standing Accretion Shock Instability (SASI) in a core collapse supernova with neutrino and gravitational wave (GW) signals. In the neutrino channel, this method performs a likelihood ratio test for the presence of SASI in the frequency domain. For gravitational wave signals we process an event with a modified constrained likelihood method. Using simulated supernova signals, the properties of the Hyper-Kamiokande neutrino detector, and O3 LIGO Interferometric data, we produce the two-dimensional probability density distribution (PDF) of the SASI activity indicator and calculate the probability of detection P D as well as the false identification probability P FI . We discuss the probability to establish the presence of the SASI as a function of the source distance in each observational channel, as well as jointly. Compared to a single-messenger approach, the joint analysis results in P D (at P FI = 0.1) of SASI activities that is larger by up to ≈ 40% for a distance to the supernova of 5 kpc. We also discuss how accurately the frequency and duration of the SASI activity can be estimated in each channel separately. Our methodology is suitable for implementation in a realistic data analysis and a multi-messenger setting.

79 ASTRONOMY AND ASTROPHYSICS↗

Beam-dynamics driven design of the LHeC energy-recovery linac

The LHeC study is a possible upgrade of the LHC that aims at delivering an electron beam for collisions with the existing hadronic beams. The current baseline design for the electron facility consists of a multi-pass superconducting energy-recovery linac operating in a continuous wave mode. Here, we summarize the overall layout of such ERL complex located on the LHC site and introduce the most recent developments. We review of the lattice components, presenting their baseline design along with possible alternatives that aims at improving the overall machine performance. The detector bypass has been designed and integrated into the lattice. Tracking simulations allowed us to verify the high current (~150 mA in the linacs) beam operation required for the LHeC to serve as an Higgs Factory. The impact of single and multi-bunch wake-fields, synchrotron radiation and beam-beam effects has been assessed in this paper.

43 PARTICLE ACCELERATORS↗

Boron-10 Lined Proportional Counter Model Validation

The decreasing supply of 3He is stimulating a search for alternative neutron detectors; one potential 3He replacement is 10B-lined proportional counters. Simulations are being performed to predict the performance of systems designed with 10B-lined tubes. Boron-10-lined tubes are challenging to model accurately because the neutron capture material is not the same as the signal generating material. Thus, to simulate the efficiency, the neutron capture reaction products that escape the lining and enter the signal generating fill gas must be tracked. The tube lining thickness and composition are typically proprietary vendor information, and therefore add additional variables to the system simulation. The modeling methodologies used to predict the neutron detection efficiency of 10B-lined proportional counters were validated by comparing simulated to measured results. The measurements were made with a 252Cf source positioned at several distances from a moderated 2.54-cm diameter 10B-lined tube. Models were constructed of the experimental configurations using the Monte Carlo transport code MCNPX, which is capable of tracking the reaction products from the (n,10B) reaction. Several different lining thicknesses and compositions were simulated for comparison with the measured data. This paper presents the results of the evaluation of the experimental and simulated data, and a summary of how the different linings affect the performance of a coincidence counter configuration designed with 10B-lined proportional counters.

Lintereur, Azaree T.↗

A Comparison of Adaptive and Template Matching Techniques for Radio-Isotope Identification

We compare and contrast the effectiveness of a set of adaptive and non-adaptive algorithms for isotope identi cation based on gamma-ray spectra. One dimensional energy spectra are simulated for a variety of dwell-times and source to detector distances in order to reflect conditions typically encountered in radiological emergency response and environmental monitoring applications. We nd that adaptive methods are more accurate and computationally efficient than non-adaptive in cases of operational interest.

97 MATHEMATICS AND COMPUTING↗

SU-E-T-293: Dosimetric Analysis of Microscopic Disease in SBRT for Lung Cancers

Purpose: To evaluate the dosimetry of microscopic disease (MD) region of lung cancer in stereotactic body radiation therapy (SBRT). Methods: For simplicity, we assume organ moves along one dimension. The probability distribution function of tumor position was calculated according to the breathing cycle. The dose to the MD region was obtained through accumulating the treatment planning system calculated doses at different positions in a breathing cycle. A phantom experiment was then conducted to validate the calculated results using a motion phantom (The CIRS ‘Dynamic’ Thorax Phantom). The simulated breathing pattern used a cos4(x) curve with an amplitude of 10mm. A 3-D conformal 7-field plan with 6X energy was created and the dose was calculated in the average intensity projection (AIP) simulation CT images. Both films (EBT2) and optically stimulated luminescence (OSL) detectors were inserted in the target of the phantom to measure the dose during radiation delivery (Varian Truebeam) and results were compared to planning dose parameters. Results: The Gamma analysis (3%/3mm) between measured dose using EBT2 film and calculated dose using AIP was 80.5%, indicating substantial dosimetric differences. While the Gamma analysis (3%/3mm) between measured dose using EBT2 and accumulated dose using 4D-CT was 98.9%, indicating the necessity of dose accumulation using 4D-CT. The measured doses using OSL and theoretically calculated doses using probability distribution function at the corresponding position were comparable. Conclusion: Use of static dose calculation in the treatment planning system could substantially underestimate the actually delivered dose in the MD region for a moving target. Funding Supported by NSFC, No.81372436.

60 APPLIED LIFE SCIENCES↗

SU-G-IeP3-10: Molecular Imaging with Clinical X-Ray Sources and Compton Cameras

Purpose: The application of Compton cameras (CC) is a novel approach translating XFCT to a practical modality realized with clinical CT systems without the restriction of pencil beams. The dual modality design offers additional information without extra patient dose. The purpose of this work is to investigate the feasibility and efficacy of using CCs for volumetric x-ray fluorescence (XF) imaging by Monte Carlo (MC) simulations and statistical image reconstruction. Methods: The feasibility of a CC for imaging x-ray fluorescence emitted from targeted lesions is examined by MC simulations. 3 mm diameter water spheres with various gold concentrations and detector distances are placed inside the lung of an adult human phantom (MIRD) and are irradiated with both fan and cone-beam geometries. A sandwich design CC composed of Silicon and CdTe is used to image the gold nanoparticle distribution. The detection system comprises four 16×26 cm{sup 2} detector panels placed on the chest of a MIRD phantom. Constraints of energy-, spatial-resolution, clinical geometries and Doppler broadening are taken into account. Image reconstruction is performed with a list-mode MLEM algorithm with cone-projector on a GPU. Results: The comparison of reconstruction of cone- and fan-beam excitation shows that the spatial resolution is improved by 23% for fan-beams with significantly decreased processing time. Cone-beam excitation increases scatter content disturbing quantification of lesions near the body surface. Spatial resolution and detectability limit in the center of the lung is 8.7 mm and 20 fM for 50 nm diameter gold nanoparticles at 20 mGy. Conclusion: The implementation of XFCT with a CC is a feasible method for molecular imaging with high atomic number probes. Given constrains of detector resolutions, Doppler broadening, and limited exposure dose, spatial resolutions comparable with PET and molecular sensitivities in the fM range are realizable with current detector technology.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Direct Measurement of Plutonium in Spent Fuel with X-ray Fluoresence

Currently, the only NDA technique that directly measures Pu in SNF involves XRF measurements. Measurements and simulations were used to demonstrate that with a properly - 15 - configured detector system, it is feasible to measure the Pu/U atom ratio at the surface of a fuel pin using measurements of the 103.7 keV K X-ray from Pu. Since the Pu/U atom ratio at the surface of the pin is directly related to the average Pu/U concentration for the pin, the technique might be applicable to measuring the Pu/U concentration in an LWR spent fuel pin. However, the technique requires knowledge of the fuel pin design and operating history to properly correlate surface Pu to average Pu for a pin. Fuel history information is available from operator declarations and can be verified by complementary measurements including gamma spectroscopy and passive gross neutron counts. While the count times of 4 to 12 hours used in these measurements were longer than would be acceptable in most applications, efforts are being made to improve counting time. These include the use of a segmented HPGe detector and reduction of Compton scattering background. These measurements are useful for individual fuel pins and provide a complementary, validating measurement for full assembly techniques. For future work, optimized detector systems and measurement approaches will be explored with the goal of measuring the Pu/U X-ray ratio with shorter count times. Measurements will be compared with the results of destructive analysis, which is to be completed this year, to provide a correlation between the measured Pu/U ratio and the total Pu/U ratio in the fuel. In addition, the sensitivity of this method to variations in system parameters will be studied to determine the expected accuracy of the technique.

Romano, Catherine E.↗

Evaluation of Various Collimators for UF6 Gas Pipe Measurement

On-line gamma measurements of the enrichment of uranium in UF6 gas in pipes is carried out as part of international safeguards. The 186 keV line from 235 U is measured in NaI detectors. One complication in the analysis is that the 186 keV line also comes from the (time-dependent) amount of uranium-bearing material deposited on the interior walls of the pipe. This contribution has to be subtracted before the enrichment of the gas can be calculated. The relative contributions to the total 186 keV count rate from the gas and from the deposit depends on the amount of deposit, but also on the type of collimation/shielding used between the NaI detector and the gas pipe. Several different collimation/shielding designs have been simulated in order to determine which provides the best performance.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

New Measurements on the Neutrino Mass: KATRIN and Project 8 (Final Technical Report for DE-SC0014130)

The overarching goal of the funded research is to build experiments and develop techniques towards the major goal of measuring the mass of the neutrino, particularly by the method of high-resolution spectroscopy of the endpoint of tritium. The goals of this project were to make hardware and intellectual contributions towards the KATRIN experiment, an international project under construction in Germany, and towards the "Project 8" R&D program to develop new electron spectroscopy methods and apply them to tritium. A minor goal of the project was to support simulation work and R&D on future neutrino and dark matter detectors.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Reaction Rate Ratios for Recent Fast Metal Experiments with Large Plutonium Masses

Reaction rate ratios are integral responses that are used within the criticality experiments field because they contain spectral information. While these types of measurements have been utilized for nuclear data validation with historic experiments, few experiments of this type have been utilized for recent experiments, as few exist. This work focuses on measured reaction rate ratios for two nearly bare plutonium critical assemblies with different geometries: one that is cube like (with a Pu mass of 40 kg) and one that is slab like (with a Pu mass of 109 kg). Irradiations were performed with both configurations in which foils were placed near the center of the assembly. Plutonium, highly enriched uranium, depleted uranium, and Au foils were included in the irradiation and counted via high-purity germanium detectors. From these measurements, reaction rate ratios were calculated. Measured and simulated values and uncertainties are presented for the reaction rate ratios. Ratios utilizing the following reactions are given in this work: 197 Au(n, γ), 197 Au(n,2n), 235 U(n,fission), 238 U(n, fission), 238 U(n,2n), 238 U(n,γ), and 239 Pu(n,fission). Uncertainties for the measured reaction rate ratios ranged from 4% to 7%, and the contribution of various parameters to this uncertainty was investigated. The results are compared to historical experiments and should be used for nuclear data validation for future nuclear data library releases. These measurements are part of the EUCLID (Experiments Underpinned by Computational Learning for Improvements in Nuclear Data) project, which utilizes measurement responses in addition to k eff (such as these reaction rate ratios) to help reduce uncertainties in 239 Pu nuclear data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A cosmic dust composition analyzed with a spark ion source

Simulated iron micrometeoroids were fired unto a capacitor-type micrometeoroid detector which responded to an impact with a spark. Large ion currents were extracted from the spark and analyzed in a crude ion time-of-flight mass spectrometer. The mass spectra show the elements of both detector and particle materials.

Auer, S.↗

High resolution Doppler lidar

A high resolution lidar system was implemented to measure winds in the lower atmosphere. The wind speed along the line of sight was determined by measuring the Doppler shift of the aerosol backscattered laser signal. The system in its present configuration is stable, and behaves as indicated by theoretical simulations. This system was built to demonstrate the capabilities of the detector system as a prototype for a spaceborne lidar. The detector system investigated consisted of a plane Fabry-Perot etalon, and a 12-ring anode detector. This system is generically similar to the Fabry-Perot interferometer developed for passive wind measurements on board the Dynamics Explorer satellite. That this detector system performs well in a lidar configuration was demonstrated.

Abreu, Vincent J.↗