Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detection.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Automated detection of hepatotoxic compounds in human hepatocytes using HepaRG cells and image-based analysis of mitochondrial dysfunction with JC-1 dye

In this study, our goal was to develop an efficient in situ test adapted to screen hepatotoxicity of various chemicals, a process which remains challenging during the early phase of drug development. The test was based on functional human hepatocytes using the HepaRG cell line, and automation of quantitative fluorescence microscopy coupled with automated imaging analysis. Differentiated HepaRG cells express most of the specific liver functions at levels close to those found in primary human hepatocytes, including detoxifying enzymes and drug transporters. A triparametric analysis was first used to evaluate hepatocyte purity and differentiation status, mainly detoxication capacity of cells before toxicity testing. We demonstrated that culturing HepaRG cells at high density maintained high hepatocyte purity and differentiation level. Moreover, evidence was found that isolating hepatocytes from 2-week-old confluent cultures limited variations associated with an ageing process occurring over time in confluent cells. Then, we designed a toxicity test based on detection of early mitochondrial depolarisation associated with permeability transition (MPT) pore opening, using JC-1 as a metachromatic fluorescent dye. Maximal dye dimerization that would have been strongly hampered by efficient efflux due to the active, multidrug-resistant (MDR) pump was overcome by coupling JC-1 with the MDR inhibitor verapamil. Specificity of this test was demonstrated and its usefulness appeared directly dependent on conditions supporting hepatic cell competence. This new hepatotoxicity test adapted to automated, image-based detection should be useful to evaluate the early MPT event common to cell apoptosis and necrosis and simultaneously to detect involvement of the multidrug resistant pump with target drugs in a human hepatocyte environment. - Highlights: > We define conditions to preserve differentiation of selective pure HepaRG hepatocyte cultures. > In these conditions, CYPs, transporters expression and activity were similar to a mixed HepaRG population. > Long term differentiation period before HepaRG hepatocyte isolation influence this establishment. > These conditions were settled to develop a hepatoxicity test using automated-imaging analysis. > JC-1 detects MPT, an early event of cell death, in altered HepaRG hepatocytes when efflux of this dye by MDR1 is inhibited.

60 APPLIED LIFE SCIENCES↗

Ex vivo detection of adenovirus specific CD4{sup +} T-cell responses to HLA-DR-epitopes of the Hexon protein show a contracted specificity of T{sub HELPER} cells following stem cell transplantation

Human adenovirus (HAdV) is a cause of significant morbidity and mortality in immunocompromised patients, especially after stem cell transplantation (SCT). Viral clearance has been attributed to CD4{sup +} T-cell responses against the Hexon-protein, but the frequency of specific T{sub HELPER} cells is extremely low or not detectable ex vivo and preference for different CD4{sup +} T-cell epitopes is variable among individuals. We therefore analyzed 44 healthy donors and 6 SCT-recipients for Hexon-specific CD4{sup +}-responses ex vivo, to identify epitopes which would be broadly applicable. We selected 19 candidate epitopes with predicted restriction to HLA-DR1/DR3/DR4/DR7; 16 were located within the highly conserved regions, indicating cross-reactivity of T cells among HAdV-subspecies. Ten epitopes induced CD4{sup +}-proliferation in >50% of individuals, confirmed by intracellular IFN-gamma detection. Three SCT recipients who recovered from an infection with HAdV displayed reactivity towards only a single hexon epitope, whereas healthy individuals were responsive to two to eight epitopes (median 3). The ex vivo detection of Hexon-specific CD4{sup +} T-cells, without any long-term culture in vitro, enables the detection and generation of HAdV-specific CD4{sup +} T cells for adoptive T-cell transfer against HAdV-infection post SCT.

60 APPLIED LIFE SCIENCES↗

Detection and attribution of climate extremes in the observed record

We present an overview of practices and challenges related to the detection and attribution of observed changes in climate extremes. Detection is the identification of a statistically significant change in the extreme values of a climate variable over some period of time. Issues in detection discussed include data quality, coverage, and completeness. Attribution takes that detection of a change and uses climate model simulations to evaluate whether a cause can be assigned to that change. Additionally, we discuss a newer field of attribution, event attribution, where individual extreme events are analyzed for the express purpose of assigning some measure of whether that event was directly influenced by anthropogenic forcing of the climate system.

54 ENVIRONMENTAL SCIENCES↗

Hairpin DNA Switch for Ultrasensitive Spectrophotometric Detection of DNA Hybridization Based on Gold Nanoparticles and Enzyme Signal Amplification

A novel DNA detection platform based on a hairpin-DNA switch, nanoparticles, and enzyme signal amplification for ultrasensitive detection of DNA hybridization has been developed in this work. In this DNA assay, a “stem-loop” DNA probe dually labeled with a thiol at its 5’ end and a biotin at its 3’ end, respectively, was used. This probe was immobilized on the gold nanoparticles (AuNPs) anchored by a protein, globulin, on a 96-well microplate. In the absence of target DNA, the immobilized probe with the stem-loop structure shields the biotin from being approached by a bulky horseradish peroxidase linked-avidin (avidin-HRP) conjugate due to the steric hindrance. However, in the presence of target DNA, the hybridization between the hairpin DNA probe and the target DNA causes significant conformational change of the probe, which forces biotin away from the surface of AuNPs. As a result, the biotin becomes accessible by the avidin-HRP, and the target hybridization event can be sensitively detected via the HRP catalyzed substrate 3, 3', 5, 5'-tetramethylbenzidine using spectrophometric method. Some experimental parameters governing the performance of the assay have been optimized. At optimal conditions, this DNA assay can detect DNA at the concentration of femtomolar level by means of a signal amplification strategy based on the combination of enzymes and nanoparticles. This approach also has shown excellent specificity to distinguish single-base mismatches of DNA targets because of the intrinsic high selectivity of the hairpin DNA probe.

59 BASIC BIOLOGICAL SCIENCES↗

Metal–Organic Framework-Based Microfluidic Impedance Sensor Platform for Ultrasensitive Detection of Perfluorooctanesulfonate

The growing global concerns to public health from human exposure to perfluorooctanesulfonate (PFOS) requires rapid, sensitive, in-situ detection where current, state-of-the-art techniques are yet to adequately meet sensitivity and selectivity standards of the real-world. This work presents, for the first time, a synergistic approach for the targeted affinity-based capture of PFOS using a porous sorbent probe that enhances detection sensitivity by embedding it on a microfluidic conductive platform. This novel sorbent-containing platform functions as an electrochemical sensor to directly measure PFOS concentration through a proportional change in electrical response (increase in impedance). The extremely high surface area and pore volume of mesoporous metal-organic framework (MOF) Cr-MIL-101 is used as the probe for targeted PFOS capture based on the affinity of the chromium center towards both the fluorine tail groups as well as the sulfonate functionalities as demonstrated by spectroscopic (NMR and XPS) and microscopic (TEM) studies. Answering the need for an ultrasensitive PFOS detection technique, we are embedding these MOF capture probes inside a microfluidic channel, sandwiched between interdigitated microelectrodes (IDµE). The nanoporous geometry increases the signal to noise ratio of interdigitated microelectrodes tremendously increasing sensitivity; this in combination with the ability of the capture probes to interact with the PFOS at the molecular level and effectively transduce that response electrochemically has allowed us achieve a PFOS detection limit of 0.5 ng/L, which is unprecedented for in-situ analytical PFOS sensors and even comparable to quantification limits achieved using state-of-the-art ex situ techniques.

36 MATERIALS SCIENCE↗

APTAMER-BASED SERRS SENSOR FOR THROMBIN DETECTION

We describe an aptamer-based Surface Enhanced Resonance Raman Scattering (SERRS) sensor with high sensitivity, specificity, and stability for the detection of a coagulation protein, human a-thrombin. The sensor achieves high sensitivity and a limit of detection of 100 pM by monitoring the SERRS signal change upon the single step of thrombin binding to immobilized thrombin binding aptamer. The selectivity of the sensor is demonstrated by the specific discrimination of thrombin from other protein analytes. The specific recognition and binding of thrombin by the thrombin binding aptamer is essential to the mechanism of the aptamer-based sensor, as shown through measurements using negative control oligonucleotides. In addition, the sensor can detect 1 nM thrombin in the presence of complex biofluids, such as 10% fetal calf serum, demonstrating that the immobilized, 5{prime}-capped, 3{prime}-capped aptamer is sufficiently robust for clinical diagnostic applications. Furthermore, the proposed sensor may be implemented for multiplexed detection using different aptamer-Raman probe complexes.

59 BASIC BIOLOGICAL SCIENCES↗

Improved explosive collection and detection with rationally assembled surface sampling materials

Sampling and detection of trace explosives is a key analytical process in modern transportation safety. In this work we have explored some of the fundamental analytical processes for collection and detection of trace level explosive on surfaces with the most widely utilized system, thermal desorption IMS. The performance of the standard muslin swipe material was compared with chemically modified fiberglass cloth. The fiberglass surface was modified to include phenyl functional groups. When compared to standard muslin, the phenyl functionalized fiberglass sampling material showed better analyte release from the sampling material as well as improved response and repeatability from multiple uses of the same swipe. The improved sample release of the functionalized fiberglass swipes resulted in a significant increase in sensitivity. Various physical and chemical properties were systematically explored to determine optimal performance. The results herein have relevance to improving the detection of other explosive compounds and potentially to a wide range of other chemical sampling and field detection challenges.

Explosive detection↗

First GRB detections with the AGILE Minicalorimeter

The Minicalorimeter (MCAL) onboard the AGILE satellite is a 1400 cm{sup 2} scintillation detector sensitive in the energy range 0.3-200 MeV. MCAL works both as a slave of the AGILE Silicon Tracker and as an autonomous detector for transient events (BURST mode). A dedicated onboard Burst Search logic scans BURST mode data in search of count rate increase. Peculiar characteristics of the detector are the high energy spectral coverage and a timing resolution of about 2 microseconds. Even if a trigger is not issued, BURST mode data are used to build a broad band energy spectrum (scientific ratemeters) organized in 11 bands for each of the two MCAL detection planes, with a time resolution of 1 second. After the first engineering commissioning phase, following the AGILE launch on 23rd April 2007, between 22nd June and 5th November 2007 eighteen GRBs were detected offline in the scientific ratemeters data, with a detection rate of about one per week. In this paper the capabilities of the detector will be described and an overview of the first detected GRBs will be given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detection and Characterisation of H-{alpha} Emission Lines from Gaia BP/RP Spectra

The Gaia probe, set to launch in 2011, will measure an estimated billion astronomical objects, producing an enormous amount of data. One of the data analysis tasks will be the identification and classification of measured objects. A vast majority of them will be 'ordinary' stars from our Galaxy but a certain percentage will belong to 'peculiar' objects. We are interested in detecting emission line stars (ELS). The characteristic feature of most ELS is the presence of a H-{alpha} emission line in their spectra. In the case of Gaia measurements, the influence of this line could be detected in low resolution prismatic spectra which will be recorded both in blue (BP) and red (RP) spectral region. In this work, we compare different algorithms for detecting and characterising H-{alpha} lines in Gaia spectra. These include a simple, integrated flux ratio-based algorithm and several machine learning algorithms, such as neural networks, support vector machines and support vector regression. We study line detection both from single-transit and over-sampled end-of-mission data.

79 ASTRONOMY AND ASTROPHYSICS↗

Radio-frequency electromagnetic field measurements for direct detection of electron Bernstein waves in a torus plasma

To identify the mode-converted electron Bernstein wave (EBW) in a torus plasma directly, we have developed an interferometry system, in which a diagnostic microwave injected outside of the plasma column was directly detected with the probing antenna inserted into the plasma. In this work, plasma production and heating are achieved with 2.45 GHz, 2.5 kW electron cyclotron heating (ECH), whereas diagnostics are carried out with a lower power (10 W) separate frequency (1-2.1 GHz) microwave. Three components, i.e., two electromagnetic (toroidal and poloidal directions) and an electrostatic (if refractive index is sufficiently higher than unity, it corresponds to radial component), of ECRF electric field are simultaneously measured with three probing antennas, which are inserted into plasma. Selectivities of each component signal were checked experimentally. Excitation antennas have quite high selectivity of direction of linear polarization. As probing antennas for detecting electromagnetic components, we employed a monopole antenna with a length of 35 mm, and the separation of the poloidal (O-wave) and toroidal (X-wave) components of ECRF electric field could be available with this antenna. To detect EBW, which is an electrostatic wave, a small tip (1 mm) antenna was used. As the preliminary results, we detected signals that have three characteristics of EBW, i.e., short wavelength, backward propagation, and electrostatic.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fissile Material Detection by Differential Die Away Analysis

Detection and interdiction of Special Nuclear Material (SNM) in transportation is one of the most critical security issues facing the United States. Active inspection by inducing fission in fissile nuclear materials, such as {sup 235}U and {sup 239}Pu, provides several strong and unique signatures that make the detection of concealed nuclear materials technically very feasible. Differential Die-Away Analysis (DDAA) is a very efficient, active neutron-based technique that uses the abundant prompt fission neutrons signature. It benefits from high penetrability of the probing and signature neutrons, high fission cross section, high detection sensitivity, ease of deployment and relatively low cost. DDAA can use any neutron source or energy as long as it can be suitably pulsed. The neutron generator produces pulses of neutrons that are directed into a cargo. As each pulse passes through the cargo, the neutrons are thermalized and absorbed. If SNM is present, the thermalized neutrons create a new source of (fission) neutrons with a distinctive time profile. An efficient laboratory system was designed, fabricated and tested under a US Government DHS DNDO contract. It was shown that a small uranium sample can be detected in a large variety of cargo types and configurations within practical measurement times using commercial compact (d,T) sources. Using stronger sources and wider detector distribution will further cut inspection time. The system can validate or clear alarms from a primary inspection system such as an automated x-ray system.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Detection of fast nanoparticles in the solar wind

Dust grains in the nanometer range bridge the gap between atoms and larger grains made of bulk material. Their small size embodies them with special properties. Due to their high relative surface area, they have a high charge-to-mass ratio, so that the Lorentz force in the solar wind magnetic field exceeds the gravitational force and other forces by a large amount, and they are accelerated to a speed of the order of magnitude of the solar wind speed. When such fast nanoparticles impact a spacecraft, they produce craters whose matter vaporises and ionises, yielding transient voltages as high as do much larger grains of smaller speed. These properties are at the origin of their recent detection at 1 AU in the solar wind. We discuss the detection of fast nanoparticles by wave instruments of different configurations, with applications to the recent detections on STEREO/WAVES and CASSINI/RPWS. Finally we discuss the opportunities for nanoparticle detection by wave instruments on future missions and/or projects in the inner heliosphere such as Bepi-Colombo and Solar Orbiter.

79 ASTRONOMY AND ASTROPHYSICS↗

Single particle detection: Phase control in submicron Hall sensors

We present a phase-sensitive ac-dc Hall magnetometry method which allows a clear and reliable separation of real and parasitic magnetic signals of a very small magnitude. High-sensitivity semiconductor-based Hall crosses are generally accepted as a preferential solution for non-invasive detection of superparamagnetic nanobeads used in molecular biology, nanomedicine, and nanochemistry. However, detection of such small beads is often hindered by inductive pick-up and other spurious signals. The present work demonstrates an unambiguous experimental route for detection of small magnetic moments and provides a simple theoretical background for it. The reliability of the method has been tested for a variety of InSb Hall sensors in the range 600 nm-5 {mu}m. Complete characterization of empty devices, involving Hall coefficients and noise measurements, has been performed and detection of a single FePt bead with diameter of 140 nm and magnetic moment of {mu}{approx_equal}10{sup 8} {mu}{sub B} has been achieved with a 600 nm-wide sensor.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Real-time nonlinear correction of back-focal-plane detection in optical tweezers

Photodiode based detection of laser trapped beads using forward scattered light is a frequently employed technique for position measurement. There is a nonlinear relationship between photodiode outputs and bead position but for small displacements linear approximation holds well. Traditionally, the nonlinearity is compensated by normalizing the photodiode's position signal with the intensity signal and then using a polynomial fit in the range where voltage to position mapping is one to one. In this article, this range is extended by using the intensity signal as an independent input along with the two position signals. A map from the input signals to the actual position values is obtained. This mapping is one-to-one for a larger range that results in an increased detection range. An artificial neural network that facilitates implementation is employed for this purpose. This scheme is implemented on a Field Programmable Gate Array based data acquisition and control hardware with closed loop bandwidth of 50 kHz. Detection of the order of 350 nm from the center of detection laser is demonstrated for a 500 nm diameter bead compared to 180 nm achieved by a polynomial fit.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nuclear-Reaction-Based Radiation Source For Explosives-And SNM-Detection In Massive Cargo

An automatic, nuclear-reaction-based, few-view transmission radiography method and system concept is presented, that will simultaneously detect small, operationally-relevant quantities of chemical explosives and special nuclear materials (SNM) in objects up to the size of LD-3 aviation containers. Detection of all threat materials is performed via the {sup 11}B(d,n+{gamma}) reaction on thick, isotopically-enriched targets; SNM are primarily detected via Dual Discrete-Energy Radiography (DDER), using 15.11 MeV and 4.43 MeV {sup 12}C{gamma}-rays, whereas explosives are primarily detected via Fast Neutron Resonance Radiography (FNRR), employing the broad-energy neutron spectra produced in a thick {sup 11}B-target. To achieve a reasonable throughput of {approx}20 containers per hour, ns-pulsed deuteron beam of the order of 0.5 mA intensity at energies of 5-7 MeV is required. As a first step towards optimizing parameters and sensitivities of an operational system, the 0 deg. spectra and yields of both {gamma}-rays and neutrons in this reaction have been measured up to E{sub d} = 6.65 MeV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

An ultra-high-energy-neutrino detector using rock salt and ice as detection media for radar method

We had found radio-wave-reflection effect in rock salt for detection of an ultra-high energy neutrino (UHE{nu}) which is generated in GZK processes in the universe. When an UHE{nu} interacts with rock salt or ice as a detection medium, the energy converts to a thermal energy. Consequently, a temperature gives rise along an UHE{nu} shower at the interaction location. The permittivity arises with respect to the temperature at ionization processes of the UHE{nu} shower which is composed of hadronic and electromagnetic multiplication processes. The irregularity of the refractive index in the medium for radio wave rises to a reflection. The reflection effect with a long attenuation length of radio wave in rock salt and ice would yield a new method to detect UHE{nu}. They could be used for detection media in which the UHE{nu} interacts with. We could find a huge amount of rock salt or ice over 50 Gt in a natural rock salt formation or Antarctic ice sheet. Radio wave transmitted into the medium generated by a radar system could be reflected by the irregularity of the refractive index at the shower. Receiving the reflected radio wave yields information about the UHE{nu}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Standoff alpha radiation detection via excited state absorption of air

A standoff alpha radiation detection technique based on the physical mechanism of excited state absorption of air molecules was explored and is presented in this paper. Instead of directly detecting the radiation via measuring the intensity of radiation induced air fluorescence, the radiation is detected via the excited state absorption of alpha radiation excited/ionized air molecules. Both theoretical analyses and experimental verifications were conducted. The experimental results confirmed that the radiation could be detected via excited state absorption of radiation excited/ionized air molecules at a 10 m standoff distance, which was consistent with the theoretical analyses.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Low background high efficiency radiocesium detection system based on positron emission tomography technology

After the 2011 nuclear power plant accident at Fukushima, radiocesium contamination in food became a serious concern in Japan. However, low background and high efficiency radiocesium detectors are expensive and huge, including semiconductor germanium detectors. To solve this problem, we developed a radiocesium detector by employing positron emission tomography (PET) technology. Because {sup 134}Cs emits two gamma photons (795 and 605 keV) within 5 ps, they can selectively be measured with coincidence. Such major environmental gamma photons as {sup 40}K (1.46 MeV) are single photon emitters and a coincidence measurement reduces the detection limit of radiocesium detectors. We arranged eight sets of Bi{sub 4}Ge{sub 3}O{sub 12} (BGO) scintillation detectors in double rings (four for each ring) and measured the coincidence between these detectors using PET data acquisition system. A 50 × 50 × 30 mm BGO was optically coupled to a 2 in. square photomultiplier tube (PMT). By measuring the coincidence, we eliminated most single gamma photons from the energy distribution and only detected those from {sup 134}Cs at an average efficiency of 12%. The minimum detectable concentration of the system for the 100 s acquisition time is less than half of the food monitor requirements in Japan (25 Bq/kg). These results show that the developed radiocesium detector based on PET technology is promising to detect low level radiocesium.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Refine your search to explore more results.