Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DOSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Madidrop for Passive Silver Dosing

Madidrop is a rectangular ceramic tablet originally designed to dose a 10-20-liter volume of water with silver to act as a biocide for remote communities with unreliable water sources. Silver as a biocide is a proposed method to control bacteria on the International Space Station or future Artemis missions. This would replace iodine currently used due to issues with a dual biocide system in place between Russian and US segments and the extra cost of iodine removal required before consumption. NASA has been reviewing this Madidrop technology and its potential application with a water reclamation system on orbit to dose silver after purifying the water. While there are a couple alternative methods to dosing silver on station, this method is like the existing passive dosing method used currently to dose iodine. Tests conducted characterize the manufacturer’s original intent to leave the tablet in a tank for a specified amount of time before removing and testing alternative passive flow-through methods. Passive flow testing involved two options: keeping the tablet intact or crushing the tablet into smaller particle sizes to increase the surface area while varying particle sizes. The results of these tests revealed a large amount of silver output at first that quickly reduced to a constant lower output within a reasonable dosing concentration range. The initial high concentration peaks after a couple days of quiescence and could be useful for shocking the initial tank water contents. Madidrop used as a passive particle doser could act as a stand-in replacement for iodine in future spaceflight water reclamation systems.

Ryan Ogilvie↗

Madidrop for Passive Silver Dosing

Madidrop is a rectangular ceramic tablet originally designed to dose a 10-20-liter volume of water with silver to act as a biocide for remote communities with unreliable water sources. Silver as a biocide is a proposed method to control bacteria on the International Space Station or future Artemis missions. This would replace iodine currently used due to issues with a dual biocide system in place between Russian and US segments and the extra cost of iodine removal required before consumption. NASA has been reviewing this Madidrop technology and its potential application with a water reclamation system on orbit to dose silver after purifying the water. While there are a couple alternative methods to dosing silver on station, this method is like the existing passive dosing method used currently to dose iodine. Tests conducted characterize the manufacturer’s original intent to leave the tablet in a tank for a specified amount of time before removing and testing alternative passive flow-through methods. Passive flow testing involved two options: keeping the tablet intact or crushing the tablet into smaller particle sizes to increase the surface area while varying particle sizes. The results of these tests revealed a large amount of silver output at first that quickly reduced to a constant lower output within a reasonable dosing concentration range. The initial high concentration peaks after a couple days of quiescence and could be useful for shocking the initial tank water contents. Madidrop used as a passive particle doser could act as a stand-in replacement for iodine in future spaceflight water reclamation systems.

Ryan Ogilvie↗

Dose-Dependent Analysis of Acute Medical Effects of Mixed Neutron-Gamma Radiation from Selected Severe Uranium-235 or Plutonium-239 Criticality Accidents in USSR, United States and Argentina

Eight of the most severe cases of acute radiation disease (ARS) known to have occurred in man (as the result of criticality accidents) had survival times less than 120 hours (herein defined as “early death”). These accidents were analyzed and are discussed with respect to the specific accident scenarios and the resulting accident specific, mixed neutron-gamma radiation clinical dose distributions. Our analysis concludes that the cardiovascular system appears to be the most critical organ system failure for causing “early death”, following approximate total body, mixed gamma-neutron irradiations doses greater than 40–50 Gy. The clinical data also suggests that there is definite chest dose dependence in the resulting survival times for these eight workers, who unfortunately suffered profound radiation injury and unusual clinical effects from such high dose radiation exposures. In addition “toxemic syndrome” is correlated with the irradiation of large volumes of soft tissues. Doses to the hands or legs greater than 80 –100 Gy or radiation lung injury also play significant, but secondary, roles for causing “early death”, in accidents delivering chest doses greater than 50 Gy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Method to determine the position-dependant metal correction factor for dose-rate equivalent laser testing of semiconductor devices

A method reconstructs the charge collection from regions beneath opaque metallization of a semiconductor device, as determined from focused laser charge collection response images, and thereby derives a dose-rate dependent correction factor for subsequent broad-area, dose-rate equivalent, laser measurements. The position- and dose-rate dependencies of the charge-collection magnitude of the device are determined empirically and can be combined with a digital reconstruction methodology to derive an accurate metal-correction factor that permits subsequent absolute dose-rate response measurements to be derived from laser measurements alone. Broad-area laser dose-rate testing can thereby be used to accurately determine the peak transient current, dose-rate response of semiconductor devices to penetrating electron, gamma- and x-ray irradiation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

PET/CT-guided Interventions: Personnel Radiation Dose

PurposeTo quantify radiation exposure to the primary operator and staff during PET/CT-guided interventional procedures.MethodsIn this prospective study, 12 patients underwent PET/CT-guided interventions over a 6 month period. Radiation exposure was measured for the primary operator, the radiology technologist, and the nurse anesthetist by means of optically stimulated luminescence dosimeters. Radiation exposure was correlated with the procedure time and the use of in-room image guidance (CT fluoroscopy or ultrasound).ResultsThe median effective dose was 0.02 (range 0-0.13) mSv for the primary operator, 0.01 (range 0-0.05) mSv for the nurse anesthetist, and 0.02 (range 0-0.05) mSv for the radiology technologist. The median extremity dose equivalent for the operator was 0.05 (range 0-0.62) mSv. Radiation exposure correlated with procedure duration and with the use of in-room image guidance. The median operator effective dose for the procedure was 0.015 mSv when conventional biopsy mode CT was used, compared to 0.06 mSv for in-room image guidance, although this did not achieve statistical significance as a result of the small sample size (p = 0.06).ConclusionThe operator dose from PET/CT-guided procedures is not significantly different than typical doses from fluoroscopically guided procedures. The major determinant of radiation exposure to the operator from PET/CT-guided interventional procedures is time spent in close proximity to the patient.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Influence of Dose on Risk of Acute Urinary Retention After Iodine-125 Prostate Brachytherapy

Purpose: To assess the influence of dose on the risk of acute urinary retention (AUR) after iodine-125 prostate brachytherapy. Methods and Materials: Between January 2005 and December 2008, 714 consecutive patients with localized prostate cancer were treated with iodine-125 prostate brachytherapy at our department. All patients completed four imaging studies: magnetic resonance imaging before and 4 weeks after treatment and intraoperative three-dimensional transrectal ultrasonography before and after implantation. The development of AUR was prospectively recorded. The evaluated treatment and dosimetric parameters included prostate volume, number of needles and seeds used, intra- and postoperative prostate edema, percentage of prostate volume receiving 100%, 150%, and 200% of the prescribed dose to the prostate, minimal dose received by 90% of the prostate volume, and percentage of the urethra receiving 100%, 150%, and 200% of the prescribed dose. Logistic regression analysis was used to examine which factors were associated with AUR. Results: Of the 714 patients, 57 (8.0%) developed AUR. On univariate analysis, the following treatment and dosimetric factors were significantly associated with AUR: International Prostate Symptom Score (odds ratio [OR], 2.07, per 10-point increase), preimplant prostate volume (OR, 1.06), postimplant prostate volume (OR, 1.04), number of needles used (OR, 1.09), and number of seeds used (OR, 1.03). On multivariate analysis, the only independent predictive factors for AUR were pretreatment prostate volume (OR, 1.05) and International Prostate Symptom Score (OR, 1.76, per 10-point increase). Patients with a pretreatment prostate volume >35 cm{sup 3} had a 10.4% risk of developing AUR compared with 5.4% for those with a prostate volume of {<=}35 cm{sup 3}. No association was found between any of the dosimetric parameters and the development of AUR. Conclusion: The radiation dose, within the range studied, did not influence the risk of AUR after iodine-125 prostate brachytherapy. Prostate volume and International Prostate Symptom Score were the most important predictors of AUR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose-Volume Histogram Parameters and Clinical Factors Associated With Pleural Effusion After Chemoradiotherapy in Esophageal Cancer Patients

Purpose: To investigate the dose-volume histogram parameters and clinical factors as predictors of pleural effusion in esophageal cancer patients treated with concurrent chemoradiotherapy (CRT). Methods and Materials: Forty-three esophageal cancer patients treated with definitive CRT from January 2001 to March 2007 were reviewed retrospectively on the basis of the following criteria: pathologically confirmed esophageal cancer, available computed tomography scan for treatment planning, 6-month follow-up after CRT, and radiation dose {>=}50 Gy. Exclusion criteria were lung metastasis, malignant pleural effusion, and surgery. Mean heart dose, mean total lung dose, and percentages of heart or total lung volume receiving {>=}10-60 Gy (Heart-V{sub 10} to V{sub 60} and Lung-V{sub 10} to V{sub 60}, respectively) were analyzed in relation to pleural effusion. Results: The median follow-up time was 26.9 months (range, 6.7-70.2) after CRT. Of the 43 patients, 15 (35%) developed pleural effusion. By univariate analysis, mean heart dose, Heart-V{sub 10} to V{sub 60}, and Lung-V{sub 50} to V{sub 60} were significantly associated with pleural effusion. Poor performance status, primary tumor of the distal esophagus, and age {>=}65 years were significantly related with pleural effusion. Multivariate analysis identified Heart-V{sub 50} as the strongest predictive factor for pleural effusion (p = 0.01). Patients with Heart-V{sub 50} <20%, 20%{<=} Heart-V{sub 50} <40%, and Heart-V{sub 50} {>=}40% had 6%, 44%, and 64% of pleural effusion, respectively (p < 0.01). Conclusion: Heart-V{sub 50} is a useful parameter for assessing the risk of pleural effusion and should be reduced to avoid pleural effusion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose Escalation for Metastatic Spinal Cord Compression in Patients With Relatively Radioresistant Tumors

Purpose: Radiotherapy alone is the most common treatment for metastatic spinal cord compression (MSCC) from relatively radioresistant tumors such as renal cell carcinoma, colorectal cancer, and malignant melanoma. However, the results of the 'standard' regimen 30 Gy/10 fractions need to be improved with respect to functional outcome. This study investigated whether a dose escalation beyond 30 Gy can improve treatment outcomes. Methods and Materials: A total of 91 patients receiving 30 Gy/10 fractions were retrospectively compared to 115 patients receiving higher doses (37.5 Gy/15 fractions, 40 Gy/20 fractions) for motor function and local control of MSCC. Ten further potential prognostic factors were evaluated: age, gender, tumor type, performance status, number of involved vertebrae, visceral or other bone metastases, interval from tumor diagnosis to radiotherapy, pretreatment ambulatory status, and time developing motor deficits before radiotherapy. Results: Motor function improved in 18% of patients after 30 Gy and in 22% after higher doses (p = 0.81). On multivariate analysis, functional outcome was associated with visceral metastases (p = 0.030), interval from tumor diagnosis to radiotherapy (p = 0.010), and time developing motor deficits (p < 0.001). The 1-year local control rates were 76% after 30 Gy and 80% after higher doses, respectively (p = 0.64). On multivariate analysis, local control was significantly associated with visceral metastases (p = 0.029) and number of involved vertebrae (p = 0.043). Conclusions: Given the limitations of a retrospective study, escalation of the radiation dose beyond 30 Gy/10 fractions did not significantly improve motor function and local control of MSCC in patients with relatively radioresistant tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dedicated Linear Accelerator Radiosurgery for Trigeminal Neuralgia: A Single-Center Experience in 179 Patients With Varied Dose Prescriptions and Treatment Plans

Purpose: Dedicated linear accelerator radiosurgery (D-LINAC) has become an important treatment for trigeminal neuralgia (TN). Although the use of gamma knife continues to be established, few large series exist using D-LINAC. The authors describe their results, comparing the effects of varied target and dose regimens. Methods and Materials: Between August 1995 and January 2008, 179 patients were treated with D-LINAC radiosurgery. Ten patients (5.58%) had no clinical follow-up. The median age was 74.0 years (range, 32-90 years). A total of 39 patients had secondary or atypical pain, and 130 had idiopathic TN. Initially, 28 patients received doses between 70 and 85 Gy, with the 30% isodose line (IDL) touching the brainstem. Then, using 90 Gy, 82 consecutive patients were treated with a 30% IDL and 59 patients with a 50% IDL tangential to the pons. Results: Of 169 patients, 134 (79.3%) experienced significant relief at a mean of 28.8 months (range, 5-142 months). Average time to relief was 1.92 months (range, immediate to 6 months). A total of 31 patients (19.0%) had recurrent pain at 13.5 months. Of 87 patients with idiopathic TN without prior procedures, 79 (90.8%) had initial relief. Among 28 patients treated with 70 Gy and 30% IDL, 18 patients (64.3%) had significant relief, and 10 (35.7%) had numbness. Of the patients with 90 Gy and 30% IDL at the brainstem, 59 (79.0%) had significant relief and 48.9% had numbness. Among 59 consecutive patients with similar dose but the 50% isodoseline at the brainstem, 49 patients (88.0%) had excellent/good relief. Numbness, averaging 2.49 on a subjective scale of 1 to 5, was experienced by 49.7% of the patients, Conclusions: Increased radiation dose and volume of brainstem irradiation may improve clinical outcomes with the trade-off of trigeminal dysfunction. Further study of the implications of dose and target are needed to optimize outcomes and to minimize complications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of Dose on Local Failure Rates After Image-Guided Reirradiation of Recurrent Paraspinal Metastases

Purpose: To examine the impact of dose on local failure (LF) rates in the re-treatment of recurrent paraspinal metastases with image-guided intensity-modulated radiotherapy (IG-IMRT). Methods and Materials: The records of patients with in-field recurrence after previous spine radiation (median dose, 30 Gy) who received salvage IG-IMRT with either five 4-Gy (20-Gy group, n = 42) or five 6-Gy (30-Gy group, n = 55) daily fractions between January 2003 and August 2008 were reviewed. Institutional practice was 20 Gy before April 2006, when it changed to 30 Gy. A total of 47 cases (48%) were treated adjuvantly, after surgery to decompress epidural disease. LF after IG-IMRT was defined radiographically. Results: The median follow-up was 12.1 months (range, 0.2-63.6 months). The 1-year cumulative incidences of LF after 20 Gy and 30 Gy IG-IMRT were 45% and 26%, respectively (p = 0.04). Of all treatment characteristics examined (20-Gy vs. 30-Gy dose group, dose to 95% of the planned and gross target volume, tumor size, histology, receipt of surgery, and interval between first and second radiation), only dose group had a significant impact on actuarial LF incidence (p = 0.04; unadjusted HR, 0.51; 95% CI, 0.27-0.96). There was no incidence of myelopathy. Conclusions: A significant decrease in LF after IG-IMRT with five 6-Gy fractions compared with five 4-Gy fractions was observed without increased risk of myelopathy. Until prospective data comparing stereotactic hypofractionated and single-fraction regimens become available, when reirradiating recurrent paraspinal metastases with IG-IMRT, administration of five 6-Gy daily fractions is reasonable.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prolongation of Total Treatment Time Because of Infrequently Missed Days of Treatment Is Not Associated With Inferior Biochemical Outcome After Dose-Escalated Radiation Therapy for Prostate Cancer

Purpose: Prolongation of treatment time with radiation therapy (RT) is associated with inferior disease control for many rapidly proliferating tumors, but it is uncertain whether the same effect is seen in prostate cancer. Methods and Materials: 596 patients underwent with curative-intent RT for adenocarcinoma of the prostate. By National Comprehensive Cancer Network criteria, men were classified as having low-risk (30%), medium-risk (40%), or high-risk (30%) disease. The median RT dose was 72 Gy. Androgen-deprivation therapy (ADT) was used in 45%. The idealized treatment time was defined as the total elapsed time (including weekends) to complete treatment if started on a Monday. Missed days of treatment, defined as the number of days beyond the idealized treatment time, was recorded for all patients. Missed days were added to the end of therapy resulting in a longer treatment time. Analysis was conducted for missed days and other standard prognostic variables against freedom from biochemical failure (FFBF). Results: The median number of missed days was 2 (range, -3 to 22). With a median follow-up of 51 months, men with 5 or more missed days had similar 4-year FFBF rates (79% vs. 83% in men with <5 missed days, p = 0.0809), especially in the subset of men receiving 74 Gy or greater (89% for both groups, p = 0.8008). Analysis of missed days was performed for the subsets of dose, ADT, and risk category. Men without ADT had a lower FFBF rate with more missed days (p = 0.0030), but this association was not seen in men treated to a dose of 74 Gy or greater (p = 0.7425). On multivariate analysis, dose (p = 0.0010), T stage (p = 0.0145), and prostate-specific antigen level (p < 0.0001) were associated with FFBF, but Gleason score (p = 0.1351) and missed days (p = 0.3767) were not. Conclusions: Slight prolongation of treatment time (e.g., {<=}7 days) was not associated with inferior FFBF, especially in men receiving an RT dose of 74 Gy or greater.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Acute and Late Toxicities for Three Modern High-Dose Radiation Treatment Techniques for Localized Prostate Cancer

Purpose: We compared acute and late genitourinary (GU) and gastrointestinal (GI) toxicities in prostate cancer patients treated with three different high-dose radiation techniques. Methods and Materials: A total of 1,903 patients with localized prostate cancer were treated with definitive RT at William Beaumont Hospital from 1992 to 2006: 22% with brachytherapy alone (BT), 55% with image-guided external beam (EB-IGRT), and 23% external beam with high-dose-rate brachytherapy boost (EBRT+HDR). Median dose with BT was 120 Gy for LDR and 38 Gy for HDR (9.5 Gy Multiplication-Sign 4). Median dose with EB-IGRT was 75.6 Gy (PTV) to prostate with or without seminal vesicles. For EBRT+HDR, the pelvis was treated to 46 Gy with an additional 19 Gy (9.5 Gy Multiplication-Sign 2) delivered via HDR. GI and GU toxicity was evaluated utilizing the NCI-CTC criteria (v.3.0). Median follow-up was 4.8 years. Results: The incidences of any acute {>=} Grade 2 GI or GU toxicities were 35%, 49%, and 55% for BT, EB-IGRT, and EBRT+HDR (p < 0.001). Any late GU toxicities {>=} Grade 2 were present in 22%, 21%, and 28% for BT, EB-IGRT, and EBRT+HDR (p = 0.01), respectively. Patients receiving EBRT+HDR had a higher incidence of urethral stricture and retention, whereas dysuria was most common in patients receiving BT. Any Grade {>=}2 late GI toxicities were 2%, 20%, and 9% for BT, EB-IGRT, and EBRT+HDR (p < 0.001). Differences were most pronounced for rectal bleeding, with 3-year rates of 0.9%, 20%, and 6% (p < 0.001) for BT, EB-IGRT, and EBRT+HDR respectively. Conclusions: Each of the three modern high-dose radiation techniques for localized prostate cancer offers a different toxicity profile. These data can help patients and physicians to make informed decisions regarding radiotherapy for prostate andenocarcinoma.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-Dose-Rate Monotherapy: Safe and Effective Brachytherapy for Patients With Localized Prostate Cancer

Purpose: High-dose-rate (HDR) brachytherapy used as the only treatment (monotherapy) for early prostate cancer is consistent with current concepts in prostate radiobiology, and the dose is reliably delivered in a prospectively defined anatomic distribution that meets all the requirements for safe and effective therapy. We report the disease control and toxicity of HDR monotherapy from California Endocurietherapy (CET) and William Beaumont Hospital (WBH) in low- and intermediate-risk prostate cancer patients. Methods and Materials: There were 298 patients with localized prostate cancer treated with HDR monotherapy between 1996 and 2005. Two biologically equivalent hypofractionation protocols were used. At CET the dose was 42 Gy in six fractions (two implantations 1 week apart) delivered to a computed tomography-defined planning treatment volume. At WBH the dose was 38 Gy in four fractions (one implantation) based on intraoperative transrectal ultrasound real-time treatment planning. The bladder, urethral, and rectal dose constraints were similar. Toxicity was scored with the National Cancer Institute Common Toxicity Criteria for Adverse Events version 3. Results: The median follow-up time was 5.2 years. The median age of the patients was 63 years, and the median value of the pretreatment prostate-specific antigen was 6.0 ng/mL. The 8-year results were 99% local control, 97% biochemical control (nadir +2), 99% distant metastasis-free survival, 99% cause-specific survival, and 95% overall survival. Toxicity was scored per event, meaning that an individual patient with more than one symptom was represented repeatedly in the morbidity data table. Genitourinary toxicity consisted of 10% transient Grade 2 urinary frequency or urgency and 3% Grade 3 episode of urinary retention. Gastrointestinal toxicity was <1%. Conclusions: High disease control rates and low morbidity demonstrate that HDR monotherapy is safe and effective for patients with localized prostate cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Semicontinuous Low-Dose-Rate Teletherapy for the Treatment of Recurrent Glial Brain Tumors: Final Report of a Phase I/II Study

Purpose: Semicontinuous low-dose-rate teletherapy (SLDR) is a novel irradiation strategy that exploits the increased radiosensitivity of glial cells in a narrow range of reduced dose rate. We present the final report of a prospective Phase I/II study testing the feasibility of SLDR for the treatment of recurrent gliomas. Methods and Materials: Patients with previously irradiated recurrent gliomas were enrolled from November 1993 to March 1998. Patients received SLDR, delivered 6 to 8 hours/day at a dose rate of 40 to 50 cGy/hour for a total dose of 30 to 35 Gy given over 12 days using a modified cobalt-60 treatment unit. Acute central nervous system toxicity after SLDR treatment was the primary endpoint. Overall survival was a secondary endpoint. Results: Twenty patients were enrolled (14 World Health Organization Grade 4 glioma, 5 Grade 2 glioma, 1 ependymoma). No patients developed {>=}Grade 3 central nervous system toxicity at 3 months without radiographic evidence of tumor progression. Overall survival after SLDR was 56% at 6 months, 28% at 12 months, and 17% at 24 months. One patient survived >48 months, and 1 patient survived >60 months after SLDR treatment. Re-resection before SLDR treatment significantly improved 1-year overall survival for all patients and patients with Grade 4 glioma. Conclusion: The delivery of SLDR is feasible in patients with recurrent gliomas and resulted in improved outcomes for patients who underwent re-resection. There were 2 long-term survivors (>48 months). This pilot study supports the notion that reduced dose rate influences the efficacy and tolerance of reirradiation in the treatment of recurrent gliomas.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-Dose-Rate Brachytherapy as Monotherapy Delivered in Two Fractions Within One Day for Favorable/Intermediate-Risk Prostate Cancer: Preliminary Toxicity Data

Purpose: To report the toxicity profile of high-dose-rate (HDR)-brachytherapy (BT) as monotherapy in a Human Investigation Committee-approved study consisting of a single implant and two fractions (12 Gy Multiplication-Sign 2) for a total dose of 24 Gy, delivered within 1 day. The dose was subsequently increased to 27 Gy (13.5 Gy Multiplication-Sign 2) delivered in 1 day. We report the acute and early chronic genitourinary and gastrointestinal toxicity. Methods and Materials: A total of 173 patients were treated between December 2005 and July 2010. However, only the first 100 were part of the IRB-approved study and out of these, only 94 had a minimal follow-up of 6 months, representing the study population for this preliminary report. All patients had clinical Stage T2b or less (American Joint Committee on Cancer, 5th edition), Gleason score 6-7 (3+4), and prostate-specific antigen level of {<=}12 ng/mL. Ultrasound-guided HDR-BT with real-time dosimetry was used. The prescription dose was 24 Gy for the first 50 patients and 27 Gy thereafter. The dosimetric goals and constraints were the same for the two dose groups. Toxicity was scored using the National Cancer Institute Common Terminology Criteria for Adverse Events, version 3. The highest toxicity scores encountered at any point during follow-up are reported. Results: The median follow-up was 17 months (range, 6-40.5). Most patients had Grade 0-1 acute toxicity. The Grade 2 acute genitourinary toxicity was mainly frequency/urgency (13%), dysuria (5%), hematuria, and dribbling/hesitancy (2%). None of the patients required a Foley catheter at any time; however, 8% of the patients experienced transient Grade 1 diarrhea. No other acute gastrointestinal toxicities were found. The most common chronic toxicity was Grade 2 urinary frequency/urgency in 16% of patients followed by dysuria in 4% of patients; 2 patients had Grade 2 rectal bleeding and 1 had Grade 4, requiring laser treatment. Conclusions: Favorable-risk prostate cancer patients treated with a single implant HDR-BT to 24-27 Gy in two fractions within 1 day have excellent tolerance with minimal acute and chronic toxicity. Longer follow-up is needed to confirm these encouraging early results.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Brachial Plexus-Associated Neuropathy After High-Dose Radiation Therapy for Head-and-Neck Cancer

Purpose: To identify clinical and treatment-related predictors of brachial plexus-associated neuropathies after radiation therapy for head-and-neck cancer. Methods and Materials: Three hundred thirty patients who had previously completed radiation therapy for head-and-neck cancer were prospectively screened using a standardized instrument for symptoms of neuropathy thought to be related to brachial plexus injury. All patients were disease-free at the time of screening. The median time from completion of radiation therapy was 56 months (range, 6-135 months). One-hundred fifty-five patients (47%) were treated by definitive radiation therapy, and 175 (53%) were treated postoperatively. Radiation doses ranged from 50 to 74 Gy (median, 66 Gy). Intensity-modulated radiation therapy was used in 62% of cases, and 133 patients (40%) received concurrent chemotherapy. Results: Forty patients (12%) reported neuropathic symptoms, with the most common being ipsilateral pain (50%), numbness/tingling (40%), motor weakness, and/or muscle atrophy (25%). When patients with <5 years of follow-up were excluded, the rate of positive symptoms increased to 22%. On univariate analysis, the following factors were significantly associated with brachial plexus symptoms: prior neck dissection (p = 0.01), concurrent chemotherapy (p = 0.01), and radiation maximum dose (p < 0.001). Cox regression analysis confirmed that both neck dissection (p < 0.001) and radiation maximum dose (p < 0.001) were independently predictive of symptoms. Conclusion: The incidence of brachial plexus-associated neuropathies after radiation therapy for head-and-neck cancer may be underreported. In view of the dose-response relationship identified, limiting radiation dose to the brachial plexus should be considered when possible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Salvage Radiation Therapy Dose Response for Biochemical Failure of Prostate Cancer After Prostatectomy—A Multi-Institutional Observational Study

Purpose: To determine whether a dose-response relationship exists for salvage radiation therapy (RT) of biochemical failure after prostatectomy for prostate cancer. Methods and Materials: Individual data from 1108 patients who underwent salvage RT at 10 academic centers were pooled. The cohort was enriched for selection criteria more likely associated with tumor recurrence in the prostate bed (margin positive and pre-RT prostate-specific antigen [PSA] level of ≤2.0 ng/mL) and without the confounding of planned androgen suppression. The cumulative incidence of biochemical failure and distant metastasis over time was computed, and competing risks hazard regression models were used to investigate the association between potential predictors and these outcomes. The association of radiation dose with outcomes was the primary focus. Results: With a 65.2-month follow-up duration, the 5- and 10-year estimates of freedom from post-RT biochemical failure (PSA level >0.2 ng/mL and rising) was 63.5% and 49.8%, respectively, and the cumulative incidence of distant metastasis was 12.4% by 10 years. A Gleason score of ≥7, higher pre-RT PSA level, extraprostatic tumor extension, and seminal vesicle invasion were associated with worse biochemical failure and distant metastasis outcomes. A salvage radiation dose of ≥66.0 Gy was associated with a reduced cumulative incidence of biochemical failure, but not of distant metastasis. Conclusions: The use of salvage radiation doses of ≥66.0 Gy are supported by evidence presented in the present multicenter pooled analysis of individual patient data. The observational reporting method, limited sample size, few distant metastasis events, modest follow-up duration, and elective use of salvage therapy might have diminished the opportunity to identify an association between the radiation dose and this endpoint.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fading study of Harshaw LiF:Mg,Ti thermoluminescence dosimeters exposed to neutron doses

Sensitivity and signal fading were tested in Harshaw LiF:Mg,Ti thermoluminescence dosimeters (TLDs) exposed to neutron and beta/photons doses. A significant difference in the signal fading rate was observed for TLDs exposed to neutrons compared with TLDs exposed to betas. This difference may have been related to differences in glow curves for dosimeters exposed to different beams and to differences in glow curve evolution after exposure. A fading-correction algorithm was developed to correct the cumulative sensitivity + signal fading of TL doses for the fading time t using the formulae: y = 0.147∗exp(-t/4.36) + 0.308∗exp(-t/34.1) + 0.73 for neutrons, and: y = 0.132∗exp(-t/10.72) + 0.174∗exp(-t/31.5) + 0.8 for betas/photons. The formula was validated using the dose recovery test, where the average deviation of fading-corrected doses from delivery doses was within 1%. In conclusion, the proposed fading-correction approaches may significantly improve the accuracy of Harshaw TL dosimetry with LiF:Mg,Ti cards for both neutron and beta/gamma irradiation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Refine your search to explore more results.