Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DETECTOR PHYSICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Measurement of the sodium and iodine scintillation quenching factors across multiple NaI(Tl) detectors to identify systematics

The amount of light produced by nuclear recoils in scintillating targets is strongly quenched compared to that produced by electrons. A precise understanding of the quenching factor is particularly interesting for weakly interacting massive particles (WIMP) searches and coherent elastic neutrino-nucleus scattering ( CE ν NS ) measurements since both rely on nuclear recoils, whereas energy calibrations are more readily accessible from electron recoils. There is a wide variation among the current measurements of the quenching factor in sodium iodide (NaI) crystals, especially below 10 keV, the energy region of interest for dark matter and CE ν NS studies. A better understanding of the quenching factor in NaI(Tl) is of particular interest for resolving the decades-old puzzle in the field of dark matter between the null results of most WIMP searches and the claim for dark matter detection by the DAMA/LIBRA collaboration. In this work, we measured sodium and iodine quenching factors for five small NaI(Tl) crystals grown with similar thallium concentrations and growth procedures. Unlike previous experiments, multiple crystals were tested, with measurements made in the same experimental setup to control systematic effects. The quenching factors agree in all crystals we investigated, and both sodium and iodine quenching factors are smaller than those reported by DAMA/LIBRA. The dominant systematic effect was due to the electron equivalent energy calibration originating from the nonproportional behavior of the NaI(Tl) light yield at lower energies, potentially the cause for the discrepancies among the previous measurements. Published by the American Physical Society 2024

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Discriminating between a stochastic gravitational wave background and instrument noise

The detection of a stochastic background of gravitational waves could significantly impact our understanding of the physical processes that shaped the early Universe. The challenge lies in separating the cosmological signal from other stochastic processes such as instrument noise and astrophysical foregrounds. One approach is to build two or more detectors and cross correlate their output, thereby enhancing the common gravitational wave signal relative to the uncorrelated instrument noise. When only one detector is available, as will likely be the case with the Laser Interferometer Space Antenna (LISA), alternative analysis techniques must be developed. Here we show that models of the noise and signal transfer functions can be used to tease apart the gravitational and instrument noise contributions. We discuss the role of gravitational wave insensitive ''null channels'' formed from particular combinations of the time delay interferometry, and derive a new combination that maintains this insensitivity for unequal arm-length detectors. We show that, in the absence of astrophysical foregrounds, LISA could detect signals with energy densities as low as {Omega}{sub gw}=6x10{sup -13} with just one month of data. We describe an end-to-end Bayesian analysis pipeline that is able to search for, characterize and assign confidence levels for the detection of a stochastic gravitational wave background, and demonstrate the effectiveness of this approach using simulated data from the third round of Mock LISA Data Challenges.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Latest Electroweak Results from CDF

The latest results in electroweak physics from proton anti-proton collisions at the Fermilab Tevatron recorded by the CDF detector are presented. The results provide constraints on parton distribution functions, the mass of the Higgs boson and beyond the Standard Model physics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Top Quark Mass in the Dilepton and Alljets Channels

Recent measurements of the top quark mass in the dilepton (t{bar t} to {bar b} {ell}{sup -} {bar {nu}}{ell}b {ell}{sup '+} {nu}{sub {ell}}{sup '}) and alljets (t{bar t} to b{bar b}q {bar q}'q' {bar q}$) decay channels from the CDF and D0 collaborations are presented. These decay channels provide unique challenges from the lepton+jets decay channel. Results utilizing up to 2.8 fb{sup -1} of p{bar p} collider data from the Fermilab Tevatron are discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurements of Rare B Decays at Tevatron

Both CDF and D0 experiments have been searching for evidence of physics beyond the standard model (SM) using the Tevatron p{bar p} collider at Fermilab. We report on recent searches in the B flavor sector, especially decays via flavor changing neutral current processes (FCNC), B{sub (s)}{sup 0} {yields} e{sup +}{mu}{sup -} and B{sub s}{sup 0} {yields} {mu}{sup +}{mu}{sup -}, at the Tevatron.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Thermodynamic stability of xenon-doped liquid argon detectors

Liquid argon detectors are employed in a wide variety of nuclear and particle physics experiments. The addition of small quantities of xenon to argon modifies its scintillation, ionization, and electroluminescence properties and can improve its performance as a detection medium. However, a liquid argon-xenon mixture can develop instabilities, especially in systems that require phase transitions or that utilize high xenon concentrations. In this work, we analyze the causes of these instabilities and describe a small (liter-scale) apparatus with a unique cryogenic circuit specifically designed to handle argon-xenon mixtures. The system is capable of condensing argon gas mixed with $\mathscr{O}$ (1%) xenon by volume and maintains a stable liquid mixture near the xenon saturation limit while actively circulating it in the gas phase. We also demonstrate control over instabilities that develop when the detector condition is allowed to deviate from optimized settings. This progress enables future liquid argon detectors to benefit from the effects of high concentrations of xenon doping, such as more efficient detection of low-energy ionization signals. In conclusion, this work also develops tools to study and mitigate instabilities in large argon detectors that use low concentration xenon doping.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ultra-high energy neutrino fluxes as a probe for non-standard physics

We examine how light neutrinos coming from distant active galactic nuclei (AGN) and similar high energy sources may be used as tools to probe non-standard physics. In particular we discuss how studying the energy spectra of each neutrino flavour coming from such distant sources and their distortion relative to each other may serve as pointers to exotic physics such as neutrino decay, Lorentz symmetry violation, pseudo-Dirac effects, CP and CPT violation and quantum decoherence. This allows us to probe hitherto unexplored ranges of parameters for the above cases, for example lifetimes in the range 10{sup −3}−10{sup 4} s/eV for the case of neutrino decay. We show that standard neutrino oscillations ensure that the different flavours arrive at the earth with similar shapes even if their flavour spectra at source may differ strongly in both shape and magnitude. As a result, observed differences between the spectra of various flavours at the detector would be signatures of non-standard physics altering neutrino fluxes during propagation rather than those arising during their production at source. Since detection of ultra-high energy (UHE) neutrinos is perhaps imminent, it is possible that such differences in spectral shapes will be tested in neutrino detectors in the near future. To that end, using the IceCube detector as an example, we show how our results translate to observable shower and muon-track event rates.

79 ASTRONOMY AND ASTROPHYSICS↗

The MAGNEX large acceptance spectrometer

The main features of the MAGNEX large acceptance magnetic spectrometer are described. It has a quadrupole + dipole layout and a hybrid detector located at the focal plane. The aberrations due to the large angular (50 msr) and momentum (+- 13%) acceptance are reduced by an accurate hardware design and then compensated by an innovative software ray-reconstruction technique. The obtained resolution in energy, angle and mass are presented in the paper. MAGNEX has been used up to now for different experiments in nuclear physics and astrophysics confirming to be a multipurpose device.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutrinos and Dark Matter Across Energies and Epochs (Final Technical Report)

The opportunities afforded by upcoming next-generation neutrino experiments offer new physics potential that is complementary to high-energy collider searches. Although much lower in energy, the combination of large detectors and high intensity proton beams yields novel sensitivity to new physics. The types of new physics signals include both those which are terrestrially sourced as well as astrophysically produced. Within this project specific focuses include: (1) BSM searches at neutrino and dark matter experiments to look for axion-like particles, heavy neutrinos, and new force carriers; and (2) BSM signals from astrophysics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Exploring the Energy Frontier through Precision Tests and Fast Tracking with the CMS Detector (Final Technical Report)

This Early Career Award supported a research program using the CMS experiment at the CERN LHC to probe physics beyond the Standard Model in the top quark and Higgs boson sectors, alongside detector and trigger developments for the High-Luminosity LHC (HL-LHC) upgrade. The program (i) searched for charged lepton flavor violation (LFV) in the top quark sector with the full CMS Run-2 data set, placing the world’s strongest limits to date on the $t → eµq\ (q = u/c)$ branching fraction; (ii) developed preliminary analysis methods toward a boosted $t\bar{t}H(b\bar{b})$ measurement of the top quark Yukawa coupling and its CP properties; (iii) made leading contributions to the hardware-based Level-1 (L1) track finding system for the upgraded CMS detector for HL-LHC; and (iv) developed novel L1 trigger algorithms, notably a displaced vertex trigger enabling new searches for exotic long-lived particles.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Status of the MEG Experiment

The MEG experiment which searches for {mu}{yields}e{gamma} decays at the sensitivity level of 10{sup -13} is now in its final stage of the preparation. Some data run is expected by the end of the year 2007. The statuses of each detector components are described.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Detecting Diffraction at the LHC

Forward spectrometers and leading proton detectors--when combined with the powerful mainstream experiments at the LHC--will open up unparalleled physics opportunities in detecting complete high energy collision events in extreme conditions. The range of physics that will be accessed is huge: the small angle extensions of the ATLAS and CMS will effectively transform the LHC into a laboratory of gluon jets, deeply inelastic scattering and novel phenomena not accessed so far in any other experiment. A rapidity gap physics program of a superb potential can be realized at the LHC by adding a few simple forward shower counters (FSCs) along the beam line on both sides of the CMS detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Status of the muon neutrino charged-current zero mesons cross section measurement in the NOvA near detector

NOvA is a long-baseline accelerator neutrino experiment at Fermilab whose physics goals include precision neutrino oscillation as well as cross-section measurements. We present the status of the measurement of muon neutrino charged-current cross section with zero mesons in the final state at the NOvA near detector. This measurement will be made with respect to the kinematics of the final state particles. Our chosen interaction channel is especially sensitive to quasielastic and meson exchange current interactions and will provide a handle for constraining the cross section systematic uncertainties in oscillation analyses in current and future experiments. For particle identification, we use a convolutional neural network (CNN) trained on individual particles simulated in the NOvA near detector that allows us to select the desired signal while reducing the potential bias from neutrino interaction modeling. Charged pion background constraining is further improved via Michel electron tagging.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Recent Activities and Perspectives at MAMI

In 2007, the fourth accelerator stage (MAMI-C) has gone into operation at Mainz increasing the electron energy from 855 MeV to 1.5 GeV. High-intensity polarized electron and photon beams, polarized targets and recoil polarimeters in combination with dedicated detectors are available for precision experiments in hadron physics. In this talk, an overview over selected recent results and future plans will be given.

43 PARTICLE ACCELERATORS↗

Detector Developments for the High Luminosity LHC Era (3/4)

Tracking Detectors - Part I. Calorimetry, muon detection, vertexing, and tracking will play a central role in determining the physics reach for the High Luminosity LHC Era. In these lectures we will cover the requirements, options, and the R&D; efforts necessary to upgrade the current LHC detectors and enabling discoveries.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performance of the CMS high-level trigger during LHC Run 2

The CERN LHC provided proton and heavy ion collisions during its Run 2 operation period from 2015 to 2018. Proton-proton collisions reached a peak instantaneous luminosity of 2.1× 10 34 cm -2 s -1 , twice the initial design value, at √(s)=13 TeV. The CMS experiment records a subset of the collisions for further processing as part of its online selection of data for physics analyses, using a two-level trigger system: the Level-1 trigger, implemented in custom-designed electronics, and the high-level trigger, a streamlined version of the offline reconstruction software running on a large computer farm. This paper presents the performance of the CMS high-level trigger system during LHC Run 2 for physics objects, such as leptons, jets, and missing transverse momentum, which meet the broad needs of the CMS physics program and the challenge of the evolving LHC and detector conditions. Sophisticated algorithms that were originally used in offline reconstruction were deployed online. Highlights include a machine-learning b tagging algorithm and a reconstruction algorithm for tau leptons that decay hadronically.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-I-86: Evaluation of the New RaySafe Unfors X2 Dosimetry System

Purpose: To evaluate the new RaySafe Unfors X2 (X2) dosimetry system and compare it to the operation of the RaySafe Unfors Xi (Xi) and Radcal Accugold (RCAG) dosimetry systems. The comparison was done for the radiographic/fluoroscopic detectors, mammography detectors and the CT ionization chambers. Methods: This study used several R/F rooms, GE AMX4 portable x-ray unit, Siemens Biograph 16 slice CT scanner and a Hologic Dimensions mammography unit to evaluate the dosimetry systems. The three X2 detectors were compared to similar detectors of the older Xi and RCAG detectors under clinical conditions used for diagnostic medical physics testing. Measurements of kVp, HVL and exposure were made under identical conditions. Results: For radiography and fluoroscopy the three systems agreed to within +2 kVp in the 60 to 140 kVp range, HVL measurements agreed to within +2 mm Al and the exposures agreed to within +5%. The RCAG 6 cc ionization chamber measured at least 3% higher than the diode systems. The X2 R/F detector appeared to be transparent to the fluoroscopy AEC system. For exposures made using both the CT ACR dose phantoms, the X2 agreed to within +3% of the other two systems. For mammography measurements, the three systems agreed to within +0.4kVp (25-49 kVp range), HVL measurements agreed to within +0.05 mm Al and the exposures agreed to within +1% of the ionization chamber. Conclusion: The X2 system is a new version of the older Xi system. The system is faster, more robust, very easy to use, has a larger dynamic range, produced less errors and stores 1000 exposures. The measurements showed that the system performs well in the clinical environment and the X2 is within + 5% agreement of the other two calibrated systems.

60 APPLIED LIFE SCIENCES↗

Violation of multipartite Bell inequalities with classical subsystems via operationally local transformations

Recently, it was demonstrated by Son et al., Phys. Rev. Lett. 102, 110404 (2009), that a separable bipartite continuous-variable quantum system can violate the Clauser-Horne-Shimony-Holt (CHSH) inequality via operationally local transformations. Operationally local transformations are parametrized only by local variables; however, in order to allow violation of the CHSH inequality, a maximally entangled ancilla was necessary. The use of the entangled ancilla in this scheme caused the state under test to become dependent on the measurement choice one uses to calculate the CHSH inequality, thus violating one of the assumptions used in deriving a Bell inequality, namely, the free will or statistical independence assumption. The novelty in this scheme however is that the measurement settings can be external free parameters. In this paper, we generalize these operationally local transformations for multipartite Bell inequalities (with dichotomic observables) and provide necessary and sufficient conditions for violation within this scheme. Namely, a violation of a multipartite Bell inequality in this setting is contingent on whether an ancillary system admits any realistic local hidden variable model (i.e., whether the ancilla violates the given Bell inequality). These results indicate that violation of a Bell inequality performed on a system does not necessarily imply that the system is nonlocal. In fact, the system under test may be completely classical. However, nonlocality must have resided somewhere, this may have been in the environment, the physical variables used to manipulate the system or the detectors themselves provided the measurement settings are external free variables.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Refine your search to explore more results.