Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Curve fitting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Performance Assessment of a New Gamma Spectroscopy Toolkit: Peak Doctor and the Spectral Nondestructive Assay Platform (SNAP) - 17397

High resolution gamma spectroscopy (HRGS) is a widely used technique for non-destructive characterization of nuclear materials, and assay of radioactive waste. The ability to accurately evaluate raw spectral data is an important step in producing high-quality results. A spectral analysis application known as Peak Doctor has been developed under a Cooperative Research and Development Agreement (CRADA) between LANL and Pajarito Scientific Corporation (PSC). The software has undergone several years of testing and validation by the Radioactive Waste Characterization Team of the LANL Waste Management Services Group (WM-SVS). PeakDoctor is designed to work with the Spectral Nondestructive Assay Platform (SNAP{sup TM}) to provide a complete HRGS analysis engine. SNAP{sup TM} performs model specific corrections for attenuation and geometry. These applications are the major components of a new toolkit designed primarily for portable far-field non-destructive assay. Peak Doctor performs a very accurate peak fit analysis with the goal of improving upon the capabilities of existing commercially available routines. It is designed to be user-configurable and can be customized to any given type of detector and any given type of spectrum. Peak Doctor was developed to resolve many of the inherent complexities in gamma ray spectra including overlapping peaks, complex multiplet regions, large step peaks, backscatter regions and Compton edges. Unlike most spectral analysis platforms, Peak Doctor does not rely on the energy calibration and detector resolution parameters that are saved by the operator in the spectrum file. Instead, key parameters are pre-defined for individual detectors. The software fits a continuum using a series of splines between a series of junctions or 'knots'. Fitting techniques are used to join the splines together to create a near-continuous multi-element curve. Optimizing the location of the knots is one of Peak Doctor's most powerful features. The knots are initially configured using a pre-defined list and are removed or added automatically during the fitting process. Knots are also created when new features are identified such as Step Peaks and Compton Edges. The user can also manually specify knots in order to improve the continuum fit. The initial fit is improved on by removing any outlier regions (which are converted to peaks) and the continuum fitting process is repeated. At this stage, an experienced user can work interactively with the fit by manually converting peak regions to continuum or vice versa. The final step is to fit a series of peaks above the continuum based on detector parameters. Single and multiplet peaks are then processed by either the tailing (piecewise) or non-tailing (Gaussian) Levenberg Marquardt non-linear peak fitting routine depending on the user defined selection. Only a rough knowledge of the detector characteristics (energy calibration and resolution) is required for the fitting process to proceed with good accuracy. Any peaks that are missed can be manually added by the user and will also be fitted. Discontinuities in the peak / continuum fit can be rapidly identified by reviewing the 'residuals scale' plot. For waste streams that are well characterized, it is often the case that routinely encountered spectra will have similar peaks and continuum features. For these cases a handy 'One Step' method is available that proceeds in an automated fashion without user interaction. Peak Doctor has been configured with a set of default spectrum types including plutonium / transuranic waste (including Weapons Grade Pu, Heat Source Pu, Am-241, Am-243 and Np-237), depleted or enriched uranium, nuclear power plant / intermediate level waste (with fission and activation products such as Cs-137 and Co-60) as well as Naturally Occurring Radioactive Materials (NORM). The user can easily add new spectrum types for specific waste streams or other types of radiological / special nuclear materials. The output from PeakDoctor (including net peak area, centroid energy and a list of minimum detectable activity levels at pre-defined regions) is used by SNAP{sup TM} to complete the data analysis process. Isotope activities are calculated using configurable template-driven geometry and attenuation correction methods. The software accounts for matrix and container wall effects, collimator / angular corrections, detector efficiency (based on calibration curves) and stand-off distance. SNAP{sup TM} uses published algorithms incorporating a series of decision points during its operation to allow the analyst to provide logical input to guide the software during the analysis of each unique spectrum. The Peak Doctor / SNAP{sup TM} toolkit has been extensively tested and validated under a variety of conditions using 'benchmark' reference spectra. Test scenarios reported include HPGe-based measurements of well characterized uranium and plutonium standards and radioactive sources with a variety of different geometries and matrix materials including surrogate drums and boxes. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Minkowski Functionals of SDSS-III BOSS: Hints of Possible Anisotropy in the Density Field?

We present measurements of the Minkowski functionals extracted from the SDSS-III BOSS catalogs. After defining the Minkowski functionals, we describe how an unbiased reconstruction of these statistics can be obtained from a field with masked regions and survey boundaries, validating our methodology with Gaussian random fields and mock galaxy snapshot data. From the BOSS galaxy data, we generate a set of four density fields in three dimensions corresponding to the northern and southern skies of LOWZ and CMASS catalogs, smoothing over large scales (Gaussian smoothing scale of 35 Mpc) such that the field is perturbatively non-Gaussian. We extract the Minkowski functionals from each data set separately, and measure their shapes and amplitudes by fitting a Hermite polynomial expansion. For the shape parameter of the Minkowski functional curves a0, that is related to the bispectrum of the field, we find that the LOWZ-South data presents a systematically lower value of a 0 = –0.080 ± 0.040 than its northern sky counterpart a 0 = 0.032 ± 0.024. Although the significance of this discrepancy is not very high, it potentially indicates some systematics in the data or that the matter density field exhibits anisotropy at low redshift. By assuming a standard isotropic flat ΛCDM cosmology, the amplitudes of the Minkowski functionals from the combination of northern and southern sky data give the constraints Ω c h 2 n s = 0.110 ± 0.006 and 0.111 ± 0.008 for CMASS and LOWZ, respectively, which is in agreement with the Planck ΛCDM best-fit Ω c h 2 n s = 0.116 ± 0.001.

79 ASTRONOMY AND ASTROPHYSICS↗

An asymmetric outgassing model for cometary nongravitational accelerations

The standard nongravitation force model has been modified by allowing the water-vaproization curve to peak a certain number of days (DT) either before or after perihelion, and the modification is shown to often improve the data fit. The best fit to the astrometric data is generally achieved for a value of DT corresponding to the offset in the comet's visual light curve. The asymmetric model, which more accurately mimics the comet's outgassing history, suggests only weakly that the rotation direction of Comet Halley is direct, and it does not provide evidence that the rotation axis of Comet Kopff passed through its orbit plane in the early twentieth century. Approximate lag angles of 4 deg for Comet Halley and 10 deg for Comet d'Arrest are found using the asymmetric model, and it is noted that these values are lower than those obtained with the standard model.

Yeomans, D. K.↗

Au-Ag Alloy Static High Pressure EOS measurements: FY09 summary of results

Static high-pressure measurements of the equation of state of a Gold-Silver alloy (23.5 wt-% Ag) at room temperature were performed up to a pressure of approximately 100 GPA (1 megabar). Measurements were made using an energy-dispersive x-ray diffraction method. The data was analyzed, yielding crystal structure lattice constants and volume/density as a function of pressure. The results are extremely precise yielding accuracy of better than 1%. The experiments were carried out at the HPCAT 16BM-D beamline at the Advanced Photon Source. Two experiments on separate samples were carried out using conventional membrane diamond anvil cells. To achieve hydrostatic conditions, we loaded a 50-100 micron piece of the Au-Ag alloy into the cell and surrounded it with neon and mineral oil pressure media in the respective experiments. The differing pressure media demonstrated no measurable difference on the resultant crystal structures, lattice constants or pressure-volume curves. Results of our work are shown in the figures below. Up to the maximum pressure of 100 GPa the sample remained in the face-centered cubic structure, e.g., we observed no change in crystal structure. EOS curves of silver and gold, taken from the literature, are shown for comparison. We fit our data to a Vinet EOS functional form, and the parameters for this EOS were found to be, Reference (ambient pressure) volume, V{sub 0} = 16.965435 {angstrom}{sup 3}; Reference (ambient pressure) density, {rho}{sub 0} = 16.14584 g/cm{sup 3}; Bulk Modulus, K{sub 0} = 144 GPa; and Bulk Mod Derivative, K{prime}{sub 0} = 5.66. As one might expect the Au-Ag alloy lies between the gold and silver EOS curves, and tracks more closely to the gold EOS. These data are useful in validating and developing predictive EOS models of the pressure-dependent behavior of Au-Ag alloys.

36 MATERIALS SCIENCE↗

Some implications of linear-quadratic-linear radiation dose-response with regard to hypofractionation

Recent technological advances enable radiation therapy to be delivered in a highly conformal manner to targets located almost anywhere in the body. This capability has renewed the clinical interest in hypofractionation wherein the tumor is delivered a few fractions of very large dose per fraction. Extrapolating clinical experience from conventional regimens to fractions of high dose is important to designing hypofractionated treatments. The concept of biologically effective dose (BED) based on the linear-quadratic (LQ) formulation e{sup -({alpha}D+{beta}D{sup 2})} is a useful tool for intercomparing conventional fractionations but may be hampered if the value of {alpha}/{beta} is dose range dependent and/or when extrapolating to fractions of high dose because the LQ curve bends continuously on the log-linear plot. This does not coincide with what is observed experimentally in many clonogenic cell survival studies at high dose wherein radiation dose-response relationships more closely approximate a straight line. Intercomparison of conventional fractionations with hypofractionated regimens may benefit from BED calculations which instead use a dose range independent linear-quadratic-linear (LQ-L) formulation which better fits the experimental data across a wider range of dose. The dosimetric implications of LQ-L are explored using a simple model which requires only the specification of a dose D{sub T} at which the LQ curve transitions to final linearity and the log{sub e} cell kill per Gy in the final linear portion of the survival curve at high dose. It is shown that the line tangent to the LQ curve at transition dose D{sub T} can often be used to approximate the final slope of the dose response curve. When D{sub T}=2{alpha}/{beta} Gy, the line tangent to the LQ curve at D{sub T} intersects the e{sup -{alpha}}{sup D} and e{sup -{beta}}{sup D{sup 2}} curves at dose {alpha}/{beta} Gy and also closely fits the linear response in the high dose region of some classic in vitro cell survival curves for which the value of {alpha}/{beta} is low. It is hypothesized that D{sub T} will increase as the magnitude of {alpha}/{beta} increases. Examples are presented illustrating how to recognize LQ-L behavior in multifraction isoeffect studies of late responses such as spinal cord and lung. When planning hypofractionated regimens involving reactions with low {alpha}/{beta}, recognizing LQ-L behavior could be important because the dose-response is likely to transition to final linearity within the contemplated range of hypofractional doses.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An hourglass model for the flare of HST-1 in M87

To explain the multi-wavelength light curves (from radio to X-ray) of HST-1 in the M87 jet, we propose an hourglass model that is a modified two-zone system of Tavecchio and Ghisellini (hereafter TG08): a slow hourglass-shaped or Laval-nozzle-shaped layer connected by two revolving exponential surfaces surrounding a fast spine through which plasma blobs flow. Based on the conservation of magnetic flux, the magnetic field changes along the axis of the hourglass. We adopt the result of TG08—the high-energy emission from GeV to TeV can be produced through inverse Compton by the two-zone system, and the photons from radio to X-ray are mainly radiated by the fast inner zone system. Here, we only discuss the light curves of the fast inner blob from radio to X-ray. When a compressible blob travels down the axis of the first bulb in the hourglass, because of magnetic flux conservation, its cross section experiences an adiabatic compression process, which results in particle acceleration and the brightening of HST-1. When the blob moves into the second bulb of the hourglass, because of magnetic flux conservation, the dimming of the knot occurs along with an adiabatic expansion of its cross section. A similar broken exponential function could fit the TeV peaks in M87, which may imply a correlation between the TeV flares of M87 and the light curves from radio to X-ray in HST-1. The Very Large Array (VLA) 22 GHz radio light curve of HST-1 verifies our prediction based on the model fit to the main peak of the VLA 15 GHz radio one.

79 ASTRONOMY AND ASTROPHYSICS↗

DISCOVERY OF PRECURSOR LUMINOUS BLUE VARIABLE OUTBURSTS IN TWO RECENT OPTICAL TRANSIENTS: THE FITFULLY VARIABLE MISSING LINKS UGC 2773-OT AND SN 2009ip

We present progenitor-star detections, light curves, and optical spectra of supernova (SN) 2009ip and the 2009 optical transient in UGC 2773 (U2773-OT), which were not genuine SNe. Precursor variability in the decade before outburst indicates that both of the progenitor stars were luminous blue variables (LBVs). Their pre-outburst light curves resemble the S Doradus phases that preceded giant eruptions of the prototypical LBVs {eta} Carinae and SN 1954J (V12 in NGC 2403), with intermediate progenitor luminosities. Hubble Space Telescope detections a decade before discovery indicate that the SN 2009ip and U2773-OT progenitors were supergiants with likely initial masses of 50-80 M {sub sun} and {approx}>20 M {sub sun}, respectively. Both outbursts had spectra befitting known LBVs, although in different physical states. SN 2009ip exhibited a hot LBV spectrum with characteristic speeds of 550 km s{sup -1}, plus evidence for faster material up to 5000 km s{sup -1}, resembling the slow Homunculus and fast blast wave of {eta} Carinae. In contrast, U2773-OT shows a forest of narrow absorption and emission lines comparable to that of S Dor in its cool state, plus [Ca II] emission and an infrared excess indicative of dust, similar to SN 2008S and the 2008 optical transient in NGC 300 (N300-OT). The [Ca II] emission is probably tied to a dusty pre-outburst environment, and is not a distinguishing property of the outburst mechanism. The LBV nature of SN 2009ip and U2773-OT may provide a critical link between historical LBV eruptions, while U2773-OT may provide a link between LBVs and the unusual dust-obscured transients SN 2008S and N300-OT. Future searches will uncover more examples of precursor LBV variability of this kind, providing key clues that may help unravel the instability driving LBV eruptions in massive stars.

79 ASTRONOMY AND ASTROPHYSICS↗

A SIRTF interdiciplinary scientist proposal

Segal's chronometric cosmology provides an adequate fit to the radio source counts only for an unrealistic choice of spectral index. Since the typical observed spectral index of 0.75 gives a completely unacceptable X squared = 136 with 24 (or fewer) degrees of freedom, it is concluded that the actual Universe does not fit the chronometric model. Counts of ultraviolet excess quasistellar objects also show a steep N(S) curve that the chronometric cosmology cannot explain. Claims to the contrary by Segal, Loncaric, and Segal (1980) and Segal and Nicoll (1986) depend on a seemingly innocuous assumption that in fact destroys the power of the N(S) test. Even though the chronometric model gives a better fit that other non-evolving models it must be ruled out along with all non-evolving cosmologies.

Wright, E. L.↗

Determination of the mechanical properties of blisters by nanoindentation

In light-water reactors, a zirconium oxide layer will be formed at the outer surface of the fuel cladding as a consequence of the chemical reaction which takes place between zirconium and the cooling water. This zirconium oxide layer is a good thermal insulator, but at some point, it may spall-out. As a consequence, a cold spot will be formed at the outer surface of the cladding. In this situation, the hydrogen will quickly migrate to this spot to form a highly-enriched hydride zone, known as blister. In this work, an experimental procedure has been devised to produce blisters with a similar shape to the ones reported in the literature for irradiated cladding with severe hydriding. Nano-indentation tests were performed on blisters prepared in laboratory. A numerical simulation by the finite element method was developed to fit the load versus penetration depth data from the aforementioned nano-indentation tests. By means of an inverse process which combines experimental data and numerical simulations, the constitutive equation of the blister was determined. The process has been used to calculate the plastic stress-strain curve of the blister under study at room temperature. The results show an almost perfect numerical fitting of the experimental data.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Probabilities of Radiation Myelopathy Specific to Stereotactic Body Radiation Therapy to Guide Safe Practice

Purpose: Dose-volume histogram (DVH) results for 9 cases of post spine stereotactic body radiation therapy (SBRT) radiation myelopathy (RM) are reported and compared with a cohort of 66 spine SBRT patients without RM. Methods and Materials: DVH data were centrally analyzed according to the thecal sac point maximum (Pmax) volume, 0.1- to 1-cc volumes in increments of 0.1 cc, and to the 2 cc volume. 2-Gy biologically equivalent doses (nBED) were calculated using an {alpha}/{beta} = 2 Gy (units = Gy{sub 2/2}). For the 2 cohorts, the nBED means and distributions were compared using the t test and Mann-Whitney test, respectively. Significance (P<.05) was defined as concordance of both tests at each specified volume. A logistic regression model was developed to estimate the probability of RM using the dose distribution for a given volume. Results: Significant differences in both the means and distributions at the Pmax and up to the 0.8-cc volume were observed. Concordant significance was greatest for the Pmax volume. At the Pmax volume the fit of the logistic regression model, summarized by the area under the curve, was 0.87. A risk of RM of 5% or less was observed when limiting the thecal sac Pmax volume doses to 12.4 Gy in a single fraction, 17.0 Gy in 2 fractions, 20.3 Gy in 3 fractions, 23.0 Gy in 4 fractions, and 25.3 Gy in 5 fractions. Conclusion: We report the first logistic regression model yielding estimates for the probability of human RM specific to SBRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Proposal for Universality in the Viscosity of Metallic Liquids

The range of magnitude of the liquid viscosity, η, as a function of temperature is one of the most impressive of any physical property, changing by approximately 17 orders of magnitude from its extrapolated value at infinite temperature (η o ) to that at the glass transition temperature, T g . We present experimental measurements of containerlessly processed metallic liquids that suggest that log(η/η o ) as a function of T A /T is a potentially universal scaled curve. In stark contrast to previous approaches, the scaling requires only two fitting parameters, which are on average predictable. The temperature T A corresponds to the onset of cooperative motion and is strongly correlated with T g , suggesting that the processes underlying the glass transition first appear in the high temperature liquid.

36 MATERIALS SCIENCE↗

Acoustic characterization of high intensity focused ultrasound fields generated from a transmitter with a large aperture

Prediction and measurement of the acoustic field emitted from a high intensity focused ultrasound (HIFU) is essential for the accurate ultrasonic treatment. In this study, the acoustic field generated from a strongly focused HIFU transmitter was characterized by a combined experiment and simulation method. The spheroidal beam equation (SBE) was utilized to describe the nonlinear sound propagation. The curve of the source pressure amplitude versus voltage excitation was determined by fitting the measured ratio of the second harmonic to the fundamental component of the focal waveform to the simulation result; finally, the acoustic pressure field generated by the strongly focused HIFU transmitter was predicted by using the SBE model. A commercial fiber optic probe hydrophone was utilized to measure the acoustic pressure field generated from a 1.1 MHz HIFU transmitter with a large half aperture angle of 30°. The maximum measured peak-to-peak pressure was up to 72 MPa. The validity of this combined approach was confirmed by the comparison between the measured results and the calculated ones. The results indicate that the current approach might be useful to describe the HIFU field. The results also suggest that this method is not valid for low excitations owing to low sensitivity of the second harmonic.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-Energy Delayed Gamma Spectroscopy for Spent Nuclear Fuel Assay

High-accuracy, direct, nondestructive measurement of fissile and fissionable isotopes in spent fuel, particularly the Pu isotopes, is a well-documented, but still unmet challenge in international safeguards. As nuclear fuel cycles propagate around the globe, the need for improved materials accountancy techniques for irradiated light-water reactor fuel will increase. This modeling study investigates the use of delayed gamma rays from fission-product nuclei to directly measure the relative concentrations of U-235, Pu-239, and Pu-241 in spent fuel assemblies. The method is based on the unique distribution of fission-product nuclei produced from fission in each of these fissile isotopes. Fission is stimulated in the assembly with a pulse-capable source of interrogating neutrons. The measured distributions of the short-lived fission products from the unknown sample are then fit with a linear combination of the known fission-product yield curves from pure U-235, Pu-239, and Pu-241 to determine the original proportions of these fissile isotopes. Modeling approaches for the intense gamma-ray background promulgated by the long-lived fission-product inventory and for the high-energy gamma-ray signatures emitted by short-lived fission products from induced fission are described. Benchmarking measurements are presented and compare favorably with the results of these models. Results for the simulated assay of simplified individual fuel elements ranging from fresh to 60 GWd/MTU burnup demonstrate the utility of the modeling methods for viability studies, although additional work is needed to more realistically assess the potential of High-Energy Delayed Gamma Spectroscopy (HEDGS).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

TU-C-12A-09: Modeling Pathologic Response of Locally Advanced Esophageal Cancer to Chemo-Radiotherapy Using Quantitative PET/CT Features, Clinical Parameters and Demographics

Purpose: To develop predictive models using quantitative PET/CT features for the evaluation of tumor response to neoadjuvant chemo-radiotherapy (CRT) in patients with locally advanced esophageal cancer. Methods: This study included 20 patients who underwent tri-modality therapy (CRT + surgery) and had {sup 18}F-FDG PET/CT scans before initiation of CRT and 4-6 weeks after completion of CRT but prior to surgery. Four groups of tumor features were examined: (1) conventional PET/CT response measures (SUVmax, tumor diameter, etc.); (2) clinical parameters (TNM stage, histology, etc.) and demographics; (3) spatial-temporal PET features, which characterize tumor SUV intensity distribution, spatial patterns, geometry, and associated changes resulting from CRT; and (4) all features combined. An optimal feature set was identified with recursive feature selection and cross-validations. Support vector machine (SVM) and logistic regression (LR) models were constructed for prediction of pathologic tumor response to CRT, using cross-validations to avoid model over-fitting. Prediction accuracy was assessed via area under the receiver operating characteristic curve (AUC), and precision was evaluated via confidence intervals (CIs) of AUC. Results: When applied to the 4 groups of tumor features, the LR model achieved AUCs (95% CI) of 0.57 (0.10), 0.73 (0.07), 0.90 (0.06), and 0.90 (0.06). The SVM model achieved AUCs (95% CI) of 0.56 (0.07), 0.60 (0.06), 0.94 (0.02), and 1.00 (no misclassifications). Using spatial-temporal PET features combined with conventional PET/CT measures and clinical parameters, the SVM model achieved very high accuracy (AUC 1.00) and precision (no misclassifications), significantly better than using conventional PET/CT measures or clinical parameters and demographics alone. For groups with a large number of tumor features (groups 3 and 4), the SVM model achieved significantly higher accuracy than the LR model. Conclusion: The SVM model using all features including quantitative PET/CT features accurately and precisely predicted pathologic tumor response to CRT in esophageal cancer. This work was supported in part by National Cancer Institute Grant R21 CA131979 and R01 CA172638. Shan Tan was supported in part by the National Natural Science Foundation of China 60971112 and 61375018, and by Fundamental Research Funds for the Central Universities 2012QN086.

60 APPLIED LIFE SCIENCES↗

HEAVY ION FUSION SCIENCE VIRTUAL NATIONAL LABORATORY2nd QUARTER 2010 MILESTONE REPORTDevelop the theory connecting pyrometer and streak camera spectrometer data to the material properties of beam heatedtargets and compare to the data

This milestone has been accomplished. We have extended the theory that connects pyrometer and streak spectrometer data to material temperature on several fronts and have compared theory to NDCX-I experiments. For the case of NDCX-I, the data suggests that as the metallic foils are heated they break into droplets (cf. HIFS VNL Milestone Report FY 2009 Q4). Evaporation of the metallic surface will occur, but optical emission should be directly observable from the solid or liquid surface of the foil or from droplets. However, the emissivity of hot material may be changed from the cold material and interference effects will alter the spectrum emitted from small droplets. These effects have been incorporated into a theory of emission from droplets. We have measured emission using streaked spectrometry and together with theory of emission from heated droplets have inferred the temperature of a gold foil heated by the NDCX-I experiment. The intensity measured by the spectrometer is proportional to the emissivity times the blackbody intensity at the temperature of the foil or droplets. Traditionally, a functional form for the emissivity as a function of wavelength (such as a quadratic) is assumed and the three unknown emissivity parameters (for the case of a quadratic) and the temperature are obtained by minimizing the deviations from the fit. In the case of the NDCX-I experiment, two minima were obtained: at 7200 K and 2400 K. The best fit was at 7200 K. However, when the actual measured emissivity of gold was used and when the theoretical corrections for droplet interference effects were made for emission from droplets having radii in the range 0.2 to 2.0 microns, the corrected emissivity was consistent with the 2400 K value, whereas the fit emissivity at 7200 K shows no similarity to the corrected emissivity curves. Further, an estimate of the temperature obtained from beam heating is consistent with the lower value. This exercise proved to be a warning to be skeptical of assuming functional forms when they are unknown, and also represents a first success of the droplet emission theory. The thermal optical emission from a hot metal surface is polarized (for observation angles that are not normal to the surface). By observing the intensity of both polarizations at two or more observation angles the emissivity can be inferred directly, and the temperature at the surface unambiguously determined. Emission from the spolarization (where the E-field is parallel to the surface and normal to the wave vector) is generally less intense than emission from the p-polarization (E-field that is normal to the s-polarization E-field and the wave vector.) The emissivity and temperature may be inferred directly without assuming any specific functional form for the emissivity or resorting to published data tables (which usually do not apply when temperatures reach the WDM regime). We have derived the theory of polarized emission from hot metals, and consider an improved method of temperature determination that takes advantage of polarization measurements, which we call polarization pyrometry. Thus far we have successfully applied the theory to electrically heated metallic filaments, and will apply the theory to beam heated targets when chamber space constraints are removed that will make it feasible to observe the targets at multiple angles. For the case of experiments on NDCX-II, hydrodynamic expansion on a nanosecond timescale that is comparable to the heating time will result in an expanding fluid, with a strong (but finite) density and temperature gradient. Emission will be observed from positions in the foil near the critical density (where the observation photon frequency is equal to the local plasma frequency). By assuming a brightness temperature equal to the local fluid temperature at the critical frequency, a time history of the emission spectrum from an expanding foil can be synthesized from a hydrodynamic simulation of the target. We find that observations from the ultraviolet to the infrared will allow a probing of the target at different depths, and will allow a test of specific equations of state. Improved versions of this theory that integrate the electric field along a ray from the interior of the metal to observation point are being constructed to give a more accurate description of the emitted spectrum.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Study on the High-Pressure Behavior of Goethite up to 32 GPa Using X-Ray Diffraction, Raman, and Electrical Impedance Spectroscopy

Goethite is a major iron-bearing sedimentary mineral on Earth. In this study, we conducted in situ high-pressure x-ray diffraction, Raman, and electrical impedance spectroscopy measurements of goethite using a diamond anvil cell (DAC) at room temperature and high pressures up to 32 GPa. We observed feature changes in both the Raman spectra and electrical resistance at about 5 and 11 GPa. However, the x-ray diffraction patterns show no structural phase transition in the entire pressure range of the study. The derived pressure-volume (P-V) data show a smooth compression curve with no clear evidence of any second-order phase transition. Fitting the volumetric data to the second-order Birch–Murnaghan equation of state yields V 0 = 138.9 ± 0.5 Å 3 and K 0 = 126 ± 5 GPa.

58 GEOSCIENCES↗

Model-independent Exoplanet Transit Spectroscopy

We propose a new data analysis method for obtaining transmission spectra of exoplanet atmospheres and brightness variation across the stellar disk from transit observations. The new method is capable of recovering exoplanet atmosphere absorption spectra and stellar specific intensities without relying on theoretical models of stars and planets. We simultaneously fit both stellar specific intensity and planetary radius directly to transit light curves. This allows stellar models to be removed from the data analysis. Furthermore, we use a data quality weighted filtering technique to achieve an optimal trade-off between spectral resolution and reconstruction fidelity homogenizing the signal-to-noise ratio across the wavelength range. Such an approach is more efficient than conventional data binning onto a low-resolution wavelength grid. We demonstrate that our analysis is capable of reproducing results achieved by using an explicit quadratic limb-darkening equation and that the filtering technique helps eliminate spurious spectral features in regions with strong telluric absorption. The method is applied to the VLT FORS2 observations of the exoplanets GJ 1214 b and WASP-49 b, and our results are in agreement with previous studies. Comparisons between obtained stellar specific intensity and numerical models indicates that the method is capable of accurately reconstructing the specific intensity. The proposed method enables more robust characterization of exoplanetary atmospheres by separating derivation of planetary transmission and stellar specific intensity spectra (that is model-independent) from chemical and physical interpretation.

79 ASTRONOMY AND ASTROPHYSICS↗

Studies of cluster X-ray sources, energy spectra for the Perseus, Virgo, and Coma clusters

Final Uhuru X-ray differential-energy spectra are presented for the Perseus, Virgo, and Coma clusters. Power-law and isothermal bremsstrahlung model spectra with low-energy cutoffs are given, and the energy-dependent Gaunt factor is calculated for the bremsstrahlung. The spectra, which are best fits to the Uhuru data between 2 and 10 keV, are compared with previous observations of these sources in the energy range from 0.1 to 100 keV. The problem of parameter estimation is discussed, error bars with 68% confidence are given for the independently determined slope and cutoff parameters, and the 68% confidence limits are plotted for the fitted spectral functions. The data for Perseus above 20 keV marginally favor the bremsstrahlung fit, those for Virgo between 0.25 and 1.0 keV clearly favor that curve, and those for Coma indicate a low-energy turnover or cutoff. Implications of such a cutoff are briefly discussed.

Kellogg, E.↗

Refine your search to explore more results.