Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Computing, Instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Computationally designed coiled coil ‘bundlemers’ as model colloidal nanoparticles for solution assembly and materials design (Final Report)

As a collaborative team at the University of Delaware and the University of Pennsylvania, Kloxin, Pochan and Saven designed new biomimetic nanomaterials de novo, leveraging a variety of complementary areas of expertise: computational design of biopolymers (Saven at the University of Pennsylvania), and synthesis and characterization (Kloxin and Pochan at the University of Delaware). Overall activities included: sequence-specific peptide synthesis; covalent crosslinking; noncovalent assembly; site-specific functionalization; and nanostructural characterization using electron microscopy and solution-phase (x-ray and neutron) scattering. Using natural and non-natural amino acids, the team created modular, functional peptide building blocks for elaboration of new nanostructured materials. Ultimately, the development of robust peptide-based, building blocks provides tools for researchers to readily produce complex nanomaterial structures in a wide range of applications. The project had three, interconnecting goals in an effort to provide the broader scientific community with a new peptide-based paradigm for materials design and characterization. First, we further developed the coiled-coil bundle-based toolbox (otherwise known as the ‘bundlemer’ toolbox) via computational design with experimental bundle assembly verification. Second, we developed new uses of covalent interactions, in addition to desired physical (noncovalent) interactions, to assemble bundlemers into 1-D polymer chains with targeted chain rigidity, length, and dispersity. Thirds, we used the above designs to experimentally realize (physical or covalent) polymers to target the creation of liquid crystals or to realize interparticle assembly into nanoporous lattices. The close integration of the three groups was instrumental in success of the biomolecular materials design, formation, and understanding for future designs.

36 MATERIALS SCIENCE↗

Design and Construction of Detector and Data Acquisition Elements for Proton Computed Tomography

Proton computed tomography (pCT) offers an alternative to x-ray imaging with potential for three-dimensional imaging, reduced radiation exposure, and in-situ imaging. Northern Illinois University (NIU) is developing a second-generation proton computed tomography system with a goal of demonstrating the feasibility of three-dimensional imaging within clinically realistic imaging times. The second-generation pCT system is comprised of a tracking system, a calorimeter, data acquisition, a computing farm, and software algorithms. The proton beam encounters the upstream tracking detectors, the patient or phantom, the downstream tracking detectors, and a calorimeter. The schematic layout of the PCT system is shown. The data acquisition sends the proton scattering information to an offline computing farm. Major innovations of the second generation pCT project involve an increased data acquisition rate ( MHz range) and development of three-dimensional imaging algorithms. The Fermilab Particle Physics Division and Northern Illinois Center for Accelerator and Detector Development at Northern Illinois University worked together to design and construct the tracking detectors, calorimeter, readout electronics and detector mounting system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a Micromegas TPC for Low Energy Heavy Ions Measurement for Nuclear Fission and Astrophysics Applications

Time Projection Chambers are widely used since many years for tracking and identification of charged particles in high energy physics. We present a new R and D project to investigate the feasibility of a Micromegas TPC for low energy heavy ions detection. Two physics cases are relevant for this project. The first is the study of the nuclear fission of actinides by measuring the fission fragments properties (mass, nuclear charge, kinetic energy) that will be performed at different installations and in particular at the NFS facility to be built in the framework of the SPIRAL2 project in GANIL. The second physics case is the study of heavy ion reactions, like ({alpha},{gamma}), ({alpha},p), ({alpha},n) and all the inverse reactions in the energy range between 1.5 and 3 AMeV using both stable and radioactive beams. These reactions have a key role in p process in nuclear astrophysics to explain the synthesis of heavy proton-rich nuclei. Within the project, a large effort is devoted to Monte-Carlo simulations and a detailed benchmark of different simulation codes on the energy loss and range in gas of heavy ions at low energy has been performed. A new approach for simulating the ion charge state evolution in GEANT4 is also presented. Finally, preliminary results of an experimental test campaign on prototype are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A high performance neutron powder diffractometer at 3 MW Triga Mark-II research reactor in Bangladesh

A high performance neutron diffractometer called Savar Neutron Diffractometer (SAND) was built and installed at radial beam port-2 of TRIGA Mark II research reactor at AERE, Savar, Dhaka, Bangladesh. Structural studies of materials are being done by this technique to characterize materials crystallograpohically and magnetically. The micro-structural information obtainable by neutron scattering method is very essential for determining its technological applications. This technique is unique for understanding the magnetic behavior in magnetic materials. Ceramic, steel, electronic and electric industries can be benefited from this facility for improving their products and fabrication process. This instrument consists of a Popovicimonochromator with a large linear position sensitive detector array. The monochromator consists of nine blades of perfect single crystal of silicon with 6 mm thickness each. The monochromator design was optimized to provide maximum flux on 3 mm diameter cylindrical sample with a relatively flat angular dependence of resolution. Five different wave lengths can be selected by orienting the crystal at various angles. A sapphire filter was used before the primary collimator to minimize the first neutron. The detector assembly is composed of 15 linear position sensitive proportional counters placed at either 1.1 m or 1.6 m from the sample position and enclosed in a air pad supported high density polythene shield. Position sensing is obtained by charge division using 1-wide NIM position encoding modules (PEM). The PEMs communicate with the host computer via USB. The detector when placed at 1.1 m, subtends 30° (2θ) at each step and covers 120° in 4 steps. When the detector is placed at 1.6 m it subtends 20° at each step and covers 120° in 6 steps. The instrument supports both low and high temperature sample environment. The instrument supports both low and high temperature sample environment. The diffractometer is a state-of-the art technology for diffraction study in our country.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Purification of Zirconium Tetrachloride from UNF Cladding

The overarching objective of this project was to design and demonstrate (laboratory scale) a sublimation-based purification protocol to obtain pure zirconium chloride (ZrCl 4 ) from impure feeds derived from the direct chlorination of Zircaloy cladding materials. To achieve this objective the following goals were identified. (1) Design, construct and test an apparatus capable of subliming and purifying ZrCl 4 at room pressure and temperatures between 600 and 700K (sublimation point of ZrCl 4 606 K). (2) Investigate reactions that may be used to chemically alter the makeup of the impure ZrCl 4 feed materials to enhance their removal from ZrCl 4 in the sublimation-purification process. (3) Computationally model the reactions of metal chlorides in the gas phase under sublimation conditions (1 atm, 600 K) to determine if oligomers are formed and, if formed, how they would influence sublimation-based purification strategies. All experimental investigations performed as part of this project used stable (non-radioactive) compounds and materials as surrogates for the impure ZrCl 4 feedstocks that would be derived from the direct chlorination of Zircaloy claddings from spent nuclear fuel rods. No radiologically active materials were used at any time in this project. The impure ZrCl 4 feedstocks used in this study were derived from the direct chlorination of virgin Zircaloy claddings (Zirc-2, -4 and high Nb). The main goals of the project have been achieved during the three year period of this NEUP sponsored project. The impurities of greatest concern in the feedstocks were identified as the chloride salts of the alloying metals originally found in Zircaloy (Fe, Nb) and radiological contaminants (Cs, Sr, and Sb). A series of prototype sublimation apparatuses and heating arrangements were designed, constructed and tested. A general batch-sublimator design was identified and a 1.0 kg batch sublimator/oven system was fabricated from glass. Purification protocols developed on small scale runs were found to scale to 1.0 kg batches without problem. Purification factor ranges (PFs: wt% final / wt% initial ) for the impurity chlorides identified above have been measured: Fe (40 – 500); Nb (10 – 70); Cs (520 – 5000); Sr (250 – 1900); Sb (220 – 2300). Removal of iron is sensitive to the partial pressure of hydrogen (in nitrogen) flowing through the system. Lower PFs are obtained when the hydrogen partial pressure is lower. Lower flows are required to raise the iron PF. Removal of niobium is very sensitive to the endpoint determination of the forerun. When judged properly (color change yellow to white in sublimate) reasonable PFs (500) can be achieved. However, as discussed in the conclusions section, endpoint determination can be difficult and significantly lower PFs may be obtained when the endpoint is not correctly identified. Several methods of obtaining quantitative cesium, strontium and antimony PFs were investigated, the best being ICP-MS. The results reported here reflect very limited access to and ICP-MS instrument during the course of this project. It should be noted that, while significantly reduced amounts of antimony are observed in the product, antimony is also found in the exhaust trap after the condenser. Quantum chemical computational modeling studies of the reactions of metal chlorides in the gas phase provided important information about a chemical transport mechanism that could defeat sublimation-based purification strategies. Many metal chlorides are known to oligomerize in the gas phase to reduce their coordinative unsaturation. Dimerization of ZrCl 4 with iron or niobium chlorides would provide a mechanism by which both metal impurities could be carried over with the product during sublimation of the bulk material. Computational modeling conclusively showed that under sublimation conditions in the gas phase, dimerization reactions are not favored thermodynamically due to a significant entropic penalty for the reaction. Therefore, consistent with experimental observations, sublimation-based purification strategies remain viable. The experimental part of the report concludes with a short discussion of the issues that still remain in developing a technologically relevant Zircaloy recycling strategy. The final section of the report is a summary of the quantum chemical investigation of the reactions of metal chlorides in the gas phase under sublimation conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The autofocusing system of the IMAT neutron camera

In this paper, we present the autofocusing system of the imaging instrument to be used on IMAT, a new neutron-imaging facility under construction at the ISIS (UK) target station 2. We have compared 16 different autofocus algorithms to select the one with the best performance. The algorithms have been evaluated by using both a qualitative analysis and a quantitative one. An overall score has been computed and the “contrast based” algorithm has been selected for the autofocusing system. The adopted setup together with the described autofocusing system makes the camera a user-friendly imaging device allowing the optimization of beam time use.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advances in Machine and Deep Learning for Modeling and Real-time Detection of Multi-Messenger Sources

We live in momentous times. The science community is empowered with an arsenal of cosmic messengers to study the universe in unprecedented detail. Gravitational waves, electromagnetic waves, neutrinos, and cosmic rays cover a wide range of wavelengths and timescales. Combining and processing these datasets that vary in volume, speed, and dimensionality requires new modes of instrument coordination, funding, and international collaboration with a specialized human and technological infrastructure. In tandem with the advent of large-scale scientific facilities, the last decade has experienced an unprecedented transformation in computing and signal-processing algorithms. The combination of graphics processing units, deep learning, and the availability of open source, high-quality datasets has powered the rise of artificial intelligence. This digital revolution now powers a multibillion dollar industry, with far-reaching implications in technology and society. In this chapter, we describe pioneering efforts to adapt artificial intelligence algorithms to address computational grand challenges in multi-messenger astrophysics. We review the rapid evolution of these disruptive algorithms, from the first class of algorithms introduced in early 2017 to the sophisticated algorithms that now incorporate domain expertise in their architectural design and optimization schemes. We discuss the importance of scientific visualization and extreme-scale computing in reducing time-to-insight and obtaining new knowledge from the interplay between models and data.

Artificial Intelligence↗

Advance optical fiber probe for simultaneous measurements of solids holdup and particles velocity using simple calibration methods for gas-solid fluidization systems

We report advanced gas-solid optical fiber probe technique that can measure simultaneously solids velocity, solids concentration related quantity, and their time series fluctuations has been implemented with simple and new calibration methods for both solids holdup and particles velocity measurements in gas-solid spouted bed and gas-solid fluidized bed. The needed signal and data processing programs have been developed in our laboratory. New, simple, and reliable calibration methods and the related experimental setups have been established to convert the solids concentration related signal to solids holdup which is a meaningful hydrodynamic parameter and to determine the effective distance between the two tips of the probe for the solids velocity measurements. The new calibration methods have been employed to cover a wide range of particle sizes which usually used in gas-solid spouted beds and gas-solid fluidized beds. Selected results have demonstrated the appropriateness of the advanced optical fiber in measuring both solids holdup and particles velocity in the experimental setups of the gas-solid spouted and fluidized beds. The measurements have been compared against independent techniques of gamma ray computed tomography (CT) and radioactive particle tracking (RPT).

42 ENGINEERING↗

Multiphysics modeling of printed surface acoustic wave thermometers

Surface acoustic wave (SAW) transducers are a class of sensors and actuators that operate on the fundamental principle of piezoelectricity. Aerosol jet printing and other additive manufacturing techniques have resulted in the low-cost fabrication of low-power and small-footprint SAW devices that are suitable for sensing in high-temperature and radioactive environments. In this work, we developed a series of temperature-dependent finite element models for a SAW transducer consisting of printed silver interdigitated transducers (IDTs) deposited onto piezoelectric lithium niobate. Modeling accuracy was evaluated experimentally from room temperature to 200 °C using an aerosol-jet-printed SAW thermometer. A time-domain study enabled visualization of the wave propagation and successfully guided the denoising of the scattering parameter measurement. Additionally, frequency-domain models using traditional modal analysis or the unique port boundary condition feature in COMSOL Multiphysics accurately predicted the temperature-driven natural frequency drift in the SAW thermometer. The finite element models developed in this study serve to facilitate the computer-aided design of future SAW transducers for applications in harsh environments.

47 OTHER INSTRUMENTATION↗

Rapidly Assessing the Quality of Targeted Proteomics Experiments through Monitoring Stable-Isotope Labeled Standards

Selected reaction monitoring (SRM), also known as multiple reaction monitoring (MRM), is a data acquisition technique used in targeted analysis of molecules, including targeted proteomic studies. It exploits the unique capability of triple-quadrupole (QQQ) mass spectrometers to monitor the predefined precursor and fragment ion pairs of specific molecules of interest throughout a liquid chromatography (LC) elution profile. Compared to shotgun proteomics, targeted proteomics using SRM has high selectivity, high sensitivity, and a wide linear dynamic range,(1-3) which makes it especially useful in the accurate and reproducible quantification of low-abundance proteins in highly complex biological samples. SRM has been widely used in the fields of biomarker discovery,(4-7) analysis of protein post-translational modifications(8) and characterization of biological protein networks.(4,9) In the recent years, multiple technical advances have greatly improved the throughput of SRM analyses, allowing for the quantification of hundreds of peptides in a single analysis.(6,7,10) For example, a single 800-plex SRM assay (e.g., 400 unlabeled and heavy-labeled peptide pairs and 2400 transitions with retention time scheduling) using ultrahigh-performance liquid chromatography (UHPLC) has been developed to quantify proteins in plasma.(11) Advanced labeling techniques utilizing in vitro proteome-assisted MRM for protein absolute quantification (iMPAQT) demonstrated the capability of SRM in genome-wide protein quantification of over 18?000 human proteins.(12) Moreover, the scan speed of QQQ instrumentation has been greatly improved in recent releases of commercial instrumentation. The newly developed TSQ Altis (released in 2017) can scan more than 600 transitions per second, which is 6 times more than a traditional QQQ scan speed of 100 transitions per second. The breadth of measurement enabled by these technological improvements to QQQ mass spectrometry has increased the feasibility and popularity of large scale targeted proteomics studies,(13) a major application of which will be in clinical studies in which up to hundreds of protein candidates need to be quantified in hundreds of clinical specimens.(14) Quantitative accuracy is a primary motivating factor for utilizing a targeted proteomics protocol. The precise and reproducible absolute quantification produced by SRM assays is essential to many clinical and laboratory experiments.(15,16) Because the abundance of an endogenous peptide is calculated from the measurement of the spiked-in reference standard, it is essential to assess the data quality of these references.(17) In early applications of targeted proteomics, when instrument speed greatly limited the number of transitions that could be monitored, much of this quality assessment was done manually. However, recent improvements in instrument performance and experimental design have enabled a dramatic increase in the number of target peptides and associated SRM transitions, which makes manual quality assessment an untenable and laborious task. A variety of computational tools assist in SRM experiment design and data analysis. The first task in creating an SRM experiment is the choice of proteins and representative peptides to monitor. Achieving a reliable protein abundance requires appropriately choosing peptides that have a strong signal and are free from interferences in the biological matrix. Numerous computational tools exist to facilitate assay design by identifying peptides and refining SRM transitions.(18-21) To help share these assays and eliminate time spent designing the same transitions at multiple institutions, community portals have begun to host well-designed and vetted assays.(22-24) Analyzing the experimental data requires significant computational effort to align files across replicates and experimental conditions, pick peaks and produce quantitative values, normalize data and perform statistical tests, etc.(25-27)

Gibbons, Bryson C.↗

ISOTOPIC RATIOS IN TITAN's METHANE: MEASUREMENTS AND MODELING

The existence of methane in Titan's atmosphere ({approx}6% level at the surface) presents a unique enigma, as photochemical models predict that the current inventory will be entirely depleted by photochemistry in a timescale of {approx}20 Myr. In this paper, we examine the clues available from isotopic ratios ({sup 12}C/{sup 13}C and D/H) in Titan's methane as to the past atmosphere history of this species. We first analyze recent infrared spectra of CH{sub 4} collected by the Cassini Composite Infrared Spectrometer, measuring simultaneously for the first time the abundances of all three detected minor isotopologues: {sup 13}CH{sub 4}, {sup 12}CH{sub 3}D, and {sup 13}CH{sub 3}D. From these we compute estimates of {sup 12}C/{sup 13}C = 86.5 {+-} 8.2 and D/H = (1.59 {+-} 0.33) Multiplication-Sign 10{sup -4}, in agreement with recent results from the Huygens GCMS and Cassini INMS instruments. We also use the transition state theory to estimate the fractionation that occurs in carbon and hydrogen during a critical reaction that plays a key role in the chemical depletion of Titan's methane: CH{sub 4} + C{sub 2}H {yields} CH{sub 3} + C{sub 2}H{sub 2}. Using these new measurements and predictions we proceed to model the time evolution of {sup 12}C/{sup 13}C and D/H in Titan's methane under several prototypical replenishment scenarios. In our Model 1 (no resupply of CH{sub 4}), we find that the present-day {sup 12}C/{sup 13}C implies that the CH{sub 4} entered the atmosphere 60-1600 Myr ago if methane is depleted by chemistry and photolysis alone, but much more recently-most likely less than 10 Myr ago-if hydrodynamic escape is also occurring. On the other hand, if methane has been continuously supplied at the replenishment rate then the isotopic ratios provide no constraints, and likewise for the case where atmospheric methane is increasing. We conclude by discussing how these findings may be combined with other evidence to constrain the overall history of the atmospheric methane.

79 ASTRONOMY AND ASTROPHYSICS↗

The Commissioning of CMS Sites: Improving the Site Reliability

The computing system of the CMS experiment works using distributed resources from more than 60 computing centres worldwide. These centres, located in Europe, America and Asia are interconnected by the Worldwide LHC Computing Grid. The operation of the system requires a stable and reliable behaviour of the underlying infrastructure. CMS has established a procedure to extensively test all relevant aspects of a Grid site, such as the ability to efficiently use their network to transfer data, the func tionality of all the site services relevant for CMS and the capability to sustain the various CMS computing workflows at the required scale. This contribution describes in detail the procedure to rate CMS sites depending on their performance, including th e complete automation of the program, the description of monitoring tools, and its impact in improving the overall reliability of the Grid from the point of view of the CMS computing system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Composite gravitational-wave detection of compact binary coalescence

The detection of gravitational waves from compact binaries relies on a computationally burdensome processing of gravitational-wave detector data. The parameter space of compact-binary-coalescence gravitational waves is large and optimal detection strategies often require nearly redundant calculations. Previously, it has been shown that singular value decomposition of search filters removes redundancy. Here we will demonstrate the use of singular value decomposition for a composite detection statistic. This can greatly improve the prospects for a computationally feasible rapid detection scheme across a large compact binary parameter space.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-Core Microcontroller Hardware In the Loop System for Electric Machine Control

Hardware in the Loop (HIL) is a simulation technique used to reduce the software development cycle and test control systems in a non-destructive environment. This work describes a cost effective HIL simulator on a dual core microcontroller in which one core acts as a controller and the other emulates the system under control. The emulator runs one step per Pulse Width Modulation (PWM) period in real time. To handle the computational burden and prioritize execution of simulation and control tasks, an interrupt-based software architecture with task prioritization has been developed. As a demonstration, the HIL has been implemented on a Texas Instruments TMS320F28379D dual core microcontroller, which emulates a Permanent Magnet Synchronous Machine (PMSM) with resolver feedback. Hardware peripherals are developed and tested concurrently with the control system, providing higher confidence in the software. By using the peripherals in the HIL development, the controller exercises either the HIL emulation or a pin compatible PMSM testbench. To quantify performance and validate the processor based emulator, the HIL results are compared to the preexisting testbench for accuracy benchmarking at no-load and under load for a range of operating points.

33 ADVANCED PROPULSION SYSTEMS↗

Design and Characterization of a Sodium Iodide (NaI) Array for Coincidence Measurements

An array of sodium iodide detectors (NaI) was constructed to record time-correlated gamma ray measurements. The NaI Array consists of twelve 2×4×16-inch detectors. When the array is placed close to an inspected object, this arrangement provides high efficiency for gamma ray detection, particularly for high-energy gamma rays. Data are collected in time-tagged, list-mode format, which is suitable for the application of a variety of coincidence analysis methods. Automated energy calibration of each detector is accomplished by utilizing gamma radiation from thoriated welding rods that are embedded in the system. The energy resolution of spectra that are produced by the NaI array is 7.3% at 662 keV. The data are processed to sum gamma-ray energies for simultaneous detections in adjacent detectors, which are dominated by the escape of scattered photons from one detector and subsequent absorption in an adjacent detector. When data are processed in this way, the photopeak efficiency exceeds 20% over the range 400 keV to 10 MeV; the total efficiency, which includes the Compton continuum and single and double escape peaks, exceeds 70% over this energy range. Utilization of time correlations enables isolation of spectral features that are associated with the same decay cascade or fission event. Characterization of the response of the NaI Array to both gamma rays and neutrons with the Gamma Detector Response and Analysis Software (GADRAS) enables accurate computation for virtually any radiation sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray CT Scans - Set 2

A collection of x-ray computed tomography scans of specimens from the Denver Museum of Nature & Science.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

IER-518: Data Analysis for High Multiplication Subcritical Experiments [Slides]

This presentation begins with a discussion of goals & motivation. This lecture then covers: experimental configurations, computational models, experimental measurements and simulations. Finally, this presentation concludes with data analysis & results plus a conclusion.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Refine your search to explore more results.