Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Comparators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Regulated dc-to-dc converter for voltage step-up or step-down with input-output isolation

A closed loop regulated dc-to-dc converter employing an unregulated two winding inductive energy storage converter is provided by using a magnetically coupled multivibrator acting as duty cycle generator to drive the converter. The multivibrator is comprised of two transistor switches and a saturable transformer. The output of the converter is compared with a reference in a comparator which transmits a binary zero until the output exceeds the reference. When the output exceeds the reference, the binary output of the comparator drives transistor switches to turn the multivibrator off. The multivibrator is unbalanced so that a predetermined transistor will always turn on first when the binary feedback signal becomes zero.

Feng, S. Y.↗

Cold-air annular-cascade investigation of aerodynamic performance of cooled turbine vanes. 1: Facility description and base (solid) vane performance

The aerodynamic performance of a solid vane was experimentally determined in a full-annular cascade, where three-dimensional effects could be obtained. This vane was of the same size and profile as the cooled vanes to be subsequently tested. The vanes were tested over a pressure ratio range that corresponded to mean-radius ideal aftermixed critical velocity ratios of 0.71 to 0.89. Overall vane aftermixed efficiencies were obtained over this range of critical velocity ratios and compared with results from a four-vane annular-sector cascade. The variation in vane aftermixed conditions and vane aftermixed efficiency with radius were also obtained and compared with design values. Vane surface static-pressure distributions were measured and compared with theory and with the results obtained in the four-vane cascade.

Goldman, L. J.↗

The application of ERTS-1 data to the land use planning process

Land resource data has been extracted on a percent of cell basis from ERTS imagery, RB-57 color infrared imagery and best available conventional sources for a 10,000 square kilometer test area in eastern Wisconsin. First, the data from the three sources is compared on a spatial basis for a 300 square kilometer portion of the test area. For those land resource variables associated with cover, ERTS derived resource data compared favorably with both the RB-57 and conventional data. Second, the effect of the data source on land use decisions is examined. Three interstate highway corridors are located through the same region based upon data extracted from each of the three sources. A policy of preserving natural environmental systems was used as a basis for the corridors selection in each case. The resulting three corridors compare favorably.

Clapp, J. L.↗

Skylab study of water quality

The author has identified the following significant results. Analysis of S-190A imagery from 1 EREP pass over 3 reservoirs in Kansas establishes a strong linear correlation between the red/green radiance ratio and suspended solids. This result compares quite favorably to ERTS MSS CCT results. The linear fits RMS for Skylab is 6 ppm as compared to 12 ppm for ERTS. All of the ERTS satellite passes yielded fairly linear results with typical RMS values of 12 ppm. However, a few of the individual passes did yield RMS values of 5 or 6 ppm which is comparable to the one Skylab pass analyzed. In view of the cloudy conditions in the Skylab photos, yet good results, the indications are that S-190A may do somewhat better than the ERTS MSS in determining suspended load. More S-190A data is needed to confirm this. As was the case with the ERTS MSS, the Skylab S-190A showed no strong correlation with other water quality parameters. S-190B photos because of their high resolution can provide much first look information regarding relative degrees of turbidity within various parts of large lakes and among smaller bodies of water.

Yarger, H. L.↗

Dual frequency microwave radiometer measurements of soil moisture for bare and vegetated rough surfaces

Controlled ground-based passive microwave radiometric measurements on soil moisture were conducted to determine the effects of terrain surface roughness and vegetation on microwave emission. Theoretical predictions were compared with the experimental results and with some recent airborne radiometric measurements. The relationship of soil moisture to the permittivity for the soil was obtained in the laboratory. A dual frequency radiometer, 1.41356 GHz and 10.69 GHz, took measurements at angles between 0 and 50 degrees from an altitude of about fifty feet. Distinct surface roughnesses were studied. With the roughness undisturbed, oats were later planted and vegetated and bare field measurements were compared. The 1.4 GHz radiometer was less affected than the 10.6 GHz radiometer, which under vegetated conditions was incapable of detecting soil moisture. The bare surface theoretical model was inadequate, although the vegetation model appeared to be valid. Moisture parameters to correlate apparent temperature with soil moisture were compared.

Lee, S. L.↗

Exhaust pressure and density of various pulsed MPD-Arc thruster systems

Exhaust flow in a new 155-cm-i.d. vacuum facility is compared with earlier measurements in a small (15.2-cm-i.d.) duct. Reductions in post-transient impact pressure are about 5:1 in the larger facility. Corresponding reduced electron number densities (about 2 x 10 to the 13th power per cu cm) are noted. A new 125-microsec pulse-forming network power source produced no major differences in impact pressure compared to the crowbarred condenser bank used earlier. Comparing a puff gas feed of the arc chamber with a new 10-msec steady gas feed also shows no major difference in impact pressure for 125-microsec powering.

Michels, C. J.↗

Propagation of plane waves in flow through a variable area duct

Duct geometry is an important factor that influences the transmission of sound in a duct. Nonconstant area produces variations in steady flow quantities through the duct, which can cause reflections of acoustic disturbances and the creation of standing wave patterns, and which can attenuate and disperse propagating waves. To study the problem, a second-order-accurate numerical method has been developed. The method of characteristics is used to solve the acoustic equations with the assumption of quasi-one-dimensional flow in the duct. Numerical results are presented over a broad range of frequencies. Low-frequency results are compared with approximate solutions for compact nozzles and high-frequency calculations are compared with results from the short-wave theory. The numerical results are also compared with an analytical solution of the acoustic equations for exponential horn sections with zero mean flow to further establish the validity of the numerical method.

King, L. S.↗

The 6300 A O/1-D/ airglow and dissociative recombination

Measurements of night-time 6300 A airglow intensities at the Arecibo Observatory have been compared with dissociative recombination calculations based on electron densities derived from simultaneous incoherent backscatter measurements. The agreement indicates that the nightglow can be fully accounted for by dissociative recombination. The comparisons are examined to determine the importance of quenching, heavy ions, ionization above the F-layer peak, and the temperature parameter of the model atmosphere. Comparable fits between the observed and calculated intensities are found for several available model atmospheres. The least-squares fitting process, used to make the comparisons, produces comparable fits over a wide range of combinations of neutral densities and of reaction constants. Yet, the fitting places constraints upon the possible combinations; these constraints indicate that the latest laboratory chemical constants and densities extrapolated to a base altitude are mutually consistent.

Wickwar, V. B.↗

Submicrosecond time transfer between the United States, United Kingdom, and Australia via satellite

During 1972 time transfer experiments were run between the U.S. Naval Observatory and the Royal Greenwich Observatory and, in 1973, between the U.S. Naval Observatory and the Division of National Mapping in Canberra, Australia. In both cases the time transfer agent was the TIMATION 2 satellite, 1969-82B. The satellite ephemerides were computed from data provided by the Defense Mapping Agency TRANET. This net tracked the satellite's Doppler transmissions. The phase of the satellite clock was determined from knowledge of the position of the satellite and of the observer and the computed distance between the two. By monitoring the clock on successive passes the rate of the satellite clock was determined at Washington. By again monitoring the satellite clock at the distant station the satellite clock could be compared to the local clock and this local clock compared to the U.S. Naval Observatory clocks. In 1972 the RMS of observations at Greenwich deviated by approximately 1/4 microsecond from a straight line when compared to the Naval Observatory. In 1973 the observation errors at Canberra were approximately half as great.

Easton, R. L.↗

Motor run-up system

A starting system is described for bringing a large synchronous motor up to speed to prevent large power line disturbances at the moment the motor is connected to the power line. The system includes (1) a digital counter which generates a count determined by the difference in frequency between the power line and a small current generated by the synchronous motor; (2) a latch which stores the count; and (3) a comparator which compares the stored count with a newly generated count to determine whether the synchronous motor is accelerating or decelerating. Signals generated by the counter and comparator control the current to a clutch that couples a starting motor to the large synchronous motor.

Daeges, J. J.↗

Cold-air annular-cascade investigation of aerodynamic performance of core-engine-cooled turbine vanes. 1: Solid-vane performance and facility description

The aerodynamic performance of a solid (uncooled) version of a core engine cooled stator vane was experimentally determined in a full-annular cascade, where three-dimensional effects could be obtained. The solid vane, which serves as a basis for comparison with subsequent cooled tests, was tested over a range of aftermixed critical velocity ratios of 0.57 to 0.90. Overall vane aftermixed efficiencies were obtained over this critical velocity ratio range and compared with results from a two-dimensional cascade. The variation in vane efficiency and aftermixed flow conditions with circumferential and radial position were obtained and compared with design values. Vane surface static-pressure distributions were also measured and compared with theoretical results.

Goldman, L. J.↗

Design and evaluation of thermodynamic vent/screen baffle cryogenic storage system

A comprehensive analytical program was performed to compare an integrated thermodynamic vent/screen baffle orbital cryogenic propellant storage and transfer system with other concepts. The screen systems were found to be 20% to 29% lighter in weight than a propulsively accelerated Tug-scale LH2/LO2 resupply module. The screen systems were compared with small-scale supercritical storage systems for the space shuttle fuel cell reactant and life support system fluid supply and were lighter by up to 556 kg (1225 lb) for the extended 30-day mission. When compared with high-pressure gas storage for the spacelab atmosphere supply, the screen system saved 79% of the inert system weight for the 30-day mission. An experimental program found that heat flux rates up to 9,450 watts/sq m (3,000 Btu/hr-sq ft) degraded the LH2 bubble point performance of eight screens by a maximum of 12.5%. No effects of helium pressurant, screen material, or LH2 superheat were observed.

Cady, E. C.↗

Combustion intensity and distribution relation to noise generation

Experiments with several different flame holder geometries were conducted to investigate the degree to which combustion roughness can be altered by altering the flame intensity and flame distribution in a ducted combustion system. The effect of admitting primary air through a plane-slotted or a slotted-swirl vane flame holder was compared and the combustion roughness and noise was contrasted with that obtained with a closed front-end perforated can. The slotted front-end burners produced much smoother burning and less noise than the closed front-end can. No advantage was apparent with swirl vs nonswirl when approximately the same inlet flow distribution was maintained. Preheated inlet air provided somewhat smoother combustion as compared with ambient temperature air. The combustion roughness with methyl alcohol was briefly compared with that of isooctane; indications are that it burns more smoothly, but more detailed studies are needed to substantiate these indications.

Plett, E. G.↗

Heating of solid targets with laser pulses

Analytical and numerical solutions to the heat-conduction equation are obtained for the heating of absorbing media with pulsed lasers. The spatial and temporal form of the temperature is determined using several different models of the laser irradiance. Both surface and volume generation of heat are discussed. It is found that if the depth of thermal diffusion for the laser-pulse duration is large compared to the optical-attenuation depth, the surface- and volume-generation models give nearly identical results. However, if the thermal-diffusion depth for the laser-pulse duration is comparable to or less than the optical-attenuation depth, the surface-generation model can give significantly different results compared to the volume-generation model. Specific numerical results are given for a tungsten target irradiated by pulses of different temporal durations and the implications of the results are discussed with respect to the heating of metals by picosecond laser pulses.

Bechtel, J. H.↗

Soil, water, and vegetation conditions in south Texas

The author has identified the following significant results. To distinguish dead from live vegetation, spectrophotometrically measured infinite reflectance of dead and live corn (Zea mays L.) leaves were compared over the 0.5 to 2.5 micron waveband. Dead leaf reflectance was reached over the entire 0.5 to 2.5 micron waveband by stacking only two to three leaves. Live leaf reflectance was attained by stacking two leaves for the 0.5 to 0.75 micron waveband (chlorophyll absorption region), eight leaves for the 0.75 to 1.35 micron waveband (near infrared region), and three leaves for the 1.35 to 2.5 micron waveband (water absorption region). LANDSAT-1 MSS digital data for 11 December 1973 overpass were used to estimate the sugar cane acreage in Hidalgo County. The computer aided estimate was 22,100 acres compared with the Texas Crop and Livestock Reporting Service estimate of 20,500 acres for the 1973-'74 crop year. Although there were errors of omission from harvested fields that were identified as bare soil and some citrus and native vegetation that were mistakenly identified as sugar cane, the mapped location of sugar cane fields in the county compared favorably with their location on the thematic map generated by the computer.

Wiegand, C. L.↗

Acoustic and aerodynamic performance of a 1.83-meter (6-ft) diameter 1.25-pressure-ratio fan (QF-8)

A 1.25-pressure-ratio 1.83-meter (6-ft) tip diameter experimental fan stage with characteristics suitable for engine application on STOL aircraft was tested for acoustic and aerodynamic performance. The design incorporated proven features for low noise, including absence of inlet guide vanes, low rotor blade tip speed, low aerodynamic blade loading, and long axial spacing between the rotor and stator blade rows. The fan was operated with five exhaust nozzle areas. The stage noise levels generally increased with a decrease in nozzle area. Separation of the acoustic one-third octave results into broadband and pure-tone components showed the broadband noise to be greater than the corresponding pure-tone components. The sideline perceived noise was highest in the rear quadrants. The acoustic results of QF-8 were compared with those of two similar STOL application fans in the test series. The QF-8 had somewhat higher relative noise levels than those of the other two fans. The aerodynamic results of QF-8 and the other two fans were compared with corresponding results from 50.8-cm (20-in.) diam scale models of these fans and design values. Although the results for the full-scale and scale models of the other two fans were in reasonable agreement for each design, the full-scale fan QF-8 results showed poor performance compared with corresponding model results and design expectations. Facility effects of the full-scale fan QF-8 installation were considered in analyzing this discrepancy.

Woodward, R. P.↗

Study of the application of advanced technologies to laminar flow control systems for subsonic transports. Volume 1: Summary

A study was conducted to evaluate the technical and economic feasibility of applying laminar flow control to the wings and empennage of long-range subsonic transport aircraft compatible with initial operation in 1985. For a design mission range of 10,186 km (5500 n mi), advanced technology laminar-flow-control (LFC) and turbulent-flow (TF) aircraft were developed for both 200 and 400-passenger payloads, and compared on the basis of production costs, direct operating costs, and fuel efficiency. Parametric analyses were conducted to establish the optimum geometry for LFC and TF aircraft, advanced LFC system concepts and arrangements were evaluated, and configuration variations maximizing the effectiveness of LFC were developed. For the final LFC aircraft, analyses were conducted to define maintenance costs and procedures, manufacturing costs and procedures, and operational considerations peculiar to LFC aircraft. Compared to the corresponding advanced technology TF transports, the 200- and 400-passenger LFC aircraft realized reductions in fuel consumption up to 28.2%, reductions in direct operating costs up to 8.4%, and improvements in fuel efficiency, in ssm/lb of fuel, up to 39.4%. Compared to current commercial transports at the design range, the LFC study aircraft demonstrate improvements in fuel efficiency up to 131%. Research and technology requirements requisite to the development of LFC transport aircraft were identified.

Sturgeon, R. F.↗

Models for infrared atmospheric radiation

Line and band models for infrared spectral absorption are discussed. Radiative transmittance and integrated absorptance of Lorentz, Doppler, and voigt line profiles were compared for a range of parameters. It was found that, for the intermediate path lengths, the combined Lorentz-Doppler (Voigt) profile is essential in calculating the atmospheric transmittance. Narrow band model relations for absorptance were used to develop exact formulations for total absorption by four wide band models. Several continuous correlations for the absorption of a wide band model were compared with the numerical solutions of the wide band models. By employing the line-by-line and quasi-random band model formulations, computational procedures were developed for evaluating transmittance and upwelling atmospheric radiance. Homogeneous path transmittances were calculated for selected bands of CO, CO2, and N2O and compared with experimental measurements. The upwelling radiance and signal change in the wave number interval of the CO fundamental band were also calculated.

Tiwari, S. N.↗

Refine your search to explore more results.