Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COMPRESSORS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Development and validation of a radial inflow turbine model for simulation of the SNL S-CO 2 split-flow loop

A one-dimensional model for a radial inflow turbine has been developed for super-critical carbon dioxide (S-CO 2 ) Brayton cycle applications. The model accounts for the main phenomena present in the volute, nozzle, and impeller of a single-stage turbine. These phenomena include internal losses due to friction, blade loading, and angle of incidence and parasitic losses due to windage and blade-housing leakage. The model has been added as a component to the G-PASS plant systems code. The model was developed to support the analysis of S-CO 2 cycles in conjunction with small-scale loop experiments. Such loops operate at less than a MWt thermal input. Their size permits components to be reconfigured in new arrangements relatively easily and economically. However, the small thermal input combined with the properties of carbon dioxide lead to turbomachines with impeller diameters of only one to two inches. At these sizes the dominant phenomena differ from those in larger more typical machines. There is almost no treatment in the literature of turbomachines at these sizes. The present work therefore is aimed at developing turbomachine models that support the task of S-CO 2 cycle analysis using small-scale tests. Model predictions were compared against data from an experiment performed for Sandia National Laboratories in the split-flow Brayton cycle loop currently located at Barber-Nichols Inc. The split-flow loop incorporates two turbo-alternator-compressor (TAC) units each incorporating a radial inflow turbine and a radial flow compressor on a common shaft. The predicted thermodynamic conditions at the outlet of the turbine on the main compressor shaft were compared with measured values at different shaft speeds. Two modifications to the original model were needed to better match the experiment data. First, a representation of the heat loss from the volute downstream of the sensed inlet temperature was added. Second, an empirical multiplicative factor was applied to the Euler head and another to the head loss to bring the predicted outlet pressure into better agreement with the experiment. These changes also brought the overall efficiency of the turbine into agreement with values cited by Barber Nichols for small turbines. More generally, the quality of measurement set data can in the future be improved by additional steps taken in the design and operation of the experimental apparatus. First, a thermocouple mounted at the nozzle inlet would provide a better indication of temperature at this key point. Second, heat losses from the turbine should be measured directly. Allowing the impeller to free wheel at inlet conditions and measuring the temperature drop between inlet and outlet would provide a more accurate measure of heat loss. Finally, the enthalpy change during operation is more accurately obtained by measuring the torque on the stator using strain gauges rather than by measuring pressure and temperature at inlet and outlet to infer thermodynamic states.

42 ENGINEERING↗

Cyber Physical Protection for Natural Gas Compression

The secure transport of natural gas through North American pipelines is vital for both home and industrial purposes. GE in collaboration with Baker Hughes and Idaho National Laboratory, completed a US Department of Energy grant program to develop a new cyber-physical protection system that monitors the large compressor stations used to boost pressure and maintain proper gas flow. Algorithms were developed to detect the presence of a cyber-attack that impacts the compressor station physical processes, locate the critical functions being manipulated, and potentially neutralize the attack allowing continued operations. The technology was successfully demonstrated at an operating compressor facility located in New York state.

03 NATURAL GAS↗

Design and Testing of CO2 Compression Using Supersonic Shockware Technology

Documentation of work performed by Ramgen and subcontractors in pursuit of design and construction of a 10 MW supersonic CO{sub 2} compressor and supporting facility. The compressor will demonstrate application of Ramgen's supersonic compression technology at an industrial scale using CO{sub 2} in a closed-loop. The report includes details of early feasibility studies, CFD validation and comparison to experimental data, static test experimental results, compressor and facility design and analyses, and development of aero tools.

42 ENGINEERING↗

Experimental Comparison of Hydrogen Refueling with Directly Pressurized vs. Cascade Method

This paper presents a comparative analysis of two hydrogen station configurations during the refueling process: the conventional “directly pressurized refueling process” and the innovative “cascade refueling process.” The objective of the cascade process is to refuel vehicles without the need for booster compressors. The experiments were conducted at the Hydrogen Research and Fueling Facility located at California State University, Los Angeles. In the cascade refueling process, the facility buffer tanks were utilized as high-pressure storage, enabling the refueling operation. Three different scenarios were tested: one involving the cascade refueling process and two involving compressor-driven refueling processes. On average, each refueling event delivered 1.6 kg of hydrogen. Although the cascade refueling process using the high-pressure buffer tanks did not achieve the pressure target, it resulted in a notable improvement in the nozzle outlet temperature trend, reducing it by approximately 8 °C. Moreover, the overall hydrogen chiller load for the two directly pressurized refuelings was 66 Wh/kg and 62 Wh/kg, respectively, whereas the cascading process only required 55 Wh/kg. This represents a 20% and 12% reduction in energy consumption compared to the scenarios involving booster compressors during fueling. The observed refueling range of 150–350 bar showed that the cascade process consistently required 12–20% less energy for hydrogen chilling. Additionally, the nozzle outlet temperature demonstrated an approximate 8 °C improvement within this pressure range. These findings indicate that further improvements can be expected in the high-pressure region, specifically above 350 bar. This research suggests the potential for significant improvements in the high-pressure range, emphasizing the viability of the cascade refueling process as a promising alternative to the direct compression approach.

08 HYDROGEN↗

NASA HECC Geometry and Performance Review Part 3: A Numerical and Experimental Investigation of Tip Clearance Effects on the Vaneless Diffuser Configuration

Tip clearance effects in centrifugal compressors have been extensively investigated to understand the losses associated with the flow in the impeller tip clearance gap between the rotating blades and the stationary shroud. In Part 3 of this multipart investigation, experimental data and validated numerical simulations from Parts 1 and 2 were used to analyze the effects of the size of the tip clearance gap on the High Efficiency Centrifugal Compressor performance and aerodynamics. Four tip clearance gaps ranging from 0.012-in to 0.030-in (2.0% to 4.9% of the impeller exit blade height) were considered at both design and off-design operating conditions. The total pressure ratio and efficiency of the stage are found to decay linearly with increasing tip gaps. The sensitivity of the impeller performance to the tip gap was found to vary with the rotational speed of the compressor. Spanwise surveys of flow angle, total pressure, and total temperature collected at the impeller exit at design speed are used to validate numerical simulations at each experimental tip gap condition. Numerical simulations show that increased turbulence kinetic energy near the shroud at larger tip gaps leads to spanwise mixing of high entropy fluid near the impeller trailing edge which decreases the useful work input by the impeller. The data presented have been made available to the public in the HECC Data Archive located at https://storage.googleapis.com/hecc-data/NASA-HECC-Data-Archive.zip.

centrifugal compressor↗

NASA HECC Geometry and Performance Review Part 3: A Numerical and Experimental Investigation of Tip Clearance Effects on the Vaneless Diffuser Configuration

Tip clearance effects in centrifugal compressors have been extensively investigated to understand the losses associated with the flow in the impeller tip clearance gap between the rotating blades and the stationary shroud. In Part 3 of this multipart investigation, experimental data and validated numerical simulations from Parts 1 and 2 were used to analyze the effects of the size of the tip clearance gap on the High Efficiency Centrifugal Compressor performance and aerodynamics. Four tip clearance gaps ranging from 0.012-in to 0.030-in (2.0% to 4.9% of the impeller exit blade height) were considered at both design and off-design operating conditions. The total pressure ratio and efficiency of the stage are found to decay linearly with increasing tip gaps. The sensitivity of the impeller performance to the tip gap was found to vary with the rotational speed of the compressor. Spanwise surveys of flow angle, total pressure, and total temperature collected at the impeller exit at design speed are used to validate numerical simulations at each experimental tip gap condition. Numerical simulations show that increased turbulence kinetic energy near the shroud at larger tip gaps leads to spanwise mixing of high entropy fluid near the impeller trailing edge which decreases the useful work input by the impeller. The data presented have been made available to the public in the HECC Data Archive located at https://storage.googleapis.com/hecc-data/NASA-HECC-Data-Archive.zip.

centrifugal compressor↗

System Modeling of kJ-class Petawatt Lasers at LLNL

Advanced Radiographic Capability (ARC) project at the National Ignition Facility (NIF) is designed to produce energetic, ultrafast x-rays in the range of 70-100 keV for backlighting NIF targets. The chirped pulse amplification (CPA) laser system will deliver kilo-Joule pulses at an adjustable pulse duration from 1 ps to 50 ps. System complexity requires sophisticated simulation and modeling tools for design, performance prediction, and comprehension of experimental results. We provide a brief overview of ARC, present our main modeling tools, and describe important performance predictions. The laser system (Fig. 1) consists of an all-fiber front end, including chirped-fiber Bragg grating (CFBG) stretchers. The beam after the final fiber amplifier is split into two apertures and spatially shaped. The split beam first seeds a regenerative amplifier and is then amplified in a multi-pass Nd:glass amplifier. Next, the preamplified chirped pulse is split in time into four identical replicas and injected into one NIF Quad. At the output of the NIF beamline, each of the eight amplified pulses is compressed in an individual, folded, four-grating compressor. Compressor grating pairs have slightly different groove densities to enable compact folding geometry and eliminate adjacent beam cross-talk. Pulse duration is adjustable with a small, rack-mounted compressor in the front-end. We use non-sequential ray-tracing software, FRED for design and layout of the optical system. Currently, our FRED model includes all of the optical components from the output of the fiber front end to the target center (Fig. 2). CAD designed opto-mechanical components are imported into our FRED model to provide a complete system description. In addition to incoherent ray tracing and scattering analysis, FRED uses Gaussian beam decomposition to model coherent beam propagation. Neglecting nonlinear effects, we can obtain a nearly complete frequency domain description of the ARC beam at different stages in the system. We employ 3D Fourier based propagation codes: MIRO, Virtual Beamline (VBL), and PROP for time-domain pulse analysis. These codes simulate nonlinear effects, calculate near and far field beam profiles, and account for amplifier gain. Verification of correct system set-up is a major difficulty to using these codes. VBL and PROP predictions have been extensively benchmarked to NIF experiments, and the verified descriptions of specific NIF beamlines are used for ARC. MIRO has the added capability of treating bandwidth specific effects of CPA. A sample MIRO model of the NIF beamline is shown in Fig. 3. MIRO models are benchmarked to VBL and PROP in the narrow bandwidth mode. Developing a variety of simulation tools allows us to cross-check predictions of different models and gain confidence in their fidelity. Preliminary experiments, currently in progress, are allowing us to validate and refine our models, and help guide future experimental campaigns.

42 ENGINEERING↗

SOURCE OF MICROBUNCHING AT BNL NSLS SOURCE DEVELOPMENT LABORATORY

We report experimental studies of the origins of electron beam microbunching instability at BNL Source Development Laboratory (SDL). We eliminated laser-induced microbunching by utilizing an ultra-short photocathode laser. The measurements of the resulting electron beam led us to conclude that, at SDL, microbunching arising from shot noise is not amplified to any significant level. Our results demonstrated that the only source of microbunching instability at SDL is the longitudinal modulation of the photocathode laser pulse. Our work shows that assuring a longitudinally smoothed photocathode laser pulse allows mitigating microbunching instability at a typical FEL injector with a moderate microbunching gain. In this paper we investigated the source of microbunching instability at the SDL. To distinguish microbunching induced by shot noise from that arising from the longitudinal modulation of the photocathode laser, we studied the beam created by a very short laser pulse, thus eliminating the possibility of laser-induced microbunching. While the measured energy spectra of compressed beam did reveal severe longitudinal fragmentation, an analysis of the beam dynamics proved this to be due to self-fields acting on a beam with an initially smooth longitudinal profile, and not due to microbunching instability. Such fragmentation only was possible with the very short bunch chosen for these studies, and is absent in routine SDL operations. Our experiment shows that in the absence of the initial laser-induced beam modulation, microbunching instability at the SDL is not observed, and must be well below the levels that would limit the FEL performance. This result agrees with assumption of previous SDL studies that (when present under different machine conditions) microbunching instability at the SDL was laser-induced. Microbunching instability gain at the SDL is moderate. This is mainly because the SDL utilizes a single stage bunch compressor as well as due to the small compression ratio. Since the design of the SDL injector is typical of the majority of FEL injectors, our experiment proves that one possible way to control microbunching instability in such machines (that by design have a moderate microbunching gain) is to maintain a sufficiently smooth longitudinal profile of the photo-cathode laser. We note that the general principles for designing a machine with a moderate microbunching instability gain are presented in [12]. In conclusion, our experiment demonstrates that microbunching instability can be eliminated from a typical FEL injector with single stage bunch compressor (and operating without a laser heater) as long as the photocathode laser is longitudinally smooth. For machines with multi-stage bunch compressors, our results offer an important benchmark to establish a minimal laser heater power for instability-free operation.

43 PARTICLE ACCELERATORS↗

Oxygen generator for medical applications (USIC)

The overall Project objective is to develop a portable, non-cryogenic oxygen generator capable of supplying medical grade oxygen at sufficient flow rates to allow the field application of the Topical Hyperbaric Oxygen Therapy (THOT{reg_sign}) developed by Numotech, Inc. This project was sponsored by the U.S. Department of Energy Global Initiatives for Proliferation Prevention (GIPP) and is managed by collaboration between Sandia National Laboratories (SNL), Numotech, Inc, and LLC SPE 'Spektr-Conversion.' The project had two phases, with the objective of Phase I being to develop, build and test a laboratory prototype of the membrane-pressure swing adsorber (PSA) system producing at 15 L/min of oxygen with a minimum of 98% oxygen purity. Phase II objectives were to further refine and identify the pre-requisites needed for a commercial product and to determine the feasibility of producing 15 L/min of oxygen with a minimum oxygen purity of 99%. In Phase I, Spektr built up the necessary infrastructure to perform experimental work and proceeded to build and demonstrate a membrane-PSA laboratory prototype capable of producing 98% purity oxygen at a flow rate of 5 L/min. Spektr offered a plausible path to scale up the process for 15 L/min. Based on the success and experimental results obtained in Phase I, Spektr performed work in three areas for Phase II: construction of a 15 L/min PSA; investigation of compressor requirements for the front end of the membrane/PSA system; and performing modeling and simulation of assess the feasibility of producing oxygen with a purity greater than 99%. Spektr successfully completed all of the tasks under Phase II. A prototype 15 L/min PSA was constructed and operated. Spektr determined that no 'off the shelf' air compressors met all of the specifications required for the membrane-PSA, so a custom compressor will likely need to be built. Modeling and simulation concluded that production of oxygen with purities greater than 99% was possible using a Membrane-PSA system.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Improving the energy efficiency of a refrigerator-freezer through the use of a novel cabinet/door liner based on polylactide biopolymer

This paper presents the energy savings potential of a newly developed liner applied on the foam insulation used in refrigerator and freezer cabinets, compared with using a more commonly used liner made from high-impact polystyrene. The new polylactic acid polymer liner is made from renewable feedstock such as carbon found in plant sugars. The energy use over the life of refrigerator and freezer is calculated using the Energy-Efficient Refrigerator Analysis program developed by the United States Department of Energy to estimate the energy savings potential of various technology option upgrades (cabinet and refrigeration system) for rulemaking purposes. The simulation results show that energy savings from implementing the Ingeo liner range from 818 to 1395tkWh (7.3–12.5% of total energy use) over a 15-year period. In addition to the energy savings, the slower increase in the thermal conductivity of the insulation could allow the compressor to run fewer hours per year compared with a case in which the foam thermal conductivity increases rapidly. This change could increase the life of the compressor and the refrigerators and freezers. As a result, this study does not attempt to quantify the impact of slower foam aging on the compressor life.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental validation of an organic rankine-vapor compression cooling cycle using low GWP refrigerant R1234ze(E)

There is a significant global opportunity to capture and utilize low grade waste heat to reduce fossil fuel consumption, greenhouse gas emissions, and improve energy efficiency across a wide range of industries. In this work, an advanced type of thermally activated cooling system, an organic Rankine-vapor compression cycle (ORVC) with novel heat integration strategies, was designed and tested at a relevant scale for industrial waste heat recovery (300 kW th cooling capacity). The ORVC linked an organic Rankine power cycle and a vapor compression cooling cycle using a turbine and compressor that shared a single shaft. The ORVC test facility absorbed waste heat from a liquid stream at 91 °C to simulate engine coolant in diesel generator sets, rejected heat to a glycol stream at 30 °C, and generated chilled water at 7 °C. A cooling capacity of 264 kW ± 3.5 kW was experimentally validated with a COP of 0.56 ± 0.01 during steady-state operation at the design temperatures. The thermal efficiency, accounting for pump work, of the Rankine cycle was 7.7% ± 0.22% and the COP of the vapor compression cycle was 5.25 ± 0.09. The centrifugal turbo-compressor operated at 31.5 kRPM ± 0.3 kRPM, with a turbine and compressor isentropic efficiencies of 76.7% ± 0.90% and 84.8% ± 0.54%, respectively, with near-perfect power transmission between these components. The pressure drop in the piping and heat exchangers were significantly larger than expected which had a detrimental impact on the performance of the ORVC. In addition, the condenser on the cooling cycle could not deliver the subcooling as specified from the design point modeling. Furthermore, the results from the sensitivity analysis showed that the higher condenser glycol outlet temperature had the largest impact on performance, which is consistent with other analytical models in the literature. When the ORVC simulations were updated with experimental values for isentropic efficiencies of the turbomachinery, the thermal COP was 0.66 which represents an estimate of the predicted performance if test facility limitations are overcome.

30 DIRECT ENERGY CONVERSION↗

The cold high-pressure approach to hydrogen delivery

In view of the very expensive and wasteful nature of today's approaches to H 2 delivery, in this work we explore the possibility of transporting cold (200 K) high pressure (875 bar) H 2 in thermally insulated trailers and dispensing H 2 directly from the trailer, with the potential to eliminate station compressor, cascade, and refrigerator, leading to major reductions in station complexity, maintenance, electricity consumption, and cost, while improving functionality by enabling essentially unlimited back to back refuels, and improving safety due to reduced H 2 expansion energy at low temperature. Detailed techno-economic analysis shows promise for substantial delivery cost reductions through cold high pressure H 2 dispensed directly from the trailer. Results indicate that: (1) Terminal operations for cold high pressure H 2 delivery are $\$$0.32/kg H 2 more expensive than for 350 bar compressed gas delivery (today's lowest cost H 2 delivery technology) due to higher level of pressurization (to 1000 bar) and chilling needs (to 165 K). (2) Trailer cost drops slightly ($\$$0.73 vs. $\$$0.81/kg H 2 for a 350 bar trailer) due to increased capacity (1035 kg H 2 delivered vs. 700 kg) compensating for increased capital cost ($\$$906,900 for cold high pressure H 2 vs. $\$$634,000 for 350 bar trailer). (3) Cold hydrogen delivery presents major advantages in fueling station cost, reduced from $\$$1.27 to $\$$0.46/kg H 2 due to elimination of major system components: compressor, cascade, and chiller. (4) Total compression cost (terminal + station) drops from $\$$0.92/kg H 2 ($\$$0.32 terminal and $\$$0.60 station) for 350 bar trailers to $\$$0.55/kg H 2 (all at the terminal) for cold high pressure H 2 . (5) Elimination of small-scale station compressors is the main contributor to reduced delivery cost due to their inefficiency, capital expense, and maintenance needs. In summary, total delivery cost reduction vs. 350 bar trailer equals $\$$0.58/kg H 2 (from $\$$2.96 to 2.38/kg H 2 ), equivalent to 24% of the total delivery cost. This large cost advantage will improve the economics of H 2 vehicles facilitating the transition to a future of zero emission transportation.

08 HYDROGEN↗

Improving chiller performance and energy efficiency in hydrogen station operation by tuning the auxiliary cooling

In a hydrogen station that operates with direct fueling through the use of a 700 bar boost compressor, the outlet hydrogen temperature can significantly increase, stressing the chiller system. Here, this paper evaluates improvements that can be made to the auxiliary cooling system integrated with the compressor. Both theoretical modeling and experiments were performed at Cal State LA Hydrogen Research and Fueling Facility. The findings suggest that adjusting the auxiliary closed-loop cooling system from 15 °C to 10 °C reduced the station energy consumption and decreased the demand on the station chiller that needed to provide –20 °C hydrogen at the hose. The overall energy consumption for a single fueling reduced by between 2.86 and 9.43% for the set of experiments conducted. After the temperature of the closed-loop cooling system was reduced by 5 °C, the boost compressor outlet temperature dropped from 46-50 °C–40 °C and consequently at the hose the hydrogen temperature declined by 3 °C. Results were scaled up with a forecast on the number of daily refueling events. With a low number of daily fuelings, the proposed set-up showed a minor influence on the overall station energy consumption. However, the benefits were more pronounced for a connector station with sales at 180 kg/day, where the energy efficiency improved by between 1.4 and 5.5%, and even more so for a higher capacity station at 360 kg/day, where the improvement was between 2.9 and 8%.

08 HYDROGEN↗

Modeling and optimization of steady flow of natural gas and hydrogen mixtures in pipeline networks

Here, we extend the canonical problems of simulation and optimization of steady-state gas flows in pipeline networks with compressors to the transport of mixtures of highly heterogeneous gases injected throughout a network. Our study is motivated by proposed projects to blend hydrogen generated using clean energy into existing natural gas pipeline systems as part of efforts to reduce the reliance of energy systems on fossil fuels. Flow in a pipe is related to endpoint pressures by a basic Weymouth equation model, with an ideal gas equation of state, where the wave speed depends on the hydrogen concentration. At vertices, in addition to mass balance, we also consider mixing of incoming flows of varying hydrogen concentrations. The problems of interest are the heterogeneous gas flow simulation (HGFS), which determines system pressures and flows given fixed boundary conditions and compressor settings, as well as the heterogeneous gas flow optimization (HGFO), which extremizes an objective by determining optimal boundary conditions and compressor settings. We examine conditions for uniqueness of solutions to the HGFS, as well as compare and contrast mixed-integer and continuous nonlinear programming formulations for the HGFO. We develop computational methods to solve both problems, and examine their performance using four test networks of increasing complexity.

08 HYDROGEN↗

Parametric Studies of Heat Pump Water Heater Using Low GWP Refrigerants

A storage heat pump water heater (HPWH) comprises a vapor compression system and a hot water tank. It can lead to more than 70% energy saving, compared with electric resistance heating. HPWH usually uses a wrapped-tank coil as the water heater. The wrapped coil has a strong interaction with the water tank and impose a new challenge for the engineering design and simulation study. Based on the US DOE/ORNL Heat Pump Design Model (HPDM), i.e., a public-domain, component-based thermal system modelling platform, a segment-to-segment wrapped-tank coil model coupled with a one-dimensional stratified water tank model were developed, which facilitates modeling and design HPWHs having various configurations and components. Additionally, the hardware-based design model was used to evaluate refrigerants having lower global warming potentials to replace R-134a, including R-1234yf, R-1234ze, R-290, R-513A and R-450A, when effects of compressor size, refrigerant charge on 24-hour uniform energy factor (UEF) and first-hour rating (FHR) were investigated.In the drop-in replacements, R-1234ze achieved the best UEF, and R-290 resulted in the lowest UEF. When downsizing the compressor to maximize the UEFs, the UEFs of R-134a, R-290, R1234yf, R-450A and R-513A ascended to the range of 4.4 to 4.53, with R-513A having the highest UEF. The R-1234ze ended up having the lowest UEF of 4.27. Refrigerants having larger volumetric vaporization heat led to higher FHRs if using the fixed-size compressor, that R-290 resulted in the highest FHR.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

System and Machine Learning-Guided Materials Design for High-Pressure Hydrogen Compression

Cost-effective and reliable hydrogen compression remains a challenging barrier in the widespread adoption of hydrogen as an energy carrier. The prevailing technology of mechanical compression suffers from several drawbacks, some of which can be addressed by nonmechanical compression strategies (e.g., electrochemical or metal hydride-based thermal compression). Thermally driven metal hydride compression strategies typically rely on multistage metal hydride-based compressors; however, discovering or optimizing low-stability metal hydrides that can pressurize hydrogen upward of 1000 bar is difficult, both with respect to computational predictions and experimental validation. Here, in this study, we (1) demonstrate that simple machine learning-derived design rules can inform the rational design of alloying strategies yielding low-stability hydrides, (2) validate their experimental pressure–composition–temperature (PCT) isotherms up to 875 bar, and (3) utilize a dynamic system-level model of a metal hydride compressor design to evaluate their performance under realistic operating conditions. Importantly, this analysis yields predicted operational efficiencies of both 2-stage (90–875 bar) and 3-stage (20–875 bar) metal hydride compressors to enable further evaluation of this technology and its techno-economic outlook.

alloy optimization↗

Proton Driver Linac for the Frankfurt Neutron Source

The Frankfurt Neutron Source at the Stern-Gerlach-Zentrum (FRANZ) will deliver high neutron fluxes in the energy range of 1 to 500 keV. The Activation Mode provides a high averaged neutron flux created by a cw proton beam of up to 5 mA, while in the Compressor Mode intense neutron pulses of 1 ns length are formed with a repetition rate of up to 250 kHz. The Compressor Mode is well-suited for energy-dependent neutron capture measurements using the Time-of-Flight method in combination with a 4{pi} BaF{sub 2} detector array. The design of the proton driver linac for both operation modes is presented. This includes the volume type ion source, the ExB chopper located in the low energy section, the RFQ-IH combination for beam acceleration and the bunch compressor. Finally, the neutron production at the lithium-7 target and the resulting energy spectrum is described.

43 PARTICLE ACCELERATORS↗

Commissioning of helium refrigeration system at JLab for 12 GeV upgrade

The new 4.5 K refrigerator system added to the Jefferson Lab (JLab) Central Helium Liquefier (CHL) for the 12 GeV upgrade will double its previous capacity. It includes a 4.5 K cold box system and compressor system with associated oil removal and gas management systems. At its maximum capacity condition, this new system supports an additional 238 g/s 30 K 1.16 bar cold compressor return flow, a 15 g/s 4.5 K liquefaction load and a 12.6 kW 35–55 K shield load. Five more design conditions, ranging from liquefaction to refrigeration and a stand-by/reduced load state, were specified for the sizing and selection of its components. The cold box system is comprised of a 300–60 K vertical cold box that incorporates a liquid nitrogen pre-cooler and a 60–4.5 K horizontal cold box housing seven turbines that are configured in four expansion stages including one Joule-Thompson expander. The helium compression system has five compressors to support three pressure levels in the cold box. This paper will briefly review the salient 4.5 K system design features and discuss the recent commissioning results.

42 ENGINEERING↗

Refine your search to explore more results.