Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM PROFILES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Behavior and properties of helium cavities in ductile-phase-toughened tungsten irradiated with He + ions at an elevated temperature

Ductile-phase toughened tungsten (DPT W) composites have demonstrated a great potential for plasma-facing components in fusion power systems. These materials can retain the outstanding thermomechanical properties of W while significantly enhancing the fracture toughness. The DPT W composite in this study consists of W particles (88 wt.%) embedded in a ductile NiFeW (12 wt.%) solution matrix. Irradiation of the composite was performed with 90 keV He + ions to 1.0 × 10 17 He + /cm 2 at 973 K. The He cavities formed in both W and NiFeW phases are examined using convergent-beam scanning transmission electron microscopy (CB-STEM) at an atomic-level resolution. Full-range depth profiles of the He cavity diameters and number densities are analyzed. The results show that the average cavity diameter in NiFeW is ~2.7 times that in W, while the number density is an order of magnitude lower. A quantitative analysis of the He density and pressure in the cavities is also achieved using STEM electron energy loss spectroscopy (STEM-EELS) mapping. The He atoms in the cavities in NiFeW are found to be under-pressurized, while those in similar-sized cavities in W are not detectable. Further, the He energy-loss shift exhibits a linear relationship with the He density in cavities in NiFeW, with the slope comparable to that for martensitic steel.

36 MATERIALS SCIENCE↗

The NanoSIMS-HR: The Next Generation of High Spatial Resolution Dynamic SIMS

The high lateral resolution and sensitivity of the NanoSIMS 50 and 50L series of dynamic SIMS instruments have enabled numerous scientific advances over the past 25 years. Here, in this study, we report on the NanoSIMS-HR, the first major upgrade to the series, and analytical tests in a suite of sample types, including an aluminum sample containing silicon crystals, microalgae, and plant roots colonized with a symbiotic fungus. Significant improvements have been made in the Cs + ion source, high voltage (HV) control, stage reproducibility, and other aspects of the instrument that affect performance. The modified design of the NanoSIMS-HR thermal-ionization Cs + source enables a 5 pA primary ion beam to be focused into a 100 nm spot, a ~2.5-fold increase compared to Cs + sources on previous instruments (~2 pA at 100 nm). The brightness of the new Cs + source enables an ultimate lateral resolution as high as 30 nm and improved detection limits for a given analysis area. Sample stage movement accuracy is higher than 500 nm, enabling many-fold higher throughput automated analyses. With the new HV control, the primary ion beam impact energy can be reduced from 16 to 2 keV, which enables higher depth resolution during depth profiling (a 2-fold improvement), albeit with a 5-fold decrease in lateral resolution. In the NanoSIMS-HR, the secondary ion column and detection system are identical to those used in the previous series, and the isotopic analysis performance is as precise as in previous NanoSIMS instruments.

54 ENVIRONMENTAL SCIENCES↗

Measurements with magnetic field in the National Spherical Torus Experiment using the motional Stark effect with laser induced fluorescence diagnostic

The motional Stark effect with laser-induced fluorescence diagnostic (MSE-LIF) has been installed and tested on the National Spherical Torus Experiment (NSTX) at the Princeton Plasma Physics Lab. The MSE-LIF diagnostic will be capable of measuring radially resolved profiles of magnetic field magnitude or pitch angle in NSTX plasmas. The system includes a diagnostic neutral hydrogen beam and a laser which excites the n = 2 to n = 3 transition. A viewing system has been implemented which will support up to 38 channels from the plasma edge to past the magnetic axis. First measurements of MSE-LIF signals in the presence of small applied magnetic fields in neutral gas are reported.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First measurement of time evolution of electron temperature profiles with Nd:YAG Thomson scattering system on Heliotron J

A Nd:YAG Thomson scattering system has been developed for Heliotron J. The system consists of two 550 mJ 50 Hz lasers, large collection optics, and 25 radial channel (∼1 cm spatial resolution) interference polychromators. This measurement system achieves a S/N ratio of ∼50 for low-density plasma (n{sub e} ∼ 0.5 × 10{sup 19} m{sup −3}). A time evolution of electron temperature profiles was measured with this system for a high-intensity gas-puff (HIGP) fueling neutral-beam-injection plasma. The peripheral temperature of the higher-density phase after HIGP recovers to the low-density pre-HIGP level, suggesting that improving particle transport in the HIGP plasma may be possible.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Developing a bright 17 keV x-ray source for probing high-energy-density states of matter at high spatial resolution

A set of experiments were performed on the National Ignition Facility (NIF) to develop and optimize a bright, 17 keV x-ray backlighter probe using laser-irradiated Nb foils. High-resolution one-dimensional imaging was achieved using a 15 μm wide slit in a Ta substrate to aperture the Nb He{sub α} x-rays onto an open-aperture, time integrated camera. To optimize the x-ray source for imaging applications, the effect of laser pulse shape and spatial profile on the target was investigated. Two laser pulse shapes were used—a “prepulse” shape that included a 3 ns, low-intensity laser foot preceding the high-energy 2 ns square main laser drive, and a pulse without the laser foot. The laser spatial profile was varied by the use of continuous phase plates (CPPs) on a pair of shots compared to beams at best focus, without CPPs. A comprehensive set of common diagnostics allowed for a direct comparison of imaging resolution, total x-ray conversion efficiency, and x-ray spectrum between shots. The use of CPPs was seen to reduce the high-energy tail of the x-ray spectrum, whereas the laser pulse shape had little effect on the high-energy tail. The measured imaging resolution was comparably high for all combinations of laser parameters, but a higher x-ray flux was achieved without phase plates. This increased flux was the result of smaller laser spot sizes, which allowed us to arrange the laser focal spots from multiple beams and produce an x-ray source which was more localized behind the slit aperture. Our experiments are a first demonstration of point-projection geometry imaging at NIF at the energies (>10 keV) necessary for imaging denser, higher-Z targets than have previously been investigated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Silicon implantation and annealing in β -Ga 2 O 3 : Role of ambient, temperature, and time

Optimizing thermal anneals of Si-implanted β-Ga 2 O 3 is critical for low resistance contacts and selective area doping. Here we report the impact of annealing ambient, temperature, and time on the activation of room temperature ion-implanted Si in β-Ga 2 O 3 at concentrations from 5 × 10 18 to 1 × 10 20 cm −3 , demonstrating full activation (>80% activation, mobilities >70 cm 2 /V s) with contact resistances below 0.29 Ω mm. Homoepitaxial β-Ga 2 O 3 films, grown by plasma-assisted molecular beam epitaxy on Fe-doped (010) substrates, were implanted at multiple energies to yield 100 nm box profiles of 5 × 10 18 , 5 × 10 19, and 1 × 10 20 cm −3 . Anneals were performed in an ultra-high vacuum-compatible quartz furnace at 1 bar with well-controlled gas compositions. To maintain β-Ga 2 O 3 stability, p O2 must be greater than 10 −9 bar. Anneals up to p O2 = 1 bar achieve full activation at 5 × 10 18 cm −3, while 5 × 10 19 cm −3 must be annealed with p O2 ≤ 10 −4 bar, and 1 × 10 20 cm −3 requires p O2 < 10 −6 bar. Water vapor prevents activation and must be maintained below 10 −8 bar. Activation is achieved for anneal temperatures as low as 850 °C with mobility increasing with anneal temperatures up to 1050 °C, though Si diffusion has been reported above 950 °C. At 950 °C, activation is maximized between 5 and 20 min with longer times resulting in decreased carrier activation (over-annealing). This over-annealing is significant for concentrations above 5 × 10 19 cm −3 and occurs rapidly at 1 × 10 20 cm −3 . Rutherford backscattering spectrometry (channeling) suggests that damage recovery is seeded from remnant aligned β-Ga 2 O 3 that remains after implantation; this conclusion is also supported by scanning transmission electron microscopy showing retention of the β-phase with inclusions that resemble the γ-phase.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantifying the thermal effect and methyl radical production in nanosecond repetitively pulsed glow discharges applied to a methane-air flame

In this work, we investigated non-equilibrium plasma produced by nanosecond repetitively pulsed glow discharges applied across a lean premixed methane-air flame. The flame is stationary, axisymmetric, and laminar. The discharges are applied on the symmetry axis crossing the reactant gases, flame front, and product gases, allowing phase-locked averaged measurements and comparisons with axisymmetric numerical simulations. The thermal effect and methyl radical production are quantified in the discharge in the reactant gas region. One-dimensional, two-beam, hybrid, femtosecond-picosecond, coherent anti-Stokes Raman scattering is used to acquire spatial and temporal profiles of temperature and oxygen-to-nitrogen concentration ratio. Photo-fragmentation laser-induced fluorescence is used to acquire quantitative two-dimensional profiles of methyl radicals in the discharge providing the first quantitative imaging of methyl produced ahead of a flame by plasma-induced methane dissociation. The spatial profiles of temperature and oxygen-to-nitrogen concentration ratio are in steady state, indicating that individual discharges have an insignificant heating effect. Upper and lower bounds of the produced mole fraction of methyl radicals in the plasma are obtained due to uncertainties in the collisional quenching rates of excited state methylidyne radicals in the plasma. The discharges produce a maximum of 600–1100 ppm of methyl radicals upstream of the flame front within 25 ns. This amount is similar to the predicted methyl mole fraction for the flame without plasma and thus represents a significant chemical perturbation to the reactants upstream of the flame front. The produced methyl follows an exponential decay in the first microsecond after the discharge with a decay constant of 8 µs close to the flame, and 0.8 µs further from the flame. The decay then deviates from the exponential curve and the methyl persists for tens of microseconds. The results suggest that for the tested configuration, the thermal effect of individual discharges through fast gas heating is negligible, while active chemical species are produced in large quantities in the reactant gases, upstream of the flame front.

hybrid fs-ps CARS↗

Anomalous helicity-dependent photocurrent in the topological insulator ( Bi 0.5 Sb 0.5 ) 2 Te 3 on a GaAs substrate [Spin manipulation at the interface of a topological insulator and a non-magnetic semiconductor]

We present that the emerging material, topological insulator, has provided new opportunities for spintronic applications, owing to its strong spin-orbit character. Topological insulator based heterostructures that display spin-charge coupling driven by topology at surfaces have great potential for the realization of novel spintronic devices. Here, we report the observation of anomalous photogalvanic effect in (Bi 0.5 Sb 0.5 ) 2 Te 3 thin films grown on GaAs substrate. We demonstrate that the magnitude, direction, and temperature dependence of the helicity-dependent photocurrent (HDPC) can be modulated by the gate voltage. From spatially resolved photocurrent measurements, we show that the line profile of HDPC in (Bi 0.5 Sb 0.5 ) 2 Te 3 /GaAs is unaffected by the variation of beam size, in contrast to the photocurrent response measured in a (Bi 0.5 Sb 0.5 ) 2 Te 3 /mica structure.

36 MATERIALS SCIENCE↗

Vortex rings in event-by-event relativistic heavy-ion collisions

We present event-by-event simulations for central asymmetric light+heavy and Au +Au collisions to investigate the formation and evolution of vortex-ring structures in the longitudinal flow velocity profile. The production-plane polarization of Λ hyperons, defined with respect to the Λ momentum and the beam, can track the “vortex-ring” feature in the event, a characteristic vortical structure generated by longitudinal flow gradients. We make comprehensive model predictions for the rapidity-dependent vortex-ring observables for different collision system sizes at √s NN = 200 and 72 GeV. Furthermore, our predictions at the latter energy can be explored in the future LHCb fixed-target experiment at the Large Hadron Collider.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Charge-exchange recombination spectroscopy of the plasma ion temperature at the T-10 tokamak

Charge-exchange recombination spectroscopy (CXRS) based on a diagnostic neutral beam has been developed at the T-10 tokamak. The diagnostics allows one to measure the ion temperature profile in the cross section of the plasma column. In T-10 experiments, the measurement technique was adjusted and the elements of the CXRS diagnostics for ITER were tested. The used spectroscopic equipment makes it possible to reliably determine the ion temperature from the Doppler broadening of impurity lines (helium, carbon), as well as of the spectral lines of the working gas. The profiles of the plasma ion temperature in deuterium and helium discharges were measured at different plasma currents and densities, including with the use of active Doppler measurements of lines of different elements. The validity and reliability of ion temperature measurements performed by means of the developed CXRS diagnostics are analyzed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Exact design of complex amplitude holograms for producing arbitrary scalar fields

Typical methods to holographically encode arbitrary wavefronts assume the hologram medium only applies either phase shifts or amplitude attenuation to the wavefront. In many cases, phase cannot be introduced to the wavefront without also affecting the amplitude. Here we show how to encode an arbitrary wavefront into an off-axis transmission hologram that returns the exact desired arbitrary wavefunction in a diffracted beam for phase-only, amplitude-only, or mixed phase and amplitude holograms with any periodic groove profile. We apply this to design thin holograms for electrons in a TEM, but our results are generally applicable to light and X-ray optics. We employ a phase reconstruction from a series of focal plane images to qualitatively show the accuracy of this method to impart the expected amplitude and phase to a specific diffraction order.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Beam distortion effects upon focusing an ultrashort petawatt laser pulse to greater than 10 22 W/cm 2

When an ultrashort laser pulse is tightly focused to a size approaching its central wavelength, the properties of the focused spot diverge from the diffraction-limited case. Here, we report on this change in behavior of a tightly focused petawatt-class laser beam by an $f/1$ off-axis parabolic mirror (OAPM). Considering the effects of residual aberration, the spatial profile of the near-field, and pointing error, we estimate the deviation in peak intensities of the focused spot from the ideal case. Here, we verify that the estimated peak intensity values are within an acceptable error range of the measured values. With the added uncertainties in target alignment, we extend the estimation to infer on-target peak intensities of ≥10 22 W/cm 2 for a target at the focal plane of this $f/1$ OAPM.

47 OTHER INSTRUMENTATION↗

Narrow radio recombination lines from ionization fronts

Model weak D-type ionization fronts are used to show that narrow H I radio recombination lines, such as those observed in the directions of several galactic H II regions, may be formed in the outermost layers of an ionization front bounding an H II region. Four model ionization fronts are computed with different values of magnetic-field strength, ionizing photon energy, and initial conditions. The recombination line strengths given by the models are compared with observed line strengths for the H II region NGC 2024, and the observed line profiles are found to be about twice as broad as the model profiles. Some likely explanations for the discrepancy are considered, particularly a variation in front velocity over the observing beam width (Stark broadening is ruled out).

Hill, J. K.↗

Evidence for inhomogeneous thermal sources of two similar solar spike event of 1978, May 5 and December 4

Two short duration single spike events of 1978 May 5 and December 4 exhibit similar time profiles in the microwave and hard X-ray ranges, indicating emission from compact sources. Microwave spectral observations exhibit inhomogeneities present in the source parameters. The existence of fine time structures in the microwave time profiles at 10.4 GHz from Berne are interpreted as a signature of the dynamics of a disturbance travelling through the souce at the ion-sound speed. Stereoscopic observations with the hard X-ray detector on the solar orbiter, Helios-2, and the Berne microwave antennae do not indicate any time lag or differences in the time profiles during the impulsive phase. This is taken as evidence for the absence of directionality of emission making beam models unlikely for short duration single spike events.

Wiehl, H. J.↗

Mass spectrometry in the stratosphere

A gas expansion system incorporating a mass spectrometer that has been successfully flown in the stratosphere is described. Neutral gas particles are formed into a molecular beam that traverses the ion source of the mass spectrometer without wall interactions. It is noted that vertical profiles of such constituents as H2O, CO2, and O3 have been measured in the altitude range of 20 to 40 km during balloon descents. Isotopes of important gases (N2, O2, Ar) provided in-flight calibration standards. Before each flight the mass spectrometer system is calibrated in the laboratory for many gases of interest, including ozone. Mixing ratios of ozone established from recent flights have accuracies of better than 5 percent. The sensitivity of the system is sufficient to detect as well the heavy isotope of ozone at mass 50. A noticeable enhancement of heavy ozone in the upper stratosphere has been found. The mass spectrometer system is seen as providing a unique opportunity to perform in situ measurements in the stratosphere in combination with isotopic studies.

Mauersberger, K.↗

Evidence for inhomogeneous thermal sources of two similar solar spike events of 1978 May 5 and December 4

Two short duration single spike solar events of 1978 May 5 and December 4 exhibit similar time profiles in the microwave and hard X-ray ranges, indicating emission from compact sources. Microwave spectral observations exhibit inhomogeneities present in the source parameters. The existence of fine time structures in the microwave time profiles at 10.4 GHz from Berne are interpreted as a signature of the dynamics of a disturbance traveling through the source at the ion-sound speed. Stereoscopic observations with the hard X-ray detector on the solar orbiter, Helios-2, and the Berne microwave antenna do not indicate any time lag or differences in the time profiles during the impulsive phase. This is taken as evidence for the absence of directionality of emission making beam models unlikely for short duration single spike events. Previously announced in STAR as N83-13047

Desai, U.↗

Dual-parameter radar rainfall measurement from space - A test result from an aircraft experiment

An aircraft experiment has been conducted with a dual-frequency (X/Ka-bands) radar to test various rainfall retrieval methods from space. The authors test a method to derive raindrop size distribution (DSD) parameters from the combination of a radar reflectivity profile and a path-integrated attenuation derived from surface return, which may be available from most spaceborne radars. The estimated DSD parameters are reasonable in that the values generally fall within the range of commonly measured ones and that shifts in DSD parameters appear to be correlated with changes in storm type. The validity of the estimation result is also demonstrated by a consistency check using the Ka-band reflectivity profile which is independent of the DSD estimation process. Although errors may occur in the cases of nonuniform beam filling, these test results indicate the feasibility of the dual-parameter radar measurement from space in achieving a better accuracy in quantitative rainfall remote measurements.

Kozu, Toshiaki↗

Evaluation of a new commercial Monte Carlo dose calculation algorithm for electron beams

Purpose: In this report the authors present the validation of a Monte Carlo dose calculation algorithm (XiO EMC from Elekta Software) for electron beams. Methods: Calculated and measured dose distributions were compared for homogeneous water phantoms and for a 3D heterogeneous phantom meant to approximate the geometry of a trachea and spine. Comparisons of measurements and calculated data were performed using 2D and 3D gamma index dose comparison metrics. Results: Measured outputs agree with calculated values within estimated uncertainties for standard and extended SSDs for open applicators, and for cutouts, with the exception of the 17 MeV electron beam at extended SSD for cutout sizes smaller than 5 × 5 cm{sup 2}. Good agreement was obtained between calculated and experimental depth dose curves and dose profiles (minimum number of measurements that pass a 2%/2 mm agreement 2D gamma index criteria for any applicator or energy was 97%). Dose calculations in a heterogeneous phantom agree with radiochromic film measurements (>98% of pixels pass a 3 dimensional 3%/2 mm γ-criteria) provided that the steep dose gradient in the depth direction is considered. Conclusions: Clinically acceptable agreement (at the 2%/2 mm level) between the measurements and calculated data for measurements in water are obtained for this dose calculation algorithm. Radiochromic film is a useful tool to evaluate the accuracy of electron MC treatment planning systems in heterogeneous media.

61 RADIATION PROTECTION AND DOSIMETRY↗

Refine your search to explore more results.