Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BACKGROUND RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

An Advanced Machine Learning and Artificial Intelligence System for Demonstrating Radiation Regulatory Compliance in DOE Accelerator Facilities

In this Phase II proposal, Applied Research LLC (ARLLC), Thomas Jefferson National Accelerator Facility (Jefferson Lab), and Old Dominion University (ODU) propose the combination of domain knowledge (beam characteristics, fixed structural shielding, earthen burden (the soil and foliage added to the dome of the experimental halls as additional shielding), etc.), machine learning (ML) and/or artificial intelligence (AI) to correlate a variety of multi-modal onsite signals and the radiation fields seen in accessible areas of the accelerator site and the site boundary. The ML/AI will consider the complex influence of environmental parameters affecting the radon contribution of the measurements, focusing on actual data obtained from Jefferson Lab. In Phase I, the coded beam and location data were fed into a deep learning model to predict doses at several designated locations in Jefferson Lab’s facility. Moreover, a dense radiation map was generated using only a sparse collection of the samples in a facility. In Phase II, we will develop a software prototype containing a radiation prediction algorithm, dense radiation map algorithms, and background noise prediction algorithms, with actual data used to evaluate the prototype. This work will provide a framework for evaluation of radiation measurement results around the site based on learned responses. In addition, the proposed approach allows more granular mapping of radiation levels. Better understanding and communication of these levels is related to the overall approach in keeping doses to personnel ALARA.

43 PARTICLE ACCELERATORS↗

Risk of Positive Sentinel Lymph Node After Neoadjuvant Systemic Therapy in Clinically Node-Negative Breast Cancer: Implications for Postmastectomy Radiation Therapy and Immediate Breast Reconstruction

Background: Residual axillary lymph node involvement after neoadjuvant systemic therapy (NST) is the determining factor for postmastectomy radiation therapy (PMRT). Preoperative identification of patients needing PMRT is essential to enable shared decision-making when choosing the optimal timing of breast reconstruction. We determined the risk of positive sentinel lymph node (SLN) after NST in clinically node-negative (cN0) breast cancer. Methods: All cT1-3N0 patients treated with NST followed by mastectomy and SLNB between 2010 and 2016 were identified from the Netherlands Cancer Registry. Rate of positive SLN for different breast cancer subtypes was determined. Logistic regression analysis was performed to determine correlated clinicopathological variables with positive SLN. Results: In total 788 patients were included, of whom 25.0% (197/788) had positive SLN. cT1-3N0 ER+HER2+, cT1-3N0 ER−HER2+ , and cT1-2N0 triple-negative patients had the lowest rate of positive SLN: 7.2–11.5%, 0–6.3%, and 2.9–6.2%, respectively. cT1-3N0 ER+HER2− and cT3N0 triple-negative patients had the highest rate of positive SLN: 23.8–41.7% and 30.4%, respectively. Multivariable regression analysis showed that cT2 (odds ratio [OR] 1.93; 95% confidence interval [CI] 1.01–3.96), cT3 (OR 2.56; 95% CI 1.30–5.38), grade 3 (OR 0.44; 95% CI 0.21–0.91), and ER+HER2− subtype (OR 3.94; 95% CI 1.77–8.74) were correlated with positive SLN. Conclusions: In cT1-3N0 ER+HER2+, cT1-3N0 ER−HER2+, and cT1-2N0 triple-negative patients treated with NST, immediate reconstruction can be considered an acceptable option due to low risk of positive SLN. In cT1-3N0 ER+HER2− and cT3N0 triple-negative patients treated with NST, risks and benefits of immediate reconstruction should be discussed with patients due to the relatively high risk of positive SLN.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

ForSE: A GAN-based Algorithm for Extending CMB Foreground Models to Subdegree Angular Scales

We present ForSE (Foreground Scale Extender), a novel Python package that aims to overcome the current limitations in the simulation of diffuse Galactic radiation, in the context of cosmic microwave background (CMB) experiments. ForSE exploits the ability of generative adversarial neural networks (GANs) to learn and reproduce complex features present in a set of images, with the goal of simulating realistic and non-Gaussian foreground radiation at subdegree angular scales. This is of great importance in order to estimate the foreground contamination to lensing reconstruction, delensing, and primordial B-modes for future CMB experiments. We applied this algorithm to Galactic thermal dust emission in both total intensity and polarization. Our results show how ForSE is able to generate small-scale features (at 12') having as input the large-scale ones (80'). The injected structures have statistical properties, evaluated by means of the Minkowski functionals, in good agreement with those of the real sky and which show the correct amplitude scaling as a function of the angular dimension. Furthermore, the obtained thermal dust Stokes Q and U full-sky maps as well as the ForSE package are publicly available for download.

79 ASTRONOMY AND ASTROPHYSICS↗

NASA’s Galactic Cosmic Ray Simulator – How we study the effects of space radiation on Earth

Earth’s atmosphere and natural magnetic field do a good job protecting us from space radiation. Space radiation is different from radiation on Earth, which mostly comes from isotopes found in rock and soil or from medical procedures like an Xray. Ionizing space radiation comes from particles ejected from the Sun, or solar particle events, and from supernovae outside our solar system making up a background of galactic cosmic radiation. These particles, representing the elements of the periodic table, have been stripped of their electrons as they are accelerated in interstellar space to almost the speed of light. One of NASA’s biggest challenges is protecting astronauts from these high energy particles of galactic cosmic radiation which can cause cancer and other diseases. To understand the biological damage imparted to living systems and to develop protective countermeasures, NASA has built a galactic cosmic ray simulator on Earth.

Space Exploration Missions↗

Evidence for factors modulating radiation-induced G2-delay: potential application as radioprotectors

Manipulation of checkpoint response to DNA damage can be developed as a means for protecting astronauts from the adverse effects of unexpected, or background exposures to ionizing radiation. To achieve this goal reagents need to be developed that protect cells from radiation injury by prolonging checkpoint response, thus promoting repair. We present evidence for a low molecular weight substance excreted by cells that dramatically increases the duration of the G2-delay. This compound is termed G2-Arrest Modulating Activity (GAMA). A rat cell line (A1-5) generated by transforming rat embryo fibroblasts with a temperature sensitive form of p53 plus H-ras demonstrates a dramatic increase in radiation resistance after exposure to low LET radiation that is not associated with an increase in the efficiency of rejoining of DNA double strand breaks. Radioresistance in this cell line correlates with a dramatic increase in the duration of the G2 arrest that is modulated by a GAMA produced by actively growing cells. The properties of GAMA suggest that it is a low molecular weight heat-stable peptide. Further characterization of this substance and elucidation of its mechanism of action may allow the development of a biological response modifier with potential applications as a radioprotector. GAMA may be useful for protecting astronauts from radiation injury as preliminary evidence suggests that it is able to modulate the response of cells exposed to heavy ion radiation, similar to that encountered in outer space.

NASA Discipline Radiation Health↗

Thermoluminescence and phototransferred thermoluminescence dosimetry on mobile phone protective touchscreen glass

Thermoluminescence and phototransferred thermoluminescence measurements of protective glass from smartphones are described. Samples of Gorilla Glass were examined from nine different manufacturers and 40 different phone models. Additionally, 12 glasses believed to be original equipment manufacturer replacements, as well as three glass samples from U.S. finishers, were also studied. Altogether, 99 different Gorilla Glass samples were examined. The radiation-induced thermoluminescence signal produced glow curve shapes specific to the Gorilla Glass generations and could be used to distinguish between them. A background thermoluminescence (and phototransferred thermoluminescence) signal was found in all unirradiated samples. Its intensity and shape were found to be dependent on the Gorilla Glass generation, phone manufacturer, and phone model. The background signal was demonstrated to be produced by ultraviolet light exposure; the shape of the background signal was able to be reproduced by the combined exposure to a broad-spectrum solar simulator and a 302 nm ultraviolet light source. The background signal intensity was found to vary with the location from which it was taken on the glass. It was also found to be dependent on the depth within the Gorilla Glass due to absorption of the ultraviolet light as it traversed the medium. Removal of the glasses’ surface layers was found to be an inadequate method for removing the background signal. In some samples, the background signal intensity was large enough to significantly contribute to the total thermoluminescence (and phototransferred thermoluminescence) signal; therefore, a matrix deconvolution method was introduced to separate the background signal and radiation-induced signal. This method was found to enable dose reconstruction using the radiation-induced signal alone.

61 RADIATION PROTECTION AND DOSIMETRY↗

MAD using INRAD and Radiography [Slides]

We have previously evaluated Intrinsic Radiation Detection Algorithms from vendors for the Department of Homeland Security. These algorithms have limited spectra capability due to both the relatively low spectral content of the signal due to the use of PVT in the Radiation Portal detectors as well as relatively simple algorithms which are based on energy windowing and other simple algorithms to perform classification of Special Nuclear Material. Current detection algorithms are suceptible to nuissance alarms due to Naturally Occuring Radiation (NORM) and variations in background suppression. In this work, we propose to fuse the intrinsic radiation and radiographic data in conjunction with well-established machine learning algorithms to developed enhanced Threat Object detection capability.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Satellite measurements of earth radiation budget for climate applications

Understanding the global balance between the absorption of solar radiation and the emission of longwave radiation is considered pivotal to understanding the processes which govern the earth's climate. In concert with a large scientific community interested in the earth's radiation budget, NASA has initiated a program to accurately determine the spatial and temporal characteristics of the earth's radiation budget. This program will utilize instrumentation placed on three satellites including the Space Shuttle-launched free flying Earth Radiation Budget Satellite. The program is discussed relative to its scientific background, plans for the Earth Radiation Budget Experiment, and the relationship of this effort to present and future climate research activities.

Curran, R. J.↗

Thermal radiation heat transfer (3rd revised and enlarged edition)

This book first reviews the overall aspects and background information related to thermal radiation heat transfer and incorporates new general information, advances in analytical and computational techniques, and new reference material. Coverage focuses on radiation from opaque surfaces, radiation interchange between various types of surfaces enclosing a vacuum or transparent medium, and radiation including the effects of partially transmitting media, such as combustion gases, soot, or windows. Boundary conditions and multiple layers are discussed with information on radiation in materials with nonunity refractive indices.

Siegel, Robert↗

Evaluating the Feasibility of Data Simulation for Radiation Research: Estimating RBE Values for HZE Radiation

As the drive for deep space exploration intensifies, a comprehensive understanding of the health effects of radiation exposure becomes paramount to the future of human space flight. However, epidemiological data for radiation exposure, particularly to high-energy (HZE) ions, is limited, partially due to the financial and logistical costs of radiation studies. As an alternative, this study aims to assess the viability of data simulation strategies to accurately model potential study parameters prior to utilizing laboratory conditions. This study estimates a relative biological effectiveness (RBE) factor based on the solid tumor data for outbred mice provided by Edmundson et al. 2020. Excess relative risk (ERR) models for HZE-Fe ions and gamma radiation were estimated using Poisson regression with Weibull models to represent the background solid tumor hazard without radiation. RBE values were calculated from the ratio of the heavy ion linear slope to the gamma linear slope. The parameters from these models were then applied to simulate iterations of 300 datasets across HZE-Fe doses of 0.05, 0.2, 0.4, and 0.75 Gy; gamma radiation doses of 0.75, 2, and 3 Gy, as well as an unirradiated control group. Sample size per dose varied from 100-500 mice across simulations (800-4000 mice total per dataset). 1500 datasets were generated total (300 each for sample sizes 800, 1600, 3200, and 4000). For each dataset, ERR per radiation type and RBE for HZE-Fe were calculated. The RBE from the Edmondson data was calculated to be 5.55. The RBEs from the simulated data converged around this value across the increasing sample sizes. For n = 4000, the mean RBE across the 300 datasets was 5.71 (95% CI: 5.47-5.95). These results suggest that RBEs calculated from simulated data are credible. Based on this exploration, data simulation is a viable method of testing radiation studies. It provides a method of testing study assumptions and refining research questions prior to embarking on costly laboratory experiments.

Sneha Mehta↗

Quantum Larmor radiation in a conformally flat universe

We investigate the quantum effect on the Larmor radiation from a moving charge in an expanding universe based on the framework of the scalar quantum electrodynamics. A theoretical formula for the radiation energy is derived at the lowest order of the perturbation theory with respect to the coupling constant of the scalar quantum electrodynamics. We evaluate the radiation energy on the background universe so that the Minkowski spacetime transits to the Milne universe, in which the equation of motion for the mode function of the free complex scalar field can be exactly solved in an analytic way. Then, the result is compared with the WKB approach, in which the equation of motion of the mode function is constructed with the WKB approximation which is valid as long as the Compton wavelength is shorter than the Hubble horizon length. This demonstrates that the quantum effect on the Larmor radiation of the order e{sup 2}({h_bar}/2{pi}) is determined by a nonlocal integration in time depending on the background expansion. We also compare our result with a recent work by Higuchi and Walker [Phys. Rev. D 80, 105019 (2009)], which investigated the quantum correction to the Larmor radiation from a charged particle in a nonrelativistic motion in a homogeneous electric field.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Technical Note: Experimental results from a prototype high-field inline MRI-linac

Purpose: The pursuit of real-time image guided radiotherapy using optimal tissue contrast has seen the development of several hybrid magnetic resonance imaging (MRI)-treatment systems, high field and low field, and inline and perpendicular configurations. As part of a new MRI-linac program, an MRI scanner was integrated with a linear accelerator to enable investigations of a coupled inline MRI-linac system. This work describes results from a prototype experimental system to demonstrate the feasibility of a high field inline MR-linac. Methods: The magnet is a 1.5 T MRI system (Sonata, Siemens Healthcare) was located in a purpose built radiofrequency (RF) cage enabling shielding from and close proximity to a linear accelerator with inline (and future perpendicular) orientation. A portable linear accelerator (Linatron, Varian) was installed together with a multileaf collimator (Millennium, Varian) to provide dynamic field collimation and the whole assembly built onto a stainless-steel rail system. A series of MRI-linac experiments was performed to investigate (1) image quality with beam on measured using a macropodine (kangaroo) ex vivo phantom; (2) the noise as a function of beam state measured using a 6-channel surface coil array; and (3) electron contamination effects measured using Gafchromic film and an electronic portal imaging device (EPID). Results: (1) Image quality was unaffected by the radiation beam with the macropodine phantom image with the beam on being almost identical to the image with the beam off. (2) Noise measured with a surface RF coil produced a 25% elevation of background intensity when the radiation beam was on. (3) Film and EPID measurements demonstrated electron focusing occurring along the centerline of the magnet axis. Conclusions: A proof-of-concept high-field MRI-linac has been built and experimentally characterized. This system has allowed us to establish the efficacy of a high field inline MRI-linac and study a number of the technical challenges and solutions.

60 APPLIED LIFE SCIENCES↗

Characterization of the Cherenkov Photon Background for Low-noise Silicon Detectors in Space

Future space observatories that seek to perform imaging and spectroscopy of faint astronomical sources will require ultra-low-noise detectors that are sensitive over a broad wavelength range. Silicon charge-coupled devices (CCDs), such as EMCCDs, skipper CCDs, multi-amplifier sensing CCDs, and single-electron sensitive read out CCDs have demonstrated the ability to detect and measure single photons from X-ray energies to near the silicon band gap (∼1.1 μm), making them candidate technologies for this application. Here, in this context, we study a relatively unexplored source of low-energy background coming from Cherenkov radiation produced by energetic cosmic rays traversing a silicon detector. We present a model for Cherenkov photon production and absorption that is calibrated to laboratory data, and we use this model to characterize the residual background rate for ultra-low-noise silicon detectors in space. We study how the Cherenkov background rate depends on detector thickness, variations in solar activity, and the contribution of heavy cosmic ray species (Z > 2). We find that for thick silicon detectors, such as those required to achieve high quantum efficiency at long wavelengths, the rate of cosmic-ray-induced Cherenkov photon production is comparable to other detector and astrophysical backgrounds. We apply our Cherenkov background model to simulated spectroscopic observations of extra-solar planets, and we find that thick detectors continue to outperform their thinner counterparts at longer wavelengths despite a larger Cherenkov background rate. Furthermore, we find that minimal masking of cosmic-ray tracks continues to maximize the signal-to-noise ratio of very faint sources despite the existence of extended halos of Cherenkov photons.

Astronomical detectors↗

Vector and tensor radiation from Schwarzschild relativistic circular geodesics.

A technique developed by Regge and Wheeler (1957) is applied in the Schwarzschild background geometry to treat the radiation emitted by a test particle moving at a speed close to the local speed of light in the vicinity of a black hole. An analytic expression is obtained for the gravitational and electromagnetic radiation spectrum of a particle traveling in a highly relativistic orbit around a Schwarzschild blac hole.

Breuer, R. A.↗

RADIATIVE TRANSFER IN A CLUMPY UNIVERSE. IV. NEW SYNTHESIS MODELS OF THE COSMIC UV/X-RAY BACKGROUND

We present improved synthesis models of the evolving spectrum of the UV/X-ray diffuse background, updating and extending our previous results. Five new main components are added to our radiative transfer code CUBA: (1) the sawtooth modulation of the background intensity from resonant line absorption in the Lyman series of cosmic hydrogen and helium; (2) the X-ray emission from the obscured and unobscured quasars that gives origin to the X-ray background; (3) a piecewise parameterization of the distribution in redshift and column density of intergalactic absorbers that fits recent measurements of the mean free path of 1 ryd photons; (4) an accurate treatment of the photoionization structure of absorbers, which enters in the calculation of the helium continuum opacity and recombination emissivity; and (5) the UV emission from star-forming galaxies at all redshifts. We provide tables of the predicted H I and He II photoionization and photoheating rates for use, e.g., in cosmological hydrodynamics simulations of the Ly{alpha} forest and a new metallicity-dependent calibration to the UV luminosity density-star formation rate density relation. A 'minimal cosmic reionization model' is also presented in which the galaxy UV emissivity traces recent determinations of the cosmic history of star formation, the luminosity-weighted escape fraction of hydrogen-ionizing radiation increases rapidly with look-back time, the clumping factor of the high-redshift intergalactic medium evolves following the results of hydrodynamic simulations, and Population III stars and miniquasars make a negligible contribution to the metagalactic flux. The model provides a good fit to the hydrogen-ionization rates inferred from flux decrement and proximity effect measurements, predicts that cosmological H II (He III) regions overlap at redshift 6.7 (2.8), and yields an optical depth to Thomson scattering, {tau}{sub es} = 0.084 that is in agreement with Wilkinson Microwave Anisotropy Probe results. Our new background intensities and spectra are sensitive to a number of poorly determined input parameters and suffer from various degeneracies. Their predictive power should be constantly tested against new observations. We are therefore making our redshift-dependent UV/X emissivities and CUBA outputs freely available for public use at http://www.ucolick.org/{approx}pmadau/CUBA.

79 ASTRONOMY AND ASTROPHYSICS↗

Possible infrared signature of decaying particles

A scenario for massive decaying particles is proposed which accounts for the detection of the submillimeter isotropic radiation component of the IR background (Matsumoto et al., 1988). The peak of the decay photon spectrum in the scenario is at several microns. The observed spectrum of the IR background is compared to that of decay photons with degraded energy. Within the limits to the radiative decays of neutrinos from gamma-ray observations os SN 1987A, it is found that the observed spectrum of decay photons is consistent with the IR background spectrum for decaying particle masses in the range between 5 and 18 keV, lifetimes in the range 2-7 X 10 to the 10th s, and a photon branching range of 0.0004 and 0.0009.

Wang, Boqi↗

Refine your search to explore more results.