Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Automating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Concept, implementation and commissioning of the automation system for the accelerator module test facility AMTF

The European XFEL project launched on June 5, 2007 will require about 103 accelerator modules as a main part of the XFEL linear accelerator. All superconducting components constituting the accelerator module like cavities and magnets have to be tested before the assembly. For the tests of the individual cavities and the complete modules an XFEL Accelerator Module Test Facility (AMTF) has been erected at DESY. The process control system EPICS (Experimental Physics and Industrial Control System) is used to control and operate the cryogenic plant and all its subcomponents. A complementary component of EPICS is the Open Source software suit CSS (Control System Studio). CSS is an integrated engineering, maintenance and operating tool for EPICS. CSS enables local and remote operating and monitoring of the complete system and thus represents the human machine interface. More than 250 PROFIBUS nodes work at the accelerator module test facility. DESY installed an extensive diagnostic and condition monitoring system. With these diagnostic tools it is possible to examine the correct installation and configuration of all PROFIBUS nodes in real time. The condition monitoring system based on FDT/DTM technology shows the state of the PROFIBUS devices at a glance. This information can be used for preventive maintenance which is mandatory for continuous operation of the AMTF facility. The poster will describe all steps form engineering to implementation and commissioning.

43 PARTICLE ACCELERATORS↗

An automated miniature robotic vehicle inspection system

A novel, autonomous reconfigurable robotic inspection system for quantitative NDE mapping is presented. The system consists of a fleet of wireless (802.11g) miniature robotic vehicles, each approximately 175 × 125 × 85 mm with magnetic wheels that enable them to inspect industrial structures such as storage tanks, chimneys and large diameter pipe work. The robots carry one of a number of payloads including a two channel MFL sensor, a 5 MHz dry coupled UT thickness wheel probe and a machine vision camera that images the surface. The system creates an NDE map of the structure overlaying results onto a 3D model in real time. The authors provide an overview of the robot design, data fusion algorithms (positioning and NDE) and visualization software.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Note: Artificial neural networks for the automated analysis of force map data in atomic force microscopy

Force curves recorded with the atomic force microscope on structured samples often show an irregular force versus indentation behavior. An analysis of such curves using standard contact models (e.g., the Sneddon model) would generate inaccurate Young's moduli. A critical inspection of the force curve shape is therefore necessary for estimating the reliability of the generated Young's modulus. We used a trained artificial neural network to automatically recognize curves of “good” and of “bad” quality. This is especially useful for improving the analysis of force maps that consist of a large number of force curves.

42 ENGINEERING↗

Image mosaicing for automated pipe scanning

Remote visual inspection (RVI) is critical for the inspection of the interior condition of pipelines particularly in the nuclear and oil and gas industries. Conventional RVI equipment produces a video which is analysed online by a trained inspector employing expert knowledge. Due to the potentially disorientating nature of the footage, this is a time intensive and difficult activity. In this paper a new probe for such visual inspections is presented. The device employs a catadioptric lens coupled with feature based structure from motion to create a 3D model of the interior surface of a pipeline. Reliance upon the availability of image features is mitigated through orientation and distance estimates from an inertial measurement unit and encoder respectively. Such a model affords a global view of the data thus permitting a greater appreciation of the nature and extent of defects. Furthermore, the technique estimates the 3D position and orientation of the probe thus providing information to direct remedial action. Results are presented for both synthetic and real pipe sections. The former enables the accuracy of the generated model to be assessed while the latter demonstrates the efficacy of the technique in a practice.

42 ENGINEERING↗

Automated setup for magnetic hysteresis characterization based on a voltage controlled current source with 500 kHz full power bandwidth and 10 A peak-to-peak current

This paper describes the design of a system for the characterization of magnetic hysteresis behavior in soft ferrite magnetic cores. The proposed setup can test magnetic materials exciting them with controlled arbitrary magnetic field waveforms, including the capability of providing a DC bias, in a frequency bandwidth up to 500 kHz, with voltages up to 32 V peak-to-peak, and currents up to 10 A peak-to-peak. In order to have an accurate control of the magnetic field waveform, the system is based on a voltage controlled current source. The electronic design is described focusing on closed loop feedback stabilization and passive components choice. The system has real-time hysteretic loop acquisition and visualization. The comparisons between measured hysteresis loops of sample magnetic materials and datasheet available ones are shown. Results showing frequency and thermal behavior of the hysteresis of a test sample prove the system capabilities. Moreover, the B-H loops obtained with a multiple waveforms excitation signal, including DC bias, are reported. The proposal is a low-cost and replicable solution for hysteresis characterization of magnetic materials used in power electronics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Towards an automated and efficient calculation of resonating vibrational states based on state-averaged multiconfigurational approaches

Resonating vibrational states cannot consistently be described by single-reference vibrational self-consistent field methods but request the use of multiconfigurational approaches. Strategies are presented to accelerate vibrational multiconfiguration self-consistent field theory and subsequent multireference configuration interaction calculations in order to allow for routine calculations at this enhanced level of theory. State-averaged vibrational complete active space self-consistent field calculations using mode-specific and state-tailored active spaces were found to be very fast and superior to state-specific calculations or calculations with a uniform active space. Benchmark calculations are presented for trans-diazene and bromoform, which show strong resonances in their vibrational spectra.

74 ATOMIC AND MOLECULAR PHYSICS↗

Low vibration high numerical aperture automated variable temperature Raman microscope

Raman micro-spectroscopy is well suited for studying a variety of properties and has been applied to wide- ranging areas. Combined with tuneable temperature, Raman spectra can offer even more insights into the properties of materials. However, previous designs of variable temperature Raman microscopes have made it extremely challenging to measure samples with low signal levels due to thermal and positional instability as well as low collection efficiencies. Thus, contemporary Raman microscope has found limited applicability to probing the subtle physics involved in phase transitions and hysteresis. This paper describes a new design of a closed-cycle, Raman microscope with full polarization rotation. High collection efficiency, thermal and mechanical stability are ensured by both deliberate optical, cryogenic, and mechanical design. Measurements on two samples, Bi 2 Se 3 and V 2 O 3 , which are known as challenging due to low thermal conductivities, low signal levels and/or hysteretic effects, are measured with previously undemonstrated temperature resolution.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Automated force controller for amplitude modulation atomic force microscopy

Atomic Force Microscopy (AFM) is widely used in physics, chemistry, and biology to analyze the topography of a sample at nanometer resolution. Controlling precisely the force applied by the AFM tip to the sample is a prerequisite for faithful and reproducible imaging. In amplitude modulation (oscillating) mode AFM, the applied force depends on the free and the setpoint amplitudes of the cantilever oscillation. Therefore, for keeping the applied force constant, not only the setpoint amplitude but also the free amplitude must be kept constant. While the AFM user defines the setpoint amplitude, the free amplitude is typically subject to uncontrollable drift, and hence, unfortunately, the real applied force is permanently drifting during an experiment. This is particularly harmful in biological sciences where increased force destroys the soft biological matter. Here, we have developed a strategy and an electronic circuit that analyzes permanently the free amplitude of oscillation and readjusts the excitation to maintain the free amplitude constant. As a consequence, the real applied force is permanently and automatically controlled with picoNewton precision. With this circuit associated to a high-speed AFM, we illustrate the power of the development through imaging over long-duration and at various forces. The development is applicable for all AFMs and will widen the applicability of AFM to a larger range of samples and to a larger range of (non-specialist) users. Furthermore, from controlled force imaging experiments, the interaction strength between biomolecules can be analyzed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

3D camera assisted fully automated calibration of scanning laser Doppler vibrometers

Scanning laser Doppler vibrometers (LDV) are used to measure full-field vibration shapes of products and structures. In most commercially available scanning laser Doppler vibrometer systems the user manually draws a grid of measurement locations on a 2D camera image of the product. The determination of the correct physical measurement locations can be a time consuming and diffcult task. In this paper we present a new methodology for product testing and quality control that integrates 3D imaging techniques with vibration measurements. This procedure allows to test prototypes in a shorter period because physical measurements locations will be located automatically. The proposed methodology uses a 3D time-of-flight camera to measure the location and orientation of the test-object. The 3D image of the time-of-flight camera is then matched with the 3D-CAD model of the object in which measurement locations are pre-defined. A time of flight camera operates strictly in the near infrared spectrum. To improve the signal to noise ratio in the time-of-flight measurement, a time-of-flight camera uses a band filter. As a result of this filter, the laser spot of most laser vibrometers is invisible in the time-of-flight image. Therefore a 2D RGB-camera is used to find the laser-spot of the vibrometer. The laser spot is matched to the 3D image obtained by the time-of-flight camera. Next an automatic calibration procedure is used to aim the laser at the (pre)defined locations. Another benefit from this methodology is that it incorporates automatic mapping between a CAD model and the vibration measurements. This mapping can be used to visualize measurements directly on a 3D CAD model. Secondly the orientation of the CAD model is known with respect to the laser beam. This information can be used to find the direction of the measured vibration relatively to the surface of the object. With this direction, the vibration measurements can be compared more precisely with numerical experiments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of a deep learning based automated data analysis for step-filter x-ray spectrometers in support of high-repetition rate short-pulse laser-driven acceleration experiments

We present a deep learning based framework for real-time analysis of a differential filter based x-ray spectrometer that is common on short-pulse laser experiments. The analysis framework was trained with a large repository of synthetic data to retrieve key experimental metrics, such as slope temperature. With traditional analysis methods, these quantities would have to be extracted from data using a time-intensive and manual analysis. Furthermore, this framework was developed for a specific diagnostic, but may be applicable to a wide variety of diagnostics common to laser experiments and thus will be especially crucial to the development of high-repetition rate (HRR) diagnostics for HRR laser systems that are coming online.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantum Chemistry Common Driver and Databases (QCDB) and Quantum Chemistry Engine (QCEngine): Automation and interoperability among computational chemistry programs

We report that community efforts in the computational molecular sciences (CMS) are evolving toward modular, open, and interoperable interfaces that work with existing community codes to provide more functionality and composability than could be achieved with a single program. The Quantum Chemistry Common Driver and Databases (QCDB) project provides such capability through an application programming interface (API) that facilitates interoperability across multiple quantum chemistry software packages. In tandem with the Molecular Sciences Software Institute and their Quantum Chemistry Archive ecosystem, the unique functionalities of several CMS programs are integrated, including CFOUR, GAMESS, NWChem, OpenMM, Psi4, Qcore, TeraChem, and Turbomole, to provide common computational functions, i.e., energy, gradient, and Hessian computations as well as molecular properties such as atomic charges and vibrational frequency analysis. Both standard users and power users benefit from adopting these APIs as they lower the language barrier of input styles and enable a standard layout of variables and data. These designs allow end-to-end interoperable programming of complex computations and provide best practices options by default.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Robust design of semi-automated clustering models for 4D-STEM datasets

Materials discovery and design require characterizing material structures at the nanometer and sub-nanometer scale. Four-Dimensional Scanning Transmission Electron Microscopy (4D-STEM) resolves the crystal structure of materials, but many 4D-STEM data analysis pipelines are not suited for the identification of anomalous and unexpected structures. This work introduces improvements to the iterative Non-Negative Matrix Factorization (NMF) method by implementing consensus clustering for ensemble learning. We evaluate the performance of models during parameter tuning and find that consensus clustering improves performance in all cases and is able to recover specific grains missed by the best performing model in the ensemble. The methods introduced in this work can be applied broadly to materials characterization datasets to aid in the design of new materials.

Bruefach, Alexandra (ORCID:0000000209323477)↗

ETHOS: An automated framework to generate multi-fidelity constitutive data tables and propagate uncertainties to hydrodynamic simulations

Accurate constitutive data, such as equations of state and plasma transport coefficients, are necessary for reliable hydrodynamic simulations of plasma systems such as fusion targets, planets, and stars. Here, we develop a framework for automatically generating transport-coefficient tables using a parameterized model that incorporates data from both high-fidelity sources (e.g., density functional theory calculations and reference experiments) and lower-fidelity sources (e.g., average-atom and analytic models). The framework incorporates uncertainties from these multi-fidelity sources, generating ensembles of optimally diverse tables that are suitable for uncertainty quantification of hydrodynamic simulations. We illustrate the utility of the framework with magnetohydrodynamic simulations of magnetically launched flyer plates, which are used to measure material properties in pulsed-power experiments. We explore how changes in the uncertainties assigned to the multi-fidelity data sources propagate to changes in simulation outputs and find that our simulations are most sensitive to uncertainties near the melting transition. The presented framework enables computationally efficient uncertainty quantification that readily incorporates new high-fidelity measurements or calculations and identifies plasma regimes where additional data will have high impact.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evaluation of oxygenation in the surface layers of biological tissues based on diffuse optical spectroscopy with automated calibration of measurements

To assess the oxygen saturation (oxygenation) in the surface layers of biological tissues (at a depth of 4 mm), a compact system based on diffuse optical spectroscopy (DOS) with reflective measurement geometry in the wavelength range of 520 – 590 nm is proposed. The experimental DOS device is based on a broadband LED source of probe radiation and a spectrometer using a fibre-optic radiation delivery system. To calculate the oxygenation, an original method is proposed based on measuring the intensity of scattered light at four different locations of the source and receiver on the surface of the object under study (four-measurement method). The developed method allows for the device hardware parameters (optical contact with the tissue, transient characteristics of the radiation delivery system) and does not require any additional calibration measurements. The results of testing the DOS system using the four-measurement method for monitoring the oxygen saturation of tissues during the artificial occlusion of the blood vessels agree with the published data of other research teams. (paper)

60 APPLIED LIFE SCIENCES↗

Rapid and automated design of two-component protein nanomaterials using ProteinMPNN

The design of protein–protein interfaces using physics-based design methods such as Rosetta requires substantial computational resources and manual refinement by expert structural biologists. Deep learning methods promise to simplify protein–protein interface design and enable its application to a wide variety of problems by researchers from various scientific disciplines. Here, we test the ability of a deep learning method for protein sequence design, ProteinMPNN, to design two-component tetrahedral protein nanomaterials and benchmark its performance against Rosetta. ProteinMPNN had a similar success rate to Rosetta, yielding 13 new experimentally confirmed assemblies, but required orders of magnitude less computation and no manual refinement. The interfaces designed by ProteinMPNN were substantially more polar than those designed by Rosetta, which facilitated in vitro assembly of the designed nanomaterials from independently purified components. Crystal structures of several of the assemblies confirmed the accuracy of the design method at high resolution. Our results showcase the potential of deep learning–based methods to unlock the widespread application of designed protein–protein interfaces and self-assembling protein nanomaterials in biotechnology.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Automated Hybrid Variance Reduction on Advanced Architectures in the Shift Monte Carlo Code

Monte Carlo transport methods are the most accurate schemes for solving problems with complex energy and spatial features, but they come with a high computational cost. Although hybrid methods have enabled the use of Monte Carlo transport for a large class of problems, they still require significant computing resources. Modern multicore CPUs with large numbers of compute cores and graphical processing units (GPUs) provide opportunities to optimize the memory and run-time costs of hybrid Monte Carlo methods. This paper documents the development and analysis of three Monte Carlo transport algorithms that support hybrid transport using the consistent adjoint-driven importance sampling (CADIS) and forward-weighted CADIS methods in the Shift Monte Carlo code: history-based transport using static and dynamic threading on multicore CPUs and event-based transport enabling weight window tracking on GPUs. The results are shown for two challenging hybrid problems on the Frontier supercomputer at the Oak Ridge Leadership Computing Facility. The results show that all three methods yield good performance and enable solutions of difficult fixed-source transport problems in less than 2 min on 20 nodes of Frontier. Dynamic threading was observed to give up to 20% better scaling behavior than static threading. Moreover, the AMD Instinct 250X GPU was found to give 9 to 11 times greater throughput per graphics compute die than the best CPU performance. In conclusion, additional opportunities for optimization of hybrid transport on GPUs are discussed.

Denovo↗

Automated X-Ray Tomographic Defect Analysis in High Density Carbon Capsules

High density carbon capsule ablators are of primary interest for National Ignition Facility experiments. Two of the major contributors to hydrodynamic instabilities in these capsules are voids and high-density inclusions, where the quantity and size of these defects can result in lower yields in inertial confinement fusion. To aid in capsule selection, General Atomics developed a LabVIEW analysis routine to quantify these defects based off a large field of view tomographic dataset and provide insight into the quality of the capsule. Furthermore, this analysis determines if there are large voids or inclusions that may affect shot performance and helps rank which capsules should be used.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

AUTOMATED VARIABLE STAR CLASSIFICATION USING THE NORTHERN SKY VARIABILITY SURVEY

We have identified 4659 variable objects in the Northern Sky Variability Survey. We have classified each of these objects into one of the five variable star classes: (1) Algol/{beta} Lyr systems including semidetached, and detached eclipsing binaries, (2) W Ursae Majoris overcontact and ellipsoidal variables, (3) long-period variables such as Cepheid and Mira-type objects, (4) RR Lyr pulsating variables, and (5) short-period variables including {delta} Scuti stars. All the candidates have outside of eclipse magnitudes of {approx}10-13. The primary classification tool is the use of Fourier coefficients combined with period information and light-curve properties to make the initial classification. Brief manual inspection was done on all light curves to remove nonperiodic variables that happened to slip through the process and to quantify any errors in the classification pipeline. We list the coordinates, period, Two Micron All Sky Survey colors, total amplitude variation, and any previous classification of the object. 548 objects previously identified as Algols in our previous paper are not included here.

79 ASTRONOMY AND ASTROPHYSICS↗

Refine your search to explore more results.