Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ABLATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Radiochemical Mix Diagnostic in the Presence of Burn

There is a general interest in radiochemical probes of hydrodamicalmix in burning regions of NIF capsule. Here we provide estimates for the production of 13 N from mixing of 10 B ablator burning hotspot of a capsule. By comparing the 13 N signal with x-ray measurements of the ablator mix into the hotspot it should be possible to estimate the chunkiness of this mix.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Epoxy / Silicone Potting Material Removal for Greater Recovery of Circuit Boards

This report documents an exploratory research project, “Epoxy/Silicone Potting Material Removal for Greater Recovery of Circuit Boards,” that investigated micro abrasion and laser ablation as potential cost effective methods for removal of epoxy and silicone potting material from printed circuit boards (PCBs) to expose components for testing and repair. The ability to cost effectively remove such PCB potting materials will improve PCB repair, remanufacture, and reuse opportunities with potential for sizable reductions in material use, E-waste, and energy. Laser ablation was identified as a method potentially warranting further investigation, in particular for epoxy based potting materials.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Radar Detectability Studies of Slow and Small Zodiacal Dust Cloud Particles. III. The Role of Sodium and the Head Echo Size on the Probability of Detection

We present a path forward on a long-standing issue concerning the flux of small and slow meteoroids, which are believed to be the dominant portion of the incoming meteoric mass flux into the Earth’s atmosphere. Such a flux, which is predicted by dynamical dust models of the Zodiacal Cloud, is not evident in ground-based radar observations. For decades this was attributed to the fact that the radars used for meteor observations lack the sensitivity to detect this population, due to the small amount of ionization produced by slow-velocity meteors. Such a hypothesis has been challenged by the introduction of meteor head echo (HE) observations with High Power and Large Aperture radars, in particular the Arecibo 430 MHz radar. Janches et al. developed a probabilistic approach to estimate the detectability of meteors by these radars and initially showed that, with the current knowledge of ablation and ionization, such particles should dominate the detected rates by one to two orders of magnitude compared to the actual observations. In this paper, we include results in our model from recently published laboratory measurements, which showed that (1) the ablation of Na is less intense covering a wider altitude range; and (2) the ionization probability, β{sub ip}, for Na atoms in the air is up to two orders of magnitude smaller for low speeds than originally believed. By applying these results and using a somewhat smaller size of the HE radar target we offer a solution that reconciles these observations with model predictions.

79 ASTRONOMY AND ASTROPHYSICS↗

Direct Determination of the Ionization Energies of PtC, PtO, and PtO2 with VUVRadiation

Photoionization efficiency curves were measured for gas-phase PtC, PtO, and PtO2 using tunable vacuum ultraviolet (VUV) radiation at the Advanced Light Source. The molecules were prepared by laser ablation of a platinum tube, followed by reaction with CH4 or N2O and supersonic expansion. These measurements providethe first directly measured ionization energy for PtC, IE(PtC) = 9.45 +- 0.05 eV. The direct measurement also gives greatly improved ionization energies for the platinum oxides, IE(PtO) = 10.0 +- 0.1 eV and IE(PtO2) = 11.35 +- 0.05 eV. The ionization energy connects the dissociation energies of the neutral and cation, leading to greatly improved 0 K bond dissociation energies for the neutrals: D0(Pt-C) = 5.95 +- 0.07 eV, D0(Pt-O)= 4.30 +- 0.12 eV, and D0(OPt-O) = 4.41 +- 0.13 eV, as well as enthalpies of formation for the gas-phase molecules Delta H0 f,0(PtC(g)) = 701 +- 7 kJ/mol, Delta H0f,0(PtO(g)) = 396 +- 12 kJ/mol, and Delta H0f,0(PtO2(g)) = 218 +- 11 kJ/mol. Much of the error in previous Knudsen cell measurements of platinum oxide bond dissociation energies is due to the use of thermodynamic second law extrapolations. Third law values calculated using statistical mechanical thermodynamic functions are in much better agreement with values obtained from ionization energies and ion energetics. These experiments demonstrate that laser ablation production with direct VUV ionization measurements is a versatile tool to measure ionization energies and bond dissociation energies for catalytically interesting species such as metal oxides and carbides.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Runoff simulations from the Greenland ice sheet at Kangerlussuaq from 2006-2007 to 2007/08. West Greenland

This study focuses on runoff from a large sector of the Greenland Ice Sheet (GrIS) - the Kangerlussuaq drainage area, West Greenland - for the runoff observation period 2006/07 to 2007/08. SnowModel, a state-of-the-art snow-evolution modeling system, was used to simulate winter accumulation and summer ablation processes, including runoff. Independent in situ end-of-winter snow depth and high-resolution runoff observations were used for validation of simulated accumulation and ablation processes. Runoff was modeled on both daily and hourly time steps, filling a data gap of runoff exiting part of the GrIS. Using hourly meteorological driving data instead of smoothed daily-averaged data produced more realistic meteorological conditions in relation to snow and melt threshold surface processes, and produced 6-17% higher annual cumulative runoff. The simulated runoff series yielded useful insights into the present conditions of inter-seasonal and inter-annual variability of Kangerlussuaq runoff, and provided an acceptable degree of agreement between simulated and observed runoff. The simulated spatial runoff distributions, in some areas of the GrIS terminus, were as high as 2,750 mm w.eq. of runoff for 2006/07, while only 900 mm w.eq was simulated for 2007/08. The simulated total runoff from Kangerlussuaq was 1.9 km{sup 3} for 2006/07 and 1.2 km{sup 3} for 2007/08, indicating a reduction of 35-40% caused by the climate conditions and changes in the GrIS freshwater storage. The reduction in runoff from 2006/07 to 2007/08 occurred simultaneously with the reduction in the overall pattern of satellite-derived GrIS surface melt from 2007 to 2008.

58 GEOSCIENCES↗

On the Ionization Energies of C4H3 Isomers

We have conducted a combined experimental and theoretical study on the formation of distinct isomers of resonantly stabilized free radicals, C4H3, which are important intermediates in the formation of polycyclic aromatic hydrocarbons in combustion flames and possibly in the interstellar medium. Our study utilized laser ablation of graphite in combination with seeding the ablated species in neat methylacetylene gas which also acted as a reagent. Photoionization efficiency (PIE) curves were recorded of the C4H3 isomers at the Advanced Light Source from 8.0 to 10.3 eV. The experimental PIE curve was compared with theoretical ones suggesting the formation of four C4H3 radicals: two acyclic structures i-C4H3 [1] and E/Z-n-C4H3 [2E/2Z]and two cyclic isomers 3 and 4. These molecules are likely formed via an initial addition of ground state carbon atoms to the carbon-carbon triple bond of the methylacetylene molecule followed by isomerization via hydrogen migrations and ring opening and emission of atomic hydrogen from these intermediates.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Poly(propylene)/carbon composite thin films obtained by pulsed electron‐beam deposition

For the first time pulsed electron beam deposition (PED) was used to deposit thin films composed of polymer‐carbon composite material. The targets were polypropylene‐carbon (PP/C) composites, with different carbon fillers: carbon black, nanotubes, or graphene. It was confirmed that coatings with composite structure were obtained – the PED method enables complex structures, including nanotubes, to be ablated whole from the target, transported toward substrate, and incorporated into the polymer matrix. These breakthrough results can contribute significantly to improved understanding of the mechanism of electron beam ablation of polymer and composite materials, and open up new possibilities for the deposition of complex composite thin films for use in, for example, advanced sensor applications.

Jędrzejewski, Roman↗

Ultra-High Fidelity Laser-Induced Air Shock from Energetic Materials

Recent interest in the implementation of the Laser-induced Air Shock from Energetic Materials (LASEM) technique prompted an investigation using ultra-high-speed imaging diagnostics to provide early-time (sub-μs) shock-wave-radius-versus-time data necessary to accurately determine the characteristic laser-induced-shock velocity (y-intercept) for high explosives (HE) of interest. Ultra-high-speed focused-shadowgraphy images were collected from nanosecond-pulsed laser-ablated samples of HE similar to those in the published literature. Shadowgraphy images were collected using interframe times ranging from 50–750 ns, with exposure times of 5 ns. Acquired shock-wave-radius-versus-time data permitted a high-fidelity assessment of the shock wave velocity produced at the characteristic radius of the generated laser-plasma pulse. The resulting data from eight different HE indicated that early-time energy contributions and the resulting laser-induced shock velocity profiles produced from ablation of the HE material were indistinguishable amongst the explosives tested for the majority of the time domain characterized (0–12 μs).

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Laser Microdissection and Atmospheric Pressure Chemical Ionization Mass Spectrometry Coupled for Multimodal Imaging

This paper describes the coupling of ambient laser ablation surface sampling, accomplished using a laser capture microdissection system, with atmospheric pressure chemical ionization mass spectrometry for high spatial resolution multimodal imaging. A commercial laser capture microdissection system was placed in close proximity to a modified ion source of a mass spectrometer designed to allow for sampling of laser ablated material via a transfer tube directly into the ionization region. Rhodamine 6G dye of red sharpie ink in a laser etched pattern as well as cholesterol and phosphatidylcholine in a cerebellum mouse brain thin tissue section were identified and imaged from full scan mass spectra. A minimal spot diameter of 8 m was achieved using the 10X microscope cutting objective with a lateral oversampling pixel resolution of about 3.7 m. Distinguishing between features approximately 13 m apart in a cerebellum mouse brain thin tissue section was demonstrated in a multimodal fashion including co-registered optical and mass spectral chemical images.

atmospheric pressure chemical ionization (APCI)↗

Additive manufacturing of platinum group element (PGE) reference materials with a silica matrix

The microanalytical community has an outstanding need for platinum group element (PGE) reference materials, particularly for trace element analysis by laser ablation inductively coupled plasma mass spectrometry (LA-ICPMS). National Institute of Standards and Technology (NIST) glasses contain Rh, Pd, and Pt, but lack Ru, Os, and Ir. Synthesis of silicate PGE standards has proven difficult due the tendency of PGEs to form metallic nuggets. Additive manufacturing methods were used to produce PGE standards with a silica matrix. Monodispersed submicron PGE-doped Stöber particles were used as feedstock materials for electrophoretic deposition (EPD). Two-cm-sized samples produced by EPD were subsequently densified by thermal processing. The homogeneity of PGEs was tested using LA-ICPMS and concentrations were measured by laser ablation and solution ICPMS. The PGE concentrations ranged from 0.5 to 3 μg/g. The inhomogeneity was at the 3% RSD level for Ru, Rh, Ir, and Os throughout and 5% for Pt and Pd in the interior of the samples. Based on LA-ICPMS analyses, the interiors of the two samples have near identical concentrations in PGEs. The samples fabricated in this study represent the most complete and homogeneous PGE standards produced with a silicate matrix. The ability to produce multiple samples with the same composition provides opportunities for validating methods, monitoring long-term reproducibility, and facilitating interlaboratory comparisons.

36 MATERIALS SCIENCE↗

Microscale Metal Additive Manufacturing by Solid‐State Impact Bonding of Shaped Thin Films

The deposition of device-grade inorganic materials is one key challenge toward the implementation of additive manufacturing (AM) in microfabrication, and to that end, a broad range of physico-chemical principles has been explored for 3D fabrication with micro- and nanoscale resolution. Yet, for metals, a process that achieves material quality rivalling that of established thin-film deposition methods, and at the same time, has the potential to combine high throughput production with a broad palette of processable materials, is still lacking. Here, the kinetic, solid-state bonding of metal thin films for the additive assembly of high-purity, high-density metals with micrometer-scale precision is introduced. Indirect laser ablation accelerates micrometer-thick gold films to hundreds of meters per second without their heating or ablation. Their subsequent impact on the substrate above a critical velocity forms a permanent, metallic bond in the solid state. Stacked layers are of high density (>99%). By defining thin-film layers with established lithographic methods prior to launch, a variable feature size (2–50 µm), arbitrary shape of bonded layers, and parallel transfer of up to 36 independent film units in a single shot, is demonstrated. Thus, the solid-state kinetic bonding principle as a viable and potentially versatile route for micro-scale AM of metals is established.

3D printing↗

Single-Cell Metabolomics with Rapid Determination of Chemical Formulas from Isotopic Fine Structures

Metabolomic measurements can provide functional readouts of cellular states and phenotypes. Here, we present a protocol for single-cell metabolomics that permits direct untargeted detection of a broad number of metabolites under ambient conditions, without the need for sample processing, and with high confidence in the discovery and identification of the molecular formulas for detected metabolites. This protocol describes combining fiber-based laser ablation electrospray ionization (f-LAESI) with a 21 Tesla Fourier transform ion cyclotron resonance mass spectrometer (21T-FTICR-MS) to obtain high confidence molecular formula information about detected metabolites. The f-LAESI source utilizes mid-infrared laser ablation through a sharp optical fiber tip, affording direct ambient analysis of cells without the need for sample processing. Using the 21T-FTICR-MS as a mass analyzer enabled measurement of the isotopic fine structure (IFS) for numerous metabolites simultaneously from single cells, and the IFSs were in turn computationally processed to rapidly determine the corresponding elemental compositions. This metabolomics technique complements other single cell omics measurement methods, helping to resolve complex molecular interactions that take place within cells unattainable from single cell transcriptomic and proteomics methods.

mass spectrometry, FTICR, FTMS, ultrahigh mass res↗

Imaging findings during and after percutaneous cryoablation of hepatic tumors

Objective: Imaging plays a key role in the assessment of patients before, during, and after percutaneous cryoablation of hepatic tumors. Intra-procedural and early post-procedure imaging with CT and MRI is vital to the assessment of technical success including adequacy of ablation zone coverage. Recognition of the normal expected post-procedure findings of hepatic cryoablation such as ice ball formation, hydrodissection, and the normal appearance of the ablation zone is crucial to be able to differentiate from complications including vascular, biliary, or non-target organ injury. Delayed imaging is essential for determination of clinical effectiveness and detection of unexpected findings such as residual unablated tumor and local tumor progression. The purpose of this article is to review the spectrum of expected and unexpected imaging findings that may occur during or after percutaneous cryoablation of hepatic tumors. Conclusion: Differentiating expected from unexpected findings during and after hepatic cryoablation helps radiologists identify residual or recurrent tumor and detect procedure-related complications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Determination of the Nonlethal Margin Inside the Visible 'Ice-Ball' During Percutaneous Cryoablation of Renal Tissue

Objective. The study was designed to determine the distance between the visible 'ice-ball' and the lethal temperature isotherm for normal renal tissue during cryoablation. Methods. The Animal Care Committee approved the study. Nine adult swine were used: three to determine the optimum tissue stain and six to test the hypotheses. They were anesthetized and the left renal artery was catheterized under fluoroscopy. Under MR guidance, the kidney was ablated and (at end of a complete ablation) the nonfrozen renal tissue (surrounding the 'ice-ball') was stained via renal artery catheter. Kidneys were explanted and sent for slide preparation and examination. From each slide, we measured the maximum, minimum, and an in-between distance from the stained to the lethal tissue boundaries (margin). We examined each slide for evidence of 'heat pump' effect. Results. A total of 126 measurements of the margin (visible 'ice-ball'-lethal margin) were made. These measurements were obtained from 29 slides prepared from the 6 test animals. Mean width was 0.75 {+-} 0.44 mm (maximum 1.15 {+-} 0.51 mm). It was found to increase adjacent to large blood vessels. No 'heat pump' effect was noted within the lethal zone. Data are limited to normal swine renal tissue. Conclusions. Considering the effects of the 'heat pump' phenomenon for normal renal tissue, the margin was measured to be 1.15 {+-} 0.51 mm. To approximate the efficacy of the 'gold standard' (partial nephrectomy, {approx}98 %), a minimum margin of 3 mm is recommended (3 Multiplication-Sign SD). Given these assumptions and extrapolating for renal cancer, which reportedly is more cryoresistant with a lethal temperature of -40 Degree-Sign C, the recommended margin is 6 mm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Irreversible Electroporation of a Large Centrally Located Hepatocellular Adenoma in a Woman with a Pregnancy Wish

Irreversible electroporation (IRE) is a novel image-guided ablation technique that is rapidly gaining popularity in the treatment of malignant liver tumors located near large vessels or bile ducts. We describe a 28-year-old female patient with a 5 cm large, centrally located hepatocellular adenoma who wished to get pregnant. Regarding the risk of growth and rupture of the adenoma caused by hormonal changes during pregnancy, treatment of the tumor was advised prior to pregnancy. However, due to its central location, the tumor was considered unsuitable for resection and thermal ablation. Percutaneous CT-guided IRE was performed without complications and led to rapid and impressive tumor shrinkage. Subsequent pregnancy and delivery went uncomplicated. This case report suggests that the indication for IRE may extend to the treatment of benign liver tumors that cannot be treated safely otherwise.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hemorrhagic Complications of Percutaneous Cryoablation for Renal Tumors: Results from a 7-year Prospective Study

PurposeCryoablation of renal tumors is assumed to have a higher risk of hemorrhagic complications compared to other ablative modalities. Our purpose was to establish the exact risk and to identify hemorrhagic risk factors.Materials and MethodsThis IRB approved, 7-year prospective study included 261 renal cryoablations. Procedures were under conscious sedation and CT guidance. Pre- and postablation CT was obtained, and hemorrhagic complications were CTCAE tabulated. Age, gender, tumor size, histology, and probes number were tested based on averages or proportions using their exact permutation distribution. “High-risk” subgroups (those exceeding the thresholds of all variables) were tested for each variable alone, and for all combinations of variable threshold values. We compared the subgroup with the best PPV using one variable, with the subgroup with the best PPV using all variables (McNemmar test).ResultsThe hemorrhagic complication rate was 3.5 %. Four patients required transfusions, two required emergent angiograms, one required both a transfusion and angiogram, and two required bladder irrigation for outlet obstruction. Perirenal space hemorrhage was more clinically significant than elsewhere. Univariate risks were tumor size >2 cm, number of probes >2, and malignant histology (P = 0.005, 0.002, and 0.033, respectively). Multivariate analysis showed that patients >55 years with malignant tumors >2 cm requiring 2 or more probes yielded the highest PPV (7.5 %).ConclusionsAlthough older patients (>55 years old) with larger (>2 cm), malignant tumors have an increased risk of hemorrhagic complications, the low PPV does not support the routine use of embolization. Percutaneous cryoablation has a 3.5 % risk of significant hemorrhage, similar to that reported for other types of renal ablative modalities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Role of Interventional Oncology in the Management of Lung Cancer

Interventional radiological procedures for diagnosis and treatment of lung cancer have become increasingly important. Imaging-guided percutaneous biopsy has become the modality of choice for diagnosing lung cancer, and in the era of target therapies, it is an useful tool to define earlier patient-specific tumor phenotypes. In functionally inoperable patients, especially the ablative procedures are potentially curative alternatives to surgery. In addition to thermally ablative treatment, selective chemoembolization by a vascular access allows localized therapy. These treatments are considered for patients in a reduced general condition which does not allow systemic chemotherapy. The present article reviews the role of interventional oncology in the management of primary lung cancer, focusing on the state of the art for each procedure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Irreversible Electroporation for Unresectable Hepatocellular Carcinoma: Initial Experience

Purpose: To evaluate the efficacy and safety of irreversible electroporation (IRE) in the treatment of unresectable hepatocellular carcinoma (HCC). Materials and Methods: A retrospective study was conducted from September 2014 to June 2017. A total of 21 HCCs in 21 patients with cirrhosis were treated with IRE. There were eight subcapsular or exophytic, ten perivascular and three peribiliary tumors. The median tumor size was 26 mm (range 14–40 mm). The technical success of the procedure was recorded. Median follow-up, median time to local recurrence, median local tumor progression-free survival (PFS) and complications were recorded. Results: Technical success was achieved in all the patients. The median follow-up was 10 months (range 2–30 months). The median time to local recurrence and local tumor PFS were 4 months (range 3–4 months) and 7 months (range 3–30 months), respectively. The tumor-related factor that was significantly associated with local PFS was the size. Maximum tumor diameter < 25 mm was significantly associated with local tumor PFS (p = 0.045). Other parameters including tumor location, segmental portal vein thrombosis, baseline alpha-fetoprotein level and underlying etiology did not affect local tumor PFS. Complications were noted in nine patients and were classified as grades 1 and 2. No procedure-related mortality was encountered. Conclusion: IRE is an effective treatment for ablation of small HCCs. Larger prospective studies with strict selection criteria will establish the safety and efficacy of IRE in the treatment of unresectable HCC in patients who cannot undergo thermal ablation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Refine your search to explore more results.