Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “2015”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Technical assessment of compressed hydrogen storage tank systems for automotive applications.

The performance and cost of compressed hydrogen storage tank systems has been assessed and compared to the U.S. Department of Energy (DOE) 2010, 2015, and ultimate targets for automotive applications. The on-board performance and high-volume manufacturing cost were determined for compressed hydrogen tanks with design pressures of 350 bar ({approx}5000 psi) and 700 bar ({approx}10,000 psi) capable of storing 5.6 kg of usable hydrogen. The off-board performance and cost of delivering compressed hydrogen was determined for hydrogen produced by central steam methane reforming (SMR). The main conclusions of the assessment are that the 350-bar compressed storage system has the potential to meet the 2010 and 2015 targets for system gravimetric capacity but will not likely meet any of the system targets for volumetric capacity or cost, given our base case assumptions. The 700-bar compressed storage system has the potential to meet only the 2010 target for system gravimetric capacity and is not likely to meet any of the system targets for volumetric capacity or cost, despite the fact that its volumetric capacity is much higher than that of the 350-bar system. Both the 350-bar and 700-bar systems come close to meeting the Well-to-Tank (WTT) efficiency target, but fall short by about 5%.

03 NATURAL GAS↗

A novel sector mass spectrograph design for high-order coded aperture Mass Spectrometry with stigmatic aberration correction

Previous works experimentally demonstrated that the application of spatially-coded apertures to simple sector mass spectrographs can result in increased signal intensity while maintaining spectral resolution comparable to that of a conventional slit aperture.[Chen, E.X., et al.: J Am Soc Mass Spectr. 26, 1633 (2015)][Russell, Z.E., et al.: J Am Soc Mass Spectr. 26, 248 (2015)] This spatial coding technique was later applied to a double-focusing Mattauch-Herzog mass spectrograph, and shown to be generally compatible with the architecture.[Russell, Z.E., et al.: J Am Soc Mass Spectr. 27, 1 (2016)] However, the achieved signal gain was limited by the spatial size of the electric sector gap. In this work, we introduce a modified version of the Mattauch-Herzog mass spectrograph with a wide-gap electric sector that is enabled by a novel, segmented-electrode approach, and show via simulation that this modified architecture alone (without aperture coding) achieves a 1.8x improvement in mass resolving power compared to a conventional Mattauch-Herzog spectrograph of equivalent size. Further, simulation of an aperture-coded version of the instrument supports a predicted signal strength increase of 50x with minimal loss of aperture clarity on the sensor due to the increased open area of the high-order coded aperture which can be passed.

47 OTHER INSTRUMENTATION↗

Results of the 2013-2015 Association of Residents in Radiation Oncology Survey of Chief Residents in the United States

Purpose: The purpose of this project was to survey radiation oncology chief residents to define their residency experience and readiness for independent practice. Methods and Materials: During the academic years 2013 to 2014 and 2014 to 2015, the Association of Residents in Radiation Oncology (ARRO) conducted an electronic survey of post-graduate year-5 radiation oncology residents in the United States during the final 3 months of training. Descriptive statistics are reported. Results: Sixty-six chief residents completed the survey in 2013 to 2014 (53% response rate), and 69 completed the survey in 2014 to 2015 (64% response rate). Forty to 85% percent of residents reported inadequate exposure to high-dose rate and low-dose rate brachytherapy. Nearly all residents in both years (>90%) reported adequate clinical experience for the following disease sites: breast, central nervous system, gastrointestinal, genitourinary, head and neck, and lung. However, as few as 56% reported adequate experience in lymphoma or pediatric malignancies. More than 90% of residents had participated in retrospective research projects, with 20% conducting resident-led prospective clinical trials and 50% conducting basic science or translational projects. Most chief residents reported working 60 or fewer hours per week in the clinical/hospital setting and performing fewer than 15 hours per week tasks that were considered to have little or no educational value. There was more than 80% compliance with Accreditation Council for Graduate Medical Education (ACGME) work hour limits. Fifty-five percent of graduating residents intended to join an established private practice group, compared to 25% who headed for academia. Residents perceive the job market to be more competitive than previous years. Conclusions: This first update of the ARRO chief resident survey since the 2007 to 2008 academic year documents US radiation oncology residents' experiences and conditions over a 2-year period. This analysis may serve as a valuable tool for those seeking to improve training of the next generation of oncology leaders.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Histologic Subtype in Core Lung Biopsies of Early-Stage Lung Adenocarcinoma is a Prognostic Factor for Treatment Response and Failure Patterns After Stereotactic Body Radiation Therapy

Purpose: Stereotactic body radiation therapy (SBRT) has emerged as an effective treatment for early-stage lung cancer. The histologic subtype of surgically resected lung adenocarcinoma is recognized as a prognostic factor, with the presence of solid or micropapillary patterns predicting poor outcomes. We describe the outcomes after SBRT for early-stage lung adenocarcinoma stratified by histologic subtype. Methods and Materials: We identified 119 consecutive patients (124 lesions) with stage I to IIA lung adenocarcinoma who had undergone definitive SBRT at our institution from August 2008 to August 2015 and had undergone core biopsy. Histologic subtyping was performed according to the 2015 World Health Organization classification. Of the 124 tumors, 37 (30%) were a high-risk subtype, defined as containing a component of solid and/or micropapillary pattern. The cumulative incidences of local, nodal, regional, and distant failure were compared between the high-risk and non–high-risk adenocarcinoma subtypes using Gray's test, and multivariable-adjusted hazard ratios (HRs) were estimated from propensity score–weighted Cox regression models. Results: The median follow-up for the entire cohort was 17 months and for surviving patients was 21 months. The 1-year cumulative incidence of and adjusted HR for local, nodal, regional, and distant failure in high-risk versus non–high-risk lesions was 7.3% versus 2.7% (HR 16.8; 95% confidence interval [CI] 3.5-81.4), 14.8% versus 2.6% (HR 3.8; 95% CI 0.95-15.0), 4.0% versus 1.2% (HR 20.9; 95% CI 2.3-192.3), and 22.7% versus 3.6% (HR 6.9; 95% CI 2.2-21.1), respectively. No significant difference was seen with regard to overall survival. Conclusions: The outcomes after SBRT for early-stage adenocarcinoma of the lung correlate highly with histologic subtype, with micropapillary and solid tumors portending significantly higher rates of locoregional and metastatic progression. In this context, the histologic subtype determined from core biopsies is a prognostic factor and could have important implications for patient selection, adjuvant treatment, biopsy methods, and clinical trial design.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Medical Device Recalls in Radiation Oncology: Analysis of US Food and Drug Administration Data, 2002-2015

Purpose: To analyze all recalls involving radiation oncology devices (RODs) from the US Food and Drug Administration (FDA)'s recall database, comparing these with non–radiation oncology device recalls to identify discipline-specific trends that may inform improvements in device safety. Methods and Materials: Recall data on RODs from 2002 to 2015 were sorted into 4 product categories (external beam, brachytherapy, planning systems, and simulation systems). Outcomes included determined cause of recall, recall class (severity), quantity in commerce, time until recall termination (date FDA determines recall is complete), and time since 510(k) approval. Descriptive statistics were performed with linear regression of time-series data. Results for RODs were compared with those for other devices by Pearson χ{sup 2} test for categorical data and 2-sample Kolmogorov-Smirnov test for distributions. Results: There were 502 ROD recalls and 9534 other class II device recalls during 2002 to 2015. Most recalls were for external beam devices (66.7%) and planning systems (22.9%), and recall events peaked in 2011. Radiation oncology devices differed significantly from other devices in all recall outcomes (P≤.04). Recall cause was commonly software related (49% vs 10% for other devices). Recall severity was more often moderate among RODs (97.6% vs 87.2%) instead of severe (0.2% vs 4.4%; P<.001). Time from 510(k) market approval to recall was shorter among RODs (P<.001) and progressively shortened over time. Radiation oncology devices had fewer recalled devices in commerce than other devices (P<.001). Conclusions: Compared with other class II devices, RODs experience recalls sooner after market approval and are trending sooner still. Most of these recalls were moderate in severity, and software issues are prevalent. Comprehensive analysis of recall data can identify areas for device improvement, such as better system design among RODs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Computerized System for Safety Verification of External Beam Radiation Therapy Planning

Purpose: To report an assessment of in-house software, Verifier, developed to improve efficacy and efficiency of the radiation therapy (RT) treatment planning process and quality control review (QCR). Methods and Materials: Radiation therapy plan parameters retrieved from our treatment planning database are used by automated tests to give 75 types of warnings, such as prescription and plan discrepancies. The software is continuously updated on the basis of new issues, ideas, and planning policies. Verifier was retrospectively assessed (2007-2015) by examining impact on treatment plan revisions, frequency of quality improvement incident reports of avoidable RT plan-related safety events, unaddressed issues, and staff efficiency. Results: Plan revisions for specific issues declined dramatically in response to implementation of corresponding Verifier tests. Between 2012 and 2015 our institution's total rate of plan revisions dropped from 18.0% to 11.2%. Between 2008 and 2015 specific tests were added to Verifier while the rate of corresponding avoidable safety events was reduced from 0.34% to 0.00% over the same period. Simulations suggest Verifier saves approximately 2 to 5 minutes per QCR. Conclusions: The decrease in quantifiable metrics of plan revisions and incident reports suggests automatic RT plan-checking software enhances patient safety and clinical efficiency. Although only modest time savings may be gained using Verifier for the QCR itself, the greater impact on efficiency is through avoiding late-stage plan modifications and improving documentation via automation. We encourage other institutions to consider working toward adding similar technologies to enhance their RT quality assurance programs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Detection and attribution of long-term and fine-scale changes in spring phenology over urban areas: A case study in New York State

Spring phenology plays an essential role in climate change, terrestrial ecosystem, and public health. Field-based monitoring and understanding of changes in spring phenology for long periods and in large regions are challenging due to the limited in-site observations. Space-based remotely sensed observations offer great potentials for monitoring decadal spring phenology changes from regional to global scales. However, the coarse-scale remotely sensed observations are insufficient to capture fine-scale spring phenology dynamics, especially in urban areas, and this makes it challenging for understanding the combined effects of climate change and urbanization on spring phenology. We derived the start of phenology season (SOS) in New York State using 30 m Landsat observations from 1990 to 2015 to understand the impact of the environment and urbanization on SOS. The results show that SOS for different years reveals heterogeneous spatial distribution. Most regions of New York State have been experiencing significant spring phenology changes in form of earlier onset of vegetation greening, ranging from 0.2 to 0.6 day/year during 1990 to 2015, and this trend varies slightly with latitudes and urbanization levels. Further, spatial correlation analysis shows that the increase in temperature and urbanization could both promote the advancement of SOS. However, the effect of urbanization (partial correlation coefficient (R) ranges from −0.289 to −0.542) on SOS is greater than the effect of temperature (R ranges from 0.006 to −0.192). The study generates a high spatio-temporal resolution spring phenology dataset for ecological, environmental and public health studies, especially in urban areas, and reveals the importance of better accounting for the urbanization effects when quantifying the SOS dynamics in phenology models.

Landsat↗

Effects of residue removal and tillage on greenhouse gas emissions in continuous corn systems as simulated with RZWQM2

Agricultural production is a major source of carbon dioxide (CO 2 ) and nitrous oxide (N 2 O) globally. The effects of conservation practices on soil CO 2 and N 2 O emissions remain a high degree of uncertainty. In this study, soil CO 2 and N 2 O emissions under different residue and tillage practices in an irrigated, continuous corn system, were investigated using the Root Zone Water Quality Model (RZWQM2). Combinations of no/high stover removal (NR and HR, respectively) and no-till/conventional tillage (NT and CT, respectively) field experiments were tested over the four crop-years (Apr. 2011–Apr. 2015). The model was calibrated using the NRCT, and validated with other treatments. The simulation results showed that soil volumetric water content (VWC) in the NR treatments (i.e., NRCT and NRNT) was 1.3%–1.9% higher than that in the HR treatments (i.e., HRCT and HRNT) averaged across the four years. A higher amount of CO 2 and N 2 O emissions were simulated in the NRCT across the four years (annual average: 7034 kg C/ha/yr for CO 2 and 3.8 kg N/ha/yr for N 2 O), and lower emissions were in the HRNT (annual average: 6329 kg C/ha/yr and 3.7 kg N/ha/yr for N 2 O). A long-term simulation (2001–2015) suggested that the CO 2 and N 2 O emissions were closely correlated with the stover removal degree (SRD), tillage, VWC, soil temperature (ST), years in management (Y), and fertilizer application. Stover and tillage practices had cumulative effects on CO 2 emissions. The simulated annual CO 2 emissions in 1st year from NRCT, NRNT, and HRCT were 7.8%, 0.0%, and 7.7% higher than that from HRNT, respectively; then the emissions in 15th year were 63.6%, 47.7%, and 29.1% higher, respectively. Meanwhile, there were no cumulative effects on N 2 O emissions. Furthermore, the results also demonstrated that the RZWQM2 is a promising tool for evaluating the long-term effects of CO 2 and N 2 O emissions on different conservation practices.

54 ENVIRONMENTAL SCIENCES↗

Effects of surface runoff and infiltration partition methods on hydrological modeling: A comparison of four schemes in two watersheds in the Northeastern US

The ratio according to which the precipitation/snowmelt is divided into surface and subsurface water is of primary importance to watershed scale hydrological modeling. The present study compared four different surface runoff and infiltration partition methods in the Richards-equation-based SWAT model (RSWAT), i.e., daily curve number method (DC-RSWAT), hourly curve number method (HC-RSWAT), Green-Ampt method (GA-RSWAT), and effective infiltration capacity method (EIC-RSWAT). These four versions of RSWAT and a daily-curve-number-based SWAT (DC-SWAT) were used to simulate daily flow rate (from 2001 to 2015) at the outlets of the Tuckahoe Creek Watershed (TCW) and Greensboro Watershed (GW) of the Chesapeake Bay in Maryland. Parameter sensitivity analysis, calibration, and prediction uncertainty analysis were conducted. The results indicate that surface runoff and infiltration partition methods have pronounced impacts on model performance. Comparative analysis showed that DC-RSWAT outperformed other versions of RSWAT for both calibration (from 2001 to2007) and validation (from 2008 to 2015) periods in the two test watersheds. In general, DC-RSWAT achieved more accurate deterministic flow simulation and reliable uncertainty estimation than other versions. As such, daily-curve-number method is recommended for surface runoff and infiltration partition in RSWAT for simulating stream flow.

hydrology, modeling, streamflow↗

The Global LAnd Surface Satellite (GLASS) evapotranspiration product Version 5.0: Algorithm development and preliminary validation

An accurate estimation of spatially and temporally continuous global terrestrial evapotranspiration (ET) is essential in the assessment of surface energy, water and carbon cycles. The Global LAnd Surface Satellite (GLASS) ET product Version 4.0 (v4.0) based on the Bayesian model averaging (BMA) method was generated to estimate global terrestrial ET. However, certain uncertainty for the GLASS ET product v4.0 limits its application. In this study, we introduced the deep neural networks (DNN) merging framework to improve terrestrial ET estimation for GLASS ET product Version 5.0 (v5.0) generation by integrating five satellite-derived ET products [Moderate Resolution Imaging Spectroradiometer (MODIS) ET product (MOD16), Shuttleworth–Wallace dual-source ET product (SW), Priestley–Taylor-based ET product (PT-JPL), modified satellite-based Priestley–Taylor ET product (MS-PT) and simple hybrid ET product (SIM)]. We compared the performance of DNN method against other merging methods, including GLASS ET algorithm v4.0 (BMA), the gradient boosting regression tree (GBRT) method and the random forest (RF) method, based on 195 global eddy covariance (EC) flux towers covering observations from 2000 through 2015. Validations indicated that the DNN had the highest accuracy among four merging methods across different land cover types, yielding the highest average determination coefficients (R 2 , 0.62), root-mean-squared-error (RMSE, 24.1 W/m 2 ) and Kling–Gupta efficiency (KGE, 0.77) with a of 99% confidence interval. Compared with GLASS ET algorithm v4.0, the DNN improved on the R 2 by approximately 7% (p < 0.01) and the KGE by 10%. Based on the DNN, we then generated 8-day GLASS ET product v5.0 globally with a 1 km spatial resolution from 2001 to 2015 driven by GLASS vegetation and surface net radiation (R n ) datasets and Modern-Era Retrospective Analysis for Research and Applications, Version 2 (MERRA2) datasets. Finally, this global terrestrial ET product provides a valuable dataset for monitoring regional and global water resources and environmental changes.

54 ENVIRONMENTAL SCIENCES↗

Microstructural processes in irradiated materials

This is an editorial article (preface) for the publication of symposium papers in the Journal of Nuclear materials: These proceedings contain the papers presented at two symposia, the Microstructural Processes in Irradiated Materials (MPIM) and Characterization of Nuclear Reactor Materials and Components with Neutron and Synchrotron Radiation, held in the TMS 2015, 144th Annual Meeting & Exhibition at Walt Disney World, Orlando, Florida, USA on March 15–19, 2015.

irradiation effect↗

Radiation damage and annealing in plutonium tetrafluoride

Plutonium tetrafluoride that was separated prior to 1966 at the Hanford Site in Washington State was analyzed at the Pacific Northwest National Laboratory (PNNL) in 2015 and 2016. The plutonium tetrafluoride, as received, was an off-normal color and considering the age of the plutonium, there were questions about the condition of the material. These questions had to be answered in order to determine the suitability of the material for future use or long-term storage. Therefore, Thermogravimetric/Differential Thermal Analysis and X-ray Diffraction evaluations were conducted to determine the plutonium’s crystal structure, oxide content, and moisture content; these analyses reported that the plutonium was predominately amorphous and tetrafluoride, with an oxide content near ten percent. Freshly fluorinated plutonium tetrafluoride is known to be monoclinic. During the initial Thermogravimetric/Differential Thermal analyses, it was discovered that an exothermic event occurred within the material near 414°C. X-ray Diffraction analyses were conducted on the annealed tetrafluoride. The X-ray Diffraction analyses indicated that some degree of recrystallization occurred in conjunction with the 414°C event. The following commentary describes the series of Thermogravimetric/Differential Thermal and X-ray Diffraction analyses that were conducted as part of this investigation at PNNL, in collaboration with the University of Utah Nuclear Engineering Program.

McCoy, Kaylyn↗

Preface

The 25 April 2015 Gorkha, Nepal earthquake of magnitude 7.8 devastated parts of Nepal and northern India with a death toll of more than 8000. Here, several aftershocks of moderate size were recorded, including one of M7.2 on 12 May 2015 on the eastern periphery of the main rupture.

Purnachandra Rao, N.↗

A comparative study for Hydrogen storage in metal decorated graphyne nanotubes and graphyne monolayers

A comparative study for hydrogen storage in metal decorated graphyne nanotubes and graphyne monolayers has been investigated within the framework of first-principle calculations. Our results show that the binding energies of Li, Ca, Sc, Ti on graphyne nanotubes are stronger than that on graphyne monolayers. Such strong binding would prevent the formation of metal clusters on graphyne nanotubes. From the charge transfer and partial density of states, it is found that the curvature effect of nanotubes plays an important role for the strong binding strength of metal on graphyne nanotubes. And the hydrogen storage capacity is 4.82 wt%, 5.08 wt%, 4.88 wt%, 4.76 wt% for Li, Ca, Sc, Ti decorated graphyne nanotubes that promise a potential material for storing hydrogen. - Graphical abstract: Metal atoms (Li, Ca, Sc and Ti) can strongly bind to graphyne nanotubes to avoid the formation of metal clusters, and a capacity of Ca@graphyne nanotube is 5.08 wt% which is close to the requirement of DOE in 2015. Twenty-four hydrogen molecules absorb to Ti-decorated graphyne nanotube. - Highlights: • The binding strength for metal on graphyne nanotubes is much stronger than that on γ-graphyne monolayer. • Metal atoms can strongly bind to the curving triangle acetylenes rings to avoid the formation of metal clusters. • A capacity of Ca@graphyne nanotube is 5.08 wt% which is close to the requirement of DOE in 2015.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Heart-sparing radiotherapy in patients with breast cancer: What are the techniques used in the clinical routine?

The aim of this study was to understand the practice of care in German-speaking countries with regard to heart-sparing radiotherapy techniques. Between August 2015 and September 2015, an e-mail/fax-based survey was sent to radiation oncology departments in Germany, Austria, and the German-speaking Switzerland. The questionnaire was divided into 3 chapters: a general chapter on the department, a chapter specific for heart-sparing techniques in patients with breast cancer, and a third chapter on personal beliefs on the topic of heart sparing in patients with breast cancer. A total of 82 radiation oncology departments answered the questionnaire: 16 university clinics and 66 other departments. In general, heart-sparing techniques are being offered by 90.2% of departments for radiation oncology in the German-speaking countries. However, in the clinical routine, 87.7% of institutions use heart-sparing techniques in less than 50% of patients with breast cancer. Heart-sparing techniques are especially provided for patients with left-sided breast cancer (80%), patients after mastectomy (52.5%), and when the mammaria interna lymph drainage vessels are irradiated (41.3%). In 46.3% of departments, there are written internal guidelines for heart sparing in patients with breast cancer. Breathing-adapted radiotherapy is used as the most frequent heart-sparing technique in 64.7% of the institutions, followed by intensity-modulated radiation therapy, which is most frequently used by 22.1%. The only significant difference between university hospitals and other departments was seen for the offering of partial breast irradiation. The most commonly used heart-sparing technique is breathing-adapted radiotherapy, but there is no coherent approach for heart sparing in patients with breast cancer in the German-speaking countries. Overall, all options for cardiac protection/cardiac avoidance have their advantages and disadvantages, with deep inspiration breath-hold radiotherapyhaving the most clear data, which should be the preferred choice when using heart-sparing techniques.

61 RADIATION PROTECTION AND DOSIMETRY↗

Modular focusing ring imaging Cherenkov detector for electron–ion collider experiments

A powerful new electron-ion collider (EIC) has been recommended in the 2015 Long Range Plan for Nuclear Science for probing the partonic structure inside nucleons and nuclei with unprecedented precision and versatility [1]. EIC detectors are currently under development [2], all of which require hadron identification over a broad kinematic range. A prototype ring imaging Cherenkov detector has been developed for hadron identification in the momentum range from 3 GeV/c to 10 GeV/c. The key feature of this new detector is a compact and modular design, achieved by using aerogel as radiator and a Fresnel lens for ring focusing. In this paper, the results from a beam test of a prototype device at Fermilab are reported.

aerogel↗

Refine your search to explore more results.