Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “zero carbon”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Feasibility of Measuring Mean Vertical Motion for Estimating Advection

Numerous recent studies calculate horizontal and vertical advection terms for budget studies of net ecosystem exchange of carbon. One potential uncertainty in such studies is the estimate of mean vertical motion. This work addresses the reliability of vertical advection estimates by contrasting the vertical motion obtained from the standard practise of measuring the vertical velocity and applying a tilt correction, to the vertical motion calculated from measurements of the horizontal divergence of the flow using a network of towers. Results are compared for three different tilt correction methods. Estimates of mean vertical motion are sensitive to the choice of tilt correction method. The short-term mean (10 to 60 minutes) vertical motion based on the horizontal divergence is more realistic compared to the estimates derived from the standard practise. The divergence shows long-term mean (days to months) sinking motion at the site, apparently due to the surface roughness change. Because all the tilt correction methods rely on the assumption that the long-term mean vertical motion is zero for a given wind direction, they fail to reproduce the vertical motion based on the divergence.

Vickers, Dean↗

Aligned Carbon Nanotube Tape for Sensor Applications

For this effort, will concentrate on three applications: Vibration Gyroscope utilizes piezoelectric properties of the tape and Coriolis effect Accelerometer utilizes the piezoresistive property Strain Gauge utilizes piezoresistive property Accelerometer and Strain Gauge can also utilize piezoelectric effect Test piezoelectric properties using facilities at the Microfabrication Laboratory (AMRDEC) . Enhance piezoelectric effect using polyvinylidine fluoride and P(VDF ]TrFE) which is readily polarizable .Spray matrix solution while winding fiber; Sandwich of CNT tape and PVDF film (DOE .Two Level) . Construct and test prototype vibration gyroscope . Construct and test prototype accelerometer using cantilever design . Test strain sensitivity of CNT tape against industrial strain gauge . Embed CNT tape in composite samples as well as on surface and test to failure (4 ]point bend) A piezoelectric device exhibits an electrical response from a mechanical applied stress. . A piezoelectric device has both capacitance and resistance properties in which by applying an electric field from a waveform will exert a mechanical stress that can be monitored for a response. . The typical waveform applied is a sinusoidal waveform of a defined voltage for a defined period. The defined voltage is driven from 0 volts to the positive defined volts then back to 0 and driven to negative defined volts then back to 0. . Example. Vmax set to 10V and period set to 10 ms. . Voltage will start at zero, go to 10 volts, return to zero, go to ]10 volts and return to zero during 10 ms. . Applying this electrical field to a DUT, the capacitance response and resistance response can be observed. CNT tape is easier to manufacture and cheaper than micromachining silicon or other ceramic piezoelectric used in gyroscopes and accelerometers CNT tape properties can be modified during manufacture for specific application CNT tape has enhanced mechanical and thermal properties in addition to unique electrical properties CNT tape as a strain gauge in Structural Health Monitoring will provide an excellent material to embed within composite structures

Tucker, Dennis S.↗

Marangoni-Benard Convection in a Evaporating Liquid Thin Layer

Marangoni-Benard convection in evaporating liquid thin layers has been investigated through flow visualization and temperature profile measurement. Twelve liquids, namely ethyl alcohol, methanol, chloroform, acetone, cyclohexane, benzine, methylene chloride, carbon tetrachloride, ethyl acetate, n-pentane, silicone oil (0.65 cSt.), and freon-113, were tested and convection patterns in thin layers of these samples were observed. Comparison among these tested samples shows that some liquids are sensitive to surface contamination from aluminum powder but some are not. The latter is excellent to be used for the investigation of surface-tension driven convection through visualization using the tracer. Two sample liquids, alcohol and freon-113 were particularly selected for systematic study. It was found that the wavelength of Benard cells would not change with thickness of the layer when it evaporates at room temperature. Special attention was focused on cases in which a liquid layer was cooled from below, and some interesting results were obtained. Convection patterns were recorded during the evaporation process and the patterns at certain time frame were compared. Benard cells were observed in thin layers with a nonlinear temperature profile and even with a zero or positive temperature gradient. Wavelength of the cells was found to increase as the evaporation progressed.

Chai, An-Ti↗

Magnetism of Carbonados

Carbonados are porous polycrystalline (with crystal sizes up to 100 micrometer) diamonds. Carbonado is found only in alluvial deposits in Bahia, Brazil and in the Central African Republic (CAR). Alluvial deposit host is 1.5 Ga while the carbonados are between 2.6 - 3.8 Ga. The process of fusing the carbonado microcrystals together is not fully understood, partly due to fact that the origin of these carbonado, is not known. Several modes of origins are proposed for carbonado. First, a crustal origin. Carbonados have a light carbon and helium isotopic signature. They contain an enrichment of the rare-earth elements (REE). Carbonados have tightly trapped atmospheric noble gases and contain an evidence of high He content despite the carbonado expected depletion of He at mantle temperatures. Carbonados have high porosity incompatible with high pressure mantle conditions. Second, a mantle origin is proposed based on similar REE pattern to kimberlites. The presence of nitrogen platelet (by IR spectra) indicates high temperature origin and syngenetic inclusions of rutile, ilmenite, and magnetite indicates high pressure and high temperature conditions consistent with mantle origin as well. Third, it is proposed that carbonado diamonds are a result of early impacts into crustal rocks. This is indicated by the rare and controversial occurrence of high pressure diamond polymorph, londsdaleite, frequently found in diamonds from meteorite impact sites, and by observation of planar deformation features, possibly indicating shock events. Finally, it is suggested that carbonados have an extraterrestrial origin, as indicated by a long term annealing based on observation of a zero-phonon line, attributed to paired nitrogen atoms in association with a vacancy.

Kletetschka, G.↗

Energy yields in the prebiotic synthesis of hydrogen cyanide and formaldehyde

Prebiotic experiments are usually reported in terms of carbon yields, i.e., the yield of product based on the total carbon in the system. These experiments usually involve a large input of energy and are designed to maximize the yields of product. However, large inputs of energy result in multiple activation of the reactants and products. A more realistic prebiotic experiment is to remove the products of the activation step so they are not exposed a second time to the energy source. This is equivalent to transporting the products synthesized in the primitive atmosphere to the ocean, and thereby protecting them from destruction by atmospheric energy sources. Experiments of this type, using lower inputs of energy, give energy yields (moles of products/joule) which can be used to estimate the relative importance of the different energy sources on the primitive earth. Simulated prebiotic atmospheres containing either CH4, CO or CO2 with N2, H2O and variable amounts of H2 were subjected to a high frequency Tesla coil. Samples of the aqueous phase were taken at various time intervals from 1 hr to 7 days, and the energy yields were obtained by extrapolation to zero time. The samples were analyzed for HCN with the cyanide electrode and for H2CO by chromotropic acid. The spark energy was estimated by calorimetry. The temperature rise in an insulated discharge flask was compared with the temperature rise from a resistance heater in the same flask. These results will be compared with calculated production rates of HCN and H2CO from lightning and a number of photochemical processes on the primitive Earth.

Stribling, R.↗

A New Formation Mechanism for the Hottest Horizontal-Branch Stars

Hot subluminous stars lying up to 0.7 mag below the extreme horizontal branch (EHB) are found in the ultraviolet color-magnitude diagrams (CMDs) of both omega Cen and NGC 2808. In order to investigate the origin of these subluminous stars, we have constructed a detailed set of evolutionary sequences that follow the evolution of low-mass stars continuously from the zero-age main sequence through the helium-core flash to the HB for a wide range in the mass loss along the red-giant branch (RGB). Stars with the largest mass loss evolve off the RGB to high effective temperatures before igniting helium in their cores. Our results indicate that the subluminous EHB stars, as well as the high temperature gap along the EHB of NGC 2808, can be explained if these stars undergo a late helium-core flash while descending the white-dwarf cooling curve. Under these conditions the convection zone produced by the main helium flash will penetrate into the stellar envelope, thereby mixing most, if not all, of the envelope hydrogen into the hot helium-burning interior, where it is rapidly consumed. This phenomenon is analogous to the 'born-again' scenario for producing hydrogen-deficient stars following a very late helium-shell flash. This 'flash mixing' of the envelope during a late helium-core flash greatly enhances the envelope helium and carbon abundances and, as a result, leads to a discontinuous increase in the HB effective temperature. We argue that the hot HB gap observed in NGC 2808 is associated with this theoretically predicted dichotomy in the RB properties. Using new helium- and carbon-rich stellar atmospheres, we show that the changes in the envelope abundances due to flash mixing will suppress the ultraviolet flux in the spectra of hot EHB stars. We suggest that such changes in the emergent spectral energy distribution are primarily responsible for explaining the hot subluminous EHB stars in omega Cen and NGC 2808. Moreover, we demonstrate that models without flash mixing lie, at most, only approximately 0.1 mag below the EHB, and hence fail to explain the observations.

Sweigart, Allen V.↗

The Origin of Hot Subluminous Horizontal-Branch Stars in Omega Centauri and NGC 2808

Hot subluminous stars lying up to 0.7 mag below the extreme horizontal branch (EHB) are found in the ultraviolet color-magnitude diagrams of both omega Cen (DCruz et.al. 2000) and NGC 2808 (Brown et al. 2001). In order to investigate the origin of these subluminous stars, we have constructed a detailed set of evolutionary sequences that follow the evolution of low-mass stars continuously from the zero-age main sequence through the helium-core flash to the HB for a wide range in the mass loss along the red-giant branch (RGB). Stars with the largest mass loss evolve off the RGB to high effective temperatures before igniting helium in their cores (Castellani & Castellani 1993). Our results indicate that the location of the subluminous EHB stars, as well as the high temperature gap along the EHB of NGC 2808, can be explained if these stars undergo a late helium-core flash while descending the white-dwarf cooling curve. Under these conditions the convection zone produced by the main helium flash will penetrate into the stellar envelope, thereby mixing most, if not all, of the envelope hydrogen into the hot helium-burning interior, where it is rapidly consumed (Sweigart 1997). This phenomenon is analogous to the "born-again" scenario for producing hydrogen-deficient stars following a very late helium-shell flash. This "flash mixing" of the envelope during a late helium-core flash greatly enhances the envelope helium and carbon abundances and, as a result, leads to a discontinuous increase in the HB effective temperature. We argue that the hot HB gap observed in NGC 2808 is associated with this theoretically predicted dichotomy in the HB properties. Using new helium- and carbon-rich stellar atmospheres, we show that the changes in the envelope abundances due to flash mixing will suppress the ultraviolet flux in the spectra of hot EHB stars. We suggest that such changes in the emergent spectral energy distribution are primarily responsible for explaining the hot subluminous EHB stars in omega Cen and NGC 2808. Moreover, we demonstrate that models without flash mixing lie, at most, only approximately 0.1 mag below the EHB, and hence fail to explain the observations.

Sweigart, Allen V.↗

Atmosphere-biosphere exchange flux of carbon dioxide in a tallgrass prairie modeled with satellite spectral data

The estimation of the rate of net CO2 uptake of vegetated land surfaces is essential for studies of global carbon cycle. The present paper demonstrates the use of spectral reflectance data from satellite remote sensing to model net CO2 flux (NCF) of a tallgrass canopy at the Konza prairie, Kansas. A bidirectional reflectance canopy model was used to estimate seasonal changes in canopy leaf area index (LAI) from surface reflectances remotely sensed by SPOT 1 and Landsat 5 satellites. The radiation model was also coupled with leaf conductance-photosynthesis models to scale up stomatal conductance and NCF from individual leaves to canopy level according to radiation distribution inside the canopy. The satellite-data-driven model was able to closely simulate the seasonal change in LAI as well as the short-term variation of canopy LAI caused by the dry period during late July and early August in the area. Modeled canopy stomatal conductance (g(sub c)) and NCF agree with measurements within 0.16 cm/s and 0.28 mg m(exp -2)/s, respectively, during the growth season from late May to late August. In October both measured and modeled NCF turned to small negative values as canopy photosynthesis diminished and predicted LAI approached zero. In addition to data scatter, some of the differences between modeled and measured g(sub c) and NCF may be attributed to uncertainties in seasonal changes of plant physiological status that were not detected by satellite data; some of the differences were caused by inadequate description of the dependence of nighttime CO2 flux of soil respiration on near-surface turbulent mixing.

Gao, W.↗

Noninvasive, near infrared spectroscopic-measured muscle pH and PO2 indicate tissue perfusion for cardiac surgical patients undergoing cardiopulmonary bypass

OBJECTIVE: To determine whether near infrared spectroscopic measurement of tissue pH and Po2 has sufficient accuracy to assess variation in tissue perfusion resulting from changes in blood pressure and metabolic demand during cardiopulmonary bypass. DESIGN: Prospective clinical study. SETTING: Academic medical center. SUBJECTS: Eighteen elective cardiac surgical patients. INTERVENTION: Cardiac surgery under cardiopulmonary bypass. MEASUREMENTS AND MAIN RESULTS: A near infrared spectroscopic fiber optic probe was placed over the hypothenar eminence. Reference Po2 and pH sensors were inserted in the abductor digiti minimi (V). Data were collected every 30 secs during surgery and for 6 hrs following cardiopulmonary bypass. Calibration equations developed from one third of the data were used with the remaining data to investigate sensitivity of the near infrared spectroscopic measurement to physiologic changes resulting from cardiopulmonary bypass. Near infrared spectroscopic and reference pH and Po2 measurements were compared for each subject using standard error of prediction. Near infrared spectroscopic pH and Po2 at baseline were compared with values during cardiopulmonary bypass just before rewarming commenced (hypotensive, hypothermic), after rewarming (hypotensive, normothermic) just before discontinuation of cardiopulmonary bypass, and at 6 hrs following cardiopulmonary bypass (normotensive, normothermic) using mixed-model analysis of variance. Near infrared spectroscopic pH and Po2 were well correlated with the invasive measurement of pH (R2 =.84) and Po2 (R 2 =.66) with an average standard error of prediction of 0.022 +/- 0.008 pH units and 6 +/- 3 mm Hg, respectively. The average difference between the invasive and near infrared spectroscopic measurement was near zero for both the pH and Po2 measurements. Near infrared spectroscopic Po2 significantly decreased 50% on initiation of cardiopulmonary bypass and remained depressed throughout the bypass and monitored intensive care period. Near infrared spectroscopic pH decreased significantly during cardiopulmonary bypass, decreased significantly during rewarming, and remained depressed 6 hrs after cardiopulmonary bypass. Diabetic patients responded differently than nondiabetic subjects to cardiopulmonary bypass, with lower muscle pH values (p =.02). CONCLUSIONS: Near infrared spectroscopic-measured muscle pH and Po2 are sensitive to changes in tissue perfusion during cardiopulmonary bypass.

Non-NASA Center↗

Continued Advancement of Supported Liquid Membranes for Carbon Dioxide Control in Extravehicular Activity Applications

The Development of a new, robust, portable life support system (PLSS) is currently a high NASA priority in order to support longer and safer extravehicular activity (EVA) missions that will be necessary as space travel extends to near-Earth asteroids and eventually Mars. One of the critical PLSS functions is maintaining the carbon dioxide (CO2) concentration in the suit at acceptable levels. The Metal Oxide (MetOx) canister has a finite CO2 adsorption capacity and therefore in order to extend mission times, the unit would have to be larger and heavier, which is undesirable; therefore new CO2 control technologies must be developed. While recent work has centered on the use of alternating sorbent beds that can be regenerated during the EVA, this strategy increases the system complexity and power consumption. A simpler approach is to use a membrane that vents CO2 to space but retains oxygen(O2). A membrane has many advantages over current technology: it is a continuous system with no theoretical capacity limit, it requires no consumables, and it requires no hardware for switching beds between absorption and regeneration. Conventional gas separation membranes do not have adequate selectivity for use in the PLSS, but the required performance could be obtained with a supported liquid membrane (SLM), which consists of a microporous film filled with a liquid that selectively reacts with CO2 over oxygen (O2). In a recently completed Phase II Small Business Innovative Research project, Reaction Systems developed a new reactive liquid that has effectively zero vapor pressure, making it an ideal candidate for use in an SLM. Results obtained with the SLM in a flat sheet configuration with representative pressures of CO2, O2, and water (H2O) have shown that the CO2 permeation rate and CO2/O2 selectivity requirements have been met. In addition, the SLM vents moisture to space very effectively. The SLM has also been prepared and tested in a hollow fiber form, which will be necessary to meet size requirements in the PLSS. In initial tests, the required CO2 permeance values have been obtained, while the current CO2/O2 selectivity values are somewhat lower than needed. However, the performance of the SLM is a strong function of the method used to impregnate the sorbent in the hollow fiber walls and rapid progress is being made in that area.

Wickham, David T.↗

Advanced Supported Liquid Membranes for CO2 Control in Extravehicular Activity Applications

Developing a new, robust, portable life support system (PLSS) is currently a high priority for NASA in order to support longer and safer extravehicular activity (EVA) missions. One of the critical PLSS functions is maintaining the carbon dioxide (CO2) concentration in the suit at acceptable levels. Although the Metal Oxide (MetOx) canister has worked well, it has a finite CO2 adsorption capacity. Consequently, the unit would have to be larger and heavier to extend EVA times. Therefore, new CO2 control technologies must be developed to meet mission objectives without increasing the size of the PLSS. Although recent work has centered on sorbents that can be regenerated during the EVA, this strategy increases the system complexity and power consumption. A simpler approach is to use a membrane that selectively vents CO2 to space. A membrane has many advantages over current technology: it is a continuous system with no theoretical capacity limit, it requires no consumables, and it requires no hardware for switching beds between absorption and regeneration. Unfortunately, conventional gas separation membranes do not have adequate selectivity for use in the PLSS. However, the required performance could be obtained with a supported liquid membrane (SLM), which consists of a micro porous material filled with a liquid that selectively reacts with CO2 over oxygen (O2). In a current Phase II SBIR project, Reaction Systems has developed a new reactive liquid, which has effectively zero vapor pressure making it an ideal candidate for use in an SLM. The SLM function has been demonstrated with representative pressures of CO2, O2, and water (H2O). In addition to being effective for CO2 control, the SLM also vents moisture to space. Therefore, this project has demonstrated the feasibility of using an SLM to control CO2 in an EVA application. 1 President

Wickham, David T.↗

Advanced Supported Liquid Membranes for CO2 Control in Extravehicular Activity Applications

Developing a new, robust, portable life support system (PLSS) is currently a high priority for NASA in order to support longer and safer extravehicular activity (EVA) missions. One of the critical PLSS functions is maintaining the carbon dioxide (CO2) concentration in the suit at acceptable levels. Although the Metal Oxide (MetOx) canister has worked well, it has a finite CO2 adsorption capacity. Consequently, the unit would have to be larger and heavier to extend EVA times. Therefore, new CO2 control technologies must be developed to meet mission objectives without increasing the size of the PLSS. Although recent work has centered on sorbents that can be regenerated during the EVA, this strategy increases the system complexity and power consumption. A simpler approach is to use a membrane that selectively vents CO2 to space. A membrane has many advantages over current technology: it is a continuous system with no theoretical capacity limit, it requires no consumables, and it requires no hardware for switching beds between absorption and regeneration. Unfortunately, conventional gas separation membranes do not have adequate selectivity for use in the PLSS. However, the required performance could be obtained with a supported liquid membrane (SLM), which consists of a micro porous material filled with a liquid that selectively reacts with CO2 over oxygen (O2). In a current Phase II SBIR project, Reaction Systems has developed a new reactive liquid, which has effectively zero vapor pressure making it an ideal candidate for use in an SLM. The SLM function has been demonstrated with representative pressures of CO2, O2, and water (H2O). In addition to being effective for CO2 control, the SLM also vents moisture to space. Therefore, this project has demonstrated the feasibility of using an SLM to control CO2 in an EVA application.

Wickham, David T.↗

Passivation of Flexible YBCO Superconducting Current Lead With Amorphous SiO2 Layer

Adiabatic demagnetization refrigerators (ADR) are operated in space to cool detectors of cosmic radiation to a few 10s of mK. A key element of the ADR is a superconducting magnet operating at about 0.3 K that is continually energized and de-energized in synchronism with a thermal switch, such that a piece of paramagnetic salt is alternately warm in a high magnetic field and cold in zero magnetic field. This causes the salt pill or refrigerant to cool, and it is able to suck heat from an object, e.g., the sensor, to be cooled. Current has to be fed into and out of the magnets from a dissipative power supply at the ambient temperature of the spacecraft. The current leads that link the magnets to the power supply inevitably conduct a significant amount of heat into the colder regions of the supporting cryostat, resulting in the need for larger, heavier, and more powerful supporting refrigerators. The aim of this project was to design and construct high-temperature superconductor (HTS) leads from YBCO (yttrium barium copper oxide) composite conductors to reduce the heat load significantly in the temperature regime below the critical temperature of YBCO. The magnet lead does not have to support current in the event that the YBCO ceases to be superconducting. Cus - tomarily, a normal metal conductor in parallel with the YBCO is a necessary part of the lead structure to allow for this upset condition; however, for this application, the normal metal can be dispensed with. Amorphous silicon dioxide is deposited directly onto the surface of YBCO, which resides on a flexible substrate. The silicon dioxide protects the YBCO from chemically reacting with atmospheric water and carbon dioxide, thus preserving the superconducting properties of the YBCO. The customary protective coating for flexible YBCO conductors is silver or a silver/gold alloy, which conducts heat many orders of magnitude better than SiO2 and so limits the use of such a composite conductor for passing current across a thermal gradient with as little flow of heat as possible to make an efficient current lead. By protecting YBCO on a flexible substrate of low thermal conductivity with SiO2, a thermally efficient and flexible current lead can be fabricated. The technology is also applicable to current leads for 4 K superconducting electronics current biasing. A commercially available thin-film YBCO composite tape conductor is first stripped of its protective silver coating. It is then mounted on a jig that holds the sample flat and acts as a heat sink. Silicon dioxide is then deposited onto the YBCO to a thickness of about 1 micron using PECVD (plasma-enhanced chemical vapor deposition), without heating the YBCO to the point where degradation occurs. Since SiO2 can have good high-frequency electrical properties, it can be used to coat YBCO cable structures used to feed RF signals across temperature gradients. The prime embodiment concerns the conduction of DC current across the cryogenic temperature gradient. The coating is hard and electrically insulating, but flexible.

Johannes, Daniel↗

Dissolved gases in perennially ice-covered lakes of the McMurdo Dry Valleys, Antarctica

Measurements of dissolved N2, O2, Ar, CO2, and CH4 were made in perennially ice-covered Lake Hoare. Results confirm previous reports that O2 concentrations in the upper water column exceed atmospheric equilibrium and that N2 and Ar are supersaturated throughout the water column. The mean supersaturation of N2 was found to be 2.0 (+/- 0.37) and Ar was 3.8 (+/- 1.1). The ratios of N2/Ar (20.3 +/- 13.8), and O2/Ar (22.5 +/- 4.0) at the ice-water interface are consistent with those previously measured, suggesting that bubble formation is the main process for removing gas from the lake. However, the saturations of N2 and Ar greatly exceed those previously predicted for degassing by bubble formation only at the ice-water interface. The data support the hypothesis that removal of gas by bubbles occurs in the water column to a depth of 11 m in Lake Hoare. CO2 concentration increases from near zero at the ice-water interface to 80-100 times saturation at and below the chemocline at c. 28 m. There is considerable variability in the gas concentrations throughout the water column; samples separated in depth by one metre may vary by more than 50% in gas content. It is likely that this phenomenon results from the lack of turbulent mixing in the water column. Methane (c. 2 micrograms l-1) was detected below the chemocline and immediately above the sediment/water interface at a depth of 30 m. Samples from lakes Vanda, Joyce, and Miers, also show supersaturations of O2, N2, and Ar at levels similar to levels found in Lake Hoare.

NASA Discipline Exobiology↗

NASA Tech Briefs, January 2011

The topics include: 1) Distributed Aerodynamic Sensing and Processing Toolbox; 2) Collaborative Supervised Learning for Sensor Networks; 3) Hazard Detection Software for Lunar Landing; 4) Onboard Nonlinear Engine Sensor and Component Fault Diagnosis and Isolation Scheme; 5) Network-Capable Application Process and Wireless Intelligent Sensors for ISHM; 6) Interface Supports Multiple Broadcast Transceivers for Flight Applications; 7) FPGA Sequencer for Radar Altimeter Applications; 8) Miniature Sapphire Acoustic Resonator - MSAR; 9) Process-Hardened, Multi-Analyte Sensor for Characterizing Rocket Plume Constituents; 10) SAD5 Stereo Correlation Line-Striping in an FPGA; 11) Hybrid Composite Cryogenic Tank Structure; 12) Nanoscale Deformable Optics; 13) Reliability-Based Design Optimization of a Composite Airframe Component; 14) Zinc Oxide Nanowire Interphase for Enhanced Lightweight Polymer Fiber Composites; 15) Plasma Igniter for Reliable Ignition of Combustion in Rocket Engines; 16) Wire Test Grip Fixture; 17) A Sub-Hertz, Low-Frequency Vibration Isolation Platform; 18) Carbon Nanofibers Synthesized on Selective Substrates for Nonvolatile Memory and 3D Electronics; 19) Nanoparticle/Polymer Nanocomposite Bond Coat or Coating; 20) High-Resolution Wind Measurements for Offshore Wind Energy Development; 21) Spring Tire; 22) Marsviewer 2008; 23) Mission Services Evolution Center Message Bus; 24) Major Constituents Analysis for the Vehicle Cabin Atmosphere Monitor; 25) Astronaut Health Participant Summary Application; 26) Adaption of the AMDIS Method to Flight Status on the VCAM Instrument; 27) Natural Language Interface for Safety Certification of Safety-Critical Software; 28) Cryogenic Caging for Science Instrumentation; 29) Wide-Range Neutron Detector for Space Nuclear Applications; 30) In Situ Guided Wave Structural Health Monitoring System; 31) Multiplexed Energy Coupler for Rotating Equipment; 32) Attitude Estimation in Fractionated Spacecraft Cluster Systems; 33) Full Piezoelectric Multilayer-Stacked Hybrid Actuation/Transduction Systems; 34) Active Flow Effectors for Noise and Separation Control; 35) Method and System for Temporal Filtering in Video Compression Systems; 36) Apparatus for Measuring Total Emissivity of Small, Low-Emissivity Samples; 37) Multiple-Zone Diffractive Optic Element for Laser Ranging Applications; 38) Simplified Architecture for Precise Aiming of a Deep-Space Communication Laser Transceiver; 39) Two-Photon-Absorption Scheme for Optical Beam Tracking; 40) High-Sensitivity, Broad-Range Vacuum Gauge Using Nanotubes for Micromachined Cavities; 41) Wide-Field Optic for Autonomous Acquisition of Laser Link; 42) Extracting Zero-Gravity Surface Figure of a Mirror; 43) Modeling Electromagnetic Scattering From Complex Inhomogeneous Objects; 44) Visual Object Recognition and Tracking of Tools; 45) Method for Implementing Optical Phase Adjustment; 46) Visual SLAM Using Variance Grid Maps; 47) Rapid Calculation of Spacecraft Trajectories Using Efficient Taylor Series Integration; 48) Efficient Kriging Algorithms; 49) Predicting Spacecraft Trajectories by the WeavEncke Method; 50) An Augmentation of G-Guidance Algorithms; 51) Comparison of Aircraft Icing Growth Assessment Software; 52) Silicon-Germanium Voltage-Controlled Oscillator at 105 GHz; 53) Estimation of Coriolis Force and Torque Acting on Ares-1; 54) Null Lens Assembly for X-Ray Mirror Segments; and 55) High-Precision Pulse Generator.

Source record↗

FETs Based on Doped Polyaniline/Polyethylene Oxide Fibers

A family of experimental highly miniaturized field-effect transistors (FETs) is based on exploitation of the electrical properties of nanofibers of polyaniline/ polyethylene oxide (PANi/PEO) doped with camphorsulfonic acid. These polymer-based FETs have the potential for becoming building blocks of relatively inexpensive, low-voltage, highspeed logic circuits that could supplant complementary metal oxide/semiconductor (CMOS) logic circuits. The development of these polymerbased FETs offers advantages over the competing development of FETs based on carbon nanotubes. Whereas it is difficult to control the molecular structures and, hence, the electrical properties of carbon nanotubes, it is easy to tailor the electrical properties of these polymerbased FETs, throughout the range from insulating through semiconducting to metallic, through choices of doping levels and chemical manipulation of polymer side chains. A further advantage of doped PANi/PEO nanofibers is that they can be made to draw very small currents and operate at low voltage levels, and thus are promising for applications in which there are requirements to use many FETs to obtain large computational capabilities while minimizing power demands. Fabrication of an experimental FET in this family begins with the preparation of a substrate as follows: A layer of silicon dioxide between 50 and 200 nm thick is deposited on a highly doped (resistivity 0.01 W.cm) silicon substrate, then gold electrodes/contact stripes are deposited on the oxide. Next, one or more fibers of camphorsulphonic acid-doped PANi/PEO having diameters of the order of 100 nm are electrospun onto the substrate so as to span the gap between the gold electrodes (see Figure 1). Figure 2 depicts measured current-versus-voltage characteristics of the device of Figure 1, showing that saturation channel currents occur at source-todrain potentials that are surprisingly low, relative to those of CMOS FETs. The hole mobility in the depletion regime in this transistor was found to be 1.4 10(exp -4) sq cm/(V.s), while the one-dimensional charge density at zero gate bias was estimated to be approximately one hole per 50 two-ring repeat units of polyaniline, consistent with the rather high channel conductivity (approx. 10(exp -3) S/cm). Reducing or eliminating the PEO content of the fibers is expected to enhance the properties of future versions of this transistor.

Theofylaktos, Noulie↗

ANALYSIS OF THE MSL/MEDLI ENTRY DATA WITH COUPLED CFD AND MATERIAL RESPONSE.

The Mars Science Laboratory (MSL) was protected during its atmospheric entry by an instrumented heat-shield using NASA's Phenolic Impregnated Carbon Ablator (PICA) material. PICA is a lightweight carbon fiber/polymeric resin material that offers out-standing performances for protecting probes during planetary entry. The Mars Entry Descent and Landing Instrument (MEDLI) suite on MSL offers unique in-flight validation data for models of material response and atmospheric entry. MEDLI recorded, among other things, time-resolved in-depth temperature data of PICA using thermocouple sensors assembled in the MEDLI Integrated Sensor Plugs (MISP). The objective of this work is to showcase and analyze the coupling between the material response and the aerothermal environment. As shown in Figure 1, the workflow is divided into the following steps. First, the aerothermal properties are computed in the Data Parallel Line Relaxation (DPLR) code [3] and used with the Nonequilibrium air radiation (NEQAIR) program [8] to compute radiative heating. Second, the thermal response inside the material is computed in the Porous material Analysis Toolbox based on Open-FOAM (PATO) using a fixed blowing correction parameter. Third, the pyrolysis gases computed in PATO are used as inputs to a blowing boundary condition within DPLR. Fourth, the new environment properties from DPLR are used in NEQAIR to provide an updated solution, then both the updated aerothermal environment and radiative heating are used in PATO without blowing correction. The third and fourth steps are then repeated until convergence in surface temperature is obtained. Convergence in the radiative heating is generally achieved before surface temperature, at which point the radiative heating is no longer updated. Char mass loss rates are forced to zero to produce a non-receding surface condition. For early time points in the trajectory, where flow around the MSL aeroshell is rarefied, the Direct Simulation Monte Carlo (DSMC) code, SPARTA, is used to compute the aerothermal environment. Iteration between PATO and SPARTA is not performed due to the computational cost of DSMC simulations. Preliminary results of the coupling between PATO and DPLR for the MSL heatshield atmospheric entry model are presented in Figures 2-4 at 65 seconds after entry interface. Figure 2 shows the surface temperature results from an uncoupled simulation in PATO with the blowing correction parameter applied (left) along with the coupled surface temperature after iteration (right). Figure 3 shows the surface temperature along the centerline from windward to leeward for easier comparison. Figure 4 shows the coupled and uncoupled pyrolysis gas blowing rate. Mars 2020 used a similar heatshield consisting of PICA for thermal protection during entry, descent, and landing. In preparation for Mars 2020 post-flight analysis, the predictive material response capability is benchmarked against flight data from MEDLI. This work represents an important milestone toward the development of validated predictive capabilities for designing thermal protection systems for planetary probes.

Mars Science Laboratory↗

Analysis of MSL/MEDLI Entry Data with Coupled CFD and Material Response

The Mars Science Laboratory (MSL) was protected during its atmospheric entry by an instrumented heatshield using NASA's Phenolic Impregnated Carbon Ablator (PICA) material [1]. PICA is a lightweight carbon fiber/polymeric resin material that offers outstanding performances for protecting probes during planetary entry. The Mars Entry Descent and Landing Instrument (MEDLI) suite on MSL offers unique in-flight validation data for models of material response and atmospheric entry. MEDLI recorded, among other things, time-resolved in-depth temperature data of PICA using thermocouple sensors assembled in the MEDLI Integrated Sensor Plugs (MISP) [2]. The objective of this work is to showcase and analyze the coupling between the material response and the aerothermal environment. As shown in Figure 1, the workflow is divided into the following steps. First, the aerothermal properties are computed in the Data Parallel Line Relaxation (DPLR) code [3] and used with the Nonequilibrium air radiation (NEQAIR) program [8] to compute radiative heating. Second, the thermal response inside the material is computed in the Porous material Analysis Toolbox based on OpenFOAM (PATO) [4,5,6] using a fixed blowing correction parameter. Third, the pyrolysis gases computed in PATO are used as inputs to a blowing boundary condition within DPLR. Fourth, the new environment properties from DPLR are used in NEQAIR to provide an updated solution, then both the updated aerothermal environment and radiative heating are used in PATO without blowing correction. The third and fourth steps are then repeated until convergence in surface temperature is obtained. Convergence in the radiative heating is generally achieved before surface temperature, at which point the radiative heating is no longer updated. Char mass loss rates are forced to zero to produce a non-receding surface condition. For early time points in the trajectory, where flow around the MSL aeroshell is rarefied, the Direct Simulation Monte Carlo (DSMC) code, SPARTA [7], is used to compute the aerothermal environment. Iteration between PATO and SPARTA is not performed due to the computational cost of DSMC simulations. Preliminary results of the coupling between PATO and DPLR for the MSL heatshield atmospheric entry model are presented in Figures 2-4 at 65 seconds after entry interface. Figure 2 shows the surface temperature results from an uncoupled simulation in PATO with the blowing correction parameter applied (left) along with the coupled surface temperature after iteration (right). Figure 3 shows the surface temperature along the centerline from windward to leeward for easier comparison. Figure 4 shows the coupled and uncoupled pyrolysis gas blowing rate. Mars 2020 used a similar heatshield consisting of PICA for thermal protection during entry, descent, and landing. In preparation for Mars 2020 post-flight analysis, the predictive material response capability is benchmarked against flight data from MEDLI. This work represents an important milestone toward the development of validated predictive capabilities for designing thermal protection systems for planetary probes.

Thermal Protection Systems↗