Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “x-ray detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

The X-ray Integral Field Unit at the end of the Athena reformulation phase

The Athena mission entered a redefinition phase in July 2022, driven by the imperative to reduce the mission cost at completion for the European Space Agency below an acceptable target, while maintaining the flagship nature of its science return. This notably called for a complete redesign of the X-ray Integral Field Unit (X-IFU) cryogenic architecture towards a simpler active cooling chain. Passive cooling via successive radiative panels at spacecraft level is now used to provide a 50 K thermal environment to an X-IFU owned cryostat. 4.5 K cooling is achieved via a single remote active cryocooler unit, while a multi-stage Adiabatic Demagnetization Refrigerator ensures heat lift down to the 50 mK required by the detectors. Amidst these changes, the core concept of the readout chain remains robust, employing Transition Edge Sensor microcalorimeters and a SQUID-based Time-Division Multiplexing scheme. Noteworthy is the introduction of a slower pixel. This enables an increase in the multiplexing factor (from 34 to 48) without compromising the instrument energy resolution, hence keeping significant system margins to the new 4 eV resolution requirement. This allows reducing the number of channels by more than a factor two, and thus the resource demands on the system, while keeping a 4’ field of view (compared to 5’ before). Here, in this article, we will give an overview of this new architecture, before detailing its anticipated performances. Finally, we will present the new X-IFU schedule, with its short term focus on demonstration activities towards a mission adoption in early 2027.

Peille, Philippe [Centre National d’Etudes Spatial↗

Antihelium-3 sensitivity for the GRAMS experiment

The Gamma-Ray and AntiMatter Survey (GRAMS) is a next-generation balloon/satellite mission utilizing a Liquid Argon Time Projection Chamber (LArTPC) detector to measure both MeV gamma rays and antinuclei produced by dark matter annihilation or decay. The GRAMS can identify antihelium-3 events based on the measurements of X-rays and charged pions from the decay of the exotic atoms, Time of Flight (TOF), energy deposition, and stopping range. This paper shows the antihelium-3 sensitivity estimation using a GEANT4 Monte Carlo simulation. For the proposed long-duration balloon (LDB) flight program (35 days x 3 flights) and future satellite mission (2-year observation/10-year observation), the sensitivities become 1.47 × 10 −7 [m 2 s sr GeV/n] −1 and 1.55 × 10 −9 [m 2 s sr GeV/n] −1 /3.10 x 10 -10 [m 2 s sr GeV/n] −1 , respectively. The results indicate that GRAMS can extensively investigate various dark matter models through the antihelium-3 measurements.

Antihelium-3↗

Search for a heavy neutral lepton with the MAGNETO-𝜈 experiment using 241 Pu 𝛽 − decays

The MAGNETO-𝜈 experiment searches for keV-scale heavy neutral leptons (HNLs) through precise measurements of the 𝛽 − -decay spectrum of 241 Pu. We present spectra comprising a total of 194 million 𝛽 − decays recorded using decay energy spectrometry with metallic magnetic calorimeters, representing the most statistically precise measurement of 241 Pu 𝛽 − decay to date. The 𝛽-endpoint energy was determined using 𝛾 rays and x-rays from an external 133 Ba calibration source, yielding 𝑄 𝛽 = 22.273⁢ (33) ⁢keV. The measured spectrum shows no statistically significant deviation from the allowed 𝛽-decay model. From a subset of the high-statistics data, we set an upper limit on the mixing of an 11.5-keV HNL with the electron neutrino, |𝑈 𝑒⁢4 | 2 < 1.31 × 10 −3 at the 95% confidence level.

A ≥ 220↗

femto-PIXAR: a self-supervised neural network method for reconstructing femtosecond X-ray free electron laser pulses

X-ray Free Electron Lasers (X-FELs) operate in a wide range of lasing configurations for a broad variety of scientific applications at ultrafast time-scales such as structural biology, materials science, and atomic and molecular physics. Shot-by-shot characterization of the X-FEL pulses is crucial for analysis of many experiments as well as tuning the X-FEL performance. However, for the weak pulses found in advanced configurations, e.g. those needed for coherent, two-pulse studies of quantum materials, there is no current method for reliably resolving pulse profiles. Here we show that a physics-based U-net model can reconstruct the individual pulse power profiles for sub-picosecond pulse separation without the need for simulations. Using experimental data from weak X-FEL pulse pairs, we demonstrate we can learn the pulse characteristics on a shot-by-shot basis when conventional methods fail.

43 PARTICLE ACCELERATORS↗

Effect of Surface Passivation of CZTS Semiconductor Detector on Leakage Current

Cadmium Zinc Telluride Selenide (CdZnTeSe or CZTS)has shown high crystal quality for room-temperature gamma ray and X-ray detection applications compared to Cadmium Zinc Telluride (CdZnTe or CZT) [1,2]. Current applications of CZT include medical imaging, homeland security, and X-ray and gamma ray astronomy [3]. CZST has similar potential applications

Kangethe, Anthony [Morgan State Univ., Baltimore, ↗

The analysis of X-ray spectra.

Systematic analysis program for proportional counter X ray spectral observations of celestial objects, considering interaction between radiation field and detector

Garmire, G.↗